Magnecraft Struthers-Dunn PRODUCT INDEX DESCRIPTION CLASS TO CLASS CROSS REFERENCE GUIDE STOCKING DISTRIBUTORS, SALES REPRESENTATIVES & AGENTS SECTION 1 PAGE 1 & 2, DOCUMENT 100 PAGE DOCUMENT # INSIDE FRONT COVER 3 340 341 4-7 115 SELECTOR GUIDE Socket Compatible and General Purpose Relays - 1 to 30 Amperes W78 W67 A314/W250 284 W388/283 W388/283 W389 W389 W97 219 RSX-1800 W21 W88HP 1, 3, 5, 10 & 15 Amp, P.C. and Solder/Plug-in 3, 5 Amp, P.C. and Solder/Plug-in 10 Amp, Octal Plug-in 10 Amp, Solder Plug-in General Specifications 11 to 15 Amp, Solder Plug-in and Flange mount General Specifications & Ratings 30 Amps, Flange Mount 25 Amp, Plug-in and Side Stud mounting 10 Amp, Pin Base Plug-in 5 Amps, Pin Base Plug-in 30 Amps, Plug-in with Polarizing Pin. 10 AMP, Octal Plug-in, Hermetically Sealed 8 - 12 13 - 15 16 - 18 19, 20 21, 22 23 - 25 26 - 28 29, 30 31, 32 33, 34 35, 36 37 38 116 117 118 120 119 119 121 121 122 123 124 125 126 SECTION 2 SELECTOR GUIDE 39 - 43 342 Printed Circuit Board Relays - 1 to 30 Amperes 276 W90 W91 W9A W92 W7 W60 W178 W49 W76 W1330 & W1335 7 & 10 Amp, Subminiature 30 Amp Miniature 30 Amp, P.C. and Flange mount 30 Amp, P.C.and Flange mount 30 Amp, P.C.and Flange mount 2 Amp, Subminiature 2 AMP, Miniature 5 & 10 AMP, Miniature 3, 5 & 10 AMP, P.C.and Flange Mount 10 & 16 AMP, Miniature 5 Amp, Miniature 44 45, 46 47, 48 49, 50 51, 52 53, 54 55, 56 57, 58 59, 60 61, 62 63 109 102 103 104 105 106 107 112 113 114 108 SECTION 3 SELECTOR GUIDE 64 - 67 127 Application Data SIP, 0.5 Amp, 4 pin, SPST-NO or NC DIP, 0.5 Amp, 8 pin, SPST-NO Specifications DIP, 0.5 Amp, 8 pin, 1 & 2 pole-NO or NC DIP, 0.5 Amp, Dual Coil Latch, SPST-N.O. DIP. 0.5 - 1.0 Amp, SPDT, DPDT General Specifications Miniature, 0.5 Amp, 1 to 3 pole NO & Latching Miniature, 2 Amp, 1 & 2 pole NO Mercury Miniature, 0.25 Amp,SPDT, DPDT Miniature, 1.0 Amp, SPDT, DPDT Mercury Miniature, 0.5 Amp, up to 6 pole NO or 4PDT. Miniature, 0.5 Amp, with End Terminals Axial Lead, Shielded, 0.5 Amp, Open Style Metal Cover/Shield, Open Style Metal Cover/Shield Coxial R.F. switching 68, 69 70 71 72 73 74 74, 75 76 77 78 79 80 81, 82 83, 84 85, 86 87, 88 89 90 343 128 129 130 130 131 131 132 133 133 134 134 135 136 137 139 138 344 SELECTOR GUIDE 91 - 93 140 94 - 95 96 97, 98 99, 100 101 102, 103 104 - 107 108 108 345 141 142 143 144 145 146 147 147 Reed Relays for P.C. Board Applications - 3 VA to 100 VA REED W117 W107, W171, W172 W171 MRRDL W172 W101, W104, W131,W134,W193 W101, W131 W104 W134 W193 MR-Y MRR & RR RRN W102 W120 SECTION 4 Solid State Relays - 2 to 75 Amperes Solid State Relays W226, W230, W231 W226 W230 W231 W6 W6 W301T W6 PAGE 1 Application Data General Specifications Miniature ,7 Amp, P.C. or Push-on Terminals Miniature, 1.5 or 3 Amp. P.C Terminals Miniature, 4 Amp, Spade Terminals, Flange mount General Specifications 2.5 to 75 Amp. Screw Terminals Opto Isolator, axial Lead Embossed Safety Cover WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SECTION 5 DESCRIPTION PAGE DOCUMENT # SELECTOR GUIDE 109 - 112 148 Application Data Octal Style, 10 Amp Octal Style ,Programmable, 10 Amp, Miniature, 5 Amp Repeat Cycle, 10 Amps, Square base, 12Amp,Solder/plug-in or Flange 1 - 3 pole, 10 Amps, Solder/Plug-in, flange panel screw. Octal 1 -3 Pole, 10 Amp, Industrial Plug-in with Locking Clip. 10 Amps, Industrial Plug-in with Locking Clip. 10 Amps, Current Sensor, 10 Amps, Plug-in or Screw panel mount Voltage Sensor, 10 Amps, up to 400 HZ 1-3 Phase Voltage Sensor, 10-13 Amps, Solder/Plug-in or Octal 113, 114 115, 116 117 118 119 120 - 124 125, 126 127, 128 129 - 130 131 132 133 134, 135 149 151 150 152 153 154 346 347 348 157 158 159 160 SELECTOR GUIDE 136 - 139 161 140 - 146 147 148 149, 150 151, 152 153, 154 155, 156 157 158, 159 160 - 164 165 162 163 170 171 166 167 168 169 164 165 349 Time Delay Relays and Sensors Time Delay Relays W211 W211PROG W67 W222 W388 286/287 326, 327 236, 237 & 238 246, 247 W235 349 W236 SECTION 6 Relays and Contactors - 15 to 200 Amperes W199 425 W88UKD 415 275 575 101, 102, 103 214 MDR MDR 102, 103 Open Style, 30 Amp , SPDT Open Style, 30 Amp Power Relay up to 3 pole Miniature Open Style, 30 Amp, SPST-NO DM Open Style, 15 Amp, 1 & 2 Pole. Motor Reversing Contactor, 15 Amp, 3 Pole Motor Reversing Contactor, 30 Amp, 6 Pole Solenoid Style Contactor, SPST-DM, 50 to 200 Amps Ground Fault Interrupt (GFI), 20 Amp, DPDT General Specifications & Application Data Mercury Displacement relays 30 to 100 Amp Solinoid Style Lighting Contactor 100 & 200 Amps SECTION 7 SELECTOR GUIDE 166 - 168 172 Latching, Sequence and Stepper Relays Sequence & Latching W250ML W388ML/285 308 B255 W88L 311 C85 Application Data Octal Base, Magnetic Latching, 10 Amps Latching, 10 Amp, Solder/Plug-in Latching, 10 Amp, 4 Pole. Solder/Plug-in Mechanical Latch, 10 Amps, Pin base Plug-in Open or Enclosed Mechanical Latch,10 Amp Plug-in Sequence (Stepper), 5 Amp Open Style, Sequence (Stepper) 20 Amp 169 170 171, 172 173, 174 175, 176 177, 178 179 180 350 177 173 174 175 176 179 180 SECTION 8 SELECTOR GUIDE 181, 182 181 183 184 182 183 SELECTOR GUIDE 185, 186 184 112, 112PGF 67S 392 292 Low Power, 2 Amps, Pin Base Plug-in w/ locking clip Miniature Sensitive, 3 Amps, 2 - 6 Poles. Sensitive, Octal Plug-in, 5 Amps, 1 - 3 Poles Solder/plug-in, 5 Amps, 1 - 3 Poles 187, 188 189 190 191 185 351 186 187 SECTION 10 SELECTOR GUIDE 192 - 194 188 195 196 197, 198 199 200 201 202 203, 204 205 205 189 191 191 192 193 197 196 190 195 195 Hi- Voltage Relays - 2,500 to 10,000 Volts 158 102HV Open Style, 200 mA, 5000Vdc Encapsulated Reed, 10-30mA, up to 10kv SECTION 9 Sensitive Relays, Low Input Power Sockets and Accessories 70--464-1, 70-465-1 70-459-1, 70-461-1 70-378-1, 70-401-1, 70-379-1, 70-402-1, 70-463-1 70-124-1 & -2, 70-178-1 & -2 27390, 33377 70-475, 70-478 70-303-1 THRU 70-310-1 70-312 70-276 SECTION 11 CE Customer Service Staff Series A314/250, 8 & 11 Pin Octal, Panel/DIN mount CLASS 78 Panel/DIN mount Class 78, Chassis, P.C., Class 388/283 Style, Panel/DIN Mount Class 388/283 Style, Chassis Mount or P.C. Series 219 style, Panel mount, screw terminal Class 76 Style, Panel/DIN mount Class 67 chassis mount Class 97 Style, Chassis mount DIP Style, 14 Pin UTILIZATION CATAGORIES Utilization Categories Staff Directory 206 207 INSIDE BACK COVER WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 199 198 PAGE 2 Magnecraft Struthers-Dunn FAX ON DEMAND DIRECTORY ✭ STOCKING DISTRIBUTORS. ✭ FACTORY DIRECT FIELD SALES PROFESSIONALS. ✭ U.S. AND INTERNATIONAL AGENTS. PLEASE DIAL 800-891-2957 FOR AN UP-TO-DATE DIRECTORY FOR YOUR AREA. WHEN PROMPTED, PLEASE ENTER THE APPROPRIATE DOCUMENT NUMBER FROM THE MAP BELOW. DOCUMENT NUMBER OUTSIDE THE U.S. & CANADA: CANADA DOCUMENT NUMBER: 352 353 370 359 354 360 369 356 365 361 355 368 364 367 357 358 362 363 366 UNITED STATES DOCUMENT NUMBERS SHOWN INSIDE THE STATES. PAGE 3 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 S E C T I O N 1 1 SOCKET COMPATIBLE AND FLANGE MOUNTED GENERAL PURPOSE RELAYS 2 TO 30 AMPERES Page 4 Magnecraft Struthers-Dunn SOCKET COMPATIBLE RELAY SERIES A314/250 67 78 SEE SECTION 10 FOR MATING SOCKETS QUALIFIED POLYCARBONATE DUST COVER FEATURES ISO 9002 QS 9000 ISO 9002 QS 9000 POLYCARBONATE DUST COVER. POLYCARBONATE DUST COVER SOLDER/PLUG-IN OR PC BOARD MOUNTING. SOLDER/PLUG-IN OR PC BOARD 8 OR 11 PIN OCTAL PLUG-IN MOUNTING INDUSTRY STANDARD FOOTINDUSTRY STANDARD FOOTPRINTS. INDUSTRY STANDARD FOOTPRINTS UP TO 4 POLES WITH STANDARD OR PRINTS. INDICATOR LAMP AND PUSH BIFURCATED CONTACTS, INDICATOR UP TO 8 POLES WITH STANDARD BUTTON AVAILABLE. LAMP AND PUSH BUTTON, OR BIFURCATED CONTACTS. TOP FLANGE COVER , PANEL/DIN, PANEL/DIN STYLE SOCKETS CHASSIS OR P.C STYLE SOCKETS CHASSIS OR PC STYLE AVAILABLE. AVAILABLE. SOCKETS AVAILABLE. CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT CONTACT MATERIAL: RESISTANCE: SPDT, DPDT 15 &10 AMPS AT 120/240 VAC 4PDT 1, 3 & 5 AMPS AT 120/240 VAC SPDT TO 8PDT STANDARD CONTACTS 5 AMP BIFURCATED CONTACTS 3 AMP AT 120VAC/32VDC SILVER, GOLD PLATED - 1A SILVER, GOLD OVERLAY SILVER, GOLD FLASHED - 3A SILVER CADMIUM OXIDE - 5, 10 & 15A 50 MILLIOHMS (INITIAL) 50 & 100 MILLIOHMS MAX SPDT DPDT 3PDT 12 12 10 AMPS AMPS AMPS AT AT AT 120 VAC 120 VAC 240 VAC SILVER CADMIUM OXIDE, ( GOLD FLASHED) 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC 1500 V rms STRENGTH 1500 V rms 1500 V rms COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC) 6, 12, 24,120 & 240 VAC 6, 12, 24, 48 & 110 VDC 120 VAC 5, 12, 24, 48 &115 VDC 24, 120 & 240 VAC 12, & 24 VDC 1.2 VA 0.9 WATTS 2.5 VA 2 WATTS 2.75 VA 1.2 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: - 40˚ C to + 70˚ C 25 MILLISECONDS 25 MILLISECONDS AC- 50M, - DC-100M OPER'S. 200,000 OPERATIONS . H DIMENSIONS W L .858 X 1.10 X 1.40 APPROVALS PAGE NUMBER PAGE 5 C - 55˚ C to + 70˚ C - 55˚C to + 105˚C - 10˚ C to + 50˚ C (AC) - 10˚ C to + 60˚ C (DC) - 30˚ C to + 105˚ C 18 MILLISECONDS 8 MILLISECONDS 25 MILLISECONDS 20 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS 10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.20 X .735 X - C US PAGE 8 THRU 12 H W L 1.37 X 1.37 X 2.25 PAGE 13 THRU 15 US PAGE 16 THRU 18 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 Magnecraft Struthers-Dunn SOCKET COMPATIBLE & FLANGE MOUNT POLYCARBONATE 389 388 & 283 284 DUST COVER. POLYCARBONATE 97 QUALIFIED QUALIFIED ISO 9002 QS 9000 ISO 9002 QS 9000 DUST COVER. POLYCARBONATE FLANGED DUST COVER. 3/16" SOLDER/PLUG-IN, OR PC BOARD MOUNTING 3/16" SOLDER/PLUG-IN, FLANGE OR PC BOARD MOUNTING INDUSTRY STANDARD FOOTPRINT. INDUSTRY STANDARD FOOTPRINTS. 1/4" Q.C./SOLDER LUG TERMINALS FOR QUICK CONNECT. CAPABLE OF SWITCHING UP TO 30 AMPS. WIDE SELECTION OFPANEL/DIN, CHASSIS & P.C. STYLE SOCKETS INDUSTRY STANDARD FOOTPRINTS WIDE CHOICE OF OPTIONS. 15 AMP VERSIONS & TOP FLANGE COVERS AVAILABLE. TOP FLANGE COVER AVAILABLE. 4PDT SPDT MAX TOTAL LOAD 30 AMPS @ 120 VAC, 20 AMPS @ 240 VAC 10 AMPS PER POLE NOT TO EXCEED 30 AMPS 13 AMPS AT 240 VAC SILVER CADMIUM OXIDE, SILVER OR GOLD DIFFUSED 50 MILLIOHMS (INITIAL) 3PDT DPDT 12 AMPS AT 240 VAC 11 AMPS AT 240 VAC 388B STYLES RATED UP TO 10 AMPS AT 150 VDC. SILVER CADMIUM OXIDE, ( GOLD FLASHED) 50 MILLIOHMS (INITIAL) SPDT-NO-NC (DM-DB) SPDT, DPDT 25 AMPS @ 30 AMPS @ 300 VAC 300 VAC 3PDT 20 AMPS @ 150 VAC SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL) METAL DUST COVER 1/4" BRASS CONTACT TERMINALS DPDT-NO-NC (DM-DB) CONTACTS CHOICE OF MOUNTING MATING SOCKETS DPDT NO-NC (DM-DB) 25 AMPS @ 120 VAC/28VDC TUNG. LAMP 25A, 120VAC SILVER ALLOY 50 MILLIOHMS, (INITIAL) 2000 V rms 2200 V rms 6, 12, 24, 48, 120 & 240 VAC 6, 12, 24, 48, 115-125 VDC 24, 120 & 240 VAC 12, 24 & 120 VDC 24, 120 & 240 VAC 12, & 24 VDC 24, 120 & 240 VAC 12, 24 & 120 VDC 3.4 VA 1.9 WATTS 2.75 VA 1.2 WATTS 3.5 VA 1.44 WATTS 8 VA 3 WATTS - 30˚ C to + 50˚ C (AC) - 30˚ C to + 65˚ C (DC) - 30˚ C to + 100˚ C - 30˚ C to + 50˚ C (AC) - 30˚ C to + 65˚ C (DC) - 30˚ C to + 100˚ C 1500 V rms - 45˚ C to + 45˚ C (AC, COVR..) - 45˚ C to + 70˚ C (DC, COVR) - 45˚ C to + 85˚ C (DC, OPEN) 15 MILLISECONDS 10 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.50 X 1.93 X 1.87 24 MILLISECONDS 30 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS H L 1.40 X 1.53 X 1.90 C PAGE 19, 20 W US PAGE 21 THRU 25 20 MILLISECONDS 20 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.40 X 1.53 X 1.90 C 2000 V rms - 20˚ C to + 50˚ C 35 MILLISECONDS 35 MILLISECONDS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.56 X 1.56 X 2.06 US PAGE 26 THRU 30 PAGE 31, 32 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 6 Magnecraft Struthers-Dunn SOCKET COMPATIBLE RELAY SERIES 219 RSX-1800 POLYCARBONATE DUST COVER POLYCARBONATE DUST COVER 21 88HP SEE SECTION 10 FOR MATING SOCKETS FEATURES 12 OR 14 PIN STYLES ENCAPSULATED COIL WIDE CHOICE OF CONTACT COMBINATIONS. LARGE CHOICE OF OPTIONS MATING SOCKETS AVAILABLE CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: VARIOUS COMBINATIONS 10 AMPS @ 240 VAC/28 VDC 12 PIN STYLES PERFORMS BASIC FUNCTIONS OF AN ALARM POINT OPERATES FROM AN N.O. OR N.C. TROUBLE CONTACT POLYCARBONATE DUST COVER HERMETICALLY SEALED STEEL ENCLOSURE MEETS NEMA STD. TS 21992 APPROVED BY D.O.T 10 AMP AND 12 AMP CONTACTS INDUSTRY STANDARD FOOTPRINT 8 OR 11 PIN OCTAL BASE. MATING SOCKETS AVAILABLE 2 PAIR of DPDT or 3PDT 10 AMPS @ 120VAC, 28 VDC 20 AMPS @ 120/240 VAC, 28 VDC 20 AMPS, 120VAC TUNGSTEN (2 POLE) 12 AMPS @ 120VAC 8 AMPS @ 240 VAC (3 POLE) 10 AMPS @ 120VAC 6 AMPS @ 240 VAC SILVER CADMIUM OXIDE SILVER ALLOY SILVER CADMIUM OXIDE Available with Make Before Break contacts CONTACT MATERIAL: CONTACT RESISTANCE: SILVER CADMIUM OXIDE, GOLD DIFFUSED 50 MILLIOHMS (INITIAL) DPDT, 3PDT DPDT 50 MILLIOHMS (INITIAL) 100 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) 1500 V rms 1500 V rms INSULATION CHARACTERISTICS DIELECTRIC STRENGTH 1500 V rms 1500 V rms COIL DATA 6, 12, 24, 120 & 240 AC 6,12, 24(28),32,115(125)DC AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC) 5 VA 1.8 WATTS 6, 12, 24 & 120 VAC 6, 12, 24 & 110-125 VDC 120 VAC OPTIONAL VDC 120 VAC 12, 24 VDC 5 VA 1.8 WATTS 4 & 8 VA - 3.0 VA 1.5 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: - 10˚ C to + 60˚ C - 10˚ C to + 70˚ C - 40˚ C to + 84˚ C - 10˚C to + 50˚C (AC), - 10˚C to + 60˚C (DC), -30˚C to + 105˚C 25 MILLISECONDS 20 MILLISECONDS 25 MILLISECONDS 20 MILLISECONDS 25 MILLISECONDS 25 MILLISECONDS 25 MILLISECONDS 20 MILLISECONDS 20 MILLION OPERATIONS 100,000 OPERATIONS 20 MILLION OPERATIONS 500,000 OPERATIONS 5 MILLION OPERATIONS 250,000 OPERATIONS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L .2.62 X 1.468 X 2.593 H W L .2.47 X 1.85 X 2.84 H W L .2.62 X 1.468 X .2.593 DIMENSIONS APPROVALS C PAGE NUMBER PAGE 7 PAGE 33, 34 PAGE 35, 36 H W L 1.53 X 1.53X 2.03 US PAGE 37 PAGE 38 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY W78ACSX & CSX 4PDT, SOLDER/PLUG-IN 1, 3 OR 5 AMP W78APCX & PCX 4PDT, PRINTED CIRCUIT 1, 3 OR 5 AMP MANUFACTURED UNDER QUALITY SYSTEM ISO 9002 & QS 9000 W78ARCSX & RCSX SPDT, DPDT, SOLDER/PLUG-IN 10 OR 15 AMP Recognized Component mark for Canada and the United States. C US UL Recognized File No. E52197 SPECIFICATIONS CLASS 78 CONTACTS Contact Configurations: Contact Material: Contact Resistance: Contact Rating: 75% of Nominal Voltage or less for DC, 80% of nominal or less for AC. DC -10% min., AC - 30% min. 110% ±15% AC & DC Class "B" coil insulation system (130˚C per UL standard 1446) IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION SPDT, DPDT, 4PDT. 1 Amp Bifurcated Silver Gold plated. 3 AMP Silver Gold flashed 5 Amp, Silver Cadmium Oxide. 10 & 15 AMP, Silver Cadmium Oxide. 100 Milliohms Max.(3, 5, 10 & 15AMP) @ 6V, 1 AMP 50 Milliohms Max. ( 1 AMP) @ 6V, 0.1 AMP 4PDT- Bifurcated 1Amp @ 120/240 VAC 30VDC. 1/16HP (2.8A FLA), 120VAC. Pilot duty - 5A make, 1/2A break, 1 A continuous, 120 VAC 4PDT- 3 Amps @ 120/240 VAC, 30VDC, 1/10HP 120/240VAC, C300 pilot duty. 4PDT- 5 Amps @ 120/240 VAC, 30VDC, 1/6 HP 120/240VAC, C300 pilot duty DPDT -10 Amps @ 120/240VAC, 30VDC.1/3 HP,120VAC. 1/2HP 240VAC. SPDT -15 Amps @ 120/240VAC, 30VDC.1/3 HP 120VAC, 1/2 HP 240VAC. 25mS Max. @ Nominal Voltage. 25 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Coil to Frame: Across Open Contacts: Contact to Frame: Insulation Resistance: 1500 V rms 1000 V rms 1500 V rms 100 Megohms Min. @ 500 VDC. TEMPERATURE Ambient Temperature: -40˚C to + 70˚C @ Rated Operation MISCELLANEOUS Enclosure: Weight: COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE 2.3 Watts DC, 2.55 VA (60Hz) AC, approx. 5 minutes max. @ 40˚C Continuous TIMING Operate Time: Release Time: VIBRATION RESISTANCE Functional: , SHOCK RESISTANCE Mechanical Durability: Malfunction Durability: LIFE EXPECTANCY Mechanical (No Load): Electrical (rated Load): 78 W78ARPCX & RPCX SPDT, DPDT, SOLDER/PLUG-IN 10 OR 15 AMP * COIL Pull-in Voltage: Dropout: Max. Voltage: Coil Resistance: Coil Insulation: Maximum tolerable coil dissipation: Duty: CLASS NEW EPOXY SEALED VERSIONS AVAILABLE. CONSULT FACTORY. 10 to 55 Hz; 1mm ( Double Amplitude). Mechanical Durability, 1000 m/s2 (approx.100 G ). Malfunction Durability, 200 m/s2 (approx. 20 G ). 10,000,000 Operations (AC & DC). 200,000 Operations Min. (at rated Resistive load). Clear Polycarbonate Dust Cover, Molded. SPDT & DPDT 1.41 oz, (Approx. 40 g) , 4PDT 2.47 oz. (Approx. 70 g). * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 8 CLASS ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY 78 OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) WIRING DIAGRAM FOR 4PDT RELAY Optional FLANGED COVER available on special order as Non-Stock. .138Typ. (.3.51) .020 Typ. (.51) 1 2 3 4 5 6 7 8 10 11 12 9 1.33 (33.8) 14 13 1.10 Max. (27.9) 1.72 Max. (43.7) Observe polarity when L.E.D. Indicator is installed across coil. ( DC Styles Typ.) (+) 14 (-) 13 OR DC STYLES AC STYLES ALL INDICATOR LAMP STYLE RELAYS HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL. .079 (2.0) 1.40 Max. P.C. Style (35.56) .020 (.51) .140 (3.56) .51 (12.95) .858 Max. (21.8) P.C. STYLE Q.C. STYLE 1.40 Max. (35.56) 1.65 Max. (41.91) .250 max (6.35) .51 (12.95) .100 (2.54) .17 (4.32) .17 (4.32) .16 (4.06) .040 Max. (1.02) .50 (12.7) .25 (6.35) ALL 4 POLE RELAYS HAVE OPPOSITE POLARITY ARC BARRIERS AS A STANDARD FEATURE. ARC BARRIERS PROVIDE GREATER VOLTAGE PROTECTION BETWEEN ADJACENT POLES .25 (6.35) .15 (3.81) ARC BARRIE R .05 dia. (1.27) 14 holes P.C MOUNTING HOLE LAYOUT ( BOTTOM VIEW ) NEW! 1 AMP 4PDT CONTACTS BIFURCATED 1 AMP Coil measured @ 25˚C Nominal Nominal Nominal Power Resistance Input (Approx.) (Ohms) Voltage RELAYS CROSS REFERENCE TO POTTER & BRUMFIELD IDEC OMRON AC OPERATED COIL - SOLDER/PLUG-IN STYLE. W78ATCSX-2 W78ATCSX-3 W78ATCSX-5 W78ATCSX-6 12 VAC 24VAC 120 VAC 240 VAC 46 180 4430 15,700 1.2VA 1.2VA 1.2VA 1.2VA KHAU17A96-12 KHAU17A96-24 KHAU17A96-120 KHAU17A96-240 RY42S-U-AC12V RY42S-U-AC24V RY42S-U-AC110/120V RY42S-U-AC220/240V MY4Z-UA-AC12 MY4Z-UA-AC24 MY4Z-UA-AC120 MY4Z-UA-AC240 KHAU17A96N-120 RY42S-UL-AC24V RY42S-UL-AC110/120V RY42S-UL-AC220/240V MY4ZN-UA-AC12 MY4ZN-UA-AC24 MY4ZN-UA-AC240 KHAU17D96-6 KHAU17D96-12 KHAU17D96-24 KHAU17D96-110 RY42S-U-DC6V RY42S-U-DC12V RY42S-U-DC24V RY42S-U-DC100/110V MY4Z-UA-DC6 MY4Z-UA-DC12 MY4Z-UA-DC24 MY4Z-UA-DC110 AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP. W78ANTCSX-4 W78ANTCSX-5 W78ANTCSX-7 24 VAC 120VAC 240 VAC 180 4430 15,700 1.2VA 1.2VA 1.2VA DC OPERATED COIL - SOLDER/PLUG-IN STYLE W78TCSX-1 W78TCSX-2 W78TCSX-3 W78TCSX-5 6 VDC 12 VDC 24VDC 110 VDC 40 160 650 11,000 0.9W 0.9W 0.9W 1.1W DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP 24 VDC 0.9W KHAU17D96L-24 650 RY42S-UL-DC24V PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION. W78NTCSX-5 MY4ZN-UA-DC24 SEE SECTION 10 FOR MATING SOCKETS PAGE 9 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY 4PDT CONTACTS 3 AMP 78 RELAYS - 3 AMP Coil measured @ 25˚C Nominal Nominal Nominal Power Resistance Input (Approx.) (Ohms) Voltage CROSS REFERENCE TO POTTER & BRUMFIELD OMRON IDEC AC OPERATED COIL - SOLDER/PLUG-IN STYLE. W78ACSX-2 W78ACSX-3 W78ACSX-5 W78ACSX-6 12 VAC 24VAC 120 VAC 240 VAC 46 180 4430 15,700 1.2VA 1.2VA 1.2VA 1.2VA RY4S-U-AC12V RY4S-U-AC24V RY4S-U-AC110/120V RY4S-U-AC220/240V MY4-UA-AC12 MY4-UA-AC24 MY4-UA-AC120 MY4-UA-AC240 KHAU17A91N-120 KHAU17A91N-240 RY4S-UL-AC24V RY4S-UL-AC110/120V RY4S-UL-AC220/240V MY4N-UA-AC12 MY4N-UA-AC24 MY4N-UA-AC240 KHAU17D91-6 KHAU17D91-12 KHAU17D91-24 KHAU17D91-110 RY4S-U-DC6V RY4S-U-DC12V RY4S-U-DC24V RY4S-U-DC100/110V MY4-UA-DC6 MY4-UA-DC12 MY4-UA-DC24 MY4-UA-DC110 KHAU17D91N-24 RY4S-UL-DC24V MY4N-UA-DC24 KHAE17A11-24 KHAE17A11-120 RY4V-U-AC24V RY4V-U-AC110/120V MY4-02-UA-AC24 MY4-02-UA-AC120 KHAE17D11-12 KHAE17D11-24 KHAE17D11-110 RY4V-U-DC12V RY4V-U-DC24V RY4V-U-DC100/110V MY4-02-UA-DC12 MY4-02-UA-DC24 MY4-02-UA-DC110 KHAU17A91-12 KHAU17A91-24 KHAU17A91-120 KHAU17A91-240 AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP. W78ANCSX-24 W78ANCSX-25 W78ANCSX-26 24 VAC 120VAC 240 VAC 180 4430 15,700 1.2VA 1.2VA 1.2VA DC OPERATED COIL - SOLDER/PLUG-IN STYLE 6 VDC 12 VDC 24VDC 110 VDC W78CSX-1 W78CSX-2 W78CSX-3 W78CSX-6 40 160 650 11,000 0.9W 0.9W 0.9W 1.1W DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP W78NCSX-23 24 VDC 650 0.9W AC OPERATED - PRINTED CIRCUIT STYLE W78APCX-3 W78APCX-5 24 VAC 12 0 VAC 180 4430 1.2VA 1.2VA DC OPERATED - PRINTED CIRCUIT STYLE W78PCX-2 W78PCX-3 W78PCX-6 12 VDC 24 VDC 110 VDC 160 650 11,000 0.9W 0.9W 1.1W 4PDT CONTACTS 5 AMP RELAYS - 5 AMP Coil measured @ 25˚C Nominal Nominal Nominal Power Resistance Input (Approx.) (Ohms) Voltage CROSS REFERENCE TO POTTER & BRUMFIELD IDEC AC OPERATED COIL - SOLDER/PLUG-IN STYLE. W78KACSX-15 W78KACSX-17 W78KACSX-18 12 VAC 24VAC 120 VAC 240 VAC 46 180 4430 15,700 1.2VA 1.2VA 1.2VA 1.2VA KHAU17A21-12 KHAU17A21-24 KHAU17A21-120 KHAU17A21-240 RY4S-U-AC12V RY4S-U-AC24V RY4S-U-AC110/120V RY4S-U-AC220/240V KHAU17D21-12 KHAU17D21-24 RY4S-U-DC12V RY4S-U-DC24V DC OPERATED COIL - SOLDER/PLUG-IN STYLE W78KCSX-12 W78KCSX-13 12 VDC 24VDC 160 650 0.9W 0.9W PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION. SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 10 CLASS ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY 78 OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) DOUBLE POLE DOUBLE THROW Optional FLANGED COVER available on special order as Non-Stock. .138Typ. (.3.51) .020 Typ. (.31) 1.375 Max. (34.92) 5 6 (+) 8 (-) 7 8 DC STYLES ALL INDICATOR LAMP STYLE RELAYS HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL. .187 Typ. (4.75) .858 Max. (21.8) .560 (14.2) .39 (9.91) .16 (4.06) P.C. STYLE Q.C. STYLE 4 AC STYLES 1.72 Max. (43.7) .080 Typ. (2.03) .040 (1.02) 1.375 Max. P.C. Style (34.92) .18 (4.57) .12 Dia. (3.04 ) Typ. 3 OR 1.10 Max. (27.9) .079 (2.0) 2 7 1.33 (33.8) Observe polarity when L.E.D. Indicator is installed across coil. ( DC Styles Typ.) 1 .18 (4.57) .52 (13.21) .28 (7.11) .291 Max. (7.39) .13 (3.30) 0.10 dia.(2.54) 8 holes P.C MOUNTING HOLE LAYOUT ( BOTTOM VIEW ) DPDT RELAYS - 10 AMPS DPDT, 10 AMP STANDARD COVER Coil measured @ 25˚C Nominal Nominal TOP FLANGE Input Nominal Resistance Power COVER (Approx.) Voltage (Ohms) CROSS REFERENCE TO* POTTER & BRUMFIELD IDEC OMRON K10P11A15-6 K10P11A15-24 K10P11A15-120 K10P11A15-240 RH2B-U-AC6V RH2B-U-AC24V RH2B-U-AC110/120V RH2B-U-AC220/240V LY2-UA-AC6 LY2-UA-AC24 LY2-UA-AC120 LY2-UA-AC240 AC OPERATED COIL - SOLDER/PLUG-IN STYLE. W78ARCSX-7 W78ARCSX-9 W78ARCSX-11 W78ARCSX-12 78ARCSX-1 78ARCSX-3 78ARCSX-5 78ARCSX-6 6 VAC 24VAC 120 VAC 240 VAC 12.2 180 4430 15,700 1. VA 1.2VA 1.2VA 1.2VA AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP. W78ARNCSX-6 W78ARNCSX-5 W78ARNCSX-7 24 VAC 120VAC 240 VAC 180 4430 15,700 1.2VA 1.2VA 1.2VA RH2B-UL-AC24V LY2N-UA-AC24 K10L11A15-120 RH2B-UL-AC110/120V LY2N-UA-AC120 RH2B-UL-AC220/240V LY2N-UA-AC240 DC OPERATED COIL - SOLDER/PLUG-IN STYLE W78RCSX-6 W78RCSX-7 W78RCSX-8 W78RCSX-9 W78RCSX-10 78RCSX-1 78RCSX-2 78RCSX-3 78RCSX-4 78RCSX-5 6 VDC 12 VDC 24VDC 48 VDC 110 VDC 0.9W 0.9W 0.9W 0.9W 1.1W 40 160 650 2,600 11,000 K10P11D15-6 K10P11D15-12 K10P11D15-24 K10P11D15-48 K10P11D15-110 RH2B-U-DC6V RH2B-U-DC12V RH2B-U-DC24V RH2B-U-DC48V RH2B-UL-DC100/110V LY2-UA-DC6 LY2-UA-DC12 LY2-UA-DC24 LY2-UA-DC48 LY2-UA-DC110 RH2B-UL-DC24V LY2N-UA-DC24 DC OPERATED COIL -SOLDER/PLUG-IN WITH INDICATOR LAMP W78RNCSX-6 24 VDC 0.9W 650 AC OPERATED COIL -P.C. TERMINAL STYLE W78ARPCX-5 W78ARPCX-6 120 VAC 240 VAC 4430 15,700 1.2VA 1.2VA K10P11A55-120 RH2V2-U-AC110/120V K10P11A55-240 RH2V2-U-AC220/240V LY2-0-UA-AC120 LY2-0-UA-AC240 DC OPERATED COIL -P.C. TERMINAL STYLE W78RPCX-1 W78RPCX-2 W78RPCX-3 6VDC 12 VDC 24 VDC 40 160 650 0.9W 0.9W 0.9W K10P11D55-6 K10P11D55-12 K10P11D55-24 RH2V2-U-DC6V RH2V2-U-DC12V RH2V2-U-DC24V PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION. LY2-0-UA-DC6 LY2-0-UA-DC12 LY2-0-UA-DC24 * Applies to Standard Cover SEE SECTION 10 FOR MATING SOCKETS PAGE 11 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY 78 OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) SINGLE POLE DOUBLE THROW Optional FLANGED COVER available on special order as Non-Stock. 1 2 3 4 5 7 6 Observe polarity when L.E.D. Indicator is installed across coil. (DC Styles Typ.) .138Typ. (.3.51) .020 Typ. (.31) 1.33 (33.8) (+) 8 (-) 7 8 OR DC STYLES AC STYLES 1.10 Max. (27.9) 1.72 Max. (43.7) ALL INDICATOR LAMP STYLE RELAYS HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL. .187 Typ. (4.75) .080 Typ. (2.03) .040 (1.02) 1.375 Max. P.C. Style (34.92) .18 (4.57) .12 Dia. (3.04 ) Typ. .079 (2.0) .39 (9.91) .16 (4.06) P.C. STYLE Q.C. STYLE 1.375 Max. (34.92) .560 (14.2) .858 Max. (21.8) .18 (4.57) .52 (13.21) .28 (7.11) .291 Max. (7.39) .13 (3.30) 0.10 dia.(2.54) 8 holes P.C MOUNTING HOLE LAYOUT ( BOTTOM VIEW ) SPDT RELAYS - 15 AMPS Coil measured @ 25˚C SPDT, 15 AMP STANDARD COVER TOP FLANGE COVER Nominal Input Voltage Nominal Resistance (Ohms) CROSS REFERENCE TO * Nominal Power (Approx.) OMRON AC OPERATED COIL - SOLDER/PLUG-IN STYLE. W78ARCSX-108 W78ARCSX-109 W78ARCSX-111 W78ARCSX-112 78ARCSX-33 78ARCSX-34 78ARCSX-36 78ARCSX-37 12 VAC 24VAC 120 VAC 240 VAC 46 180 4430 15,700 1.2VA 1.2VA 1.2VA 1.2VA LY1-UA-AC12 LY1-UA-AC24 LY1-UA-AC120 LY1-UA-AC240 AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP 24 VAC 120VAC 240 VAC W78ARNCSX-8 W78ARNCSX-9 W78ARNCSX-10 180 4430 15,700 1.2VA 1.2VA 1.2VA LY1N-UA-AC24 LY1N-UA-AC120 LY1N-UA-AC240 DC OPERATED COIL - SOLDER/PLUG-IN STYLE W78RCSX-96 W78RCSX-97 W78RCSX-98 W78RCSX-100 78RCSX-31 78RCSX-32 78RCSX-33 78RCSX-35 6 VDC 12 VDC 24VDC 110 VDC 40 160 650 11,000 0.9W 0.9W 0.9W 1.1W LY1-UA-DC6 LY1-UA-DC12 LY1-UA-DC24 LY1-UA-DC110 DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP W78RNCSX-10 24 VDC 650 0.9W LY1N-UA-DC24 AC OPERATED COIL -P.C. TERMINAL STYLE W78ARPCX-81 W78ARPCX-82 W78ARPCX-84 12 VAC 24 VAC 120 VAC 46 180 4430 1.2VA 1.2VA 1.2VA LY1-0-UA-AC12 LY1-0-UA-AC24 LY1-0-UA-AC120 DC OPERATED COIL -P.C. TERMINAL STYLE W78RPCX-79 W78RPCX-83 W78RPCX-85 12 VDC 24 VDC 110 VDC 160 650 11,000 0.9W 0.9W 1.1W LY1-0-UA-DC12 LY1-0-UA-DC24 LY1-0-UA-DC110 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION. * Applies to Standard Cover SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 12 CLASS MINIATURE ENCLOSED INDUSTRIAL RELAY 67 CONTACT MATERIAL: SILVER GOLD OVERLAY RATED 3 or 5 AMPS @ 32VDC/120VAC WIRING DIAGRAM The Class 67 Relays have combination solder/plug-in terminals with a 3-48UNC stud or printed circuit terminals. 8PDT 6PDT UL RECOGNIZED FILE NO. E52197 4PDT DPDT Standard Class 67 miniature industrial relays are designed for applications requiringDPDT to 8PDT contacts where space and weight are of prime importance. Shatter resistant, see-thru plastic covers are utilized to protect against dust, tampering and electrical shock. The 67T models have Bifurcated Contacts and are designed for low level switching applications. SEE SECTION 10 FOR MATING SOCKETS. 4 TYPICAL CONTACT LIFE EXPECTANCY FOR SWITCHING RESISTIVE LOADS @ 25˚C Load Current 5.0A 5.0A 2.0A 1.0A 0.5A 0.1A 0.1A 50mA 30mA 1mA 10A Load Voltage 28 VDC 120VAC 28VDC/120VAC 28VDC/120VAC 28VDC/120VAC 28VDC/120VAC 6 VDC 6 VDC 6 VDC 6 VDC 10mVDC Number of Operations Standard adjustment 5 X 104 5 X 104 1.5 X 106 1.2 X 107 5 X 107 5 X 107 5 X 107 1 2 3 Bottom View CLASS 67 TYPICAL TIMING VALUES POLES DPDT 4PDT 6PDT 8PDT OPERATE TIME 012 .014 .016 .018 RELEASE TIME .008 .008 .008 .008 Measured at Nominal Voltage @ 25˚C SPECIFICATIONS CLASS 67 COIL Pickup voltage: Dropout voltage: Coil resistance: Maximum coil dissipation: Coil Temperature rise: Maximum coil temperature: CONTACTS Contact material: Contact resistance: CAPACITANCE Between contacts: Contact to coil: Coil to frame: PAGE 13 80% of nominal voltage or less. 10% of nominal or more. ± 10% measured @ 25˚C 2.2 watts 30˚C per watt 105˚C Silver, Gold overlay 50 milliohms max. initial 2 pf, typ. 2 pf, typ. 30 pf, typ. DIELECTRIC STRENGTH Contact to coil: Across open contacts: Coil to frame: Contacts to frame: Insulation resistance: 1500 V rms 500 V rms 1000 V rms 1500 V rms 1000 megohms @ 25˚C & 50% R.H. TEMPERATURE Operating: Storage: -55˚C to + 70˚C -55˚C to +105˚C MISCELLANEOUS Solder-bath temperature: +525˚F (260˚C) 10 seconds max. Enclosure Material: Polycarbonate see thru plastic cover. Operating Position: Any Weight: 0.77 to 1.4 oz. (22 to 40 grams) OPTIONS: Other options such as other coil voltages, sensitivities, contact arrangements and epoxy sealing are available on special order. Consult Factory for special requirements. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS MINIATURE ENCLOSED INDUSTRIAL RELAY 67 OUTLINE DIMENSIONS Dimensions shown in INCHES and (MILLIMETERS) DIMENSIONS Tolerances ± .010 Inches "A" CONTACT CONFIGURATION "A" DPDT .978 (24.8) 4PDT 1.156 (29.4) 6PDT 1.374 (34.9) 8PDT 1.592 (40.4)) 1.20 Max. (30.3) .094 (2.3) .170 (4.3) .200 Max. (5.1) 3-48UNC-2A Thd. DIM. Elongated Hole .100 x .040 ( 2 x .1) All Contact Terminals are .010 Thick all coil terminals are .018 Thick. "A" P.C RELAY PIN LAYOUT SUGGESTED PRINTED CIRCUIT BOARD LAYOUT FOR RELAYS WITH PRINTED CIRCUIT TERMINALS 1.20 Max. (30.3) .400 (10.2) .200 (5.1) .053 (1.35) .630 .740 (18.8) .530 (16.0) (13. 4) .210 (5.3) .110 (2.7) .060 ±.002 Dia. (1.5) ± (.05) .320 (8.1) COIL TERMINALS .032 (0.80) .735 Max. (18.7) .135 (3.42) .420 (10.6) .550 (13..97) .098 (2.48) Typ. .225 (5.7) .450 (11.43) .165 (4.19) Typ. .040 (1.0) Typ. CONTACT TERMINALS All Contact Terminals are .010 Thick. All Coil Terminals are .018 Thick. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 14 CLASS MINIATURE ENCLOSED INDUSTRIAL RELAY 67 DC OPERATED - SOLDER TERMINAL or PLUG-IN STYLE COIL STANDARD CONTACTS PART NUMBERS W67RCSX-1 W67RCSX-2 W67RCSX-3 W67RCSX-4 W67RCSX-5 W67RCSX-6 W67RCSX-7 W67RCSX-8 W67RCSX-9 W67RCSX-10 W67RCSX-12 W67RCSX-13 W67RCSX-17 W67RCSX-18 Measured @ 25˚C CONTACT RATING NOMINAL INPUT VOLTAGE NOMINAL RESISTANCE (OHMS) 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 12 24 48 115 5 12 24 48 115 12 24 12 24 52 185 700 2500 15,000 52 185 700 2500 15,000 90 430 72 350 NOMINAL POWER (WATTS) CONTACT CONFIGURATION 1/2W 3/4W 1W 1W 1W 1/2W 3/4W 1W 1W 1W 1.5W 1.5W 2W 2W CROSS REFERENCE TO POTTER & BRUMFIELD DPDT DPDT DPDT DPDT DPDT 4PDT 4PDT 4PDT 4PDT 4PDT 6PDT 6PDT 8PDT 8PDT R10E1(X or Y)2-V28 R10E1(X or Y)2-V185 R10E1(X or Y)2-V700 R10E1(X or Y)2-V2.5K R10E1(X or Y2-V15.0K R10E1(X or Y)4-V28 R10E1(X or Y)4-V185 R10E1(X or Y)4-V700 R10E1(X or Y)4-V2.5K R10E1(X or Y)4-V15.0K R10E1(X or Y)6-V185 R10E1(X or Y)6-V700 R10E1(X or Y)8-V185 R10E1(X or Y)8-V700 DPDT DPDT 4PDT 4PDT 6PDT 6PDT 8PDT 8PDT R10E1(P or Z)2-V185 R10E1(P or Z)2-V700 R10E1(P or Z)4-V185 R10E1(P or Z)4-V700 R10E1(P or Z)6V185 R10E1(P or Z)6-V700 R10E1(P or Z)8-V185 R10E1(P or Z)8-V700 DC OPERATED - BIFURCATED CONTACTS - FOR LOW LEVEL SWITCHING APPLICATIONS W67TRCSX-2 W67TRCSX-3 W67TRCSX-7 W67TRCSX-8 W67TRCSX-12 W67TRCSX-13 W67TRCSX-17 W67TRCSX-18 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 185 700 185 700 90 430 72 350 12 24 12 24 12 24 12 24 3/4W 1W 3/4W 1W 1.5W 1.5W 2W 2W DC OPERATED - PRINTED CIRCUIT STYLE STANDARD CONTACTS PART NUMBERS W67RPCX-2 W67RPCX-3 W67RPCX-7 W67RPCX-8 W67RPCX-12 W67RPCX-13 CONTACT RATING 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS 5 AMPS COIL NOMINAL INPUT VOLTAGE 12 VDC 24 VDC 12 VDC 24 VDC 12 VDC 24 VDC Measured @ 25˚C NOMINAL NOMINAL POWER RESISTANCE (WATTS) (OHMS) 185 1W 700 1W 185 1W 700 1W 90 1.5W 430 1.5W CONTACT CONFIGURATION DPDT DPDT 4PDT 4PDT 6PDT 6PDT CLASS 67 - AC OPERATED RELAYS - SOLDER TERMINAL or PLUG-IN STYLE 50/60 Hz STANDARD CONTACTS COIL Measured @ 25˚C CONTACT NOMINAL NOMINAL NOMINAL CONFIGUCONTACT PART NUMBERS POWER INPUT RESISTANCE RATION RATING (WATTS) VOLTAGE (OHMS) W67ARCSX-5 120 VAC 1.5VA 5 AMPS DPDT W67ARCSX-10 120 VAC 5 AMPS 2.5VA 4PDT W67ARCSX-15 120 VAC 2.5VA 5 AMPS 6PDT CROSS REFERENCE TO POTTER & BRUMFIELD R10E2(X or Y)2-V185 R10E2(X or Y)2-V700 R10E2(X or Y)4-V185 R10E2(X or Y)4-V700 R10E2(X or Y)6-V185 R10E2(X or Y)6-V700 CROSS REFERENCE TO POTTER & BRUMFIELD R10E1(X or Y)2-120V R10E1(X or Y)4-120V R10E1(X or Y)6-120V Part numbers shown also available thru Stocking Distribution. STANDARD CONTACTS BIFURCATED CONTACTS ( LOW LEVEL APPLICATIONS) (5 AMP CROSS BAR) SEE SECTION 10 FOR MATING SOCKETS PAGE 15 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY CLASS A314 & 250 FEATURES Plug-in, 8 or 11 pin "Octal Style Base" with see thru plastic dust cover. Standard SPDT, DPDT or 3PDT contact arrangements. Other contact arrangements available on special order. Dielectric Strength to 1500 Vrms. 8 or 11 pin octal style plug-in are standard and Interchangeable with other general purpose relays of this type. Available with combinations of Indicator lamps, push to test button and Blow-out Magnets for DC switching applications. MANUFACTURED UNDER QUALITY SYSTEM ISO 9002 & QS 9000 Recognized Component mark for Canada and the United States. C US WIRING DIAGRAM UL Recognized File No. E43641 (-) VIEWED FROM PIN END 3PDT (-) (+) DPDT (+) SPDT ALL INDICATOR LAMP STYLE RELAY HAVE AN ADDITIONAL LAMP CIRCUIT INSTALLED ACROSS COIL. OBSERVE COIL POLARITY WHEN L.E.D. INDICATOR IS INSTALLED ACROSS COIL (DC STYLES TYP.). OUTLINE DIMENSIONS Dimensions are shown in Inch and (Millimeter). Artwork marking side 2.81 max. (71.4) 1.37 (34.79) 2.25 max. (57.2) 4 5 3 6 1.37 (34.79) 7 2 1 8 CONTACT RATINGS TABLE POLES 120 VAC 240 VAC SPDT 12 AMP 1/3 HP 12 AMP 1/2 HP 10 AMP 12 AMP 1/3 HP 10 AMP 1/2 HP 10 AMP 10 AMP 1/3 HP 10 AMP 1/2 HP 10 AMP DPDT 3PDT 28 VDC SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 16 CLASS OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY A314 & 250 CLASS A314 & 250 8 OR 11 PIN OCTAL PLUG-IN WITH SEE THRU DUST COVER. Enclosure is a clear high impact plastic (polycarbonate) dust cover that is screwed to the base to protect against dust, damage and tampering. Recognized Component mark for Canada and the United States. C US UL Recognized File No. E43641 SPECIFICATIONS SERIES A314 & 250 RELAYS COIL Pull-in voltage: 80% of nominal voltage or less. for DC coils 85% of nominal voltage or less for AC coils. 10% of nominal voltage or more. ± 10 % measured @ 25 ˚C 125 milliwatts per pole 1.2 Watts for DC coils, 2 VA-2.75VA for AC coils Capability of DC coils 3.0 Watts max. Continuous Drop-out: Coil resistance: Minimum sensitivity: Nominal power: Maximum coil dissipation: Duty: CONTACTS Contact material: 3/16" silver cadmium oxide, gold flashed Std. Gold Diffused also available. 50 milliohms maximum initial resistance at rated current 12 V @ 100 Milliamps Contact resistance: Minimum Load: TIMING Operate time: Release time: 15 mS or less at nominal voltage. 10 mS or less at nominal Voltage. DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole: Contacts to frame: Insulation resistance: 1500 V rms 500 V rms 1500 V rms 1500 V rms 1,000 Megohms min. @ 500 VDC TEMPERATURE Ambient Temperature (Operating): Non operating storage: -45˚C to +55˚C (AC), -45˚C to +70˚C (DC) -45˚C to +105˚C SHOCK RESISTANCE Operating: Non operating: 5 G's, 20 G's VIBRATION RESISTANCE Operating: 5 G's, 10 Hz to 55 Hz MISCELLANEOUS Enclosure: Insulation material: Operating Position: Terminals: Weight: Plastic dust cover with octal plug. Molded plastic Any 8 or 11 pin octal plug-in 3 1/2 ozs. 99.2 g approx. SEE SECTION 10 FOR MATING SOCKETS PAGE 17 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY A314 & 250 Struthers-Dunn RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW DUAL MARKED PART NUMBERS SERIES A314 CLASS 250CP CONTACT CONFIGURATION AC OPERATED A314XAX48P-24A A314XAX48P-120A A314XBX48P-24A A314XBX48P-120A A314XBX48P-240A W250ACPX-3 W250ACPX-4 W250ACPX-8 W250ACPX-9 W250ACPX-10 SPDT SPDT DPDT DPDT DPDT A314XCX48P-24A A314XCX48P-120A A314XCX48P-240A W250ACPX-13 W250ACPX-14 W250ACPX-15 3PDT 3PDT 3PDT Struthers-Dunn CROSS REFERENCE TO POTTER & IDEC BRUMFIELD COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL RESISINPUT POWER TANCE VOLTAGE 24 VAC 120VAC 24 VAC 120VAC 240 VAC, 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz - 2.0VA 2.0VA 2.75VA 2.75VA - 2.75VA 2.75VA 2.75VA - 2.75VA * KRPA5AG (or GF) -24 KRPA5AG (or GF) -120 KRPA11AG (or GF) -24 RR2P-U-AC24V KRPA11AG (or GF) -120 RR2P-U-AC120V KRPA11AG (or GF) -240 RR2P-U-AC240V KRPA14AG (or GF) -24 RR3PA-U-AC24V KRPA14AG (or GF) -120 RR3PA-U-AC120V KRPA14AG (or GF) -240 RR3PA-U-AC240V AC OPERATED WITH INDICATOR LAMP A314XBX48PL-24A W250ANCPX-26 A314XBX48PL-120A W250ANCPX-27 A314XBX48PL-240A W250ANCPX-28 DPDT DPDT DPDT A314XCX48PL-24A W250ANCPX-29 A314XCX48PL-120A W250ANCPX-30 A314XCX48PL-24OA W250ANCPX-31 3PDT 3PDT 3PDT 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 2.0VA 2.0VA 2.75VA KRPA11AN (or NF) -24 RR2P-UL-AC24V KRPA11AN (or NF) -120 RR2P-UL-AC120V KRPA11AN (or NF) -240 RR2P-UL-AC240V 2.0VA 2.0VA 2.75VA KRPA14AN (or NF) -24 RR3PA-UL-AC24V KRPA14AN (or NF) -120 RR3PA-UL-AC120V KRPA14AN (or NF) -240 RR3PA-UL-AC240V DC OPERATED A314XAX48P-12D A314XAX48P-24D A314XBX48P-12D A314XBX48P-24D A314XCX48P-12D A314XCX48P-24D W250CPX-2 W250CPX-3 W250CPX-6 W250CPX-7 W250CPX-10 W250CPX-11 SPDT SPDT DPDT DPDT 3PDT 3PDT 12 VDC 24 VDC 12VDC 24 VDC 12 VDC 24 VDC 120 Ω 472 Ω 120 Ω 472 Ω 120 Ω 472 Ω 1.2W 1.2W 1.2W 1.2W 1.2W 1.2W KRPA5DG (or GF) -12 KRPA5DG (or GF) -24 KRPA11DG (or GF) -12 KRPA11DG (or GF) -24 KRPA14DG (or GF) -12 KRPA14DG (or GF) -24 RR2P-U-DC12V RR2P-U-DC24V RR3PA-U-DC12V RR3PA-U-DC24V 24 VDC 24 VDC 472 Ω 472 Ω 1.2 W 1.2 W KRPA11DN (or NF) -24 KRPA14DN (or NF) -24 RR2P-UL-DC24V RR3PA-UL-DC24V DC OPERATED WITH INDICATOR LAMP A314XBX48PL-24D A314XCX48PL-24D W250NCPX-20 W250NCPX-21 DPDT 3PDT *F = GOLD FLASHED PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION CONTACT RATINGS WITH BLOW-OUT MAGNET POLES 120 VAC 240 VAC DPDT 12 AMP 1/3 HP 10 AMP 1/2 HP 30 VDC 10 AMP 150 VDC 3 AMP RELAYS FOR DC SWITCHING PART NUMBERS CONTACT NO. OF PINS CONFIGUOCTAL RATION STYLE - COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL INPUT RESISTANCE POWER VOLTAGE (OHMS) AC OPERATED WITH BLOW-OUT MAGNET A314XBX48P69-24A A314XBX48P69-120A DPDT DPDT 8 PIN 8 PIN 24 VAC 120VAC - 2.0 VA 2.0 VA 120 Ω 472 Ω 10,000 Ω 1.2 W 1.2 W 1.2 W DC OPERATED WITH BLOW-OUT MAGNET A314XBX48P69-12D A314XBX48P69-24D A314XBX48P69-110D DPDT DPDT DPDT 8 PIN 8 PIN 8 PIN 12 VDC 24 VDC 110 VDC RELAYS USING MAGNETIC BLOW-OUT MAGNETS ARE NOT AGENCY APPROVED. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 18 SERIES 284 GENERAL PURPOSE 4 POLE 10 AMP PLUG-IN RELAY The series 284 relay is a extension of the Class 388/283 style relay except it provides for 4PDT contacts, any one set of contacts capable of switching 10 Amps (total load of 30 Amps at 120 VAC and 20 Amps at 240 VAC). This relay has the 3 way terminal design for greater flexibility in making connections. The 0.187 Spade terminals can be soldered, plugged into sockets or connected using 3/16" Q.C. Female connectors. UL Recognized File No. E13224 OUTLINE DIMENSIONS Dimensions shown are in INCHES and (millimeters) 0.218 (5.53) 1.50 (38.1) 1.31 (33.3) 1.93 (49.0) MANUAL PUSH BUTTON ACTUATOR (OPTIONAL) 1.87 (47.4) 0.020 Typ. (.508) 0.28 (7.11) 0.187 Typ. (4.74) Struthers-Dunn ORDERING CODE Typical Type No. WIRING DIAGRAM (VIEWED FROM TERMINAL END) 284 XDX C GLM -240A Series 284 3 way terminals 10 Amp, 4 pole Contact Arrangements XDX (4PDT) Construction Style Open, with tapped 6-32 hole - NO CODE Open, with 6-32 Stud - CODE S Enclosed, 3 way terminals - CODE C Options 10 Amp contacts Standard - NO CODE Gold diffused contacts - CODE G Indicator Lamp - CODE L Manual Actuator - CODE M Printed Circuit Terminals - CODE T 5 Amp contacts (Silver) - CODE Y Coil Voltage AC: 6, 12, 24, 48, 120, 240 (Add "A") DC: 6, 12, 24, 48, 115, 125 (Add "D") 1 5 2 6 3 7 9 10 11 13 4 8 12 14 SEE NEXT PAGE FOR RATINGS & SPECIFICATIONS PAGE 19 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 GENERAL PURPOSE 4 POLE 10 AMP PLUG-IN RELAY SERIES 284 UL Recognized File No. E13224 CONTACT RATINGS 120VAC 30VDC LOAD Resistive Motor Load 80% pF. 10A 240VAC 10A 1/3Hp 10A 1/2Hp Maximum total load for 4 pole relay is 30 Amps @ 120VAC, 20Amps @ 240VAC GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: AC: 85%, DC: 75% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 15 mS Max. @ Nominal Voltage. 10 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation Resistance: TEMPERATURE Temperature Rating: 500 V rms across open contacts 1500 V rms between current carrying parts 1000 Megohms.min. @ 500 VDC AC: -45˚C to +50˚C @ Rated Operation. (+65˚C for open style) DC: -45˚C to +70 ˚C +85˚C for open style) LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear polycarbonate 5.0 oz. approx.. COIL SPECIFICATIONS @ 25˚C Nominal Voltage 6 12 24 48 120AC or 115-125DC 240AC* Current (MA) Resistance Resistance Ohms ± 10% Ohms ± 10% AC AC DC DC 3 30 200 560 120 12 100 230 48 480 50 115 1920 25 870 8200 13-15 31 4700 -* 12 -* Power Consumption AC DC 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W NOTE: * For 220-250VDC coils use a 8,200 Ω, 5 Watt resistor in series with 110-125 VDC relays WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 20 CLASS GENERAL SPECIFICATIONS 388 & A283 MANUFACTURED UNDER The Class 388 & 283 general purpose relays are available in a wide choice of AC or DC voltages with Indicator Lamp, Push to test QUALITY SYSTEM button and other options. Plug-in style relays have 3-way pierced ISO 9002 & QS 9000 terminals. While spaced for standard plug-in Socket mounting. The flat terminals (0.187 x 0.020) also accept quick connect receptacles or direct soldering. Recognized Component mark for Canada and the United States. C US * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION UL Recognized File No. E43641 NEW! FLANGE MOUNT PLUG-IN P.C. MOUNT CONTACT RATINGS TABLE TOP FLANGE MOUNT TYPICAL OPERATING CHARACTERISTICS (For DC Voltage types only). POLES 120 VAC 240 VAC 1 POLE 13 AMP 1/3 HP 13 AMP 1/2 HP 2 POLE 13 AMP 1/3 HP 13 AMP 1/3 HP 3 POLE 28 VDC POLES SPDT DPDT 13 AMP MIN. OPERATE mW (SENSITIVITY) 125 250 375 12 AMP 1/2 HP 12 AMP OPERATE TIME (Milliseconds maximum.) 18.0 20.0 24.0 11 AMP 1/2 HP 11 AMP RELEASE TIME (Milliseconds Maximum.) 30.0 28.0 26.0 3PDT WIRING DIAGRAMS Viewed from terminal end 1 4 2 5 3 6 1 4 2 5 7 8 9 7 8 B A SPDT A 3 6 1 4 2 5 3 6 9 7 8 9 B A DPDT B 3PDT * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) SEE SECTION 10 FOR MATING SOCKETS PAGE 21 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS GENERAL SPECIFICATIONS 388 & A283 SPECIFICATIONS CLASS 388 & 283 RELAYS COIL Pull-in voltage: 80% of nominal voltage or less. for DC coils. 85% of nominal voltage or less for AC coils. 10% of nominal voltage or more. ± 10 % Measured at 25˚C 1.2 Watts for DC coils, 2 VA to 2.75 VA for AC coils Class "B" (130˚C per UL std. 1446) Capability of DC coils 3.0 Watts max. Continuous Dropout voltage: Resistance: Coil power Insulation System: Maximum coil dissipation: Duty: CONTACTS Contact material: Contact resistance: 3/16" silver cadmium oxide, gold flashed. 50 Milliohms maximum initial resistance at rated current DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole Contacts to frame: Insulation resistance: 2000 V rms 500 V rms 2000 V rms 2000 V rms 1000 Megohms @ 500 VDC TEMPERATURE Operating: Storage -30˚C to +50˚C (AC), -30˚C to +65˚C (DC) -30˚C to 100˚C LIFE EXPECTANCY Electrical: Mechanical: 100,000 Operations @ rated AC load 5,000,000 Operations @ No load MISCELLANEOUS Operating Position: Insulation material: Enclosure: Terminals: Any Molded plastic Clear Polycarbonate dust cover 3/16" solder/plug-in, Printed Circuit terminals other terminals available: .205 x .032, .250 x .032 on special order. Consult Factory. 3.1 oz.. (88 g approx. with cover). Weight: OPTIONAL 1.41 (35.8) TOP FLANGE COVER IS AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY. 2.53 (64.29) 1.90Max. (48.4) 1.40Max. (35.5) .500 (12.7) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 22 CLASS 388 & A283 SQUARE BASE RELAY, SOLDER/PLUG-IN Recognized Component mark for Canada and the United States. CLASS 388 & 283 RELAY C 13 AMP CONTACT RATING US UL Recognized File No. E43641 OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. * MANUFACTURED UNDER QUALITY SYSTEM COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION ISO 9002 & QS 9000 OUTLINE DIMENSIONS Dimensions shown are in "INCH" and (Millimeter) 1.53 Max. (38.8) .187 x .020 (4.76 x 0.51) QC Terminals Typical 1.90Max. (48.4) 1 4 2 5 3 6 7 8 9 1.40Max. (35.5) A B .28 Typ. (7.1) * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 Struthers-Dunn (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW DUAL MARKED PART NUMBERS Struthers-Dunn CLASS 388CP CLASS A283 CONTACT CONFIGURATION COIL Measured @ 25˚C NOMINAL NOMINAL RESISTANCE POWER NOMINAL INPUT VOLTAGE CROSS REFERENCE TO POTTER & BRUMFIELD IDEC AC OPERATED W388ACPX-3 W388ACPX-4 W388ACPX-5 A283XAXC-24A A283XAXC-120A A283XAXC-240A SPDT SPDT SPDT W388ACPX-8 W388ACPX-9 W388ACPX-10 A283XBXC-24A A283XBXC-120A A283XBXC-240A DPDT DPDT DPDT W388ACPX-13 W388ACPX-14 W388ACPX-15 A283XCXC-24A A283XCXC-120A A283XCXC-240A 3PDT 3PDT 3PDT DC OPERATED W388CPX-2 W388CPX-3 W388CPX-6 W388CPX-7 W388CPX-8 W388CPX-10 W388CPX-11 A283XAXC-12D A283XAXC-24D A283XBXC-12D A283XBXC-24D A283XBXC-110D A283XCXC-12D A283XCXC-24D SPDT SPDT DPDT DPDT DPDT 3PDT 3PDT 24 VAC 120VAC 240 VAC, 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz 24 VAC 120 VAC 240VAC, 60Hz 220 VAC, 50Hz - 2.0VA 2.0VA 2.0VA 2.0VA 2.0VA 2.0VA - 2.75VA 2.75VA 2.75VA - 2.75VA 12 VDC 120 Ω 24 VDC 472 Ω 12 VDC 120 Ω 24 VDC 472 Ω 110VDC 10,000 Ω 12 VDC 120 Ω 24 VDC 472 Ω 1.2W 1.2W 1.2W 1.2W 1.2W 1.2W 1.2W KUP5A15 (or F) - 24 KUP5A15 (or F) - 120 KUP5A15 (or F) - 240 RR1BA-U-AC24V RR1BA-U-AC120V RR1BA-U-AC240V KUP11A15 (or F) - 24 KUP11A15 (or F) - 120 KUP11A15 (or F) - 240 RR2BA-U-AC24V RR2BA-U-AC120V RR2BA-U-AC240V KUP14A15 (or F) - 24 KUP14A15 (or F) - 120 KUP14A15 (or F) - 240 RR3B-U-AC24V RR3B-U-AC120V RR3B-U-AC240V KUP5D15 (or F) - 12 KUP5D15 (or F) - 24 KUP11D15 (or F) - 12 KUP11D15 (or F) - 24 KUP11D15 (or F) - 110 KUP14D15 (or F) - 12 KUP14D15 (or F) - 24 RR1BA-U-DC12V RR1BA-U-DC24V RR2BA-U-DC12V RR2BA-U-DC24V RR2B-U-DC110V RR3B-U-DC12V RR3B-U-DC24V PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE GENERAL SPECIFICATIONS & WIRING DIAGRAMS FOR CLASS 388 & A283 RELAYS. F = GOLD FLASHED SEE SECTION 10 FOR MATING SOCKETS PAGE 23 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS SQUARE BASE FLANGE MOUNT RELAYS Recognized Component mark for Canada and the United States. C * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE US UL Recognized File No. E43641 388 & A283 FLANGE MOUNT RELAY 13 AMP CONTACT RATING .187 Q.C. /SOLDER TERMINALS TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION MANUFACTURED UNDER QUALITY SYSTEM ISO 9002 & QS 9000 2.90Max. (73.8) 2.50 (63.5) .187 x .020 (4.76 x 0.51) QC Terminals Typical 1.53 Max. .625 Typ. (38.8) (15.8) .156 (3.9) .187 (4.76) 1.90Max. (48.4) 1.40Max. (35.5) 1 4 2 5 3 6 7 8 9 A B .28 Typ. (7.1) * RELEVANT IEC CONTACT UTILIZATION CATEGORIES Struthers-Dunn AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW CROSS REFERENCE TO COIL Measured @ 25˚C DUAL MARKED PART NUMBERS NOMINAL NOMINAL CONTACT POTTER & Struthers-Dunn RESIS- NOMINAL IDEC INPUT CONFIGURATION BRUMFIELD TANCE POWER W388CQ A283 VOLTAGE (OHMS) AC OPERATED RR1BA-US-AC120V KUP5A55 (or F) - 120 W388ACQX-4 A283XAXC1-120A SPDT 2.0VA 120 VAC RR1BA-US-AC240V KUP5A55 (or F) - 240 W388ACQX-5 A283XAXC1-240A SPDT 240 VAC, 60Hz 2.0VA 220 VAC, 50 Hz KUP11A55 (or F) - 120 RR2BA-US-AC120V W388ACQX-9 A283XBXC1-120A DPDT 2.0VA 120 VAC KUP11A55 (or F) - 240 RR2BA-US-AC240V W388ACQX-10 A283XBXC1-240A DPDT 240 VAC. 60 Hz 2.0VA 220 VAC, 50 Hz KUP14A55 (or F) - 120 RR3B-US-AC120V W388ACQX-14 A283XCXC1-120A 3PDT 2.75VA 120 VAC KUP14A55 (or F) - 240 RR3B-US-AC240V W388ACQX-15 A283XCXC1-240A 3PDT 240VAC, 60Hz 2.75VA 220 VAC, 50Hz DC OPERATED RR1BA-US-DC12V KUP5D55 (or F) - 12 A283XAXC1-12D W388CQX-2 SPDT 1.2W 12 VDC 120 RR1BA-US-DC24V KUP5D55 (or F) - 24 A283XAXC1-24D W388CQX-3 SPDT 1.2W 24 VDC 472 RR2BA-US-DC12V KUP11D55 (or F) - 12 A283XBXC1-12D W388CQX-6 DPDT 1.2W 12 VDC 120 RR2BA-US-DC24V KUP11D55 (or F) - 24 A283XBXC1-24D W388CQX-7 DPDT 1.2W 24 VDC 472 RR3B-US-DC24V KUP14D55 (or F) - 24 W388CQX-11 A283XCXC1-24D 3PDT 1.2W 24 VDC 472 F = GOLD FLASHED PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE GENERAL SPECIFICATIONS & WIRING DIAGRAMS FOR CLASS 388 & A283 RELAYS. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 24 CLASS 388B & A283 SQUARE BASE RELAYS WITH MAGNETIC BLOWOUT Recognized Component mark for Canada and the United States. CLASS 388B & 388DB SQUARE BASE PLUG-IN STYLE WITH MAGNETIC BLOWOUT FOR DC SWITCHING. RATED 3 & 10 AMPS AT 150 VDC C US * UL Recognized File No. E43641 & E13224 COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown are in "INCHES" and (Millimeters) TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY MANUFACTURED UNDER QUALITY SYSTEM ISO 9002 & QS 9000 1.53 Max. (38.8) .187 x .020 (4.76 x 0.51) QC Terminals Typical 1.90Max. (48.4) 1 4 2 5 3 6 7 8 9 1.40Max. (35.5) B A .28 Typ. (7.1) The Class 388B/388DB style relays have the same load specifications as the 388/283 enclosed plug-in style relays plus the additional load ratings charted on this page. See 388& A283 General specifications. WIRING DIAGRAM Viewed from terminal end 1 4 DC LOAD RATINGS DPDT FIG. "A" RESISTIVE 3 AMPS 150VDC SPDT-N.O. -DM FIG. "B" 10 AMPS 150VDC ALSO AVAILABLE RESISTIVE 3 6 7 9 A B DPST-NO & DPST-NC CONTACT VERSIONS WITH BLOWOUT MAGNETS NOW UL APPROVED @ 5 AMPS, 150 VDC. DPDT FIG. "A" 4 6 A B SPST-NO-DM FIG. "B" * RELEVANT IEC CONTACT UTILIZATION CATEGORIES Struthers-Dunn AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW COIL Measured @ 25˚C DUAL MARKED PART NUMBERS WIRING CONTACT CROSS REFERENCE NOMINAL NOMINAL NOMINAL CONFIGUTO Struthers-Dunn DIAG. INPUT RESISTANCE RATION FIG. W388B A283 (OHMS) POWER P O T T E R / B R U M F I E L D VOLTAGE AC OPERATED WITH BLOWOUT MAGNET (3 AMP CONTACTS) W388ABCPX-5 A283XBX69C-120A "A" DPDT - 2.0VA KUEP-11A15-120 120 472 10,000 1.2W 1.2W 1.2W KUEP-11D15-12 KUEP-11D15-24 KUEP-11D15-110 2.OVA KUEP-3A15-120 1.2W 1.2W 1.2W KUEP-3D15-12 KUEP-3D15-24 KUEP-3D15-110 120 VAC DC OPERATED WITH BLOWOUT MAGNET (3 AMP CONTACTS) W388BCPX-2 W388BCPX-3 W388BCPX-5 A283XBX69C-12D A283XBX69C-24D A283XBX69C-110D "A" "A" "A" DPDT DPDT DPDT 12 VDC 24VDC 110 VDC AC OPERATED WITH BLOWOUT MAGNET (10 AMP CONTACTS) W388ADBCPX-5 A283HXX69C-120A 'B' SPST-NO (DM) 120 VAC - DC OPERATED WITH BLOWOUT MAGNET (10 AMP CONTACTS) W388DBCPX-2 W388DBCPX-3 W388DBCPX-5 A283HXX69C-12D A283HXX69C-24D A283HXX69C-110D 'B' 'B' 'B' SPST-NO (DM) 12 VDC SPST-NO (DM) 24 VDC SPST-NO (DM) 110 VDC 120 472 10,000 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE SECTION 10 FOR MATING SOCKETS PAGE 25 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS GENERAL SPECIFICATIONS 389 The Class 389 relays are high quality general purpose relays, designed to switch larger loads without increasing overall size. One, two and three pole relays are available with a choice of Indicator lamp, Push to test button and various contact combinations. Double make and double break styles are available only with a one pole style but is capable of switching larger loads and are especially well suited for switching motor loads. These relays are available in the 30 Amp contact range. * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE Recognized Component mark for Canada and the United States. C US MANUFACTURED UNDER QUALITY SYSTEM ISO 9002 & QS 9000 UL Recognized File No. E43641 IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION FLANGE MOUNT WIRING DIAGRAMS Viewed from terminal end 1 4 2 5 7 8 3 6 9 B A SPDT 1 4 2 5 7 8 A 3 6 1 4 2 5 9 7 8 B A DPDT 3 6 9 1 3 4 6 4 6 A B A B B SPDT-NC-NO(DB-DM) 3PDT SPST-NO-(DM) CLASS 389 DIELECTRIC WITHSTANDING VOLTAGES (VRMS) 1, 2 & 3 POLE STYLE RELAYS POINTS WHERE VOLTAGE IS APPLIED SPDT DPDT ACROSS OPEN CONTACTS POLE- TO- ADJACENT POLE COIL TO FRAME COIL TO CONTACTS CONTACT TO FRAME CONTACTS TO METAL MOUNTING PLATE ( COVER INSTALLED) COIL TO METAL MOUNTING PLATE (COVER INSTALLED) 1000 1600 2200 1600 1000 2200 1600 2200 1600 1000 1600 1600 1600 1600 2200 2200 1600 2200 2200 2200 CLASS 389D DIELECTRIC WITHSTANDING VOLTAGES VRMS) SPDT-NC-NO (DB-DM), SPST-NO - (DM) POINTS WHERE VOLTAGE IS APPLIED ACROSS OPEN CONTACTS COIL TO FRAME COIL TO CONTACTS CONTACT TO FRAME CONTACTS TO METAL MOUNTING PLATE ( COVER INSTALLED) COIL TO METAL MOUNTING PLATE (COVER INSTALLED) ENCLOSED STYLE 3PDT NEW! 1500 1600 2200 1600 2200 2200 * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 TOP FLANGE MOUNT (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 26 CLASS GENERAL SPECIFICATIONS 389 SPECIFICATIONS CLASS 389 RELAYS COIL Pull-in voltage: 80% of nominal voltage or less. for DC coils. 85% of nominal voltage or less for AC coils. 10% of nominal voltage or more. ± 10 % Measured at 25˚C 1.44 Watts for DC coils, 2VA to 3.5VA for AC coils Capability of DC coils 2.5 Watts max. Continuous Class "B" coil system. (130˚C per UL std. 1446). Dropout voltage: Coil resistance: Nominal power: Maximum coil dissipation: Duty: Insulation System: CONTACTS Contact material: Contact Gap: Contact resistance: 1/4" silver cadmium oxide, gold flashed. .015 min. is standard. 50 Milliohms maximum initial resistance at rated current TIMING Operate time, (excluding bounce): Release time, (excluding bounce): 20 milliseconds max.at nominal voltage. 20 milliseconds max.at nominal voltage. DIELECTRIC STRENGTH Insulation resistance: 1,000 Megohms min. @ 500 VDC TEMPERATURE Operating: Storage: -30˚C to +50˚C (AC), -30˚C to +65˚C (DC) -30˚C to 100˚C LIFE Electrical: Mechanical: 100,000 at rated load. 5 Million Operations no load MISCELLANEOUS Enclosure: Operating Position: Insulation material: Terminals: Clear Polycarbonate dust cover Any Molded plastic 1/4" x .032 Q.C. Terminals suitable for solder or Q.C. connectors, also available with Printed Circuit terminals. (.090 x .032) 3.3 oz.. (94 g approx. with cover). Weight: ALSO AVAILABLE OPTIONAL The 300 series was developed as a 600 Volt relay that would accept 1/4" booted terminals. Its extra spacing permits contact gaps to 2 millimeters when required. This increases dielectric strength across open contacts to 2500 Volts RMS. Consult factory for details or additional information. 1.41 (35.8) TOP FLANGE COVER IS AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY. 2.53 (64.29) 1.90Max. (48.4) 1.40Max. (35.5) .500 (12.7) PAGE 27 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS GENERAL CONTACT RATINGS 389 Recognized Component mark for Canada and the United States. C US UL Recognized File No. E43641 1, 2 & 3 POLE NEMA PILOT DUTY CONTACT RATINGS MAXIMUM CURRENT, AMPERES THERMAL NEMA 120 VOLTS CONTINUOUS CONTACT 50/60Hz TEST CURRENT CODE MAKE BREAK DESIGNATION AMPERES 60 30 30 10 5 5 A600 B300 B600 240 VOLTS 50/60Hz MAKE 6.00 3.00 3.00 30 15 15 BREAK 3.00 1.50 1.50 480 VOLTS 50/60Hz 600 VOLTS 50/60Hz MAKE BREAK MAKE BREAK MAKE BREAK 15 1.50 12 1.20 0.75 0.75 6 0.06 7200 3600 3600 720 360 360 CLASS 389D LOAD RATINGS CLASS 389 LOAD RATINGS ENCLOSED STYLE 1, 2 and 3 POLE NO. OF POLES 1 P O L E 2 P O L E 3 P O L E CURRENT OR HORSEPOWER TYPE OF LOAD LOAD VOLTAGE LOAD VOLTAGE FREQUENCY 13A 20A 25A 5A 1HP 1-1/2HP 1HP 660VA 915VA 960VA 765VA B600 28 15 300 600 120 208/240 480/600 120 208 240 480/600 DC DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60Hz RESISTIVE RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY 13A 20A 25A 5A 1HP 1-1/2HP 1HP 660VA 915VA 960VA 765VA B600 28 15 300 600 120 208/240 480/600 120 208 240 460/600 DC DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60Hz RESISTIVE RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY 28 28 15 150 250 300 120/208/240 240 120 120/240 208 DC DC (NO) DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60Hz 50/60 Hz 50/60 Hz 50/60Hz RESISTIVE RESISTIVE RESISTIVE RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY 13A 15A 20A 20A **15A *10A 1/2HP 1HP 3/4HP 470VA 445VA B300 MAXIMUM VOLT-AMPERES ENCLOSED CURRENT OR NO. OF POLES HORSEPOWER 1 30A 30A 10A 1HP 1-1/2HP 765VA 915VA 960VA A600 P O L E LOAD VOLTAGE STYLE LOAD VOLTAGE FREQUENCY 28 300 600 120 200 thru 600 120 208 240,480,600 DC 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz TYPE OF LOAD RESISTIVE RESISTIVE RESISTIVE MOTOR MOTOR PILOT DUTY PILOT DUTY PILOT DUTY PILOT DUTY CLASS 389 BALLAST LOAD RATINGS NO. OF POLES ENCLOSED STYLE 1 POLE 20 AMPS, 277VAC, 50/60Hz 2 POLE 20 AMPS, 277VAC, 50/60Hz 3 POLE 20 AMPS,150VAC, 50/60Hz 6-2/3 AMPS, 277VAC, 50/60Hz DOUBLE BREAK DOUBLE MAKE (1 FORM "X" & "Z") 1 POLE 25 AMPS, 277VAC, 50/60Hz Not CSA rated with ** are UL Appliance rated. All other ratings not so marked are industrial rated * CSA rating only, not UL WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 28 CLASS SQUARE BASE, 30 AMP POWER RELAY 389 CLASS 389D Recognized Component mark for Canada and the United States. 1/4" Q.C. MALE TAB TERMINALS FOR USE WITH FEMALE QUICK CONNECT TERMINALS OR SUITABLE FOR SOLDERING. C US UL Recognized File No. E43641 * TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. MANUFACTURED UNDER QUALITY SYSTEM ISO 9002 & QS 9000 OUTLINE DIMENSIONS Dimensions shown in Inches and (millimeters). 2.90Max. (73.8) .250 x .032 (6.35 x .891) QC Terminals Typical 2.50 (63.5) 1.53 Max. .625 Typ. (38.8) (15.8) FLANGE COVER .156 (3.9) .187 (4.76) 1.90Max. (48.4) 1.40Max. (35.5) 1 4 2 5 3 6 7 8 9 A B .28 Typ. (7.1) * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) CONTACT CONFIGURATION CONTACT RATING W389ADCX-4 W389ADCX-5 SPST-NO-(DM) SPST-NO-(DM) 30 AMP 30 AMP W389ADZCX-3 SPDT-NO-NC (DM-DB) SPDT-NO-NC (DM-DB) 30 AMP SPST-NO-(DM) SPST-NO-(DM) SPDT-NO-NC (DM-DB) SPDT-NO-NC (DM-DB) PART NUMBERS COIL Measured @ 25˚C CROSS REFERENCE NOMINAL NOMINAL TO NOMINAL INPUT RESISTANCE POTTER & BRUMFIELD POWER VOLTAGE (OHMS) AC OPERATED W389ADZCX-4 120 VAC 240VAC, 60Hz 220 VAC, 50Hz - 2.75VA - 2.75VA 24 VAC - 3.75VA 120VAC - 3.75VA 30 AMP 30 AMP 12 VDC 24 VDC 100 400 1.44W 1.44W 30 AMP 12 VDC 100 1.44W 30 AMP 24VDC 400 1.44W KUMP3A5G-120 KUMP3A5G-240 KUMP6A5G-24 KUMP6A5G-120 30 AMP DC OPERATED W389DCX-2 W389DCX-3 W389DZCX-2 W389DZCX-3 KUMP3D5G-12 KUMP3D5G-24 KUMP6D5G-12 KUMP6D5G-24 EXCEPTION TO CROSS REFERENCE: MAGNECRAFT RELAYS ARE RATED AT 3O AMPS , P&B 15 AMPS PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE CLASS 389 GENERAL SPECIFICATIONS AND WIRING DIAGRAMS. PAGE 29 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS SQUARE BASE, 25 AMP POWER RELAY Recognized Component mark for Canada and the United States. C * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE US 389 CLASS 389 RELAY 1/4" MALE TAB TERMINALS FOR USE WITH FEMALE QUICK CONNECT TERMINALS OR SUITABLE FOR SOLDERING UL Recognized File No. E43641 TOP FLANGE COVER AVAILABLE ON SPECIAL ORDER. CONSULT FACTORY IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OPTIONAL INDICATOR LAMP AND PUSH TO TEST BUTTON AVAILABLE ON SPECIAL ORDER. MANUFACTURED UNDER QUALITY SYSTEM OUTLINE DIMENSIONS ISO 9002 & QS 9000 Dimensions shown are in INCH and (Millimeter) 2.90Max. .250 x .032 (73.8) (6.35 x .891) 2.50 QC Terminals Typical (63.5) 1.53 Max. .625 Typ. (38.8) (15.8) .156 (3.9) .187 (4.76) 1.90Max. (48.4) 1.40Max. (35.5) 1 4 2 5 3 6 7 8 9 A B .28 Typ. (7.1) * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) PART NUMBERS FLANGE COVER CONTACT CONFIGURATION CONTACT RATING COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL INPUT RESISTANCE POWER VOLTAGE (OHMS) CROSS REFERENCE TO POTTER & BRUMFIELD AC OPERATED W389ACX-4 W389ACX-8 W389ACX-9 W389ACX-10 SPDT DPDT DPDT DPDT 25 AMP 25 AMP 25 AMP 25 AMP W389ACX-14 W389ACX-15 3PDT 3PDT 20 AMP 20 AMP 120 VAC 24VAC 120 VAC 240 VAC, 60 Hz 220 VAC, 50 Hz 120 VAC 240 VAC. 60 Hz 220 VAC, 50 Hz KUHP5A51-120 KUHP11A51-120 KUHP11A51-120 KUHP11A51-120 - 2.75VA 2.75VA 2.75VA - 2.75VA 2.75VA - - 2.75VA - 100 400 100 400 100 400 1.44W 1.44W 1.44W 1.44W 1.44W 1.44W KUHP5D51-12 KUHP5D51-24 KUHP11D51-12 KUHP11D51-24 - DC OPERATED W389CX-2 W389CX-3 W389CX-7 W389CX-8 W389CX-12 W389CX-13 SPDT SPDT DPDT DPDT 3PDT 3PDT 25 AMP 25 AMP 25 AMP 25 AMP 20 AMP 20 AMP 12 VDC 24 VDC 12VDC 24VDC 12 VDC 24 VDC PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE CLASS 389 GENERAL SPECIFICATIONS AND WIRING DIAGRAMS. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 30 CLASS 25 AMPS METAL ENCLOSED POWER RELAY 97 CLASS 97 POWER RELAY PLUG-IN OR SIDE STUD MOUNT UL Recognized File No. E43641 OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeter) STUD MOUNT 1.60 (40.6) 1.52 (38.6) PLUG-IN, PLAIN COVER, NO STUD 3 Standoffs on Stud Mount Covers only. (Typical) 0.40 (10.1) 1.52 (38.6) 1.52 (38.6) 8-32 Stud 2.06 Max. (52.3) 1.21 (30.7) .310 (7.8) .250 x .030 Q.C. Terminal (Typical) 1.56 (39.7) 3 .110 x .010 Q.C. Coil Terminal (Typical) 1.56 (39.7) 5 4 6 3 7 1.56 (39.7) 1 7 1.56 (39.7) 2 9 9 8 8 COIL Measured @ 25˚C Nominal Nominal Nominal Input Resistance Power Voltage (Ohms) STUD MOUNTING STYLE W97ACSX-3 120 VAC 8 VA W97ACSX-4 240 VAC, 60 HZ 8 VA 220 VAC, 50 HZ W97CSX-1 12 VDC 50 2.5 W W97CSX-2 24 VDC 200 2.5 W PART NUMBERS PLAIN COVER, PLUG-IN (NO STUD) W97CPX-1 W97CPX-2 2 5 10 10 W97ACPX-2 W97ACPX-3 W97ACPX-4 4 1 24 VAC 120 VAC 240 VAC, 60 HZ 220 VAC, 50 HZ 12 VDC 24 VDC 50 200 6 WIRING SCHEMATIC Viewed from Terminal End 3 4 1 7 8 5 6 2 9 10 8 VA 8 VA 8 VA 2.5 W 2.5 W PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PAGE 31 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 METAL ENCLOSED, 25 AMP - 2 FORM "Z" CONTACTS CLASS 97 SPECIFICATIONS FOR CLASS 97 COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Maximum Power Minimum Power: Duty Resistance AC, 85% of Nominal Voltage or less DC, 75% of Nominal Voltage or less 110% of nominal voltage 3 Watts 1.6 Watts Continuous ±10% CONTACTS Contact Configuration: Contact Material: Contact Resistance: DPDT-NC-NO (DB-DM) Silver Alloy 50 Milliohms max. (Initial) Contact Rating: 25 Amps @ 240 VAC Resistive. 25 Amps @ 277 VAC Resistive. 1 HP @ 120 VAC, 2Hp @ 240 VAC 25 Amps Resistive @ 28 VDC. TIMING Operate Time: Release Time: 35 mS Max. @ Nominal Voltage. 35mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: Pole to Pole: Contact to Frame: Insulation Resistance: 2000 V rms 1500 V rms 2000 V rms 2000 V rms 500 VDC Exceeds 100 Megohms min. TEMPERATURE Operating: -35˚C to +70˚C @ Rated Operation. VIBRATION RESISTANCE Functional: 5g's; 10 to 55 Hz, SHOCK RESISTANCE Functional: 10 g's LIFE EXPECTANCY Mechanical (No Load): Electrical (Rated Load): Max. Cycle Rate: 1 Million Operations 100,000 Operations 1800 per hour MISCELLANEOUS Terminals: Enclosure: Operating Position: Weight: All Terminals on Stud mounted relays are 1/4" x .032 Quick Connect Tabs. Plug-in relays have 1/4" x .032 Quick Connect Tabs and .110 Taper Coil Terminals. Plated Steel Any 259.4 grams SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 32 SERIES 219 300 VOLT GENERAL PURPOSE PLUG-IN RELAY THE SERIES 219 GENERAL PURPOSE INDUSTRIAL PLUG-IN RELAYS FEATURE 12 PIN AND 14 PIN BASES. THE COIL IS ENCAPSULATED FOR PROTECTION. NUCLEAR QUALIFIED VERSIONS ARE AVAILABLE. CONSULT FACTORY. UL Recognized File No. E13224 OPTIONAL MANUAL ACTUATOR 2.625 (66.6) WIRING DIAGRAMS BOTTOM VIEW .250 (6.35) 219XBXP (DPDT ) 6 1 7 12 2.593 (65.5) 3.406 (86.5) 219BBXP (DPDT + 2 N.O.) .435 (11) LOCKING CLIP 2 3 4 5 6 11 10 9 8 7 1 0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions 12 6 1 7 12 1.468 (37.2) 219ABAP (DPDT + 1NO & 1 NC ) MODELS AVAILABLE 12 PIN CONTACTS DPDT + 2 NO 219BBXP DPDT 219XBXP 219ABAP DPDT + 1 NO & 1 NC 14 PIN CONTACTS 219XDXP 219FXXP 219DXBP 4PDT 6P-NO 4P-NO + 2P-NC 6 1 7 12 Make before break and other Contact configurations available limited only by the number of terminal pins.Contact Factory. OPTIONAL MANUAL ACTUATOR 3.062 (77.77) .250 (6.35) 2.593 (65.5) 3.406 (86.5) 219FXXP (6P-NO ) 7 1 8 14 219XDXP (4PDT ) .435 (11) LOCKING CLIP 14 13 1 2 12 11 3 4 10 9 8 5 6 7 0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions PAGE 33 7 1 8 14 1.468 (37.2) 219DXBP (4P-NO + 2P-NC ) 7 1 8 14 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 SERIES 300 VOLT GENERAL PURPOSE PLUG-IN RELAY 219 219 GENERAL SPECIFICATIONS COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage Silver Cadmium Oxide, Gold diffused (Standard) TIMING Operate Time: Release Time: 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation : 1500 V rms 1/4" over surface, 1/8" thru Air TEMPERATURE Rated Operation: -10˚C to +60˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Operating Position: Weight: Clear polycarbonate. Vertical, Contacts Up 8.5 oz. (241 g) approx. COIL SPECIFICATIONS @ 25˚C AC RELAYS 50/60 HZ (COIL DATA @ 60HZ Voltage Nominal Voltage 6 12 24 120 240 CONTACT RATINGS BREAK MAKE CARRY RESISTIVE INDUCTIVE DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC) Resistance Milliamperes Impedance Nominal Resistance Milliamperes Ohms Cold Hot Voltage Ohms Cold Hot Ohms ± 10% ± 10% 1.1 6 15.5 1500 840 385 304 7.2 4.2 12 63.5 189 147 750 410 27 15.5 24 (28)* 250 77 375 200 96 120 540 40 32 375 62 86 75 2700 2100 17 16 32 20 13,400 115/125* 6200 * Note: Stock 24 Vdc and 115 Vac relays have nameplates stamped 24-28 and 115-125 Vdc respectively. These relays operate at 80% of the lower voltages and operate within allowable temperature rises at higher voltages. 250 Vdc - Use 125 Vdc relay and series resistor (6000 Ω, 5 W) not supplied. VOLTS 24 VDC 120 VAC 240 VAC 28 VDC 125 VDC 30A 30A 30A 30A 30A 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 10A 3A 1A 3A 0.1A For versions with suffix "69" Permanent Magnet Blowouts 125 VDC 125 VDC 250 VDC 250 VDC SM DM SM DM 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150 mA 0.5A Struthers-Dunn ORDERING CODE Typical Type No. 219 XBX P L -24D Series 219 Industrial plug-in style Contact Arrangements XBX (DPDT) ABA (DPDT + 1 Pole-NO & 1 Pole NC) BBX (2 Pole-NO & DPDT) XDX (4 PDT) FXX (6 Pole-NO) DXB (4 Pole-NO & 2 Pole-NC) Standard Features Polycarbonate Cover- CODE "P" Optional Features Indicator Lamp - CODE "L" Manual Actuator- CODE "M" 130˚C Coil - CODE "U" Bifurcated Contacts - CODE "33" Perm. Magnet Blowout- CODE "69" Coil Voltage AC: 6, 12, 24, 120, 240 (Add "A") DC: 6, 12, (24-28), 32, 115/125 (Add "D") Coil Voltages & Frequencies must be specified. SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 34 SERIES RSX 1800 INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE The RSX1800 Series Alarm Relay consists of a pair of 2 pole or 3 pole relays enclosed in a clear plastic cover. Wired to a 12 Pin Industrial plug. The relay is wired so that it performs the basic functions of Interfacing between a alarm point and an alarm light and/or an acoustic sounding device. The RSX1800 operates from a normally closed trouble contact, while the RSX1800Z operates from a normally open trouble contact. Either a sustained or momentary alarm condition will energize the relay when signalled by an external trouble contact. The Alarm can be allowed to continue until the trouble has been corrected, at which time it automatically resets. 2.625 (66.6) 2.593 (65.5) 3.406 (86.5) 0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions .435 (11) LOCKING CLIP 12 11 10 9 8 7 1 2 3 4 5 6 1.468 (37.2) COIL DATA Measured at 25˚C AC Coils, 50/60Hz AC Coils, 50/60Hz Ohms mA Volts Volts Ohms mA 6 6 35 170 10.7 200 12 12 150 80 41.1 100 24 24 59 560 43 170 120 10 115-125 11,000 10.5 4500 Struthers-Dunn ORDERING CODE Typical Type No. RSX1800 S 120A Series 219 Industrial plug-in style Alarm relay 5 Amp, 2 Pole Design for Trouble Contacts Operate from N.C. trouble contact- CODE S* Operate from N.O. Trouble contact- CODE Z* Coil Voltage AC: 6, 12, 24, 120, (Add "A") DC: 6, 12, 24 110-125 (Add "D") * Codes "S" & "Z" are 120 VAC only. All other codes are "AD" for NC input or "ZZ" for NO input. SEE SECTION 10 FOR MATING SOCKETS PAGE 35 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 SERIES INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE RSX 1800 GENERAL SPECIFICATIONS CONTACTS Contact Material: Silver Cadmium Oxide. 5 AMP, 120Vac/30Vdc Resistive 20 mS Max. @ Nominal Voltage. Rating: LEGEND TIMING Operate Time: Release Time: K1 - Alarm/Silencing Relay. K2 - Alarm/Silencing Relay. A - Horn & optional Flasher. TT - Lamp test (optional). L1 - Line voltage. R - Reset (optional for manual reset only. S - Horn Silence (acknowledge). F - Flasher (Optional). N - Neutral. Relays are supplied only with the items and wiring shown within the rectangles in schematics. 25 Milliseconds max. 20 milliseconds max. DIELECTRIC STRENGTH Across open contacts: Between all mutually insulated current carrying parts: NOTE: For additional alarms, jumper to like terminals as shown. 500 V rms 1500 V rms TEMPERATURE Rated Operation: -10˚C to +70˚C LIFE EXPECTANCY Mechanical: Electrical: 20 Million Operations no load 500,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Operating Position: Weight: Clear polycarbonate. Any 8.8 oz (250 g) approx. * OMIT for RESET (RSX1800Z) MANUAL RESET (RSX1800S) Manual (Push-button) K1 K2 Flasher Horn Reset Sequence. 1- Normal ON ON OFF OFF 2- Alarm OFF ON ON ON 3- Acknowledge OFF OFF OFF OFF 4- Alarm Contact Recloses OFF OFF OFF OFF 5- Reset ON ON OFF OFF 6- Lamp Test ON ON OFF OFF AUTOMATIC RESET (RSX1800S) Lamp OFF Flashing ON ON OFF ON Automatic Reset Sequence. 1- Normal 2- Alarm 3- Acknowledge 4- Alarm Contact Recloses 5- Lamp Out RSX1800S NC Alarm contact K1 N 1 7 Acknowledge Flasher Contact K2 5 K2 K1 K1 K2 3 L1 6 RS F T K1 OFF ON AUTO or MANUAL RESET K1 1 3 K1 N 6 SF T K1 K1 7 1 8 Horn Acknowledge Alarm Lamp DS Flasher Contact Lamp Test N L1 R Flasher Motor M K2 K2 9 5 K2 K1 K1 K2 3 6 Horn 4 K2 K2 Alarm Lamp DS K1 2 12 A K1 No trouble contact 4 K2 K2 2 Lamp Test L1 Flasher Motor M K2 K2 9 5 K2 K1 K1 K2 Flasher Contact Alarm Lamp DS A Reset 7 Horn N L1 K1 K2 Acknowledge 12 RSX1800Z N 8 NC Alarm cont. 9 K1 2 Lamp Test Flasher Motor M 4 K2 K2 OFF OFF OFF OFF RSX1800S L1 K1 K2 K2 On On ON ON External Jumper 8 Reset ON ON OFF OFF OFF OFF ON ON ON Flashing OFF OFF OFF OFF ON 1- Normal OFF ON OFF OFF OFF 2- Alarm ON ON ON ON Flashing 3- Acknowledge ON OFF OFF OFF ON 4- Trouble Contact Reopens. Auto reset OFF ON OFF OFF OFF Manual reset ON OFF OFF OFF ON 5- Reset OFF ON OFF OFF OFF 6- Lamp Test OFF ON OFF OFF ON * External Jumper supplied be Customer. AUTOMATIC RESET MANUAL RESET L1 K1 K2 Flasher Horn Lamp Automatic or Manual K1 K2 Flasher Horn Lamp K1 SFT WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 12 A N PAGE 36 CLASS FLASH TRANSFER RELAY SWITCHES TUNGSTEN LOADS 21 CLASS 21 MEETS NEMA STD. TS 2- 1992 APPROVED BY D.O.T FOR: California Minnesota Georgia New York Illinois Texas Oregon Colorado Missouri PLUG-IN BASE WITH POLARIZING PIN DPDT CONTACT CONFIGURATION SWITCHES TUNGSTEN LAMP LOADS UP TO 20 AMPS Recognized Component mark for Canada and the United States. C US UL Recognized File No. E43641 OUTLINE DIMENSIONS DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS) 1.85 Max. (46.9) .060 (1.5) .500 (12.7) 2.84 Max. (72.2) Polarizing Pin WIRING DIAGRAM VIEWED FROM PIN END .250 Typ. (6.35) 2.12. (53.9) 2.47 Max. (62.7) .437 Typ. (11.09) 3.90 Max. (99.2) .500 Typ. (12.7) .600 (15.4) 1.00 (25.4) 7 8 5 6 3 4 v1 2 Rectified Coil SPECIFICATIONS CLASS 21 RELAY COIL Pull-in Voltage: AC: 70% of Nominal @ 20˚C or less Dropout Voltage: Coil Insulation : 10% of Nominal Voltage or more Class "B" System (130˚C) per UL 1446 TEMPERATURE Operating: CONTACTS Contact Material: Silver alloy 3/8" dia. Contact Configuration: DPDT Contact Rating: LIFE EXPECTANCY Electrical: 20Amps, 28VDC (Resistive). 1-1/2 HP, 120VAC (Motor) 2HP, 240VAC (Motor) 20Amps, 120VAC (Tungsten Lamp) 10Amps, 240VAC (Tungsten Lamp) Dual Marked Part Number W21ACPX-2 /W21ACPXD-5 DIELECTRIC STRENGTH Across open contacts 500 V rms Contact to Coil: 1500 V rms Contact to Frame: 1500 V rms Mechanical: MISCELLANEOUS Enclosure: Operating Position: Weight: Contact Configuration DPDT -40˚C to +84˚C 200,000 Operations min. at 20 Amps Tungsten, 120VAC. 5 Million Operations MIN. (No Load) Clear Polycarbonate Vertical contacts up or horizontal 7.2 oz.. 204.7 Grams Coil Measured at 25˚C Nominal Voltage Nominal Power 120VAC 4.0 VA Type * Rectified * Rectified type coil provides: 1. Chatter Free operation in Brownout conditions down to 85VAC and will not overheat up to 130VAC. 2. Less Power consumption and less Heating. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PAGE 37 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS 10 AMP, HERMETICALLY SEALED, STEEL CAN RELAY 88HP CLASS 88HP 8 OR 11 PIN OCTAL BASE HERMETICALLY SEALED STEEL CAN Enclosure is filled with dry nitrogen,solder sealed and then electronically leak checked to prevent contamination of Internal parts. The case is painted gray to protect against the elements. CONTACT RATINGS TABLE WIRING DIAGRAM VIEWED FROM PIN END 120 VAC 240 VAC 2 POLE 12 AMP 1/3 HP 8 AMP 1/2 HP 10 AMP 3 POLE 10 AMP 1/3 HP 6 AMP 1.2 HP 10 AMP POLES 28 VDC SPECIFICATIONS CLASS 88HP RELAY DPDT COIL Pull-in voltage: 3PDT Dropout: Coil resistance Nominal power: Max.coil Dissipation: Duty: OUTLINE DIMENSIONS Dimensions are shown in Inch and (Millimeter). 1.53 (38.8) 2.03 (51.5) CONTACTS Contact material: Contact resistance: 3/16" silver cadmium oxide, gold flashed. 50 Milliohms maximum initial resistance at rated current TIMING Operate time: Release time: 25mS or less at nominal voltage. 20mS or less at nominal Voltage. DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole Contacts to frame: Insulation resistance: 1500 V rms 1000 V rms 1500 V rms 1500 V rms 10,000 megohms min. @ 500 VDC TEMPERATURE Operating: Storage: -10˚C to +50˚C (AC), -10˚C to +60˚C (DC) -30˚C to 105˚C SHOCK RESISTANCE Operating: Non operating: 5 G's 20 G's VIBRATION RESISTANCE Operating: Non operating: 5 G's, 10 Hz to 55 Hz 5 G's, 10 Hz to 55 Hz MISCELLANEOUS Enclosure: Terminals Operating Position: Weight:. 1.68 (42.8) CONTACT NO. OF PINS CONFIGUOCTAL PART NUMBERS RATION STYLE AC OPERATED 50/60Hz Operation. 8 PIN W88AHPX-24 DPDT 11 PIN W88AHPX-36 3PDT 80% of nominal voltage or less. For DC coils 85% of nominal voltage or less. For AC coils. 10% of nominal voltage or more. ± 10 % measured @ 25 ˚C 1.5 Watts for DC coils, 3VA for AC coils DC coils 3.0 Watts max. Continuous Hermetically Sealed Steel Can with octal plug. 8 or 11 pin octal plug-in Any 5 ozs. 141.7 g approx. COIL Measured @ 25˚C CROSS REFERENCE NOMINAL NOMINAL TO NOMINAL INPUT RESISTANCE POWER POTTER & BRUMFIELD* VOLTAGE (OHMS) 120VAC 120VAC - 3.0VA 3.0VA KR11AGE (or GF) 120 KR14AGE (or GF) 120 12 VDC 24 VDC 24 VDC 100 400 400 1.5W 1.5W 1.5W KR11DGE (or GF) 12 KR11DGE (or GF) 24 KR14DGE (or GF) 24 DC OPERATED W88HPX-33 W88HPX-34 W88HPX-51 DPDT DPDT 3PDT 8 PIN 8 PIN 11PIN PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION * GF = GOLD FLASHED SPDT and other special contact combinations along with other coil voltages up to 240VAC are available. Consult Factory. SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 38 S E C T I O N 2 2 PRINTED CIRCUIT BOARD RELAYS 1 TO 30 AMPERES Page 39 Magnecraft Struthers-Dunn HI-CURRENT P.C. BOARD RELAYS 276 RELAY SERIES 90 91 Pending FEATURES SUBMINIATURE EPOXY SEALED IMMERSION CLEANABLE EPOXY SEALED IMMERSION CLEANABLE. EPOXY SEALED IMMERSION CLEANABLE. STANDARD 0.1 GRID PATTERN STANDARD 0.1 GRID PATTERN P.C. BOARD OR FLANGE MOUNT STYLES. SINGLE SIDE STABLE DESIGN 5KV SURGE RESISTANCE COIL TO FRAME. CLASS "B" OR "F" INSULATION SYSTEM MEETS UL 508 & UL 873 SPACING SPADE TERMINALS ACCEPT 1/4" Q.C. CONNECT TERMINALS. & 3/16'" COIL Q.C. TERMINALS. MEETS 4mm INTERNATIONAL SPACING COIL TO CONTACT. CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT CONTACT MATERIAL: RESISTANCE: SPST-NO, SPDT (SPST-NO) 10A, 250 VAC/30 VDC (SPDT) 7 A, 250 VAC/30 VDC SILVER ALLOY 100 MILLIOHMS (INITIAL) CLASS "F" INSULATION SYSTEM. SPST-NO SPDT 30A, 240 VAC 20 A 240 VAC (NO) 20A, 30 VDC 15 A,240 VAC (NC) 10A, 30 VDC SPDT SPST-NO 30A, 240 VAC 20 A 240 VAC (NO) 20A, 30 VDC 15 A,240 VAC (NC) 10A, 30 VDC SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (AC) WATTS,: (DC) 2000 V rms 1500 V rms 2500 V rms NOT AVAILABLE 5, 6, 12, & 24VDC NOT AVAILABLE 5, 12, 24 & 110 VDC 24, 120 & 240 VAC NOT AVAILABLE 200 MILLIWATTS MILLIWATTS 930 2 VA - GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: - 40˚ C to + 70˚ C - 55˚ C to + 105˚ C - 55˚ C to + 130˚ C - 55˚ C to + 85˚ C - 55˚ C to + 130˚ C TIMING VALUES OPERATE: RELEASE: 10 MILLISECONDS 10 MILLISECONDS 15 MILLISECONDS 10 MILLISECONDS 20 MILLISECONDS 20 MILLISECONDS LIFE MECHANICAL: ELECTRICAL: 20 MILLION OPERATIONS 100,000 OPERATIONS 10 MILLION OPERATIONS 100,000 OPERATIONS 10 MILLION OPERATIONS 100,000 OPERATIONS DIMENSIONS H W L H .394 X .50 X .787 APPROVALS PAGE NUMBER C PAGE 44 W L .805 X 1.08 X 1.30 H W L 1.10 X 1.08 X 1.27 US PAGE 45, 46 PAGE 47,48 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 40 Magnecraft Struthers-Dunn HI-CURRENT & MICRO MINIATURE P.C. RELAYS 9A RELAY SERIES NEW! FEATURES 92 NEW! EPOXY SEALED IMMERSION CLEANABLE WITH TAPE SEAL. EPOXY SEALED IMMERSION CLEANABLE WITH TAPE SEAL. P.C. BOARD OR FLANGE MOUNT STYLES. PC BOARD OR FLANGE MOUNT STYLES. CLASS "F" INSULATION SYSTEM. CLASS "F" INSULATION SYSTEM. SPADE TERMINALS ACCEPT INSULATED 1/4" Q.C. CONNECT TERMINALS. & 3/16'" COIL Q.C.TERMINALS. 1/4" SPADE TERMINALS ACCEPT 1/4' Q.C. CONNECTORS. 7 MICRO MINIATURE SIZE CONFORMS TO FCC PART 68.302, 1500V SURGE RESISTANCE, FCC 68.304 1000V DIELECTRIC STRENGTH. EXCELLENT R.F. SWITCHING CHARACTERISTICS HIGH SHOCK & VIBRATION RESISTANCE PC BOARD MOUNTING ON 0.1 GRID PATTERN 94V-0 PLASTIC, EPOXY SEALED CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT CONTACT MATERIAL: RESISTANCE: SPST-NO SPDT SPST-NO DPDT 30A, 240 VAC 20A, 30 VDC 20 A 240 VAC 20A, 28 VDC (NO) 15A,240 VAC 10A, 28 VDC (NC) 30A, 277 VAC 20A, 28 VDC 30A, 277 VAC 20A, 28 VDC (NO) 3A, 277 VAC 3A, 28 VDC (NC) SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE 75 MILLIOHMS (INITIAL) 100 MILLIOHMS (INITIAL) SPDT, DPDT 2 A, 24 VDC 1 A, 100 VAC (DPDT) 2A, 120 VAC (SPDT) 50uA, 50mV MIN. GOLD CLAD SILVER PALLADIUM CROSS BAR 50 MILLIOHMS, (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH 2500 V rms 500 V rms 2500 V rms COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (AC) WATTS,: (DC) NOT AVAILABLE 5, 12, 24 48 & 110 VDC 24, 120 & 240 VAC 12, 24 48 & 110 VDC NOT AVAILABLE 5, 12, & 24 VDC 1 WATT 4 VA 1.7 WATTS 330-370 MILLIWATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: - 55˚ C to + 85˚ C - 55˚ C to + 130˚ C DC,- 40˚ C to + 85˚C -AC,- +65˚C - 35˚ C to + 70˚ C TIMING VALUES OPERATE: RELEASE: 15 MILLISECONDS 15 MILLISECONDS 15 MILLISECONDS 10 MILLISECONDS 4.0 MILLISECONDS 5.0 MILLISECONDS LIFE MECHANICAL: ELECTRICAL: 10 MILLION OPERATIONS 100,000 OPERATIONS 5 MILLION OPERATIONS 100,000 OPERATIONS 100 MILLION OPERATIONS 100,000 OPERATIONS DIMENSIONS H W L 1.10 X 1.08 X 1.27 APPROVALS C PAGE NUMBER PAGE 41 US PAGE 49, 50 H W L 1.10 X 1.36 X 1.27 C US PAGE 51, 52 H W L .428 X .410 X .410 C US PAGE 53, 54 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 Magnecraft Struthers-Dunn MINIATURE P.C. BOARD RELAYS 60 49 178 MINIATURE SIZE MINIATURE EPOXY SEALED. DUST COVERED CONFORMS TO FCC PART 68.302, 1500V SURGE RESISTANCE, FCC 68.304 1000V DIELECTRIC STRENGTH. P.C. BOARD MOUNTING. DISPLACES APPROXIMATELY 1.1 CUBIC INCH. EXCELLENT R.F. SWITCHING CHARACTERISTICS SWITCHES UP TO 12 AMP LOADS. CLASS "B" OR "F" INSULATION SYSTEM HIGH SHOCK & VIBRATION RESISTANCE IMMERSION CLEANABLE. PC BOARD MOUNTING ON 0.1 GRID PATTERN. DISPLACES APPROXIMATELY .43 CUBIC INCH. SPDT, DPDT 2 A, 24 VDC 1 A, 100 VAC (DPDT) 2A, 120VAC )SPDT) 50uA, 50mV MIN. GOLD CLAD SILVER PALLADIUM CROSS BAR 50 MILLIOHMS MAX (INITIAL) 330-370 MILLIWATTS TV-5 RATINGS AVAILABLE. SPDT SPDT 5 AMP @ 125/250VAC, 30VDC (CLASS 178RE1-) 12 AMP @ 120VAC, 28VDC 10AMP @ 125/250 VAC, 30 VDC (CLASS 178URE1-) SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL) 500 V rms NOT AVAILABLE 5, 12, & 24 VDC VARIETY OF MOUNTING CONFIGURATIONS. 1500 V rms NOT AVAILABLE 5, 12, & 24 VDC 400 MILLIWATTS 3 AMPS @ 120 VAC/ 28 VDC 5 & 10 AMP @ 240VAC/28VDC SILVER, GOLD PLATED, SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL) 1500 V rms NOT AVAILABLE 3, 5, 6, 12, & 24 VDC 400 MILLIWATTS - 35˚ C to + 70˚ C - 40˚ C to +70˚ C (272) - 55˚ C to + 85˚ C - 55˚ C to + 130˚ C 4.0 5.0 20 MILLISECONDS 10 MILLISECONDS 10 MILLISECONDS 7 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS 50 MILLION OPERATIONS 100,000 OPERATIONS MILLISECONDS MILLISECONDS 100 MILLION OPERATIONS 100,000 OPERATIONS H W L .570 X .895 X 1.10 C US PAGE 55, 56 H W L .620 X .650 X .890 C H W L 1.14 X .759 X 1.25 US PAGE 57, 58 PAGE 59 , 60 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 42 Magnecraft Struthers-Dunn MINIATURE P.C. BOARD RELAYS RELAY SERIES 76 1330 & 1335 NEW! SEE SECTION 10 FOR MATING SOCKETS FEATURES MINIATURE SIZE EPOXY SEALED IMMERSION CLEANABLE. ENCLOSED SEE THRU COVER WITH P.C. TERMINALS. MEETS 8 MILLIMETER SPACING COIL TO CONTACTS AC OR DC OPERATION MEETS 4KV DIELECTRIC WITHSTANDING VOLTAGE. CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT CONTACT MATERIAL: RESISTANCE: INSULATION CHARACTERISTICS DIELECTRIC DPDT SPDT SPDT, DPDT 10 AMPS @ 250 VAC/ 30 VDC 5 AMP RESISTIVE OR 3 AMP INDUCTIVE SWITCHING. UL RATED - 5A, 120VAC, NON UL RATED - 5A, 30 VDC 3A, 120VAC INDUCTIVE. 1/8 HP, 120 VAC 16AMPS @ 240 VAC/ 24 VDC SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL) 100 MILLIOHMS MAX. (INITIAL) STRENGTH 4000 V rms 1500 V rms SPECIAL ORDER 5,6, 12, 24 & 48 VDC 24, 120 VAC 12, 24 VDC COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (AC) WATTS,: (DC) 520 1.2 VA 1.2 W MILLIWATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: - 20˚ C to + 70˚ C - 45˚ C to + 70˚ C TIMING VALUES OPERATE: RELEASE: 15 MILLISECONDS 10 MILLISECONDS 20 20 LIFE MECHANICAL: ELECTRICAL: 20 MILLION OPERATIONS 150,000 OPERATIONS AC, 50 M. DC, 100M OPERATIONS 100,000 OPERATIONS DIMENSIONS PAGE NUMBER PAGE 43 H H W L .811 X .512 X 1.14 APPROVALS W L .905 X .728 X 1.07 C PAGE 61, 62 MILLISECONDS MILLISECONDS US LIMITED RATINGS PAGE 63 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 MINIATURE POWER RELAY 10 AMP, P.C. MOUNTABLE SERIES 276 SERIES 276 ACTUAL SIZE DTL COMPATIBLE SINGLE SIDE STABLE DESIGN 5KV SURGE RESISTANCE COIL TO CONTACT MEETS INTERNATIONAL SPACING -4 mm COIL TO CONTACT SPECIFICATIONS SERIES 276 COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: Nominal Power: 75% of Nominal Voltage or less 10% of nominal voltage or more 110% of nominal voltage. ±10% 200mW Approx. CONTACTS Contact Material: Contact Resistance: Silver Alloy 100 Milliohms initial @ 6VDC, 1 Amp TEMPERATURE Operating:: -40˚C to +70˚C VIBRATION RESISTANCE Functional: 10g's 10 to 55Hz, .06" DA SHOCK RESISTANCE Functional: 100g's no damage LIFE Electrical (Rated Load): Mechanical ( No Load): TIMING Operate Time: Release Time: 10 mS Max. @ Nominal Voltage. 10 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Contacts to Coil: Across open contacts: Surge voltage resistance: Insulation Resistance: 2000 V rms 1000 V rms 5000 V rms between coil and contacts 500 VDC Exceeds 1000 Megohms min.. MISCELLANEOUS Operating Position: Enclosure: Weight: 100,000 Operations 20 Million Operations Any Plastic Cover, Epoxy sealed, 0.2 oz. ( 5.5 grams) approx. LOW LEVEL LOADS: NOT SUITABLE BELOW 20 WATTS OUTLINE DIMENSIONS Dimensions shown are in "Inch" and ( Millimeter) - .787 Max. (20) CIRCUIT BOARD SPACING Layout shown is on a 0.100 Grid BOTTOM VIEW WIRING DIAGRAM BOTTOM VIEW + SPDT .051 Dia. (1.3) 5 Places .394 Max. (10) + - 0.50 (12.7) .138 (3.5) SPST-NO .015 x .030 (.4 x .8) 3 Places 0.20 Dia. (0.5) 2 Coil Terminals Struthers-Dunn CONTACT LOAD RATINGS LOAD CONDITION SPST-NO 10 AMPS @ 250 VAC 10 AMPS @ 30 VDC * MAX. SWITCHING POWER: 300 WATTS (DC) 2500 VA (AC) * MAX. SWITCHING CURRENT: 10 AMPERES * MAX. SWITCHING VOLTAGE: 125 VDC 380 VAC 1/6 HP @ 120 VAC MOTOR: B300 PILOT DUTY: RESISTIVE LOADS: SPDT 7 AMPS @ 250 VAC 7 AMPS @ 30 VDC 210 WATTS (DC) 1750 VA (AC) 7 AMPERES 125 VDC 380 VAC 1/10 HP @ 120 VAC B300 * Voltage current, and power ratings in the table above are independent maximums and no single value is to be exceeded. Part Numbers 276AXXH-5D 276AXXH-6D 276AXXH-12D 276AXXH-24D 276XAXH-5D 276XAXH-6D 276XAXH-12D 276XAXH-24D COIL - Measured at 25˚C Nominal Nominal Nominal ResisContact Input power tance Configuration Voltage (mW) (Ohms) 200 5 VDC 125 SPST-NO 200 6 VDC 180 SPST-NO 200 12 VDC 720 SPST-NO 200 24 VDC 2880 SPST-NO 200 5 VDC 125 SPDT 200 6 VDC 180 SPDT 200 12 VDC 720 SPDT 200 24 VDC 2880 SPDT PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. NOTE: Coil polarity must be observed. Relay is polarized with a permanent magnet and will not be damaged with reverse polarity but will not operate with reverse polarity. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 44 CLASS 30 AMP MINIATURE P.C. BOARD RELAY 90 CLASS 90 RELAY Class 90 printed circuit board relays provide an inexpensive means of switching loads up to 30 amps. Designed primarily for the appliance industry and HVAC markets, they are also well suited for load management, automotive and other applications. SPST-N.O. or SPDT CLASS "B" OR "F" INSULATION EPOXY SEALED. BREAKAWAY NIB OVER VENT HOLE (REMOVED AFTER CLEANING). Recognized Component mark for Canada and the United States. C US UL Recognized File No. E13224 PC BOARD LAYOUT (Bottom View ) Pending A B A B A .100 (2.54) WIRING DIAGRAM .400 (10.1) BOTTOM VIEW .500 (12.7) .600 (15.2) FIG. "A" FIG. "C" SPST-NO SPST-NO NOT USED ON CLASS "F" STYLES .150 (3.8) .550 (13.9) .700 (17.8) .350 (8.9) Drill "A" Holes .086 (2.19). Drill "B" Holes .046 (1.17). FIG."B" FIG."D" SPDT SPDT OUTLINE DIMENSIONS (Actual Size) Dimensions are in Inchs and (Millimeters) VENT HOLE NIB 1.08 MAX. (27.4) .830 MAX. (21.08) .208 Max. (5.28) .100 (2.54) .693 (17.6) 1.30. (33) Stand0ff (qty.5) .78 (19.8) .96 (24.3) PAGE 45 .031 x .062 (.8 x 1.6) .045 x .045 (1.1 x 1.1) .150 (3.8) Pin removed on Class "F" styles. .025 x .025 (.64 x .64) WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS 30 AMP MINIATURE P.C. BOARD RELAY 90 SPECIFICATIONS CLASS 90 COIL Pull-in Voltage: Dropout Voltage: Coil Power: Duty: Insulation System: Coil Resistance: 75% of Nominal Voltage or less 10% of Nominal Voltage or more. 2.8 Watts Max. Continuous Class "B" (130˚C) or Class "F" (155˚C ±10% measured at 25˚C CONTACTS Contact Configuration: Contact Material: Contact Resistance: SPST-N.O., SPDT Silver Cadmium Oxide. 50 Milliohms Max. Initial Value. TIMING Operate Time: Release Time: 15 mS Max. @ Nominal Voltage. 10mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open Contacts Contacts to Coil: Insulation Resistance: Voltage Load Type Resistive Resistive Ind. & Res. AC Motor DC Tungsten Ballast Resistive VIBRATION RESISTANCE Functional: 10 to 55 Hz @ Double Amplitude of 1 mm. SHOCK RESISTANCE Functional: Mechanical: 10 g's for 11 mS, no Contact Opening > 100uS, 100 g's Electrical (Rated Load): Operations: See Table Below Mechanical (No Load): 10 million Operations . MISCELLANEOUS Operating position: Enclosure: Weight: SILVER CADMIUM OXIDE CONTACT RATINGS SPST N.O. 30A @ 240VAC 20A @ 277 VAC 12A @ 277 VAC 1HP @ 125VAC 3/4 HP @ 125VAC 2HP @ 240/250VAC 470VA @ 125/240VAC 30FLA/96LRA, 125VAC 30FLA/80LRA, 240VAC 20FLA/60LRA, 277VAC 27FLA/82.8LRA,125VAC TV 3 @ 250VAC 6Amp @ 277VAC 20A @ 5-30VDC -55˚C to +105˚C -55˚C to +130˚C Up to 93% @ 40˚C. 650 to 800 mmHg. LIFE 1000 V rms 1500 V rms 500 Megohms under normal conditions 100 Megohms High Temp, High humidity. R TEMPERATURE Operating: Storage: Relative Humidity: Atmospheric Pressure: FIGURE "C" & "D" MEETS UL 508 & UL 873 SPACING . SPDT N.O. OPERATIONS 20A @ 240VAC 100,000 20A @ 277 VAC 100,000 12A @ 277 VAC 6,000 30,000 1HP @ 125VAC 100,000 3/4HP @ 125VAC 1,000 2HP @ 240/250VAC 470VA @ 125/240VAC 100,000 30,000 30FLA/96LRA, 125VAC 30,000 30FLA/80LRA, 240VAC 20FLA/60LRA, 277VAC 100,000 27FLA/82.8LRA,125VAC 100,000 25,000 TV 3 @ 250VAC 6Amp @ 277VAC 6,000 20A @ 5-30VDC 100,000 COIL Measured @ 25˚C PART NUMBERS NOMINAL NOMINAL INPUT RESISTANCE VOLTAGE (Ohms) Any 94V-0 Flammability rating, Epoxy sealed Immersion cleanable. 27 Grams approximately. NOMINAL POWER (mW) SPDT N.C. OPERATIONS 100,000 2-10A @ 240VAC, (i&R) 15 AMP @ 240 (i) 100,000 6A @ 277VAC, I&R 6,000 1/4HP @ 125VAC 1/2HP @ 250VAC 275VA @ 125/240VAC 10FLA/33LRA, 125VAC 10FLA/33LRA,240VAC TV 3 @ 250VAC 3 AMP@ 277VAC 10A @ 5-30VDC 30,000 30,000 30,000 100,000 100,000 6,000 100,000 CROSS REFERENCE POTTER & BRUMFIELD OMRON SPST-NO , ( 30 AMP ) CLASS "B" INSULATION, FIG "A" WIRING W90S1D12-5 W90S1D12-12 W90S1D12-24 W90S1D12-110 5VDC 12VDC 24VDC 110VDC 27 155 660 13,450 930 930 870 900 T90S1D12-5 T90S1D12-12 T90S1D12-24 T90S1D12-110 G8P1114PB1USDC5 G8P1114PB1USDC12 G8P1114PB1USDC24 G8P1114PB1USDC110 930 930 870 900 T90S5D12-5 T90S5D12-12 T90S5D12-24 T90S5D12-110 G8P114PB1USDC5 G8P114PB1USDC12 G8P114PB1USDC24 G8P114PB1USDC110 930 930 870 900 T90S1D42-5 T90S1D42-12 T90S1D42-24 T90S1D42-110 G8P1114PCFUSDC5 G8P1114PCFUSDC12 G8P1114PCFUSDC24 G8P1114PCFUSDC110 930 930 870 900 T90S5D42-5 T90S5D42-12 T90S5D42-24 T90S5D42-110 G8P114PCFUSDC5 G8P114PCFUSDC12 G8P114PCFUSDC24 G8P114PCFUSDC110 SPDT, ( 20 AMP ) CLASS "B" INSULATION, FIG "B" WIRING W90S5D12-5 W90S5D12-12 W90S5D12-24 W90S5D12-110 5VDC 12VDC 24VDC 110VDC 27 155 660 13,450 SPST-NO, ( 30 AMP ) CLASS "F" INSULATION, FIG "C" WIRING W90S1D42-5 W90S1D42-12 W90S1D42-24 W90S1D42-110 5 VDC 12 VDC 24 VDC 110VDC 27 155 660 13,450 SPDT, ( 20 AMP ) CLASS "F" INSULATION, FIG "D" WIRING W90S5D42-5 W90S5D42-12 W90S5D42-24 W90S5D42-110 5 VDC 12 VDC 24 VDC 110VDC 27 155 660 13,450 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 46 CLASS 30 AMP PC or FLANGE MOUNT MINIATURE RELAY 91 CLASS 91 RELAY AC COIL VOLTAGES 30 AMP SWITCHING CLASS "F" INSULATION PC or FLANGE MOUNTED. * REMOVABLE TAPE SEAL OVER VENT HOLE (REMOVED AFTER PC BOARD DRILL PATTERN CLEANING). BOTTOM VIEWS .250 Max. (6.35) .300 (7.62) .250 Max. (6.35) .100 (2.54) A A A .500 (12.7) B .150 (3.81) HOLE "A" = .081 (005) Dia. HOLE "B" = .043 (003) Dia. B .550 (13.9) .700 (17.8) *Tape over vent hole is only supplied on the P.C. terminal versions of this relay. OUTLINE DIMENSIONS (Actual Size) Dimensions are in "inches" & (Millimeters) .032 x .62 (.81 x 1.57) N.C. A1 FIGURE "A" P.C. MOUNT N.O. A1 1.270 Max. (32.26) A1 COM. 1.10 Max. (27.94) 1.080 Max. (27.43) .045 x .046 (1.14 x 1.14) .025 x .025 (.63 x .63) 2 places .130 ± .020 (3.30 ± .51) WIRING DIAGRAM BOTTOM VIEWS N.C. A1 N.O. A1 1.713 ± .010 (43.51 ± .25) A1 COM. B1 1.980 Max. (50.29) 1.27 Max. (32.26) FIGURE "B" FLANGE MOUNT SPDT SPST-NO B1 .071Rad. (1.80) For #6 screw ( 2 places) A1 = .250 x .032 (6.35 x .81) Quick Connect Terminal B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal PAGE 47 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 30 AMP PC or FLANGE MOUNT MINIATURE RELAY CLASS 91 SPECIFICATIONS CLASS 91 COIL Pull-in Voltage AC: Dropout voltage: Max. coil voltage: Power consumption: Duty: Insulation System: Coil Resistance TEMPERATURE Operating: Storage: 85% of Nominal Voltage or Less 10% of Nominal voltage or More 120% Max. 2.0VA max. AC Coils Continuous Class "F" (155˚C) ±10% measured @ 25˚C -55˚C to +85˚C -55˚C to +130˚C VIBRATION RESISTANCE Functional: 10 to 55Hz 1.5 mm max. No contact opening 100 > uS SHOCK RESISTANCE Functional: CONTACT Contact Configuration: Contact Material: Switching voltage: Contact Resistance: Minimum Load: SPST-N.O., SPDT Silver Cadmium Oxide 277 Vac, 30VDC max. 50 Milliohms @ 100mA, 6VDC Max. 1A, 5VDC, 12VAC TIMING Operate Time: Release Time: 20 mS max 20 mS max. DIELECTRIC STRENGTH Between Open Contacts: Contacts to coil: Insulation Resistance 1500 V rms 2500V rms 1000 mΩ min. @ 500 VDC 10 g's for 11 mS, No contact Opening > 100 uS 100 g's Mechanical: LIFE Electrical (Rated Load) Mechanical (No Load): 100,000 Operations 1 million Operations (AC) 10 million Operations (DC) MISCELLANEOUS Operating Position: Enclosure: Any Epoxy sealed immersion cleanable suitable for automatic circuit board processing. Max. exposure to temperature is 6 sec.@ 300˚C. 1/4" Q.C. Contacts, 3/16" Q.C. Coil 33 Grams, 1.2 oz approx. Terminals: Weight: CONTACT RATINGS RATING RESISTIVE 30A @ 240VAC 20A @ 28VDC LOAD 1 HP @120VAC hp 2HP @ 240VAC Tungsten TV-5, 120VAC 10A, 277VAC Ballast LRA/FLA SPDT 50/60Hz SPST-NO 50/60Hz N.O. 80/30 @ 240AC 98/22 @ 120AC N.O. N.C. 20A @ 240VAC 20A @ 28 VDC 1 HP @ 125VAC 2HP @ 240VAC TV-5, 120VAC 10A, 277VAC 50/20 @ 240AC 10A @ 240VAC 10A @ 28VDC 1/4HP @ 120VAC 1/2HP @ 240VAC TV-3, 120VAC 3A, 277VAC 20/7 @ 240AC Coil measured @ 25˚ C PART NUMBERS SPST-NO 30AMP P.C. MT. FIGURE "A" SPDT 20AMP P.C. MT. FIGURE "A" SPST-NO 30AMPFLANGE MT. FIGURE "B" SPDT 20AMP FLANGE MT. FIGURE "B" NOMINAL NOMINAL NOMINAL RESIS- POWER INPUT TANCE (VA) VOLTAGE (Ohms) AC OPERATED COIL W91S1A22-24 W91S5A22-24 W91S1A32-24 W91S5A32-24 24 VAC W91S1A22-120 W91S5A22-120 W91S1A32-120 W91S5A32-120 120 VAC W91S1A22-240 W91S5A22-240 W91S1A32-240 W91S5A32-240 240 VAC - 2 VA 2 VA 2 VA PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 48 CLASS 30 AMP PC or FLANGE MOUNT MINIATURE RELAY 9A CLASS 9A RELAY Recognized Component mark for Canada and the United States. 30 AMP SWITCHING. C US UL Recognized CLASS "F" INSULATION. File No. E43641 PC or FLANGE MOUNTED. EPOXY SEALED WITH REMOVABLE TAPE SEAL OVER VENT HOLE (REMOVED AFTER CLEANING). PC BOARD DRILL PATTERN ! W NE BOTTOM VIEWS .140 Max. (3.56) .300 (7.62) .250 Max. (6.35) .100 (2.54) A A A .600 .500 (15.24) (12.7) .150 (3.81) OUTLINE DIMENSIONS (Actual Size) NC NO .550 (13.97) .700 (17.8) .032 x .62 (.81 x 1.57) A1 A1 FIGURE "A" P.C. MOUNT COM 1.270 Max. (32.26) B HOLE "A" = .081 ± .005 Dia. (2.06 x .13) HOLE "B" = .043 ± .08 Dia. (1.09 x .08) Dimensions are in "inches" & (Millimeters) A1 B 1.10 Max. (27.94) 1.080 Max. (27.43) .045 x .045 (1.14 x 1.14) .025 x .025 (.63 x .63) 2 places .130 ± .020 (3.30 ± .51) WIRING DIAGRAM NC BOTTOM VIEWS COM NO A1 1.713 ± .010 (43.51 ± .25) B1 B1 B1 B1 A1 A1 1.980 Max. (50.29) 1.27 Max. (32.26) FIGURE "B" FLANGE MOUNT SPDT SPST-NO .071Rad. (1.80) For #6 screw ( 2 places) A1 = .250 X .032 (6.35 X .81) Quick Connect Terminal B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal PAGE 49 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 30 AMP PC or FLANGE MOUNT MINIATURE RELAY CLASS 9A SPECIFICATIONS CLASS 9A COIL Pull-in Voltage: Dropout voltage: Max. coil voltage: Power consumption: Duty: Insulation System: Coil Resistance CONTACT Contact Configuration: Contact Material: Switching voltage: Contact Resistance: TEMPERATURE Operating: Storage: 75% of Nominal Voltage or Less 10% of Nominal voltage or More 120% Max. 2.8 Watts max. Continuous Class "F" (155˚C) ±10% Measured @ 25˚C -55˚C to +85˚C -55˚C to +130˚C VIBRATION RESISTANCE Functional: SHOCK RESISTANCE Functional: 10 g's for 11 mS, No contact Opening > 100 µS 100 g's SPST-N.O., SPDT Silver Cadmium Oxide 277 VAC, 28VDC max. 75 Milliohms @ 1 min, rated current (switched) 1A, 5VDC, 12VAC LIFE Electrical (Rated Load) Mechanical (No Load): TIMING Operate Time: Release Time: DC:15 mS typ. including bounce DC:15mS typ. including bounce MISCELLANEOUS Operating Position: Enclosure: DIELECTRIC STRENGTH Between Open Contacts: Contacts to coil: Insulation Resistance 1500 V rms 2500V rms 1000 mΩ min. @ 500 VDC, 25˚C 50% RH Minimum Load: 10 to 55Hz 1.65 mm max. No contact opening 100 > uS Mechanical: 100,000 Operations 10 million Operations Typical Any Epoxy sealed immersion cleanable suitable for automatic circuit board processing. Max. exposure soldering temperature is 4 sec.@ 500˚F. 94V-O Flammability rating. 1/4" Q.C. & safety wells accept insulated Female Q.C. terminals. 33 Grams, 1.2 oz approx. Enclosure: Terminals: Weight: CONTACT RATINGS Meets UL 508, UL 873 and UL 1950 - 1/8" thru air - 1/4" over surface (See Foot notes) AC Measured @ 50/60Hz RATING GENERAL PURPOSE RESISTIVE RESISTIVE HEATER †† MOTOR (HP) MOTOR FLA/LRA ‡ TUNGSTEN BALLAST PILOT DUTY LOAD VOLTAGE 240 VAC 240 VAC 28 VDC 240 VAC 125 VAC 240 VAC 120 VAC 240 VAC 240 VAC 277 VAC 240 VAC SPDT SPST OPERATIONS N.O. N.C. N.O. N.C. 30A 20A 20A 25A 1 HP 2 HP 22/98A 30/80A TV-5 10A 470 VA *15A †15A 10A 1/4 HP 1/2 HP 12/30A 3A 275 VA 20A 20A 20A 1 HP 2 HP 30/80A TV-5 10A 470 VA 10A †15A 10A 1/4 HP 1/2 HP 12/30A 3A 275 VA 100,000 100,000 100,000 100,000 1,000 1,000 30,000 30,000 25,000 6,000 6,000 * 15 Amp general purpose rating on SPST-NC contact valid only under UL 508 column B spacings and UL 873 columns B, C & D spacings. Derate to 10 Amps when used under UL 873 columns E & F spacings and UL 1950. † 15 Amp resistive rating on SPST-NC contacts and SPDT contacts (Normally closed side only) valid only under UL 873 columns E & F spacings. Derate to 10 Amps when used under UL 508 Column B spacings, under UL 873 columns B, C & D spacings and UL 1950. †† The resistance heater rating is not a discreet UL heater rating but is a valid UL rating that is derived from the UL general purpose category in the above table of contact ratings. ‡ FLA = Full load Amps, LRA = Locked rotor Amps. Coil measured @ 25˚ C PART NUMBERS SPST-NO 30AMP P.C. MT. FIGURE "A" SPDT 30AMP P.C. MT. FIGURE "A" DC OPERATED COIL W9AS1D22-5 W9AS5D22-5 W9ASID22-12 W9AS5D22-12 W9ASID22-24 W9AS5D22-24 W9ASID22-48 W9AS5D22-48 W9ASID22-110 W9AS5D22-110 SPDT SPST-NO 30AMP 30AMPFLANGE MT. FLANGE MT. FIGURE "B" FIGURE "B" W9AS1D52-5 W9ASID52-12 W9ASID52-24 W9ASID52-48 W9ASID52-110 W9AS5D52-5 W9AS5D52-12 W9AS5D52-24 W9AS5D52-48 W9AS5D52-110 NOMINAL NOMINAL NOMINAL RESIS- POWER INPUT TANCE (Watts) VOLTAGE (Ohms) 5 12 24 48 110 25 144 576 2,304 12,100 1W 1W 1W 1W 1W PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 50 CLASS 92 30 AMP PC or FLANGE MOUNT 2 POLE RELAY Recognized Component mark for Canada and the United States. CLASS 92 RELAY ! W NE 30 AMP SWITCHING. CLASS "F" INSULATION. PC or FLANGE MOUNTED. EPOXY SEALED WITH * REMOVABLE TAPE SEAL OVER VENT HOLE (REMOVED AFTER CLEANING). C US UL Recognized File No. E43641 PC BOARD DRILL PATTERN .162 (4.12) BOTTOM VIEWS .630 ± .005 (16.00) .203 TYP (5.16) .309 ± .005 (7.85 ± .13) .585 ± .005 (14.8 ± .13) HOLE "B" OUTLINE DIMENSIONS HOLE "A" .185 TYP (4.70) Dimensions are in "inches" & (Millimeters) 1.33 Max. (33.78) 1.618 TYP (41.10 ± .51) 1.00 ± .010 (25.40) .309 ± .005 (7.85 ± .13) 2.06 Max. (52.32) .586 ± .005 (14.8 ± .13) FIGURE "A" P.C. MOUNT .047 TYP. (1.19) .250 TYP (6.35) 1.618 TYP (41.10 ± .51) .156 (3.96) .032 TYP (0.81) .630 ± .005 (16.00) HOLE "A" = .072 x .050 typ. (1.83) HOLE "B" = .052 x .050 typ. (1.32) 1.10 Max. (27.94) 1.00 ± .010 (25.40) 1.04 Max. (26.42) Note: An alternate P.C. Board layout Utilizes .076 ±.003 diameter holes on the layout above. Use of retangular holes is recommended for improved solderability. *Tape over vent hole is only supplied on the P.C. terminal versions of this relay. WIRING DIAGRAM TOP VIEW 6 8 7 .309 ± .005 (7.85 ± .13) 2.06 Max. (52.32) 2.35 ±.005 (59.7 ±.13) 0 1 .585 ± .005 (14.8 ± .13) 2.70 Max. (68.58) FIGURE "B" FLANGE MOUNT 1.36 Max. (34.54) .090 Rad (2.29) For #8 screws DPDT 6 8 .250 TYP (6.35) 1.618 TYP (41.10 ± .51) PAGE 51 2 4 3 2 4 0 1 DPST-NO 1.485 Max. (37.72) Only necessary terminals are present on single throw styles. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS 30 AMP PC or FLANGE MOUNT 2 POLE RELAY 92 SPECIFICATIONS CLASS 92 COIL Pull-in Voltage: AC: 80% of Nominal Voltage or Less DC: 75% of Nominal Voltage or Less 10% of Nominal voltage or More Dropout voltage: 120% Max. Max. coil voltage: Max. Operating Frequency: 14 Operations per minute AC Coil: 4.0VA, DC Coil: 1.7W Nominal Power: Continuous Duty: Class "F" (155˚C) Insulation System: ±10% Measured @ 25˚C Coil Resistance CONTACT Contact Configuration: Contact Material: Contact Load Ratings: Contact Resistance: Minimum Load: DPDT Standard Silver Cadmium Oxide SEE CONTACT LOAD RATINGS CHART 100 Milliohms @ Initial rated current (switched) N.O. 500 mA @ 12 VAC/VDC N.C. 100mA @ 6 VAC/VDC TIMING Operate Time: Release Time: DC:15 mS typ. 25ms w/ bounce DC:10mS typ. 25 ms w/ bounce DIELECTRIC STRENGTH Between Open Contacts: Contacts to coil: Insulation Resistance 1500 V rms 4000V rms 103 meg Ω min. @ 500 VDC, 25˚C 50% RH TEMPERATURE Operating: AC:-40˚C to +65˚C, DC:-40˚C to +85˚C VIBRATION RESISTANCE 0.065 (1.65 mm) double amplitude-10 thru 55 Hz Functional: SHOCK RESISTANCE Functional: 10 g's for 11 mS, 1/2 sign wave pulse with no contact opening > 100µs 100 g for 11 ms 1/2 sine wave pulse Mechanical: LIFE Electrical (Rated Load) Mechanical (No Load): 100,000 Operations 5 million Operations Typical MISCELLANEOUS Operating Position: Enclosure: Flammability: Weight: Any Epoxy sealed immersion cleanable tape sealed plastic cover. 94V-O Flammability rating. 86 Grams, 3 oz approx. CONTACT RATINGS Meets UL 873 and UL 508 spacing - (8mm) thru air, (9.5 mm) over surface. AC Measured @ 50/60Hz DPST-N.O. & DPDT RATING N.O. CONTACTS Resistive Load N.C. CONTACTS 30A @ 120/277 VAC 20A @ 28 VDC 1 HP @ 120VAC Hp 2.5 HP @ 240VAC Tungsten TV-10, 120VAC LRA/FLA* 96/22 @ 240VAC, AC Coil 110/25.3 @ 240VAC, DC Coil Pilot Duty DPDT 3A @ 277VAC 3A @ 28VDC 3A @ 240 VAC Note: Vent tape must be removed to achieve listed ratings * FLA = Full load Amps, LRA = Locked rotor Amps. . DPST-NO 30AMP P.C. MT. FIGURE "A" DPDT 30AMP P.C. MT. FIGURE "A" DPST-NO 30AMPFLANGE MT. FIGURE "B" CROSS REFERENCE TO OMRON The relay listed below are crossed to Magnecraft DPST-NO, 30 Amp, Flange mount, Figure "B" only. NOMINAL NOMINAL NOMINAL See Note below for Variations RESISPOWER between relays. INPUT VOLTAGE TANCE (Ohms) OMRON PART NUMBERS Coil measured @ 25˚ C PART NUMBERS DPDT 30AMP FLANGE MT. FIGURE "B" AC OPERATED COIL W92S7A22-24 W92S11A22-24 24 VAC W92S7A22-120 W92S11A22-120 120 VAC W92S7A22-240 W92S11A22-240 240 VAC DC OPERATED COIL W92S7D12-12 W92S11D12-12 W92S7D22-12 W92S11D22-12 W92S7D12-24 W92S11D12-24 W92S7D22-24 W92S11D22-24 W92S7D12-48 W92S11D12-48 W92S7D12-110 W92S11D12-110 W92S7D22-110 W92S11D22-110 12 VDC 24 VDC 48 VDC 110 VDC - 4 VA 4 VA 4 VA G7L-2A-TUBJ-CB-AC24 G7L-2A-TUBJ-CB-AC120 G7L-2A-TUBJ-CB-AC240 86 350 1,390 7,255 1.7 W 1.7 W 1.7 W 1.7 W G7L-2A-TUBJ-CB-DC12 G7L-2A-TUBJ-CB-DC24 G7L-2A-TUBJ-CB-DC110 G7L REPLACES G5D22423T PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. Note: The Class W92 Meets Fit and Function when replacing the Omron G7L relay. The case size ( width & lenght ) and mounting centers on flange are Dimensionally identical except the class 92 is lower in height. The W92 has a higher contact switching rating then the G7L and requires less coil power for operation. The 1/4" (.250) Q.C. terminals on top of the case of the Class 92 are not located in the same positions as the G7L, but wire hookup will work with existing wiring using Q.C. connectors.. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 52 CLASS SUBMINIATURE PC MOUNTABLE, EPOXY SEALED 7 CLASS 7 2 AMP SWITCHING IN THE WORLDS SMALLEST PACKAGE. SPDT, DPDT. ACTUAL SIZE AVAILABLE WITH SPDT OR DPDT BIFURCATED GOLD CLAD SILVER-PALLADIUM CROSS BAR CONTACTS- RATED FOR LOW LEVEL TO 2.0 AMP SWITCHING. REQUIRES ONLY .155 SQUARE INCH OF CIRCUIT BOARD SPACE. TOTAL VOLUME OF LESS THAN A CUBIC CENTIMETER. CONFORMS TO FCC PART 68.302. 1500 V PEAK SURGE RESISTANCE. CONFORMS TO FCC PART 68.304. 1000 V DIELECTRIC WITHSTANDING VOLTAGE.. PC BOARD PATTERN Drill Plan (TOP VIEW) The Class 7 Subminiature high reliability industrial grade relay has excellent R.F. switching characteristics. Recognized Component mark for Canada and the United States. C US UL Recognized File No. E52197 TOP VIEW SHOWN AT ACTUAL SIZE ON A 0.1 GRID DIP CLASS 7 CLASS CLASS 7 7 SIZE COMPARISON OF STANDARD DIP RELAY TO CLASS 7 RELAYS The Class 7 relays can be densely packed together without magnetic interaction from adjacent relays. .100 (2.54) .300 (7.62) .100 (2.54) .100 (2.54) .300 (7.62) .039 Dia. (1.0) 0.1 Grid Pattern OUTLINE DIMENSIONS Dimensions are in "INCHES" and ( MILLIMETERS ) .410 Max. PIERCE THRU (10.4) VENT HOLE WIRING DIAGRAM BOTTOM VIEW v ^ .410 Max. (10.4) SPDT .428 Max. (10.9) v ^ v ^ .100 Typ (2.54) PAGE 53 .125 (3.18) .024 x .012 (0.6 x 0.3 ) DPDT WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 SUBMINIATURE PC MOUNTABLE, EPOXY SEALED COIL Coil Voltages Pull-in Voltage: Dropout: Max. allowed coil voltage: Nominal Power: Max. coil dissipation Coil Resistance range: CONTACTS Contact Configuration: Contact Rating: Contact Material: Contact Resistance: TIMING Operate Time: Release Time: TEMPERATURE Operating: 80% of Nominal Voltage or less 10 % of Nominal Voltage or More 120% of nominal voltage, duty cycle: 100%. 327 Milliwatts max., min sensitivity: 200 milliwatts. 0.75 watts. ±10% SPDT, DPDT SPDT: 50uA @ 50mV, 2A , 24VDC, 2A, 120VAC, DPDT: 50uA @ 50mV, 2A, 24VDC, 0.6A,100VAC, Gold Clad Silver Palladium. Initial 50 mΩ 100 Milliohms max @ 6VDC 10 Milliamps. 4.0 mS Max. @ Nominal Voltage. Typ. 5.0 mS Max. @ Nominal Voltage. Typ -35˚C to +70˚C VIBRATION RESISTANCE Functional: 15 g's, 10 to 2000 Hz, No contact opening > 10 uS Max. contact chatter Destructive: 50 g'S. SHOCK RESISTANCE Functional 50g's 6mS half sine Mechanical: Destructive: 150 g's. LIFE Mechanical: Electrical: 100 Million Operations 100,000 Operations- 2 Amp 24VDC, 1.0 AMP 120VAC (Rated Load). MISCELLANEOUS Terminal Finish: Mounting Position: Enclosure: Weight: Terminals are solder Coated and Epoxy free to provide excellent solderability. Max. exposure to soldering temperature is 5 seconds @ 250˚C. After cleaning process, pierce a small hole in cover for venting. Any UL, 94V-O Plastic, Epoxy Sealed. 2.7 Grams . (.095 oz.) OPERATE/RELEASE TIME 4 After cleaning process, pierce 0.40 (1mm) hole in cover for venting. OPERATE TIME 3 2 COIL TEMPERATURE RISE 80˚ 70˚ 1 TEMP. RISE ˚C MILLISECONDS 7 SPECIFICATIONS CLASS 7 DIELECTRIC STRENGTH All Mutually Insulated Points: 500 VAC for 1 Minute, 1 Milliamp max. leakage, or 600VAC for 1 Second, 1 Milliamp leakage. Meets FCC 68.302 ( 1500V Surge ) Surge Test: and 68.304 ( 1000V Dielectric ). 500 VDC Exceeds 1000 Megohms. Insulation Resistance: RELEASE TIME 0 CLASS 0.7 0.5 0.3 0.6 0.8 0.4 COIL APPLIED POWER (WATTS) 0.9 R.F. PERFORMANCE Frequency (MHz) 10 50 100 200 300 400 500 Insertion Loss (dB) VSWR Isolation (dB) Common to N.O. or N.C. Contacts Common to N.O. or N.C. Contacts N.O. or N.C. Contacts to Coil 0.05 0.10 0.30 0.50 0.60 0.65 0.75 1.03:1 1.04:1 1.05:1 1.06:1 1.07:1 1.08:1 1.10:1 65 50 42 35 31 29 28 Contact Configuration W7PCX-1 W7PCX-3 W7PCX-4 SPDT SPDT SPDT W7PCX-5 W7PCX-7 W7PCX-8 DPDT DPDT DPDT 50˚ E2 R20 40˚ 30˚ 20˚ 10˚ 0 0.1 0.2 0.3 0.4 0.5 0.6 0 . 7 0.8 COIL POWER CONSUMPTION E2 = Rt E2 = R20 COIL - Measured at 25˚C Part Numbers E2 Rt 60˚ COIL VOLTAGE COIL RESIST. VALUE AFTER TEMP. WAS RAISED COIL VOLTAGE COIL RESIST. VALUE AT 20˚C CROSS REFERENCE Nominal Resistance (Ohms) Nominal Power (mW) COMMUNICATIONS INSTRUMENTS INC / MIDTEX (CII / MIDTEX) 5 VDC 12 VDC 24 VDC 75 440 1550 330 330 370 MMS105 MMS112 MMS124 5 VDC 12 VDC 24 VDC 75 440 1550 330 330 370 MMS205 MMS212 MMS224 Nominal Input Voltage PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 54 CLASS 60 MINIATURE P.C. BOARD RELAY MOUNTABLE ON 0.100 GRID CLASS 60 BIFURCATED CROSS BAR CONTACTS LOW LEVEL SWITCHING TO 2 AMPS SPDT,DPDT CONTACTS W60HE1S Recognized Component mark for Canada and the United States. W60HE2S C US UL Recognized File No. E52197 The Class 60 Miniature high reliability industrial grade relay has excellent RF switching characteristics. OUTLINE DIMENSIONS DIMENSIONS SHOWN IN "INCHES" AND (MILLIMETERS) 1.10 Max (27.9) .570Max (14.4) ACTUAL SIZE FIGURE "A" TOP VIEW SHOWN AT ACTUAL SIZE ON A 0.1 GRID W60HE1S .010 (0.25) .175 Max (4.45) .025 SQ. PINS (0.64) .092 (2.34) .040 DIA (1.01) TYP. W60HE2S .600 Max (15.2) .040 DIA (1.01) TYP. 1.10Max (27.9) CIRCUIT DIAGRAMS .570Max (14.4) FIGURE "B" BOTTOM VIEW SPDT .010 (0.25) .175 Max (4.45) .025 SQ. PINS (0.64) .105Max (2.67) DPDT .895 Max (22.7) PAGE 55 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 MINIATURE P.C. BOARD RELAY MOUNTABLE ON 0.100 GRID CLASS 60 SPECIFICATIONS CLASS 60 COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Nominal power: Max. coil dissipation: Coil Resistance CONTACTS Contact Material: Contact Resistance: 80% of Nominal Voltage or less 10% of nominal voltage or more 120% of nominal voltage, duty cycle 100% 327mW max. min. sensitivity: 200 mW 0.75 Watt ±10% Measured @ 25˚C Gold Clad Silver Palladium. Initial 50 Milliohms @ 6VDC, 10mA 100 Milliohms max., After life: 200 mΩ Low Level: 50uA- 50mV, SPDT: 2A-24VDC, 2A-120VAC, DPDT: 2A-24VDC, 0.6A-100VAC, Contact Rating: TIMING Operate Time: Release Time: Contact bounce: 4.0 mS Max. @ Nominal Voltage. 10.0 mS Max. @ Nominal Voltage. 2.5 mS operate, 5.0 mS release DIELECTRIC STRENGTH All Mutually Insulated Points: Surge Test: Insulation Resistance: TEMPERATURE Operating: 500 VAC for 1 Minute, 1 Milliamp max. leakage, or 600VAC for 1 Second, 1 Milliamp leakage. Meets FCC 68.302 ( 1500V Surge ) and 68.304 ( 1000V Dielectric ). 500 VDC Exceeds 1000 Megohms. -35˚C to +70˚C VIBRATION RESISTANCE Functional: 15g's, 10 to 2000Hz, (No contact opening greater than 10µS) SHOCK RESISTANCE Functional: Mechanical: 50g's, 6mS Max. Contact Chatter Destructive 50g's. LIFE Electrical (Rated Load): Mechanical (No Load): 100,000 Operations Rated Load. 100 Million Operations MISCELLANEOUS Terminal Finish: Terminals are solder Coated to provide excellent solderability. Max. exposure to soldering temperature is 5 seconds @ 250˚C. Any Plastic. SPDT-5.5 g's, DPDT- 9 g's approx. Operating Position: Enclosure: Weight: COIL Measured @ 25˚C PART NUMBERS FIGURE "A" W60HE1S-5DC W60HE1S-12DC W60HE1S-24DC W60HE1S-48DC FIGURE "B" W60HE2S-5DC W60HE2S-12DC W60HE2S-24DC W60HE2S-48DC Contact Nominal Configu- Input ration Voltage CROSS REFERENCE Resis- Pull-in TO Power tance POTTER & BRUMFIELD (Ohms) (mW) SPDT SPDT SPDT SPDT 5VDC 12VDC 24VDC 48VDC 75 440 1550 5250 200 200 200 200 R50E2Y1-5V R50E2Y1-12V R50E2Y1-24V R50E2Y1-48V DPDT DPDT DPDT DPDT 5VDC 12VDC 24VDC 48VDC 75 440 1550 5250 200 200 200 200 R50E2Y2-5V R50E2Y2-12V R50E2Y2-24V R50E2Y2-48V PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 56 CLASS MINIATURE 12 AMP EPOXY SEALED PC BOARD RELAY 178 CLASS 178 5 AMP AND 12 AMP SPDT CONTACTS. EPOXY SEALED. CLASS "B" INSULATION SYSTEM. Recognized Component mark for Canada and the United States. C US UL Recognized File No. E164066 WITHSTANDS THE VAPOR AND SPRAY CLEANING OF MOST FLUXING SYSTEMS. TERMINALS ARE SOLDER COATED TO PROVIDE EXCELLENT SOLDERABILITY. ACTUAL SIZE UL CONTACT LOAD RATINGS 5 AMP RELAY STYLE OPERATIONS LOAD 100,000 5A @125V AC 100,000 5A @250V HP 25,000 1/4 @ 120V 25,000 N.C. 1/4 @ 120V 25,000 120V TV-3 TV-5 125VA @ 120V 25,000 VA DC 100,000 5A @ 30V DC MOTOR 5A,120VAC,pf=0.5 100,000 LOAD 12 AMP RELAY STYLE OPERATIONS LOAD 6,000 12A @ 120V 100,000 10A @ 125V 100,000 10A @ 250V 10A, 1/4 @ 120V 100,000 N.O. 10A, 1/4 @ 250V 25,000 10A, 1/4 @ 120V 90,000 N.C. 25,000 125V 6,000 12A @ 28V 100,000 N.C* 10A @ 30V - PC BOARD LAYOUT ( BOTTOM VIEW ) .090 (2.29) .100 (2.54) .472 (12.0 .236 (6.0) .079 (2.0) .480 (12.2) .044 Dia. (1.1) (5 Holes) *N.0. CONTACT 25,000 @ 30 VDC OUTLINE DIMENSIONS Dimensions are in "INCH" and ( MILLIMETERS ) .650 Max (16.5) WIRING DIAGRAM ( BOTTOM VIEW ) PIERCE THRU VENT HOLE 2 3 v .620Max. (15.7) 1 ^ 5 .012 (.30) 4 SPDT .012 (.30) .039 (.99) PAGE 57 .039 (.99) .890 Max (22.5) .140 Typical (3.6) .016 (.40) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, Document 100 CLASS MINIATURE 12 AMP EPOXY SEALED PC BOARD RELAY 178 SPECIFICATIONS CLASS 178 COIL Pull-in Voltage: Dropout Voltage: Maximum Voltage: Insulation system: Coil Resistance: Duty: 75% of Nominal Voltage or less 10% of nominal Voltage or more. 110% of nominal voltage Class "B" (130˚C per UL std. 1446) ±10% @ 25˚C Continuous CONTACTS Contact Configuration: Contact Material: Contact Resistance: Minimum Load: SPDT Silver Cadmium Oxide 100 Milliohms @ 5VDC & 1 Amp Max. 100mA @ 12VDC TIMING Operate Time: Release Time: Bounce Time (typical): 20 mS Max. @ Nominal Voltage. 10mS Max. @ Nominal Voltage. Operate: 1ms, typ., Release: 4 ms, typ. DIELECTRIC STRENGTH Contacts to Coil: Across open Contacts: Insulation Resistance: 1500 VAC for 1 Minute or 1800 VAC 1 Sec 750 VAC for 1 Minute or 800 VAC 1 Sec . 100 Megohms M in. @ 500 VDC TEMPERATURE Operating: -40˚C to +70˚C VIBRATION RESISTANCE Functional: 10 to 55Hz Dual Amplitude -1.5 mm SHOCK RESISTANCE Functional: 10g's for 11mS (No Contact Opening >100 uS LIFE EXPECTANCY Electrical (Rated Load): Mechanical (No Load): 100,000 Operations 10 Million Operations MISCELLANEOUS Terminal Finish: P.C. Terminals are solder Coated and Epoxy free to provide excellent solderability. Max. exposure to soldering temperature is 6 seconds @ 300˚C. Any Plastic, Epoxy sealed, suitable for Automatic Circuit Board Processing. After cleaning process, pierce a small hole in cover for venting. 0.42 oz. (12) grams approximately. Operating Position: Enclosure: Weight: PART NUMBERS CONTACT RATING COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL INPUT POWER RESISTANCE VOLTAGE (mW) (OHMS) CROSS REFERENCE TO W178RE1-5DC W178RE1-12DC W178RE1-24DC 5 AMPS 5 AMPS 5 AMPS 5VDC 12VDC 24VDC 70 400 1600 400 400 400 POTTER & BRUMFIELD T70L5D131-5VDC T70L5D131-12VDC T70L5D131-24VDC W178URE1-5DC W178URE1-12DC W178URE1-24DC 12 AMPS 12 AMPS 12 AMPS 5VDC 12VDC 24VDC 70 400 1600 400 400 400 T70L5D164-5VDC T70L5D164-12VDC T70L5D164-24VDC IDEC OMRON G5L-114P-PS-DC5 G5L-114P-PS-DC12 G5L-114P-PS-DC24 RCN1V-5G-DC5V RCN1V-5G-DC12V RCN1V-5G-DC24V RCN1V-10G-DC5V G5LE-114P-PS-DC5 RCN1V-10G-DC12V G5LE-114P-PS-DC12 RCN1V-10G-DC24V G5LE-114P-PS-DC24 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, Document 100 PAGE 58 CLASS MINIATURE ENCLOSED PC BOARD RELAY - 3 TO 10 AMP 49 CLASS 49 RELAY Only 1.1 cubic inches. Variety of mounting configurations. Printed circuit terminals. Tapped mounting holes (49R1C4). TV 5 rating available. Standard pilot duty 240 VAC. Magnetic motor controller rating 1/3 Hp at 120VAC. LOW LEVEL TO 10 AMPS. PRINTED CIRCUIT OR BRACKET MOUNTING. UL Recognized File No. E52197 49RE1C2- 49R1C4- OUTLINE DIMENSIONS (Actual Size) ALL DIMENSIONS ARE IN INCHES AND MILLIMETERS Recommended P.C. board holes .067 dia.(1.7) ALL TERMINALS ARE .056 X .025 (1.42 X 0.64) 49RE1C1- STYLE RE1C1 STYLE RE1C2 .759 Max. (19.3) .759 Max. (19.3) 1.25 Max. (31.7) 1.25 Max. (31.7) 1.14 Max. (29.1) 1.14 Max. (29.1) .186 typ. (4.72) .210 (5.3) .593 (15.0) .310 (7.8) .453 (11.5) .097 (2.5) .210 (5.3) .310 (7.8) .313 (7.9) .150 (3.8) .843 (21.4) .379 (9.63 .546 (13.8 .594 (15.0) 1.015 (25.7) .915 (23.2) .687 (17.4) STYLE R1C4 1.225 (31.1) .562 (14.2) .328 (8.3) WIRING DIAGRAMS (BOTTOM VIEW) STYLE RE1C1 R1C4 1.34 Max. (34.1) .210 (5.3) .131 (.33) STYLE RE1C2 1.14 Max. (29.1) .310 (7.8) 4-40 Tapped holes (2 Req.) .313 (7.9) .843 (21.4) .150 (3.8) SPDT SPDT .759Max. (19.3) PAGE 59 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 MINIATURE ENCLOSED PC BOARD RELAY - 3 TO 10 AMP CLASS 49 SPECIFICATIONS CLASS 49 COIL Pull-in Voltage: VG, VW adj. (DC) = 75% , VF, VG adj. (AC) = 80%,of nominal coil voltage or less. 10% of actual pull-in or more 120% Max. Continuous ±10% Dropout voltage: Max. coil voltage Duty: Resistance: CONTACTS Contact Configuration: Contact Material: Contact Resistance: Contact Rating: Pilot Duty: TIMING Operate: Release Time: SPDT Silver Cad Oxide (5, 10 Amp), 3 Amp (Silver, Gold Plated). 100 Milliohms Max. initial Value @ 6 Vdc, 1 Amp 5 and 10 Amp @ 120/240 AC, 3 Amp @ 120 VAC, 28 VDC resistive. Motor load: 1/3 Hp @120VAC, 10 Amp only. TV 3 SPST-NO, SPST-NC, SPDT TV 5 SPST-NO, (10 Amp only). SPST-NO, SPST-NC, SPDT B300 10 mS typical (25 mS max.) 7mS typical (10 mS max.) PART NUMBERS PRINTED CIRCUIT BOARD MOUNTING SPDT, 3 AMP STYLE RE1C1 W49RE1C1VG-3DC-SIL W49RE1C1VG-5DC-SIL W49RE1C1VG-12DC-SIL W49RE1C2VF-6DC-SIL W49RE1C2VF-12DC-SIL W49RE1C2VF-24DC-SIL SPDT, 5 AMP STYLE RE1C1 AND RE1C2 W49RE1C1VG-5DC-SCO W49RE1C1VG-12DC-SCO W49RE1C1VG-24DC-SCO W49RE1C2VF-6DC-SCO W49RE1C2VF-12DC-SCO W49RE1C2VF-24DC-SCO SPDT, 10 AMP STYLE RE1C1 W49RE1C1VW-5DC-SCO W49RE1C1VW-12DC-SCO W49RE1C1VW-24DC-SCO SOLDER TERMINALS, BRACKET MOUNTING DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Coil to frame: Insulation Resistance: 1,500 V rms 500 V rms 1,500 V rms 1000 mΩ min. @ 500 VDC TEMPERATURE Operating: Storage: -55˚C to +85˚C -55˚C to +130˚C VIBRATION RESISTANCE Functional: 10 to 55 Hz @ 1.65mm Displacement SHOCK RESISTANCE Functional: Mechanical: 10 g's 100 g's LIFE Electrical (Rated Load): Mechanical No Load): 100,000 Operations. . 50,000, 000 Operations. MISCELLANEOUS Soldering temperature: Operating position: Enclosure: Weight: 270˚C (518˚F) max. for 5 seconds max.. Any. Dust cover. 42 Grams, 1.5 oz approximately. CROSS REFERENCE COIL Measured @ 25˚C Nominal Input Voltage Nominal Resistance (Ohms) Pull-in Power (mW) 3 VDC 5/6 VDC 12 VDC 6 VDC 12 VDC 24 VDC 90 235 1350 410 1640 6560 60 60 60 56 56 56 5/6 VDC 12 VDC 24 VDC 6 VDC 12 VDC 24 VDC 235 1350 5400 410 1640 6560 60 60 60 56 56 56 5/6 VDC 12 VDC 24 VDC 100 600 2400 135 135 135 5/6 VDC 12 VDC 235 1350 60 60 5/6 VDC 24 VDC 100 2400 135 135 GUARDIAN CORNELL DUBILIER 653-3K 653-6K 653-12K 1345-1C-5DC 1345-1C-12DC 1345-1C-24DC 603-6B 603-12B 603-24B 613-6B 613-12B 613-24B SPDT, 5 AMP- STYLE R1C4 W49R1C4VG-5DC-SCO W49R1C4VG-12DC-SCO SPDT,10 AMP W49R1C4VW-5DC-SCO W49R1C4VW-24DC-SCO PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 60 CLASS MINIATURE EPOXY SEALED PC BOARD POWER RELAY 76 CLASS 76 5, 10 and 16 AMP. CONTACT RATINGS EPOXY SEALED, IMMERSION CLEANABLE MEETS 8mm SPACING 5KV DIELECTRIC UL Recognized File No. E13224 CONTACT LOAD RATINGS FIGURE "B" FIGURE "A" FIGURE "C" DPDT (5 AMP) 5AMP @ 250VAC RES. 5AMP @ 30VDC 1/4HP @ 250VAC SPDT (10AMP) 10AMP @ 250VAC RES. 10AMP @ 30VDC 1/3HP @ 250VAC SPDT (16AMP) 16AMP @ 240VAC RES. 16AMP @ 24VDC 1/2HP @ 250VAC OUTLINE DIMENSIONS (Actual Size) All Dimensions are in inches and (millimeters) .512 Max. (13.0) 1.142 Max. (29.0) PIERCE THRU VENT HOLE .811Max. (20.6) .138 (3.5)Max. WIRING DIAGRAM (BOTTOM VIEW) FIGURE "A" FIGURE "B" FOOT PRINT FOR 70-475 SOCKET FIGURE "C" FOOT PRINT FOR 70-475 SOCKET FOOT PRINT FOR 70-478 SOCKET DRILLING PLAN (BOTTOM VIEW) .059 (1.5) .400 (10.1) .400 (10.1) .300 (7.62) .795 (20.19) FIGURE "A" .039 Dia. (1.0) .059 (1.5) .059 (1.5) .795 (20.19) .300 (7.62) .795 (20.19) FIGURE "B" .039 Dia. (1.0) .300 (7.62) .28 (7.11) FIGURE "C" .039 Dia. (1.0) SEE SECTION 10 FOR MATING SOCKETS PAGE 61 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS MINIATURE EPOXY SEALED PC BOARD POWER RELAY 76 SPECIFICATIONS CLASS 76 COIL Pull-in Voltage: Dropout Voltage: Nominal Power: Coil Resistance DC-75% of Nominal Voltage or less 5% of Nominal Voltage or More 600 mW(1 pole) 800 mw (2 pole )Approx.. ±10% Measured @ 20˚C CONTACTS Contact Material: Contact Resistance: Max.cycle rate: Minimum Switching Load: TIMING Operate Time: Release Time: Bounce Time: (Mean Value) DIELECTRIC STRENGTH Contacts to Coil: Across Open Contacts: Creepage & Clearance Insulation Resistance: Silver Cadmium Oxide 100 Milliohms Max. 30 Operations per Minute @ rated Load. 10 VDC @ 10 mA 15 mS Max. @ Nominal Voltage. 10 mS Max. @ Nominal Voltage. 1.2 mS Approx. TEMPERATURE Operating: Humidity: -30˚C to +70˚C 45 - 85% RH VIBRATION RESISTANCE Functional: 10 to 55 Hz Dual Amplitude 1.5mm SHOCK RESISTANCE Functional: Mechanical: 10 g's Min 100 g Min. LIFE Electrical (Rated Load): Mechanical (No Load): 100,000 Operations min. 10,000,000 Operations min. MISCELLANEOUS Operating position: Enclosure: 5000 V rms, for 1 Minute 1000 V rms, for 1 Minute 8 Millimeters Min. Coil & Contacts 500VDC Exceeds 100 Megohms Any Epoxy sealed for protection during automatic wave soldering & cleaning process. After cleaning process, pierce a small hole in cover for venting. 13 Grams approx. Weight: FIG. COIL Measured @ 20˚C NOMINAL Nominal CONTACT CONTACT Resistance CONFIGUINPUT RATING (Ohms) RATION VOLTAGE W76EURCPCX-14 W76EURCPCX-15 W76EURCPCX-16 W76EURCPCX-17 W76EURCPCX-18 "C" "C" "C" "C" "C" 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC 47 68 275 1,100 4,170 SPDT SPDT SPDT SPDT SPDT 10 AMP 10 AMP 10 AMP 10 AMP 10 AMP RKS-5DG-05 RKS-5DG-06 RKS-5DG-12 RKS-5DG-24 RKS-5DG-48 G2R-14-DC5 G2R-14-DC6 G2R-14-DC12 G2R-14-DC24 G2R-14-DC48 JW1FEN-DC5V JW1FEN-DC6V JW1FEN-DC12V JW1FEN-DC24V JW1FEN-DC48V W76EURCPCX-61 W76EURCPCX-62 W76EURCPCX-63 W76EURCPCX-64 "A" "A" "A" "A" 5 VDC 6 VDC 12 VDC 24 VDC 47 68 275 1,100 DPDT DPDT DPDT DPDT 5 AMP 5 AMP 5 AMP 5 AMP RKS-11DG-05 RKS-11DG-06 RKS-11DG-12 RKS-11DG-24 G2R-24-DC5 G2R-24-DC6 G2R-24-DC12 G2R-24-DC24 JW2EN-DC5V JW2EN-DC6V JW2EN-DC12V JW2EN-DC24V W76EURCPCX-146 W76EURCPCX-147 W76EURCPCX-148 W76EURCPCX-149 W76EURCPCX-150 "B" "B" "B" "B" "B" 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC 47 68 275 1,100 4,170 SPDT SPDT SPDT SPDT SPDT 16 AMP 16 AMP 16 AMP 16 AMP 16 AMP RKS-5DW-05 RKS-5DW-06 RKS-5DW-12 RKS-5DW-24 RKS-5DW-48 G2R-1-E-DC5 G2R-1-E-DC6 G2R-1-E-DC12 G2R-1-E-DC24 G2R-1-E-DC48 PART NUMBERS CROSS REFERENCE POTTER & BRUMFIELD OMRON AROMAT PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 62 CLASS ENCLOSED MINIATURE 2 POLE RELAY 1330 & 1335 SPACE SAVING DPDT, P.C. BOARD RELAY AC OR DC OPERATED COIL. RATED: 5 AMPS RESISTIVE, 3 AMPS INDUCTIVE ! W NE Recognized Component mark for Canadian and the United States. C US PENDING UL Recognized File No. E52197 SPECIFICATIONS CLASS 1330 & 1335 MANUFACTURED UNDER QUALITY SYSTEM COIL Pull-in Voltage: Dropout: Max. Voltage: Coil Resistance: Duty: 75% of Nominal Voltage or less for AC or DC Coils DC -10% min.or more. 110% ±10% @ 25˚C Continuous CONTACTS Contact Configurations: Contact Material: Contact Resistance: DPDT Silver Cadmium Oxide, .93 Dia. (2.36). 100 Milliohms Max. Contact Rating: UL RATED - 5 Amperers @ 120 VAC resistive NOT UL RATED - 30 VDC resistive, 3 Amperes Inductive, 1/8 Hp @ 120 VAC. ISO 9002 & QS 9000 TIMING Operate Time: Release Time: 20mS Max. AC, 15 mS Max. DC @ Nominal Voltage, 25˚C. 20mS Max. AC, 15 mS Max. DC @ Nominal Voltage, 25˚C. DIELECTRIC STRENGTH Coil to Frame: Across Open Contacts: Contact to Frame: Insulation Resistance: 1500 V rms 500 V rms 1500 V rms 1500 Megohms Min. TEMPERATURE Ambient Temperature: -45˚C to + 70˚C @ Rated Operation. LIFE EXPECTANCY Mechanical AC operated Device in excess of 50 million operations DC operated devices, in excess of 100 million operations. 100,000 Operations Min. (at rated Resistive load). Electrical (rated Load): MISCELLANEOUS Operating Position: Insulating Material: Enclosure: Weight: 1.075 Max. (27.3) .200 Max. .728 Max. (18.5) 1 2 3 4 5 6 7 8 9 10 .020 Max. (.5) Ref. Any. Molded parts are diallyl phthalate for higher arc resistance. Clear heat resistant Polycarbonate Dust Cover. Approximately 3/4 oz. P.C. BOARD LAYOUT .728 Ref (18.5) .350 (8.9) .189 (4.8) .905 Max. (23) .157 (4) CIRCUIT DIAGRAM .123 (3.1) 11 .052 Typ. (1.31) .905 Ref (23) .067 Dia. (1.7) 8 PL PART NUMBERS Nominal Input Voltage AC OPERATED COILS W1330P-2C-24A 24 VAC W1330P-2C-120A 120 VAC DC OPERATED COILS W1335P-2C-12D 12 VDC W1335P-2C-24D 24 VDC .354 .197(5) (9) .551 (14) .197(5) .231 Ref (5.9) Coil Measured at 25˚C CROSS REFERENCE Nominal Nominal TO Resistance Power GUARDIAN (Ohms) 245 Ω 5400 Ω 1.2 VA 1.2 VA 1330P-2C-24A 1330P-2C-120A 125 Ω 500 Ω 1.2 W 1.2 W 1335P-2C-12D 1335P-2C-24D PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PAGE 63 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 S E C T I O N 3 3 REED RELAYS FOR PRINTED CIRCUIT BOARD APPLICATIONS 4 VA TO 100 VA. COAXIAL RELAYS FOR R.F. SWITCHING. Page 64 Magnecraft Struthers-Dunn PRINTED CIRCUIT BOARD REED RELAYS "DIP" "SIP" RELAY SERIES 131 MERCURY 101 NEW! DPDT DIP SPDT UP UP DPDT EPOXY MOLDED CONSTRUCTION. FEATURES STANDARD 0.1 GRID SPACING. AVAILABLE WITH OR WITHOUT SUPPRESSION DIODE ACROSS COIL.. . SOCKET AVAILABLE SEE SECTION 10 SPDT - EPOXY MOLDED CONSTRUCTION. DPDT ENCAPSULATED CONSTRUCTION. ENCAPSULATED CONSTRUCTION OR EPOXY MOLDED WITH SIDE TERMINALS STANDARD 0.1 GRID SPACING. STANDARD 0.1 GRID OR OPTIONAL 0.15 SPACING. AVAILABLE WITH SUPPRESSION DIODE ACROSS COIL. CLASS 107 PROVIDES 4 HOOK- UP PINS TO COIL.. NON LATCHING SINGLE COIL OR SINGLE & DUAL COIL MAGNETIC LATCHING. ELECTROSTATIC SHIELD OPTIONAL. ELECTROSTATIC SHIELD OPTIONAL. ENCAPSULATED CONSTRUCTION. STANDARD 0.1 GRID OR OPTIONAL 0.15 SPACING. POSITION SENSITIVE VERTICAL MOUNTING. EXCELLENT FOR LOW LEVEL SWITCHING. ELECTROSTATIC SHIELD OPTIONAL. CONTACT CONFIGURATION: SPST-NO, SPST-NC SPST-NO, or NC, SPDT, DPDT 1 to 3PST-NO, SPST-NO, DPST-N0 MAXIMUM CONTACT RATING: MAX. SWITCHING 0.5 AMPS or 200 VDC @ 10 VA MAX. SWITCHING 0.5 AMPS or 100 VDC @ 4VA -10VA MAX. SWITCHING 0.5 AMPS or 200 VDC @ 10 VA MAX. SWITCHING 2.0 AMPS or 500 VDC @ 50 VA MAX.CARRY LOAD 1.5 AMPS MAX.CARRY LOAD 1.5 AMPS MAX.CARRY LOAD 2.0 AMPS MAX.CARRY LOAD 3.0 AMPS CONTACT MATERIAL: RHODIUM RHODIUM RHODIUM 100 MILLIOHMS (INITIAL) 100 MILLIOHMS (INITIAL) 100 MILLIOHMS (INITIAL) 1500 V rms 1000 V rms 500 VDC DC - VOLTAGE RANGE: 5, 12, 24 VDC 5, 12, 24 VDC 5, 12, 24 VDC 5, 12, 24 VDC NOMINAL POWER: 270 mW Max. 650 mW Max. 380 mW Max. 625 mW Max. CONTACT RESISTANCE: MERCURY (Hg) 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: 1000 V rms COIL DATA GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: TIMING VALUES MAX. OPERATE: MAX. RELEASE: - 40˚ C to + 85˚ C 1 MILLISECONDS 1 MILLISECONDS LIFE MECHANICAL: ELECTRICAL: 100 MILLION OPERATIONS 50 MILLION OPERATIONS H DIMENSIONS: W L .290 X .280 X .750 MOUNTING POSITION: APPLICATION DATA: PAGE NUMBER: PAGE 65 ANY PAGE 68, 69 PAGE 70 - 40˚ C to + 85˚ C 1 MILLISECONDS 1 MILLISECONDS 100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L .275 X .300 X .750 .338 X .393 X .750 (DPDT) ANY PAGE 71 thru 75 - 37˚ C to + 85˚ C - 40˚ C to + 85˚ C 2 MILLISECONDS 2 MILLISECONDS 1 MILLISECONDS 1 MILLISECONDS 100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L .355 X .400 to .900 X 1.15 ANY 100 MILLION OPERATIONS 40 MILLION OPERATIONS H W L .355 X PG.39 X 1.15 VERTICAL ± 15˚ MINIATURE REED SPECIFICATIONS: PAGE 77 PAGE 76 PAGE 78 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 Magnecraft Struthers-Dunn MINIATURE REED RELAYS 104 134 MERCURY 193 MRR & RR MR-Y UP DUST COVER STANDARD. DUST COVER STANDARD. ENCAPSULATED CONSTRUC- ENCAPSULATED CONTION OPTIONAL STRUCTION OPTIONAL DUST COVER STANDARD. ENCAPSULATED CONSTRUCTION OPTIONAL STANDARD 0.1 GRID OR OPTIONAL 0.15 GRID SPACING AVAILABLE. STANDARD 0.1 GRID OR OPTIONAL 0.15 SPACING AVAILABLE. STANDARD 0.1 GRID OR OPTIONAL 0.15 GRID SPACING. POSITION SENSITIVE. VERTICAL MOUNTED. UP TO 4PDT OR 6PST CONTACT ARRANGEMENTS. EPOXY MOLDED AXIAL LEAD REED RELAY EPOXY MOLDED. STANDARD 0.1 GRID OR OPTIONAL 0.15 GRID SPACING AVAILABLE. EXTERNAL MAGNETIC SHIELDING FIXED TO BODY. MAGNETIC SHIELDING. SOLID LEADS END TERMINALS. TTL COMPATIBLE. SPDT, DPDT SPDT, DPDT 1 to 4PDT, 1 to 6PST 1 & 2PST-NO or NC SPDT, DPDT 1 to 12PST-NO 0r NC MAX SWITCHING 0.25 AMPS or 100VDC @ 4 VA MAX SWITCHING 1.0 AMPS or 500VDC @ 50 VA MAX SWITCHING 0.5 AMPS or 200VDC @ 10 VA MAX SWITCHING 0.5 AMPS or 200VDC @ 10 VA MAX SWITCHING 0.5 AMP or 200VDC @ 10 VA MAX.CARRY LOAD 0.5 AMP MAX.CARRY LOAD 2.0 AMP. MAX.CARRY LOAD 2.0 AMP MAX.CARRY LOAD 1.5 AMP MAX.CARRY LOAD 1.5 AMPS RHODIUM MERCURY RHODIUM RHODIUM RHODIUM 200 MILLIOHMS (INITIAL) 100 MILLIOHMS (INITIAL) 200 MILLIOHMS (INITIAL) 200 MILLIOHMS (INITIAL) 200 MILLIOHMS (INITIAL) 500 V rms 1000 V rms 500 V rms 500 V rms 500 V rms 5, 12, 24 VDC 5, 12, 24 VDC 5, 12, 24 VDC 5, 12, 24 VDC 6 to 48 VDC 626 mW Max. 620 mW Max. 1030 mW Max. 450 mW Max. 400 mW Max. -40˚C to + 85 ˚C -37 ˚C to + 85 ˚C -40 ˚C to + 85 ˚C -40˚C to + 85 ˚C -40 ˚C to + 85 ˚C 1 MILLISECONDS 1 MILLISECONDS 2 MILLISECONDS 3 MILLISECONDS 1 MILLISECONDS 1 MILLISECONDS 5 MILLISECONDS 5 MILLISECONDS 100 MILLION OPERATIONS 50 MILLION OPERATIONS H W L .355 X .5 to .7 X 1.15 1 MILLISECONDS 1.5 MILLISECONDS 100 MILLION OPERATIONS 40 MILLION OPERATIONS H W L 355 X .5 to .5 X 1.15 100 MILLION OPERATIONS 100 MILLION OPERATIONS 200 MILLION OPERATIONS 50 MILLION OPERATIONS 50 MILLION OPERATIONS 10 MILLION OPERATIONS H W L .355 X .4 to .9 X 1.15 ANY VERTICAL ± 15˚ ANY PAGE 79 PAGE 80 PAGE 81, 82 L DIAMETER .312 X 0.4 X .950 .655 X 1.875 ANY ANY H W PAGE 83, 84 PAGE 85, 86 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 66 Magnecraft Struthers-Dunn P.C. BOARD REED RELAYS & COAXIAL RELAY SERIES FEATURES 102 120 COAXIAL OPEN END CONSTRUCTION WITH METAL COVER OPEN END CONSTRUCTION DRY REED MAGNETIC SHIELDING SWITCHING UP TO 3.0 AMPS @ 250 VDC. 150 WATT SWITCHING UP TO 470 MHz. RG58C/U CABLE, 12" LONG STANDARD. 50 OHM IMPEDANCE 1 FORM C (DPDT) R.F. SWITCHING CONTACTS. RRN 0.2 GRID SPACING SINGLE PIECE GLASS FILLED BOBBIN AND TERMINALSUPPORT METAL COVER/SHIELD STANDARD 0.2 GRID SPACING. VARIOUS CONTACT ARRANGEMENTS. CONTACT DATA CONTACT CONFIGURATION: MAXIMUM CONTACT RATING: See Catalog Page SPST-NO SPDT MAX SWITCHING 0.5 or 1.0 AMP or 250VDC @ 10 or 15 VA MAX SWITCHING 1.0 or 3.0 AMPS or 250VDC @ 15 or 100 VA 150 Watts up to 470 MHz MAX.CARRY LOAD 2 or 3.5 AMPS CONTACT MATERIAL: CONTACT RESISTANCE: RHODIUM RHODIUM 200 MILLIOHMS (INITIAL) 200 MILLIOHMS (INITIAL) SILVER ALLOY GOLD FLASHED 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: 1500 V rms 1500 V rms 1,500 V rms COIL DATA DC - VOLTAGE RANGE: NOMINAL POWER: 6 to 48 VDC 12, 24 VDC 12 VDC 700 mW Max. 800 mW Max 1.44 Watts GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: TIMING VALUES MAX. OPERATE: MAX. RELEASE: LIFE MECHANICAL: ELECTRICAL: DIMENSIONS MOUNTING POSITION PAGE NUMBER PAGE 67 -40 ˚C to + 85 ˚C 6 MILLISECONDS 6 MILLISECONDS 200 MILLION OPERATIONS 10 MILLION OPERATIONS H W L .641 X 0.74 X 2.50 ANY PAGE 87, 88 -40 ˚C to + 85 ˚C 5 MILLISECONDS 6 MILLISECONDS 100 MILLION OPERATIONS 20 MILLION OPERATIONS H W L 0.65 X 0.76 X 2.67 ANY PAGE 89 - 55˚ C to + 65˚ C 15 MILLISECONDS 7 MILLISECONDS 100,000 OPERATIONS 5 MILLION OPERATIONS H W L .1.62 X.703 X 1.73 ANY PAGE 90 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 APPLICATION DATA REED RELAYS HOW REED RELAYS WORK MERCURY-WETTED CONTACT RELAYS. ( CONTINUED) The term reed relay covers dry reed relays and mercury-wetted contact relays, all of which use hermetically sealed reed switches. In both types, the reeds (thin, flat blades) serve multiple functions as conductor, contacts, springs, and magnetic armatures. DRY REED RELAYS Dry reed relays have become an important factor in the relay field. They have the advantage of being hermetically sealed and resistant to atmospheric contamination. They have fast operate and release times and when operated within their rated contact loads, have very long life. A typical dry reed switch capsule is shown in Figure 1. 123456 12345678901234567890123456 123456 123456 12345678901234567890123456 123456 123456 12345678901234567890123456 123456 123456 12345678901234567890123456 123456 123456 12345678901234567890123456 123456 123456 12345678901234567890123456 123456 Supporting Terminal Normally Open Contacts Glass Capsule Supporting Terminal Figure 1. Construction of Switch Capsule of Typical Dry Reed switch (SPST-NO) In the basic SPST-NO design, two opposing blades are sealed into a narrow glass capsule and overlapped at their free ends. The contact area is plated typically with rhodium to produce a low contact resistance when contacts are drawn together. The capsule is made of glass and filled with a dry inert gas and then sealed. The capsule is surrounded by an electromagnetic coil. When the coil is energized, the normally open contacts are brought together; when the coil voltage is removed, the blades separate by their own spring tension. Some reeds contain permanent magnets for magnetic biasing to achieve normally closed contacts (SPST-NC) or SPDT contact combinations. The current rating, which is dependent upon the size of the blade and the type and amount of plating, may range from low level to 1 amp. Effective contact protection is essential when switching loads other then dry resistive loads. MERCURY-WETTED CONTACT RELAYS. Mercury wetted contacts consist of a glass-encapsulated reed with its base immersed in a pool of mercury and the other end capable of moving between one or two stationary contacts. The mercury flows up the reed by capillary action and wets the contact surfaces of the moving end of the reed as well as the contact surfaces of the stationary contacts. A mercury to mercury contact is maintained in the closed position. The capsule is surrounded by an electromagnetic coil and operates in the same manner as a dry reed. Supporting 123456 123456 Leadwire UP OPERATING POSITION Glass Capsule Mercury pool 123456 123456 12345 123456 12345 123456 12345 12345 12345 12345 12345 12345 12345 12345 12345 Movable 12345 12345 contact blade 12345 12345 12345 12345 12345 12345 12345 12345 12345 12345 123456 123456 12345 12345 123456 12345 123456 123456 123456 Figure 2. Miniature Mercury-wetted contact switch (SPDT) Mercury wetted contacts are fast in operation and have relatively good load carrying capacity and long life. The mercury films are reestablished at each contact closure and contact erosion is eliminated.. The mercury films are stretchable, there is no contact bounce and because it is a mercury contact, the contact resistance is very low and ideal for low level switching applications. The disadvantages of this type of reed relay are the freezing point of mercury (-38˚C), poor resistance to shock and vibration and the need to mount the relay in a near vertical position. These relays are used for a variety of switching applications such as found in computers, business machines, machine tool control systems, and laboratory instruments. CONTACT COMBINATIONS. The switches used in dry reed relays provide SPST-NO, SPST-NC, SPDT contact combinations. The SPST-NO corresponds with the basic switch capsule design (Fig.1). The SPST-NC results from a combination of the SPST-NO switch and a permanent magnet strong enough to pull the contacts closed but able to open when coil voltage is applied to the relay coil. In typical true SPDT designs, the armature is mechanically tensioned against the normally closed contact, and is moved to the normally open contact upon application of a magnetic field. The SPDT contact combination can also be achieved by joining a SPST-NO switch with an appropriately adjusted SPST-NC switch, and jumping one side of both switches together to form the movable contact system. Latching contacts, defined as contacts which remain in the position to which they were driven, and staying in that position when coil power is removed from the relay coil. Latching switches are manufactured by using a SPST-NO contact, and biasing it with a permanent magnetic that is strong enough to hold the contacts closed, but not strong enough to hold the contact closed when coil power is applied to the coil. The switching process is than reversed by simply reversing the relay coil polarity to close the switch. MAGNETIC FIELDS Reed relays in general can be characterized as susceptible to the influences of external magnetic fields. It is important to keep reed relays at a proper distance from each other because of the possibility of magnetic-interaction between them. Proper magnetic shielding must be used to contain stray magnetic fields. When installing reed relays into equipment, one should be aware of the devices within that equipment which can produce magnetic fields. The relays being installed into that equipment should be positioned as far away as possible from any stray magnetic fields and should be shielded to prevent false operations. ELECTRICAL CHARACTERISTICS SENSITIVITY: The input power required to operate dry reed relays is determined by the sensitivity of the particular reed switch used, by the number of switches operated by the coil, by the permanent magnet biasing (if used), and the efficiency of the coil and the effectiveness of its coupling to the blades. Minimum input required to effect closure ranges from the very low milliwatt level for a single sensitive capsule to several watts for multipole relays. OPERATE TIME: The coil time constant, overdrive on the coil, and the characteristics of the reed switch determine operate time. With the maximum overdrive voltage applied to the coil, reed relays will operate in approximately the 200 microsecond range. When driven at rated coil voltage, usually the relays will operate at about one millisecond. RELEASE TIME: With the coil unsuppressed, dry reed switch contacts release in a fraction of a millisecond. SPST-NO contacts will open in as little as 50 microseconds. Magnetically biased SPST-NC and SPDT switches reclose from 100 microseconds to 1 millisecond respectively. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 68 REED RELAYS APPLICATION DATA ELECTRICAL CHARACTERISTICS (Continued) RELEASE TIME (Continued) If the relay coil is suppressed, release times are increased. Diode suppression can delay release times for several milliseconds, depending on coil characteristics, coil voltage, and reed release characteristics. CONTACT BOUNCE Dry reed contacts bounce on closure as with any other hard contact relay. The duration of bounce on a Dry reed switch is typically very short, and is in part dependent on drive level. In some of the faster devices, the sum of the operate time and bounce is relatively constant. As drive is increased, the operate time decreases with bounce time increasing. The normally closed contacts of a SPDT switch bounce more then the normally open contacts. Magnetically biased SPST-NC contacts exhibit essentially the same bounce characteristics as SPST-NO switches. NOISE Noise is defined as a voltage appearing between terminals of a switch for a few milliseconds following closure of the contacts. It occurs because the reeds (blades) are moving in a magnetic field and because voltages are produced within them by magnetostrictive effects. From an application standpoint, noise is important if the signal switched by the reed is to be used within a few milliseconds immediately following closure of the contacts. When noise is critical in an application, a peak-to-peak limit must be established by measurement techniques, including filters which must be specified for that particular switching application. ENVIRONMENTAL CHARACTERISTICS Reed relays are used in essentially the same environments as other types of relays. Factors influencing their ability to function would be temperature extremes beyond specified limits CONTACT RESISTANCE VIBRATION The reeds (blades) in a dry reed switch are made of magnetic material which has a high volume resistivity, terminal-to-terminal resistance is somewhat higher than in some other types of relays. Typical specification limits for initial resistance of a SPST-NO reed relay is 0.200 ohms max (200 milliohms). The reed switch structure, with so few elements free to move, has a better defined response to vibration than other relay types. With vibration inputs reasonably separated from the resonant frequency, the reed relay will withstand relatively high inputs, 20 g's or more. At resonance of the reeds, the typical device can fail at very low input levels. Typical resonance frequency is 2000 hz. INSULATION RESISTANCE SHOCK A dry reed switch made in a properly controlled internal atmosphere will have an insulation resistance of 1012 to 1013 ohms or greater. When it is assembled into a relay, parallel insulation paths reduce this to typical values of 109 ohms. Depending on the particular manner of relay construction, exposure to high humidity or contaminating environments can appreciably lower final insulation resistance. CAPACITANCE. Reed capsules typically have low terminal-to-terminal capacitance. However, in the typicall relay structure where the switch is surrounded by a coil, capacitance from each reed to the coil act to increase capacitance many times. If the increased capacitance is objectionable, it can be reduced by placing a grounded electrostatic shield between the switch and coil. Dry reed relays will withstand relatively high levels of shock. SPST-NO contacts are usually rated to pass 30 to 50 g's, 11 milliseconds, half sign wave shock, without false operation of contacts. Switches exposed to a magnetic field that keep the contacts in a closed position, such as in the biased latching form, demonstrate somewhat lower resistance to shock. Normally closed contacts of mechanically biased SPDT switches may also fail at lower shock levels. TEMPERATURE Differential expansion or contraction of reed switches and materials used in relay assemblies can lead to fracture of the switches. Reed relays are capable of withstanding temperature cycling or temperature shock over a range of at least -50˚C to + 100˚C. These limits should be applied to the application to prevent switch failure. DIELECTRIC WITHSTAND VOLTAGE CONTACT PROTECTION With the exception of the High-Voltage dry reed switches ( capsules that are pressurized or evacuated), the dielectric strength limitation of relays is determined by the ampere turn sensitivity of the switches used. A typical limit is 200 VAC. The dielectric withstand voltage between switch and coil terminals is usually 500 VAC. Tungsten lamp, inductive and capacitive discharge load are extremely detrimental to reed switches and reduce life considerably. Illustrated below are typical suppression circuits which are necessary for maximum contact life. FIGURE 3 THERMAL EMF Input Since thermally generated voltages result from thermal gradients within the relay assembly, relays built to minimize this effect often use sensitive switches to reduce required coil power, and thermally conductive materials to reduce temperature gradients. Latching relays, which may be operated by a short duration pulse, are often used if the operational rate is not changed for longer periods of time because coil power is not required to keep the relay in the on or off position after the initial turn on or turn off pulse. R Input R Initial turn-on current is generally 10 times higher than the rated operating current of the lamp. A current limiting resistor in series with the load, or a bleeder resistor across the contacts will suppress the inrush current. Thesesame circuits can be used with capacitive loads, as shown in Figure 3. FIGURE 4 Input Input DC inductive loads call for either a diode or a thyristor to be placed across the load. These circuits are necessary to protect the contacts when inductive loads are to be switched in a circuit, as shown in Figure 4. PAGE 69 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SIP SINGLE IN-LINE PACKAGE REED RELAY CLASS 117 "SIP" 0.5 AMP SWITCHING SPST-N.O. OR N.C. CONTACTS OUTLINE DIMENSIONS SPECIFICATIONS CLASS 117SIP Dimensions shown are in "INCHES" & (Millimeters) Package Material: Contact Material: Ambient Temperature: Dielectric Strength: Epoxy, molded Rhodium - 40˚C to + 85˚C 150 V rms Across open contacts 500 V rms all other points Insulation Resistance: 1000 Megohms Min. Capacitance: 1.0 pF typical coil to contacts Shock Resistance: 50 G's Vibration Resistance: 20 G's to 200 Hz 1 Millisecond Max. Operate Time: 1 Millisecond Max. Release Time: 50 Million operations , 5-10V @ 10 mA Life 100 Million operations no load .290 Max. (7.36) .750 Max. (19.5) .290 Max. (7.36).260 Max (6.60) .075 Max. (1.90) .020 Typ. (.51) .110 (2.79) Pin No. 1 Indicator .200Typ. (5.08) .600 (15.2) .030 Max. (.762) .140 Max. (3.55) .010 Typ. (.25) CONSULT FACTORY FOR COMPLETE PART NUMBER WITH REQUIRED OPTIONS MAXIMUM CONTACT RATING COIL Measured @ 25˚C CIRCUIT DIAGRAM TOP VIEW CROSS REFERENCE TO PART NUMBERS NOMINAL INPUT VOLTAGE W117SIP-1 5 4.0 0.5 500 50 3621A0500 JWS-117-1 W117SIP-3 12 9.6 1.0 1870 77 3621A1200 JWS-117-3 W117SIP-5 24 19.2 2.0 3200 180 3621A2400 JWS-117-5 W117SIP-22 5 4.0 0.5 500 50 - JWD-171-12 W117SIP-23 12 9.6 1.0 1200 120 - JWD-171-14 7 W117SIP-24 24 19.2 2.0 2200 270 - JWD-171-15 NOMINAL NOMINAL MAXIMUM MINIMUM RESISSWITCHING CONTINUOUS POWER PULL-IN DROPOUT TANCE CARRY CURRENT LOAD (mW) (OHMS) HAMLIN POTTER & BRUMFIELD SPST - N.O. 3 1 SPST - N.C. 1 3+ 5 5 7 SPST - N.O. WITH CLAMPING DIODE 10VA 0.5 AMP 200VDC 1.5 AMPS W117SIP-6 5 4.0 0.5 500 50 3621A0510 JWS-117-6 W117SIP-8 12 9.6 1.0 1870 77 3621A1210 JWS-117-8 24 W117SIP-10 7 3+ 1 5SPST - N.C. WITH CLAMPING DIODE 19.2 2.0 3200 180 3621A2410 JWS-117-10 1 3+ 5- 7 W117SIP-18 5 4.0 0.5 500 50 - JWD-171-17 W117SIP-25 12 9.6 1.0 1200 120 - JWD-171-19 W117SIP-26 24 19.2 2.0 2200 220 - JWD-171-30 NOTE: MAGNECRAFT FOOT PRINT IS IDENTICAL TO COMPETITOR PART NUMBERS SHOWN. COIL RESISTANCE MAY DIFFER SLIGHTLY FOR THE NOMINAL VOLTAGES SHOWN. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 63 CLASS 107 DUAL IN-LINE PACKAGE REED RELAY DIP 107 DIP RELAY EPOXY MOLDED PROVIDES 4 HOOK-UP PINS TO COIL. SPECIFICATIONS CLASS 107DIP Package Material: Contact Material: Ambient Temperature: Dielectric Strength: Insulation Resistance: Capacitance: Operate Time: Release Time: Shock Resistance: Vibration Resistance: Life 14 Operating Position: Weight: .300 (7.62) Epoxy, molded Rhodium - 40˚C to + 85˚C 150 V rms Across open contacts 500 V rms all other points 1000 Megohms Min. 2.0 pF typical coil to contacts 1 Milliseconds Max @ Nominal. 1 Milliseconds Max @ Nominal. 50 G's 20 G's to 200 Hz 50 Million operations at 5-10V @ 10mA 100 Million operations no load Any 1 gram approx. .100 typ. (2.54) 1 .750 Max. (19.05) .275 (6.98) .020 (0.51) .020 typ. (0.51) .010 (.254) .150 Typ. (3.81) .400 (10.1) .600 (15.2) COIL Measured @ 25˚C CIRCUIT DIAGRAM TOP VIEW RELAY PART NOMINAL MAXIMUM MINIMUM INPUT NUMBERS PULL-IN DROPOUT VOLTAGE MAX. CONTACT RATING NOMINAL NOMINAL MAXIMUM MAXIMUM RESISPOWER SWITCHING CONTINUOUS TANCE (mW) LOAD (OHMS) CARRY CURRENT CROSS REFERENCE TO POTTER & BRUMFIELD SPST - N.O. 14 13 9 8 W107DIP-1 5 3.8 0.5 500 50 W107DIP-3 12 9.0 1.0 1200 120 2 6 JWD-107-3 10VA 0.5 AMP 100 VDC 24 18.0 2.0 2200 260 W107DIP-5 5 3.8 0.5 500 50 JWD-107-5 W107DIP-7 12 9.0 1.0 1200 120 JWD-107-7 W107DIP-8 24 18.0 2.0 2200 260 - W107DIP-4 1 JWD-107-1 7 1.5 AMPS - SPST - N.O. WITH CLAMPING DIODE 14 13 9 8 + 1 2 6 7 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. All DIP configurations are available with Magnetic Shielding (internal) and /or Low level applications on special order. Contact factory for special part numbers. SEE SECTION 10 FOR MATING SOCKET PAGE 71 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 SPECIFICATIONS CLASS 172 & 172 DIPS DIP SPECIFICATIONS 171DIP & 172 (SPDT) Package Material: Contact Material: Ambient Temperature: Dielectric Strength: Epoxy, molded Rhodium or Mercury (as selected) - 40˚C to + 85˚C 150 V rms Across open contacts 500 V rms all other points 1000 Megohms Min. 1.0 pF typical coil to contacts 50 G's 20 G's to 200 Hz 1 Millisecond max. 1 Millisecond max. 50 Million operations, 5-10V @ 10mA 100 Million operations Low Level Insulation Resistance: Capacitance: Shock Resistance: Vibration Resistance: Operate Time: Release Time: Life 171 & 172 (SPDT) OUTLINE DIMENSIONS Dimensions shown are in "INCHES" & (Millimeters) 14 .300 (7.62) 1 .100 typ. (2.54) .750 Max. (19.05) .275 (6.98) .010 (.254) .020 (0.51) .020 typ. (0.51) .400 (10.1) .600 (15.2) .150 Typ. (3.81) SPECIFICATIONS 172DIP (DPDT) Package Material Contact Material: Coil Resistance: Contact Resistance: Ambient Temperature: Dielectric Strength:: Coil to contact: Insulation Resistance: Operate Time Release Time: Life: Plastic Rhodium ± 10% @ 20˚C 150 MΩ max. - 40˚C to + 85˚C 150 VDC min. 500 VDC min. 1000 Megohms Min. 0.7 Millisecond max. (including bounce) 1 Millisecond max. 50 million operations, 50V/50mA: 80 million operations, 10v/10mA: PACKAGE STYLE FOR W172 DIPS DPDT Dimensions shown are in "INCHES" & (Millimeters) PIN 1 LOCATION .393 ±.003 (10.0) .750 ±.003 (19.0) FOOTPRINT AND SCHEMATIC IS PIN FOR PIN EQUIVALENT TO FORMER DPDT MODELS .338 ±.003 (8.60) .125 ±.003 (3.20) 0.10 Typ (2.54) .600 ±.003 (15.24) .082 Typ. (2.09) .025 (.635) .046 Typ. (1.19) .300 ±.003 (7.62) WHEN SPACING DIP RELAYS, EXCEPT FOR THE LATCH VERSION, THE RELAYS REQUIRE 3/4 INCH SPACING FROM THE SIDE OF THE ADJACENT RELAYS. LATCH RELAYS REQUIRE 1 INCH SPACING BETWEEN ADJACENT RELAYS FROM END TO END AND CENTER LINE TO CENTER LINE. SEE SECTION 10 FOR MATING SOCKET WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 72 DUAL IN-LINE PACKAGE REED RELAY DIP MIL SPECIFICATION MIL-83516/1 AND /4 VERSIONS AVAILABLE CONSULT FACTORY MAXIMUM CONTACT RATING COIL Measured @ 25˚C CIRCUIT DIAGRAM TOP VIEW PART NUMBERS NOMINAL NOMINAL SWITCHING CONTINUOUS NOMINAL MAXIMUM MINIMUM RESISPOWE LOAD CARRY CURRENT INPUT TANCE DROPOUT PULL-IN (mW) VOLTAGE (OHMS) SPST - N.O. 14 13 CROSS REFERENCE TO HAMLIN POTTER & BRUMFIELD HE9 8 W171DIP-2 5 3.8 0.5 500 50 W171DIP-4 12 9.0 1.0 1200 120 W171DIP-5 24 18.0 2.0 2200 270 3.8 0.5 500 50 10VA 0.5 AMP 100VDC 1.5 AMPS 721A0500 - 721A1200 - 721A2400 JWD-171-5 721A0510 - 721A1210 - 721A2410 JWD-171-10 721B0500 JWD-171-12 721B1200 JWD-171-14 721B2400 JWD-171-15 721B0510 JWD-171-17 721B1210 JWD-171-19 721B2410 JWD-171-20 722A0500 JWD-171-21 722A1200 JWD-171-23 722A2400 JWD-171-24 722A0510 JWD-171-25 722A1210 JWD-171-27 722A2410 JWD-171-28 1 2 6 7 SPST - N.O. WITH CLAMPING DIODE 14 13 9 8 + 1 2 6 SPST - N.C. 14 13 9 W171DIP-7 5 W171DIP-9 12 9.0 1.0 1200 120 W171DIP-10 24 18.0 2.0 2200 270 W171DIP-12 5 3.8 0.5 500 50 8 12 9.0 1.0 1200 120 W171DIP-15 24 18.0 2.0 2200 270 1 2 6 7 SPST - N.C. WITH CLAMPING DIODE 14 13 9 8 5 W171DIP-17 3.8 0.5 500 50 + W171DIP-19 12 9.0 1.0 1200 120 W171DIP-20 24 18.0 2.0 22 00 270 W171DIP-21 5 3.8 0.5 125 125 9.0 1.0 500 300 24 W171DIP-24 1 2 6 7 DPST - N.O. WITH CLAMPING DIODE 18.0 2.0 2000 270 3.8 0.5 200 125 1 2 6 1.5 AMPS 10VA 0.5AMP 100VDC 1.5 AMPS 8 W171DIP-25 + 10VA 0.5 AMP 100VDC 1.5 AMPS 8 12 9 10VA 0.5 AMP 100VDC 7 W171DIP-23 14 13 1.5 AMPS 7 W171DIP-14 1 2 6 DPST - N.O. 14 13 9 10VA 0.5 AMP 100VDC 5 W171DIP-27 12 9.0 1.0 500 290 7 W171DIP-28 24 18.0 2.0 2200 270 10VA 0.5 AMP 100VDC 1.5AMPS PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 171DIP PAGE 73 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 DUAL IN-LINE PACKAGE REED RELAY COIL Measured @ 25˚C CIRCUIT DIAGRAM TOP VIEW PART NUMBERS NOMINAL MAXIMUM MINIMUM INPUT PULL-IN DROPOUT VOLTAGE MAGNECRAFT & STRUTHERS-DUNN - SPST-NO LATCHING 14 13 RESET 9 + 6 REFERENCE TO POTTER & BRUMFIELD 8 + 1 2 MAXIMUM CONTACT RATING CROSS NOMINAL NOMINAL SWITCHING CONTINUOUS RESISPOWER TANCE LOAD CARRY CURRENT HAMLIN (mW) (OHMS) HE- DIP MRRDL1AS8-5D 5 3.8 0.5 750 35 MRRDL1AS8-12D 12 9.0 1.0 1000 145 MRRDL1AS8-24D 24 18.0 2.0 4600 125 W172DIP-141 5 3.8 0.5 200 125 W172DIP-145 12 9.0 1.0 1000 144 W172DIP-146 24 18.0 2.0 2200 180 3.8 0.5 200 125 10VA 0.5AMP 100VDC 1.5 AMPS 7 OPERATE SPDT 14 13 2 1 9 6 8 4VA .25 AMP 100VDC 0.5AMPS 721C0500 JWD-172-155 721C1200 JWD-172-157 721C2400 JWD-172-158 721C0510 JWD-172-159 721C1210 JWD-172-161 721C2410 JWD-172-162 721E0500 - 721E1200 - 721E2400 - 721E0510 - 721E1210 - 721E2410 - 7 SPDT WITH CLAMPING DIODE 14 13 9 8 W172DIP-147 1 + 2 SPDT 14 13 6 9 7 5 W172DIP-149 12 9.0 1.0 1000 144 W172DIP-150 24 18.0 2.0 2200 180 W172DIP-31 5 3.8 0.5 500 125 12 9.0 1.0 1000 290 W172DIP-34 24 18.0 2.0 2200 270 6 7 1 2 SPDT WITH CLAMPING DIODE 14 13 9 8 W172DIP-35 5 3.8 0.5 500 125 + 2 6 0.5AMPS 8 W172DIP-33 1 4VA .25 AMP 100VDC W172DIP-37 12 9.0 1.0 1000 300 W172DIP-38 24 18.0 2.0 2200 270 4VA .25 AMP 100VDC 4VA .25 AMP 100VDC 0.5AMPS 0.5 AMPS 7 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 74 DIP DUAL IN-LINE PACKAGE REED RELAY 171 & 172 (SPDT) COIL Measured @ 25˚C CIRCUIT DIAGRAM TOP VIEW PART NUMBERS MAXIMUM CONTACT RATING NOMINAL NOMINAL NOMINAL SWITCHING CONTINUOUS MAXIMUM MINIMUM RESISPOWER INPUT LOAD CARRY CURRENT PULL-IN DROPOUT TANCE (mW) VOLTAGE (OHMS) CROSS REFERENCE TO HAMLIN HE- POTTER & BRUMFIELD SPDT 14 13 1 2 9 6 8 W172DIP-1 5 3.8 0.5 200 125 W172DIP-3 12 9.0 1.0 500 300 W172DIP-4 24 18.0 2.0 2200 270 W172DIP-5 5 3.8 0.5 200 125 W172DIP-7 12 9.0 1.0 500 300 W172DIP-8 24 18.0 2.0 2200 270 7 4VA .25 AMP 100VDC 0.5 AMPS 721R0500 JWD-172-1 721R1200 JWD-172-3 721R2400 JWD-172-4 721R0510 JWD-172-5 721R1210 JWD-172-7 721R2410 JWD-172-8 SPDT WITH CLAMPING DIODE 14 13 1 + 2 9 6 8 7 4VA .25 AMP 100VDC 0.5 AMPS SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 172DIP (SPDT) PACKAGE STYLE FOR W172 DIPS DPDT COIL Measured @ 25˚C CIRCUIT DIAGRAM TOP VIEW PART NUMBERS MAXIMUM CONTACT RATING NOMINAL NOMINAL NOMINAL SWITCHING CONTINUOUS MAXIMUM MINIMUM RESISPOWER INPUT LOAD CARRY CURRENT PULL-IN DROPOUT TANCE (mW) VOLTAGE (OHMS) DPDT 14 13 1 2 9 6 8 W172DIP-17 5 3.8 0.3 46 540 W172DIP-19 12 9.0 0.3 266 540 W172DIP-20 24 18.0 0.3 1066 540 W172DIP-21 5 3.8 0.3 46 540 W172DIP-23 12 9.0 0.3 266 540 W172DIP-24 24 18.0 0.3 1066 540 10VA 0.5 AMP 100VDC 1.0 AMPS 10VA 0.5 AMP 100VDC 1.0 AMPS 7 DPDT WITH CLAMPING DIODE 14 13 + 1 2 9 6 8 172 DIPS WITH DPDT CONTACT ARRANGEMENTS HAVE A NEW PACKAGE STYLE. NEW PACKAGE SWITCHES HIGHER CURRENT UP TO 0.5 AMP @ 100 VDC 7 SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 172DIP (DPDT) PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION PAGE 75 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 GENERAL SPECIFICATIONS MINIATURE REED RELAYS MINIATURE REED OUTLINE DIMENSIONS 1.15 Max. (29.2) DIMENSIONS SHOWN ARE IN INCHES AND ( MILLIMETERS ) .355 (9.0) .125 (3.2) Typ. 1.00 (25.4) .400 (10.16) SIZE I .050 (1.27) Typ. Slotted holes for Terminal Pins. .075 (1.9) SIZE II .500 (12.7) .100 (2.54) Typ. .900 (22.86) SIZE IV .700 (17.8) SIZE III BOTTOM VIEW ALL SIZES STANDARD PRINTED CIRCUIT RELAY HAS 1.00" X 0.1" GRID SPACING SIZE I RELAY CLASS CONTACT CONFIGURATION: SIZE II CONTACT RATING MAX. (Resistive Load): SWITCHING VOLTAGE MAX. SWITCHING CURRENT MAX. CARRY CURRENT MAX. 101/193 104/193 SPST-NO SPST-NO Latching (SPST-NO) 3PST-NO Latching up to 6PST-NO SPDT, DPDT for 104 Series 10 VA 200DC/130 AC 0.5 AMPS 2 AMPS 4VA 100 VDC 0.5 AMPS 1 AMPS INITIAL CONTACT RESISTANCE ( IN MILLIOHMS ): SPDT,DPDT, 3PDT,4PDT (193 Series) 200 Milliohms Max. INSULATION RESISTANCE (Ohms) TESTED AT 100 VDC: 131 134 SPST-NO or DPST-NO Mercury Mercury (SPDT) Mercury DPDT 50VA 500 VDC 2 AMPS 3 AMPS 50VA 500 VDC 2 AMPS 3 AMPS 100 Milliohms Max. Contact resistance Stability ± 10% over Life. 109 Min. 1010 Min. 1010 Min. 200 VDC 1000 VDC 1000 VDC 500 VDC 1000 VDC 1000 VDC .3pF 2.0 pF 3.0pF .9pF 2.0 pF 2.5pF SIZE III DIELECTRIC STRENGTH: MIN. ACROSS OPEN CONTACTS: MIN. BETWEEN MUTUALLY INSULATED POINTS: CAPACITANCE: ( non-shielded relay) ACROSS OPEN CONTACTS: OPEN CONTACTS TO COIL: CLOSED CONTACTS TO COIL: SIZE IV TEMPERATURE: MAX. AMBIENT OPERATING (˚C ) TEMPERATURE: MIN. AMBIENT OPERATING ( ˚C ) STORAGE TEMPERATURE: MOUNTING POSITION: LIFE AT RATED LOAD: With appropriate Contact protection ( End of life 1 Ohm ) OPERATE TIME: (Typical- in Micro-Sec.]). TYPICAL RELEASE TIME: (in Micro-Sec.) Diode Suppression: No Suppression: PACKAGING: . 3pf Typical Form "A" 2.0 pF Typ. Form "C" 3.0pF Typ. 85 ˚C or ( 120 ˚C -70˚ x [ Coil Power]) whichever is lower - 40˚C - 60˚C to + 105˚C ANY - 37˚C - 40˚C to + 105˚C Vertical ± 15˚ 40 x 108 3 x 108 at low level 50 x 108 5 x 108 at low level 1.0 mS, for N.O. 1.0 mS, for N.C. 2.0 mS, for N.O. 2300 µS 2000 µS 1.0 mS, for N.O. 1.5 mS, for N.C. 1.0 mS for NO 1.5 mS for NC 10 Million Operations 100 Million Operations at Low level 2.0 mS 2.5 mS Dust covered, Epoxy Encapsulated is Standard. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 76 MINIATURE CLASS 101 DRY MINIATURE REED RELAY REED PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NON-STANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. SIZE I Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles. .100 (2.54) Typ. SIZE III COIL MEASURED AT 25˚C CIRCUIT DIAGRAM TOP VIEW CASE SIZE PART NUMBERS MAX. CONTACT RATING NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL MAX. SWITCHING POWER SWITCHING CURRENT & CARRY INPUT PULL-IN DROPOUT RESISTANCE CURRENT (mW) VOLTAGE LOAD VOLTAGE (OHMS) SPST-NO 6 5 I 1 W101MPCX-2 W101MPCX-3 12 24 9.0 18.0 1.0 2.0 1400 3300 102 175 W101MPCX-5 W101MPCX-6 W101MPCX-7 5 12 24 4.0 9.0 18.0 0.5 1.0 2.0 90 430 1500 425/425 2500/2500 10 VA 0.5 AMP 200 VDC 2 AMPS 280 340 380 10 VA 0.5 AMP 200 VDC 2 AMPS 60 60 10 VA 0.5 AMP 200 VDC 2 AMPS 2 3PST-NO 12 11 III 1 2 SPST-NO MAGNETIC LATCH 11 De-Latch (Reset) + 12 W101LMPCX-16 W101LMPCX-17 III Latch (Set) 1 5/5 12/12 3.8 9.0 To Set or Reset - + 2 PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION PAGE 77 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 MINIATURE CLASS 131 MERCURY REED PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NON-STANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. SIZE I Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles. .100 (2.54) Typ. SIZE II SPST-NO MERCURY UP 5 6 W131MPCX-3 W131MPCX-4 1 1 12 24 9.0 18.0 1.0 2.0 330 1400 435 410 50 VA 2.0 AMP 500 VDC 3 AMPS 50 VA 2.0 AMP 500 VDC 3 AMPS 2 DPST-NO MERCURY UP 9 10 W131MPCX-7 W131MPCX-8 II 1 12 24 9.0 18.0 1.0 2.0 230 1200 626 480 2 PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION For Class 131 allow a minimum of 30 seconds after mounting for excess Mercury to clear from the contacts before using. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 78 MINIATURE CLASS 104 DRY MINIATURE REED RELAY REED SIZE I PIN SPACING OF .100" IS STANDARD. PIN SPACING OF .150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles. .100 (2.54) Typ. SIZE III CASE SIZE CIRCUIT DIAGRAM TOP VIEW PART NUMBERS COIL MEASURED AT 25˚C MAX. CONTACT RATING NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL MAX. SWITCHING POWER SWITCHING CURRENT & CARRY INPUT PULL-IN DROPOUT RESISTANCE CURRENT (mW) VOLTAGE LOAD VOLTAGE (OHMS) SPDT 6 5 W104MPCX-3 I 1 24 18.0 2.0 2600 220 4 VA 0.25 AMP 100VDC 0.5 AMPS 9.0 1.0 230 626 4 VA 0.25 AMP 100VDC 0.5 AMPS 4.0 9.0 18.0 0.5 1.0 2.0 45 230 1200 4 VA 0.25 AMP 100VDC 0.5 AMPS 2 DPDT 9 10 II W104MPCX-6 1 12 2 DPDT 7 8 W104MPCX-149 W104MPCX-150 W104MPCX-151 II 1 5 12 24 556 626 480 2 PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION PAGE 79 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 MINIATURE CLASS 134 MERCURY REED SIZE I PIN SPACING OF .100" IS STANDARD. PIN SPACING OF .150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. Spacing between filled in circles in schematics are on a .100 Grid Pattern. Pin omitted on unfilled circles. .100 (2.54) Typ. SIZE II DPDT MERCURY UP 8 7 W134MPCX-7 W134MPCX-8 II 1 5 12 4.0 9.6 0.5 1.0 45 230 560 620 50 VA 1.0 AMP 500 VDC 2.0 AMPS 2 DPDT MERCURY WITH CLAMPING DIODE + UP 8 7 W134MPCX-10 W134MPCX-11 II - 1 5 12 4.0 9.6 1.0 1.0 45 230 560 620 50 VA 1.0 AMP 500 VDC 2.0 AMPS 5 12 24 4.0 9.0 18.0 0.5 1.0 2.0 60 330 1400 417 435 410 50 VA 1.0 AMP 500 VDC 2.0 AMPS 2 SPDT MERCURY 5 UP 6 I 1 W134MPCX-1 W134MPCX-2 W134MPCX-3 2 PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION For Class 134 allow a minimum of 30 seconds after mounting for excess Mercury to clear from the contacts before using. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 80 MINIATURE CLASS 193 DRY MINIATURE REED RELAY REED PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. SIZE I Spacing between filled in circles in schematics are on .100 Grid Patterns. Pin omitted on unfilled circles. .100 (2.54) Typ. SIZE II CIRCUIT DIAGRAM (Top View) CASE SIZE PART NUMBERS COIL MEASURED AT 25˚C MAX. CONTACT RATING NOMINAL NOMINAL MAX. NOMINAL MAXIMUM MINIMUM SWITCHING CARRY POWER SWITCHING CURRENT & INPUT PULL-IN DROPOUT RESISCURRENT TANCE (mW) VOLTAGE VOLTAGE LOAD (OHMS) SPST-N.O. I 1 3 5 2 W193RE1A3-5S 4 4.0 9.0 18.0 0.5 1.0 2.0 500 420 2300 5 4.0 0.5 350 70 W193RE1C3-12G 12 9.0 1.0 420 350 W193RE1C3-24G 24 18.0 2.0 2300 250 W193RE1A3-12G 6 W193RE1A3-24G 5 12 24 50 350 250 10 VA 0.5 AMP 200 VDC 2 AMPS 4 VA 0.5 AMP 100 VDC 1 AMP 10 VA 0.5 AMP 200 VDC 2 AMP 4 VA 0.5 AMP 100 VDC 1 AMP SPDT I 1 3 2 4 5 6 W193RE1C3-5S DPST-N.O. II 5 4.0 0.5 70 360 6 W193RE2A3-12G 8 12 9.0 1.0 280 500 W193RE2A3-24G 24 18.0 2.0 1500 390 5 4.0 0.5 70 360 12 9.0 1.0 280 500 24 18.0 2.0 1500 390 1 3 2 W193RE2A3-6G 4 5 7 DPDT II 1 3 2 W193RE2C3-6G 4 5 6 W193RE2C3-12G 7 8 W193RE2C3-24G PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION PAGE 81 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 MINIATURE CLASS 193 DRY MINIATURE REED RELAY REED PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS. SIZE III Spacing between filled in circles in schematics are on .100 Grid Patterns. Pin omitted on unfilled circles. .100 (2.54) Typ. SIZE IV CIRCUIT DIAGRAM (Top View) CASE SIZE PART NUMBERS MAX. CONTACT RATING COIL MEASURED AT 25˚C NOMINAL NOMINAL MAX. NOMINAL MAXIMUM MINIMUM SWITCHING CARRY POWER SWITCHING CURRENT & INPUT PULL-IN DROPOUT RESISCURRENT TANCE (mW) VOLTAGE VOLTAGE LOAD (OHMS) 3PST-N.O. III 1 3 2 4 5 7 9 6 8 10 W193RE3A3-6G 5 4.0 0.5 50 500 W193RE3A3-12G 12 9.0 1.0 210 690 W193RE3A3-24G 24 18.0 2.0 1150 500 W193RE3C3-6G 5 4.0 0.5 50 500 W193RE3C3-12G 12 9.0 1.0 210 690 W193RE3C3-24G 24 18.0 2.0 1150 500 W193RE4A3-6G 5 4.0 0.5 50 500 W193RE4A3-12G 12 9.0 1.0 210 690 W193RE4A3-24G 24 18.0 2.0 1150 500 10 VA 0.5 AMP 200 VDC 2 AMP 4 VA 0.5 AMP 100 VDC 1 AMP 10 VA 0.5 AMP 200 VDC 2 AMP 4 VA 0.5 AMP 100 VDC 1 AMP 3PDT 1 3 III 5 7 9 2 4 6 8 10 11 12 4PST-N.O. III 1 3 5 7 9 11 2 4 6 8 10 12 4PDT IV 1 2 3 4 5 7 6 8 W193RE4C3-6G 5 4.0 0.5 35 720 9 10 W193RE4C3-12G 12 9.0 1.0 140 1030 11 13 12 W193RE4C3-24G 24 18.0 2.0 770 750 15 14 16 PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 82 SERIES P.C. TERMINAL, MOLDED MINIATURE REED RELAY MR-Y The MR-Y Series epoxy molded miniature reed relay has terminal pins on each end and spaced 1 inch apart. It is available with two grid spacings - 0.1 inch or 0.15 inch. Available contacts range from SPST-NO to DPDT configurations. As an option, Mercury reeds are available in limited contact configurations. Lower power coils are also available in addition to optional diode across the coil and electrostatic shielding. WIRING DIAGRAM Top View + * + + SPST-NO MR30Y1A MR35Y1A + SPST-NC MR30Y1B MR35Y1B * DPST-NO MR30Y2A MR35Y2A + * * DPDT MR30Y2C MR35Y2C SPDT MR30Y1C MR35Y1C OUTLINE DIMENSIONS Dimensions shown are in Inches and (Millimeter) .950 (24.1) .550 (13.9) .400 (10.1) .312 (7.9) .130 (3.3) .010 (.254) .045 Typ. (1.14) .020 Typ. (.508) DIM. "A" SEE CHART DIM. "B" SEE CHART DIMENSION CHART DIM "A" 0.100 0.10 Grid DIM."A" 0.150 0.15 Grid DIM "B" 0.200 0.10 Grid DIM."B" 0.300 0.15 Grid Position Reference .062 R x .032 Deep 1.00 (25.4) PAGE 83 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 SERIES P.C. TERMINAL, MOLDED MINIATURE REED RELAY MR-Y SPECIFICATIONS MR-Y (Not all Data applies to HG Relays) Package Material: Contact Material: Dielectric Strength: Epoxy, molded Rhodium 200 V rms Across Open Contacts 1500 V rms All other points Insulation Resistance: 1000 Megohms Min. Capacitance: 0.4 pF typical coil to contacts Shock Resistance: 50 G's Vibration Resistance: 20 G's to 2000 Hz Operate & Release Time: 2 Milliseconds Max. Life: 10 Million operations at rated load SPST,DPST-NO & NC 100 Million operations no load SPST,DPST-NO & NC 5 Million operations at rated load SPDT, DPDT contacts. 50 Million operations no load, SPDT, DPDT contacts. CONTACT DATA Material - Rhodium on Dry Reeds COIL DATA Power Consumption (mW) - Coil Resistance, Nominal Voltage ± 10% @ 25˚C SPST, DPST SPDT, DPDT VDC OHMS mW mW OHMS 167 5 313 150 80 12 250 450 575 320 24 268 384 2150 1500 Max. VDC Contacts 200 SPST-NO 200 SPST-NC 28 SPDT, DPDT 500 SPST-NO (HG) 200 SPDT, DPDT(HG) Max. mA 500 500 250 2000 1000 VA 10 10 3 50 28 Must operate at 80% of nominal voltage @ 25˚C Low Power Coils available: Single Pole - 25mW Double Pole - 65mW Struthers-Dunn ORDERING CODE Typical Type No. MR30Y 2A RV -12D Series MR30Y- 0.1 grid, end terminal Min. P.C. Reed Relay MR35Y- 0.15 grid, end terminal Min. P.C. Reed Relay Contact Arrangements 1A - SPST-NO 2A - DPST-NO 1B - SPST-NC 1C - SPDT 2C - DPDT Options Electrostatic Shield (see wiring diagrams)- CODE E Low Power Coils (Dry Reeds Only) - CODE R Diode across Coil (Observe Polarity) - CODE V Mercury Reed Contact, position sensitive SPST-NO or SPDT - CODE Z Coil Voltage (DC only) DC: 5, 12, 24 (Add "D") + Polarity must be observed for models with Form "B" contacts or optional Diode. * Terminal for optional Electrostatic Shield. HG Contact relays are position sensitive. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 84 SERIES MRR & RR AXIAL LEAD, SHIELDED REED RELAY The MRR and RR Series Axial lead epoxy molded reed relays have solid wire leads on each end. They are available with two grid spacings - 0.1 inch for the MRR series and 0.2 inch for the RR series. Available contacts - UP TO 12PSTNO for the MRR series, and 1 -4PST-NO or NC for the RR series. The MRR and RR series come with an external Half shield fixed to the body of the relay. WIRING DIAGRAM (Terminal view ) MRR4A, RR4AF MRR3A, RR3A MRR2A, RR2A MRR1A, RR1A RR1B DIMENSIONAL CHART FOR MRR & RR SERIES RELAYS SERIES A MRR1A MRR2A MRR4A RR1A, RR1B RR2A RR4AF B C DIMENSIONS (Inches) D E F G H 1.062 .425 .425 .018 X .030 ± .005 .440 .515 .500 .500 .028 .028 .535 .810 .655 .655 .055 1.875 .670 .840 .875 .500 .035 .035 X .061 .810 1.385 To convert Inch dimensions to Millimeter use 25.4 x Dimension = Millimeters. OUTLINE DIMENSIONS See dimensional chart above F H MRR4A, RR4AF C Max. F H MRR2A, RR2A G B Max. C Max. F H MRR1A, RR1A, RR1B Min. D B Max. G Min. A Typical Lead spacing .115" Typical Lead spacing .115" PAGE 85 G E B Max. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 SERIES AXIAL LEAD, SHIELDED REED RELAY MRR & RR SPECIFICATIONS MRR & RR Contact Material: Ambient Temperature: Dielectric Strength: Insulation Resistance: Capacitance: Shock Resistance: Vibration Resistance: Operate & Release Time: Life: Rhodium - 40˚C to + 85˚C MRR 400 V rms Across open contacts RR 500 V rms Across open contacts 1500 V rms All other points 1000 Megohms Min. 0.4 pF typical coil to contacts 50 G's MRR - 20 G's to 2000 Hz RR - 10 G's to 450 Hz 2 to 10 Milliseconds based on the amount of contacts. 10 Million operations at rated load 200 Million operations no load COIL DATA MRR SERIES Coil Resistance & Nominal Voltage Measured at ± 10% @ 25˚C. SPST-NO DPST-NO 4PST-NO 12PST-NO OHMS OHMS VDC OHMS OHMS 24 72 6 144 288 94 288 12 576 1152 384 1152 24 2300 4600 1536 3300 48 COIL DATA RR SERIES Coil Resistance & Nominal Voltage Measured at ± 10% @ 25˚C. DPST-NO 4PST-NO SPST-NO or NC OHMS OHMS OHMS VDC 24 90 36 6 94 360 145 12 384 1440 580 24 1536 5760 2300 48 Must operate at 80% of nominal voltage @ 25˚C Must operate at 70% of nominal voltage @ 25˚C Options RR only - Preformed leads welded lead extensions. CONTACT DATA RR SERIES Material - Rhodium on Dry Reeds CONTACT DATA MRR SERIES Material - Rhodium on Dry Reeds Contacts 1-4PST-NO Max. VDC 200 Max. mA 500 VA 10 Contacts 1-4PST-NO SPST-NC Max. VDC 250 250 Max. AMPS 1.0 1.0 VA 15 15 NOTE: Voltage, Current, and Power ratings in the tables above are independent maximums and no single value is to be exceeded. Ratings are based on noninductive, straight resistive, AC or DC loads without inrush. Other loads require contact protection and /or de-rating. Struthers-Dunn ORDERING CODE Typical Type No. MRR or RR 2A -12D Series MRR- 0.1" Lead spacing RR- 0.2" Lead spacing Contact Arrangements 1A - SPST-NO 2A - DPST-NO 3A - 3PST-NO 4A - 4PST-NO 1B - SPST-NC (RR series Only) Coil Voltage (DC only) DC: 6, 12, 24, 48 (Add "D") (5 volt and other voltages available) WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 86 series RRN OPEN STYLE, METAL COVER/SHIELD REED RELAY The RRN Series is a open construction, one piece nylon bobbin, P.C. terminal assembly with a metal Cover/Shield (3 sided). * WIRING DIAGRAMS (Top View) RRN1A RRN2A .740 Wide .958 Wide RRN1C RRN1B .740 Wide .958 Wide + RRN3A 1.188 Wide RRN2B 1.188 Wide + RRN4A RRN2C RRN3C 1.418 Wide 1.418 Wide 1.418 Wide OUTLINE DIMENSIONS Shown in Inchs and (Millimeters) * See Wiring Diagrams for Width. 2.50 Max. (63.5) * .64 Max. (16.2) 0.156 (3.9) 1.90 Max. (48.2) .38 (9.6) .200 (5.0) 0.10 (2.54) .800 (20.3) .500 (12.7) 2 POLE CASE SIZE Terminals on 0.2 Inch grid. The 1 and 3 pole units have the middle terminals on the center line. PAGE 87 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 series OPEN STYLE, METAL COVER/SHIELD REED RELAY RRN SPECIFICATIONS RRN Contact Material: Ambient Temperature: Dielectric Strength: Insulation Resistance: Capacitance: Shock Resistance: Vibration Resistance: Operate Time: Release Time: Life: Rhodium - 40˚C to + 85˚C 500 V rms Across open contacts 1500 V rms All other points 1000 Megohms Min. 0.4 pF typical coil to contacts 50 G's RR - 10 G's to 450 Hz 6 Milliseconds max. depending on 6 Milliseconds worst case. 10 Million operations at rated load 200 Million operations no load all 1-4PST-NO & SPST-NC 50 Million Operations at no load for all SPDT, DPDT Contacts. CONTACT DATA Contacts Max. VDC 1-4PST-NO 250 1-2PST-NC 250 SPDT, DPDT 250 COIL DATA Coil Resistance & Nominal Voltage Measured at ± 10% @ 25˚C NOM. VDC 6 12 24 48 1 POLE OHMS 150 600 2400 4000 2 POLE OHMS 100 400 1600 4000 3 POLE OHMS 50 200 800 3000 4 POLE OHMS 40 150 600 2300 Max. Amps 1.0 1.0 0.5 VA 15 15 10 NOTE: Voltage, Current, and Power ratings in the table above are independent maximums and no single value is to be exceeded. Ratings are based on noninductive, straight resistive, AC or DC loads without inrush. Other loads require contact protection or de-rating. Must operate at 80% of nominal voltage @ 25˚C Struthers-Dunn ORDERING CODE Typical Type No. RRN 3A EV -12D Series RRN- Semi open, 3 sided shield Contact Arrangements 1A - SPST-NO 2A - DPST-NO 3A - 3PST-NO 4A - 4PST-NO 1B - SPST-NC 2B -DPST-NC 1C - SPDT 2C - DPDT Options Electrostatic Shield (Consult Factory For Wiring Code E Diode Across Coil (Observe Polarity, Consult Factory) Code V Coil Voltage (DC only) DC: 6, 12, 24, 48 (Add "D") (5 volt and other voltages available) SPECIAL OPTIONS Special Wiring . Magnetic Latch Version . Consult Factory WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 88 CLASS OPEN STYLE, METAL COVER/SHIELD REED RELAY 102 102MPCX/RMPCX SPST-N.O. METAL SHIELD ON THREE SIDES. 0.2 GRID SPACING. OUTLINE DIMENSIONS Dimensions shown are in Inch and (Millimeter) .760 Max. (19.3) 2.67 Max. (16.5) .65 Max. (16.5) 1.90 Max. (48.2) 0.16 (4.0) .38 (9.6) .200 (5.0) .18 Max. (4.5) .400 (10.1) 1 POLE CASE SIZE GENERAL SPECIFICATIONS 102 102 102R RELAY CLASS Contact Resistance Initial: 200 200 Dielectric Withstanding voltage: Across Open Contacts: 700 VDC 450 VDC Between all other mutually Insulated points.: 1000 VDC Operate Time (mS): Bounce Time No Diode (mS): CIRCUIT DIAGRAM (TOP VIEW) 1.0 2 PART NUMBERS 2.0 2 RELAY CLASS Capacitance, Non Shield, N.O.: Insulation Resistance: Coil Dissipation (mW) Mounting Position: Shock (Non operation): Vibration: Temperature Range (operating): Life At rated load: 102 102R 1.0 pf 1.5 pf 109 at 100 VDC 50 to 1.5W 600 Any 30 G's 11mS ± 1 mS 1/2 Sign 10 G"s 10 to 1000 Hz -40˚C to + 85˚C 200 Million 20 Million @1A, 115V rms COIL MEASURED AT 25˚C MAX. CONTACT RATING NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL SWITCHING SWITCHING CARRY RESISINPUT PULL-IN DROPOUT TANCE POWER CURRENT & LOAD CURRENT (mW) VOLTAGE VOLTAGE (OHMS) SPST-N.O. 1 AMP W102MPCX-7 12 9.0 1.0 250 Ω W102MPCX-8 24 18.0 2.0 1000 Ω 12 9.0 1.0 250 Ω 580 mW 15VA 1 AMP 250VDC 2 AMPS 3 AMP 250VDC 3.5 AMPS SPST-N.O. 3 AMP W102RMPCX-2 580 mW W102RMPCX-3 24 18.0 2.0 1000 Ω 100VA PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION PAGE 89 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS 150 WATT, COAXIAL R.F. SWITCHING RELAY 120 120 COAXIAL RELAY PANEL MOUNT WITH RG58C/U CABLE (50 OHM ) SWITCHING UP TO 470 MHz 1.73 (44.0) RG58C/U RG58C/U .312 (7.93) 12.0 (304.8) .120 Dia thru holes (2 mounting holes) .671 (17.0) 12.0 (304.8) 1.106 (29.05) .422 .770 (10.71) (19.5) .250 Typ. (6.35) WIRING DIAGRAM Side View Coil Down .078 (1.98) .850 (21.59) .093 (2.38) 2 1 3 1.28 (32.5) 4 5 GENERAL SPECIFICATIONS CLASS 120 CONTACTS R.F. Load rating: Contact Configuration: Contact Resistance (Initial): VSWR ( Voltage Standing Wave Ratio) Cross Talk: 150 Watts max. up to 470 MHz SPDT (1 Form "C") 50 Milliohms max. 1.25 to 1 max., up to 460 MHz 40 DB min., up to 470 MHz. TIMING Operate Time: Release Time: 15 mS Max. @ Nominal Voltage. 7 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated current carrying parts to ground: Insulation Resistance: 1000 V rms @ Sea level 1000 Megohms min. 500 V TEMPERATURE Rated Operation: -55˚C to +65˚C LIFE EXPECTANCY Mechanical: Electrical: 100,000 Operations @ Rated Load. 5 Million Operations no load MISCELLANEOUS Mounting: Connectors: Cable Type: Panel mount with 2 mount holes. None RG58C/U, 12" long, with stripped wire length of .250" 50 Ohms 3 ozs. 85.0 grams approx. Cable Impedance: Weight: COIL Measured @ 25˚C PART NUMBER CONTACT CONFIGURATION NOMINAL INPUT VOLTAGE NOMINAL RESISTANCE (OHMS) DC OPERATED W120X-14 SPDT 12 VDC 100 PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 90 S E C T I O N 4 4 SOLID STATE RELAYS (SSR) 1.5 TO 75 AMPERES Page 91 Magnecraft Struthers-Dunn SOLID STATE RELAYS RELAY SERIES 230E & 230T 226 231 CLASS 6 (DTX) NEW! L.E.D. L.E.D INDICATES RELAY IS IN THE OPERATE MODE. FEATURES L.E.D. "ON" LAMP 5 OR 12 VDC INPUT AC, TRIAC OUTPUT P.C. MOUNT STYLE. UP TO 7 AMP LOADS 5 OR 12 VDC INPUT AC OUTPUT PHOTO ISOLATED, RANDOM TURN-ON COMPATABLE WITH TTL GATES. MOUNTS ON TO-3 TRANSISTOR HEAT SINKS FOR ADDED CURRENT RATING. OUTPUT DATA TYPE 230E HAS 1.5 AMP LOAD RATING TYPE 230T HAS 3.0 AMP LOAD RATING ZERO VOLTAGE SWITCHING. TYPE 230T HAS BUILT IN HEAT SINK. Q.C. TERMINAL, FLANGE MOUNT STYLE. DC CONTROLLED INPUT, AC TRIAC OUTPUT 5 OR 12 VDC INPUT AC OUTPUT UP TO 4 AMP LOADS. UP TO 10 AMP LOADS ZERO VOLTAGE SWITCHING. FLANGE ALSO SERVES AS THE HEAT SINK. PHOTO ISOLATED, ZERO VOLTAGE SWITCHING. 4000 V rms ISOLATION INPUT TO OUTPUT. INTERNAL RC (SNUBBER) NETWORK OUTPUT CONFIGURATION: SPST-NO SPST-NO SPST-NO SPST-NO SPST-NO MAXIMUN ALLOWABLE OUTPUT VOLTAGE & LOAD: 7 AMPS @ 260 OR 380 VAC 1.5 AMPS @ 140 OR 280VAC 3.0AMPS @ 140 OR 280 VAC 4 AMPS @ 140 OR 280 VAC 10 AMPS @ 140 OR 280 VAC (230E) (230T) OUTPUT DEVICE: MINIMUM LOAD: TRIAC SCR SCR TRIAC 50 MILLIAMPS 25 MILLIAMPS 25MILLIAMPS 50 MILLIAMPS 2500 V rms 2500 V rms INSULATION CHARACTERISTICS DIELECTRIC STRENGTH 2500 V rms 4000 V rms INPUT DATA AC - VOLTAGE: DC - VOLTAGE: MAXIMUM PULL-IN VOLTAGE: MINIMUM DROP-OUT VOLTAGE: INPUT IMPEDANCE: NOT AVAILABLE 5 & 12 VDCVDC 4.0 & 9.3 VDC 2.0 VDC 16 MILLIAMPS MAX. NOT AVAILABLE 3 TO 32 VDC 3 VDC 1 VDC 1500 Ω - 30˚ C to + 80˚ C - 40˚ C to + 100˚ C - 30˚ C to + 80˚ C - 40˚ C to + 100˚ C - 30˚ C to + 80˚ C - 40˚ C to + 120˚ C 16 mS TURN ON 60 mS TURN OFF 1/2 CYCLE 1/2 CYCLE 1/2 CYCLE 1010 Ω TO-3 1010 Ω P.C. 1010 Ω TO-3 1010 Ω PANEL H W L 0.25 X 0.5 X .875 H W L .700 X .860 X .860 .78 X 1.75 X 2.25 NOT AVAILABLE 5 & 12 DC 4.3 & 10.3 VDC) 1.5 VDC 15 MILLIAMPS MAX NOT AVAILABLE 5 & 12 VDCVDC 4.0 & 9.3 VDC 2.0 VDC 15 MILLIAMPS MAX. AMBIENT TEMPERATURE OPERATIONAL: STORAGE: - 40˚ C to + 65˚ C - 30˚ C to + 100˚ C RESPONSE TIME OPERATE MAX.: RELEASE MAX: GENERAL DATA INSULATION RESISTANCE: MOUNTING: DIMENSIONS H W L .780 X .670 X .990 APPROVALS H W C L US PAGE 96 PAGE 94, 95 PAGE 102, 103 PAGE 101 PAGE104 PAGE NUMBER PAGE 97,98 PAGE 99, 100 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 92 SPECIFICATIONS PAGE: Magnecraft Struthers-Dunn SOLID STATE RELAYS & OPTO ISOLATORS RELAY SERIES 6 (DSX) 6 (ASX) DC Input - AC Output AC Input - AC Output L.E.D. "ON" LAMP L.E.D. "ON" LAMP 301T 6 (DDX) DC Input - DC Output Opto-Isolators NEW! L.E.D. L.E.D. INDICATES RELAY IS IN THE OPERATE MODE. FEATURES OPTIONAL SAFETY COVER FOR CLASS 6 AVAILABLE SEE PAGE 88 DC CONTROLLED INPUT, AC CONTROLLED INPUT, AC BACK TO BACK SCR AC BACK TO BACK SCR OUTPUT OUTPUT 2.5 TO 75 AMP LOADS 2.5 TO 75 AMP LOADS PHOTO ISOLATED, ZERO VOLTAGE SWITCHING. PHOTO ISOLATED, ZERO VOLTAGE SWITCHING. 4000 V rms ISOLATION INPUT TO OUTPUT. 4000 V rms ISOLATION INPUTTO OUTPUT. INTERNAL RC (SNUBBER) NETWORK INTERNAL RC (SNUBBER) NETWORK RFI SUPPRESSION. RFI SUPPRESSION. L.E.D. "ON" LAMP DC CONTROLLED INPUT, DC OUTPUT AXIAL LEADS WITH SHRINK TUBE CASE 12, 25 & 40 AMP LOADS AC & DC INPUTS AND OUTPUTS TRANSFORMER HIGH INPUT & OUTPUT ISOLATED, 2500 V rms ISOLATION ISOLATION INPUT TO OUTPUT. TURN ON 10KΩ TURN OFF 100KΩ. RFI SUPPRESSION. IDEAL FOR TRIGGERING SCR'S & TRIACS OR LOW VOLTAGE ON-OFF SWITCH. OUTPUT DATA OUTPUT CONFIGURATION: MAXIMUN ALLOWABLE OUTPUT VOLTAGE & LOAD: SPST-NO SPST-NO SPST-NO SPST-NO 2.5 TO 75 AMPS @ 140 OR 280 VAC 2.5 TO 75 AMPS @ 140 OR 280 VAC 12, 25 & 40 AMPS @ 0 TO 200 VDC 0.2 WATTS 250VAC/VDC SCR SCR TRANSISTOR - 50 MILLIAMPS 50 MILLIAMPS 20 MILLIAMPS - 2500 V rms 1000 V rms 120 VAC 2.0 TO 120 VDC TO 10K Ω 100k Ω - OUTPUT DEVICE: MINIMUM LOAD: INSULATION CHARACTERISTICS DIELECTRIC STRENGTH 4000 V rms 4000 V rms INPUT DATA AC - VOLTAGE: DC - VOLTAGE: MAXIMUM PULL-IN VOLTAGE: MINIMUM DROP-OUT VOLTAGE: INPUT IMPEDANCE: NOT AVAILABLE 3 TO 32 VDC 3 VDC 1 VDC 1500 Ω 90 TO 280 VAC 80 TO 140 VDC 90 VAC/80VDC 10 VAC/10VDC 60K Ω NOT AVAILABLE 3.5 TO 32 VDC 3.5 VDC 1 VDC 1000 Ω - 30˚ C to + 80˚ C - 40˚ C to + 120˚ C - 30˚ C to + 80˚ C - 40˚ C to + 120˚ C - 0˚ C to + 80˚ C - 40˚ C to + 120˚ C - 40˚ C to + 60˚ C 1/2 CYCLE 10 mS 40 mS 100 uSec 1.0 mSec - 1010 Ω PANEL 1010 Ω PANEL 1010 Ω PANEL 109 Ω AXIAL LEADS/SOLDER GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: RESPONSE TIME OPERATE MAX.: RELEASE MAX: INSULATION RESISTANCE: MOUNTING: H DIMENSIONS W L 0.78 X 1.75 X 2.25 APPROVALS C PAGE NUMBER PAGE 93 US PAGE 105 H W L 0.78 X 1.75 X 2.25 C US PAGE 106 H W L 0.78 X 1.75 X 2.25 C H W L 0.45 X .438 X 1.4 US PAGE 107 PAGE 108 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 APPLICATION DATA CLASS SSR INTRODUCTION: LOAD CONSIDERATIONS (cont.) SOLID STATE RELAY (SSR) is a relay with isolated input and output, whose functions are achieved by means of electronic components without the use of moving parts as found in Electromechanical relays. DC LOADS: All loads should be considered inductive and a Diode should be placed across the load to absorb any inductive surge on turnoff. PRINCIPLE OF OPERATION: Solid State Relays are similar to Electromechanical relays, in that both use a control circuit and a separate circuit for switching the load. When voltage is applied to the input of the SSR, the relay is energized by a light emitting diode. The light from the diode is beamed into a light sensitive semiconductor which, in the case of zero voltage crossover relays, conditions the control circuit to turn on the output solid state switch at the next zero voltage crossover. In the case of nonzero voltage crossover relays, the output solid state switch is turned on at the precise voltage occurring at the time. Removal of the input power disables the control circuit and the solid state switch is turned off when the load current passes through the zero point of its cycle. APPLICATIONS: Solid State Relays are specially suitable in many applications. Listed below are some typical applications. Microprocessor-based Controls. Computers and Computer Peripherals. Process control Systems using PLCs Temperature Control Systems. Business Machines Medical Equipment Uninterrupted Power Supplies (UPS). Communication Traffic Signals, etc. The Chart below indicates the areas in which SSR's (Solid State Relays) or EMR (Electromechanical Relays) has better capabilities. (X) Indicates the Better choice. SSR X LAMP LOADS: Incandescent lamp loads, though basically resistive, present some special problems. Because the resistance of a cold tungsten filament is about five to ten percent of the heated value, a large inrush current can occur. The period of the inrush current can range from one half cycle to several cycles., depending on the thermal time constant of the filament. It is essential to verify that this inrush current is within the surge specifications of the SSR. Also check that the lamp rating of the SSR is not exceeded. This is a UL rating based on the inrush of a typical lamp. Because of the unusually low filament resistance at the time of turn-on, a zero voltage turn-on characteristic is particularly desirable with tungsten lamps.. It has been demonstrated that a zero voltage turn-on can extend the life of tungsten lamps by limiting inrush current. CAPACITIVE LOADS: Caution must be used with low impedance capacitive loads to verify that the di/dt capabilities are not exceeded. The di/dt of a discharged capacitive load with out external limiting impedance can approach infinity. Zero voltage turn-on is a particularly valuable means of limiting di/dt with capacitive loads. APPLICATION AND SELECTION CRITERIA FOR SOLID STATE RELAYS: Long Life Temperature Cycling Shock and Vibration Resistant Immunity to False Operation due to Transients Generation of RFI, EMI Multipole Multithrow (SPDT) Size (includes Heat Sink) for Equivalent Load Handling Contact Bounce Arcless Switching Acoustic Noise Zero Voltage Switching Ease Of Diagnosing Malfunction IC Compatibility Immunity to Humidity, Salt Spray & Dirt RESISTIVE LOADS: Loads of constant value resistance are probably the simplest application of SSR's. Proper attention to the steady state current ratings and applied blocking voltage specifications normally will result in trouble-free operation. EMR X X X X X X X X X X X X X X LOAD CONSIDERATIONS A major portion of application problems with SSR's result from operating conditions which specific loads impose upon an SSR. The following types of loads point out the potential problems that can occur with SSR's. MOTORS: Specifically, motors frequently have severe inrush currents during starting and can impose unusual voltages during turnoff. The inrush currents connected to mechanical loads having high starting torque or inertia should be carefully determined to verify that they are within the surge capabilities of the SSR. A current shunt and Oscilloscope should be used to examine the duration of the inrush current. Motor starting may frequently reoccur at short intervals and the affect of repetitive inrush currents on the thermal operating point of an SSR must be considered. Check the motor operating current and locked rotor current versus the SSR motor rating. The possibility of abnormally stalled rotor conditions which draw much higher than normal currents should be considered. An extended stalled rotor condition may require an oversized SSR or fuse protection. The generated EMF of certain motors can require an SSR to have a blocking voltage greater than might be expected from steady state line voltage. The voltage applied to an SSR by a motor circuit during turnoff should be examined with an oscilloscope to verify hat the applied voltages are safely below the specified SSR blocking voltages. Otherwise lock-on or erratic turnoff of the motor may occur. Some motor circuits may require higher than normal blocking voltage, transient limiting devices, or other techniques to control the voltage which must be blocked by an SSR during deceleration or direction reversal. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 94 CLASS SSR APPLICATION DATA TRANSFORMERS PROTECTING THE OUTPUT SWITCH In controlling transformers, the characteristics of the secondary load should be considered because it reflects the effective load on the SSR. Voltage transients from secondary load circuits, similarly, are frequently transformed and can be imposed on the SSR. Transformers present a special problem in that, depending on the state of the transformer flux at the time of turnoff, the transformer may saturate during the first half-cycle of subsequent applied voltage. This saturation can impose a very large current (Commonly ten to one hundred times rated primary current) on the SSR and exceed its half-cycle surge rating. An SSR is a four layer semiconductor having 3 terminals: Cathode, Anode and Gate. Normally it blocks current in both the forward and reverse directions. The SCR is triggered on in the forward direction by a small gate current. The SCR remains on until load current decreases to a value less than necessary to maintain the SCR in the on state. When switching AC, two SSR's are connected in inverse parallel. SSR's having random turn-on may have a better chance of survival than a zero voltage turn-on device for they commonly require the transformer to support only a portion of the first half-cycle of the voltage. On the other hand, a random turn-on device will frequently close at the essentially zero voltage point (start of the half-cycle) and then the SSR must sustain the worst-case saturation current. A zero voltage turn-on device has the advantage that it turns on in a known, predictable mode and will normally immediately demonstrate (dependent on turnoff flux polarity) the worst-case condition. The use of an oscilloscope is recommended to verify that the half-cycle surge capability of the SSR is not exceeded. The severity of the transformer saturation problem varies greatly, dependent on the magnetic material of the transformer, saturated primary impedance, line impedance, etc. Both SCR's and Triacs are members of the thyristor family. Therefore, we use this term to denote both devices. There are 4 ways to put a thyristor into a conducting mode. Only one method is desirable and the other three are the source of most application problems. A safe rule of thumb in applying an SSR to a transformer primary is to select an SSR having a half-cycle current surge rating (RMS) greater than the maximum applied line voltage (RMS) divided by the transformer primary resistance. The primary resistance is usually easily measured and can be relied on as a minimum impedance limiting the first half-cycle of inrush current. The presence of some residual flux plus the saturated reactance of the primary will then further limit, in the worst case, the half-cycle surge safely within the surge rating of the SSR. D. Thermal Turn-on: Allowing the temperature of the thyristor to go beyond the value sufficient to cause excessive leakage current, causing turn-on and possible thermal runaway. A Triac also has 3 terminals, like the SCR, it normally blocks current in both directions; but may be triggered in either direction by a small gate current The 4 methods of Thyristor turn-on are A. Gate Turn-on: By injecting a controlled current into the gate (the desired method). B. Forward Breakover Turn-on: A voltage in excess of the Breakover (or Peak Blocking) voltage across Thyristor. C. DV/DT turn-on: A voltage which rises faster than the Thyristor can tolerate, and still remain in the off state. The last three methods can be protected against as follows. In those situations where high peak voltage transients occur, effective protection can be obtained by using metal oxide varistors (MOV). The MOV is a bidirectional voltage sensitive device that has low impedance when its design voltage threshold is exceeded. HEAT SINKING SELECTING THE PROPER SSR NOMINAL LOAD CURRENT: Initially select a relay whose current rating exceeds the normal load current. Using the load current vs. temperature chart for that relay, check the actual current capacity at the ambient temperature to which the relay will be subjected. As an example, the chart below shows that a 25 ampere relay provided with a suitable heat sink can safely carry a maximum of 17 amperes continuously at 40˚C ambient. Since heat degrades the output semiconductor every effort should be made to keep the operating temperature of the SSR as low as possible 25 Amp Styles Load Current (Amps RMS) 40 Mounted on Heat Sink with 1˚c/w thermal resistance. (Sink to Ambient) 35 30 25 20 15 6" x 6" x 1/8" Aluminum Plate 10 5 Free Air Mounting 0 20 40 60 80 100 Max. Ambient Temperature (˚C) PAGE 95 It is important to select the right size heat sink for your applications. SSR's will typically generate 1.2 watts per amp of load current. The maximum junction temperature of the output device is 115˚C. The total wattage is divided by the thermal resistance to get the temperature difference between the output device junction and the ambient temperature. For example a 25 Amp SSR with a 20 Amp load applied dissipates 24 watts when mounted on a aluminum plate 6" X 6" X 1/8" with thermal grease applied between the SSR base and aluminum plate. This combination produces a output junction temperature rise of 24 watts. 24W times (1˚ c/w relay + 1˚ c/w (heat sink) = a operating temperature of 48˚C. FUSING THE SSR has a I2T rating which is a measure of the amount of energy it can safely handle without damage. The I2T rating of the fuse is a measure of the amount of energy the fuse will pass to the SSR. To protect the SSR, the I2T of the Fuse should be less than that of the SSR. An SSR exposed to a surge greater than its nonrepetitive rating will normally fail as a shorted unit. EXPRESSIONS USED IN SPECIFICATIONS dv dt equals the maximum permissable rate of change of voltage in volts/microseconds V= I= (PF)= f= L= C= R 1 & R2 = Line Voltage Load Current Load Power Factor Line Frequency Inductance in Henrys Capacitance in microfarads Resistance in Ohms WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS SPECIFICATIONS CLASS 226, 230, 231 TERMINALS PINS MATE WITH STANDARD PUSH-ON CONNECTORS. P.C. TERMINAL STYLE ALSO AVAILABLE. SSR FLANGED HEAT SINK STYLE WITH 3/16" SPADE STYLE TERMINALS FOR SOLDER OR Q.C. CONNECTORS P.C. BOARD MOUNTABLE 1.5 AMP RATING 230E 226 P.C. BOARD MOUNTABLE WITH HEAT SINK 3.0AMP RATING 231 230T MOUNTABLE ON STANDARD TO-3 TRANSISTOR HEAT SINK MOUNTABLE ON STANDARD TO-3 TRANSISTOR HEAT SINK R UL Recognized File No. E52197 Maximum Average On-State Power Dissipation (Watts) CLASS 230/231 TYPICAL DERATING CURVES CLASS 230E, 230T, 231D 4.0 AMPERES 3.0 Amp (230T) 6.7˚ c/w HEAT SINK 3.0 2.0 1.5 Amp (230E) 1.0 NO HEAT SINK 0 25 40 55 70 80 OPERATING TEMPERATURE (˚C) 14 12 10 8 6 4 2 0 0 1 2 3 4 5 6 RMS On-State Current (AMPERES) CLASS 226 CURRENT RATINGS 6 5 Thermolloy 4 #6103 Base 14˚C/Watt 3 Integral 2 Heat sink 1 0 Wakefield #6908 6.7˚C/Watt Thermal Joint compound used. 20 30 40 50 Wakefield #401A 2˚C/Watt 60 70 AMBIENT TEMPERATURE (˚C) SURGE CURRENT RATINGS 100 80 60 @25˚C 60 Hz 40 20 10 010 .10 1.0 10 SURGE CURRENT DURATION (SECONDS) RMS ON STATE CURRENT (AMPERES) CURRENT AMPS (AC) 7 CLASS 230/231 PEAK SURGE CURRENT (NON-REPETITIVE) RMS AMPERES OUTPUT CURRENT RATINGS VS AMBIENT TEMPERATURE 400 100 40 1.5 Amp series should not be operated above 1.5 Amps at duty cycle greater than 25% 10 4 1 0.4 TJ = 105˚C 0.1 0 1 2 3 Maximum RMS On-State Voltage WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 96 CLASS 226 MINIATURE SOLID STATE RELAY CLASS 226 RANDOM VOLTAGE TURN ON UP TO 7 AMPS SPST—NO DC INPUTS AC OUTPUTS COMPATIBLE WITH TTL GATES. PRINTED CIRCUIT AND PUSH-ON TERMINAL PIN VERSIONS. UL Recognized File No. E52197 R Dimensions shown in Inch and (Millimeters). 1.50 (38.5) .670 (17.0) INPUT .4.92 (12.5) .155 (3.9) 1.18 (30.2) .200 (5.1) OUTPUT .4.92 (12.5) .755 (19.1) .600 Max (15.2) .300 (7.5) + 5V Supply .050 (38.1) FIG. "A" .156 Dia. (3.8) 2 Places .340 (8.6) .940 (23.4) .600 Max (15.2) Series 226 Schematic typical TTL input Connections TOP VIEW + 5V Supply 226R Standard TTL Gate .990 Typ. (25.1) .062 Dia. (1.6) Typ. all Pins FIG. "B" .050 (1.3) Load Input 5 VDC 15 mA Output 120 or 240 VAC up to 7 Amps R1 MAX. RNS LOAD CURRENT (AMPS) THERMAL DERATING CURVE Y 8 6 4 2 Z 0 10 20 30 40 50 60 70 80 AMBIENT TEMPERATURE (˚C) Y= WITHOUT EXTERNAL HEAT SINK. Z= WITH HEAT SINK HAVING 0 SA= 3.2˚C/W. INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Input Current (Typ.) 5VDC Maximum off State Leakage current ID (RMS) Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w PAGE 97 5 or 12 VDC 5V= 240 Ohms / 12V=820 Ohms Typ. Turn-on 10 mS max., Turn-off 60 mS max. 100V/uSec blocking 4V/uSec commutating 120 VAC or 240 VAC 7 Amperes 10 Ma 0.1 mA @ 25˚C 100 Amperes 18 Amperes 24 Amperes 3.4˚c/w WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS MINIATURE SOLID STATE RELAY 226 SPECIFICATIONS CLASS 226 INPUT CHARACTERISTICS Reverse Polarity Protected: Input Filtered for transients less than one millisecond.: OUTPUT CHARACTERISTICS Rated Load Current: IT (RMS): Line Voltage Range (VAC): Maximum output voltage (VAC): Non-Repetitive Peak Voltage VDSM (Blocking Voltage): Minimum Load Current IT MIN (RMS) to maintain “On”: Maximum Off State Leakage current ID (RMS): Maximum RMS On-State Voltage VT (RMS) Maximum Voltage drop across relay output @ rated current: Minimum off-state dv/dt: MISCELLANEOUS Contact configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance RISO @ 500VDC: Operating temperature Range: Storage temperature Range: Life: Mounting: Weight: NO NO 7 Amps W226R & RE-7 Models: 120 VAC, W226R & RE-8 Models: 240 VAC W226R & RE-7 Models: 260 VAC, W226R & RE-8 Models: 380 VAC W226R & RE-7 Models: 400 VAC, W226R & RE-8 Models: 700 VAC 50 mA 0.1 mA @ 25˚C, 1.0 mA @ 65˚C W226R & RE-7 Models: 1.8V, W226R & RE-8 Models: 3.6 V 100V/uSec blocking 4V/uSec commutating SPST-NO 2500 VAC 1010 Ω -30°C to +80°C -40°C to +100°C Greater than 100 million operations TO-3 0.45 oz. (13 g) PUSH-0N TERMINAL RECEPTACLES MOLEX FOR 18-22 AWG 02-06-1103 FOR 24-30 02-06-1132 WINCHESTER 156-10185 156-10245 INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) PART NUMBERS FIGURE INPUT VOLTAGE MIN. MAX. PULL-IN DROPOUT VOLTAGE VOLTAGE NOMINAL VOLTAGE MAX. VOLTAGE OUTPUT CURRENT 4.3 VDC 10.3 VDC 4.3 VDC 10.3 VDC 1.4 VDC 2.5 VDC 1.4 VDC 2.5 VDC 120 VAC 120 VAC 240 VAC 240 VAC 260 VAC 260 VAC 380 VAC 380 VAC 7 AMPS 7 AMPS 7 AMPS 7 AMPS 4.3 VDC 10.3 VDC 4.3 VDC 10.3 VDC 1.4 VDC 2.5 VDC 1.4 VDC 2.5 VDC 120 VAC 120 VAC 240 VAC 240 VAC 260 VAC 260 VAC 380 VAC 380 VAC 7AMPS 7AMPS 7 AMPS 7AMPS PUSH ON TERMINALS W226R-7-5A1 W226R-7-12A1 W226R-8-5A1 W226R-8-12A1 A A A A 5 VDC 12 VDC 5 VDC 12 VDC PRINTED CIRCUIT TERMINALS W226RE-7-5A1 W226RE-7-12A1 W226RE-8-5A1 W226RE-8-12A1 B B B B 5 VDC 12 VDC 5 VDC 12 VDC All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru Stocking Distribution. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 98 CLASS MINIATURE P.C. SOLID STATE RELAY 230 CLASS 230 1.5 & 3 AMP SWITCHING SPST—NO DC INPUTS, AC OUTPUTS ZERO VOLTAGE SWITCHING. CLASS 230 E 1.5 AMP RATED Dimensions Shown in Inches & (Millimeter) 0.296 0.875 (7.5) (22.3) 0.50 (12.7) 230E 10 .020 (.50) 0.20 (5.1) 0.6 (15.2) 0.30 (7.6) +16 Bottom -1 8 0.30 0.50 (7.62) (12.7) 0.7 (17.7) CLASS 230T 4.0 AMP RATED FIGURE A .030 (.76) 0.335 (8.5) 230T 1.23 (31.4) 10 +16 DC AC Input Output 8 Bottom -1 .200 (5.1) .400 (10.1) 0.150 Dia. (3.8) FIGURE B UL Recognized File No. E52197 INPUT CHARACTERISTICS Input Impedance (Current @ Nominal Voltage) Response Time Maximum Rate of Rise of Off State Voltage dv/dt OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Maxium off State Leakage current ID (RMS) Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w PAGE 99 Terminals .025, (6.3) Typical R PIN 16 = + DC INPUT PIN 1 = DC INPUT PIN 8 = AC LOAD OUTPUT PIN 10 = AC LOAD OUTPUT 5 or 12 VDC 13mA typical / 16 mA max. 1/2 Cycle 200V/uSec blocking 4V/uSec commutating 120 VAC or 240 VAC 230E 1.5 Amps, 230T 3.0 Amps 1 mA max. 20 Amperes 5 Amperes 4.5 Amperes 230T 8˚c/w WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS MINIATURE P.C. SOLID STATE RELAY 230 SPECIFICATIONS CLASS 230 INPUT CHARACTERISTICS Reverse Polarity Protected: Input Filtered for transients less than one millisecond.: OUTPUT CHARACTERISTICS Rated Load Current: IT (RMS): Line Voltage Range (VAC): Maximum output voltage (VAC): Non-Repetitive Peak Voltage VDSM (Blocking Voltage): Minimum Load Current IT MIN (RMS) to maintain “On”: Maximum Off State Leakage current ID (RMS): Maximum RMS On-State Voltage VT (RMS) @ rated current: Maximum rate of rise off-state voltage dv/dt: MISCELLANEOUS Contact configuration: Dielectric Strength VISO (Input-Output Isolation): Insulation Resistance RISO @ 500VDC: Operating temperature Range: Storage temperature Range: Life: Mounting Weight: NO NO W230E Models: 1.5 Amps, W230T Models: 3 Amps 120 VAC or 240 VAC 140 VAC or 280 VAC 120V Models: 400 VAC, 240V Models: 500 VAC 20 mA @ 25˚C 1.0 mA max. 1.7 V 200V/uSec SPST-NO 2500 VAC 1010 Ω -30°C to +80°C -40°C to +100°C Greater than 100 million operations P.C. 0.37 oz. (10.6 g) PUSH-0N TERMINAL RECEPTACLES MOLEX FOR 18-22 AWG 02-06-1103 FOR 24-30 02-06-1132 WINCHESTER 156-10185 156-10245 INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE PART NUMBERS FIGURE INPUT VOLTAGE MIN. MAX. PULL-IN DROPOUT VOLTAGE VOLTAGE NOMINAL VOLTAGE MAX. VOLTAGE OUTPUT CURRENT CP CLARE/ THETA-J 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 120 VAC 240 VAC 120 VAC 240 VAC 140 VAC 280 VAC 140 VAC 280 VAC 1.5 AMPS 1.5 AMPS 1.5 AMPS 1.5 AMPS 0FA1202 0FA2402 0FB1202 0FB2402 120 VAC 240 VAC 120 VAC 240 VAC 140 VAC 280 VAC 140 VAC 280VAC 3 AMPS 3 AMPS 3 AMPS 3 AMPS PRINTED CIRCUIT TERMINALS W230E-1-5 W230E-2-5 W230E-1-12 W230E-2-12 A A A A 5 VDC 5 VDC 12 VDC 12 VDC 4.0 VDC 4.0 VDC 9.3 VDC 9.3 VDC PRINTED CIRCUIT TERMINALS WITH HEAT SINK W230T-3-5 W230T-4-5 W230T-3-12 W230T-4-12 B B B B 5 VDC 5 VDC 12 VDC 12 VDC 4.0 VDC 4.0 VDC 9.3 VDC 9.3 VDC 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 0FA1205D 0FA2405D 0FB1205D 0FB2405D All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru Stocking Distribution. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 100 CLASS 231 MINIATURE SOLID STATE RELAY CLASS 231 4 AMPS SPST—NO DC INPUTS, AC OUTPUTS ZERO VOLTAGE SWITCHING. .340 Max (8.6) .600 Max (15.24) ,048 Max (1.2) 1.40 (35.5) 1.19 (30.2) + 3 INPUT LOAD 1 AC .860 (21.8) Top View 2 AC .078 R (1.98) .250 (6.3) .250 x .032 Typ. (6.3) x .81 - 4 .595 (15.1) .860 (21.8) .187 x .032 Typ. (4.7) x .81 Dimensions Shown in Inches & (Millimeters) UL Recognized File No. E52197 INPUT CHARACTERISTICS 5 or 12 VDC Input Impedance (Current @ Nominal Voltage) Response Time Maximum Rate of Rise of Off State Voltage dv/dt 13mA typical / 16 mA max. 1/2 Cycle 200V/uSec blocking 10V/uSec commutating 120 VAC or 240 VAC OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) Maximum off State Leakage current ID (RMS) Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w 4 Amperes 1 mA @ 25˚C 20 Amperes 5 Amperes 4.5 Amperes 6˚c/w THE W231 SSR HAS THE SAME ELECTRICAL SPECIFICATIONS AS LISTED FOR THE W230 SSR's. THE EXCEPTION IS THE CLASS W231 IS RATED AT 4.0 AMPS. QUICK DISCONNECT TERMINALS WITH .060 DIA. HOLES TERMINALS 1 & 2, .250 X .032 BRASS TERMINALS 3 & 4, .187 X .032 BRASS INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE PART NUMBERS INPUT VOLTAGE MIN. MAX. PULL-IN DROPOUT VOLTAGE VOLTAGE NOMINAL VOLTAGE MAX. VOLTAGE OUTPUT CURRENT 2.0 VDC 2.0 VDC 2.0 VDC 2.0 VDC 120 VAC 240 VAC 120 VAC 240 VAC 140 VAC 280 VAC 140 VAC 280 VAC 4 AMPS 4 AMPS 4 AMPS 4 AMPS CP CLARE/ THETA-J FLANGE MOUNT W231D-3-5 W231D-4-5 W231D-3-12 W231D-4-12 5 VDC 5 VDC 12 VDC 12 VDC 4.0 VDC 4.0 VDC 9.3 VDC 9.3 VDC 0FA1205 0FA2405 0FB1205 0FB2405 All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Mounting: TO-3 Style. Weight: .57oz. (16.2 grams). Part Numbers shown also available thru Stocking Distribution. PAGE 101 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS SPECIFICATIONS SOLID STATE RELAY Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. UL Recognized File No. E52197 NEW! HI DV GH RA /DT TI NG L.E.D. "ON" LAMP UT S INP MINAL R TE CL AS S6 Dimensions shown in Inch and (Millimeter). 2.25 (57.2) 1.87 (47.5) RU CO GG NS ED TR UC T IO N 1.75 (44.45) INPUT T S PU NAL T I OU RM TE 0.32 (8.1) 4 OUTPUT 3 2 INPUT RED L.E.D. 1 1.00 1.75 (25.4) (44.5) SS R OUTLINE DIMENSIONS 0.19 0.37 (4.8) (9.4) 6 1.10 (27.9) .49 Typ. (12.5) .175 Dia. (4.44) (2 Holes) Clamping Plate 4 Places (Not used on models .996 high) .215 (5.46) .265 max. (6.73) OUTPUT SEE CHART INPUT & OUTPUT SCREW SIZE (Shown in Millimeters) UP TO 40 AMP INPUT 3.5 mm ABOVE 40 AMP 3.5 mm .996 max. (25.3) for 25 & 40 amp DDX models & for 75 Amp DSX & ASX models. .800 max (20.32) for models ASX, DSX & DTX models up to 40 Amps & DDX 12 Amp models. OUTPUT 4 mm 6 mm SURGE: OUTPUT 120 & 240 VAC CLASS 6 TYPICAL INPUT CURRENT Input Current (mA) 35 30 25 20 DC INPUT 15 10 AC INPUT 5 0 10 20 30 100 200 300 Input Voltage (Volts) DC Input Models AC Input Models Non- Repetitive Surge RMS Amps 1000 40 500 200 50 75 Amps 40 Amps 25 Amps 20 10 Amps 100 10 5 2.5 Amps 2 1 .01 .02 .05 0.1 0.2 0.5 1.0 2.0 5.0 10.0 Time in Seconds Surge: Curves represent relay tolerance to load surge currents as to magnitude and duration of both repetitive and non-repetitive surge currents. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 102 CLASS GENERAL SPECIFICATIONS 6 SPECIFICATIONS CLASS 6 SOLID STATE RELAYS INPUT CHARACTERISTICS Input voltage range: Power indicator: Reverse Polarity Protected: Input Filtered for transients less than one millisecond.: Control current: OUTPUT CHARACTERISTICS Contact rating: Line Voltage Range (VAC) Maximum output voltage (VAC): Non-Repetitive Peak Voltage VDSM (Blocking Voltage) Minimum Load Current IT MIN (RMS) to maintain “On” Maximum Off State Leakage current ID (RMS) Maximum RMS On-State Voltage VT (RMS) Maximum Voltage drop across relay output @ rated current: Minimum off-state dv/dt: MISCELLANEOUS CHARACTERISTICS Contact configuration: Dielectric Strength VISO (Input-Output Isolation) Insulation Resistance RISO @ 500VDC Operating temperature Range Storage temperature Range Life: Weight 3-32 VDC, 90-280 VAC or 0 to 200VDC L.E.D. Lamp YES: DC Input with AC output styles only. No 12 mA @ 5Vdc, 10 mA @ 120 Vac 2 Amps to 75 Amps W61 Models: 24-120VAC, W62 Models: 40-240 VAC W61: 140VAC, W62: 280 VAC W61: 300VAC , W62: 600VAC Up to 40 amp Models: 50 ma, 50 to 75 Amp models: 250mA Up to 40 amp Models: 8 mA, 50 to 75 Amp models: 10mA Up to 40 amp Models: 1.6V, 50 to 75 Amp models: 1.8 V 500v/usec SPST-NO (1 FORM A) 4000 VAC, DDX models 2500 VAC 1010 Ω -40°C to +80°C -40°C to +100°C Greater than 100 million operations 2.5 to 50 AMP Models: 4 oz. (110 g) 75 AMP Models: 6.8 oz. (192 g) 25 AMP & 40 AMP, DDX Models: 4.76 oz. (135 g) Thermal Derating Curve & Load Characteristics 3 2 Free Air Mounting 0 20 40 60 80 100 Max. Ambient Temperature (˚C) 6" x 6" x 1/8" Aluminum Plate 14 12 Heat Sink with 1˚c/w thermal resistance. 10 8 6 4 25 Amp Styles 40 Load Current (Amps RMS) 6" x 6" x 1/8" Aluminum Plate 1 10 Amp Styles 16 Load Current (Amps RMS) Load Current (Amps RMS) 2.5 Amp Style Free Air Mounting 2 35 30 Mounted on Heat Sink with 1˚c/w thermal resistance. (Sink to Ambient) 25 20 15 10 5 6" x 6" x 1/8" Aluminum Plate Free Air Mounting 0 20 40 60 80 100 Max. Ambient Temperature (˚C) 0 20 40 60 80 100 Max. Ambient Temperature (˚C) 80 -90 Mounted on Heat Sink with 1˚c/w thermal resistance. 70 50 6" x 6" x 1/8" Aluminum Plate 40 30 20 10 Free Air Mounting 0 20 40 60 80 100 Max. Ambient Temperature (˚C) Load Current (Amps RMS) Load Current (Amps RMS) 90 60 6" x 6" x 1/8" Aluminum Plate 45 -95 -100 40 30 -105 20 -110 10 0 0 10 20 30 40 50 60 70 80 Max. Ambient Temperature (˚C) Max. Allowable Case temperature (˚c) 75 Amp Styles 75 40 & 50 Amp Styles All current ratings in the following pages are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). PAGE 103 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS DC CONTROLLED INPUT TRIAC OUTPUT SSR High Transient Capability—Single output features back to back SCR’s and internally mounted RC (snubber) network for high dv/dt applications. Photo-Isolated, Zero Voltage Switching— Optically coupled for 4000 VAC isolation between input and output and RFI suppression. 6 CLASS 6 DC CONTROLLED INPUT WITH L.E.D. "ON" LAMP. AC TRIAC OUTPUT. NEW! L.E.D. "ON" LAMP UL Recognized File No. E52197 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. 3 to 32 VDC INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt 1500 ohms minimum 1/2 Cycle Max. 200 Volts per microsecond 120 or 240 VAC OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) U/L Incandescent Lamp Ampere Ratings U/L Motor Load Ampere Ratings Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w 10.0 7.0 4.5 100 24 42 2.1 SEE CLASS 6 GENERAL SPECIFICATIONS PART NUMBERS INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE TO: NOMINAL MAX. MAX. POTTER & VOLTAGE VOLTAGE CURRENT CRYDOM IDEC BRUMFIELD RANGE RATING MIN. CONTROL MAX. VOLTAGE PULL-IN DROPOUT RANGE VOLTAGE VOLTAGE W6110DTX-1 3-32 VDC 3 VDC 1 VDC 24-120AC 140 VAC 10 AMPS TD1210 - SSRT120D10 W6210DTX-1 3-32 VDC 3 VDC 1 VDC 48-240AC 280 VAC 10 AMPS TD2410 - SSRT240D10 All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru stocking distribution. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 104 CLASS DC CONTROLLED SOLID STATE RELAY 6 CLASS 6 High Transient Capability—Single output features back to back SCR’s an internal mounted RC (snubber) network for high dv/dt applications. Photo-Isolated, Zero Voltage Switching— Optically coupled for 4000 VAC isolation between input, output and RFI suppression. DC CONTROLLED INPUT WITH L.E.D. "ON" LAMP. AC SCR OUTPUTS UP TO 75 AMPS. NEW! L.E.D. "ON" LAMP Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. UL Recognized File No. E52197 INPUT CHARACTERISTICS 3 to 32 VDC Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt 200 400 ohms @ 3 VDC Typical 1/2 Cycle Max. 500 Volts per microsecond 120 VAC or 240 VAC OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) U/L Incandescent Lamp Ampere Ratings U/L Motor Load Ampere Ratings Non-Repetitive Surge Current one Cycle (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w Minimum Load current, (mA). 2.5 2.0 1.0 100 5 72 8.5 50 10 8.0 4.5 100 24 72 1.78 50 25 16 8 250 40 800 1.02 120 40 30 14 350 80 1250 0.63 250 50 30 14 350 100 1250 0.63 250 75 39 25 1150 150 5000 0.63 250 SEE CLASS 6 GENERAL SPECIFICATIONS INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) PART NUMBERS MIN. CONTROL MAX. VOLTAGE PULL-IN DROPOUT RANGE VOLTAGE VOLTAGE NOMINAL VOLTAGE RANGE MAX. VOLTAGE NAX. CURRENT RATING CROSS REFERENCE TO: CRYDOM IDEC POTTER & BRUMFIELD W6102DSX-1 W6110DSX-1 W6125DSX-1 W6140DSX-1 W6150DSX-1 W6175DSX-1 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 24-120AC 24-120AC 24-120AC 24-120AC 24-120AC 24-120AC 140 VAC 140 VAC 140 VAC 140 VAC 140VAC 140VAC 2.5 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS D1202 D1210 D1225 D1240 EOM1DA22-4-32 RSSD-10A EOM1DA42-4-32 RSSD-25A SSR240D25 RSSD-40A RSSD-50A SSR240D50 RSSD-75A SSR240D80 W6202DSX-1 W6210DSX-1 W6225DSX-1 W6240DSX-1 W6250DSX-1 W6275DSX-1 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3-32 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 3 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 1 VDC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 280 VAC 2.5 AMPS 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS D2402 D2410 D2425 D2440 D2450 D2475 RSSD-10A EOM1DA44-4-32 RSSD-25A SSR240D25 RSSD-40A RSSD-50A SSR240D50 RSSD-75A SSR240D80 All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). Part Numbers shown also available thru stocking distribution. PAGE 105 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS AC CONTROLLED SOLID STATE RELAY High Transient Capability—Single output features back to back SCR’s and internally mounted RC (snubber) network for high dv/dt applications. Photo-Isolated, Zero Voltage Switching— Optically coupled for 4000 VAC isolation between input and output and RFI suppression. 6 CLASS 6 AC CONTROLLED INPUT WITH L.E.D. "ON LAMP" AC SCR OUTPUT. NEW! L.E.D. "ON" LAMP UL Recognized File No. E52197 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. INPUT CHARACTERISTICS Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt 90 to 280 VAC or 80 to 140 VDC 13K ohms @ 120VAC typical 10 mS Turn ON, 40 mS Turn OFF. 200 500 Volts per microsecond 120 VAC or 240 VAC OUTPUT CHARACTERISTICS Rated Load Current (Amps rms) U/L Incandescent Lamp Ampere Ratings U/L Motor Load Ampere Ratings Non-Repetitive Surge Current one Cycle surge (Amps peak) Maximum rms Overload current for 1 second Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w Minimum Load current, (mA): 2.5 2.0 1.0 100 5 72 8.5 50 10 8.0 4.5 100 24 72 1.48 50 25 16 8.0 250 40 800 1.02 120 40 50 30 30 14 14 350 350 80 100 1250 1250 0.63 0.63 120 120 75 39 25 1150 150 5000 0.63 120 SEE CLASS 6 GENERAL SPECIFICATIONS INPUT (Over Operating Temperature Range) PART NUMBERS CONTROL VOLTAGE RANGE MAX. PULL-IN VOLTAGE 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE TO: MIN. DROPOUT VOLTAGE NOMINAL MAX. MAX. VOLTAGE VOLTAGE CURRENT CRYDOM RANGE RATING IDEC POTTER & BRUMFIELD W6110ASX-1 W6125ASX-1 W6140ASX-1 W6150ASX-1 W6175ASX-1 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 24-120AC 24-120AC 24-120AC 24-120AC 24-120AC 140 VAC 140 VAC 140 VAC 140 VAC 140VAC 10 AMPS 25 AMPS 40 AMPS 50 AMPS 75 AMPS A1210 A1225 A1240 A1250 A1275 RSSAN-10A RSSAN-25A RSSAN-40A RSSAN-50A RSSAN-75A SSR240A25 SSR240A50 SSR240A80 W6202ASX-1 W6210ASX-1 W6225ASX-1 W6240ASX-1 W6250ASX-1 W6275ASX-1 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 -280 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 90 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 10 VAC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC 48-240AC 280 VAC 2.5 AMPS 280 VAC 10 AMPS 280 VAC 25 AMPS 280 VAC 40 AMPS 280 VAC 50 AMPS 280 VAC 75 AMPS A2402 A2410 A2425 A2440 A2450 A2475 RSSAN-10A RSSAN-25A RSSAN-40A RSSAN-50A RSSAN-75A SSR240A25 SSR240A50 SSR240A80 Part Numbers shown also available thru stocking distribution. All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 106 CLASS DC CONTROLLED INPUT DC OUTPUT 6 CLASS 6 Transformer-Isolated, for 2500 VAC isolation between input and output and RFI suppression. DC CONTROLLED INPUT DC OUTPUT NEW! L.E.D. "ON" LAMP UL Recognized File No. E52197 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. INPUT CHARACTERISTICS 3.5 to 32 VDC Input Impedance Response Time Maximum Rate of Rise of Off State Voltage dv/dt 1000 ohms minimum 100 uS: On, 1.0 mS: Off 600 uS: On, 2.6 mS Off 200 Volts per microsecond 0 OUTPUT CHARACTERISTICS to 200 VDC 12.0 20 mA 27 17 2.83 2.1 1.06 12 mA Rated Load Current (Amps rms) Minimum Load current to maintain "On" Non-Repetitive Surge Current (1 cycle surge) FW rectified current repetitive 60 Hz Amps peak Voltage drop across output @ rated current Max I2T For Fusing ( t= 8-3ms) A2 sec Thermal Resistance Junction To Case 0c/w Max. off state leakage current: 25 20 mA 50 2.83 2.1 1.06 12 mA 40 20 mA 90 2.83 2.1 1.06 12 mA SEE COMPLETE SPECIFICATIONS PAGES 83 & 84 PART NUMBERS INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) MAX. MIN. NOMINAL MAX. PULL-IN DROPOUT VOLTAGE CURRENT VOLTAGE VOLTAGE RANGE RATING CONTROL VOLTAGE RANGE CROSS REFERENCE CRYDOM W6212DDX-1 3.5 - 32 VDC 3.5 VDC 1 VDC 0 -200 VDC 12 AMPS D2D12 W6225DDX-1 3.5 - 32 VDC 3.5 VDC 1 VDC 0 -200 VDC 25 AMPS D1D20* W6240DDX-1 3.5 - 32 VDC 3.5 VDC 1 VDC 0 -200 VDC 40 AMPS D1D40* Part Numbers shown also available thru stocking distribution. All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting surface of suitable heat sink). * Crydom relays only rated at 0 - 100 VDC. PAGE 107 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CLASS 301T OPTO-ISOLATOR OPTICAL COUPLING PROVIDES HIGH INPUT TO OUTPUT ISOLATION. CAN BE USED AS AN ON/OFF SWITCH OR LOW VOLTAGE CONTROLLED RESISTOR. IDEAL FOR TRIGGERING SCR'S AND TRIACS. SSR 301T OPTO-ISOLATOR 0.2 WATT OUTPUT VAC OR VDC OUTPUTS SPECIFICATIONS 301T OUTLINE DIMENSIONS CONTACTS Output Voltage Max:. ± 250 VDC or VAC Peak INSULATION RESISTANCE Dielectric Strength Across Open Contacts: Insulation Resistance: 1000 V rms Between all insulated Points 9 10 Ohms L Shrink Tube Case 0.04 oz (1.1 g) + If DC L INPUT W301T1-2A1 W301T1-2B1 W301T1-12B1 W301T1-120A1 .45 Max (11.4) SCHEMATIC VOLTAGE OUTPUT CURRENT ON (mA) RESISTANCE (Ohms max.) 40 25 24 1.3 1.7 VDC LED 2.0 VDC LED INCAND. 12 VDC/AC 120 VDC/AC NEON PC Lamp UL Recognized File No. E104675 R LAMP TYPE 1.00 ± .125 (25.4 ± 3.17) # 26 AWG Typical NOT RECOMENDED FOR WAVE OR DIP SOLDERING. ALSO MAY BE AFFECTED BY CLEANING SOLVENTS PART NUMBERS 1.40 Max. (35.6) 1.00 ± .125 (25.4 ± 3.17) ENVIRONMENTAL CAPABILITIES Ambient Temperature Operating: -40˚C to + 60˚C Miscellaneous Weight: .438 (11.1) PC 2000Ω 1000Ω 400Ω 1200Ω RESPONSE TIME POWER DISSIPATION Per pole (mW) TURN-ON TO 10KΩ (mS max.) TURN-OFF TO 100KΩ (mS max.) 200 200 200 200 10 5 150 35 50 100 300 100 Add 47KΩ Ohm external series resistor to limit current. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. OUTLINE DIMENSIONS 1.04 Max (26.5) .812 (20.6) 1.93 Max. (49.2) 2.45 (62.3) 2.65 (67.4) EMBOSSED SAFETY COVER CLEAR COVER FOR CLASS 6 SOLID STATE RELAYS PREVENTS ELECTRICAL SHOCK HAZARDS FROM EXPOSED TERMINALS. PART NUMBER 15-700 Weight:: 0.476 oz. (13.5 g) NOT SUPPLIED WITH RELAY. TO BE ORDERED SEPARATELY IF REQUIRED. WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 PAGE 108 S E C T I O N 5 5 TIME DELAY RELAYS AND SENSORS 5 TO 13 AMPERES Page 109 Magnecraft Struthers-Dunn TIME DELAY RELAYS 211 RELAY CLASS/SERIES FEATURES 8 or 11 PIN OCTAL PLUG-IN. CONTACT RESISTANCE: INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: 222 MINIATURE PLUG-IN 8 PIN OCTAL PLUG-IN "ON DELAY" REPEAT CYCLE ON & OFF DELAY 4 PROGRAMMABLE FUNCTIONS REPEATABILITY ±0.1% 62 PROGRAMMABLE TIMING RANGES FIELD ADJUSTABLE BY KNOB 4 INPUT VOLTAGE RANGES INTERVAL, FLASHER, ONE SHOT OR ON & OFF DELAY AVAILABLE REPEATABILITY ±0.1% DPDT DPDT DPDT DPDT 10 AMPS @ 120 VAC, 30VDC 10 AMPS @ 120 VAC, 30VDC 5AMPS @ 120 VAC, 28 VDC 10 AMPS, 120VAC, 28 VDC CONTACT CONFIGURATION: CONTACT MATERIAL 8 or 11 PIN OCTAL PLUG-IN. 67 "ON DELAY" OR OFF DELAY" CONTACT DATA CONTACT RATING: 211 PROG FIELD ADJUSTABLE BY KNOB & DIP SWITCH REPEATABILITY ± 2% FIELD ADJUSTABLE BY SCREW DRIVER 4 POLE STYLES AVAILABLE ±0.1 % REPEATABILITY FIELD ADJUSTABLE TIMING USING KNOBS. P.C. TERMINALS AVAILABLE.. Silver Cadmium Oxide Silver Cadmium Oxide Silver, Gold Overlay Silver cadimum Oxide 50 MILLIOHMS Max. Initial 50 MILLIOHMS Max. Initial 50 Milliohms Max. Initial 50 MILLIOHMS Max Initial 1500 V rms 1500 V rms 1250 V rms 1500 V rms 120 VAC 24 VDC AC - 90 to 130 DC - 20 to 32 120/24 VAC 24 VDC AC - 90 to 130 DC - 20 to 32 DC - 10 to 14, 20 to 32 DC MODELS ONLY DC MODELS ONLY DC MODELS ONLY - 30˚ C to + 55˚ C - 55˚ C to + 85˚ C - 30˚ C to + 55˚ C - 55˚ C to + 85˚ C - 30˚ C to + 80˚ C - 40˚ C to + 100˚ C - 30˚ C to + 55˚ C - 55˚ C to + 85˚ C 0.1 Seconds to 120 Minutes 0.1 Seconds to 15 Minutes AS SELECTED AS SELECTED 0.1 to 30 Seconds - 0.1 Second to 30 Minutes 0.1 Second to 30 Minutes 200,000 Operations 50,000,000 Operations 200,000 Operations 50,000,000 Operations 50,000 Operations 50,000,000 Operations 200,000 Operations 50,000,000 Operations H W L 1.18 X .734 X 1.37 H W L .1.75 X 2.37 X 3.49 COIL DATA AC - VOLTAGE: DC - VOLTAGE: INPUT VOLTAGE RANGE REVERSE POLARITY PROTECTION: AC On Special Order 12 & 24 VDC 120 VAC DC - SPECIAL ORDER 90 to 130 VAC DC MODELS ONLY GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE MAX.: RELEASE MAX: LIFE ELECTRICAL @ rated Load: MECHANICAL: DIMENSIONS H W L 1.75 X 2..37 X 3.5" H W L 1.75 X 2..37 X 3.5" APPROVALS APPLICATION DATA: PAGE NUMBER PAGE 113, 114 PAGE 115, 116 PAGE 117 PAGE 118 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 119 PAGE 110 Magnecraft Struthers-Dunn TIME DELAY RELAYS 388 SHORT BODY 388 KNOB ADJUSTMENT SQUARE BASE PLUG-IN SQUARE BASE PLUG-IN OR FLANGE MOUNT ON DELAY OR OFF DELAY ON DELAY OR OFF DELAY ±0.1 % REPEATABILITY ±3 % REPEATABILITY FIELD ADJUSTABLE TIMING USING KNOB. FIELD ADJUSTABLE TIMING USING EXTERNAL RESISTOR INTERVAL, FLASHER, ONE SHOT OR ON & OFF DELAY AVAILABLE 286/287 388 TRUE OFF DELAY 326/327 SQUARE BASE PLUG-IN RETANGULAR PLUG-IN 8 or 11 PIN OCTAL PLUG-IN. OFF DELAY 286 -ON DELAY, 287 0FF DELAY "ON DELAY" OR OFF DELAY" ±3 % REPEATABILITY FIELD ADJUSTABLE TIMING USING KNOB. POWER TO INPUT NOT REQUIRED DURING TIMING CYCLE. ±3 % REPEATABILITY TIMING FIELD ADJUSTABLE BY KNOB OR EXTERNAL RESISTOR. 1, 2 & 3 POLE 10 AMP SWITCHING. ± 3% REPEATABILITY FIELD ADJUSTABLE BY KNOB OR EXTERNAL RESISTOR. 1, 2 & 3 POLE 10 AMP SWITCHING. DPDT DPDT DPDT SPDT, DPDT, 3PDT SPDT, DPDT, 3PDT 12 AMPS, 120VAC, 28 VDC 12 AMPS, 120VAC, 28 VDC 12 AMPS @ 120 VAC, 28 VDC 10 AMPS @ 120/240 VAC, 28 VDC 10 AMPS @ 120/240 VAC, 28 VDC Silver cadimum Oxide Silver cadimum Oxide Silver Cadimum Oxide Silver Cadimum Oxide Silver Cadimum Oxide 50 MILLIOHMS Max Initial 50 MILLIOHMS Max Initial 50 MILLIOHMS Max.initial 50 MILLIOHMS Max.initial 50 MILLIOHMS Max.initial 2000 V rms 2000 V rms 1500 V rms 1500 V rms 120 VAC 24 VDC 90 to 130 VAC 20 to 32 VDC 120 VAC 24 VDC 90 to 130 VAC 20 to 32 VDC 24 to 240VAC 12 to 115-125 VDC 85% Of Nominal 80% Of Nominal 24 to 240VAC 12 to 115-125 VDC 85% Of Nominal 80% Of Nominal DC MODELS ONLY DC MODELS ONLY DC MODELS ONLY DC MODELS ONLY - 30˚ C to + 55˚ C - 55˚ C to + 85˚ C - 30˚ C to + 55˚ C - 55˚ C to + 85˚ C - 10˚ C to + 55˚ C - 55˚ C to + 85˚ C - 10˚ C to + 70˚ C - - 10˚ C to + 70˚ C - 0.1 to 120 Seconds 0.1 to 120 Seconds 0.1 to 120 Seconds 1.0 to 180 Seconds 0.6 to 60 Seconds 0.1 to 300 Seconds 0.1 to 300 Seconds 100,000 Operations 5,000,000 Operations 100,000 Operations 5,000,000 Operations 100,000 Operations 5,000,000 Operations 100,000 Operations 10,000,000 Operations 100,000 Operations 10,000,000 Operations 1500 V rms 120 VAC 24 VDC 90 to 130 VAC 20 to 32 VDC DC MODELS ONLY H W L 1.40 X 1.53 X 1.90 PAGE 120, 121 PAGE 111 H W L 1.40 X 1.53 X 3.52 LG. 1.40 X 1.53 X 3.02 MED. H HW W L L 1.40 X 1.53 X 3.52 1.37 X .1.50 X 3.35 1.37 X 1.37 X 3.0 PAGE 122, 123 PAGE 124 PAGE 125, 126 PAGE 127, 128 H W L H W L WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 91 Magnecraft Struthers-Dunn TIME DELAY RELAYS & SENSORS 236/237/238 SEE SECTION 10 FOR SOCKETS 12 PIN STYLE PLUG-IN. WITH LOCKING CLIP 236 - ON DELAY, 237 OFF DELAY, 238 - ONE SHOT SCREWDRIVER OR EXTERNAL RESISTOR ADJUSTABLE. ±10 % REPEATABILITY. 246/247 235 CURRENT SENSOR 349 VOLTAGE SENSOR SQUARE BASE PLUG-IN. 12 PIN STYLE PLUG-IN. WITH LOCKING CLIP 1.5 TO 15 AMP SENSING 85 to 135 VAC 50 TO 400 STYLE 246 - ON DELAY, RANGE. Hz SENSING RANGE. STYLE 247 - OFF DELAY ±2% REPEATABILITY 1 AND 3 PHASE SENS±3% REPEATABILITY. SPDT CONTACT ING. ARANGEMENTS 2 - 4 POLE CONTACT LARGE CHOICE OF ARANGEMENTS OPTIONS FIELD ADJUSTABLE WITH KNOB LARGE CHOICE OF OPTIONS 12 PIN STYLE PLUG-IN. WITH LOCKING CLIP 236 VOLTAGE SENSOR SQUARE BASE OR OCTAL PLUG-IN UP TO 552 VAC OR 30 VDC SENSING RANGE. ±1% REPEATABILITY LED POWER INDICATOR FIELD ADJUSTABLE WITH SCREW DRIVER OR KNOB 1,2 & 3 POLE 10 AMP SWITCHING SPDT, DPDT, 3PDT SEE CATALOG PAGE SPDT SEE CATALOG PAGE SPDT, DPDT 10 AMPS @ 120/240 VAC, 28 VDC 10 AMPS @ 120/240 VAC, 28 VDC 10 AMPS @ 120VAC/ 28 VDC 10 AMPS @ 120/240 VAC, 28 VDC 10 - 13 AMPS @ 120/240 VAC, 28 VDC Silver Cadmium Oxide or Gold Diffused 50 MILLIOHMS Max. Initial Silver Cadmium Oxide Silver Cadimum Oxide 50 MILLIOHMS Max.initial 1500 V rms Silver Cadmium Oxide or Gold Diffused 50 MILLIOHMS Max. Initial Silver Cadmium Oxide 50 MILLIOHMS Max. Initial 2500 V rms 1500 V rms 50 MILLIOHMS Max. Initial 2000 V rms 1500 V rms 24 to 240VAC 12 to 115-125 VDC 85% Of Nominal 80% Of Nominal 24 to 240 VAC 12 TO 110-125 VDC - 120 VAC - 120VAC - 120 to 480 VAC 24 VDC - DC MODELS ONLY DC MODELS ONLY - N/A N/A - 10˚ C to + 70˚ C - - 10˚ C to + 70˚ C - - 30˚ C to + 55˚ C - 40˚ C to + 85˚ C - 10˚ C to + 60˚ C - 30˚ C to + 55˚ C - 40˚ C to + 85˚ C 0.2 to 200 Seconds 0.1 to 300 Seconds 1.5 to 15 Amps 85 TO 135 VAC SEE CATALOG PAGE 100,000 Operations 10,000,000 Operations 100,000 Operations 10,000,000 Operations 200,000 Operations 5,000,000 Operations 100,000 Operations 10,000,000 Operations 100,000 Operations 5,000,000 Operations H W L 1.46 X 2.62 X 4.56 PAGE 129, 130 H W L 1.46 X 2.62 X 4.42 PAGE 131 H W L 1.40 X 1.53 X 3.52 PAGE 132 H W L 1.46 X 2.62 X 4.56 PAGE 133 H W L 1.75 X 2.37 X 3.49 1.40 X 1.53 X 2.90 PAGE 134, 135 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 112 DESCRIPTIONS OF TIME DELAY FUNCTIONS APPLICATION DATA WHAT A TIME DELAY RELAY IS: A Time Delay relay is a combination of an electromechanical output relay and a control circuit. The control circuit is comprised of solid state components and timing circuits that control operation of the relay and timing range. Typical time delay functions include On-Delay, Off-Delay, Repeat cycle, One Shot, Batch Control Interval, On-Delay & Off Delay (Combination) and True Off Delay. Each function is explained below. Time delay relays have a broad choice of timing ranges from less than one second to hours. There is a choice of timing controls from calibrated external knob, screwdriver adjusted or internally fixed timing for specific applications. The output contacts on the electromechanical output relay are direct wired to the output terminals. The contact load ratings are specified for each specific type of time delay relay. INPUT POWER ON OFF CLOSED OPEN CONTROL SWITCH TIMING FUNCTIONS: ON-DELAY- (SLOW OPERATE RELAY) Upon application of power to the input, the time delay period begins. At the end of the time delay period, output contacts transfer. Input power must be removed to return output contacts to home position and reset the control circuit. If input power is interrupted before a timing period ends, timing stops. When input power is restored , timing starts from the beginning. Special requirements for Class 211 programmable relays: To function as an On-Delay timer, as described above, a jumper wire must be connected in place of the external control switch. INPUT POWER OUTPUT CONTACTS TIMING FUNCTIONS (Continued) ONE SHOT (MOMENTARY ACTUATION) Continuous power must be applied to the input during all timing sequences. Upon closure of external control Switch, output contacts transfer and timing period begins. When timing period ends, output contacts return home. Once the timing period begins, the control switch may remain closed or opened without affecting timing. To repeat this cycle, the control switch must be open, or opened at the end of the timing period, and then closed to start timing period over again. ON OFF TRANSFERRED HOME DELAY Some typical Applications: Cascade starting, Air Conditioning & heating controls, Burglar Alarms, Power Outage delay, instrument Control. OFF-DELAY (SLOW RELEASE RELAY) Continuous power must be applied to input during all timing sequences. Upon closure of external control switch, output contacts transfer. Upon opening control switch, the timing period begins. When timing period ends, output contacts return home. To repeat this timing cycle, the control switch must be re-closed and then opened. If input power is interrupted during timing cycle, the output contacts return to home position and the control switch must be closed and reopened to start the timing from the beginning. If the control switch closes during a timing period, timing stops and output contacts remain transferred. When control switch is opened, timing will start again from the beginning. The timing period can be extended, repeatedly using the control switch in this way until the last initiated timing period is permitted to end and output contacts return home. INPUT POWER ON OFF CONTROL SWITCH CLOSED OPEN OUTPUT CONTACTS TRANSFERRED HOME DELAY DELAY OUTPUT CONTACTS DELAY TRANSFERRED HOME DELAY Some typical Applications: Vending machines, dispensing controls, machine control, welding control, BATCH CONTROL (INTERVAL) Upon application of power to the input, the output contacts transfer and the delay period begins. At the end of the time delay period, the output contacts return home. Input power must be interrupted to recycle timer. INPUT POWER OUTPUT CONTACTS ON OFF TRANSFERRED HOME DELAY Some typical Applications: Machine control, End of process alarm, Welding control, Photographic timing. ON-DELAY & OFF-DELAY- (COMBINATION) Continuous power must be applied to the input during all timing sequences. Upon closure of the external control switch, first time delay period T1 begins. When T1 period ends, output contacts transfer. Then, When control switch is opened, second delay period T2 begins. When T2 ends, output contacts return home. To repeat this timing cycle, repeat this sequence from the beginning. If the prevailing open or closed status of the control switch is changed during either T1 or T2 Timing periods, timing stops. Position of output contacts remain as they were. Returning control switch to its pre-changed position restarts interrupted timing period from the beginning and normal timing resumes. INPUT POWER ON OFF CLOSED OPEN CONTROL SWITCH OUTPUT CONTACTS T1 T2 T1 Interrupted TRANSFERRED HOME T2 Interrupted CONTROL SWITCH OUTPUT CONTACTS T1 T2 CLOSED OPEN TRANSFERRED HOME Some typical Applications: Air Conditioning, automatic Door Controls, Lighting Controls, burglar alarms, Vending Machines, conveyor systems, instrument control. Some typical Applications: Cascade starting & stopping of heavy loads, laboratory equipment, machine control REPEAT CYCLE (FLASHER) - Upon application of power to the input, the Off time delay Period begins. The contacts transfer at the end of the Off time Delay Period and the ON time delay period begins. At the end of the ON time delay period output contacts return home and OFF time delay period begins again. This sequence will continue as long as input power is supplied to the Input Pins. TRUE OFF DELAY- (SLOW RELEASE) Upon application of power to the input, output contacts transfer. The delay period begins when power is removed from the input. If power is supplied to input during the timing period, time is reset and time delay period starts over again when power is removed from the input. INPUT POWER OUTPUT CONTACTS ON DELAY ON DELAY ON OFF TRANSFERRED HOME OFF DELAY Some typical Applications: Signs, Product testing, signal devices, machine control, Signal warning devices, conveyor control. PAGE 113 INPUT POWER OUTPUT CONTACTS DELAY OFF DELAY ON OFF TRANSFERRED HOME Some typical Applications: Loss of power alarm control, Burglar alarms. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 TIME DELAY RELAYS & SENSORS APPLICATION DATA SELECTING A TIMER'S MODE OF OPERATION Selecting the correct Mode of operation (Timing Function) can be easily done by following the ladder diagram below. When selecting the proper relay for your application, you must determine if the timer will be controlled by input power only, or the use of an external switch. The next item to take into consideration is the load status during the timing cycle(s), and the contact status after the timing cycle. Output status During Timing cycle (s). Power is supplied to Input & External Switch ON/OFF Power is supplied to Input Timing Starts When? OFF ON ON/OFF ON ON NOTE 1 Load Status at end of First Timing cycle. ON OFF ON OFF OFF ON OFF NOTE 3 NOTE 4 OFF ON NOTE 2 Load Status at end of Second Timing cycle. Timer Type. Applicable Time delay relays that apply to Mode of Operation ON DELAY 211PROGX 211 SOX 67 SOX 326X 388 SOX 236X 246XBX 286X OFF OFF NOTE 2 NOTE 5 TRUE OFF DELAY REPEAT CYCLE BATCH CONTROL (INTERVAL) OFF DELAY ONE SHOT 388 SRX 222 PFX 238ABX 211PROGX 211 SRX 237X 327X 388 SRX 247XBX 287X 211PROGX 238X ON/OFF DELAY 211PROGX NOTES: 1. Momentary power supplied to the input. Input power not required for timing cycle. 2. Continues to repeat timing cycles until power is removed from input 3. Upon closure of External switch, relay contacts switch and time period begins. The timing is not affected by the duration of the External switch closure. 4. External switch is maintained closed, relay contacts switch at the end of first timing cycle. 5. External switch is maintained open for second timing cycle. Footnote: ON = Relay coil energized, contacts switched. OFF = Relay coil de-energized, contacts in normal position. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 114 CLASS 211 OCTAL 8 & 11 PIN TIME DELAY RELAY CLASS 211 ± 0.1 % REPEATABILITY DPDT, 10 AMP CONTACTS FIELD ADJUSTABLE TIMING WHEN USED WITH SOCKET 70-464-1 (8PIN) 70-465-1 (11 PIN) UL Recognized COMPLIES WITH File No: E43641 REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION THE CLASS 211 TIME DELAY RELAY MAKES USE OF HYBRID CIRCUITRY, COMBINING INTEGRATED CIRCUITS FOR A MULTITUDE OF TIMING FUNCTIONS, AND THE RELIABILITY OF RELAY TECHNOLOGY. * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) SPECIFICATIONS CLASS 211 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): Timing change over temperature and voltage range: Timing Tolerance high end of range: Timing Tolerance low end of range:: Reset time: CONTACTS Contact Configuration:: Contact Rating: Contact Life: Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: On Delay, Off Delay 0.1 to 1 Sec, thru 8 to 120 Minutes ±0.1% max. or ± 33 mS AC min. or ± 10 mS DC. min.@ Constant voltage & temperature ± 10% - 0 to + 40% + 0 to - 40% 100 Milliseconds Max. DPDT (2 Form C) 10 Amps @ 120VAC/30VDC Resistive Load, 1/2 Hp @ 240 VAC, 1/3 Hp @120 VAC, NEMA B300 Pilot Duty. 200,000 Operations @ 120VAC, 10Amp resistive Load. 1,000,000 Operations @ 120 VAC,5 Amp Resistive Load 2,000,000 Operations @ 120VAC, 2 Amps Resistive Load. 50,000,000 Operations. - 30 ˚C to + 55˚C - 55˚C to + 85˚C 20 mA @ 120 VAC, 40 mA @ 24 VDC, 20 mA @ 48 VDC 80 mA @ 24 VDC, 15 mA @ 230 VAC, 80 mA @ 12 VDC. PROTECTION Reverse Polarity: Transient: Noise Immunity: DC models only UL 508 Surge test: 5000V for 50 uS NEMA ICS2-230 2500 VAC DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 1500 V rms 1000 V rms MECHANICAL Enclosure: Mounting: Operating Position: Weight: Polycarbonate dust cover. Standard 8 or 11 Pin Octal Any 4 oz. (115 grams) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 115 CLASS OCTAL 8 & 11 PIN TIME DELAY RELAY 211 OUTLINE DIMENSIONS Dimensions shown in Inches and (Millimeters) WIRING DIAGRAMS VIEWED FROM PIN END .562 (14.2) ▼ ▲ ▼ ▲ 4 ON DELAY 5 3 6 2 7 1 2.93 (74.4) 8 INPUT 2.37 (60.3) EXTERNAL TRIGGER SWITCH 5 ● ▲ ● 7 6 8 4 5 OFF DELAY ▼ ▲ 6 7 4 8 3 9 2 1 11 1 2 3 ▼ ▲ 1.75 (44.4) 8 PIN OCTAL ON-DELAY 10 INPUT EXTERNAL SWITCH SHALL NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR. 8 9 10 7 11 6 1.75 (44.4) 1 5 4 3 2 11 PIN OCTAL OFF-DELAY PART NUMBERS NOMINAL INPUT VOLTAGE TIMING RANGE CROSS REFERENCE TO POTTER & BRUMFIELD ON DELAY W211ACPSOX-18 W211ACPSOX-5 W211ACPSOX-7 W211ACPSOX-8 W211ACPSOX-60 W211ACPSOX-61 W211ACPSOX-62 W211ACPSOX-63 W211CPSOX-1 W211CPSOX-3 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 0.1 to 1.0 Seconds 0.1 to 10 Seconds 1.0 to 180 Seconds 2.0 to 300 Seconds 1.0 to 15 Minutes 2.0 to 30 Minutes 4.0 to 60 Minutes 8.0 to 120 Minutes 0.1 to 10 Seconds 1.0 to 180 Seconds CDB-38-70001 CDB-38-70003 * CDB-38-70005 * CGB-38-70005M CGB-38-70010M CGB-38-70050M CB-1007B70 CDD-38-30003 * CDD-38-30005 * 120 VAC 120 VAC 120 VAC 120 VAC 24 VDC 24 VDC 0.1 to 10 Seconds 1.0 to 180 Seconds 2.0 to 300 Seconds 1.0 to 15 Minutes 0.1 to 10 Seconds 1.0 to 180 Seconds CHB-38-70011 CHB-38-70013 CHD-38-30011 CHD-38-30013 OFF DELAY W211ACPSRX-5 W211ACPSRX-7 W211ACPSRX-8 W211ACPSRX-60 W211CPSRX-1 W211CPSRX-3 * ADDITIONAL EQUIVALENTS TO P&B W211ACPSOX-5 CGB-38-70010S CHB-38-70001 CKB-38-70010 CB-1003B-70 W211CPSOX-1 CHD-38-30001 CB-1028D-30 W211ACPSOX-7 CKB-38-70180 CHB-38-70003 CB-1005B-70 W211CPSOX-3 CHD-38-30003 CB-1030D-30 SEE SECTION 10 FOR MATING SOCKETS PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 116 CLASS PROGRAMMABLE TIME DELAY RELAY 211PROGX CLASS 211 PROGRAMMABLE TIME DELAY RELAY ± 0.1 % REPEATABILITY 3 INPUT VOLTAGE RANGES ✝ 4 PROGRAMMABLE FUNCTIONS ✝ 62 PROGRAMMABLE TIMING RANGES RATED AT 10 AMPS, DPDT CONTACTS WHEN USED WITH SOCKET 70-465-1 AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) OUTLINE DIMENSIONS Shown in Inches and (Millimeters) .562 (14.2) 2.93 (74.4) TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): Timing change over temperature and voltage range: Timing Tolerance: Reset time: CONTACTS Contact Configuration: Contact Rating: Mechanical Life: 9 8 11 10 7 On Delay, Off Delay, One Shot, On & Off Delay 0.1 to 1 Sec, thru 12 to 120 Minutes ±0.1% max. or ± 33 mS AC min., or ± 10 mS DC. ± 10% ± 20 % 100 mS Relay On (200 mS max Relay Off) DPDT (2 Form C) 10 Amps @ 120VAC/30VDC Resistive Load, 1/2 Hp @ 240 VAC, 1/3 Hp @ 120 VAC, NEMA B300 Pilot Duty. 200,000 Operations @ 120VAC, 10 Amp resistive Load. 1,000,000 Operations @ 120VAC, 5 Amp Resistive Load 2,000,000 Operations @ 120VAC, 2 Amps Resistive Load. 100,000,000 Operations. INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: - 30 ˚C to + 55˚C - 40˚C to + 85˚C 45 mA Max.. PROTECTION Reverse Polarity: Transient: Noise Immunity: Yes UL 508 Surge test: 5000V for 50 uS NEMA ICS2-230 2500VAC DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 1500 V rms 1000 V rms MECHANICAL Enclosure: Mounting: Mounting Position: Weight: Polycarbonate dust cover. Standard 11 Pin Octal Any 4 oz. (115 grams) 1 6 1.75 (44.45) *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION SPECIFICATIONS CLASS 211PROG TDR Contact Life: 2.37 (60.19) ✝ SELECTION OF TIMING RANGE AND TIMING FUNCTIONS ARE OBTAINED BY SETTING SWITCH POSITIONS IN A DIP SWITCH BANK COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. UL Recognized File No: E43641 * RELEVANT IEC CONTACT UTILIZATION CATEGORIES THE CLASS 211 TIME DELAY RELAY MAKES USE OF HYBRID CIRCUITRY, COMBINING INTEGRATED CIRCUITS FOR A MULTITUDE OF TIMING FUNCTIONS, AND THE RELIABILITY OF RELAY TECHNOLOGY. SEE SECTION 10 FOR MATING SOCKETS 5 4 3 2 11 PIN OCTAL PLUG-IN WIRING DIAGRAMS VIEWED FROM PIN END ** EXTERNAL CONTROL SWITCH ● ▲ ● + 5 ▼ ▲ 6 7 8 4 3 9 2 1 11 ▼ ▲ 24VAC/VDC 10 - INPUT 120VAC 50/60 Hz To function as a On-Delay timer, a jumper wire must be connected in place of the external control switch. PAGE 117 NOMINAL TIMING INPUT RANGE VOLTAGE ON DELAY, OFF DELAY, ONE SHOT, ON & OFF DELAY 62 Programmable 120 VAC, 50/60Hz W211PROGX-1 Timing Ranges. 24VAC/VDC on Pin 7 PART NUMBER PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. **EXTERNAL CONTROL SWITCH REQUIRED FOR OFF DELAY, ONE SHOT AND ON & OFF DELAY FUNCTIONS. EXTERNAL SWITCH SHALL NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS MINIATURE 5 AMP TIME DELAY RELAY 67 CLASS 67 TIME DELAY RELAY ± 2% REPEATABILITY DC OPERATION PLUG-IN/SOLDER TERMINALS UL Recognized File No: E43641 SPECIFICATIONS CLASS 67 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): Reset time: CONTACTS Contact Configuration: Contact Rating: Contact Life: On Delay, 0.1 to 240 Seconds ± 2% max. @ Nominal Voltage, 25˚C 100 Milliseconds Max Mechanical Life: DPDT ( 2 Form "C"). 5 Amps @ 120VAC/28 VDC Resistive 50,000 Operations @ 120 VAC 5 Amps Resistive 1,500,000 Operations @ 120VAC, 2 Amps resistive Load. 12,000,000 Operations @ 120 VAC 1Amp Resistive Load 50,000,000 Operations INPUT Nominal Input Voltage: Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: 12 VDC, 24 VDC -30˚C to + 55˚C -50˚C to +85˚C 40 mA @ 24 VDC, 80 mA @ 12 VDC PROTECTION Reverse Polarity: Transient: DC models only Twice Nominal Voltage for 1 Millisecond DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 500 V rms 1250 V rms MECHANICAL Enclosure: Mounting: OUTLINE DIMENSIONS Dimensions shown are in Inches and ( Millimeters). 1.18 Max. (30.2) .094 (2.3) 3-48UNC-2A Thd. .170 (4.3) Elongated Hole .100 x .040 ( 2 x .1) Special Note: .400 (10.1) .458 (11.6) .200 Max. (5.1) All Contact Terminals are .010 Thick all coil terminals are .018 Thick. Polycarbonate dust cover. Socket Plug-in/Solder. Also Available with P.C. Terminals. 1.2 oz. 35.2 Grams Weight: .734 (18.6) 1.37 (34.9) WIRING DIAGRAM Use 6 Pole Socket with plug-in style relays. . 16 6 7 14 15 5 + 1 4 VIEWED FROM PIN END PART NUMBERS NOMINAL INPUT VOLTAGE TIMING RANGE CROSS REFERENCE TO POTTER & BRUMFIELD "ON" DELAY W67CPSOX-1 W67CPSOX-2 12 VDC 24 VDC 0.1 to 30 Seconds R12-3012X2E1 0.1 to 30 Seconds R12-3024X2E1 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION OTHER COIL VOLTAGES, TIMING RANGES, P.C. TERMINALS AND 4PDT CONTACT COMBINATION AVAILABLE ON SPECIAL ORDER. 120 VAC INPUT DESIGN AVAILABLE, CONTACT FACTORY. .280 (7.11) .56 (14.2) CHASSIS CUTOUT for panel mounting. .790 (19.8) .656 (16.7) .352 (8.9) .140 (3.5) .109 DIA. (2.77) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 118 CLASS OCTAL 8 PIN REPEAT CYCLE TIMER 222 CLASS 222 ± 0.1 % REPEATABILITY DPDT, 10 AMP CONTACTS FIELD ADJUSTABLE ON AND OFF TIME. COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. UL Recognized File No. E43641 *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION SEE SECTION 10 FOR MATING SOCKETS * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) SPECIFICATIONS CLASS 222 REPEAT CYCLE TIMER TIMING Operating Modes Available: Timing Adjustments Available: Repeatability (repeat Accuracy when Stabilized): THE CLASS 222 REPEAT CYCLE TIME DELAY RELAY CAN BE ADJUSTED TO ACHIEVE INDEPENDENT TIME SETTINGS FOR BOTH "ON" AND "OFF" TIMING RANGES. Timing change over temperature and voltage range: Timing Tolerance high end of range: Timing Tolerance low end of range:: Reset time: .562 (14.2) CONTACTS Contact Configuration: Contact Rating: Contact Life: 2.93 (74.4) Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: 2.37 (60.3) 7 6 5 8 4 1 1.75 (44.4) 2 3 8 PIN OCTAL ON-DELAY WIRING DIAGRAMS VIEWED FROM PIN END ▼ ▲ Repeat cycle timing only. 0.1 to 1 Sec, to 24 hours ±0.1% max. or ± 33 mS AC min. or ± 10 mS DC min. at constant voltage & temperature.. ± 10% - 0 to + 40% + 0 to - 40% 100 Milliseconds Max. DPDT (2 Form C) 10 Amps @ 120VAC/30VDC Resistive Load, 1/2 Hp @ 240 VAC, 1/3 Hp @ 120 VAC, NEMA B300 Pilot Duty. 200,000 Operations @ 120VAC, 10Amp resistive Load. 1,000,000 Operations @ 120 VAC 5 Amp Resistive Load 2,000,000 Operations @ 120VAC 2 Amps Resistive Load. 50,000,000 Operations. - 30 ˚C to + 55˚C - 55˚C to + 85˚C 25 mA @ 120 VAC, 45 mA @ 24 VDC, 24 mA @ 48 VDC 85 mA @ 24 VDC, 25 mA @ 230 VAC. PROTECTION Reverse Polarity: Transient: Noise Immunity: DC models only UL 508 Surge test: 5000V for 50 uS NEMA ICS2-230 2500VAC DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 1500 V rms 1000 V rms MECHANICAL Enclosure: Mounting: Mounting Position: Weight: Polycarbonate dust cover. Standard 8 Pin Octal Any 5 oz. (132 grams) NOMINAL INPUT VOLTAGE TIMING RANGE "ON" (T1) TIMING TIMING RANGE "OFF" (T2) TIMING CROSS REFERENCE TO POTTER & BRUMFIELD 120 VAC 120 VAC 120 VAC 0.1 to 10 Seconds 3 to 300 Seconds 2 to 30 Minutes 0.1 to 10 Seconds 3 to 300 Seconds 2 to 30 Minutes CRB-48-70010 - ▼ ▲ 4 5 6 3 2 7 1 8 INPUT PART NUMBERS REPEAT CYCLE W222ACPFX-11 W222ACPFX-16 W222ACPFX-27 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. OTHER VOLTAGES AND TIMING RANGES AND AVAILABLE THRU SPECIAL ORDER. CONTACT FACTORY. PAGE 119 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS 12 AMP ADJUSTABLE TIME DELAY RELAY UL Recognized File No: E43641 388 CLASS 388 SHORT BODY EXTERNAL RESISTANCE ADJUSTABLE COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 ± 3 % REPEATABILITY DPDT, 12 AMP CONTACTS FIELD ADJUSTABLE TIMING "ON" or "OFF" DELAY FUNCTIONS PLUG-IN STYLE (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) SPECIFICATIONS CLASS 388 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability: Percent Timing change over temperature and voltage Range: Timing Tolerance high end Timing Tolerance low end: CONTACTS Contact Configuration: Contact Rating: Contact Life: Mechanical Life: On Delay, Off Delay .1 to 1 Seconds to 24 Hours ±0.1% max. or ± 33 mS AC min. or ± 10 mS DC.@ Constant Voltage & Temperature. FLANGE MOUNT STYLE ± 10% - 0 to + 40% + 0 to - 40% DPDT (2 Form C) 12 Amps @ 120 VAC/28 VDC Resistive 1/3 HP, 120 VAC, 1/2 HP, 240 VAC B300 Pilot Duty. 100,000 Operations @ 120 VAC 12 Amps Resistive Load. 1,000,000 Operations @ 28 VDC 5 Amps Resistive Load. 5,000,000 Operations INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: - 30 ˚C to + 55˚C - 55˚C to + 85˚C 20 mA @ 120 VAC, 60 mA @ 24 VDC, PROTECTION Reverse Polarity: Transient: DC models only Twice nominal voltage for 1 millisecond DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 1500 V rms 1000 V rms MECHANICAL Enclosure: Operating Position: Weight: Polycarbonate dust cover. Any 3 oz. 96 grams WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 120 CLASS 388 12 AMP ADJUSTABLE TIME DELAY RELAY OUTLINE DIMENSIONS Dimensions Shown in "Inches " & (Millimeters). 2.90 Max. (73.8) 2.50 (63.5) 1.53 Max. (38.8) .187 (4.74) Q.C. Terminals 1.90 Max. (48.4) 1.40 Max. (35.7) 1 4 2 5 3 6 7 8 9 A B THE PLUG-IN STYLE TIMER HAS THE SAME CASE DIMENSIONS AS THE FLANGE MOUNT STYLE EXCEPT IT HAS NO FLANGE AND IT IS ALSO SOCKET MOUNTABLE. WIRING DIAGRAMS FOR FIXED STYLE TIME DELAY RELAYS Voltage must be applied to terminals "A" & "B" continuously. EXTERNAL RESISTOR EXTERNAL RESISTOR 1 2 3 4 5 6 7 8 9 A EXTERNAL SWITCH B + INPUT OFF DELAY 1 2 3 4 5 6 7 8 9 B A + INPUT ON DELAY THE EXTERNAL TRIGGER SWITCH SHOULD NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE SOURCE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR. NOMINAL TIMING EXTERNAL INPUT RANGE RESISTOR VOLTAGE ON DELAY PLUG-IN STYLE 0.1 to 10 Seconds W388ACPSOX-1 120 VAC 20K OHMS 1.0 to 120 Seconds PER SECOND W388ACPSOX-2 120 VAC 16 K OHMS 0.1 to 10 Seconds W388CPSOX- 1 24 VDC 1.0 to 120 Seconds PER SECOND W388CPSOX-2 24 VDC ON DELAY SURFACE MOUNT FLANGE STYLE 0.1 to 10 Seconds W388ACQSOX-1 120 VAC 20 K OHMS 1.0 to 120 Seconds PER SECOND W388ACQSOX-2 120 VAC 1.0 to 120 Seconds W388CQSOX-2 24 VDC OFF DELAY PLUG-IN STYLE 1.0 to 120 Seconds 16KΩ per Second W388CPSRX-22 24 VDC PART NUMBER CROSS REFERENCE TO POTTER & BRUMFIELD CUF-41-70010 CUF-41-70120 CUH-41-30010 CUH-41-30120 CUF-42-70010 CUF-42-70120 CUH-42-30120 - PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE SECTION 10 FOR MATING SOCKETS PAGE 121 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 12 AMP ADJUSTABLE TIME DELAY RELAY CLASS 388 CLASS 388 ADJUSTABLE UL Recognized File No: E43641 COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. CHOICE OF LONG or MEDIUM BODY ± 0.1 % REPEATABILITY DPDT, 12 AMP CONTACTS FIELD ADJUSTABLE TIMING "ON" or "OFF" DELAY FUNCTIONS *1EC = INTERNATIONAL ELECTROTECHNICAL ICOMMISSION * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) SPECIFICATIONS CLASS 388 TIME DELAY RELAYS TIMING Operating Modes Available: Timing Adjustments Available: Repeatability: Timing change over temperature and voltage Range: Timing Tolerance high end: Timing Tolerance low end: Reset Time: CONTACTS Contact Configuration: Contact Rating: Contact Life: Mechanical Life: INPUT Temperature Range (Operate): Temperature Range (Storage): Steady State Input Current: PROTECTION Reverse Polarity: Transient: Noise Immunity: On Delay, Off Delay .1 to 1 Seconds to 8 to 120 Minutes ±0.1% ± 33 mS AC min. or ± 10 mS DC. @ Constant Voltage & Temperature. ± 10% - 0 to + 40% + 0 to - 40% 100 mS Max. DPDT (2 Form C) 12 Amps @ 120 VAC/28 VDC Resistive 1/3 HP, 120 VAC, 1/2 HP, 240 VAC NEMA B300 Pilot Duty. 100,000 Operations @ 120 VAC 12 Amps Resistive Load. 1,000,000 Operations @ 120 VAC 5 Amps Resistive Load 2,000,000 Operations @ 120 VAC 2 Amps Resistive Load. 5,000,000 Operations - 30 ˚C to + 55˚C - 55 ˚C to + 85˚C 20 mA @ 120 VAC, 60 mA @ 24 VDC, 20mA @ 48 VDC, 80 mA @ 24 VAC, 15 mA @ 230 VAC, 120mA @ 12 VDC DC models only UL 508 Surge test: 5000V for 50 uS (Long Body Only). Twice Nominal for 1 Millisecond (Medium Body Only). NEMA ICS2-230: 2500 VAC (Long Body Only). DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 2000 V rms 1000 V rms MECHANICAL Enclosure: Terminals: Mounting Position: Weight: Polycarbonate dust cover. 3/16" Q.C. Terminals. P.C. Available. Any Aprox. 4 oz., 96 grams WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 122 CLASS 12 AMP ADJUSTABLE TIME DELAY RELAY 388 OUTLINE DIMENSIONS Dimensions are Shown In Inches and (Millimeters). 1 4 2 5 3 6 7 8 9 A 1.40 (35.7) B 1.53 (38.8) .312 (7.9) .625 2.90 Max. (Long Body) (15.8) (73.8) 2.40 Max. (Medium Body) (61.1) WIRING DIAGRAMS FOR ADJUSTABLE STYLE TIME DELAY RELAYS Voltage must be applied to terminals "A" & "B" continuously. EXTERNAL TRIGGER SWITCH 1 2 3 1 2 3 1 2 3 4 5 6 4 5 6 4 5 6 7 A 8 9 7 B A + INPUT OFF DELAY LONG BODY 8 + INPUT 9 7 B A - ON DELAY LONG & MEDIUM BODY EXTERNAL TRIGGER SWITCH 8 9 B INPUT + OFF DELAY MEDIUM BODY THE EXTERNAL TRIGGER SWITCH SHOULD NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE SOURCE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR. PART NUMBERS NOMINAL INPUT VOLTAGE TIMING RANGE ON DELAY - LONG BODY 0.1 to 10 Seconds 120 VAC W388ACPSOX-42 1.0 to 180 Seconds 120 VAC W388ACPSOX-44 OFF DELAY - LONG BODY W388CPSRX-2 24 VDC 0.1 to 10 Seconds W388CPSRX-4 24VDC 1.0 to 180 Seconds OFF DELAY - MEDIUM BODY CROSS REFERENCE TO POTTER & BRUMFIELD - W388ACPSRX-101 120 VAC 1.0 to 120 Seconds ON DELAY - MEDIUM BODY - W388ACPSOX-101 120 VAC 1.0 to 120 Seconds OFF DELAY - MEDIUM BODY CLB-51-70120 * W388CPSRX-23 24 VDC 1.0 to 120 Seconds ON DELAY - MEDIUM BODY - W388CPSOX-101 - 24 VDC 1.0 to 120 Seconds * THE CASE LENGTH ON THE MAGNECRAFT MEDIUM BODY IS 2.40 LONG VS P&B, 2.156 LONG. PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE SECTION 10 FOR MATING SOCKETS PAGE 123 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS ADJUSTABLE TRUE OFF DELAY RELAY UL Recognized File No: E43641 COMPLIES WITH REQUIREMENTS OF * IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE. *1EC = INTERNATIONAL ELECTROTECHNICAL COMMISSION 388 CLASS 388 TRUE OFF DELAY DOES NOT REQUIRE CONTROL POWER DURING TIMING CYCLE ± 3% REPEAT TIMING ACCURACY FIELD ADJUSTABLE * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 (SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.) SPECIFICATIONS CLASS 388 TRUE OFF DELAY TIMING Operating Modes Available: Timing Adjustments Available: Repeatability: Reset time: True Off Delay 0.1 to 10 Seconds thru 0.5 to 5 Minutes ± 3% @ Nominal Voltage & 25˚C 100 mS Max. INPUT Temperature Range Operate: Temperature Range Storage: Input Current: - 10˚C to + 55˚C - 40˚C to + 85˚C 10 mA @ 120VAC, 15 mA @ 24VDC fixed CONTACTS Contact Configuration: Contact Rating: The Class 388 Adjustable True Off Delay Relay combines a Solid State Timing circuit with a state of the art Magnetic Latching relay. This combination allows the relay to Pull-in when power is applied to the input. Timing starts when power is removed from the input and at the end of the preset timing period the relay will dropout. DPDT (2 Form C) 12 Amps @ 120 VAC/28 VDC Resistive 1/3 HP, 120 VAC, 1/2 HP, 240 VAC NEMA B300 Pilot Duty. 100,000 Operations @ 120 VAC 12 Amps Resistive Load. 1,000,000 Operations @ 120 VAC 5 Amps Resistive Load 2,000,000 Operations @ 120 VAC 2 Amps Resistive Load. Contact Life: DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: Transient: Reverse Polarity Protection: WIRING DIAGRAM Viewed from Pin End 2000 V rms 1000 V rms 2000 VAC for 50 Microseconds (DC Models Only) MECHANICAL Enclosure: Mounting: Terminals: Weight: 1 2 3 4 5 6 7 8 9 B A Polycarbonate dust cover Square Base Plug-in 3/16" X .020" Quick Connect, P.C. Terminals Available 4 oz. 96 grams + INPUT Observe polarity on DC models OUTLINE DIMENSIONS Dimensions are Shown In Inches and Millimeter .312 (7.9) 1.53 (38.8) 1 4 2 5 3 6 7 8 9 A B 1.40 (35.7) 2.90 Max. (73.8) .625 (15.8) PART NUMBERS NOMINAL INPUT VOLTAGE TIMING RANGE AC OPERATED W388ACPSRX-29 W388ACPSRX-30 DC OPERATED W388CPSRX-35 W388CPSRX-36 120 VAC 120 VAC 0.6 to 60 Seconds 0.1 to 10 Seconds 24 VDC 24 VDC 0.1 to 10 Seconds 0.6 to 60 Seconds PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 124 SERIES 286/287 10 AMP SQUARE BASE TIME DELAY RELAY SERIES 286 ON DELAY, 287 OFF DELAY AC OR DC INPUT 1, 2 OR 3 POLE 10 AMP CONTACTS. UL Recognized File No. E13224 GENERAL SPECIFICATIONS SERIES 306 TIMER INPUT Coil Voltage Nominal Voltage: AC: 24 to 240, DC: 12 to 125 Minimum Oper. Voltage: AC - 85% of Nominal DC - 80% of Nominal Max. allowed voltage: 110% of nominal voltage CONTACTS Contact Material: Rating: The series 286 On Delay & 287 Off Delay Time Delay Relays have timing ranges from 0.1 to 300 Seconds. The 286 timer has up to three poles and the 287 timer has up to two poles. The 286 & 287 time delay relays are rated at 10 Amps, 120/240 Vac, 28 Vdc. SEE SECTION 10 FOR MATING SOCKETS Silver Cadmium Oxide. 10 Amps @ 120/240 VAC 10 Amps @ 28 VDC 1/3 Hp@ 120AC 1/2 Hp @ 240 VAC OPERATIONAL CHARACTERISTICS Repeatability: ± 3% @ 20˚C to 25˚C (AC +16 mS) Accuracy: Adjustable ± 10% Within temperature & voltage range. Fixed: ± 10% @ 25˚C Recycle Time: 100 mS up to 60 Seconds\ 150 mS, 60 to 300 Seconds INSULATION CHARACTERISTICS Dielectric Strength: All Mutually Insulated Points: Insulation Resistance: Transient Protection: False Contacting: Inverse polarity protection: ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: Struthers-Dunn Typical Part Number 10˚C to +70 ˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear Polycarbonate 5.0 oz approx. (142 g) WIRING DIAGRAM 286 XAX C 001 F 120A Series 286 - ON DELAY 287 - OFF DELAY Viewed from Terminal Side EXTERNAL RESISTOR Contact Arrangements XAX (SPDT) XBX (DPDT) XCX (3PDT) Mounting Options C Plug-in C1Note 1 Bracket Note 1 Top Stud CS1 C2 Side Tapped Hole CS2 Side Stud + Timing Ranges 0.1 - 1.0 Sec - Code 001 0.2 - 2.0 Sec - Code 002 1.0 - 10 Sec - Code 010 3.0 - 30 Sec - Code 030 6.0 - 60 Sec - Code 060 18 - 180 Sec - Code 180 30 - 300 Sec - Code 300 Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 115-125 (Add "D") (F * Models) - timing code does not apply. Specify single delay time requirement (R ** Models)- Available only for SPDT and DPDT models. External potentiometer required. Example of typical fixed time delay relay part number- 286XBXCS1-3.5F-120A (ON DELAY, DPDT, TOP STUD, 3.5 SEC FIXED, 120 VAC COIL INPUT) + EXTERNAL RESISTOR EXTERNAL SWITCH 287 MODEL ONLY 1 2 3 1 2 3 4 5 6 4 5 6 7 8 9 7 8 9 A INPUT B - 1 2 3 4 5 6 7 8 9 A INPUT B + B A INPUT EXTERNAL - SWITCH 287 MODEL ONLY 286XBX (DPDT) 287XBX (DPDT) 286XAX (SPDT) 287XAX (SPDT) Adjustment Options Adjustment Knob) - No Code Fixed Delay - Specify Fixed Time & Code F * Remote Adjustment - Code R ** PAGE 125 500 V rms across open contacts 1500 V rms between current carrying parts 1000 Megohms min. @ 500 VDC. 5 mS, 0 to 2000 V 20 uSec peak No false contacting is power is interupted during timing. DC coil are polarity protected. - SEE SECTION 10 FOR MATING SOCKETS - ON DELAY 286XCX Notes: Note 1: Bracket & top stud Not available with adjustable timing. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES 10 AMP SQUARE BASE TIME DELAY RELAY 286/287 OUTLINE DIMENSIONS Dimensions shown are in INCHES and (millimeters) SIDE STUD OR TAPPED HOLE, ADJUSTABLE TIMING PLUG-IN, ADJUSTABLE TIMING .125 (3.17) .625 (15.87) .625 (15.87) Anti-rotation Tab Fits 0.177 dia. hole (No. 16 Drill) CODE C CODE C2, CS2 2.90 Max. (73.66) 2.90 Max. (73.66) .437 (11.1) 12 12 6-32 tapped hole or 6-32 stud 1.125 Max. (28.57) 6-32 Stud .281 typ. (7.14) .281 typ. (7.14) 1.50 Max. (38.1) 1.375 Max. (34.9) .296 (7.54) 1.375Max. (34.9) 1.50 Max. (38.1) 1.375Max. (34.9) 1.50 Max. .160 (38.1) (4.06) PLUG-IN FIXED OR REMOTE TIMING 1.375Max. (34.9) 1.50 Max. (38.1) BRACKET FIXED OR REMOTE TIMING 1.875 Max. (47.62) CODE C 1.90 Max. (48.26) CODE C1 2.90 Max. (73.66) 2.50 (63.5) .281 typ. (7.14) .281 typ. (7.14) TERMINALS .187 X .020 (4.74 X .508) TERMINALS .187 X .020 (4.74 X .508) SIDE TAPPED HOLE, FIXED OR REMOTE TIMING SIDE STUD, FIXED OR REMOTE TIMING .125 Max. (3.17) 1.375Max. (34.9) .125 Max. (3.17) 1.50 Max. (38.1) Anti-rotation Tab Fits 0.177 dia. hole (No. 16 Drill) CODE CS2 .437 (11.1) 1.375Max. (34.9) 1.50 Max. (38.1) CODE C2 .437 (11.1) 1.875 Max. (47.62) 12 12 Anti-rotation Tab Fits 0.177 dia. hole (No. 16 Drill) 1.875 Max. (47.62) 6-32 Stud 6-32 Tapped hole .281 typ. (7.14) .296 (7.54) 6-32 STUD .125 Max. (3.17) .281 typ. (7.14) 1.125 Max. (28.57) 1.125 Max. (28.57) TOP STUD FIXED OR REMOTE TIMING .375 (9.52) .281 (7.14) .437 (11.11) CODE CS1 1.50 Max. (38.1) 1.875 Max. (47.62) 1 4 2 5 3 6 7 8 9 A 1.375 Max. (34.9) B ALL TERMINALS .187 X .020 (4.74 X .508) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 126 SERIES OCTAL 8 & 11 PIN TIME DELAY RELAY 326/327 SERIES 326 ON DELAY, & 327 OFF DELAY AC OR DC INPUT 1, 2 OR 3 POLES 8 OR 11 PIN OCTAL BASES TIMING: FIXED, ADJUSTABLE OR REMOTE UL Recognized File No. E13224 GENERAL SPECIFICATIONS SERIES 306 TIMER INPUT Coil Voltage Nominal Voltage: Minimum Oper. Voltage: Max. allowed voltage: CONTACTS Contact Material: Rating: AC: 24 to 240, DC: 12 to 125 AC - 85% of Nominal DC - 80% of Nominal 110% of nominal voltage Silver Cadmium Oxide. 10 Amps @ 120/240 VAC 10 Amps @ 30 VDC 1/3 Hp@ 120AC 1/2 Hp @ 240 VAC OPERATIONAL CHARACTERISTICS Repeatability: DC: ± 3% @ 20˚C. AC: ± 3% +16 mS @ 20˚C. Accuracy: Adjustable ± 10% Within temperature & voltage range. Switching time of output relay: 20 mS Min. waiting time before starting next cycle (reset time): 100 mS (for timing cycle up to 60 sec.) 150 mS (for timing cycle 60 to 300 sec) INSULATION CHARACTERISTICS Dielectric Strength: 500 V rms across open contacts All Mutually Insulated Points 1500 V rms between mutually insulated conductive elements. Insulation Resistance: 1000 Megohms min. @ 500 VDC. Transient Protection: 5 mS, 0 to 2000 V 20 uSec peak ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: -10˚C to +70 ˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear Polycarbonate 5.0 oz approx. (142 g) Struthers-Dunn Typical Part Number 326 XAX 48P 001 F 120A Series 326 - 0N DELAY 327 - OFF DELAY Contact Arrangements XAX (SPDT) XBX (DPDT) XCX (3PDT) Construction Style Octal style plug-in - Code 48P Non Standard Wiring - Code 48P-K Timing Ranges 0.1 - 1.0 Sec - Code 001 0.2 - 2.0 Sec - Code 002 1.0 - 10 Sec - Code 010 3.0 - 30 Sec - Code 030 6.0 - 60 Sec - Code 060 18 - 180 Sec - Code 180 30 - 300 Sec - Code 300 Adjustment Adjustment Knob) - No Code Fixed Delay - Specify Fixed Time & Code F * Remote Adjustment - Code R ** Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 115-125 (Add "D") (F * Models) - timing code does not apply. Specify single delay time requirement (R ** Models)- Available only for SPDT and DPDT models. External fixed or adjustable resistor required. Example of typical fixed time delay relay part number- 326XBX48P3.5F-120A (ON DELAY, DPDT, OCTAL PLUG, 3.5 SEC FIXED, 120 VAC POWER INPUT) PAGE 127 SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES OCTAL 8 & 11 PIN TIME DELAY RELAY 326/327 OUTLINE DIMENSIONS Knob not on fixed or remote models .625 (15.87) DIMENSION A ADJUSTABLE WITH KNOB STYLE 3.0 (76.2) FIXED OR REMOTE STYLE 326 Only 2.25 (57.15) Dimensions shown are in INCHES and (millimeters) A 5 4 6 8 PIN OCTAL BASE 2 7 1 6 5 3 7 4 8 3 9 2 1.375 (34.9) 11 PIN OCTAL BASE 10 1 8 11 1.375 (34.9) 1.375 (34.9) WIRING DIAGRAMS (VIEWED FROM PIN END) ✱ ✱ MODELS WITH INTERNAL TIMING RESISTOR SLOW RELEASE SLOW OPERATE 4 ▼ ▲ 5 3 6 2 7 + 1 8 External Switch ▼ ▲ 4 - 6 2 7 + ✝ 326XAX48P 1 INPUT ▼ ▲ 8 3 9 1 11 + ✝ INPUT 326XBX48P 5 7 4 2 - 8 6 5 5 3 ▼ ▲ ▼ ▲ 6 7 4 Jumper 8 3 9 2 10 + - 1 11 ✝ INPUT 326XCX48P ▼ ▲ 10 ✝✝ INPUT 327XBX48P-K Non Standard MODELS WITH EXTERNAL (REMOTE) TIMING RESISTOR SLOW OPERATE SLOW RELEASE ✱ External ✱ External ✱ External Resistance Resistance Resistance ✱ External Resistance 4 + 5 5 3 6 2 7 1 8 ▼ ▲ 6 8 3 9 2 - INPUT 326XAX48P-R + 4 7 4 1 11 ▼ ▲ 10 - INPUT 326XBX48P-R + 5 5 3 6 2 7 1 8 ▼ ▲ - External INPUT Switch 327XAX48P-R 6 7 4 8 3 9 2 + 1 11 INPUT ▼ ▲ 10 - External Switch 327XBX48P-R ✱ External Resistor for remote timing adjustment on models 326 or 327 with code R. ✝ This Diagram also applies to fixed time (code F) models. ✝✝ Duplicates wiring of some similar relays made by others. ✱ ✱ Observe Polarity on DC input models WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 128 SERIES 236/237/238 12 PIN, 10 AMP, TIME DELAY RELAY SERIES 236 ON DELAY, 237 OFF DELAY & 238 BATCH CONTROL INTERVAL (SEE NOTE 3) UL Recognized File No. E13224 AC OR DC INPUT DPDT OR DPDT WITH 1 N.O. CONTACT ON SERIES 236 & 238 12 PIN PLUG-IN WITH LOCKING CLIP TIMING: SCREWDRIVER ADJUSTABLE OR FIXED GENERAL SPECIFICATIONS INPUT Nominal Voltage: Minimum Oper. Voltage: Max. allowed voltage: CONTACTS Contact Material: Rating: The Series 236, 237 and 238 Time Delay Relay consists of a standard 219 industrial relay and a solid state timing module to provide delayed transfer of relay contacts after application of power or activation of control switch. The relay and timing module are enclosed in a flame resistant polycarbonate cover. INSULATION CHARACTERISTICS Dielectric Strength: Inverse polarity protection: Typical Part Number 236 ABX P 020 Series 236 - ON DELAY 237 - OFF DELAY 238 - BATCH CONTROL INTERVAL Contact Arrangements ABX (DPDT & 1 N.O. Contact) 236 & 238 only). XBX (DPDT) 120A Silver Cadmium Oxide. 10 Amps @ 120 VAC res. 10 Amps @ 28 VDC OPERATIONAL CHARACTERISTICS Repeatability: DC: ± 3%: @ 20˚C. AC: ± 3% +16 mS Accuracy: @ 20˚C. Adjustable: ± 10% Within temperature & voltage range. Fixed: ± 10% @ 25˚C Min. waiting time before starting next cycle (Reset Time): 100 mS (for timing cycle up to 60 sec. 150 mS for timing cycle 60 to 300 sec. Insulation Resistance: Transient Protection: False Contacting: Struthers-Dunn AC: 24 to 240, DC: 12 to 125 AC - 85% of Nominal DC - 80% of Nominal 110% of nominal voltage 500 V rms across open contacts, 1500 V rms between output contacts and ground (Locking clip). (See note 4). 1000 Megohms min. @ 500 VDC. 5 mS, 0 to 2000 V 20 uSec peak No false contacting if power is interupted during timing. DC operated are polarity protected. but will not operate if polarity is reversed. ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: - 10˚C to +70 ˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear Polycarbonate 8.6 oz approx. (244 g) Mounting Options P (Plug-in) Timing Ranges 0.2 - 12 Sec - Code 012** 0.2 - 20 Sec - Code 020 2.0 - 200 Sec - Code 200 Adjustment Options Adjustment Screw) - No Code Fixed Delay - Specify Fixed Time & Code F * Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 115-125 (Add "D") Code 012**- 12 Second timing not available on 237 & 238 models. (F * Models) - timing code does not apply. Specify single delay time requirement. Example of typical fixed time delay relay part number- 236XBXP-3.5F-120A (ON DELAY, DPDT, 3.5 SEC FIXED, 120 VAC INPUT POWER). NOTES: 1. 236,237,238 - External resistor (to program time delay) or jumper (for built-in timing) must be connected to terminals 8 & 9. 2. 237 models require an external control switch between terminals 5 & 6. 3. 238 switches contacts when input power is applied and starts timing. Contacts switch back to original position at end of timing cycle. Power must be removed to reset timer. If input power is interupted during the timing cycle, timing ends immediately and the relay resets. 4. Dielectric withstanding voltage testing of the Control circuit may damage the solid state components. PAGE 129 SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES 12 PIN, 10 AMP, TIME DELAY RELAY 236/237/238 OUTLINE DIMENSIONS Dimensions shown are in INCHES and (millimeters) Screwdriver adjust not on fixed models. .313 (7.95) ✝ TIMING * RESISTANCE CHART 3.75 (95.2) 236 RANGE: O.2 TO 12 SEC 20K OHMS PER EA.3 SEC 100 K OHMS MAX. 236 RANGE: 0.2 TO 20 SEC 100K OHMS PER EA.7 SEC 500 K OHMS MAX 237/238 RANGE: 0.2 TO 20 SEC. 100K OHMS PER EA.6 SEC 500 K OHMS MAX. 236 RANGE: 2.0 TO 200 SEC 200K OHMS PER EA.60 SEC 1 MEG OHM MAX. 237/238 RANGE: 2.0 TO 200 SEC 200K OHMS PER EA.55 SEC. 1 MEG OHM MAX. 4.56 (115.8) LOCKING CLIP * USE RESISTOR RATED 1/4 WATT 1 6 12 7 OR MORE. 1.468 (37.2) 2.625 (66.6) EXAMPLE WIRING DIAGRAMS Viewed from Top of Relay ✝ Jumper or External Resistor 12 6+ 1 7- INPUT 7TIMING MODULE TIMING MODULE 237XBXP 236ABXP ON DELAY DOUBLE POLE DOUBLE THROW WITH NORMALLY OPEN CONTACT ✝ If the jumper wire shown in each diagram is replaced by a resistor, delay time will be added to that which is produced by an internal fixed resistor on fixed time models (code F) or any setting on screwdriver adjustable models. See timing resistance chart above. Relay will not operate without a jumper or resistor. Also see note 1. OFF DELAY 6 + 1 External control switch DOUBLE POLE DOUBLE THROW ✝ Jumper or External Resistor 7- 12 INPUT 12 INPUT ✝ Jumper or External Resistor TIMING MODULE BATCH CONTROL INTERVAL (SEE NOTE 3) 6+ 1 DOUBLE POLE DOUBLE THROW 238XBXP WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 130 SERIES 246 & 247 INDUSTRIAL 10 AMP, ON-DELAY & OFF DELAY TIMER SERIES 246 & 247 ± 3% REPEATABILITY OFF DELAY FUNCTION PLUG-IN WITH SELF LOCKING CLIP 1 UL Recognized File No. 13224 TIME MOD 6 12 Listed when used with Type 29390 Socket 1 EXT. TRIGGER 6 12 R .678 (17.2) 247XCXP 7 TIME MOD R EXT. TRIGGER Dimensions shown are in INCHES and (millimeters) 3.75 (95.2) 247XBXP 7 4.56 (115.8) Series 246 CSA Certified ON DELAY FUNCTION 1 TIME MOD CONTACT LOAD SPECIFICATIONS Make Carry Resistive Inductive Voltage 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 7 1 6 10A 3A 1A 3A 0.1A 12 7 1 6 TIME MOD 30A 30A 30A 30A 30A 12 TIME MOD The series 246 & 247 Time Delay Relays are a ON-Delay or Off Delay Function times, with timing ranges from 0.1 to 300 Seconds. The 246 Timer comes in either 2 - 4 poles, and the 247 comes in 2 & 3 Pole models. Both timers incorporate a class 219 relay along with a Solid State timing module. Both timers have a large choice of options and switch up to 30 amp loads. 24 VDC 120 VAC 240 VAC 28 VDC 125 VDC 6 12 246BBXP 246XBXP 246ABAP 1 6 12 7 1.468 (37.2) 2.625 (66.6) 7 For Versions with suffix "69" Permant Magnet Blowouts 125 VDC (SM) 125 VDC (DM) 250 VDC (SM) 250 VDC (DM) 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150mA 0.5A GENERAL SPECIFICATIONS SERIES 246 & 247 TIMER INPUT Coil Voltage Minimum Operate Voltage: Struthers-Dunn Typical Part Number 247 XBX P L - 010 Series 246 - On Delay, Plug-in 2-4 Pole 247 - Off Delay, Plug-in, 2 & 3 Pole Contact Arrangements XBX (2 Form "C") XCX (3 Form "C") ABA (1 Form A & 2 Form C & 1 Form B). BBX (2 Form A & 2 Form C) 246 Only. Standard Features Plug-in With Polycarbonate Cover - Code P Options Indicator Lamp- Code L Manual Actuator - Code M Bifurcated Contacts (5 Amps max) - Code 33 Permanent Magnet, Blowout Code 69 Timing Ranges 0.1 - 1.0 Sec - Code 001 0.2 - 2.0 Sec - Code 002 1.0 - 10 Sec - Code 010 3.0 - 30 Sec - Code 030 6.0 - 60 Sec - Code 060 18 - 180 Sec - Code 180 30 - 300 Sec - Code 300 Adjustment Adjustment Knob) - No Code Fixed - Timing Code does not apply. Ex. 3F = 3 Sec Fixed) Code F Remote Adj. (Ext Pot Required) - Code R Operating Voltage AC; 24, 48, 120, 240 (Add "A" ) DC; 12, 24, 48, 110-125 (Add "D") PAGE 131 Max. allowed voltage: - 120A CONTACTS Contact Material: OPERATIONAL CHARACTERISTICS Repeatability: Accuracy: Recycle Time: False Contacting: Polarity Protection: INSULATION CHARACTERISTICS Dielectric Strength: All Mutually Insulated Points: Transient Protection: Insulation Resistance: ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: AC - 85% of Nominal DC - 80% of Nominal 110% of nominal voltage Silver Cadmium Oxide. - Gold Diffused ± 3% @ 25˚C (AC +16 mS) Adjustable ± 10% Within temperature & voltage range. 100 mS up to 60 Sec., 150 mS 60 to 300 Sec. No false contacting if power is interrupted during timing cycle. DC inputs 500 V rms across open contacts 1500 V rms between current carrying parts & Parts to Ground. 5 mS 0 to 2000V, 20 uSec peak 1000 MΩ min. @ 500 VDC AC: -10˚C to +45˚C @ Rated Operation. DC: -10˚C to +70 ˚C 10 Million Operations no load 100,000 Operations @ Rated Load. 500,000 @ 1/2 Rated Load. Clear polycarbonate 8 oz. (227 g) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS ADJUSTABLE CURRENT SENSING RELAY CLASS 235 CURRENT SENSOR SPECIFICATIONS CLASS 235 CURRENT SENSOR CURRENT SENSING: Sense Current Range: Repeatability: 1.5 to 15 Amperes ± 2% at constant Voltage & Temperature ± 10% over Voltage & Temperature Range. 15 mA (1.7 VA) Input Current: Current Sensor Resistance: 5 Milliohms Temperature Range Operate: - 10˚C to + 55˚C Temperature Range Storage: - 40˚C to + 85˚C CONTACTS Contact Combinations: Contact Rating Transient: SPDT (1 Form C) 10 Amps @ 120 VAC, 6 Amps @ 28 VDC. 2000 V rms for 5 Microseconds LIFE EXPECTANCY; Electrical Mechanical: 200,000 Operations @ Rated Load 5,000,000 Operations @ No Load DIELECTRIC STRENGTH Coil to Contacts: Across Open Contacts: 2500 V rms 500 V rms MECHANICAL Terminals: 235 ± 2 % REPEATABILITY SPDT, 10 AMP CONTACTS FIELD ADJUSTABLE CURRENT SETTINGS. Ul Recognized File No. 62636 The Class 235 Current Sensing Relay combines a Solid State Sensor with a SPDT, 10 Amp relay. The Sensor is field adjustable for detecting AC Current levels in equipment. The sensor is non-latching and has no time delay. Choice of 1/4" or 3/16" Quick Connect terminals. 6-32 Tapped Hole & anti rotation Tab or Plug-in with 3/16" terminals. Optional. Polycarbonate dust cover. 4 oz. (113 g) approx. Mounting: Mounting Bracket: Enclosure: Weight: OUTLINE DIMENSIONS Dimensions are Shown In Inches and (Millimeters) WIRING DIAGRAM SUPPLY VOLTAGE 2.90 Max. (73.8) .312 (7.9) 1.53 (38.8) 1 2 3 4 5 6 1 4 2 5 3 6 7 8 9 7 8 9 .625 (15.8) 1.40 (35.7) LOAD B A A B INPUT 1.31 (33.3) Continuous Voltage must be supplied to Input. .875 (22.2) VIEWED FROM TERMINAL SIDE ANTI-ROTATION TAB SEE SECTION 10 FOR MATING SOCKETS 6-32 TAPPED HOLE (1/4" Terminal Style) PART NUMBERS NOMINAL INPUT VOLTAGE W235ACX-2 W235ACX-3 120 VAC 120 VAC CURRENT RANGE TERMINAL SIZE 1.5 to 15 Amps 1/4" (.250) 1.5 to 15 Amps 3/16" (.187) PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. NOTE: 3/16" (.187) TERMINALS ARE SOCKET MOUNTABLE. 1/4" (.250) TERMINALS, NO SOCKET AVAILABLE FOR THIS STYLE. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 132 SERIES OVER/UNDER VOLTAGE SENSING, 10 AMP, 2-4 POLE 349 SERIES 349 FREQUENCY 50 to 400 Hz PULL-IN ADJUSTABLE BETWEEN 85 to 135 VAC 10 AMP CONTACTS OUTLINE DIMENSIONS Dimensions shown are in INCHES and (millimeters) Differential 4.0 volts ± 1 Volt nonadjustable .313 (7.95) 1 7 RESISTOR 1 A CONTACT LOAD SPECIFICATIONS Make Carry Resistive Inductive Voltage 10A 10A 5A 10A 0.5A B C N RESISTOR 6 10A 3A 1A 3A 0.1A SENSING MODULE 12 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 1 6 12 7 1.468 (37.2) 7 THREE PHASE -349XBXP For Versions with suffix "69" Permanent Magnet Blowouts 125 VDC (SM) 125 VDC (DM) 250 VDC (SM) 250 VDC (DM) INPUT 7 1 10A 10A 10A 10A 10A 4.56 (115.8) 6 SINGLE PHASE -349ABXP 349 ABXP & XBXP Style the Differential Adjustment is Externally Adjustable from 3 to 14 Volts. 30A 30A 30A 30A 30A 3.75 (95.2) SINGLE PHASE -349BBXP 12 24 VDC 120 VAC 240 VAC 28 VDC 125 VDC INPUT SENSING MODULE 12 SENSING MODULE The Series 349 Under/Over Voltage Sensing Relay incorporates a Series 219 relay and an Electronic Module. Pull-in Voltage is adjustable between 85 and 135 VAC for frequencies from 50 to 400 Hz. Models available for Single and Three Phase sensing with differential (between pull-in and Dropout) Adjustable from 2 to 14 Volts by external fixed or adjustable resistor. Single Phase relays are also available with standard 3 volt fixed differential and other fixed values up to 14 volts, on special order. 6 0.5A 1.5A 150mA 0.5A 2.625 (66.6) Struthers-Dunn Typical Part Number 349 BBX Series 349 Sensor -Plug-in, Over/Under Voltage Relay, 10A, 2 -4 poles P L33- 85-135A GENERAL SPECIFICATIONS SERIES 349 SENSOR INPUT Module Voltage: AC Current Drain: CONTACTS Contact Material: Adjustment 85 to 135 VAC, 50 to 400 Hz De-energized -15 mA, Energized - 50 mA Silver Cadmium Oxide. - Gold Diffused OPERATIONAL CHARACTERISTICS 25 Milliseconds Operate time: 25 Milliseconds Release Time: INSULATION CHARACTERISTICS Dielectric Strength Across Open Contacts: All Mutually Insulated Points: Insulation Resistance 500 V rms 1500 V rms 1000 Megohms min. @ 500VDC. ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: -10˚C to +60˚C @ Rated Operation. LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: PAGE 133 20 Million Operations no load 100,000 Operations @ Rated Load. 500,000 @ 1/2 Rated Load. Clear polycarbonate 10 oz. (284 g) Contact Arrangement & Function BBX - 2 Form A & 2 Form C, (Single Phase) 4V ± 1V Fixed. ABX - 1 Form A & 2 Form C, (Single Phase) Ext. Adjustment, 3 to 14V XBX - 2 Form C, (3 Phase) External Adjustment, 3 to 14V Standard Features Plug-in With Polycarbonate Cover - Code P Options Indicator Lamp- Code L Manual Actuator - Code M Bifurcated Contacts (5 Amps max) - Code 33 Permanent Magnet, Blowout Code 69 Operating Voltage AC; 85 to 135 (Add "A" ) DC; Consult Factory Note: For non-Standard Differential Consult Factory SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 ADJUSTABLE VOLTAGE SENSING RELAY The Class 236 Voltage Sensing Relay combines a Solid State Sensor with a SPDT, 13 Amp or DPDT 10 Amp relay. The Sensor is field adjustable for Pull-in & Dropout . The 236 can be used either as a over or under voltage detecting relay. The sensor is non-latching and has no time delay. Applications: Brownout protection, warning of under voltage conditions and Over voltage protection. Prevents equipment burnout. CLASS 236 CLASS 236 VOLTAGE SENSOR Ul Recognized File No. 62636 SPECIFICATIONS CLASS 236 CURRENT SENSOR VOLTAGE SENSING: Nominal Input: ±1 % REPEATABILITY SPDT, 13 AMP CONTACTS FIELD ADJUSTABLE 120,240,480 VAC 50/60Hz, 24VAC, 24 VDC. Other AC & DC Voltages Available. Pull-in 75% to 115% of Nominal Voltage. Adjustment Range: Dropout 75% to 95% of Pickup setting. ± 1% @ constant Voltage & Temperature Repeatability: 15 mA (1.7 VA) Input Current: Relay "Off" 2 mA max. Relay "On" 22 mA max. @ 120AC (2.7 VA) Current Sensor Resistance: 12 mA 240AC max. (2.9VA), 7 mA max. 480 AC (3.41 VA) Temperature Range Operate: - 30˚C to + 55˚C Temperature Range Storage: - 40˚C to + 85˚C CONTACTS Contact Combinations: Contact Rating Contact Life Electrical: Contact Life Mechanical: Transient: Noise Immunity: SPDT (1 Form C), DPDT (2 Form "C") SPST: 13 Amps @ 240 VAC, 28 VDC Res. 1/3 HP @ 120 VAC, 1/2 HP @ 240/480 AC, 3 AMPS @ 480 VAC, NEMA B300 Pilot Duty DPDT: 10 AMPS @ 240 VAC/28 VDC Res. 1/3Hp @ 120 VAC, 1/2 Hp 240 VAC NEMA B300 Pilot Duty. SPDT: 100,000 Operations @ 13 Amps, 240AC Res. DPDT: 100,000 Operations @ 10 Amps, 240AC Res. SPDT:5,000,000 Operations DPDT: 50,000,000 Operations. UL 508 Surge 5000 V for 50 microseconds NEMA ICS2-230, 2500 VAC DIELECTRIC STRENGTH Breakdown: Coil to Contacts: Across Open Contacts: UL 508 Surge 5KV 1.2 x 50 Microseconds. 2500 V rms 1000 V rms MECHANICAL Terminals: Enclosure: Power "ON" Indicator: Weight: 3/16" (.187) Quick Connect terminals. or 8 Pin Octal base Polycarbonate dust cover. L.E.D. ( Green) 4 oz. 124.4 g, 5 oz 155.5g (8 pin octal) ±1 % REPEATABILITY DPDT, 10 AMP CONTACTS FIELD ADJUSTABLE SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 134 CLASS ADJUSTABLE VOLTAGE SENSING RELAY 236 OUTLINE DIMENSIONS Dimensions are Shown In Inches and (Millimeters) WIRING DIAGRAMS 2 3 4 5 6 7 8 1 4 2 5 3 6 7 8 9 L.E.D 1 2.90 Max. (73.8) .312 (7.9) 1.53 (38.8) VIEWED FROM PIN END FIGURE "B" 1.40 (35.7) 9 A B B A INPUT L.E.D L.E.D Dropout Pull-in SQUARE BASE Continuous Voltage must be supplied to Input. Screw Driver Adjustable with Graduated scale. OUTLINE DIMENSIONS Dimensions are Shown In Inches and (Millimeters) .562 (14.2) L.E.D WIRING DIAGRAMS VIEWED FROM PIN END FIGURE "A" ▼ ▲ 2.93 (74.4) ▼ ▲ 4 5 6 3 2 7 1 + 8 INPUT 2.37 (60.3) 8 PIN OCTAL Continuous Voltage must be supplied to Input. 7 6 5 8 4 1 3 PART NUMBERS FIG. W236ACX-1 W236ACX-2 W236ACX-4 B B B W236ACPX-1 W236ACPX-4 W236CPX-1 A A A NOMINAL INPUT VOLTAGE VOLTAGE PULL-IN RANGE VOLTAGE DROP-OUT RANGE 120 VAC 90 to 138 VAC 75% to 95% 208/220 240 VAC 180 to 276 VAC of Pickup Voltage 480 VAC 360 to 552 VAC Setting 120 VAC 24 VAC 24 VDC 92 to 140 VAC 90 to 138 VAC 20 to 30 VAC 18 to 28VAC 20 to 30 VDC 18 to 28 VDC 1.75 (44.4) 2 CROSS REFERENCE TO POTTER & BRUMFIELD CSJ-38-70010 CSJ-38-30010 CSL-38-30010 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PAGE 135 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 S E C T I O N 6 6 POWER RELAYS AND CONTACTORS 15 TO 200 AMPERES Page 136 Magnecraft Struthers-Dunn POWER RELAYS & CONTACTORS RELAY SERIES 199 425 88UKD 415 QUALIFIED FEATURES PANEL MOUNT, OPEN STYLE CONSTRUCTION MULTI CONTACT CONFIGURATIONS UP TO 50 AMPS SWITCHING. MAGNETIC BLOWOUT FOR DC SWITCHING COMPACT OPEN STYLE PANEL MOUNT OPEN STYLE CONSTRUCTION RELAY WITH 6-32 TAPPED HOLE & ANTI-ROTATION 3PDT CONTACT TAB FOR PANEL MOUNT. CONFIGURATIONS UP TO 30 AMP SWITCH- SWITCHES UP TO 3O ING AMPS SCREW TERMINALS PANEL MOUNT, COMPACT SIZE, OPEN STYLE CONSTRUCTION. MULTI CONTACT CONFIGURATIONS. SCREW TERMINALS. 1/4" SPADE LUG TERMIINSULATED ARMATURE NALS TO 600V AVAILABLE DOUBLE MAKE CONTACTS OPTIONAL HIGH VOLTAGE AND HIGH INRUSH CONTACTS, Q.C. TERMINALS, MAGNET BLOWOUT. SPECIAL LOW POWER COILS AVAILABLE. SEE CATALOG PAGE 30 AMPS UP TO 300 VAC, 28 VDC, (STD.) BOX TERMINAL SPST-DM -UP TO 50A. WITH MAGNETIC BLOWOUT UP TO 20AMP DC 3PDT 25 AMP @120-240VAC 17AMP @ 277VAC 10AMP @ 600VAC 30AMP @ 30VDC SPST-N.0. (DM) SEE CATALOG PAGE 15 AMPS @ 120VAC 1/2HP 10 AMPS @ 240VAC 1HP 15 AMPS @ 30VDC CONTACT MATERIAL: SILVER CADMIUM OXIDE, SILVER CADMIUM OXIDE CONTACT RESISTANCE: 50 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) SILVER ALLOY GOLD FLASHED 50 MILLIOHMS (INITIAL) 2200 V rms 2500 V rms CLASS "B" INSULATION SYSTEM SCREW & BOX TERMINALS CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: 30 AMPS @ 300VAC/28VDC 5 AMPS 600VAC SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH 3000 V rms 1500 V rms COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER VA,: (VAC) WATTS,: (VDC) 24, 120 & 240 VAC 6, 12, 24, 110 VDC 6 to 480 VAC 6 to 220 VDC 24, 120 & 240 VAC 12, 24 & 110 VDC 10 VA 2.0 WATTS 11 VA 4.0 WATTS 3 VA 1.5 WATTS STORAGE: TIMING VALUES OPERATE: RELEASE: - 30˚ C to + 50˚ C (AC.) - 30˚ C to + 60˚ C (DC) - 30˚ C to + 100˚ C 40 MILLISECONDS 35 MILLISECONDS - 55˚ C to + 45˚ C (AC) - 55˚ C to + 80˚ C (DC) LIFE MECHANICAL: ELECTRICAL: 5 MILLION OPERATIONS 100,000 OPERATIONS 10 MILLION OPERATIONS 100,000 OPERATIONS 6 to 240 VAC 6 to 125 VDC (Use power resistor for 250VDC) 6VA 3.5 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: DIMENSIONS D W L 2.53 X 2.50 X 2.43-3.12 - 10˚ C to + 50˚ C (AC) - 10˚ C to + 60˚ C (DC) 25 MILLISECONDS 10 MILLISECONDS 30 MILLISECONDS 15 MILLISECONDS D W L 2.30 X 2.50 X 3.24 - 45˚ C to + 55˚ C - 45˚ C to + 55˚ C 5 MILLION OPERATIONS 100,000 OPERATIONS D W L .1.40 X 1.25 X 1.93 AC- 50M, - DC-100M OPER'S. 200,000 OPERATIONS D W L 1.75 X 1.87 X 2.75 APPROVALS PAGE NUMBER PAGE 137 PAGE 140 THRU 146 PAGE 147 PAGE 148 PAGE 149, 150 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 Magnecraft Struthers-Dunn CONTACTORS 103 275 575 2 COIL, COMPACT MOTOR REVERSING CONTACTOR. 2 COIL, MOTOR REVERSING CONTACTOR 1/4" DUAL Q.C. TERMINALS WITH UP TO 4 OPTIONAL AUXILIARY SWITCHES. MECHANICAL INTERLOCK CHOICE OF CONTACT CONFIGURATIONS COILS CHOICE OF CONTACT CONFIGURATIONS CHOICE OF CONTACT CONFIGURATIONS RATED UP TO 50 AMPS SCREW TERMINALS WITH CONTINUOUS OPTIONAL 5A AUXILIARY CONTACTS ENCLOSED SWITCHES AVAILABLE. WITH MOLDED PLASTIC COVER. RATED UP TO 7.5 HP RATED UP TO 100 AMPS CONTINUOUS RATED UP TO 200 AMPS CONTINUOUS CONTACTS ENCLOSED WITH MOLDED PLASTIC COVER. CONTACTS ENCLOSED WITH MOLDED PLASTIC COVER. AC COILS AVAILABLE AC COILS AVAILABLE ENCAPSULATED COIL USED FOR AC OR DC MODELS MECHANICAL INTERLOCK, CENTER OFF WHEN BOTH COILS NOT ENERGIZED. 6 POLE-DM (3 PER COIL) 15 AMPS @120VAC/1HP 10AMPS @ 240VAC/1.5HP 5AMPS @ 480/600/3HP 15AMPS @ 30VDC 5AMPS @ 125VDC 1AMP @ 250VDC 102 101 HEAVY DUTY DC SOLENOID HEAVY DUTY DC SOLENOID STYLE CONTACTOR. STYLE CONTACTOR. AC COILS AVAILABLE 6 POLE-DM (3 PER COIL) 30 AMPS @120 VAC, 1.5HP 30 AMPS @240VAC, 3HP 15 AMPS @480 VAC, 7.5HP 15 AMPS @600 VAC, 7.5HP 15 AMPS @ 115VDC 2 AMPS @ 230 VDC SEE CATALOG PAGE 50 AMPS @ 120/240VAC, 30 VDC SEE CATALOG PAGE HEAVY DUTY DC SOLENOID STYLE CONTACTOR. SEE CATALOG PAGE 200 AMPS @ 120/240VAC, 30 VDC 100 AMPS @ 120/240VAC, 30 VDC SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE 100 MILLIOHMS (INITIAL) 100 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) 2500 V rms 2500 V rms 1500 V rms 12 to 240 VAC 12 to 120 VDC 24 to 550VAC 12 to 240 VDC 12, 28, 48 VDC 12, 28, 48 VDC 12, 28, 48 VDC 16.7 VA 4.9 WATTS 22 VA 10 WATTS 9 WATTS 11.6 WATTS 14 WATTS - 45˚ C to + 50˚ C (AC) - 45˚ C to + 70˚ C (DC) - 40˚ C to + 50˚ C (AC) - 40˚ C to + 50˚ C (DC) - 45˚ C to + 65˚ C (DC) 50 MILLISECONDS 30 MILLISECONDS 60 MILLISECONDS 30 MILLISECONDS 500,000 OPERATIONS 100,000 OPERATIONS 500,000 OPERATIONS 100,000 OPERATIONS D W L D W L 2.75 X 2.985 6 X 3.62 3.00 X 5.25 X 4.43 PAGE 151, 152 PAGES 153, 154 1500 V rms 1500 V rms - 45˚ C to + 65˚ C (DC) - 45˚ C to + 65˚ C (DC) 60 MILLISECONDS 30 MILLISECONDS 60 MILLISECONDS 30 MILLISECONDS 60 MILLISECONDS 30 MILLISECONDS 500,000 OPERATIONS 100,000 OPERATIONS 500,000 OPERATIONS 100,000 OPERATIONS 500,000 OPERATIONS 100,000 OPERATIONS D W L 1.84 X 2.34 X 2.50 PAGES 155, 156 D W L D W L 2.09 X 3.12 X 3.00 2.65 X 4.25 X 3.00 PAGES 155, 156 PAGES 155, 156 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 138 Magnecraft Struthers-Dunn POWER , GFI AND MDR RELAYS RELAY SERIES FEATURES 214 (GFI) SMALL OPEN STYLE GROUND FAULT INTERRUPT RELAY. MAX. OVER LOAD 120 AMPS @ 120VAC 102, 103 MDR MERCURY DISPLACEMENT RELAY (MDR) UP TO 3 POLES, NO OR NC & COMBINATIONS OF NO & NC ENCAPSULATED COIL.. PIERCED SOLDER LUG TERMINALS WITH #17 AWG SILICONE WIRE UP TO 100 AMPS SWITCHING MOUNTING WITH 6-32 TAPPED HOLE & ANTIROTATION TAB PANEL MOUNTED VERTICAL ± 15˚ LOW CONTACT RESISTANCE HEAVY DUTY DC SOLENOID STYLE LIGHTING CONTACTOR, MOUNTS TO WATT HOUR METER ENCLOSURE. DPST-NO-DM CONTACT CONFIGURATION. RATED UP TO 50 & 100 AMPS CONTINUOUS DUTY. CONTACTS ENCLOSED IN MOLDED PLASTIC COVER. DC COILS AND AC FULL WAVE RECTIFIED COILS. CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT CONTACT MATERIAL: RESISTANCE: DPDT (2 FORM C) 20 AMPS @ 120/240VAC 20 AMPS @ 30 VDC 120AMPS @ 120VAC (10 CYCLES) SILVER, CADMIUM OXIDE 50 MILLIOHMS (INITIAL) 1 to 3PST-NO or NC 35 TO 100 AMPS @ 120-480VAC. 25-50 AMPS @ 600VAC 100 AMPS, 24-48 VDC 80 AMPS, 120VDC MERCURY DPST-NO-DM 50 & 100 AMPS @ 120/240VAC, 30 VDC SILVER CADMIUM OXIDE 2 MILLIOHMS 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: 2000 V rms 2650 V rms 1500 V rms COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER VA, (VAC): WATTS, (VDC): 6, 12, 24, 120 VAC 6, 12, 24, 110-125 VDC - 12 to 240 VAC 6 to 220 VDC 120 & 240 VAC 24 VDC 20 WATTS 33 VA 9 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: DIMENSIONS - 45˚ C to + 65˚ C - 35˚ C to + 60˚ C 15 MILLISECONDS 15 MILLISECONDS 50 MILLISECONDS 100 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS 5 MILLION OPERATIONS 100,000 OPERATIONS - 45˚ C to + 65˚ C (DC) D W L 1.37 X 1.00 X 2.10 D W L 3.36 X 3.75 X 5.06 60 MILLISECONDS 30 MILLISECONDS 500,000 OPERATIONS 100,000 OPERATIONS D W L 3.0 X 6.0 X 6.0 APPROVALS GENERAL SPECIFICATIONS & APPLICATION DATA: PAGE NUMBER PAGE 139 PAGE 157 PAGE 158, 159 PAGE 160 THRU 164 PAGES 165 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 OPEN STYLE 30 AMP POWER RELAY CLASS 199 CLASS 199 SPDT UL Listed File No. E43641 * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE 30 AMP - 1-1/2 Hp CLASS "B" COIL INSULATION SYSTEM IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeters) 2.18 Max. (55.37) UP VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP .375 (9.5) 2.50 (63.5) 1.87 (47.5) 0.187 Dia. (2 Places) 1.62 41.14 2.43 Max. (61.7) SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combination: Contact Rating Contact Material: TIMING Operate time: Release Time: DIELECTRIC STRENGTH Between Open Contacts: Mutually Insulated Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material: Weight: 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25˚C 10% of Nominal Voltage or More @ 25˚C ± 10% @ 25˚C DC Coils-4 Watts Max. Continuous. SPDT 30 Amps up to 300VAC, 50/60Hz 5 Amps @ 480/600 VAC, 50/60HZ 0.75pF Inductive Load. 1-1/2 HP Motor Load @ 120 thru 600 VAC, 50/60 Hz. 30 Amps @ 28 VDC Resistive Load NEMA A 600 Pilot Duty 50/60Hz * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V 1500 V rms 2200 V rms PART NUMBERS (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C -30˚C to +100˚C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 8 oz. - 227 Grams approx. (SPDT) COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL RESISPOWER INPUT TANCE VOLTAGE (OHMS) AC OPERATED (SPDT) 120 VAC W199AX-4 DC OPERATED (SPDT) 12 VDC W199X-2 24 VDC W199X-3 CROSS REFERENCE POTTER & BRUMFIELD - 10 VA PRD5AGO-120 70 290 2.0 W 2.0 W PRD5DGO-12 PRD5DGO-24 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 140 CLASS OPEN STYLE 30 AMP POWER RELAY 199 CLASS 199 DPDT 30 AMP - 1-1/2 Hp CLASS "B" COIL INSULATION SYSTEM UL Listed File No. E43641 * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeters) 2.31 Max. (58.67) UP 2.50 (63.5) 1.87 (47.5) 0.187 Dia. (2 Places) .375 (9.5) COIL Pull-in Voltage: AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES COIL Measured @ 25˚C CROSS NOMINAL NOMINAL NOMINAL REFERENCE RESIS- POWER INPUT POTTER & TANCE VOLTAGE BRUMFIELD (OHMS) AC OPERATED (DPDT) 24 VAC W199AX-13 120 VAC W199AX-14 240 VAC, 60 Hz W199AX-15 220 VAC, 50 Hz - 10 VA 10 VA - 10 VA PRD11AGO-24 PRD11AGO-120 PRD11AGO-240 DC OPERATED (DPDT) W199X-11 W199X-12 W199X-13 W199X-14 6 VDC 12 VDC 24 VDC 110 VDC 18 70 290 6000 2.0 W 2.0 W 2.0 W 2.0 W PRD11DGO-6 PRD11DGO-12 PRD11DGO-24 PRD11DGO-110 RECTIFIED, AC OPERATED (DPDT) W199AXD-38 ✝ 208, 240, 277 VAC - See Note ✝✝ PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. ✝ ✝✝ Built in Coil Diodes provide a wide range of Nominal Coil input voltages. This relay is suitable to Operate within a range of 208 Vac thru 277 Vac. 208 Vac = 2.3 VA, 240 Vac = 3.0 VA, 277 Vac = 4.0 VA. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. Dropout Voltage: Coil Resistance: Max. Coil Dissipation: 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25˚C 10% of Nominal Voltage or More @ 25˚C ± 10% @ 25˚C DC Coils-4 Watts Max. Continuous. CONTACTS DPDT Contact Combinations: Contact Rating each Pole: 30 Amps up to 300VAC, 50/60Hz 5 Amps @ 480/600 VAC 50/60Hz, 0.75pF Inductive Load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two poles to switch both sides of Load. 30 Amps @ 28 VDC Resistive Each Pole. NEMA A600 Pilot Duty 50/60HZ Contact Material: TIMING Operate time Release Time: Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated 2200 V rms Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C LIFE Electrical (Rated Load): Mechanical (No Load): 100,000 Operations 5,000,000 Operations MISCELLANEOUS Coil Terminals: l Contact Terminals: Base Material: Weight: PAGE 141 VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP SPECIFICATIONS CLASS 199 * RELEVANT IEC CONTACT UTILIZATION CATEGORIES PART NUMBERS 1.62 3.12 (41.1) (79.2) -30˚C to +100˚C 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 11 oz. - 311 Grams approx. (DPDT) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS OPEN STYLE POWER RELAY 199 CLASS 199 DPST-NO UL Listed File No. E43641 * 1-1/2 HP PER POLE 2 Hp - 2 POLE SWITCHING CLASS "B" COIL INSULATION SYSTEM COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeters) 2.25 Max. (57.15) UP .375 (9.5) 2.50 (63.5) VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP 1.87 (47.5 0.187 Dia. (2 Places) 1.62 41.14 2.43 Max. (61.7) SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25˚C 10% of Nominal Voltage or More @ 25˚C ± 10% Measured @ 25˚C DC Coils-4 Watts Max. Continuous. CONTACTS Contact Combinations: DPST-NO Contact Rating each Pole: Each pole rated 30 Amps up to 300 VAC, 50/60Hz, 5 Amps @ 480/600VAC ,0.75pF Inductive load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two pole to switch both sides of Load 30 Amps @ 28 VDC Resistive load each Pole. NEMA A600 Pilot Duty 50/60Hz Contact Material: TIMING Operate time Release Time: COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL RESISPOWER INPUT TANCE VOLTAGE (OHMS) PART NUMBERS 40 Milliseconds Max. @ Nominal V 35 Milliseconds Max. @ Nominal V AC OPERATED (DPST-NO) DPST-NO W199AX-8 24 VAC W199AX-9 120 VAC W199AX-10 240 VAC, 60 Hz 220 VAC, 50 Hz - 10 VA 10 VA - 10 VA CROSS REFERENCE POTTER & BRUMFIELD PRD7AGO-24 PRD7AGO-120 PRD7AGO-240 DC OPERATED (DPST-NO) TEMPERATURE Operating Range: Non-Operating Storage range: (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C LIFE Electrical (Rated Load): Mechanical (No Load): 100,000 Operations 5,000,000 Operations Weight: AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated Conductive elements: 2200 V rms MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material: * RELEVANT IEC CONTACT UTILIZATION CATEGORIES -30˚C to +100˚C W199X-7 W199X-8 12 VDC 24 VDC 70 290 2.0 W 2.0 W PRD7DGO-12 PRD7DGO-24 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 9 oz. - 255 Grams approx... (DPST-NO) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 142 C L A SS OPEN STYLE POWER RELAY 199 CLASS 199DB SPST-NO-DM WITH UL Listed MAGNETIC BLOWOUT File No. E43641 FOR DC ARC QUENCING * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeters) MAGNETIC Blowout 2.18 Max. (55.4) 2.50 (63.5) UP .375 (9.5) 1.87 (47.5) 0.187 Dia. (2 Places) VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP 1.62 41.14 2.43 Max. (61.7) 0.10 (2.54) SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: Contact Rating : Additional Ratings, with Blowout Magnet for DC switching: Contact Material: 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25˚C 10% of Nominal Voltage or More @ 25˚C ± 10% Measured @ 25˚C DC Coils-4 Watts Max. Continuous. SPST-NO-DM Double Make 30 Amps up to 300 VAC, 50/60Hz, 5 Amps @ 480/600Vac,0.75pFInductive Load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two poles to switch . 30 Amps @ 28 VDC Resistive Each Pole. NEMA A600 Pilot Duty 50/60Hz 20 Amps @ 110 VDC, Resistive; 8 Amps at 220 VDC, Resistive, 4 Amps @ 325VDC Resistive. 2 amps @ 500 VDC resistive. For Inductive Loads, contacts must be derated accordingly. Capacitive loads must be limited to insure that inrush current will not exceed 100 Amps. TIMING Operate time: Release Time: 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated Conductive elements: 2200 V rms TEMPERATURE Operating Range: Non-Operating Storage range: (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C -30˚C to +100˚C LIFE Electrical (Rated Load): Mechanical (No Load): 100,000 Operations 5,000,000 Operations MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material: Weight: 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 8 oz. - 227 Grams approx. (SPST-NO-DM) Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES COIL Measured @ 25˚C CROSS NOMINAL NOMINAL NOMINAL REFERENCE RESISPOWER POTTER & INPUT BRUMFIELD VOLTAGE TANCE (OHMS) AC OPERATED (SPST-NO-DM WITH MAGNETIC BLOWOUT) PART NUMBER W199ADBX-4 120 VAC - 10 VA PRD3AJ0-120 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. PAGE 143 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 DOUBLE MAKE OR BREAK POWER RELAYS UL Listed File No. E43641 199 CLASS 199 SPST-NC-DB OR SPST-NO-DM COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE * CLASS RATED 30 AMPS @ 2 HP CLASS "B" COIL INSULATION SYSTEM IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeters) 2.25 Max. (57.15) 1.87 2.50 (47.5) (63.5) 0.187 Dia. (2 Places) SPST-NC-DB UP .375 (9.5) VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP 1.62 41.14 2.43 Max. (61.7) 0.10 (2.54) SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: 80% DC Coils, 85% AC coils of nominal voltage or Less. @ 25˚C 10% of Nominal Voltage or More @ 25˚C ± 10% @ 25˚C DC Coils-4 Watts Max. Continuous. SPST-NC (Double Break SPST-NO (Double Make Contact Rating SPST-NO-DM: 30 Amps up to 300 VAC, 50/60Hz 12 Amps @ 480, 10 Amps @ 600VAC,50/60 0.75pFInductive Load. 2 HP Motor Load @ 120 thru 600 VAC, 50/60 Hz. 30 Amps @ 28 VDC Resistive load. NEMA A600 Pilot Duty 50/60Hz :Contact Material: Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. TIMING Operate time Release Time: 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V DIELECTRIC STRENGTH Between Open Contacts: Mutually Insulated Conductive elements: 1500 V rms TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contacts Terminals: Base Material: Weight: 2200 V rms (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C -30˚C to +100˚C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL recognized (QMz2) 8 oz. - 227 Grams approx. SPST-NO-DM * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES COIL Measured @ 25˚C CROSS NOMINAL NOMINAL REFERENCE RESISPOTTER & POWER TANCE BRUMFIELD (OHMS) DC OPERATED (SPST-NC-DB WITH 30 AMP SCREW TERMINALS) PRD4DG0-12 70 2.0 W W199DYX-2 12 VDC AC OPERATED (SPST-NO-DM WITH 30 AMP SCREW TERMINALS) PART NUMBERS NOMINAL INPUT VOLTAGE W199ADX-4 120 VAC W199ADX-5 240 VAC, 60 Hz 220 VAC, 50 Hz - 10 VA - 10 VA PRD3AG0-120 PRD3AG0-240 DC OPERATED (SPST-NO-DM WITH 30 AMP SCREW TERMINALS) W199DX-2 W199DX-3 12 VDC 24 VDC 70 290 2.0 W 2.0 W PRD3DG0-12 PRD3DG0-24 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 144 CLASS DOUBLE MAKE POWER RELAYS 199 CLASS 199 SPST-NO-DM RATED 50 AMPS - 2HP WITH BOX TERMINALS. CLASS "B" COIL INSULATION SYSTEM S BO HOW X T NW I ER MIN TH AL S UL Listed File No. E43641 * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION OUTLINE DIMENSIONS Dimensions shown in Inch & (Millimeters) 50 AMP BOX TERMINALS ACCEPT NO.14 THRU NO. 6 AWG. WIRE Box Terminal's 2.18 Max. (55.4) .375 (9.5) UP 2.50 (63.5) 1.87 (47.5) 1.62 41.14 VERTICAL MOUNTING 2.43 Max. (61.7) 3.50 Max. (88.9) 0.187 Dia. (2 Places) 0.10 (2.54) RECOMMENDED WITH CONTACTS UP SPECIFICATIONS CLASS 199 COIL Pull-in Voltage: * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES COIL Measured @ 25˚C CROSS NOMINAL NOMINAL NOMINAL REFERENCE RESISPOTTER & INPUT POWER TANCE BRUMFIELD VOLTAGE (OHMS) AC OPERATED (SPST-NO-DM WITH 50 AMP BOX TERMINALS) PART NUMBERS W199ADEX-4 120 VAC - 10 VA PRD3AP4-120 Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: 80% DC Coils, 85% AC coils of nominal voltage or Less. @ 25˚C 10% of Nominal Voltage or More @ 25˚C ± 10% @ 25˚C DC Coils-4 Watts Max. Continuous. SPST-NO Double Make Contact Ratings : 50 Amps up to 300 VAC, 50/60Hz 50 Amps @ 28 VDC Resistive load. Loads must be current limited as not to exceed 100 Amp inrush Currents. NEMA A600 Pilot Duty 50/60Hz Contact Material: Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. TIMING Operate time Release Time: 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V DC OPERATED (SPST-NO-DM WITH 50 AMP BOX TERMINALS) W199DEX-3 24 VDC 290 2.0 W PRD3DP4-24 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. DIELECTRIC STRENGTH Between Open Contacts: Mutually Insulated Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: LIFE Electrical (Rated Load): Mechanical (No Load): MISCELLANEOUS Coil Terminals: Contacts Terminals: Base Material: Weight: PAGE 145 1500 V rms 2200 V rms (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C -30˚C to +100˚C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 8 oz. - 227 Grams approx. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS DC SWITCHING POWER RELAY 199 CLASS 199B UL Listed File No. E43641 * COMPLIES WITH REQUIREMENTS OF IEC STANDARDS 947-4-1 AND 947-5-1 LOW VOLTAGE DIRECTIVE IEC = INTERNATIONAL * ELECTROTECHNICAL COMMISSION DPDT WITH MAGNETIC BLOWOUT FOR DC ARC QUENCHING 10 AMP @ 110 VDC CLASS "B" COIL INSULATION SYSTEM OUTLINE DIMENSIONS COIL Pull-in Voltage: Dropout Voltage: Coil Resistance: Max. Coil Dissipation: CONTACTS Contact Combinations: Contact Rating : 80% DC Coils, 85% AC coils of nominal voltage or Less @ 25˚C 10% of Nominal Voltage or More ™ 25˚C ± 10% @ 25˚C DC Coils-4 Watts Max. Continuous. 2.53 Max. (64.3) DPDT 30 Amps up to 300 VAC, 50/60Hz 5 Amps @ 480/600VAC ,0.75pFInductive Load. 1-1/2 HP Motor Load (each Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz only when using two poles to switch both sides of Load 30 Amps @ 28 VDC Resistive Each Pole. NEMA A600 Pilot Duty 50/60 Hz DC Ratings: 10 Amps @ 110 VDC, Resistive; 4 Amps at 220 VDC, Resistive, 2 Amps @ 325VDC Resistive. For inductive Loads, contacts must be derated accordingly. Capacitive loads must have current limiting to insure that inrush current will not exceed 50 Amps Contact Material: Silver Cadmium Oxide, Gold Flashed. 5/16" Diameter Standard. TIMING Operate time: Release Time: MAGNETIC BLOW OUT SPECIFICATIONS CLASS 199 MAGNETIC BLOW OUT Dimensions shown in Inch & (Millimeters) 40 Milliseconds Max. @ Nominal V 30 Milliseconds Max. @ Nominal V 2.50 (63.5) 1.87 (47.5 0.187 Dia. (2 Places) LIFE Electrical (Rated Load) Mechanical (No Load) MISCELLANEOUS Coil Terminals: Contact Terminals: Base Material Weight: (AC) -30˚C to +50˚C, (DC) -30˚C +60˚C -30˚C to +100˚C 100,000 Operations 5,000,000 Operations 6-32 Binder Head Screws 8-32 Binder Head Screws Molded Phenolic, UL Recognized (QMFZ2) 11 oz. - 312 Grams approx.. (DPDT) 1.62 (41.14) UP VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP * RELEVANT IEC CONTACT UTILIZATION CATEGORIES AC-1, AC-3, DC-1, AC-15 SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES DIELECTRIC STRENGTH Between Open Contacts: 1500 V rms Mutually Insulated 2200 V rms Conductive elements: TEMPERATURE Operating Range: Non-Operating Storage range: .375 (9.5) 3.12 (79.24 PART NUMBERS COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL RESIS- POWER INPUT TANCE VOLTAGE (OHMS) CROSS REFERENCE POTTER & BRUMFIELD AC OPERATED (DPDT WITH BLOW OUT MAGNET) PRD11AJ0-120 10 VA W199ABX-14 120 VAC DC OPERATED (DPDT WITH BLOW OUT MAGNET) W199BX-14 110 VDC 6000 2.0 W PRD11DJ0-110 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR SPECIAL REQUIREMENTS. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 146 SERIES OPEN STYLE - 3 POLE, 30 AMP POWER RELAY 425 The series 425 Power relay is capable of handling up to 30 Amps and 1 Hp Loads. The Series 425 has sufficient spacing to allow for 600 Vac contact ratings . The Design features a enclosed coil, Screw Terminals and Silver Cadmium Oxide contacts as standard. The Series 425 has a wide choice of options to choose from. OUTLINE DIMENSIONS Dimensions shown are in INCHES and (millimeters) 3PDT 3.24 (82.3) CONTACT LOAD RATINGS 3 POLE RELAYS Load 30/DC 120-240/AC 208-240/AC 277/AC 600/AC General Duty 30A 17A 10A 25A 25A 1Ø 1HP◊ Motor (45% PF) 1Ø 1HP◊ 3Ø 3HP ◊ PER POLE 0.20 Dia.Typ. COIL SPECIFICATIONS 3 POLE RELAYS @ 25˚C Nominal Voltage 12 24 48 120 * 240 ** 480 Resistance Ohms ± 10% AC 1.8 6.7 27 170 680 2720 Resistance Ohms ± 10% DC 35.5 142 568 2980 - Current (MA) Power Consumption AC AC DC DC 11VA 4.0W 1600 333 11VA 4.0W 820 169 11VA 4.0W 410 84 85 18-21 11VA 4.0W 11VA 43 11VA 22 - 2.50 (63.5) 1.675 (42.5) 1.875 (47.6) UP VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP * AC Coil is 120V, 50/60Hz, DC Coil is 110-125VD ** For 220 VDC use 3600 Ω, 10 Watt resistor in series with 110 VDC relay. 1, 2, and 3 Pole Relays Min. Operate: AC: 85% of nominal Voltage or less @ 25˚C DC: 75% of nominal Voltage or less @ 25˚C Max. Over Voltage: 110% of nominal Struthers-Dunn ORDERING CODE Typical Type No. 425 XCX ULRecognized File No. E13224 -120A Series 425 Screw Terminal, 30A, 1-3 Pole Contact Arrangements Insulated Armature Types (600V) CXX 3PST-NO XCX 3PDT Options Tungsten Contacts (High Inrush) - CODE W 0.25 inch quick connect terminals- CODE 18 1 Aux. Contact (SPDT Snap Switch, 10A ) - CODE 90 2 Aux. Contact (SPDT Snap Switches, 10A ) - CODE 91 Coil Voltage AC: 6, 12, 24, 48, 120, 240, 480 (Add "A") DC: 6, 12, 24, 48, 110 -125 (Add "D") PAGE 147 GENERAL SPECIFICATIONS CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 30 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage. INSULATION CHARACTERISTICS Dielectric Strength 2500 V rms between Mutually insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. ENVIRONMENTAL CAPABILITIES Ambient Temperature Rating: AC: -55˚C to +45˚C @ Rated Operation. DC: -55˚C to +80 ˚C LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: 10 Million Operations no load 100,000 Operations @ Rated Load. Open Style Small Base 9oz. large base 11 oz.approx. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 OPEN STYLE 30 AMP POWER RELAY CLASS 88UKD CLASS 88UKD RELAY SIDE COIL SOLDER TERMINALS UL Recognized File No. E43641 SPST-N.O. DM, RATED 30 AMPS 1/4"QUICK CONNECT /SOLDER TERMINALS SWITCHES UP TO 1 HP AT 600 VAC 1.25Max. (31.7) 1.937. (49.1) 1.406 (35.7) .250 (6.35) .078 (1.98) .062 (1.57) .437 (11.1) .156 (3.9) 6-32 tapped mt. hole x .312 deep SPECIFICATIONS 88UKD COIL Pull-in Voltage (AC): Pull-in Voltage (DC): Dropout Voltage: Max. allowed voltage Coil Resistance: 85% of Nominal Voltage or less 80% of Nominal Voltage or less 10% of nominal voltage or more 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Contact Resistance: 1/4' silver alloy, gold flashed. Initial 50 Milliohms @ rated current. TEMPERATURE Operating: VIBRATION RESISTANCE Functional: 5g's 10 to 55Hz. 30 Amps up to 300VAC/28VDC, Resistive Load 5 Amps @ 600VAC Resistive.Load 1 HP @ 120-600 VAC Motor load. Contact Rating: TIMING Operate Time: Release Time: 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Contacts to frame: Insulation Resistance: 3000 V rms 1000 V rms 3000 V rms 1000 megohms min. @ 500 VDC SHOCK RESISTANCE Functional: 5g's 11mS Max. LIFE EXPECTANCY Mechanical: Electrical: 5 Million Operations 100,000 Operations @ Rated Load. MISCELLANEOUS Contact Insulation: Style: Mounting: Weight: Coil Measured @ 25˚C PART NUMBERS NOMINAL INPUT VOLTAGE AC OPERATED COIL 24VAC 120VAC 240VAC,60Hz 220VAC,50Hz DC OPERATED COIL 12 VDC W88UKDX-2 24 VDC W88UKDX-3 110 VDC W88UKDX-4 W88UKADX-3 W88UKADX-4 W88UKADX-5 -10˚C to +50˚C @ Rated Operation. (AC ) -10˚C to +60˚C @ Rated Operation. (DC ) NOMINAL NOMINAL RESISTANCE POWER (OHMS) - 3VA 3VA - 3VA 100 400 8000 1.5W 1.5W 1.5W Movable & stationary contacts are mounted on a molded plastic barrier insulator. Open style construction. 6-32 tapped hole and locating tab. 85 Grams, 3 oz. approx. CROSS REFERENCE TO POTTER & BRUMFIELD KR-3AH-24 KR-3AH-120 KR-3AH-240 KR-3DH-12 KR-3DH-24 KR-3DH-110 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 148 SERIES SCREW TERMINAL 15 AMP, 1 AND 2 POLE POWER RELAY 415 R Listed (XBX Only) file No. E13224 The Series 415 is a compact, 15 amp base mounted industrial relay. It is a versatile relay that offers a variety of contact configurations and options. Excellent contact life assures long mechanical life and contact reliability on low level loads. Screw terminals are standard. Options include: high voltage or high inrush contacts, quick connect terminals, permanent magnet blowout and low power DC coils. OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeters) 1.87 (47.4) 1.50 (38.1) 2.75 (69.85) 2.35 (59.69) 4 mtg.holes 0.181 ± .005 Dia. MAXIMUM DEPTH DIMENSION OF CONTACTOR 1.75", (44.45) UP VERTICAL MOUNTING RECOMMENDED WITH CONTACTS UP WIRING DIAGRAMS TOP VIEW Struthers-Dunn ORDERING CODE Typical Type No. 415 XBX 18 415XAX 415BXX 415XBX 415HXX -120A Series 415 Screw Terminals, 15 Amp 1 and 2 pole Contact Arrangements BXX (DPST-NO. HXX (SPST-NO-DM XAX (SPDT) XBX (DPDT) XHX (SPDT-DB-DM XXH (SPST-NC-DB Options 0.25 inch quick connect terminals - CODE 18 Permanent Magnet Blowout - CODE 69 (Consult Factory for other options) Coil Voltage AC: 6, 12, 24, 48, 120, 240, (Add "A") DC: 6, 12, 24, 32, 48, 115-125 (Add "D") 415XXH 415XHX Special coils: Low Power (mW), series coils. High Inrush contacts: 10 Amps continuous, 150 Amp Inrush. High Voltage Contacts: Up to 4KV PAGE 149 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SCREW TERMINAL 15 AMP, 1 AND 2 POLE POWER RELAY RESISTIVE MOTOR (80% pF) 415 CROSS REFERENCE STRUTHERS-DUNN TO WARD LEONARD CONTACT RATINGS LOAD SERIES 30/VDC 120VAC 240VAC 15A - 15A 1/2HP 10A 1HP AC COIL SPECIFICATIONS @ 25˚C (6VA) mA @ nominal voltage Nominal Voltage Resistance Inrush Sealed (60HZ) Ohms ± 10% Current Coil 6 1000 1.5 1800 12 500 6.3 900 250 24 25 450 48 125 100 225 120 50 620 90 240 25 2500 45 DC COIL SPECIFICATIONS @ 25˚C (3.5W) Nominal Voltage Resistance mA @ nominal voltage Coils Coils (VDC) Ohms ± 10% Cold Hot 6 500 10 600 12 250 40 300 24 125 155 150 32 95 390 112 48 62 620 75 *115/125 26 4000 31 * 220-250 VDC relays supplied with resistor in series with 115/125 VDC coil. STRUTHERS-DUNN WARD LEONARD DC COIL 2 POLE N.O. 415BXX-6D 105-1420 415BXX-12D 105-3420 415BXX-24D 105-4420 415BXX-110D 105-6420 DC COIL 2 POLE N.C.. 415XXB-6D 105-1421 415XXB-12D 105-3421 415XXB-24D 105-4421 415XXB-110D 105-6421 DC COIL DPDT 415XBX-6D 105-1422 415XBX-12D 105-3422 415XBX-24D 105-4422 415XBX-110D 105-6422 AC COIL 2 POLE N.O.. 415BXX-6A 105-1520 415BXX-12A 105-3520 415BXX-24A 105-4520 415BXX-120A 105-6520 AC COIL 2 POLE N.C.. 415XXB-6A 105-1521 415XXB-12A 105-3521 415XXB-24A 105-4521 415XXB-120A 105-6521 415XXB-240A 105-7521 AC COIL DPDT 415XBX-6A 105-1522 415XBX-12A 105-3522 415XBX-24A 105-4522 415XBX-120A 105-6522 415XBX-240A 105-7522 NOTE: THE 105 STYLE IS SLIGHTLY SMALLER WITH A DIFFERENT MOUNTING HOLE PATTERN. GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: 80% of nominal voltage or less measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 25 mS Max. @ Nominal Voltage. 10mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: 1500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Weight: AC: -45˚C to +55˚C @ rated operation. DC: -45˚C to +70˚C @ rated operation 20 Million Operations no load 200,000 Operations @ Rated Load. 500,000 Operations @ 1/2 rated load. 4 oz. (113 g) approx. PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 150 SERIES MOTOR REVERSING CONTACTOR, 1 & 3 HP, 6 POLE A275 The Series A275 relay is a 2 coil, compact motor reversing contactor which finds extensive applications in the Industrial door operator Industry, the hoist Industry and electronic wheel balancers, to name a few. The A275 has Q.C. coil terminals extending out the back (opposite the contact terminals), mechanically interlocked armatures is a standard feature. UL Recognized File No. E13224B OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeters) 2.985 (75.81 2.56 (65.0) 2.31 (58.9) 1.59 (40.3) 3.37 (85.6) UP 3.62 (91.9) .187 (4.76) 2 holes for #8 screws A U X RECOMMENDED MOUNTING POSITION 2.75 (69.8) WIRING DIAGRAM TOP VIEW Main contact terminals are numbered on contactor Struthers-Dunn ORDERING CODE Typical Type No. A275 KXX Series A275, 1/4" Terminals, motor reversing. Continuous , 1 & 2 Hp, 3 pole models Contact Arrangements KXX (3PDM-NO., per coil) Options 2 Aux. contacts, each SPDT (1 per coil) 1/4" Q.C. terminals - CODE 90 4 Aux. contacts, each SPDT (2 per coil) 1/4" Q.C. terminals - CODE 91 Rectified Coil - CODE V2 Coil Voltage AC: 12, 24, 110, 120, 220, 240 (Add "A") DC: 12, 24, 32, 48, 120 (Add "D") 90 -24A 1 2 3 4 5 6 7 8 9 Auxiliary contact Snap Switches OPTIONS (CONSULT FACTORY) PAGE 151 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 MOTOR REVERSING CONTACTOR, 1 & 3 HP, 6 POLE SERIES A275 GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: AC: 85%, DC: 80% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 50 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: 2500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Weight: AC: -45˚C to +50˚C @ rated operation. DC: -45˚C to +70 ˚C @ rated operation. 5 Million Operations no load 100,000 Operations @ Rated Load. 500,000 Operations @ 1/2 rated load. 1 pound, approx.. CONTACT RATINGS DC COIL SPECIFICATIONS @ 25˚C AC CONTACTS: Rated with all contacts in use, not rated per pole. VOLTAGE (60HZ) 120 240 240 480/600 PHASE 1-2-3 1 2-3 2-3 MOTOR RESISTIVE LOADS (HP) LOAD (AMPS) 15 1 10 1.5 10 3 5 3 DC CONTACTS VOLTAGE (DC) 30 125 RESISTIVE LOAD (AMPS) 15 5 600 volt spacing to ground. 300 volt spacing for auxiliary contacts. Nominal Voltage 12 24 32 48 120 Resistance Power Ohms ± 10% Consumption 31.0 4.5W 125 4.6W 210 4.9W 500 4.6W 3240 4.4W Polypropylene encapsulated coils AC COIL SPECIFICATIONS @ 25˚C Resistance Power Nominal Ohms ± 10% Consumption Voltage 17VA 1.24 12V/50-60hz 16.7VA 4.63 24V/50-60hz 16.8VA 125 110V/50-120V/60hz 16.8VA 500 220V/50-240V/60hz WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 152 SERIES A575 2 COIL MOTOR REVERSING CONTACTOR 1.5 - 7.5HP, 6 POLE The Series A575 relay is rated to 7.5 HP. Two sets of 3 pole, double-make, N.O. contacts are mechanically Interlocked to prevent simultaneous closure. Front mounted auxiliary contacts are available for electrical lockup and lockout. All versions have silver cadmium oxide contacts. The A575 motor reversing contactor is widely used for control of overhead doors, elevators, hoists, machine tools, and other similar devices that requires frequent jogging. UL Recognized File No. E13224 OUTLINE DIMENSIONS Dimensions shown in Inch and (Millimeters) NO NC NO COM NC COM 2.56 (65.0) 3.40 (86.3) 4.43 (112.5) MTG. HOLES .196 DIA. (4.97) 2 PLACES 4.75 (120.6) 5.25 (132) UP MAXIMUM DEPTH DIMENSION OF CONTACTOR 3.00", (76.2) RECOMMENDED MOUNTING POSITION WIRING DIAGRAM Struthers-Dunn ORDERING CODE Typical Type No. A575 KXX Series A575, Screw Terminals, 2 coil motor rev. contactor, 1.5 - 7.5 HP Contact Arrangements KXX (3PDM-NO., per coil) Options 1 Form SPST-NO & SPST-NC Aux. contacts per coil, Rated 5 Amps - CODE 74 SPDT Aux. contact per coil Rated 5 Amps. - CODE 90 Coil Voltage AC: 12, 24, 120, 240, 440, 550 (Add "A") DC: 12, 24, 115-125, 240 (Add "D") 90 -24A 1 3 4 6 7 9 AUXILIARY CONTACTS Mechanical Interlock omitted, Consult Factory OPTIONS (CONSULT FACTORY) PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION PAGE 153 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 2 COIL MOTOR REVERSING CONTACTOR 1.5 - 7.5HP, 6 POLE SERIES A575 GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: AC: 85%, DC: 80% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 60 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: 2500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Weight: -40˚C to +50˚C @ rated operation. 5 Million Operations no load 100,000 Operations @ Rated Load. 250,000 Operations @ 1/2 rated load. 1.5 pounds, approx.. CONTACT RATINGS AC COIL SPECIFICATIONS @ 25˚C (22VA) Nominal Voltage 12 24 *120 240 440 550 Resistance Ohms ± 10% 1.00 5.30 92.0 420 2100 3100 Nominal Current 1.833 AMP 0.917 AMP 0.183 AMP 0.920 AMP 0.050 AMP 0.040 AMP VOLTAGE LOAD (60HZ) 120 3PST-DM-NO 208/240 208/240 (per pole) 480/600 * AC coil is 120, 50-60HZ PHASE 1 1 2-3 2-3 MOTOR RESISTIVE LOADS (HP) LOAD (AMPS) 30 1-1/2 30 3 30 5 15 7-1/2 DC CONTACTS LOAD 3PST-DM-NO (per pole) VOLTAGE (DC) 115 230 RESISTIVE LOAD (AMPS) 15 2 DC COIL SPECIFICATIONS @ 25˚C (10 WATT) Nominal Voltage 12 24 **120 240 Resistance Ohms ± 10% 16.5 58.2 1,450 4,200 Nominal Current 0.727 0.412 0.083 0.055 AUXILIARY CONTACTS LOAD 1 FORM "A" "B" OR "C" VOLTAGE (AC) 120 240 RESISTIVE LOAD (AMPS) 5 5 ** DC coil is 110-125 VDC PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 154 SERIES 101-102-103 50,100 & 200 AMP SINGLE POLE DC CONTACTORS The Series 101, 102 and 103 are DC solenoid-actuated, heavy duty contactors. Each contactor has a single pole, double-make normally open contact. Contacts are enclosed with a molded plastic cover. The series 101 is rated at 50 amps continuous duty. The series 102 is rated 100 amps continuous and the series 103 is rated at 200 amps continuous. Coils are rated for DC only, as standard. The powerful magnetic structure creates very high contact pressure which results in very reliable and low resistance contacts, making them suitable for power applications in telecommunications, elevator and rail mass transit as well as other Industries. OUTLINE DIMENSIONS A B E F UP C RECOMMENDED MOUNTING POSITION D (DEPTH FRONT TO BACK) UP Dimensions shown in Inch and (Millimeters) Dim. A B C D E F RECOMMENDED MOUNTING POSITION 101HXX 2.69 (68.33) 1.87 (47.4) 2.50 (63.5) 1.84 (46.7) 0.40 (10.1) 0.43 (10.9) 102HXX 3.38 (85.73) 2.25 (57.1) 3.22 (81.79) 2.09 (53.0) 0.56 (14.2) 0.50 (12.7) 103HXX 4.25 (107.9) 2.40 (60.9) 3.53 (89.66) 2.65 (67.31) 0.92 (23.3) 0.56 (14.2) Mounting holes (2) - .265 (6.73) Inch Dia. Struthers-Dunn ORDERING CODE Typical Type No. 102 HXX -28D Series 101 Screw Term., 50 Amp, 1 pole 102 Screw Term., 100 Amp, 1 pole 103 Screw Term., 200 Amp, 1 pole Contact Arrangements HXX- 1 Pole D.M.- N.O. Standard. HXH- 2 Pole D.B. -1 N.C. and 1 N.O.103 only. JXX- 2 Pole D.M. N.O XRX- SPDT-M-B (Make before break, 103 only) XXH- 1Pole-D.B. + 1NC (103 only) WIRING DIAGRAM 101HXX 102HXX 103HXX Coil Voltage DC: 12, 28, 48, (Add "D") Note: Contact arrangements other than the standard HXX will require a 3 digit suffix number to be added to the type number. This is done by the factory and will be shown after the contact arrangement code. Contact factory for suffix number. OPTIONS (CONSULT FACTORY) AC COIL INPUT VOLTAGES NON STANDARD DC COIL VOLTAGES PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION PAGE 155 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES 50,100 & 200 AMP SINGLE POLE DC CONTACTORS 101-102-103 GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: DC: 80% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 60 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: 1500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: -45˚C to +65˚C @ rated operation. LIFE EXPECTANCY Mechanical: Electrical: 500,000 Operations no load 100,000 Operations @ Rated Load. TERMINALS Coil 101 - #6-32 102 - #8-32 103 - #8-32 MOUNTING Weight Clearance Holes, ea. .265 in dia. 13 oz., 370 Grams Load Term. #10-32 #1/4-20 #3/8-18 AC CONTACT RATINGS RESISTIVE LOAD (AMPS) VOLTAGE AC (60HZ) Series 101 Series 102 Series 103 50 120 200 100 50 240 200 100 DC CONTACT RATING VOLTAGE (DC) 30 RESISTIVE LOAD (AMPS) 50 100 200 DC COIL SPECIFICATIONS @ 25˚C Nominal Voltage (VDC) 12 28 48 101HXX (9W Max) 102HXX 103HXX (10.5W Max) (13.3W Max) Resistance Resistance Resistance Ohms ± 10% Ohms ± 10% Ohms ± 10% 17 10.8 26 75 59 98 290 173 267 PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 156 SERIES 20 AMP GROUND FAULT INTERRUPT (GFI) RELAY 214 The Series 214 Ground fault interrupt relay (GFI) to our knowledge, the smallest relay ever, to pass Underwriters Laboratories 20 Amp overload test for ground fault interrupting devices. Both resistive and Inductive loads of 120 Amps at 120 volts must be switched ten times each without failure. The 214 GFI is most commonly found in portable (plug) GFI equipment. This relay is also appropriate for other applications where size, weight, and the ability to safely handle occasional severe overloads is of primary importance. OUTLINE DIMENSIONS Dimensions shown in inch and (Millimeters) UL Recognized File No. E13224 # 17 AWG Stranded tinned copper wire insulated with .032 thick wall gray silicone rubber 1.37 (34.7) .839 (21.3) WIRING DIAGRAM +.000 +.000 .900 - .010 0.30 Max. (7.62) (22.8) .900 - .010 (22.8) CL 1.00 (25.4) .500 (12.7) 0.70 x .150 slot (2 places) Mounting hole # 6-32 thd. .375 deep min. with .250 full form threads VOLTAGE AC (50/60HZ) 120 240 COIL SPECIFICATIONS @ 25˚C Nominal Nominal Resistance Voltage Ohms ± 10% Power (mA) (VDC) 360 6 5 175 20 12 90 24 80 17 115 2000 VOLTAGE (DC) 30 Nominal Resistance Ohms ± 10% Power (mA) 30 120 480 10,000 200 100 50 11.5 RESISTIVE LOAD (AMPS) 20 * Normally open contact switched 10 times GENERAL SPECIFICATIONS DC: 80% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. Struthers-Dunn TIMING Operate Time: Release Time: 15 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage. 214 DIELECTRIC STRENGTH All Mutually Insulated Points: 2000 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. HXX -24D Series Open Style, Tapped pole piece with antirotation tab. solder terminals on .Coil, # 17 AWG wire contacts. Contact Arrangements HXX (1 Pole double make N.O.) Standard BXX DPST-NO (2 Form A) Coil Voltages AC: 6, 12, 24, 120 ( Add A) DC: 6, 12, 24, 110-125 (Add "D") TEMPERATURE Temperature Rating: EXPECTANCY Mechanical: Overload: Electrical: -45˚C to +65˚C @ rated operation. LIFE TERMINALS OPTIONS The 214 GFI is normally custom built to meet each Customers unique requirements. Consult Factory. MISCELLANEOUS Mounting position: Weight: 10,000,000 Operations no load 120 VAC @ 120 Amps, 10 cycles 100,000 Operations @ Rated Load. Coil Load Terminals Pierced Solder lug # 17 AWG. Silicone Rubber. Tapped pole piece & anti rotation Tab. Any 2.5 oz. 71 Grams PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION PAGE 157 - COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: NOTE: Other DC voltages available with or without rectifiers installed. AC versions without rectifiers can be supplied but not recommended. Consult Factory ORDERING CODE Typical Type No. RESISTIVE LOAD (AMPS) CONTINUOUS MAX. OVERLOAD 20 120 * 20 DC CONTACT RATING DC COIL AC COIL 50/60hZ 0.62 x .093 slot (2 places) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 GENERAL SPECIFICATIONS CLASS MDR MDR'S ARE IDEAL FOR SWITCHING RESISTIVE, TUNGSTEN, AND MOTOR LOADS FOR BOTH AC AND DC APPLICATIONS. PROTECTIVE CO IL COVERS UL Listed File No. E52197 HERMETICALLY SEALED IN STEEL TUBES Every contactor tube is hermetically sealed to provide maximum life, protection to the user from arcing and the hazards of switching heavy loads with exposed contacts. LIQUID MERCURY CONTACT Liquid mercury means a new contact surface after every operation. Mercury is self-renewing, it cannot pit, weld, disintegrate or oxidize. The internal resistance of the contact surfaces typically measure only a few Milliohms and is ideal for switching large loads safely. SPECIFICATIONS MERCURY DISPLACEMENT RELAYS COIL Frequency of Operation: Pull-in voltage Dropout voltage CONTACTS Material: Contact resistance: TIMING Operate (at nominal voltage) Dropout (at nominal voltage) 60 per minute maximum 80% of nominal voltage, Typ. AC & DC coils. 78% of nominal voltage, typ. AC coils 65% of nominal voltage, typ. DC coils Mercury .002 ohm M60 & M100 .003 ohm M30 & M35 50 Milliseconds typical 80 Milliseconds typical DIELECTRIC STRENGTH All mutually insulated points to ground: 2650 V rms TEMPERATURE Operating: - 35˚C to + 60˚C Under continuous load. LIFE Mechanical: (No load) Electrical (Rated load) 5,000,000 Operations 250,000 Operations MISCELLANEOUS Insulation Material: Mounting: Options: Class B - 130˚C & M35 pressure connectors for AWG 6-14 wire; M60 pressure connectors for AWG 2 - 12 wire Vertical ±10˚ Combination of SPST-NO & SPST-NC contact configurations. available. Other coil voltages available . WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 158 CLASS MDR APPLICATION DATA MERCURY DISPLACEMENT TUBE GLASS INSULATOR WELD PLUNGER GUIDE CERAMIC LINER ELECTRODE ARC QUENCHING ATMOSPHERE MAGNETIC LINER PLUNGER GUIDE BUFFER SPRING MERCURY POOL STAINLESS STEEL CAN PRINCIPLE OF OPERATION The sectional view shows our normally open style Mercury Displacement tube with the plunger assembly floating on the mercury pool. When the coil power is off, the mercury level is below the electrode tip. No electrical path exists between the electrode and mercury pool. When coil power is applied, the plunger is drawn down into the mercury by the pull of the magnetic field. This action raises the mercury level, so it covers the end of the electrode closing the circuit. When coil power is turned off, the buoyant force of the mercury causes the plunger assemble to rise, dropping the mercury level, and breaking the circuit. APPLICATION DATA Mercury Displacement relays are ideal for adverse environments....Where high inrushes are encountered ....Where hermetically sealed contact operation is required because of corrosive, dirty, or moist ambient conditions. ....Where use does not permit contact maintenance. ....Where reduced noise levels are required. ....where minimum weight and size are desired. DESIGN FEATURES Liquid Mercury Contact - provides a new contact surface with every actuation. Mercury is self-renewing and does not pit, weld, disintegrate or oxidize. Hermetic sealing - provides internal and external protection from arcing. Inert Gas atmosphere - contactor tube is evacuated, then pressurized with a combination of gases which extinguish arcing and contribute to long life. The pressurized gases provide for a high dielectric withstanding voltage between contact surfaces. Low Contact Resistance - Large electrode and mercury volume creates low contact resistance and provides high inrush current capability. Quiet Operation - Switch clacking normally associated with conventional hard contactors, is eliminated with mercury displacement tubes and the buffer spring assembly. APPLICATION OF "M" SERIES VS "ML" SERIES The series "ML" is physically the same as the "M" series except for the type of gases used in the contactor tubes. The "ML" series was developed for use with resistive and tungsten loads on AC power ONLY. The "ML" series will give much greater life than the "M" series for these types of loads and is intended for high activation use, such as molding machines or ovens. The "ML" series, however is not intended for use with motor loads on AC power, or for resistive, tungsten, or motor loads on DC power. The "M" series, which is our universal series is rated to be used on all types of loads resistive, tungsten, and motor for both AC and DC power PAGE 159 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 30 AMP MERCURY DISPLACEMENT RELAY CLASS MDR CLASS M30 RATED 30 AMPS SWITCHES RESISTIVE TUNGSTEN, AND MOTOR LOADS 1 POLE N.O. CONTACT CONTACTOR TERMINALS .180 Dia. (4.6) 2 Holes COIL TERMINALS 4.18 (106.4) 2.03 (51.6) 1.187 (30.2) 2.0 (50.8) UL Listed File No. E52197 1.62 (41.3) 2.12 (58.7) .531 (13.5) UP RECOMMENDED MOUNTING POSITION ± 10˚ FOR EXTENDED LOAD LIFE WHEN SWITCHING RESISTIVE AND TUNGSTEN LOADS ORDER THE ML30-STYLE. OTHER COIL VOLTAGE AND CONTACT COMBINATIONS AVAILABLE. CONSULT FACTORY. Construction in accordance with VDE 0660 and 0110 (Insulation group 380) Weigh: 13 ozs. 370 grams VOLTAGE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 125VDC 250VDC CONTACTOR RATINGS FOR M30A - M30B RESISTIVE MOTOR HP PHASE AMPS AMPS 1Ø 3Ø 1Ø 3Ø 24 1Ø 3Ø 2* 19.2 3* 30* 28 5* 19 7.5* 30* 1Ø 3Ø 1Ø 3Ø 14 5* 10* 14 30* 11.2 11 5* 10* 1Ø 3Ø 25 ** DC 1/2 30* 27 DC 1/2 30* 13.5 DC 1/2 16* 5.2 DC 1/2 12* 2.6 * UL and CSA Listed TUNGSTEN AMPS 30* 15 7.5 6 30* 30* 16* 12* ** CSA only PART NUMBER NOMINAL INPUT VOLTAGE WM30A-120A 120 VAC COIL Measured @ 25˚C NOMINAL NOMINAL RESISTANCE CURRENT (OHMS) 700 .058 NOMINAL POWER 7VA PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 160 CLASS M35 AND M60 DIMENSIONS MDR DIMENSION 1 POLE A B C 2 POLE D E 3 POLE F G H J M60A-ML60A M60B-ML60B M35A-ML35A M35B-ML35B 2.375 Max. (60.3) 5.06 Max. (128.52) 1.06 Max. (27) 3.250 Max. (82.6) 5.062 Max. (128.52) 1.812 Max. (46.0) 3.250 Max. (82.6) 5.062 Max. (128.52) 1.812 Max. (46) 1.50Max. * (38.1) 5.062 Max. (128.52) 1.937 Max. (49.2) 2.281Max. (57.9) 5.062 Max. (128.52) 2.781 Max. (70.6) 2.281 Max. (57.9) 5.062 Max. (128.52) 2.781 Max. (70.6) 2.312 Max. (58.7) 4.875 Max. (123.8) 0.937 Max. (23.8) 3.187 Max. (81.0) 4.875 Max. (123.8) 1.687 Max. (42.9) 3.187 Max. (81.0) 4.875 Max. (123.8) 1.687Max. (42.9) 1.375 Max. (34.9) 4.875 Max. (123.8) 1.875 Max. (47.6) 2.218 Max. (56.3) 4.875 Max. (123.8) 2.656 Max. (57.4) 2.218 Max. (56.3) 4.875 Max. (123.8) 2.656 Max. (67.4) * SPST-NC outline is not shown. The SPST-NC tube is positioned lower on the coil so Dimension A is lower, but the overall height remains the same. DIMENSIONS SHOWN IN INCHES AND (MILLIMETERS) 3.12 (79.4) 2.28 (58) CONTACTOR TERMINALS CONTACTOR TERMINAL .180 Dia. (4.6) 2 Holes .205 Dia. (5.2) 4 Holes D A B 2 POLE 35AMP OR 60 AMP 1 POLE 35AMP OR 60 AMP 1.77 (45) COIL TERMINALS COIL TERMINALS 1.93 (49.2) E 1.62 (41.3) F C 3.50 (88.9) 2.06 (52.4) 1.187 (30.2) 2.0 (50.8) 2.312 (58.7) 2.312 (58.7) 3.75 (95.3) 3.12 2.75 (79.4) (69.9) CONTACTOR TERMINAL 30˚ 30˚ .205 Dia. (5.2) 6 Holes G COIL TERMINALS 1.93 (49.2) 3 POLE 35AMP OR 60 AMP H 1.77 (45) J 2.28 (58) PAGE 161 3.36 (85.5) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS 35 AND 60 AMP MERCURY DISPLACEMENT RELAYS MDR CLASS WM35 and WM60 SWITCHES RESISTIVE, TUNGSTEN, AND MOTOR LOADS STAINLESS STEEL TUBE S HIGH INRUSH CAPACITY UL Listed File No. E52197 1 POLE Weight 13 Ozs., (370 Grams) CONTACTOR RATINGS FOR M35A - M35B VOLTAGE PHASE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 125VDC 250VDC 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø DC DC DC DC * UL and CSA Listed HP 1Ø 3Ø 3* 5* 5* 7.5* 5* 10* 5* 10* 1/2 1/2 1/2 1/2 RESISTIVE AMPS MOTOR AMPS 1Ø 3Ø 34 30 28 19 14 14 11.2 11 27 13.5 5.2 2.6 35* 35* 35* 25 ** 35* 35* 16* 12* TUNGSTEN AMPS 35* 17 9 7 35* 35* 16* 12* ** CSA only 2 POLE Weight 26 Ozs., (738 Grams) CONTACTOR RATINGS FOR M60A - M60B VOLTAGE PHASE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 125VDC 250VDC 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø DC DC DC DC HP 1Ø 3Ø 3* 5* 5* 10* 7.5* 15* 7.5* 15* 3/4 3/4 3/4 3/4 MOTOR AMPS 1Ø 3Ø 34 30 28 28 21 21 16 17 39 19.5 7.4 3.7 RESISTIVE AMPS 60* 60* 60* 50 ** 60* 60* 40* 20* * UL and CSA Listed ** CSA only SEE MDR GENERAL SPECIFICATIONS AND DIMENSIONS. TUNGSTEN AMPS AMPS "B" (N.C.) "A" (N.O.) 45* 60* 22.5 30 11.2 15 9 12 50* 50* 50* 50* 40* 40* 20* 20* UP 3 POLE Weight 2Lbs. 6 ozs., (1078 Grams) RECOMMENDED MOUNTING POSITION ± 10˚ COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL NOMINAL PART RESISINPUT CURRENT POWER NUMBERS TANCE VOLTAGE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT WM35A-120A 700 7VA .058 120 VAC WM35A-240A 2,800 7VA .029 240VAC, 60HZ 220VAC, 50HZ WM35A-24D 186 3.5W .120 24VDC 2 POLE NORMALLY OPEN CONTACTS WM35AA-120A 218 16.5VA .135 120 VAC WM35AA-240A 1,200 16.5VA .063 240VAC, 60HZ 220VAC, 50HZ WM35AA-24D 98 6W .232 24VDC 3 POLE NORMALLY OPEN CONTACTS WM35AAA-120A 120 VAC 111 28VA .220 WM35AAA-240A 240VAC, 60HZ 430 28VA .117 220VAC, 50HZ WM35AAA-24D 24VDC 64 9W .375 1 POLE NORMALLY CLOSED CONTACT WM35B-120A 460 13VA .115 120VAC COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL NOMINAL PART RESISINPUT CURRENT POWER NUMBERS TANCE VOLTAGE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT WM60A-120A 700 7VA 120 VAC ..058 WM60A-240A 2,800 7VA 240VAC, 60HZ .029 220VAC, 50HZ WM60A-24D 186 3.5W 24VDC .120 2 POLE NORMALLY OPEN CONTACTS WM60AA-120A 120 VAC 218 16.5VA .135 WM60AA-240A 240VAC, 60HZ 1,200 16.5VA .063 220VAC, 50HZ WM60AA-24D 98 6W 24VDC .232 3 POLE NORMALLY OPEN CONTACTS WM60AAA-120A 120 VAC 111 28VA .220 WM60AAA-240A 240VAC, 60HZ 430 28VA .117 220VAC, 50HZ WM60AAA-24D 24VDC 64 9W .375 1 POLE NORMALLY CLOSED CONTACT WM60B-120A 460 13VA 120VAC .115 PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 162 CLASS 35 AND 60 AMP MERCURY DISPLACEMENT RELAYS MDR CLASS WML35 and WML60 UL Listed File No. E52197 RECOMMENDED FOR MUCH LONGER LIFE WHEN SWITCHING RESISTIVE AND TUNGSTEN LOADS. AVAILABLE FOR AC LOADS ONLY. NOT RECOMMENDED FOR SWITCHING DC LOADS. UP 2 POLE Weight 26 Ozs., (738 Grams) 1 POLE Weight 13 Ozs., (370 Grams) 3 POLE Weight 2Lbs. 6 ozs., (1078Grams) RECOMMENDED MOUNTING POSITION ± 10˚ CONTACTOR RATINGS FOR ML35A - ML35B CONTACTOR RATINGS FOR ML60A - ML60B VOLTAGE RESISTIVE AMPS TUNGSTEN AMPS VOLTAGE RESISTIVE AMPS 120VAC 240 VAC 480VAC 600VAC 35* 35* 35* 25 ** 35* 17 9 7 120VAC 240VAC 480VAC 600VAC 60* 60* 60* 50 ** * UL and CSA Listed ** CSA only * UL and CSA Listed TUNGSTEN AMPS AMPS "B" (N.C.) "A" (N.O.) 45* 60* 22.5 30 11.2 15 9 12 ** CSA only COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL RESISCURRENT POWER TANCE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT WML35A-120A 700 7VA ..058 120 VAC WML35A-240A 2,800 7VA .029 240VAC, 60HZ 220VAC, 50HZ 2 POLE NORMALLY OPEN CONTACTS COIL Measured @ 25˚C NOMINAL PART NOMINAL NOMINAL RESISNUMBERS CURRENT POWER TANCE (AMPS) (OHMS) 1 POLE NORMALLY OPEN CONTACT 120 VAC 700 7VA WML60A-120A ..058 240VAC, 60HZ 2,800 7VA WML60A-240A .029 220VAC, 50HZ 2 POLE NORMALLY OPEN CONTACTS WML35AA-120A WML35AA-240A WML60AA-120A WML60AA-240A NOMINAL INPUT VOLTAGE PART NUMBERS 218 .135 120 VAC 1,200 .063 240VAC, 60HZ 220VAC, 50HZ 3 POLE NORMALLY OPEN CONTACTS WML35AAA-120A 120 VAC WML35AAA-240A 240VAC, 60HZ 220VAC, 50HZ 111 430 .220 .117 16.5VA 16.5VA NOMINAL INPUT VOLTAGE 120 VAC 240VAC, 60HZ 220VAC, 50HZ 218 1,200 3 POLE NORMALLY OPEN CONTACTS 28VA 28VA WML60AAA-120A 120 VAC WML60AAA-240A 240VAC, 60HZ 220VAC, 50HZ 111 430 16.5VA .135 16.5VA .063 . 28VA .220 28VA .117 PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION . PAGE 163 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS 100 AMP MERCURY DISPLACEMENT RELAYS MDR CLASS WM100 CAPABLE OF SWITCHING 100 AMP LOADS UP TO 480 VAC /48VDC AVAILABLE IN 1 POLE N.O. CONTACTS ONLY. LOAD TERMINALS AWG #1 THRU #8 WIRE .187 Dia. (4.7) 2 Holes UL Listed File No. E52197 3.00 Max. (76.2) 5.87 Max. (149) UP 1.87 (4.7) 1.00 Max. (25.4) 2.09 Max. (53.0) 3.50 Max. (88.9) RECOMMENDED MOUNTING POSITION ± 10˚ 3.37 Max. (85.59) SPECIFICATIONS FOR WM100 COIL 60 per minute max. Frequency of Operation: 80% of nominal voltage, Typ. AC & DC coils. Pull-in voltage: 78% of nominal voltage, typ. AC coils. Dropout voltage: 65% of nominal voltage, typ. DC coils. CONTACTS Mercury. Material: .,001 ohm Typical. Contact resistance: TIMING Operate (at nominal voltage): Dropout (at nominal voltage): 50 Milliseconds typical. 100 Milliseconds typical. DIELECTRIC STRENGTH Across open Contact: Coil to Contact: Contact to Frame: Coil to Frame: 2650 V rms. 2650 V rms. 2650 V rms. 2650 V rms. TEMPERATURE Operating: - 35˚C to + 60˚C Under continuous load. LIFE Mechanical (No load): Electrical (Rated load): 5,000,000 Operations. 100,000 Operations. MISCELLANEOUS Insulation Material: Terminals: Options: Weight: Class B - 130˚C. # 1 thru 8 AWG wire. Coil Voltages from 12VAC to 480VAC, 5VDC. thru 250VDC. Consult Factory. 15.87 ozs. 450 grams. CONTACTOR RATINGS FOR M100 PART NUMBERS 1 WM100A-120A WM100A-240A WM100A-24D COIL Measured @ 25˚C NOMINAL NOMINAL NOMINAL NOMINAL RESISINPUT CURRENT POWER TANCE VOLTAGE (AMPS) (OHMS) POLE NORMALLY OPEN CONTACT 120 VAC 33VA .275 73.5 240VAC, 60HZ 33VA .138 300 220VAC, 50HZ 24VDC 10W .380 53 VOLTAGE 120VAC 240VAC 480VAC 600VAC 24VDC 48VDC 120VDC 250VDC RESISTIVE TUNGSTEN HORSEPOWER SINGLE PHASE AMPS AMPS 100 100 100 80* 100 100 80 40 100* 60 30* 24* 100 100 80 40 3 5 15 10* 1.5* 1.5* 1.5* 1.5* PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION * NON UL RATING PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 164 SERIES 102,103 50 &100 AMP, 2-POLE LIGHTING CONTACTORS The Series 102 and 103 are solenoid types utilizing a DC coils with a full wave bridge rectifiers which allows the device to operate from an AC supply. Coil power consumption is less than 10 watts for the series 102, less than 20 watts for the 103. The contacts are Double make type, each set capable of switching and continuously carrying at least 50 Amps for the series 102 and 100 Amps for the series 103 at up to 480 volts AC. The contactors are typically constructed and wired to be directly interchangeable with existing hour meter base with separate wire leads for connection to the controlling device. Because of their compact construction, these contactors can be adapted to retrofit almost any existing type. Contact our Factory for details. 6.0 .6) 2 (15 WIRING DIAGRAM 3.0 .2) (76 6.0 (152.6) 102JXX 103JXX UP VOLTAGE AC (60HZ) 120 240 RECOMMENDED MOUNTING POSITION AC CONTACT RATINGS RESISTIVE LOAD (AMPS) Series 102 Series 103 200 100 200 100 DC CONTACT RATING VOLTAGE (DC) 30 RESISTIVE LOAD (AMPS) 100 200 UNITS WIRED FOR 50 & 100 AMP LAMP LOAD SERVICE GENERAL SPECIFICATIONS Struthers-Dunn ORDERING CODE Typical Type No. 102 JXX -110D COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: DC: 80% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: 60 mS Max. @ Nominal Voltage. 30 mS Max. @ Nominal Voltage. Series 102 Screw Term., 50 Amp. 103 Screw Term., 100 Amp. DIELECTRIC STRENGTH All Mutually Insulated Points: 1500 V rms between all mutually Insulated current carrying parts and those parts to ground. Insulation Resistance: 500 VDC Exceeds 1000 Megohms. Contact Arrangements TEMPERATURE Temperature Rating: JXX- 2 Pole D.M. N.O Coil Voltage DC: 6 to 220 (Add "D") AC, FULL WAVE RECTIFIED: 12 to 240 (Add "A") WATT HOUR METER BOX NOT SUPPLIED WITH 102/ 103 CONTACTOR. PAGE 165 EXPECTANCY Mechanical: Electrical: -45˚C to +65˚C @ rated operation. LIFE TERMINALS MISCELLANEOUS Mounting: Weight: 500,000 Operations no load 100,000 Operations @ Rated Load. Coil 102 - #8-32 103 - #8-32 Load Term. #1/4-20 #3/8-18 Wall Mounting.. 42 oz., 1.2 kg Grams> WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 S E C T I O N 7 7 LATCHING, SEQUENCE AND STEPPER RELAYS 5 TO 30 AMPERES Page 166 Magnecraft Struthers-Dunn LATCHING RELAYS TO 10 AMP 250ML 388ML/285 308 255 OCTAL 11 PIN PLUG-IN PERMANENT MAGNETIC LATCHING RELAY PERMANENT MAGNETIC LATCHING RELAY 2 COIL MECHANICAL LATCHING. SINGLE OR DUAL COIL 3 WAY TERMINALS: SOLDER, 0.187" Q.C. OR PLUG IN. RELAY SERIES FEATURES DUAL COIL LATCHING SELF-MAINTAINING SET AND RESET COILS MAINTAINS LAST POSITION WITHOUT POWER 3 WAY TERMINALS: SOLDER, 0.187" Q.C. OR PLUG IN. AC OR DC COILS HIGH SENSITIVITY COILS AVAILABLE AC OR DC INPUT CONTACT DATA CONTACT CONTACT CONTACT MATERIAL: RESISTANCE: CONTINUOUS DUTY COILS BOTH COILS MAY BE NO FALSE TRANSFER ENERGIZED SIMULTAWITH 5 TIMES NOMINAL NEOUSLY WITHOUT VOLTAGE PULSE DAMAGE. SPDT, 3PDT, OR UP TO 4 FORM A, OR FORM B . DPDT DPDT 4PDT 10 AMPS @ 120 VAC/ 30 VDC 10 AMPS @ 120/240VAC 10 AMPS @ 28 VDC 10 AMPS @ 120, 1/3 HP 10AMPS @ /240, 1/2 HP 10 AMPS @ 28 VDC SILVER CADMIUM OXIDE GOLD FLASHED 100 MILLIOHMS (INITIAL) SILVER CADMIUM OXIDE GOLD FLASHED 50 MILLIOHMS (INITIAL) SILVER CADMIUM OXIDE 50 MILLIOHMS (INITIAL) SILVER CADMIUM OXIDE OR GOLD DIFFUSED 50 MILLIOHMS (INITIAL) 1500 V rms 1500 V rms 1500 V rms 1500 V rms 120 12, 24 6 to 240 6 to 125 3.4VA 1.9 WATTS 3.4 VA 1.2 -1.9 WATTS 6 to 240 6 to 125 (250V WITH SERIES RESISTOR) 5 OP 3 RESET 1.8 OP 1.9 RESET CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: AC OR DC INPUT SINGLE LEVEL SOCKET WIRING 30AMPS @ 120 CARRY 10A, BREAK 10A. 30AMPS @ /240 CARRY 10A, BREAK 5A. 30 AMPS @ 125 VDC CARRY 10A, BREAK 0.5A. INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC) 24, 120, 240 12 , 24, 110 6 VA 1.64 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: TIMING VALUES OPERATE: RELEASE: - 45˚ C to + 70˚ C 30 30 LIFE MECHANICAL: ELECTRICAL: MILLISECONDS MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS DIMENSIONS H W L 1.41 x 1.41 x 3.17 APPROVALS Pending APPLICATION DATA: PAGE 169 PAGE NUMBER: PAGE 170 PAGE 167 - 45˚ C to + 70˚ C - 45˚ C to + 70˚ C - 10˚ C to + 60˚ C 25 ms AC/15 ms DC 25 ms AC/15 ms DC 25 ms AC/15 ms DC 25 ms AC/15 ms DC 25 MILLISECONDS 20 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS 10 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.40 X 1.53 X 1.90 C H W L 1.50 X 1.93 X 1.87 10 MILLION OPERATIONS 100,000 OPERATIONS H W L 2.62 X 1.46 X 4.56 US PAGE 171, 172 PAGE 173, 174 PAGE 175, 176 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 Magnecraft Struthers-Dunn LATCHING & STEPPING RELAYS 88L& 88LCP RELAY SERIES FEATURES 311 OPEN STYLE OR ENCLOSED STYLE SEQUENCE (STEPPING) RELAY HEAVY DUTY SEQUENCE RELAY DUAL COIL, MECHANICAL LATCHING. SINGLE COIL CONTINUOUS DUTY. POSITIVE ACTION SEQUENCING CAM UP TO 6 FORM "C", 3 POLES PER COIL CONTACT TRANSFER ON ENERGIZING OR DE-ENERGIZING STROKE OF RELAY FRONT CONNECTED TERMINALS AC 50/60HZ, & DC COILS AVAILABLE SOLDER TERMINALS OR 20 PIN OCTAL PLUG-IN CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT MATERIAL: CONTACT RESISTANCE: ANY SEQUENCE UP TO 12 STEPS SINGLE LEVEL SOCKET WIRING CONTACT DATA CONTACT C85 UP TO 6PDT DPDT DPST-NO or NC & 1SPST-NC 0AMP 120VAC 10AMP 240VAC 10 AMP 28VDC 5 AMPS @ 120VAC 5 AMPS @ 28 VDC 0.1 AMPS 125 VDC 20AMP 120VAC 20AMP 240VAC 20 AMP 30VDC SILVER CADMIUM OXIDE SILVER CADMIUM OXIDE FINE SILVER 100 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH: 1500 V rms 1500 V rms 120 12 6 to 240 6 to 110-125 6VA 2.5 5VA 1.8 WATTS COIL DATA AC - VOLTAGE: DC - VOLTAGE: POWER: VA,: (VAC) WATTS,: (VDC) 1500 VAC 24 to 550 24 to 240 18VA 14 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE: - 10˚ C to + 50˚ C (AC) - 10˚ C to + 60˚ C (DC) - 10˚ C to + 60˚ C - 45˚ C to + 65˚ C TIMING VALUES OPERATE: RELEASE: 25 MILLISECONDS 25 MILLISECONDS 35 MILLISECONDS 35 MILLISECONDS 50 MILLISECONDS 50 MILLISECONDS LIFE MECHANICAL: ELECTRICAL: 5 MILLION OPERATIONS 100,000 OPERATIONS DIMENSIONS 5 MILLION OPERATIONS 100,000 OPERATIONS H W L 1.93 X 1.75X 2.87 H W L 2.62 X 1.46X 3.406 PAGE 177, 178 PAGE 179 500,000 OPERATIONS 100,000 OPERATIONS H W L 2.625 X 3.00 X 5.00 APPROVALS PAGE NUMBER PAGE 180 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 168 SEQUENCE & LATCHING RELAY APPLICATION NOTES APPLICATION DATA WHAT IS A SEQUENCE RELAY: SEQUENCE APPLICATIONS CONTINUED: A Sequence relay is sometimes called an alternator, stepper, flip-flop, or impulse relay. The relay has the ability to open and close it's contacts in a preset sequence. All sequence relays use a ratchet or catch mechanism to cause their contacts to change state by repeated impulses to a single coil. Usually, but not always, one pulse will close a set of contacts, the next will open them, and so on back and forth. This alternating of open and closed states has many possible uses. A typical example is remotely starting and stopping a conveyer from a single momentary push button. Several momentary push buttons might be wired in parallel to control the conveyer from a number of locations. A Sequence relay requires a pulsed voltage to the coil of approximately 50 milliseconds for each sequence to take place. When the coil is pulsed, the relay armature moves a lever that in turn rotates the ratchet and cams to the first position in the sequence. This position will remain as long as another pulse is not introduced to the coil. WHAT IS A LATCHING RELAY: The relay is normally comprised of at least two sets of contacts to allow the contacts to alternate in combinations of open and closed states, with each pulse of voltage to the coil. One example of possible two pole combinations, would be where one pole remains open and the other pole is closed with the first pulse applied to the coil. The second pulse could then reverse the above sequence. The third pulse could have both poles closed and the fourth pulse could open both poles. The above example could also have other sequences, depending upon the amount of teeth in the ratchet and the amount of lobes on the cams. Figure 1 shows an example of how cam placement on the contact blades can change the position of the contacts as cams are rotated by the ratchet gear. Cam 1 Another common use for sequence relays is cascade starting of multiple HVAC or other high start-up load systems, to limit the high starting current. Latch relays typically use a permanent magnet or mechanical catch to hold the contacts in their last energized position without the need for continued application of coil power. They are especially useful in applications where power must be conserved, such as a battery operated device, or where it is desirable to have a relay stay in one position if power is interrupted. They should not be used to control a device that could create a safety hazard if it were to restart after a power interruption. Mechanical latch relays are most often constructed in a way that will cause them to go to their operate position when the operate coil is energized regardless of whether the reset coil is energized or not. This "operate coil dominant" feature can be useful in applications where a relay should operate and release like a conventional relay unless a particular action takes place, at which time the release coil would drop out, latching the relay in the operate position. A pallet loader would be a good example of equipment which might utilize this type of operation. Open contact Cam 2 Closed contact FIGURE 1 SEQUENCE APPLICATIONS: Some typical applications for sequence relays is turning one device on and off from a single momentary contact. PAGE 169 Magnetic latching relays are typically designed to be polarity sensitive. When voltage is momentarily applied to the coil with a predetermined polarity, the relay will operate. The relay will remain in the operate position after power is removed from the coil. A permanent magnetic is designed to hold the contacts in the operate position without the need for continued power to the coil. When the polarity is reversed, and momentarily applied to the coil, the armature will push away from the coil overcoming the holding affect of the permanent magnetic, causing the contacts to reset. Both single and dual wound coils use the same principle of operation. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS DUAL COIL, 10 AMP LATCHING RELAYS 250ML 250 ML MAGNETIC LATCHING RELAY WITH 11 PIN BASE. OPERATED BY PULSED INPUT AND MAINTAINS LAST POSITION. CONTACT ARRANGEMENT: DPDT OUTLINE DIMENSIONS PENDING 11 PIN PLUG Artwork marking side Dimensions are shown in Inch and (Millimeter). 2.89 Max. (73.4) 2.33 Max. (59.2) 1.37 (34.79) 6 7 5 8 4 1.37 (34.79) 3 9 2 10 1 11 SPECIFICATIONS CLASS 250 ML COIL Operate Voltage:: Reset Voltage: Duty cycle @ nominal voltage: Coil resistance: Max. allowable voltage: See Table below. (Measured @ 25˚C) See table below. (Measured @ 25˚C) Dual coil are intermittent duty. ± 10 % measured @ 25 ˚C 5 X nominal voltage with no false transfer of contacts during Operate or Reset pulse. Class "B" system (130˚C) per UL STD. 1446 Coil Insulation: Duration of Operate & reset pulse: 50 mS Minimum. CONTACTS Contact material: Contact resistance: Minimum Load: Contact Rating: HERMETICALLY SEALED VERSION AVAILABLE CONSULT FACTORY 3/16" silver cadmium oxide, gold flashed. 50 milliohms maximum initial resistance at rated current 12 V @ 100 Milliamps 10 Amps @ 120/240 VAC, 28 VDC 1/3 Hp @ 120 VAC, 1/2 Hp @ 240 VAC. TIMING Operate time: Release time: (AC) 30 mS Max. (DC) 20 mS Max. @ nominal voltage. (AC) 30 mS Max. (DC) 20 mS Max. @ nominal voltage. DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole: Contacts to frame: Insulation resistance: 1500 V rms 500 V rms 1500 V rms 1500 V rms 1,000 Megohms min. @ 500 VDC WIRING DIAGRAM RESET (+) 6 5 7 4 (-) TEMPERATURE Ambient Temperature (Operating): - 30˚C to +70˚C - 30˚C to +105˚C Non operating storage: 8 3 (-) 9 2 10 1 SHOCK RESISTANCE Latched: 10 G's, VIBRATION RESISTANCE Operating: 5 G's, 10 Hz to 55 Hz MISCELLANEOUS Enclosure: Insulation material: Operating Position: Weight: Plastic dust cover with 11 pin octal base. Molded plastic Any 170 g ( approx.) (+) 11 OPERATE SEE SECTION 10 FOR MATING SOCKETS Stock Part Numbers shown also available thru Stocking Distribution Coil Measured @ 25˚C PART NUMBERS NOMINAL OPERATE VOLTAGE VOLTAGE MIN. DC OPERATED COILS W250ML2CPX-6 12 VDC 8.4 VDC W250ML2CPX-7 24 VDC 16.7 VDC W250ML2CPX-8 110 VDC 77 VDC AC OPERATED COILS W250AML2CPX-8 24 VAC 19.2 VAC W250AML2CPX-9 120 VAC 96 VAC W250AML2CPX-9 240 VAC 192 VAC CROSS REFERENCE COIL RESET NOMINAL TO VOLTAGE RESISTANCE POWER IDEC ( EA. COIL) MIN. 8.4 VDC 16.7 VDC 77 VDC 88/88 Ω 350/350 Ω 4000/4000 Ω 1.64 W 1.64 W 1.64 W RR2KP-U-DC12 RR2KP-U-DC24 RR2KP-U-DC110 19.2 VAC 96 VAC 192 VAC 52/52 Ω 1200/1200 Ω 3200/3200 Ω 6 VA 6 VA 6 VA RR2KP-U-AC24 RR2KP-U-AC120 RR2KP-U-AC240 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 170 CLASS 388ML/285 10 AMP MAGNETIC LATCH RELAY CLASS 388ML/285 10 AMP MAGNETIC LATCH RELAY. SINGLE OR DUAL COIL LATCHING. 1/3HP @ 120VAC 1/2 HP @ 240VAC Recognized Component mark for Canada and the United States. C US UL Recognized File No. E43641 OUTLINE DIMENSIONS Dimensions shown are in "Inches" and (Millimeter) 1.53 Max. (38.8) 1.90Max. (48.4) .187 x .020 (4.76 x 0.51) QC Terminals Typical 1 4 2 5 3 6 7 8 9 1.40Max. (35.5) A B .28 Typ. (7.1) COIL Measured @ 25˚C CROSS REFERENCE COIL NOMINAL OPERATE RESET NOMINAL NOMINAL TO CONFIGUEQUIVALENT PART NUMBERS INPUT VOLTAGE VOLTAGE RESISPOWER POTTER & BRUMFIELD RATION TANCE VOLTAGE (Or Less) (Or Less) (OHMS) AC OPERATED, SINGLE COIL SINGLE 120 VAC 102 VAC 102 VAC 10,000 W388AMLCPX-9 KUL11A15S-120 285XBXC-120A 0.8VA DC OPERATED, SINGLE COIL W388MLCPX-6 SINGLE 12 VDC 9.0 VDC 9.0 VDC KUL11D15S-12 285XBXC-12D 120 1.2W SINGLE 24 VDC 18,0 VDC 18.0 VDC W388MLCPX-7 KUL11D15S-24 285XBXC-24D 470 1.2W DC OPERATED, DUAL COIL W388ML2CPX-6 DUAL KUL11D15D-12 285XBXCD-12D 12 VDC 9.0 VDC 9.0 VDC 88/88 1.64W DUAL W388ML2CPX-7 KUL11D15D-24 285XBXCD-24D 24 VDC 18.0 VDC 18.0 VDC 350/350 1.64W PART NUMBERS STRUTHERS-DUNN PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION PAGE 171 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS 10 AMP MAGNETIC LATCH RELAY 388ML/285 SPECIFICATIONS CLASS 388/285 COIL Pull-in Voltage: AC: 85%, DC: 75% of nominal voltage measured at 25˚C Single coil are continuous duty dual coil are intermittent duty. 30 Milliseconds 5 x Nominal voltage with no false transfer of contacts during operate or reset pulse. 110% of nominal voltage ±10% Measured @ 25˚C Duty Cycle (Nominal V) Pulse Duration Min. Max. allowed voltage: Coil Resistance: CONTACTS Contact Material: Contact configuration: Contact Rating Silver Cadmium Oxide, Gold Flashed. DPDT, (3PDT available) 10 Amps @ 120/240VAC, 28VDC TIMING Operate Time: (@ Nom. V) Release Time: (@ Nom. V) AC: 30 mS max., DC: 20 mS max. AC: 30 mS max., DC: 20 mS max. DIELECTRIC STRENGTH Across open contacts between current carrying parts to ground: Insulation Resistance: 500 V rms 1500 V rms 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: AC: -45˚C to +70˚C @ Rated Operation. LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear polycarbonate 87 grams approx. WIRING DIAGRAM VIEWED FROM PIN END RESET 3 1 1 6 4 4 3 3 1 6 4 5 9 7 A + RESET B 7 COMMON - + OPERATE SINGLE COIL ( DC ) RESET 9 8 OPERATE B A - SINGLE COIL ( AC ) VIEWED FROM TERMINAL END - 6 9 + 8 A B OPERATE 7 - + OPERATE DUAL COIL ( DC ) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 172 SERIES MAGNETIC LATCH 10 AMP, 4 POLE RELAY 308 The series 308 relay combines the basic features of the 284 series relay into a permanent magnet latch relay. It is available with a single wound AC or DC coil. To operate the single-wound DC coil, voltage of proper polarity is applied to the coil, and reset when the polarity is then reversed. For AC coils, power is applied through the operate diode or the reset diode to provide the required function. OUTLINE DIMENSIONS Dimensions shown are in INCHES and (millimeters) 0.218 (5.53) 1.50 (38.1) 1.31 (33.3) MANUAL PUSH BUTTON ACTUATOR (OPTIONAL) 1.93 (49.0) 1.87 (47.4) 0.28 (7.11) 0.187 (4.74) WIRING DIAGRAM (VIEWED FROM TERMINAL END) Struthers-Dunn ORDERING CODE Typical Type No. 308 XDX C LMY -120A Series 308 3 way terminals, Magnetic latch, 10 Amp, 4 pole Contact Arrangements XDX (4 Form "C") Construction Style Enclosed, 3 way terminals - CODE C Options 10 Amp contacts Standard - NO CODE Gold diffused contacts - CODE G Indicator Lamp - CODE L Manual Actuator - CODE M Printed Circuit Terminals - CODE T 5 Amp contacts (Silver) - CODE Y Coil Voltage AC: 6, 12, 24, 48, 120, 240 (Add "A") DC: 6, 12, 24, 48, 115, 125 (Add "D") - 1 5 2 6 3 7 9 11 10 OPERATE 13 4 8 12 14 + RESET SINGLE COIL DC OPERATED 1 5 2 6 3 7 4 8 9 10 11 12 + - OPERATE COMMON 13 14 RESET SINGLE COIL AC OPERATED Dual Coil Construction available. Consult Factory. PAGE 173 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 MAGNETIC LATCH 10 AMP, 4 POLE RELAY SERIES 308 GENERAL SPECIFICATIONS COIL Pull-in Voltage: Dropout Voltage: Max. allowed voltage: Coil Resistance: AC: 85%, DC: 75% of nominal voltage measured at 25˚C 10% of nominal voltage or more @ 25˚C 110% of nominal voltage ±10% Measured @ 25˚C CONTACTS Contact Material: Silver Cadmium Oxide. TIMING Operate Time: Release Time: AC: 25mS, AC: 25mS, DC: 15mS @ nom. Voltage DC: 15mS @ nom. Voltage DIELECTRIC STRENGTH All Mutually Insulated Points: 500 V rms across open contacts 1500 V rms between current carrying parts Insulation Resistance: 500 VDC Exceeds 1000 Megohms. TEMPERATURE Temperature Rating: LIFE EXPECTANCY Mechanical: Electrical: MISCELLANEOUS Enclosure: Weight: -45˚C to +70˚C @ Rated Operation. 10 Million Operations no load 100,000 Operations @ Rated Load. Clear polycarbonate 5.0 oz. approx.. CONTACT RATINGS LOAD Resistive Motor Load 80% pF. 30VDC 120VAC 240VAC 10A 10A 1/3Hp 10A 1/2Hp Maximum total load for 4 pole relays is 30 Amps @ 120 VAC, 20 Amps @ 240 VAC. COIL SPECIFICATIONS @ 25˚C Nominal Voltage 6 12 24 48 120AC or 115-125DC 240AC* Resistance Resistance Ohms ± 10% Ohms ± 10% DC AC 3 30 12 120 48 480 1920 870 8200 4700 -* Current (MA) AC 560 230 115 31 DC 200 100 50 25 13-15 Power Consumption AC DC 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.2W 3.4VA 1.9W 12 -* 3.4VA 1.9W NOTE: For 220 VDC to 250 VDC coils, use a 8,200 Ω, 5 Watt resistor in series with 110 VDC to 125 VDC relay coils. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 174 SERIES B255 300 VOLT LATCHING PLUG-IN RELAYS THE SERIES B255 IS A TWO COIL LATCHING VERSION OF THE GENERAL PURPOSE TYPE 219 RELAY. WHEN THE OPERATE COIL IS MOMENTARILY ENERGIZED, THE RELAY MECHANICALLY LATCHES IN THE ENERGIZED POSITION AND REMAINS IN THE ENERGIZED POSITION WITH THE POWER REMOVED FROM THECOIL. THE SECOND COIL WHEN MOMENTARLY ENERGIZED, PROVIDES ELECTRICAL RESET OF THE CONTACTS. ALL CONTACTS OPERATE FROM A COMMON ARMATURE TO PREVENT CONTACT OVERLAPPING. COILS ARE RATED FOR CONTINUOUS DUTY. NUCLEAR QUALIFIED VERSIONS ARE AVAILABLE. CONTACT THE FACTORY FOR DETAILS. UL Recognized File No. E13224 R R OUTLINE DIMENSIONS Dimensions shown Inch & (Millimeters) 4.56 (115.8) LOCKING DEVICE PAGE 175 TYPE RESET OPERATE 7 6 RESET 12 1 SEE SECTION 10 FOR MATING SOCKETS B255BXBP (2 N.O. + 2 N.C. ) 1 RESET RESET 12 1 6 OPERATE 6 7 DPDT + 1 NO DPDT 3PDT 2 NO + 2 NC 12 7 B255ABXP (DPDT + 1 N.O. ) SUFFIX U V LM 33 CONTACTS B255ABXP B255XBXP B255XCP B255BXBP B255XCXP (3 PDT) OPERATE OPTIONS 130˚C Coil Coil Suppression Light & Actuator Fine Silver-Gold Diffused Bifurcated Contacts 1 6 Note: For time delay on energizing reset coil, specify 256 series in lieu of B255 DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC) 12 B255XBXP (DPDT ) P LM - Series B255 2 Coil Latch plug-in Contact Arrangements XBX DPDT XCX 3PDT ABX SPST-NO & 2 Form C BXB DPST-NO & 2 Form B Standard Features Polycarbonate Cover- CODE "P" Optional Features Indicator Lamp across both coils - CODE "L" Manual Actuator- CODE "M" Perm. Magnet Blowout- CODE "69" Coil Voltage Coil Voltages & Frequencies must be specified. 1 (VIEWED FROM TERMINAL END) OPERATE B255 XCX 2.625 (66.67) WIRING DIAGRAMS Struthers-Dunn ORDERING CODE Typical Type No. 7 1.468 (37.28) 6 3.75 (95.25) 7 12 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 300 VOLT LATCHING PLUG-IN RELAYS SERIES B255 GENERAL SPECIFICATIONS COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage CONTACTS Contact Material: Silver Cadmium Oxide, & Gold Diffused (Standard) TIMING Operate Time: (operate coil) Release Time: (Reset coil energized) 25 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH All Mutually Insulated Points: Insulation : 1500 V rms 1/4" over surface, 1/8" thru Air TEMPERATURE Rated Operation: -10˚C to +60˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. 500,000 Operations 1/2 Rated Load. MISCELLANEOUS Enclosure: Weight: Clear polycarbonate. 215 g (7.58 oz.) APPROX. UL Recognized File No. E13224 R R COIL SPECIFICATIONS @ 25˚C *AC COIL, 50/60 HZ RESET COIL (3VA) OPERATE COIL (5VA) Nominal Resistance Coil Power Resistance Coil Power Ohms (mA) (mA) Voltage Ohms ± 10% ± 10% 1.10 3.0 6 840 800 4.20 14.5 12 256 410 15.5 52.0 24 150 200 540 1450 120 26.5 45.0 1815 5000 240 4.8 13.2 Current inrush on all AC coils is less than twice the listed milliamperes ratings as shown in the AC coil data table. *Currents shown in table measured at 60 Hz. DC COIL DATA OPERATE COIL (1.8W) Resistance Coil Power Ohms (mA) ± 10% 15.5 385 63.5 189 250 96.0 6200 20.0 DC relays, 1.8 Watts (2.5 W @ 125VDC) RESET COIL 1.4W) Nominal Resistance Coil Power Voltage Ohms (mA) ± 10% 21.0 6 286 85.0 12 141 300 24 80 115/125 8000 14.4 CONTACT RATINGS BREAK MAKE CARRY RESISTIVE INDUCTIVE VOLTS 24 VDC 120 VAC 240 VAC 28 VDC 125 VDC 30A 30A 30A 30A 30A 10A 10A 10A 10A 10A 10A 10A 5A 10A 0.5A 10A 3A 1A 3A 0.1A ** For versions with suffix "69" Permanent Magnet Blowouts 125 VDC 125 VDC 250 VDC 250 VDC SM DM SM DM 30A 30A 30A 30A 10A 10A 10A 10A 1.5A 4A 0.5A 1.5A 0.5A 1.5A 150 mA 0.5A **Relays with Code 69 feature ( Check with factory for UL & CSA Listing). WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 176 CLASS DUAL COIL, 10 AMP LATCHING RELAYS 88L CLASS 88L OPEN STYLE DUAL COIL LATCHING RELAY RATED 10 AMPS OUTLINE DIMENSIONS Dimensions shown Inchs & (Millimeters) 2.87 Max. (72.9) 1.37 Max. (34.8) 1.75 Max. (44.45) NOTE: Applying a momentary pulse to that coil which was NOT LAST ENERGIZED, will cause a transfer of all contacts. The mechanical latch will maintain all contacts in the last transferred position even after the coil is deenergized or power is interrupted. Re-transfer of contacts can be accomplished by a momentary pulse to the other coil. .156 Dia. (3.96) 1.00 Typ. (25.4) 2.37 Max. (60.2) 2.68 Max. (68.07) 1.93 Max, (49.0) .130 (3.30) .100 (2.54) CLASS 88LCP ENCLOSED STYLE DUAL COIL LATCHING RELAY RATED 10 AMPS WIRING DIAGRAMS Shown from Pin End 2.375 (60.3) 3.562 (90.47) 1.75 (44.45) 11 7 9 10 13 8 12 6 14 5 4 15 16 2 20 17 3 18 1 19 20 Pin Octal Socket mates with Magnecraft chassis mount socket 70-454 or equivalent. 5PDT PART NUMBER 70-454, 20 PIN SOCKET AVAILABLE. CALL FACTORY FOR CURRENT QUOTE. PAGE 177 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 DUAL COIL, 10 AMP LATCHING RELAYS CLASS 88L SPECIFICATIONS CLASS 88L RELAYS COIL Pull-in voltage: Coil resistance: Nominal power: Duty: 80% of nominal voltage or less. for DC coils 85% of nominal voltage or less for AC coils 50/60 Hz operation, Measured @ 25˚C ± 10 % measured @ 25 ˚C 6VA for AC coils, 3 Watts for DC coils. Intermittent actuation. min. pulse time 50mS @ nominal voltage. Max. pulse time 2 Minutes for AC coils, 5 Minutes for DC coils. CONTACTS Contact material: Contact resistance: 3/16" silver cadmium oxide, gold flashed. 50 mΩ max. initial resistance @ rated current TIMING Operate time: Release time: 25 mS or less at nominal voltage. 25 mS or less at nominal Voltage. DIELECTRIC STRENGTH Contacts to coil: Across open contacts: Pole to pole Contacts to frame: Insulation resistance: 1500 V rms 1000 V rms 1500 V rms 1500 V rms 1000 megohms min. 500 VDC TEMPERATURE Ambient Temperature (Operating): Non operating (storage): -10˚C to +50˚C (AC), -10˚C to +60˚C (DC) -30˚C to 105˚C SHOCK RESISTANCE Operating: Non operating: 5 G's 20 G's VIBRATION RESISTANCE Operating Non operating: 5 G's, 10 Hz to 55 Hz 5 G's, 10 Hz to 55 Hz MISCELLANEOUS Mounting: Insulation material: Terminals Enclosure: Operating Position: Weight:. 6 holes, 5/32" dia.for mounting plate to flat surface or 20 pin style plug-in. Fiberglass melamine Open style are Solder type standard, will also accept Q.C. terminals size .110. (Amp "Faston" or equivalent) Enclosed styles have 20 nickel plated brass pins "See-through " clear, polycarbonate plastic. Any Open Style: 6-1/2 ozs. 184.3 grams approx.. Enclosed style: 8 ozs. 226.8 grams COIL Measured at 25˚C CROSS REFERENCE CONTACT NOMINAL TO CONFIGU- NOMINAL RESISTANCE NOMINAL POWER POTTER & BRUMFIELD RATION VOLTAGE (OHMS) AC OPERATED, OPEN STYLE, SOLDER TERMINAL _ 4PDT 120 VAC KB-17AG-120 6 VA W88ALX-4 PART NUMBERS DC OPERATED, OPEN STYLE, SOLDER TERMINAL 50Ω 4PDT 12 VDC 88LX-2 AC OPERATED, ENCLOSED 20 PIN OCTAL PLUG-IN _ 120 VAC 5PDT 88ALCPX-23 2.4W KB-17DG-12 6 VA KBP-20AG-120 Stock Part Numbers shown below also available thru stocking distriubution Part Numbers without a "W" prefix are Non-Stock Relays . Other AC & DC coil voltages and contact combinations up to 6 poles are available on special order. Consult Factory WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 178 SERIES INDUSTRIAL PLUG-IN SEQUENCE (STEPPER), 5 AMP A311 The A311 Series Relay is a sequencing version of the 219 series general purpose relay. Contacts transfer on each Impulse to the coil. Models are available with contacts transferring when coil is energized or when de-energized. A double cam movement, one cam per snap switch, allows one or both contacts to be energized or de-energized with the cam rotating one half-step when the coil is energized and the other half step when the coil is de-energized assures reliable sequencing of the two SPDT snap switches. 2.625 (66.6) 2.593 (65.5) 3.406 (86.5) .435 (11) LOCKING CLIP WIRING DIAGRAM Viewed from Pin Side 1 7 12 12 11 10 9 8 7 1 2 3 4 5 6 OPERATE 6 A311XBXP A311XBXPR * (DPDT ) CONTACT RATINGS LOAD 120VAC Resistive Max. Inrush 5A 12A ORDERING CODE Typical Type No. 30VDC 115VDC 5A 12A 0.1A 0.25A GENERAL SPECIFICATIONS 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage Silver Cadmium Oxide TIMING Operate Time: (operate coil) 35 mS Max. @ Nominal Voltage. Release Time: (Reset coil energized) 35 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open Contacts: Between mutually insulated current carrying parts & those parts to ground: Insulation Resistance : 500 V rms 1500 V rms 1000 MΩ min. @ 500 VDC Struthers-Dunn TEMPERATURE Rated Operation: -10˚C to +60˚C A311 XBX P R L -120A LIFE EXPECTANCY Mechanical: Electrical: 5 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear polycarbonate. 190 g (6.70 oz.) approx. Series A311 Industrial plug-in , Sequence Relay, 5 Amp, DPDT Contact Arrangements XBX ( 2 Form C) Standard Features Plug-in with Polycarbonate Cover - CODE P Contact Transfer When coil is energized - NO CODE when coil is de-energized CODE R Options Indicator Lamp - CODE L Coil Suppression - CODE V Coil Voltage AC: 6, 12, 24, 120, 240 (Add "A") DC: 6, 12, 24, 48, 110-125 (Add "D") SEE SECTION 10 FOR MATING SOCKETS PAGE 179 UL Recognized File No. E7104 COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: *Transfer on Release 1.468 (37.2) COIL SPECIFICATIONS @ 25˚C AC COIL , 50/60Hz Nominal Resistance Voltage Ohms ± 10% 1.1 6 4.2 12 15.5 24 540 120 1815 240 DC COIL Nominal Voltage 6 12 24 48 110-125 Resistance Ohms ± 10% 15.5 63.5 250 970 6200 NOTE: Relays with other coil characteristics may be supplied to meet specific application requirements. 250VDC operation may be obtained by wiring a 6,200 Ω, 5 Watt resistor in series with the 110-125VDC coil. The resistor must be mounted external to the A311. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES SCREW TERMINAL SEQUENCE RELAY, 20 AMP, 2 POLE C85 The C85 Series Relay is a base mounted, screw terminal, open style sequencing relay. This two pole relay has a single coil which operates a ratchet wheel. Control cams, on the ratchet wheel shaft, step from one position to the next on each Impulse to the coil. A 50 millisecond pulse will step the relay. Coils are for momentary duty only. The C85 may be supplied in any sequence up to 12 steps. Contacts are single throw. 5.00 (127) 3.00 (76.2) 2.62 (66.5) WIRING DIAGRAM 2.37 (60.1) .312 (7.92) 4.37 (110.9) .312 (7.92) GENERAL SPECIFICATIONS COIL Pull-in, min. AC Pull-in min. DC Overvoltage, max. CONTACTS Contact Material: 85% of Nominal Voltage 80 % of Nominal Voltage 110% of nominal, voltage Fine Silver TIMING Operate Time: (operate coil) 50 mS Max. @ Nominal Voltage. Release Time: (Reset coil energized) 50 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open Contacts: Between mutually insulated current carrying parts & those parts to ground: Insulation Resistance : STANDARD CONTACT SEQUENCES 1500 V rms 1500 V rms 1000 MΩ min. @ 500 VDC TEMPERATURE Rated Operation: -45˚C to +65˚C LIFE EXPECTANCY Mechanical: Electrical: 500,000 Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Terminals: Mounting: Weight RELAY STEP CONTACT A C85AXA CONTACT B CONTACT A C85BXX CONTACT B 0 = CONTACT OPEN # 10-32 Studs with Hardware 3 clearance holes for # 8 screws 325 g (11.46 oz.) Struthers-Dunn ORDERING CODE Typical Type No. CONTACT RATINGS C85 AC DC 24VAC 20A 20A 120VAC 240VAC 20A 1.0A 10A 0.25A COIL SPECIFICATIONS @ 25˚C AC COIL , 50/60Hz Nominal Resistance Voltage Ohms ± 10% 27 24 771 120 110-125 3,290 240 14,700 440 22,000 550 DC COIL Resistance Ohms ± 10% 62 24 120 110-125 1,475 6,100 240 440 550 Nominal Voltage 1 2 3 4 (REPEAT) 0 X 0 X X 0 X 0 0 X 0 X 0 X 0 X X = CONTACT CLOSED C85 AXA H3 -120A Series C85 Screw Terminal Sequence Relay, 20 Amp, 2 Pole Contact Arrangements AXA 1 S.B.-N.O. & 1 S.B.-N.C. BXX 2 S.B.-N.O. Options Open style construction - NO CODE Sheet Metal Housing (consult Factory) For Dimensions) -CODE H3 7, 9, 10, 11, 12 Tooth ratchet-Consult Factory Coil Voltage AC: 24, 120, 240, 440, 550 (Add "A") DC: 24,110-125, 240 (Add "D") RATCHETS: 8 Tooth Standard. ( 7, 9, 10, 11, and 12 are Special Order). Consult Factory. Non-Standard Coils, Specify requirement, Consult Factory. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 180 S E C T I O N 8 8 HIGH VOLTAGE ELECTROMECHANICAL AND REED RELAYS 5KV TO 10KV Page 181 Magnecraft Struthers-Dunn HI-VOLTAGE RELAYS 5KV TO 10KV 158 RELAY SERIES 102V 102HV 5000 V0LTS 5000 V0LTS FEATURES SWITCHES LOADS UP TO 1KVA. @ 5000 VOLTS DESIGNED WITH A UNIQUE DOUBLE MAKE & BREAK CONTACT DESIGN WITH GAP OF 0.40". EXCELLENT HIGH VOLTAGE ARCOVER RESISTANCE BETWEEN CONTACTS. SOLDER TERMINAL DESIGN. 10,000 V0LTS EPOXY SEALED FOR EXTRA PROTECTION FROM HIGH VOLTAGE ARC- OVER EPOXY SEALED FOR EXTRA PROTECTION FROM HIGH VOLTAGE ARC OVER CHASSIS MOUNTING WITH SOLDER TERMINALS. CHASSIS MOUNTING WITH SOLDER TERMINALS. EXTRA WIDE SEPARATION BETWEEN COIL AND OUTPUT CONTACTS. EXTRA WIDE SEPARATION BETWEEN COIL AND OUTPUT CONTACTS. SWITCHES UP TO 10 MILLIAMP SWITCHES UP TO 5 MILLIAMP LOADS @ 10,000 V LOADS @ 5000 V CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CAPACITANCE (No shield) Across open contacts: CONTACT MATERIAL: CONTACT RESISTANCE: SPST-NO SPDT-DB-DM 1 KVA, 5000 VDC 200 mA, 5000 V 1 Amp, 1000 V SILVER ALLOY GOLD FLASHED 100 MILLIOHMS (INITIAL) SPST-NO 50VA, 5000 VDC 10 mA 50VA, 10,000 VDC 5 mA 2.0 pf TUNGSTEN 2.0 pf TUNGSTEN 200 MILLIOHMS (INITIAL) 200 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH Across open contacts: 7,500 V rms & contacts to ground 6,000 VDC 12,000VDC 6,000 VDC 12,000 VDC NOT AVAILABLE 6, 12, 24 VDC 500-580 mW NOT AVAILABLE 24 VDC 1.5 WATTS 3,000 V rms Coil to ground: Between all mutually insulated points: 8,500 V rms COIL DATA AC - VOLTAGE: DC - VOLTAGE: WATTS,: (VDC) AVAILABLE 24 VDC 5 WATTS GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: STORAGE TIMING OPERATE: RELEASE: BOUNCE: SHOCK (Non-operating): VIBRATION: LIFE MECHANICAL: ELECTRICAL: DIMENSIONS - 40˚C to + 85˚ C - 40˚C to + 85˚C (1 Form A) - 40˚C to + 40˚C (1 Form B) -60˚C to + 105˚C - 40˚C to + 85˚ C 10 G's -11mS, 1/2 sinewave 10 G'S - 10 to 55 HZ 3 MILLISECONDS 2 MILLISECONDS 2.0 MILLISECONDS 30 G's -11mS 1/2 sinewave 10 G's - 10 to 1000 HZ 3 MILLISECONDS 2 MILLISECONDS 2 MILLISECONDS 30 G's - 11mS, 1/2 sinewave 10 G's -10 to 1000 HZ 5 MILLION OPERATIONS 100,000 OPERATIONS 10 MILLION OPERATIONS 1,000,000 OPERATIONS 10 MILLION OPERATIONS 1,000,000 OPERATIONS -60˚C to + 105˚C 45 MILLISECONDS 20 MILLISECONDS H W L H W L 2.28 X 2.21 X 3.12 0.75 X .875 X 4.50 PAGE 183 PAGE 184 -60˚C to + 105˚C H W L 0.75 X .875 X .450 APPROVALS PAGE NUMBER PAGE 184 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 182 CLASS 158 HIGH VOLTAGE SWITCHING RELAYS CLASS 158 SPDT-DB-DM CONTACT CONFIGURATION SWITCHES LOADS UP TO 1KVA SPECIFICATIONS CLASS 158 COIL Coil Dissipation: DC 5 Watts. CONTACTS Contact Material: Silver alloy, Gold Flashed, 1/4" dia. Contact Configuration: SPDT-DB-DM Switching Voltage max.: 5000 VDC Contact Rating: OUTLINE DIMENSIONS DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS) 1.750 (44.45) .196 ( 4.98) dia. 2 Holes 1.125 (28.58) 200 mA @ 5000 VDC 1 Amp @ 1000 VDC DIELECTRIC STRENGTH Across open contacts: Contact to Coil: Contact to Frame: Insulation Resistance: 7500 V rms 8500 V rms 3000 V rms 500 VDC, Exceeds 100 MΩ TEMPERATURE Operating: -40˚C to +85˚C LIFE EXPECTANCY Electrical: Mechanical: 100,000 ( Rated Load) 5 Million Operations (No Load) Min. MISCELLANEOUS Mounting: Weight: Bracket with 2 Clearance holes 0.196 dia. 212.6 grams (7.48 oz.) 3.125 Max. (79.38) WIRING DIAGRAM VIEWED FROM PIN END FIELD INSTALLABLE JUMPER WIRE 2.281 (57.94) 2.281 (56.34) SPDT-DB-DM PART NUMBERS W158HVX-1 SPDT Coil Measured at 25˚C CONTACT NOMINAL CONFIGURA- NOMINAL NOMINAL INPUT COIL TION VOLTAGE RESISTANCE POWER SPDT-DB-DM 24VDC 120 5 Watts PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. PAGE 183 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS HIGH VOLTAGE SWITCHING RELAYS 102V CLASS 102V EPOXY ENCAPSULATED HIGH VOLTAGE REED. SPST-NO TUNGSTEN CONTACTS SWITCHES LOADS UP 10 mA @ 5000 Volts DC CLASS 102HV Same as above except: Switches 10,000 Volts with Loads up to 5 mA DC OUTLINE DIMENSIONS DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS) 4.50 (114.3) 4.12 (104.7) 0.875 (22.2) 3.40 (86.5) .156 dia. (3.9) 0.75 (19.0) .645 (16.3) 0.25 (6.35) 1.50 (38.1) 1.10 (27.9) Coil Terminals .125 x .025 .125 0.28 (3.18) (7.1) 0.08 (2.03) DIA. Typical. Do not hook wire heavier than #22 AWG. Excess stress on terminals could cause damage to internal components PART NUMBERS CONTACT NOMINAL CONFIGURAINPUT TION VOLTAGE Coil Measured at 25˚C NOMINAL NOMINAL COIL POWER RESISTANCE 5,000 VOLTS NORMALLY OPEN 500 mW 70 Ω W102VX-49 SPST-NO 6 VDC 580 mW 250 Ω W102VX-50 SPST-NO 12 VDC 580 mW 1000 Ω W102VX-51 SPST-NO 24 VDC 10,000 VOLTS NORMALLY OPEN 1.5 Watts 400 Ω W102HVX-3 SPST-NO 24 VDC PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. NOTE: Other voltages and contact combinations available. Contact Factory. Pull-in is measured at 75% of nominal voltage or less, at 25˚C Weight: 49.2 grams, (1.74 oz.) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 184 S E C T I O N 9 9 SENSITIVE LOW INPUT POWER RELAYS 2 TO 5 AMPERES Page 185 Magnecraft Struthers-Dunn SENSITIVE RELAYS 2 TO 5 AMP RELAY SERIES FEATURES 112, 112PGF 67S LOW POWER DESIGN REQUIRES AS LITTLE AS 11.4 mW or 51.7 mW OF DC COIL POWER. SOLDER/PLUG-IN WITH A 3-38 UNC MOUNTING STUD. AVAILABLE WITH AC OR DC COILS. UP TO 4 POLES WITH STANDARD SILVER, GOLD OVERLAY CONTACTS CAN WITHSTAND 5 TO 10 TIMES COIL RATING UP TO 300 VOLTS 219 STYLE PLUG-IN OR OPEN STYLE CHASSIS OR PC STYLE SOCKETS. 292 392 LOW POWER DC RELAY 125mW PER POLE. LOW POWER DC RELAY 125 mW PER POLE OPERATES OVER A 3 WAY SOLDER TERMIWIDE VOLTAGE RANGE. NALS, .187 Q.C./ PLUG-IN. OCTAL STYLE PLUG-IN OPERATES OVER A FITS STANDARD 8 OR 11 WIDE VOLTAGE RANGE. PIN OCTAL SOCKETS FITS STANDARD 283/388 STANDARD SOCKETS. INDUSTRY STANDARD FOOTPRINTS. CONTACT DATA CONTACT CONFIGURATION: MAXIMUM ALLOWABLE CONTACT LOAD: CONTACT CONTACT MATERIAL: RESISTANCE: SPDT, DPDT SPDT TO 4PDT 2Amps @ 120 VAC 1 Amp @ 240 VAC 2 Amps @ 30 VDC FINE SILVER 3 AMP @ 120 VAC/30 VDC 50 MILLIOHMS (INITIAL) SPDT TO 3PDT 5 Amps @ 120 VAC/30 VDC 5 Amps @ 120/240 VAC, 28 VDC SILVER SILVER SILVER, GOLD OVERLAY 50 MILLIOHMS (INITIAL) SPDT TO DPDT 50 MILLIOHMS (INITIAL) 50 MILLIOHMS (INITIAL) INSULATION CHARACTERISTICS DIELECTRIC STRENGTH Across open contacts: Between all mutually insulated current carrying parts and those parts to ground: 500 V rms 500 V rms 500 V rms 500 V rms 1,500 V rms 1,500 V rms 1,500 V rms 1,500 V rms 1.0 to 225 0.08 to 21.0 mA NOT AVAILABLE 4.5 to 13.7 mA NOT AVAILABLE 15 to 139 mA 11.1 to 35 mA NOT AVAILABLE 15 to 139 mA 11.1 to 35 mA 1 pole 0.2VA, 2 pole 1.0VA 1 pole 15mW, 2 pole 52mW 85 to 200 mW 125 mW Per pole 125 mW Per pole COIL DATA AC - VOLTAGE: DC - CURRENT: POWER AC VA: MILLIWATTS DC: GENERAL DATA AMBIENT TEMPERATURE OPERATIONAL: TIMING OPERATE: RELEASE: LIFE MECHANICAL: ELECTRICAL: OPTIONS: DIMENSIONS - 45˚C to + 65˚ C 20 MILLISECONDS 20 MILLISECONDS 500,000 OPERATIONS 100,000 OPERATIONS Special Pick-up and Dropout adjustments. Series coils to 50 Amp. H W L 3.62 X 1.46X 2.62 - 55˚ C to + 70˚ C 18 MILLISECONDS 8 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS Up to 8PDT @ 50 mW per pole. P.C. Terminals, Bifurcated contacts. Epoxy H W L .735 X .1.158 X 1.20 - 45˚C to +70˚ C 20 MILLISECONDS 15 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS Indicator lamp (125 VDC only) Manual Actuator. H W - 45˚C to + 70˚ C 20 MILLISECONDS 15 MILLISECONDS 10 MILLION OPERATIONS 100,000 OPERATIONS Indicator lamp (125 VDC only) Manual Actuator. P.C. socket, Q.C. socket. Stud or bracket mount. Gold diffused contacts. L 2.81 X .1.37 X 1.37 H W L 2.813 X 1.37 X 1.37 APPROVALS PAGE NUMBER PAGE 187, 188 PAGE 189 PAGE 190 PAGE 191, 192 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 186 SERIES 112, 112-PGF 2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN The 112 and 112-PGF Series of very low coil power relays, perform the same function but differ in physical packaging and terminations. Each is available with SPDT or DPDT contact arrangements. The coils require as little as 11.4 mW or 51.7 mW of DC coil power respectively. All 112's are available with AC or DC coils. AC coils can withstand 5 times their minimum rating, while DC coils can withstand 10 times their minimum rating, up to 300 volts. One application for this relay is to detect high resistance grounds which could have low leakage current. OUTLINE DIMENSIONS WIRING DIAGRAMS Viewed from Pin end Dimensions are shown in INCHES and (MILLIMETERS) Removable cover with top screw for field adjustment of pull-in. 112XAX-PGF (SPDT ) 2.625 (66.6) 6 1 7 12 2.593 (65.5) 3.406 (86.5) 112XBX-PGF (DPDT) 6 1 7 12 .435 (11) LOCKING CLIP 12 11 10 9 8 7 1 2 3 4 5 6 1.468 (37.2) 112-PGF Relays have front removable covers. When cover is removed the relay can be adjusted without being plugged in. 0.10 Dia. x .435 (2.54 x 11) Typical of all Pin Dimensions Struthers-Dunn ORDERING CODE Typical Type No. 112 XBX PGF Specify Coil separately Series A112 base mounted, low coil power, 1 Form "C" 112 Low coil power, 1 & 2 Form "C" plug-in , 2 Form "C" base mount. Contact Arrangements XAX-SPDT (use with A112 base mount or 112-PGF) XBX - DPDT AXX SPST-NO (use with A112 base mount or 112-PGF BXX- DPST-NO AXA - SPST-NO +SPST-NC Construction Style Base mounted open style - NO CODE Industrial Plug-in, Polycarbonate cover, front removable - CODE PGF Coil Voltage Because of the wide variety of coils, both voltage and current to choose from, specify as a separate item. OPTIONS (CONSULT FACTORY) PAGE 187 DIMENSIONS & WIRING DIAGRAMS Front View A112XAXBase mounted open style (SPDT ) A112XBXBase mounted open style (DPDT ) 2.125 (53.97) 1.875 (47.62) 1.375 (34.92) 2.125 (53.97) 2.625 (66.67) 2.625 (66.67) .625 (15.87) 2.375 (60.32) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES 2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN 112, 112-PGF GENERAL SPECIFICATIONS 112, 112-PGF COIL Overvoltage, max. AC, 5 x min. voltage, DC, 10 x min. voltage (up to 300V) CONTACTS Contact Material: Fine Silver TIMING Operate Time: Release Time: 20 mS Max. @ Nominal Voltage. 20 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open contacts: All Mutually Insulated current carrying parts to ground: -45˚C to +65˚C LIFE EXPECTANCY Mechanical: Electrical: 500,000 Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear polycarbonate. (112-PGF Only) 7.05 oz. (200 g) approx. OPERATING DATA: (All Types) CONTACT RATINGS AC DC 30VDC 2A 2A 1500 V rms TEMPERATURE Rated Operation: Approvals for A112XAX & XBX Only. UL Recognized File No. E7104 LOAD 500 V rms Min. Voltage: Selected from coil tables Min. Current: Selected from coil tables Series Coils: Available for connection in series with loads up to 50 Amps for series 112, and 10 Amps for series 112-PGF. 120VAC 240VAC 2A 0.25A 2A - COIL SPECIFICATIONS Measured @ 25˚C TYPES A112XAX, 112XAXPGF AC COILS, 50/60 HZ Minimum Minimum Impedance Voltage Milliamps Ohms 1.0 1.4 1.6 2.0 2.5 3.5 4.3 5.0 6.0 8.5 12.0 13.5 16. 20 23 33 43 55 67 87 103 130 146 168 225 177 143 116 91.0 74.0 52.5 41.5 38.0 31.5 23.0 19.0 15.7 11.8 9.65 7.65 6.00 4.66 3.85 2.98 2.25 1.93 1.53 1.22 0.95 0.74 6 9 13 22 34 60 100 130 190 370 630 860 1,350 2,070 3,000 6,500 9,230 14,300 22,500 38,500 53,000 85,000 120,600 177,000 300,000 TYPES 112XBX, 112XBXPGF DC COILS Minimum Minimum Resistance Voltage Milliamps Ohms 0.08 0.10 0.12 0.15 0.19 0.25 0.30 0.39 0.49 0.62 0.78 0.95 1.30 1.60 2.00 2.50 3.20 3.90 4.80 6.40 8.00 9.70 11.7 16.0 21.0 145 117 95.0 73.0 60.0 43.0 33.0 31.0 26.0 18.8 15.5 12.8 9.70 7.90 6.30 4.90 3.80 3.15 2.43 1.84 1.58 1.25 1.00 0.84 0.61 0.55 0.84 1.26 2.10 3.10 5.80 9.00 12.5 19.0 33.0 50.0 74.0 129 197 312 504 840 1,220 1,990 3,450 5,050 7,700 11,700 19,000 34,000 AC COILS, 50/60 HZ Minimum Minimum Impedance Ohms Voltage Milliamps 2.34 2.80 3.25 4.40 5.50 6.90 9.10 10.8 13.1 20.6 26.5 30.0 35.0 45.5 49.0 72.0 95.0 122 146 190 230 390 310 250 200 160 114 910 83.0 69.0 50.0 42.0 35.0 26.0 22.0 16.4 13.0 10.2 8.5 6.5 4.9 4.9 6 9 13 22 34 60 100 130 190 370 630 860 1,350 2,070 3,000 6,500 9,230 14,300 22,500 38,500 53,000 DC COILS Minimum Minimum Resistance Voltage Milliamps Ohms 0.18 0.22 0.27 0.34 0.41 0.55 0.68 0.86 1.09 1.37 1.72 2.11 2.77 3.46 4.33 5.47 7.11 8.53 10.8 14.1 17.7 323 260 211 165 133 95.0 76.0 69.0 57.0 42.0 35.0 29.0 22.0 18.0 14.0 11.0 8.5 7.0 5.5 4.0 3.5 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 0.55 0.84 1.26 2.10 3.10 5.80 9.00 12.5 19.0 33.0 50.0 74.0 1219 197 312 504 840 1,220 1,990 3,450 5,050 PAGE 188 CLASS 3 AMP, LOW COIL POWER, 2 & 4 POLE PLUG-IN 67S UL RECOGNIZED FILE NO. E52197 TYPICAL CONTACT LIFE EXPECTANCY FOR SWITCHING RESISTIVE LOADS @ 25˚C Number of Operations Load Current Load Voltage 1.0A 0.5A 0.1A 1mA CLASS 67 TYPICAL TIMING VALUES Ultra sensitive 5 X 105 5 X 106 5 X 107 5 X 107 - 28VDC/120VAC 28VDC/120VAC 6 VDC 6 VDC POLES DPDT 4PDT OPERATE TIME 012 .014 RELEASE TIME .008 .008 Measured at Nominal Voltage @ 25˚C Tolerances ± .010 Inches DIMENSIONS "A" CONTACT CONFIGURATION "A" DPDT .978 (24.8) 4PDT 1.156 (29.4) 1.20 Max. (30.3) DIM. .200 Max. (5.1) 3-48UNC-2A Thd. .094 (2.3) .170 (4.3) Elongated Hole .100 x .040 ( 2 x .1) All Contact Terminals are .010 Thick all coil terminals are .018 Thick. SPECIFICATIONS CLASS 67S COIL Pickup voltage: Dropout voltage: Coil resistance: Maximum coil dissipation: Coil Temperature rise: Maximum coil temperature: CONTACTS Contact material: Contact resistance: CAPACITANCE Between contacts: Contact to coil: Coil to frame: 80% of nominal voltage or less. 10% of nominal or more. ± 10% measured @ 25˚C 2.2 watts @ 25˚C 30˚C per watt 105˚C Silver, Gold overlay 50 milliohms max. initial 2 pf, typ. 2 pf, typ. 30 pf, typ. DIELECTRIC STRENGTH Contact to coil: Across open contacts: Coil to frame: Contacts to frame: Insulation resistance: 1500 V rms 500 V rms 1000 V rms 1500 V rms 1000 megohms @ 25˚C & 50% R.H. TEMPERATURE Operating: Storage: -55˚C to + 70˚C -55˚C to +105˚C MISCELLANEOUS Enclosure Material: Operating Position: Mounting: Weight: Polycarbonate see thru plastic cover. Any Socket or 3-48 UNC stud 0.77 to 1.4 oz. (22 to 40 grams) CLASS 67 - DC OPERATED - ULTRA SENSITIVE - PLUG-IN STYLE WITH 3-48 UNC STUD. COIL Measured @ 25˚C CROSS REFERENCE CONTACT TO NOMINAL PULL-IN CONFIGU- POTTER & BRUMFIELD PULL-IN PART NUMBERS CONTACT NOMINAL INPUT RESISTANCE RATION MILLIAMPS DC WATTS RATING MILLIAMPS DC (OHMS) STANDARD CONTACTS W67SCSX-1 W67SCSX-2 W67SCSX-3 W67SCSX-6 W67SCSX-7 W67SCSX-8 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 3 AMPS 9.4 mADC 6.4 mADC 4.5 mADC 13.7 mADC 9.1 mADC 6.5 mADC 1000 2500 5000 1000 2500 5000 9.2 mADC 6.3 mADC 4.4 mADC 13.5 mADC 8.9 mADC 6.3 mADC 85mW 100mW 100mW 200mW 200mW 200mW DPDT DPDT DPDT 4PDT 4PDT 4PDT R10SE1(X or Y)2-J1.0K R10SE1(X or Y)2-J2.5K R10SE1(X or Y)2-J5.0K R10SE1(X or Y)4-J1.0K R10SE1(X or Y)4-J2.5K R10SE1(X or Y)4-J5.0K Part numbers shown also available thru Stocking Distribution. SEE SECTION 10 FOR MATING SOCKETS PAGE 189 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 SERIES SENSITIVE PLUG-IN, 5 AMP, 1 - 3 POLES 392 The 392 series relay has been designed to operate at 125 Milliwatts per pole. Because of the coil sensitivity, the contacts are rated at 5 Amps. The Industry standard 8 pin octal plug is used with SPDT & DPDT contact configurations, and the 11 pin plug is used with 3PDT contact configurations. Silver contacts are standard on this 5 Amp Relay. OUTLINE DIMENSIONS Dimensions are shown in INCHES and (MILLIMETERS). 2.25 (57.1) .40 (10.1) 1.37 (34.9) .675 (17.1) 4 5 3 6 2 7 1 1.37 (34.9) 8 WIRING DIAGRAM UL Recognized File No. E13224 VIEWED FROM PIN END CONTACT RATINGS LOAD 30VDC 120VAC Resistive 5A 5A GENERAL SPECIFICATIONS 392 CONTACTS Contact Material: Silver TIMING Operate Time: Release Time: 20 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage. SPDT DPDT DIELECTRIC STRENGTH Across open contacts: 500 V rms All Mutually Insulated current carrying parts to ground: 1500 V rms Insulation Resistance: 1000 Megohms min. 500 V TEMPERATURE Rated Operation: -45˚C to +70˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight; Clear polycarbonate 3-1/2 oz. (99.2 g approx.). COIL SPECIFICATIONS @ 25˚C DPDT Resistance SPDT 392XBX (Ohms) 392XAX mA Volts mA Volts 1,000 2,500 5,000 10,000 11.1 15-44 15.8 21-44 7.0 23-68 10.0 32-68 5.0 32-97 7.0 45-97 3.5 45-139 5.0 64-139 Struthers-Dunn ORDERING CODE Typical Type No. 3PDT 392XCX mA Volts 19.3 25-44 12.0 39-68 8.5 55-97 6.0 77-139 NOTES: (1) Rates for continuous operation at 25˚C at voltages within listed ranges. (2) Must operate at min. currents listed. Specify current when ordering POWER CONSUMPTION: 125mW per pole @ currents listed in the coil table. 3PDT 392 XBX 48P LM - 5.0M Series Series 392 enclosed plug-in, low power consumtion coil. Open Style (Consult Factory) Contact Arrangements XAX- SPDT XBX - DPDT XCX - 3PDT Construction Style Open Style: ( Consult Factory for mounting styles, special wiring etc.). Enclosed Plug-in - CODE 48P Options Indicator Lamp, (125 VDC coil only.see coil specifications) - CODE L Manual Actuator - CODE M Operating Current (DC Only) XAX: 11.1, 7.0, 5.0, 3.5 (Add M) XBX: 15.8, 10.0, 7.0, 5.0 (Add M) XCX: 19.3, 12.0, 8.5, 6.0 (Add M) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 190 SERIES SENSITIVE , 3-WAY TERMINALS, 5 AMP, 1 - 3 POLES 292 The 292 series relay has been designed to operate on 125 MILLIWATTS per pole. Because of this coil sensitivity, the contacts are rated at 5 Amps. The 3-way terminal design provides additional versatility in wiring. The 1 to 3 Form "C" contact configurations, are ideal for low current DC circuits that require up to a 5 Amp outputs. Silver contacts are standard on this 5 Amp Relay. R UL Recognized File No. E13224 OUTLINE DIMENSIONS Dimensions shown are in INCHES and (MILLIMETERS) 2.90Max. (73.8) .187 x .020 (4.76 x 0.51) QC Terminals Typical 2.50 (63.5) WIRING DIAGRAM Viewed from terminal end 1.53 Max. .625 Typ.(38.8) (15.8) Top mount plate & Stud Manual Push Button .218 Actuator (5.56) .156 (3.9) 1 4 2 5 3 6 7 8 9 A ENCLOSED BRACKET MOUNT The Body dimensions for the Enclosed style Plug-in are the same as the Bracket Mount style. GENERAL SPECIFICATIONS Silver TIMING Operate Time: Release Time: 20 mS Max. @ Nominal Voltage. 15 mS Max. @ Nominal Voltage. DIELECTRIC STRENGTH Across open contacts: 500 V rms All Mutually Insulated current carrying parts to ground: 1500 V rms Insulation Resistance: 1000 Megohms min. 500 V TEMPERATURE Rated Operation: -45˚C to +70˚C LIFE EXPECTANCY Mechanical: Electrical: 10 Million Operations no load 100,000 Operations @ Rated Load. MISCELLANEOUS Enclosure: Weight: Clear polycarbonate. 3 oz. (85.05 g) approx.. COIL SPECIFICATIONS @ 25˚C 1,000 2,500 5,000 10,000 DPDT 392XBX mA Volts 11.1 15-44 15.8 21-44 7.0 23-68 10.0 32-68 5.0 32-97 7.0 45-97 3.5 45-139 5.0 64-139 3PDT 392XCX mA Volts 19.3 25-44 12.0 39-68 8.5 55-97 6.0 77-139 NOTES: (1) Rates for continuous operation at 25˚C at voltages within listed ranges. (2) Must operate at min. currents listed. Specify current when ordering POWER CONSUMPTION: 125mW per pole @ currents listed in the coil table. PAGE 191 1 4 2 5 3 6 7 8 9 7 8 9 B A B DPDT SPDT 292XBX 292XAX B .28 Typ. (7.1) 1 4 2 5 3 6 7 8 9 B A 3PDT CONTACT RATINGS LOAD 30VDC 120VAC 240VAC Resistive CONTACTS Contact Material: SPDT 392XACX mA Volts 3 6 292XCX Struthers-Dunn Resistance (Ohms) 2 5 A 1.90Max. (48.4) 1.40Max. (35.5) ENCLOSED STYLE Choice of 6-32 Stud or Tapped Core with anti-rotation tab. - OR 6-32 Stud with top mounting plate and 1/8" nominal length anti rotation tab. 1 4 ORDERING CODE Typical Type No. 5A 5A 5A 292 XBX CS1 L - 10D Series Series 292 , 3-Way Terminals 125 Milliwatts per pole. Contact Arrangements XAX- SPDT (1 Form C) XBX - DPDT (2 Form C) XCX - 3PDT ( 2 Form C) Construction Style Open Style ( Consult Factory for mounting styles, special wiring etc.) Enclosed Plug-in - CODE C Enclosed Bracket Mount - CODE C1 Enclosed with 6-32 Side tapped hole- CODE C2 Enclosed Bracket Mount - CODE C! Enclosed with 6-32 side stud - CODE CS2 Options Gold Diffused Contacts - CODE G Indicator Lamp (125VDC Only) -CODE L Manual Actuator - CODE M Printed Circuit Terminals - CODE T Coil Current (DC Milliamps Only). XAX: 11.1, 7.0, 5.0, 3.5 (Add M) XBX: 15.8, 10.0, 7.0, 5.0 (Add mA) XCX: 19.3, 12.0, 8.5, 6.0 (Add mA) SEE SECTION 10 FOR MATING SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 S E C T I O N 10 10 SOCKETS AND ACCESS0RIES Page 192 Magnecraft Struthers-Dunn SOCKET SELECTION GUIDE FEATURES Octal base, 8 or 11 Pin socket. Panel or DIN rail mount with Screw Terminals & pressure plates. Fits all standard 8 & 11 pin octal plugs. 70-464-1 8 250 314 70-465-1 11 Screw UL CSA None Yes Yes Yes None Yes Yes Yes APPROVALS: PAGE CE NO. 195 Yes Yes Yes No 16-1197 Yes Yes Yes Solder Solder Chassis Chassis No No 16-1197 16-1197 Yes Yes Yes Yes Yes Yes 1, 2 4 P.C. P.C. P.C. P.C. No No 16-1197 16-1197 Yes Yes Yes Yes Yes Yes 198 235, 236, 388 1, 2 3 Screw Panel or DIN Mount No 16-1278 or 16-1239 Long Body Yes Yes Yes 199 235, 236, or 388, 1, 2 or 3 Solder, Chassis 3/16" Q.C. Chassis P.C. PC P.C. P.C. No No No No 16-722-2 16-722-2 16-722-2 16-722-2 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 200 4 Screw 78R 78 1, 2 4 8 14 78R 78 70-463-1 11 70-124-1 70-124-2 70-178-1 70-178-2 11 70-401-1 70-378-1 8 14 70-402-1 70-379-1 Class 388 & 283 Square Base 11 pin Panel/DIN rail Mount, with Screw Terminals. Class 388 & 283 Square Base Socket for blade style relays. Solder/ Plug-in, Quick connect or Printed Circuit terminals. P.C. Socket without mounting ears 70-178-2 12 Panel or Not DIN Required Mount CLIP PART NO. 16-1197 78 27390 HOLDDOWN CLIP INCLUDED No 14 Class 76 Panel or DIN mount Socket. Screw Terminals with pressure plates 3 MOUNTING Panel or DIN Mt. Panel or DIN Mt. 70-461-1 219 Style Front connected wiring on one level with Screw Terminals. Mating relays have Locking Clip that mates with clip receiver in socket. All Sockets are supplied with insulated backing plate. Fits 14 pin 219 style relays. Screw Screw 8 219 Style Front connected wiring on one level with Screw Terminals. Mating relays have Locking Clip that mates with clip receiver in socket. All Sockets are supplied with insulated backing plate. Fits 12 pin 219 style relays. 1, 2 1, 2 78R 70-459-1 Class 78 Panel Mount/DIN rail mount with screw Terminals, Chassis mount with solder terminals or P.C. mount for direct solder to P.C. board. PAGE 193 USE SOCKET NO. SOCKET NO. OF TERMINAL PART WITH OF NO. TYPES PINS RELAY POLES 219 T219 246, 247 B255, A311 349, 112-PGF RSX1800 101-112 RRX164 33377 14 219 14 Pin Versions 70-478-1 70-475-1 5 8 76EU 196 197 2 to 5 Pole Screw Panel No None Yes 201 2 to 6 Pole Screw Panel No None Yes 201 Panel or Din rail No 16-1264 1 2 Screw Yes Yes WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 202 Magnecraft Struthers-Dunn SOCKET SELECTION GUIDE FEATURES USE NO. OF TERMINAL SOCKET NO. PART OF SOCKET POLES TYPES NO. PINS WITH RELAY Class 67 Chassis Mount Socket has Solder terminals. 70-303-1 70-304-1 70-305-1 Printed Circuit Socket 70-306-1 pins are soldered directly to the P.C.Board. 70-307-1 All sockets have relay 70-308-1 grounding strip that 70-309-1 connects to stud on 70-310-1 plug-in style relays. 10 10 16 16 22 22 28 28 67 2 2 4 4 6 6 8 8 Solder P.C. Solder P.C. Solder P.C. Solder P.C. Class 97 Chassis Mount Socket with metal mounting flange. 70-312 10 97 2 Solder DIP P.C. style 14 Pin Socket. Fits 0.100 board spacing. 70-276 14 DIP 1 or 2 P.C. MOUNTING HOLDDOWN CLIP INCLUDED Chassis P.C. Chassis P.C. Chassis P.C. Chassis P.C. Yes Yes Yes Yes Yes Yes Yes Yes CLIP PART NO. 16-875-1 16-875-1 16-875-2 16-875-2 16-875-3 16-875-3 16-1120-8 16-1120-8 APPROVALS: UL CSA CE No No No No No No No No No No No No No No No No No No No No No No No No PAGE NO. 203 204 Chassis No None No No No 205 P.C. No None No No No 205 No No No ACCESSORIES DIN rail conversion kit for use on series 219 style sockets. 27390 (12 pin) and 33377 (14 pin) CX-4092 DIN Rail WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 194 OCTAL 8 or 11 PIN SCREW TERMINAL SOCKETS Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Non metallic spring mechanism eliminates mounting hardware. Pressure clamp screw terminals hold wires mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 12 AWG wires. One piece stamped metal interconnections. No welded or soldered connections. Fits all standard 8 and 11 pin relay plugs. Can also be surface mounted with 2 screws. DESIGNED FOR PANEL OR DIN MOUNT RATED: 10 AMPS, 300V MOLDED BASE, BREAK RESISTANT BLACK THERMOPLASTIC WITH CLOSED BACK. US C E70550 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. D IN R A IL 70-464-1 PANEL/DIN MOUNT SOCKET Struthers-Dunn Equivalent Part Number 75224 IN D WIRING DIAGRAMS R SPDT, DPDT IL A 3PDT 1 11 2 70-465-1 PANEL/DIN MOUNT SOCKET Struthers-Dunn Equivalent Part Number 75225 2 1 8 7 3 4 5 6 10 9 3 4 8 5 7 6 OUTLINE DIMENSIONS .165 Dia. Mounting Hole (2 Places) 2.33 Dimensions shown in Inches and (Millimeters) .165 Dia. Mounting Hole (2 Places) (59.1) 1.60 Max. (40.6) 2.05 (52.07) 2.020 (51.3) .125 - .156 (3.17 - 3.96) 2.06 (52.3) 6-32 x .312 Combination Head Screw & Pressure Clamp (11 Places) PART NUMBERS 70-464-1 70-465-1 Tolerances: ± .010 ± (0.25) Unless otherwise shown. STYLE 8 Pin Octal Socket, Panel/DIN mount, Screw Terminals 11 Pin Octal Socket, Panel/DIN mount,, Screw Terminals WEIGHT (GRAMS) .580 (14.73) .770 (19.56) .970 (24.6) P&B .125 - .156 (3.17 - 3.96) .150 (3.6) .150 (3.6) .610 (15.5) 1.29 (32.7) .830 6-32 x .312 Combination (21.08) Head Screw & Pressure Tolerances: ± .010 Clamp (11 Places) ± (0.25) Unless otherwise shown. IDEC CROSS REFERENCE CUSTOM CONNECTOR OMRON ALLEN-BRADLEY GRAINGER 23.8 27E891 27E122 SR2P-06 OT08-PC PF083A-E 700-HN125 5X852 75 27E892* 27E123 SR3P-06* OT11-PC PF113A-E* 700-HN126 6X156* Part Numbers shown also available thru Stocking Distribution Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary. * Track mountable but not compatible with Magnecraft mounting hole locations. PAGE 195 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS SCREW TERMINAL SOCKETS - 1, 2 & 4 POLE Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Non metallic spring mechanism eliminates mounting hardware. Pressure clamp screw terminals hold wires mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 14 AWG wires for the 70-461-1, and up to #12 AWG wires for the 70-459-1 sockets. One piece stamped metal interconnections. No welded or soldered connections. Can also be surface mounted with 2 screws. 78 DESIGNED FOR PANEL OR DIN MOUNT 4 POLE: RATED 7 AMPS @ 300 VOLTS 1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS US C E70550 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. D IN R L AI WIRING DIAGRAMS 7 6 5 4 3 4 3 2 1 2 1 8 7 6 5 .240 (6.10) Typ. 1.210 (30.7) L AI R OUTLINE DIMENSIONS IN 8 70-459-1 PANEL/DIN MOUNT SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 75227 13 14 Dimensions shown in Inches and (Millimeters) SPDT, DPDT D 4PDT 70-461-1 PANEL/DIN MOUNT SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 75228 12 11 10 9 1.015 (25.78) .315 (8.0) 1.18 (30) .156 (4.0) .160 (4.0) .170 (4.3) 2.550 (64.8) 2.65 (67.3) 1.275 (32.4) .197 ± .015 (5.0 ± 0.4) 1.325 (33.6) .785 (19.9) .895 (22.7) 1 or 2 4 1.00 (2.54) Tolerances: ± .010 ± (0.25) Unless otherwise shown. WEIGHT PART NO. OF SOCKET STYLE (GRAMS) NUMBERS POLES 70-459-1 70-461-1 1.080 (27.4) Screw Terminal Screw terminal 49.8 42.8 .800 (20.3) 1.02 (26) Tolerances: ± .010 ± (0.25) Unless otherwise shown. CROSS REFERENCE P&B 27E895 27E894 P&B IDEC 27E487* SH2B-05 27E166** SY4S-05 CUSTOM CONNECTOR GT08-15 MT14-PC OMRON PTF08A-E PYF14A-E ALLEN-BRADLEY GRAINGER 700-HN116 700-HN128 2A582 2A584 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary. * Panel mount ** Panel mount with grounding screw. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 196 CLASS CHASSIS MOUNT SOCKETS - 1, 2 & 4 POLE 78 Sockets fit Class 78 style relays. The sockets are chassis mounted and snap into panels up to .0625 (1.56) thick. The 4 pole socket has an additional receptacle and solder terminal for grounding 4 pole relays. SOLDER TERMINALS SNAPS INTO CHASSIS 4 POLE: RATED 5 AMPS @ 300 VOLTS 1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. US C E70550 70-378-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 32884 70-401-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 40051 OUTLINE DIMENSIONS Dimensions shown in Inches and (Millimeters) .850 (21.59) 1.015 (25.78) 1.150 (29.21) SNAP FITS INTO CHASSIS .0625 (1.56) THICK .075 (1.90) .623 (15.82) Ground lug .750 (19.05) .105 (2.67) .148 x .014 (3.75 x 0.355) 1 or 2 4 Solder Terminal Solder Terminal 6.5 6.2 1.158 ± .010 (29.41) 1.015 (25.8) .075 (1.90) .072 x .140 typ. (1.83 x 3.56) .440 (11.18) .770 (19.56) Tolerances: ± .010 ± (0.25) Unless otherwise shown. PART WEIGHT NO. OF SOCKET STYLE (GRAMS) NUMBERS POLES 70-401-1 70-378-1 .844 (21.44) .860 (21.8) R PA ECO NE M L C ME UT ND OU ED T R PA ECO NE M L C ME UT ND OU ED T .860 (21.84) .180 (4.57) Typ. CROSS REFERENCE P&B 27E488 27E006 IDEC SH2B-51 SY4S-51 CUSTOM CONNECTOR GR108-SLD MR14-SLD OMRON ALLEN-BRADLEY PT08 PY14 700-HN117 700-HN104 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, can vary. PAGE 197 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS CLASS PRINTEDP.C. CIRCUIT TERMINAL SOCKETS 2 & 4 POLE TERMINAL SOCKETS - 2 & 4- 1, POLE Sockets fit Class 78 style relays. The sockets are manufactured with "floating" (loose) P.C. terminals that allow the terminals to aline with holes in the circuit board without binding or bending to get correct fit and alignment of terminals. The 4 pole socket has an additional receptacle and solder terminal for grounding 4 pole relays. PRINTED CIRCUIT TERMINALS 4 POLE: RATED 5 AMPS @ 300 VOLTS 1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. US C 7878 E70550 70-402-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 41463 70-379-1 SOLDER TERMINAL SOCKET 16-1197 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number 39830 OUTLINE DIMENSIONS Dimensions shown in Inches and (Millimeters) RECOMMENDED PRINTED CIRCUIT LAYOUT Viewed from component side .350 (8.89) .160 (4.06) RECOMMENDED PRINTED CIRCUIT LAYOUT Viewed from component side .850 (21.5) .175 (4.45) .410 (10.4) .660 (16.7) .185 .145 (3.68) .262 (6.67) .070 Dia. (1.78) 14 Places .417 (10.5) .672 (17.07) 1.150 (29.21) .598 (15.19) .024 (0.61) .623 (15.82) Ground Lug .525 (13.34) .394 (10.0) .175 x .010 typ. (4.44 x .254) .440 (11.18) .086 Dia. (2.18) Tolerances: ± .010 ± (0.25) Unless otherwise shown. .060 Typ. (1.52) 1.158 ± .010 (29.41) .620 (15.7) .440 (11.18) .600 (15.24) .844 ± .010 (21.44) .672 (17.07) .078 Typ. (1.98) .140 x .014 (3.55 x 0.355) PART NO. OF SOCKET STYLE WEIGHT NUMBERS POLES (GRAMS) 70-402-1 70-379-1 1 or 2 4 Printed Circuit Printed Circuit 5.8 5.9 CROSS REFERENCE P&B IDEC 27E489 SH2B-62 27E031 SY4S-61 CUSTOM CONNECTOR OMRON ALLEN-BRADLEY GRAINGER GR108-PCB MR14-PCB PT08-0 PY14 700-HN118 700-HN105 2A583 - PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. Cross Reference reflects compatibility with relay foot prints. Shape, mounting and method of relay hold down can vary. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 198 CLASS 388 & 283 SCREW TERMINAL SOCKET - 1, 2 & 3 POLE Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Non metallic spring mechanism eliminates mounting hardware. Pressure clamp screw terminals hold wire mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 12 AWG wires. Break resistant thermoplastic. One piece stamped metal interconnections. No welded or soldered connections. Can also be surface mounted with 2 screws. FITS SQUARE BASE .187 (3/16") BLADE STYLE RELAYS RATED: 15 AMPS, 300 VAC US C E70550 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. D IN R A IL 70-463-1 PANEL/DIN SOCKET 16-1278 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Number-75226 OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). WIRING DIAGRAM TOP VIEW 4 6 5 6-32 X .312 Combination Head Screw and pressure clamp 1.03 (26.1) .390 (9.9) 1.70 (43.1) 1.435 (36.4) 3 9 1 A B 3.00 (76.2) 1.57 (39.9) .150 Dia. (3.8) (2 Places 2 8 7 .150 Retaining notch for (3.81) hold down clip (2 Places) Tolerances: ± .010 ± (0.25) Unless otherwise shown. PART NUMBERS 70-463-1 * STYLE 11 Pin, Panel/DIN rail mount, with Screw Terminals WEIGHT (GRAMS) 50.6 P&B IDEC 27E893 SR3B-05 CROSS REFERENCE CUSTOM CONNECTOR ALLEN-BRADLEY GRAINGER ST11-PC 700-HN127 5X853 Part Numbers shown also available thru Stocking Distribution * Order Part Number 16-1278 Hold Down Clip for relays with a case height of 1.90" using 3/16" (.187) terminals Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary. PAGE 199 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS SOLDER, Q.C. OR P.C. TERMINALS - 1, 2 & 3 POLE FITS SQUARE BASE .187 (3/16") BLADE STYLE RELAYS RATED: 15 AMPS, 300 VAC Sockets fit Class square base style relays with 3/16" (.187) terminals. The quick connect, solder terminal and printed circuit sockets have mounting tabs for mounting to panels using two screws. The 70-178-2 Printed circuit socket has no mounting tabs Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. US C 388 & 283 E70550 RECOMMENDED CHASSIS CUTOUT BOTTOM VIEW BOTTOM VIEW 1.39 (35.4) .391 (9.94) 16-722-2 Spring Clip Ordered separately. Struthers-Dunn Equivalent Part Numbers 36580 = 70-124-1 36581 = 70-124-2 36579 = 70-178-1 1.68 1.27 (42.7) (32.3) OUTLINE DIMENSIONS .257 (6.53) DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). FIG. "A" .875 (22.2) .437 (11.1) .829 (21.0) 1.68 (42.7) .611 (15.5) .287 (7.54) Drill 11 .078 (1.98) dia.holes for P.C. terminals .875 (22.2) .205 (5.21) Drill two .156 (3.96) dia. holes for mounting Tabs. .156 (3.96Dia. (2 holes) .125 (3.17) .500 typ (12.7) RECOMMENDED PRINTED CIRCUIT BOARD LAYOUT Note: Holes not required when using Fig. "B" style socket FIG. "B" P.C. MOUNT 2.03 (51.6) 1.687 (42.85) 1.50 (38.1) 1.25 (31.75) 1.37 (34.8) .218 (5.54) .875 (22.2) 1.37 (34.8) .165 Dia.(4.19) 2 holes .540 (13.72) Connectors are Brass, Tin Plated. .297 (7.5) .130 Solder Terminal or .187 (3/16" Q.C. Terminal 1.50 (38.1) .156 (3.96) .297 (7.5) .156 (3.96) Printed Circuit mounting Tolerances: ± .010 ± (0.25) Unless otherwise shown. Printed Circuit mounting with mounting Tabs PART NUMBERS 70-124-1 70-124-2 70-178-1 70-178-2 FIG FIG "A" FIG "A" FIG "A" FIG "B" STYLE .130 SOLDER TERMINAL 3/16" (.187) QUICK CONNECT PRINTED CIRCUIT, WITH TABS PRINTED CIRCUIT, NO TABS WEIGHT (GRAMS) 12.1 12.1 9.4 9.4 CROSS REFERENCE CUSTOM CONNECTOR ALLEN-BRADLEY GRAINGER 27E043 SR3B-51 CM11-SLD 5X854 27E067 700-HN107 CM11-QDC 27E304 CM11-PCB CM11-PCB-1S P&B IDEC Part Numbers shown also available thru Stocking Distribution Order Part Number 16-722-2 Hold Down Clip (Struthers-Dunn Equivalent 37067) for relays with a case height of 1.90 (48.2) Cross Reference reflects compatibility with relay foot prints. Shape, mounting and method of relay hold down can vary. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 200 SERIES SCREW TERMINAL SOCKETS 219 12 and 14 PIN PANEL MOUNT SOCKETS FIT ALL 219 STYLE RELAYS WITH 12 OR 14 PIN PLUGS. RATED: 10 AMPS, 600 VAC These Industrial style sockets offer front-connected wiring on one level with screw terminals accessible and numbered for ease in installation, wiring and checkout. Sockets are polarized. The mating relay has a locking clip that snaps into the socket, eliminating any need for external holding devices. All sockets are supplied with an insulating paper back plate for greater dielectric strength. US C E13224 E70550 Recognized to Canadian safety requirements under the Component Recognition Program of Underwriters Laboratories Inc. UL LISTED WHEN USED WITH SERIES 219 RELAYS 27390 - 12 PIN PANEL MOUNT SOCKET 33377 - 14 PIN PANEL MOUNT SOCKET OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). 12 PIN SOCKET 2.65 (67.3) 1.687 (42.84) 3.10 (78.74) .484 (12.29) 1.687 (42.84) .484 (12.29) 2.18 (55.3) .687 (17.4) 2.18 (55.3) .687 (17.4) 6-32 screws 12 Places 14 PIN SOCKET Tolerances: ± .010 ± (0.25) Unless otherwise shown. 6-32 screws 14 Places .173 (4.39) mounting Holes 2 Places .173 (4.39) mounting Holes 2 Places .780 (19.8) .780 (19.8) INSULATING PAPER BACK PLATE INSULATING PAPER BACK PLATE Struthers-Dunn PART NUMBERS 27390 33377 STYLE 12 PIN SOCKET 14 PIN SOCKET WEIGHT CROSS REFERENCE (GRAMS) CUSTOM CONNECTOR SD12-PC 102 SD14-PC 120 Part Number Shown also Available thru Stocking distribution Notes: Insulating Back Plate Included with Socket When Sockets are mounted end to end, the distance between adjacent mounting holes should be 1" minimum. PAGE 201 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 CLASS SCREW TERMINAL SOCKETS - 1 & 2 POLE Compatible with European 35 mm DIN rail mounting. Time saving snap in installation. Pressure clamp screw terminals hold wires mechanically secure. Pressure clamp terminals provide excellent electrical connection. Terminals accept up to two # 14 AWG wires. One piece stamped metal interconnections. No welded or soldered connections. Fits all standard Class 76 relays Can also be surface mounted with 1 screw. 76 PANEL/DIN RAIL MOUNT. DIELECTRIC STRENGTH 1500 V rms, 1 MINUTE. RATED: 15 AMPS, 250 VAC. OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). 70-475-1 PANEL/DIN SOCKET 16-1321 Spring Clip Ordered separately. SOCKET PART NO. (SPDT) 70-478-1 .615 (15.6) .150 Dia. (3.81) SOCKET PART NO. (DPDT) 70-475-1 .615 (15.6) .153 (3.89) 1.25 (31.7) .150 Dia. (3.81) 1.02 (26) .75 (19) 2.765 (70.23) Tolerances: ± .010 ± (0.25) Unless otherwise shown. PART NUMBERS STYLE STANDARD FOOT PRINT FOR STYLE 76EURCPCXSPDT, Panel/DIN mount, Screw Terminal 70-478-1 DPDT, Panel/DIN mount, Screw terminal 70-475-1 WEIGHT CROSS REFERENCE (GRAMS) P&B IDEC 19.3 19.5 27E1038 27E1039 RP 78 604 RP 78 605 Part Numbers Shown also Available thru Stocking distribution Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary. WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 202 CLASS 67 SOLDER TERMINAL SOCKETS - 2 TO 8 POLE CHASSIS MOUNT SOCKETS RATED: 10 AMPS MAX. Sockets fit Class 67 style relays with solder/plug-in terminals. All sockets have an grounding strip that connects with the mounting screw to the chassis. Contact material used is spring brass, tin plated. The body material is phenolic. Dielectric strength: 1000 V rms. Insulation Resistance 10 9 megohms .210 (5.33) 70-303-1 OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: ± .010 ± (0.25) Unless otherwise shown. .210 (5.33) .350 (8.89) 2 POLE .978 (24.8) 70-307-1 16-875-1 Spring hold down Clip included .350 (8.89) 6 POLE 1.390 (35.3) 16-875-3 Spring hold down Clip included .210 (5.33) 70-305-1 4 POLE 1.184 (30.1) .210 (5.33) 70-309-1 8 POLE 16-875-2 Spring hold down Clip included .350 (8.89) 1.596 (40.54) 16-1120-8 Spring hold down Clip included CHASSIS CUTOUT for panel mounting. .281 (7.14) CHASSIS CUTOUT DIMENSION "B" "B" .281 ± .015 (7.14) ± 0.38 .656 ± .015 (16.66) ± 0.38 .354 (8.99) .140 (3.5) CHASSIS MOUNT SPDT DPDT 4PDT 6PDT 8PDT .343 .562 .781 1.00 (8.71) (14.3) (19.84) (25.4) .109 DIA. (2.77) .090 X .045 (2.3 X 1.14) Elongated Holes .210 (5.33) .750 (19.05) .350 (8.89) USE 3-48 SCREW & NUT FOR MOUNTING SOCKET GROUND STRIP FOR 3-48 UN-2A STUD PART NUMBERS 70-303-1 70-305-1 70-307-1 70-309-1 NO. OF POLES SOCKET STYLE 2 4 6 8 Solder Terminal Solder Terminal Solder Terminal Solder Terminal WEIGHT CROSS REFERENCE (GRAMS) POTTER-BRUMFIELD 4.3 5.5 6.9 8.5 27E125 27E126 27E127 27E211 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. RELAY HOLD DOWN CLIP IS INCLUDED WITH ALL SOCKETS PAGE 203 WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 .350 (8.89) CLASS P.C. TERMINAL SOCKETS - 2 TO 8 POLE Sockets fit Class 67 style relays with solder/plug-in terminals. All sockets have an grounding strip that connects with the mounting screw to the chassis. Contact material used is spring brass, tin plated. The body material is phenolic. Dielectric strength: 1000 V rms. Insulation Resistance 10 9 megohms 67 PRINTED CIRCUIT SOCKETS RATED: 10 AMPS MAX. OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). .180 (457) 70-304-1 Tolerances: ± .010 ± (0.25) Unless otherwise shown. .350 (8.89) 2 POLE .978 (24.8) 16-875-1 Spring hold down Clip included .180 (457) 70-306-1 4 POLE .350 (8.89) 1.184 . (30.1) 16-875-2 Spring hold down Clip included .180 (4.57) 70-308-1 6 POLE .350 (18.9) 1.390 (35.3) 16-875-3 Spring hold down Clip included .180 (457) 70-310-1 8 POLE .350 (8.89) 1.596 (40.54) 16-1120-8 Spring hold down Clip included SUGGESTED P.C. BOARD LAYOUT TOP VIEW (Component side of board) .500 (12.70) .750 (19.05) 8 Pole .100 (2.54) GRID typical 6 Pole 4 Pole 2 Pole .500 (12.7) .056 + .004 Dia. - .000 Holes (1.42 + .10) - .00 USE 3-48 SCREW & NUT FOR MOUNTING SOCKET .450 (11.43) .150 (3.81) GROUND STRIP FOR 3-48 UN-2A STUD NOTE: WHEN INSTALLING SOCKET(S) INTO A PRINTED CIRCUIT BOARD, USE PLUG-IN STYLE RELAYS FOR MAXIMUM TERMINAL CONTACT WITH MATING SOCKETS. PLUG-IN STYLE RELAYS HAVE A GROUNDING STUD AND ARE RECOMMENDED FOR USE WITH ALL SOCKET STYLES. .100 (2.54) PART NUMBERS NO. OF POLES 70-304-1 70-306-1 70-308-1 70-310-1 2 4 6 8 SOCKET STYLE WEIGHT (GRAMS) P.C. Terminal P.C. Terminal P.C. Terminal P.C. Terminal 4.3 5.5 6.9 8.5 CROSS REFERENCE POTTER-BRUMFIELD 27E128 27E129 27E130 27E254 PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION. RELAY HOLD DOWN CLIP IS INCLUDED WITH ALL SOCKETS WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 204 CLASS SOLDER TERMINAL SOCKET 97 CHASSIS MOUNT SOCKET ACCEPTS .250 CONTACT TERMINALS AND .110 COIL TERMINALS. Recommended RATED: 25 AMPS Chassis Layout OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: ± .010 ± (0.25) Unless otherwise shown. 3 2.126 + .004 1.65 (41.9) .175 ± .005 (4.44) ± .127) 2 Holes 5 4 6 1.57 (39.8) 1 2 7 9 10 8 2.12 (53.8) 1.65 (41.9) 2.50 (63.5) 70-312 .988 (25.09) 1.57 (39.8) .098 Dia. (2.48) (2 Places) .118 Dia. (2.99) (8 Places) Part Number STYLE WEIGHT (GRAMS) 70-312 10 Contact socket, Chassis Mounted, Solder Terminal 48 Part Number Shown also Available thru Stocking distribution CLASS P.C. TERMINAL, DUAL INLINE SOCKET DIP DIP (DUAL INLINE PACKAGE) PHOSPHOR BRONZE CONTACTS, TIN PLATED THERMOPLASTIC POLYESTER BODY 0.100 GRID SPACING OUTLINE DIMENSIONS DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS). Tolerances: ± .010 ± (0.25) Unless otherwise shown. 70-276 Equal Spacing at .100 Centers Suggested Layout .396 (10.06) Part Number STYLE 70-276 14 Pin DIP Socket, 0.100 Pin Spacingl WEIGHT (GRAMS) 1 Part Number Shown also Available thru Stocking distribution PAGE 205 .696 (17.7) .200 (5.08) .035 Dia, (.889) 0.100 Grid Pattern .015 (.38) .130 (3.30) .025 x .008 Terminals (.63 x .20) WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 S E C T I O N 11 11 UTILIZATION CATEGORIES Page 206 UTILIZATION CATEGORIES FOR LOW VOLTAGE SWITCHGEAR AND CONTROL GEAR Nature of Category Current AC AC-1 AC-2 AC-3 AC-4 AC-5a AC-5b AC-6a AC-6b AC-7a AC-7b AC-8a AC-8b 947-4 947-5 Control of A.C. electromagnetic loads. Connecting and disconnecting under no-load conditions, Switching of resistive loads, including moderate overloads. Switching of mixed resistive and inductive loads, including moderate overloads. Switching of motor loads or other highly inductive loads. 947-3 A B Protection of circuits, with no rated short time withstand current Protection of circuits, with a rated short time withstand current 947-2 DC-1 DC-3 Non-inductive or slightly inductive Loads, resistance furnaces Shunt-motors, Starting, plugging 1), inching 2), dynamic breaking of motors. Series-motors, Starting, plugging 1), inching 2), dynamic breaking of motors. Switching of incandescent lamps. Control of resistive loads and solid state loads with isolation by optocouplers. Control of DC electromagnets Control of DC electromagnetic loads having economy resistors in circuit. Connecting and disconnecting under no-load conditions Switching of resistive loads, including moderate overloads. Switching of mixed resistive and inductive loads, including moderate overloads (e.g. shunt motors) Switching of highly inductive loads (e.g. series motors). AC-13 AC-14 AC-15 AC-20 AC-21 AC-22 AC-23 DC Non-inductive or slightly inductive Loads, resistance furnaces Slip-ring motors: Starting, switching off. Squirrel-cage motors: Starting, switching off motors during running. Squirrel-cage motors: Starting, plugging 1), inching 2) Switching of electric discharge lamp control Switching of incandescent lamps. Switching of transformers Switching of capacitor banks. Slightly inductive loads in household appliances and similar applications. Motor-loads for household applications. Hermetic refrigerant compressor motor control with manual resetting of overload releases. Hermetic refrigerant compressor motor control with automatic resetting of overload releases. Relevant I.E.C. Product Standard Control of resistive loads and solid state loads with isolation by optocouplers. Control of solid state loads with transformer isolation. Control of small electromagnetic loads. AC-12 AC and DC Typical Applications DC-5 DC-6 DC-12 DC-13 DC-14 DC-20 DC-21 DC-22 DC-23 947-4 947-5 947-3 1) By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections while the motor is running. 2) By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small movements of the drive mechanism PAGE 207 WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100 CUSTOMER SERVICE STAFF & SUPPORT Tel: 843/393-5778 Fax: 843/393-4123 Pricing Delivery Cross-Reference Return Authorization Order Entry Bill Moody Shelby Hall Natalie Campbell Beverly Streett Gaye Register Tel: 843/393-5421 Product Quality Application Engineering Assistance Jim Berg Fax: 843/393-4123 Q.C. Manager Les Wynne MIL Spec. Bill Brady Solid State & Time Delay Relays Tom Mahaffey Industrial Relays Tel: 847/441-2531 Gene Piskorz Chuck Johnson Tel: 843/393-5421 Invoices Customer Service Manager Sr. Customer Service Coord. Customer Service Coordinator Customer Service Coordinator Customer Service Coordinator Marjorie Bacote Fax: 847/4412522 Industrial Relays P.C. Relays Fax: 843/393-7843 Credit Manager Magnecraft/Struthers-Dunn is an innovator and provider of quality relay products with a hands on commitment to staying close to customers worldwide. Our Goal is to deliver defect-free products on time, all the time. We Pledge ourselves to achieve these goals in a manner which assures profitability and resources to support growth. We Encourage an atmosphere where diligence and hard work can exist in harmony with warmth, laughter, continuing education and personal development. We will conduct business in a way that encourages integrity in every employee, supplier and customer relationship. Magnecraft Struthers-Dunn LIMITED WARRANTY MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. warrants its product to be free of defects in workmanship and materials for a period of one year from date of delivery to the purchaser buying direct from MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. or authorized Distributor. This warranty includes, but is not limited to those products manufactured to specifications supplied to us by the purchaser. Any defects appearing more than one year from the date of delivery to the purchaser, shall be deemed to be due to ordinary wear and tear. MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. assumes no risk or liability for the suitability or unsuitability or results of the use of its products, used in combinations with any electrical or electronic components, circuits, systems, assemblies, or any other material or substances, or environments. The purchaser's right under this warranty shall consist solely of requiring MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to repair, or in MAGNECRAFT'S/ MSD's sole discretion, replace, free of charge, F.O.B., factory, any defective items received at its factory within said year, as determined by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to be defective. All products to be returned to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. for evaluation under this warranty, shall first receive a Return Authorization Number and Shipping Label from our Sales Department. All products shall be shipped to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. prepaid. All products received at MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. without written authorization and return label, shall be returned at the sender's expense. The failure to give or the giving of any advice or recommendations by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. shall not constitute any warranty by, or impose any liability upon MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. The sole and exclusive remedy of the purchaser and the exclusive liability of MAGNECRAFT ELECTRIC COMPANY/MSD, Inc. are outlined and stated above, AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS, OR ANY OTHER MATTER. In no event shall MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. be liable for consequential or special damages, or for the delay in the performance of this warranty. MAGNECRAFT & STRUTHERS DUNN 700 ORANGE STREET DARLINGTON, SC. 29532-3739 TEL.: (843) 393-5778 FAX: (843) 393-4123 WEBSITE: www.magnecraft.com EMAIL: [email protected] EUROPE MAGNECRAFT & STRUTHERS-DUNN OFFICE MUNICH FORSTENRIEDER ALLEE 227 .. D 81476 MUNCHEN / GERMANY TEL.: 4989 75080310 FAX: 4989 7558344 PRINTED IN U.S.A. 981015K Magnecraft Struthers-Dunn LIMITED WARRANTY MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. warrants its product to be free of defects in workmanship and materials for a period of one year from date of delivery to the purchaser buying direct from MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. or authorized Distributor. This warranty includes, but is not limited to those products manufactured to specifications supplied to us by the purchaser. Any defects appearing more than one year from the date of delivery to the purchaser, shall be deemed to be due to ordinary wear and tear. MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. assumes no risk or liability for the suitability or unsuitability or results of the use of its products, used in combinations with any electrical or electronic components, circuits, systems, assemblies, or any other material or substances, or environments. The purchaser's right under this warranty shall consist solely of requiring MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to repair, or in MAGNECRAFT'S/ MSD's sole discretion, replace, free of charge, F.O.B., factory, any defective items received at its factory within said year, as determined by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to be defective. All products to be returned to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. for evaluation under this warranty, shall first receive a Return Authorization Number and Shipping Label from our Sales Department. All products shall be shipped to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. prepaid. All products received at MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. without written authorization and return label, shall be returned at the sender's expense. The failure to give or the giving of any advice or recommendations by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. shall not constitute any warranty by, or impose any liability upon MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. The sole and exclusive remedy of the purchaser and the exclusive liability of MAGNECRAFT ELECTRIC COMPANY/MSD, Inc. are outlined and stated above, AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY AS TO MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS, OR ANY OTHER MATTER. In no event shall MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. be liable for consequential or special damages, or for the delay in the performance of this warranty. U.S.A. MAGNECRAFT & STRUTHERS DUNN 700 ORANGE STREET DARLINGTON, SC. 29532-3739 TEL.: (843) 393-5778 FAX: (843) 393-4123 WEBSITE: www.magnecraft.com EMAIL: [email protected] EUROPE MAGNECRAFT & STRUTHERS-DUNN OFFICE MUNICH FORSTENRIEDER ALLEE 227 .. D 81476 MUNCHEN / GERMANY TEL.: 4989 75080310 FAX: 4989 7559344 PRINTED IN U.S.A. 981015K