ETC W172DIP-147

Magnecraft
Struthers-Dunn
PRODUCT INDEX
DESCRIPTION
CLASS TO CLASS CROSS REFERENCE GUIDE
STOCKING DISTRIBUTORS, SALES REPRESENTATIVES & AGENTS
SECTION 1
PAGE 1 & 2,
DOCUMENT 100
PAGE
DOCUMENT #
INSIDE FRONT COVER
3
340
341
4-7
115
SELECTOR GUIDE
Socket Compatible and General Purpose Relays - 1 to 30 Amperes
W78
W67
A314/W250
284
W388/283
W388/283
W389
W389
W97
219
RSX-1800
W21
W88HP
1, 3, 5, 10 & 15 Amp, P.C. and Solder/Plug-in
3, 5 Amp, P.C. and Solder/Plug-in
10 Amp, Octal Plug-in
10 Amp, Solder Plug-in
General Specifications
11 to 15 Amp, Solder Plug-in and Flange mount
General Specifications & Ratings
30 Amps, Flange Mount
25 Amp, Plug-in and Side Stud mounting
10 Amp, Pin Base Plug-in
5 Amps, Pin Base Plug-in
30 Amps, Plug-in with Polarizing Pin.
10 AMP, Octal Plug-in, Hermetically Sealed
8 - 12
13 - 15
16 - 18
19, 20
21, 22
23 - 25
26 - 28
29, 30
31, 32
33, 34
35, 36
37
38
116
117
118
120
119
119
121
121
122
123
124
125
126
SECTION 2
SELECTOR GUIDE
39 - 43
342
Printed Circuit Board Relays - 1 to 30 Amperes
276
W90
W91
W9A
W92
W7
W60
W178
W49
W76
W1330 & W1335
7 & 10 Amp, Subminiature
30 Amp Miniature
30 Amp, P.C. and Flange mount
30 Amp, P.C.and Flange mount
30 Amp, P.C.and Flange mount
2 Amp, Subminiature
2 AMP, Miniature
5 & 10 AMP, Miniature
3, 5 & 10 AMP, P.C.and Flange Mount
10 & 16 AMP, Miniature
5 Amp, Miniature
44
45, 46
47, 48
49, 50
51, 52
53, 54
55, 56
57, 58
59, 60
61, 62
63
109
102
103
104
105
106
107
112
113
114
108
SECTION 3
SELECTOR GUIDE
64 - 67
127
Application Data
SIP, 0.5 Amp, 4 pin, SPST-NO or NC
DIP, 0.5 Amp, 8 pin, SPST-NO
Specifications
DIP, 0.5 Amp, 8 pin, 1 & 2 pole-NO or NC
DIP, 0.5 Amp, Dual Coil Latch, SPST-N.O.
DIP. 0.5 - 1.0 Amp, SPDT, DPDT
General Specifications
Miniature, 0.5 Amp, 1 to 3 pole NO & Latching
Miniature, 2 Amp, 1 & 2 pole NO Mercury
Miniature, 0.25 Amp,SPDT, DPDT
Miniature, 1.0 Amp, SPDT, DPDT Mercury
Miniature, 0.5 Amp, up to 6 pole NO or 4PDT.
Miniature, 0.5 Amp, with End Terminals
Axial Lead, Shielded, 0.5 Amp,
Open Style Metal Cover/Shield,
Open Style Metal Cover/Shield
Coxial R.F. switching
68, 69
70
71
72
73
74
74, 75
76
77
78
79
80
81, 82
83, 84
85, 86
87, 88
89
90
343
128
129
130
130
131
131
132
133
133
134
134
135
136
137
139
138
344
SELECTOR GUIDE
91 - 93
140
94 - 95
96
97, 98
99, 100
101
102, 103
104 - 107
108
108
345
141
142
143
144
145
146
147
147
Reed Relays for P.C. Board Applications - 3 VA to 100 VA
REED
W117
W107,
W171, W172
W171
MRRDL
W172
W101, W104, W131,W134,W193
W101,
W131
W104
W134
W193
MR-Y
MRR & RR
RRN
W102
W120
SECTION 4
Solid State Relays - 2 to 75 Amperes
Solid State Relays
W226, W230, W231
W226
W230
W231
W6
W6
W301T
W6
PAGE 1
Application Data
General Specifications
Miniature ,7 Amp, P.C. or Push-on Terminals
Miniature, 1.5 or 3 Amp. P.C Terminals
Miniature, 4 Amp, Spade Terminals, Flange mount
General Specifications
2.5 to 75 Amp. Screw Terminals
Opto Isolator, axial Lead
Embossed Safety Cover
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SECTION 5
DESCRIPTION
PAGE
DOCUMENT #
SELECTOR GUIDE
109 - 112
148
Application Data
Octal Style, 10 Amp
Octal Style ,Programmable, 10 Amp,
Miniature, 5 Amp
Repeat Cycle, 10 Amps,
Square base, 12Amp,Solder/plug-in or Flange
1 - 3 pole, 10 Amps, Solder/Plug-in, flange panel screw.
Octal 1 -3 Pole, 10 Amp,
Industrial Plug-in with Locking Clip. 10 Amps,
Industrial Plug-in with Locking Clip. 10 Amps,
Current Sensor, 10 Amps, Plug-in or Screw panel mount
Voltage Sensor, 10 Amps, up to 400 HZ 1-3 Phase
Voltage Sensor, 10-13 Amps, Solder/Plug-in or Octal
113, 114
115, 116
117
118
119
120 - 124
125, 126
127, 128
129 - 130
131
132
133
134, 135
149
151
150
152
153
154
346
347
348
157
158
159
160
SELECTOR GUIDE
136 - 139
161
140 - 146
147
148
149, 150
151, 152
153, 154
155, 156
157
158, 159
160 - 164
165
162
163
170
171
166
167
168
169
164
165
349
Time Delay Relays and Sensors
Time Delay Relays
W211
W211PROG
W67
W222
W388
286/287
326, 327
236, 237 & 238
246, 247
W235
349
W236
SECTION 6
Relays and Contactors - 15 to 200 Amperes
W199
425
W88UKD
415
275
575
101, 102, 103
214
MDR
MDR
102, 103
Open Style, 30 Amp , SPDT
Open Style, 30 Amp Power Relay up to 3 pole
Miniature Open Style, 30 Amp, SPST-NO DM
Open Style, 15 Amp, 1 & 2 Pole.
Motor Reversing Contactor, 15 Amp, 3 Pole
Motor Reversing Contactor, 30 Amp, 6 Pole
Solenoid Style Contactor, SPST-DM, 50 to 200 Amps
Ground Fault Interrupt (GFI), 20 Amp, DPDT
General Specifications & Application Data
Mercury Displacement relays 30 to 100 Amp
Solinoid Style Lighting Contactor 100 & 200 Amps
SECTION 7
SELECTOR GUIDE
166 - 168
172
Latching, Sequence and Stepper Relays
Sequence & Latching
W250ML
W388ML/285
308
B255
W88L
311
C85
Application Data
Octal Base, Magnetic Latching, 10 Amps
Latching, 10 Amp, Solder/Plug-in
Latching, 10 Amp, 4 Pole. Solder/Plug-in
Mechanical Latch, 10 Amps, Pin base Plug-in
Open or Enclosed Mechanical Latch,10 Amp
Plug-in Sequence (Stepper), 5 Amp
Open Style, Sequence (Stepper) 20 Amp
169
170
171, 172
173, 174
175, 176
177, 178
179
180
350
177
173
174
175
176
179
180
SECTION 8
SELECTOR GUIDE
181, 182
181
183
184
182
183
SELECTOR GUIDE
185, 186
184
112, 112PGF
67S
392
292
Low Power, 2 Amps, Pin Base Plug-in w/ locking clip
Miniature Sensitive, 3 Amps, 2 - 6 Poles.
Sensitive, Octal Plug-in, 5 Amps, 1 - 3 Poles
Solder/plug-in, 5 Amps, 1 - 3 Poles
187, 188
189
190
191
185
351
186
187
SECTION 10
SELECTOR GUIDE
192 - 194
188
195
196
197, 198
199
200
201
202
203, 204
205
205
189
191
191
192
193
197
196
190
195
195
Hi- Voltage Relays - 2,500 to 10,000 Volts
158
102HV
Open Style, 200 mA, 5000Vdc
Encapsulated Reed, 10-30mA, up to 10kv
SECTION 9
Sensitive Relays, Low Input Power
Sockets and Accessories
70--464-1, 70-465-1
70-459-1, 70-461-1
70-378-1, 70-401-1, 70-379-1, 70-402-1,
70-463-1
70-124-1 & -2, 70-178-1 & -2
27390, 33377
70-475, 70-478
70-303-1 THRU 70-310-1
70-312
70-276
SECTION 11
CE
Customer Service Staff
Series A314/250, 8 & 11 Pin Octal, Panel/DIN mount
CLASS 78 Panel/DIN mount
Class 78, Chassis, P.C.,
Class 388/283 Style, Panel/DIN Mount
Class 388/283 Style, Chassis Mount or P.C.
Series 219 style, Panel mount, screw terminal
Class 76 Style, Panel/DIN mount
Class 67 chassis mount
Class 97 Style, Chassis mount
DIP Style, 14 Pin
UTILIZATION CATAGORIES
Utilization Categories
Staff Directory
206
207
INSIDE BACK COVER
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
199
198
PAGE 2
Magnecraft
Struthers-Dunn
FAX ON DEMAND DIRECTORY
✭ STOCKING DISTRIBUTORS.
✭ FACTORY DIRECT FIELD SALES PROFESSIONALS.
✭ U.S. AND INTERNATIONAL AGENTS.
PLEASE DIAL 800-891-2957
FOR AN UP-TO-DATE DIRECTORY FOR YOUR AREA.
WHEN PROMPTED, PLEASE ENTER THE APPROPRIATE
DOCUMENT NUMBER FROM THE MAP BELOW.
DOCUMENT NUMBER OUTSIDE THE U.S. & CANADA:
CANADA DOCUMENT NUMBER:
352
353
370
359
354
360
369
356
365
361
355
368
364
367
357
358
362
363
366
UNITED STATES DOCUMENT NUMBERS SHOWN INSIDE THE STATES.
PAGE 3
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N
1
1
SOCKET COMPATIBLE
AND
FLANGE MOUNTED
GENERAL PURPOSE RELAYS
2 TO 30 AMPERES
Page 4
Magnecraft
Struthers-Dunn
SOCKET COMPATIBLE
RELAY SERIES
A314/250
67
78
SEE SECTION 10
FOR MATING SOCKETS
QUALIFIED
POLYCARBONATE DUST COVER
FEATURES
ISO 9002
QS 9000
ISO 9002
QS 9000
POLYCARBONATE DUST COVER. POLYCARBONATE DUST COVER
SOLDER/PLUG-IN OR PC BOARD
MOUNTING.
SOLDER/PLUG-IN OR PC BOARD 8 OR 11 PIN OCTAL PLUG-IN
MOUNTING
INDUSTRY STANDARD FOOTINDUSTRY STANDARD FOOTPRINTS.
INDUSTRY STANDARD FOOTPRINTS
UP TO 4 POLES WITH STANDARD OR PRINTS.
INDICATOR LAMP AND PUSH
BIFURCATED CONTACTS, INDICATOR
UP TO 8 POLES WITH STANDARD BUTTON AVAILABLE.
LAMP AND PUSH BUTTON,
OR BIFURCATED CONTACTS.
TOP FLANGE COVER , PANEL/DIN,
PANEL/DIN STYLE SOCKETS
CHASSIS OR P.C STYLE SOCKETS
CHASSIS OR PC STYLE
AVAILABLE.
AVAILABLE.
SOCKETS AVAILABLE.
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
SPDT, DPDT
15 &10
AMPS
AT
120/240 VAC
4PDT
1, 3 & 5
AMPS
AT
120/240 VAC
SPDT TO 8PDT
STANDARD CONTACTS
5 AMP
BIFURCATED CONTACTS
3 AMP
AT 120VAC/32VDC
SILVER, GOLD PLATED - 1A
SILVER, GOLD OVERLAY
SILVER, GOLD FLASHED - 3A
SILVER CADMIUM OXIDE - 5, 10 & 15A
50 MILLIOHMS (INITIAL)
50 & 100 MILLIOHMS MAX
SPDT
DPDT
3PDT
12
12
10
AMPS
AMPS
AMPS
AT
AT
AT
120 VAC 120 VAC 240 VAC
SILVER CADMIUM OXIDE,
( GOLD FLASHED)
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC
1500 V rms
STRENGTH
1500 V rms
1500 V rms
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (VAC)
WATTS,: (VDC)
6, 12, 24,120 & 240 VAC
6, 12, 24, 48 & 110 VDC
120 VAC
5, 12, 24, 48 &115 VDC
24, 120 & 240 VAC
12, & 24 VDC
1.2 VA
0.9 WATTS
2.5 VA
2 WATTS
2.75 VA
1.2 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
TIMING VALUES
MAX. OPERATE:
MAX. RELEASE:
LIFE
MECHANICAL:
ELECTRICAL:
- 40˚ C to + 70˚ C
25 MILLISECONDS
25 MILLISECONDS
AC- 50M, - DC-100M OPER'S.
200,000 OPERATIONS .
H
DIMENSIONS
W
L
.858 X 1.10 X 1.40
APPROVALS
PAGE NUMBER
PAGE 5
C
- 55˚ C to + 70˚ C
- 55˚C to + 105˚C
- 10˚ C to + 50˚ C (AC)
- 10˚ C to + 60˚ C (DC)
- 30˚ C to + 105˚ C
18 MILLISECONDS
8 MILLISECONDS
25 MILLISECONDS
20 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
10 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
1.20 X .735 X -
C
US
PAGE 8 THRU 12
H
W
L
1.37 X 1.37 X 2.25
PAGE 13 THRU 15
US
PAGE 16 THRU 18
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
SOCKET COMPATIBLE & FLANGE MOUNT
POLYCARBONATE
389
388 & 283
284
DUST
COVER.
POLYCARBONATE
97
QUALIFIED
QUALIFIED
ISO 9002
QS 9000
ISO 9002
QS 9000
DUST
COVER.
POLYCARBONATE
FLANGED DUST COVER.
3/16" SOLDER/PLUG-IN, OR PC
BOARD MOUNTING
3/16" SOLDER/PLUG-IN, FLANGE OR PC
BOARD MOUNTING
INDUSTRY STANDARD FOOTPRINT.
INDUSTRY STANDARD FOOTPRINTS.
1/4" Q.C./SOLDER LUG
TERMINALS FOR QUICK
CONNECT.
CAPABLE OF SWITCHING UP TO 30
AMPS.
WIDE SELECTION OFPANEL/DIN,
CHASSIS & P.C. STYLE SOCKETS
INDUSTRY STANDARD
FOOTPRINTS
WIDE CHOICE OF OPTIONS.
15 AMP VERSIONS & TOP FLANGE
COVERS AVAILABLE.
TOP FLANGE COVER
AVAILABLE.
4PDT
SPDT
MAX TOTAL LOAD 30
AMPS @ 120 VAC,
20 AMPS @ 240 VAC
10 AMPS PER POLE
NOT TO EXCEED 30
AMPS
13 AMPS
AT
240 VAC
SILVER CADMIUM OXIDE,
SILVER OR GOLD DIFFUSED
50 MILLIOHMS (INITIAL)
3PDT
DPDT
12 AMPS
AT
240 VAC
11 AMPS
AT
240 VAC
388B STYLES RATED UP
TO 10 AMPS AT 150 VDC.
SILVER CADMIUM OXIDE,
( GOLD FLASHED)
50 MILLIOHMS (INITIAL)
SPDT-NO-NC
(DM-DB)
SPDT,
DPDT
25 AMPS @ 30 AMPS @
300 VAC
300 VAC
3PDT
20 AMPS @
150 VAC
SILVER CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
METAL DUST COVER
1/4" BRASS CONTACT
TERMINALS
DPDT-NO-NC
(DM-DB) CONTACTS
CHOICE OF MOUNTING
MATING SOCKETS
DPDT NO-NC (DM-DB)
25 AMPS @
120 VAC/28VDC
TUNG. LAMP 25A,
120VAC
SILVER ALLOY
50 MILLIOHMS, (INITIAL)
2000 V rms
2200 V rms
6, 12, 24, 48, 120 & 240 VAC
6, 12, 24, 48, 115-125 VDC
24, 120 & 240 VAC
12, 24 & 120 VDC
24, 120 & 240 VAC
12, & 24 VDC
24, 120 & 240 VAC
12, 24 & 120 VDC
3.4 VA
1.9 WATTS
2.75 VA
1.2 WATTS
3.5 VA
1.44 WATTS
8 VA
3 WATTS
- 30˚ C to + 50˚ C (AC)
- 30˚ C to + 65˚ C (DC)
- 30˚ C to + 100˚ C
- 30˚ C to + 50˚ C (AC)
- 30˚ C to + 65˚ C (DC)
- 30˚ C to + 100˚ C
1500 V rms
- 45˚ C to + 45˚ C (AC, COVR..)
- 45˚ C to + 70˚ C (DC, COVR)
- 45˚ C to + 85˚ C (DC, OPEN)
15 MILLISECONDS
10 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
1.50 X 1.93 X 1.87
24 MILLISECONDS
30 MILLISECONDS
5 MILLION OPERATIONS
100,000 OPERATIONS
H
L
1.40 X 1.53 X 1.90
C
PAGE 19, 20
W
US
PAGE 21 THRU 25
20 MILLISECONDS
20 MILLISECONDS
5 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
1.40 X 1.53 X 1.90
C
2000 V rms
- 20˚ C to + 50˚ C
35 MILLISECONDS
35 MILLISECONDS
5 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
1.56 X 1.56 X 2.06
US
PAGE 26 THRU 30
PAGE 31, 32
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 6
Magnecraft
Struthers-Dunn
SOCKET COMPATIBLE
RELAY SERIES
219
RSX-1800
POLYCARBONATE DUST
COVER
POLYCARBONATE DUST
COVER
21
88HP
SEE SECTION 10
FOR MATING SOCKETS
FEATURES
12 OR 14 PIN STYLES
ENCAPSULATED COIL
WIDE CHOICE OF CONTACT
COMBINATIONS.
LARGE CHOICE OF
OPTIONS
MATING SOCKETS
AVAILABLE
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
VARIOUS COMBINATIONS
10 AMPS @
240 VAC/28 VDC
12 PIN STYLES PERFORMS
BASIC FUNCTIONS OF AN
ALARM POINT
OPERATES FROM AN N.O.
OR N.C. TROUBLE CONTACT
POLYCARBONATE DUST
COVER
HERMETICALLY SEALED
STEEL ENCLOSURE
MEETS NEMA STD. TS 21992
APPROVED BY D.O.T
10 AMP AND 12 AMP
CONTACTS
INDUSTRY STANDARD
FOOTPRINT
8 OR 11 PIN OCTAL
BASE.
MATING SOCKETS AVAILABLE
2 PAIR of DPDT or 3PDT
10 AMPS @
120VAC, 28 VDC
20 AMPS @
120/240 VAC, 28 VDC
20 AMPS, 120VAC
TUNGSTEN
(2 POLE)
12 AMPS @ 120VAC
8 AMPS @ 240 VAC
(3 POLE)
10 AMPS @ 120VAC
6 AMPS @ 240 VAC
SILVER CADMIUM OXIDE
SILVER ALLOY
SILVER CADMIUM OXIDE
Available with Make
Before Break contacts
CONTACT
MATERIAL:
CONTACT
RESISTANCE:
SILVER CADMIUM OXIDE,
GOLD DIFFUSED
50 MILLIOHMS (INITIAL)
DPDT, 3PDT
DPDT
50 MILLIOHMS (INITIAL)
100 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
1500 V rms
1500 V rms
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH
1500 V rms
1500 V rms
COIL DATA
6, 12, 24, 120 & 240 AC
6,12, 24(28),32,115(125)DC
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (VAC)
WATTS,: (VDC)
5 VA
1.8 WATTS
6, 12, 24 & 120 VAC
6, 12, 24 & 110-125 VDC
120 VAC
OPTIONAL VDC
120 VAC
12, 24 VDC
5 VA
1.8 WATTS
4 & 8 VA
-
3.0 VA
1.5 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
TIMING VALUES
MAX. OPERATE:
MAX. RELEASE:
LIFE
MECHANICAL:
ELECTRICAL:
- 10˚ C to + 60˚ C
- 10˚ C to + 70˚ C
- 40˚ C to + 84˚ C
- 10˚C to + 50˚C (AC),
- 10˚C to + 60˚C (DC),
-30˚C to + 105˚C
25 MILLISECONDS
20 MILLISECONDS
25 MILLISECONDS
20 MILLISECONDS
25 MILLISECONDS
25 MILLISECONDS
25 MILLISECONDS
20 MILLISECONDS
20 MILLION OPERATIONS
100,000 OPERATIONS
20 MILLION OPERATIONS
500,000 OPERATIONS
5 MILLION OPERATIONS
250,000 OPERATIONS
5 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
.2.62 X 1.468 X 2.593
H
W
L
.2.47 X 1.85 X 2.84
H
W
L
.2.62 X 1.468 X .2.593
DIMENSIONS
APPROVALS
C
PAGE NUMBER
PAGE 7
PAGE 33, 34
PAGE 35, 36
H
W
L
1.53 X 1.53X 2.03
US
PAGE 37
PAGE 38
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
W78ACSX & CSX
4PDT, SOLDER/PLUG-IN
1, 3 OR 5 AMP
W78APCX & PCX
4PDT, PRINTED CIRCUIT
1, 3 OR 5 AMP
MANUFACTURED UNDER QUALITY SYSTEM
ISO 9002 & QS 9000
W78ARCSX & RCSX
SPDT, DPDT, SOLDER/PLUG-IN
10 OR 15 AMP
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E52197
SPECIFICATIONS CLASS 78
CONTACTS
Contact Configurations:
Contact Material:
Contact Resistance:
Contact Rating:
75% of Nominal Voltage or less for DC, 80% of nominal or less for AC.
DC -10% min., AC - 30% min.
110%
±15% AC & DC
Class "B" coil insulation system (130˚C per UL standard 1446)
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
SPDT, DPDT, 4PDT.
1 Amp Bifurcated Silver Gold plated. 3 AMP Silver Gold flashed
5 Amp, Silver Cadmium Oxide. 10 & 15 AMP, Silver Cadmium Oxide.
100 Milliohms Max.(3, 5, 10 & 15AMP) @ 6V, 1 AMP
50 Milliohms Max. ( 1 AMP) @ 6V, 0.1 AMP
4PDT- Bifurcated 1Amp @ 120/240 VAC 30VDC. 1/16HP (2.8A FLA), 120VAC.
Pilot duty - 5A make, 1/2A break, 1 A continuous, 120 VAC
4PDT- 3 Amps @ 120/240 VAC, 30VDC, 1/10HP 120/240VAC, C300 pilot duty.
4PDT- 5 Amps @ 120/240 VAC, 30VDC, 1/6 HP 120/240VAC, C300 pilot duty
DPDT -10 Amps @ 120/240VAC, 30VDC.1/3 HP,120VAC. 1/2HP 240VAC.
SPDT -15 Amps @ 120/240VAC, 30VDC.1/3 HP 120VAC, 1/2 HP 240VAC.
25mS Max. @ Nominal Voltage.
25 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Coil to Frame:
Across Open Contacts:
Contact to Frame:
Insulation Resistance:
1500 V rms
1000 V rms
1500 V rms
100 Megohms Min. @ 500 VDC.
TEMPERATURE
Ambient Temperature:
-40˚C to + 70˚C @ Rated Operation
MISCELLANEOUS
Enclosure:
Weight:
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
2.3 Watts DC, 2.55 VA (60Hz) AC, approx. 5 minutes max. @ 40˚C
Continuous
TIMING
Operate Time:
Release Time:
VIBRATION RESISTANCE
Functional:
,
SHOCK RESISTANCE
Mechanical Durability:
Malfunction Durability:
LIFE EXPECTANCY
Mechanical (No Load):
Electrical (rated Load):
78
W78ARPCX & RPCX
SPDT, DPDT, SOLDER/PLUG-IN
10 OR 15 AMP
*
COIL
Pull-in Voltage:
Dropout:
Max. Voltage:
Coil Resistance:
Coil Insulation:
Maximum tolerable coil
dissipation:
Duty:
CLASS
NEW
EPOXY SEALED VERSIONS
AVAILABLE. CONSULT FACTORY.
10 to 55 Hz; 1mm ( Double Amplitude).
Mechanical Durability, 1000 m/s2 (approx.100 G ).
Malfunction Durability, 200 m/s2 (approx. 20 G ).
10,000,000 Operations (AC & DC).
200,000 Operations Min. (at rated Resistive load).
Clear Polycarbonate Dust Cover, Molded.
SPDT & DPDT 1.41 oz, (Approx. 40 g) , 4PDT 2.47 oz. (Approx. 70 g).
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 8
CLASS
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
78
OUTLINE DIMENSIONS
Dimensions shown in INCHES and (MILLIMETERS)
WIRING DIAGRAM
FOR 4PDT RELAY
Optional FLANGED COVER available on special order as Non-Stock.
.138Typ.
(.3.51)
.020 Typ.
(.51)
1
2
3
4
5
6
7
8
10 11
12
9
1.33
(33.8)
14
13
1.10 Max.
(27.9)
1.72 Max.
(43.7)
Observe polarity
when L.E.D. Indicator
is installed across
coil. ( DC Styles Typ.)
(+)
14
(-)
13
OR
DC STYLES
AC STYLES
ALL INDICATOR LAMP STYLE RELAYS
HAVE AN ADDITIONAL LAMP CIRCUIT
INSTALLED ACROSS COIL.
.079
(2.0)
1.40 Max. P.C. Style
(35.56)
.020
(.51)
.140
(3.56)
.51
(12.95)
.858 Max.
(21.8)
P.C.
STYLE
Q.C.
STYLE
1.40 Max.
(35.56) 1.65 Max.
(41.91)
.250 max
(6.35)
.51
(12.95)
.100
(2.54)
.17
(4.32)
.17 (4.32)
.16 (4.06)
.040 Max.
(1.02)
.50 (12.7)
.25
(6.35)
ALL 4 POLE RELAYS HAVE
OPPOSITE POLARITY ARC
BARRIERS AS A STANDARD
FEATURE. ARC BARRIERS
PROVIDE GREATER VOLTAGE PROTECTION BETWEEN
ADJACENT POLES
.25
(6.35)
.15
(3.81)
ARC
BARRIE
R
.05 dia. (1.27)
14 holes
P.C MOUNTING HOLE LAYOUT
( BOTTOM VIEW )
NEW!
1 AMP
4PDT
CONTACTS
BIFURCATED
1 AMP
Coil measured @ 25˚C
Nominal
Nominal
Nominal
Power
Resistance
Input
(Approx.)
(Ohms)
Voltage
RELAYS
CROSS REFERENCE TO
POTTER & BRUMFIELD
IDEC
OMRON
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78ATCSX-2
W78ATCSX-3
W78ATCSX-5
W78ATCSX-6
12 VAC
24VAC
120 VAC
240 VAC
46
180
4430
15,700
1.2VA
1.2VA
1.2VA
1.2VA
KHAU17A96-12
KHAU17A96-24
KHAU17A96-120
KHAU17A96-240
RY42S-U-AC12V
RY42S-U-AC24V
RY42S-U-AC110/120V
RY42S-U-AC220/240V
MY4Z-UA-AC12
MY4Z-UA-AC24
MY4Z-UA-AC120
MY4Z-UA-AC240
KHAU17A96N-120
RY42S-UL-AC24V
RY42S-UL-AC110/120V
RY42S-UL-AC220/240V
MY4ZN-UA-AC12
MY4ZN-UA-AC24
MY4ZN-UA-AC240
KHAU17D96-6
KHAU17D96-12
KHAU17D96-24
KHAU17D96-110
RY42S-U-DC6V
RY42S-U-DC12V
RY42S-U-DC24V
RY42S-U-DC100/110V
MY4Z-UA-DC6
MY4Z-UA-DC12
MY4Z-UA-DC24
MY4Z-UA-DC110
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP.
W78ANTCSX-4
W78ANTCSX-5
W78ANTCSX-7
24 VAC
120VAC
240 VAC
180
4430
15,700
1.2VA
1.2VA
1.2VA
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
W78TCSX-1
W78TCSX-2
W78TCSX-3
W78TCSX-5
6 VDC
12 VDC
24VDC
110 VDC
40
160
650
11,000
0.9W
0.9W
0.9W
1.1W
DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP
24 VDC
0.9W
KHAU17D96L-24
650
RY42S-UL-DC24V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION.
W78NTCSX-5
MY4ZN-UA-DC24
SEE SECTION 10 FOR MATING SOCKETS
PAGE 9
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
4PDT
CONTACTS
3 AMP
78
RELAYS - 3 AMP
Coil measured @ 25˚C
Nominal
Nominal
Nominal
Power
Resistance
Input
(Approx.)
(Ohms)
Voltage
CROSS REFERENCE TO
POTTER & BRUMFIELD
OMRON
IDEC
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78ACSX-2
W78ACSX-3
W78ACSX-5
W78ACSX-6
12 VAC
24VAC
120 VAC
240 VAC
46
180
4430
15,700
1.2VA
1.2VA
1.2VA
1.2VA
RY4S-U-AC12V
RY4S-U-AC24V
RY4S-U-AC110/120V
RY4S-U-AC220/240V
MY4-UA-AC12
MY4-UA-AC24
MY4-UA-AC120
MY4-UA-AC240
KHAU17A91N-120
KHAU17A91N-240
RY4S-UL-AC24V
RY4S-UL-AC110/120V
RY4S-UL-AC220/240V
MY4N-UA-AC12
MY4N-UA-AC24
MY4N-UA-AC240
KHAU17D91-6
KHAU17D91-12
KHAU17D91-24
KHAU17D91-110
RY4S-U-DC6V
RY4S-U-DC12V
RY4S-U-DC24V
RY4S-U-DC100/110V
MY4-UA-DC6
MY4-UA-DC12
MY4-UA-DC24
MY4-UA-DC110
KHAU17D91N-24
RY4S-UL-DC24V
MY4N-UA-DC24
KHAE17A11-24
KHAE17A11-120
RY4V-U-AC24V
RY4V-U-AC110/120V
MY4-02-UA-AC24
MY4-02-UA-AC120
KHAE17D11-12
KHAE17D11-24
KHAE17D11-110
RY4V-U-DC12V
RY4V-U-DC24V
RY4V-U-DC100/110V
MY4-02-UA-DC12
MY4-02-UA-DC24
MY4-02-UA-DC110
KHAU17A91-12
KHAU17A91-24
KHAU17A91-120
KHAU17A91-240
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP.
W78ANCSX-24
W78ANCSX-25
W78ANCSX-26
24 VAC
120VAC
240 VAC
180
4430
15,700
1.2VA
1.2VA
1.2VA
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
6 VDC
12 VDC
24VDC
110 VDC
W78CSX-1
W78CSX-2
W78CSX-3
W78CSX-6
40
160
650
11,000
0.9W
0.9W
0.9W
1.1W
DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP
W78NCSX-23
24 VDC
650
0.9W
AC OPERATED - PRINTED CIRCUIT STYLE
W78APCX-3
W78APCX-5
24 VAC
12 0 VAC
180
4430
1.2VA
1.2VA
DC OPERATED - PRINTED CIRCUIT STYLE
W78PCX-2
W78PCX-3
W78PCX-6
12 VDC
24 VDC
110 VDC
160
650
11,000
0.9W
0.9W
1.1W
4PDT
CONTACTS
5 AMP
RELAYS - 5 AMP
Coil measured @ 25˚C
Nominal
Nominal
Nominal
Power
Resistance
Input
(Approx.)
(Ohms)
Voltage
CROSS REFERENCE TO
POTTER & BRUMFIELD
IDEC
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78KACSX-15
W78KACSX-17
W78KACSX-18
12 VAC
24VAC
120 VAC
240 VAC
46
180
4430
15,700
1.2VA
1.2VA
1.2VA
1.2VA
KHAU17A21-12
KHAU17A21-24
KHAU17A21-120
KHAU17A21-240
RY4S-U-AC12V
RY4S-U-AC24V
RY4S-U-AC110/120V
RY4S-U-AC220/240V
KHAU17D21-12
KHAU17D21-24
RY4S-U-DC12V
RY4S-U-DC24V
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
W78KCSX-12
W78KCSX-13
12 VDC
24VDC
160
650
0.9W
0.9W
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION.
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 10
CLASS
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
78
OUTLINE DIMENSIONS
Dimensions shown in INCHES and (MILLIMETERS)
DOUBLE POLE DOUBLE THROW
Optional FLANGED COVER available on special order as Non-Stock.
.138Typ.
(.3.51)
.020 Typ.
(.31)
1.375 Max.
(34.92)
5
6
(+)
8
(-)
7
8
DC STYLES
ALL INDICATOR LAMP STYLE RELAYS
HAVE AN ADDITIONAL LAMP CIRCUIT
INSTALLED ACROSS COIL.
.187 Typ.
(4.75)
.858 Max.
(21.8)
.560
(14.2)
.39 (9.91)
.16 (4.06)
P.C.
STYLE
Q.C.
STYLE
4
AC STYLES
1.72 Max.
(43.7)
.080 Typ.
(2.03)
.040
(1.02)
1.375 Max. P.C. Style
(34.92)
.18
(4.57)
.12 Dia.
(3.04 )
Typ.
3
OR
1.10 Max.
(27.9)
.079
(2.0)
2
7
1.33
(33.8)
Observe polarity
when L.E.D. Indicator
is installed across
coil. ( DC Styles Typ.)
1
.18 (4.57)
.52 (13.21)
.28
(7.11)
.291 Max.
(7.39)
.13 (3.30)
0.10 dia.(2.54)
8 holes
P.C MOUNTING HOLE LAYOUT
( BOTTOM VIEW )
DPDT
RELAYS - 10 AMPS
DPDT, 10 AMP
STANDARD
COVER
Coil measured @ 25˚C
Nominal
Nominal
TOP FLANGE Input Nominal
Resistance Power
COVER
(Approx.)
Voltage (Ohms)
CROSS REFERENCE TO*
POTTER &
BRUMFIELD
IDEC
OMRON
K10P11A15-6
K10P11A15-24
K10P11A15-120
K10P11A15-240
RH2B-U-AC6V
RH2B-U-AC24V
RH2B-U-AC110/120V
RH2B-U-AC220/240V
LY2-UA-AC6
LY2-UA-AC24
LY2-UA-AC120
LY2-UA-AC240
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78ARCSX-7
W78ARCSX-9
W78ARCSX-11
W78ARCSX-12
78ARCSX-1
78ARCSX-3
78ARCSX-5
78ARCSX-6
6 VAC
24VAC
120 VAC
240 VAC
12.2
180
4430
15,700
1. VA
1.2VA
1.2VA
1.2VA
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP.
W78ARNCSX-6
W78ARNCSX-5
W78ARNCSX-7
24 VAC
120VAC
240 VAC
180
4430
15,700
1.2VA
1.2VA
1.2VA
RH2B-UL-AC24V
LY2N-UA-AC24
K10L11A15-120 RH2B-UL-AC110/120V LY2N-UA-AC120
RH2B-UL-AC220/240V LY2N-UA-AC240
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
W78RCSX-6
W78RCSX-7
W78RCSX-8
W78RCSX-9
W78RCSX-10
78RCSX-1
78RCSX-2
78RCSX-3
78RCSX-4
78RCSX-5
6 VDC
12 VDC
24VDC
48 VDC
110 VDC
0.9W
0.9W
0.9W
0.9W
1.1W
40
160
650
2,600
11,000
K10P11D15-6
K10P11D15-12
K10P11D15-24
K10P11D15-48
K10P11D15-110
RH2B-U-DC6V
RH2B-U-DC12V
RH2B-U-DC24V
RH2B-U-DC48V
RH2B-UL-DC100/110V
LY2-UA-DC6
LY2-UA-DC12
LY2-UA-DC24
LY2-UA-DC48
LY2-UA-DC110
RH2B-UL-DC24V
LY2N-UA-DC24
DC OPERATED COIL -SOLDER/PLUG-IN WITH INDICATOR LAMP
W78RNCSX-6
24 VDC
0.9W
650
AC OPERATED COIL -P.C. TERMINAL STYLE
W78ARPCX-5
W78ARPCX-6
120 VAC
240 VAC
4430
15,700
1.2VA
1.2VA
K10P11A55-120 RH2V2-U-AC110/120V
K10P11A55-240 RH2V2-U-AC220/240V
LY2-0-UA-AC120
LY2-0-UA-AC240
DC OPERATED COIL -P.C. TERMINAL STYLE
W78RPCX-1
W78RPCX-2
W78RPCX-3
6VDC
12 VDC
24 VDC
40
160
650
0.9W
0.9W
0.9W
K10P11D55-6
K10P11D55-12
K10P11D55-24
RH2V2-U-DC6V
RH2V2-U-DC12V
RH2V2-U-DC24V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION.
LY2-0-UA-DC6
LY2-0-UA-DC12
LY2-0-UA-DC24
* Applies to Standard Cover
SEE SECTION 10 FOR MATING SOCKETS
PAGE 11
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
ICE CUBE STYLE SOLDER/PLUG-IN OR PC BOARD RELAY
78
OUTLINE DIMENSIONS
Dimensions shown in INCHES and (MILLIMETERS)
SINGLE POLE DOUBLE THROW
Optional FLANGED COVER available on special order as Non-Stock.
1
2
3
4
5
7
6
Observe polarity
when L.E.D. Indicator
is installed across
coil. (DC Styles Typ.)
.138Typ.
(.3.51)
.020 Typ.
(.31)
1.33
(33.8)
(+)
8
(-)
7
8
OR
DC STYLES
AC STYLES
1.10 Max.
(27.9)
1.72 Max.
(43.7)
ALL INDICATOR LAMP STYLE RELAYS
HAVE AN ADDITIONAL LAMP CIRCUIT
INSTALLED ACROSS COIL.
.187 Typ.
(4.75)
.080 Typ.
(2.03)
.040
(1.02)
1.375 Max. P.C. Style
(34.92)
.18
(4.57)
.12 Dia.
(3.04 )
Typ.
.079
(2.0)
.39 (9.91)
.16 (4.06)
P.C.
STYLE
Q.C.
STYLE
1.375 Max.
(34.92)
.560
(14.2)
.858 Max.
(21.8)
.18 (4.57)
.52 (13.21)
.28
(7.11)
.291 Max.
(7.39)
.13 (3.30)
0.10 dia.(2.54)
8 holes
P.C MOUNTING HOLE LAYOUT
( BOTTOM VIEW )
SPDT RELAYS - 15 AMPS
Coil measured @ 25˚C
SPDT, 15 AMP
STANDARD
COVER
TOP FLANGE
COVER
Nominal
Input
Voltage
Nominal
Resistance
(Ohms)
CROSS REFERENCE TO *
Nominal
Power
(Approx.)
OMRON
AC OPERATED COIL - SOLDER/PLUG-IN STYLE.
W78ARCSX-108
W78ARCSX-109
W78ARCSX-111
W78ARCSX-112
78ARCSX-33
78ARCSX-34
78ARCSX-36
78ARCSX-37
12 VAC
24VAC
120 VAC
240 VAC
46
180
4430
15,700
1.2VA
1.2VA
1.2VA
1.2VA
LY1-UA-AC12
LY1-UA-AC24
LY1-UA-AC120
LY1-UA-AC240
AC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP
24 VAC
120VAC
240 VAC
W78ARNCSX-8
W78ARNCSX-9
W78ARNCSX-10
180
4430
15,700
1.2VA
1.2VA
1.2VA
LY1N-UA-AC24
LY1N-UA-AC120
LY1N-UA-AC240
DC OPERATED COIL - SOLDER/PLUG-IN STYLE
W78RCSX-96
W78RCSX-97
W78RCSX-98
W78RCSX-100
78RCSX-31
78RCSX-32
78RCSX-33
78RCSX-35
6 VDC
12 VDC
24VDC
110 VDC
40
160
650
11,000
0.9W
0.9W
0.9W
1.1W
LY1-UA-DC6
LY1-UA-DC12
LY1-UA-DC24
LY1-UA-DC110
DC OPERATED COIL - SOLDER/PLUG-IN WITH INDICATOR LAMP
W78RNCSX-10
24 VDC
650
0.9W
LY1N-UA-DC24
AC OPERATED COIL -P.C. TERMINAL STYLE
W78ARPCX-81
W78ARPCX-82
W78ARPCX-84
12 VAC
24 VAC
120 VAC
46
180
4430
1.2VA
1.2VA
1.2VA
LY1-0-UA-AC12
LY1-0-UA-AC24
LY1-0-UA-AC120
DC OPERATED COIL -P.C. TERMINAL STYLE
W78RPCX-79
W78RPCX-83
W78RPCX-85
12 VDC
24 VDC
110 VDC
160
650
11,000
0.9W
0.9W
1.1W
LY1-0-UA-DC12
LY1-0-UA-DC24
LY1-0-UA-DC110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIUBUTION.
* Applies to Standard Cover
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 12
CLASS
MINIATURE ENCLOSED INDUSTRIAL RELAY
67
CONTACT MATERIAL: SILVER GOLD OVERLAY
RATED 3 or 5 AMPS @ 32VDC/120VAC
WIRING DIAGRAM
The Class 67 Relays have combination
solder/plug-in terminals with a 3-48UNC
stud or printed circuit terminals.
8PDT
6PDT
UL RECOGNIZED
FILE NO. E52197
4PDT
DPDT
Standard Class 67 miniature industrial relays are designed
for applications requiringDPDT to 8PDT contacts where
space and weight are of prime importance.
Shatter resistant, see-thru plastic covers are utilized to
protect against dust, tampering and electrical shock.
The 67T models have Bifurcated Contacts and
are designed for low level switching applications.
SEE SECTION 10 FOR MATING SOCKETS.
4
TYPICAL CONTACT LIFE EXPECTANCY FOR SWITCHING
RESISTIVE LOADS @ 25˚C
Load
Current
5.0A
5.0A
2.0A
1.0A
0.5A
0.1A
0.1A
50mA
30mA
1mA
10A
Load
Voltage
28 VDC
120VAC
28VDC/120VAC
28VDC/120VAC
28VDC/120VAC
28VDC/120VAC
6 VDC
6 VDC
6 VDC
6 VDC
10mVDC
Number of
Operations
Standard
adjustment
5 X 104
5 X 104
1.5 X 106
1.2 X 107
5 X 107
5 X 107
5 X 107
1
2
3
Bottom View
CLASS 67 TYPICAL TIMING VALUES
POLES
DPDT
4PDT
6PDT
8PDT
OPERATE TIME
012
.014
.016
.018
RELEASE TIME .008
.008
.008
.008
Measured at Nominal Voltage @ 25˚C
SPECIFICATIONS CLASS 67
COIL
Pickup voltage:
Dropout voltage:
Coil resistance:
Maximum coil dissipation:
Coil Temperature rise:
Maximum coil temperature:
CONTACTS
Contact material:
Contact resistance:
CAPACITANCE
Between contacts:
Contact to coil:
Coil to frame:
PAGE 13
80% of nominal voltage or less.
10% of nominal or more.
± 10% measured @ 25˚C
2.2 watts
30˚C per watt
105˚C
Silver, Gold overlay
50 milliohms max. initial
2 pf, typ.
2 pf, typ.
30 pf, typ.
DIELECTRIC STRENGTH
Contact to coil:
Across open contacts:
Coil to frame:
Contacts to frame:
Insulation resistance:
1500 V rms
500 V rms
1000 V rms
1500 V rms
1000 megohms @ 25˚C & 50% R.H.
TEMPERATURE
Operating:
Storage:
-55˚C to + 70˚C
-55˚C to +105˚C
MISCELLANEOUS
Solder-bath temperature: +525˚F (260˚C) 10 seconds max.
Enclosure Material:
Polycarbonate see thru plastic cover.
Operating Position:
Any
Weight:
0.77 to 1.4 oz. (22 to 40 grams)
OPTIONS:
Other options such as other coil voltages, sensitivities, contact arrangements
and epoxy sealing are available on special order. Consult Factory for special
requirements.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
MINIATURE ENCLOSED INDUSTRIAL RELAY
67
OUTLINE DIMENSIONS
Dimensions shown in INCHES and (MILLIMETERS)
DIMENSIONS
Tolerances ± .010 Inches
"A"
CONTACT
CONFIGURATION
"A"
DPDT
.978
(24.8)
4PDT
1.156
(29.4)
6PDT
1.374
(34.9)
8PDT
1.592
(40.4))
1.20 Max.
(30.3)
.094
(2.3)
.170
(4.3)
.200 Max.
(5.1)
3-48UNC-2A Thd.
DIM.
Elongated Hole .100 x .040 ( 2 x .1)
All Contact Terminals are .010 Thick
all coil terminals are .018 Thick.
"A"
P.C RELAY PIN LAYOUT
SUGGESTED PRINTED CIRCUIT BOARD LAYOUT
FOR RELAYS WITH PRINTED CIRCUIT TERMINALS
1.20 Max.
(30.3)
.400
(10.2)
.200
(5.1)
.053
(1.35)
.630 .740
(18.8)
.530 (16.0)
(13. 4)
.210
(5.3)
.110
(2.7)
.060 ±.002 Dia.
(1.5) ± (.05)
.320
(8.1)
COIL
TERMINALS
.032
(0.80)
.735 Max.
(18.7)
.135
(3.42)
.420
(10.6)
.550
(13..97)
.098
(2.48)
Typ.
.225
(5.7)
.450
(11.43)
.165
(4.19) Typ.
.040
(1.0)
Typ.
CONTACT
TERMINALS
All Contact Terminals are .010 Thick.
All Coil Terminals are .018 Thick.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 14
CLASS
MINIATURE ENCLOSED INDUSTRIAL RELAY
67
DC OPERATED - SOLDER TERMINAL or PLUG-IN STYLE
COIL
STANDARD CONTACTS
PART NUMBERS
W67RCSX-1
W67RCSX-2
W67RCSX-3
W67RCSX-4
W67RCSX-5
W67RCSX-6
W67RCSX-7
W67RCSX-8
W67RCSX-9
W67RCSX-10
W67RCSX-12
W67RCSX-13
W67RCSX-17
W67RCSX-18
Measured @ 25˚C
CONTACT
RATING
NOMINAL
INPUT
VOLTAGE
NOMINAL
RESISTANCE
(OHMS)
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5
12
24
48
115
5
12
24
48
115
12
24
12
24
52
185
700
2500
15,000
52
185
700
2500
15,000
90
430
72
350
NOMINAL
POWER
(WATTS)
CONTACT
CONFIGURATION
1/2W
3/4W
1W
1W
1W
1/2W
3/4W
1W
1W
1W
1.5W
1.5W
2W
2W
CROSS REFERENCE
TO
POTTER & BRUMFIELD
DPDT
DPDT
DPDT
DPDT
DPDT
4PDT
4PDT
4PDT
4PDT
4PDT
6PDT
6PDT
8PDT
8PDT
R10E1(X or Y)2-V28
R10E1(X or Y)2-V185
R10E1(X or Y)2-V700
R10E1(X or Y)2-V2.5K
R10E1(X or Y2-V15.0K
R10E1(X or Y)4-V28
R10E1(X or Y)4-V185
R10E1(X or Y)4-V700
R10E1(X or Y)4-V2.5K
R10E1(X or Y)4-V15.0K
R10E1(X or Y)6-V185
R10E1(X or Y)6-V700
R10E1(X or Y)8-V185
R10E1(X or Y)8-V700
DPDT
DPDT
4PDT
4PDT
6PDT
6PDT
8PDT
8PDT
R10E1(P or Z)2-V185
R10E1(P or Z)2-V700
R10E1(P or Z)4-V185
R10E1(P or Z)4-V700
R10E1(P or Z)6V185
R10E1(P or Z)6-V700
R10E1(P or Z)8-V185
R10E1(P or Z)8-V700
DC OPERATED - BIFURCATED CONTACTS - FOR LOW LEVEL SWITCHING APPLICATIONS
W67TRCSX-2
W67TRCSX-3
W67TRCSX-7
W67TRCSX-8
W67TRCSX-12
W67TRCSX-13
W67TRCSX-17
W67TRCSX-18
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
185
700
185
700
90
430
72
350
12
24
12
24
12
24
12
24
3/4W
1W
3/4W
1W
1.5W
1.5W
2W
2W
DC OPERATED - PRINTED CIRCUIT STYLE
STANDARD CONTACTS
PART NUMBERS
W67RPCX-2
W67RPCX-3
W67RPCX-7
W67RPCX-8
W67RPCX-12
W67RPCX-13
CONTACT
RATING
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
5 AMPS
COIL
NOMINAL
INPUT
VOLTAGE
12 VDC
24 VDC
12 VDC
24 VDC
12 VDC
24 VDC
Measured @ 25˚C
NOMINAL
NOMINAL
POWER
RESISTANCE
(WATTS)
(OHMS)
185
1W
700
1W
185
1W
700
1W
90
1.5W
430
1.5W
CONTACT
CONFIGURATION
DPDT
DPDT
4PDT
4PDT
6PDT
6PDT
CLASS 67 - AC OPERATED RELAYS - SOLDER TERMINAL or PLUG-IN STYLE 50/60 Hz
STANDARD CONTACTS
COIL Measured @ 25˚C
CONTACT
NOMINAL
NOMINAL
NOMINAL
CONFIGUCONTACT
PART NUMBERS
POWER
INPUT
RESISTANCE
RATION
RATING
(WATTS)
VOLTAGE
(OHMS)
W67ARCSX-5
120 VAC
1.5VA
5 AMPS
DPDT
W67ARCSX-10
120 VAC
5 AMPS
2.5VA
4PDT
W67ARCSX-15
120 VAC
2.5VA
5 AMPS
6PDT
CROSS REFERENCE
TO
POTTER & BRUMFIELD
R10E2(X or Y)2-V185
R10E2(X or Y)2-V700
R10E2(X or Y)4-V185
R10E2(X or Y)4-V700
R10E2(X or Y)6-V185
R10E2(X or Y)6-V700
CROSS REFERENCE
TO
POTTER & BRUMFIELD
R10E1(X or Y)2-120V
R10E1(X or Y)4-120V
R10E1(X or Y)6-120V
Part numbers shown also available thru Stocking Distribution.
STANDARD CONTACTS
BIFURCATED CONTACTS
( LOW LEVEL APPLICATIONS)
(5 AMP CROSS BAR)
SEE SECTION 10 FOR MATING SOCKETS
PAGE 15
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
CLASS
A314 & 250
FEATURES
Plug-in, 8 or 11 pin "Octal Style Base" with see thru plastic dust cover.
Standard SPDT, DPDT or 3PDT contact arrangements. Other contact
arrangements available on special order.
Dielectric Strength to 1500 Vrms.
8 or 11 pin octal style plug-in are standard and Interchangeable with
other general purpose relays of this type.
Available with combinations of Indicator lamps, push to test button and
Blow-out Magnets for DC switching applications.
MANUFACTURED UNDER QUALITY SYSTEM
ISO 9002 & QS 9000
Recognized Component mark for
Canada and the United States.
C
US
WIRING DIAGRAM
UL Recognized
File No. E43641
(-)
VIEWED FROM PIN END
3PDT
(-)
(+)
DPDT
(+)
SPDT
ALL INDICATOR LAMP STYLE RELAY HAVE AN ADDITIONAL LAMP CIRCUIT
INSTALLED ACROSS COIL. OBSERVE COIL POLARITY WHEN L.E.D. INDICATOR IS INSTALLED ACROSS COIL (DC STYLES TYP.).
OUTLINE DIMENSIONS
Dimensions are shown in Inch and (Millimeter).
Artwork marking side
2.81 max.
(71.4)
1.37
(34.79)
2.25 max.
(57.2)
4
5
3
6
1.37
(34.79)
7
2
1
8
CONTACT RATINGS TABLE
POLES
120 VAC
240 VAC
SPDT
12 AMP
1/3 HP
12 AMP
1/2 HP
10 AMP
12 AMP
1/3 HP
10 AMP
1/2 HP
10 AMP
10 AMP
1/3 HP
10 AMP
1/2 HP
10 AMP
DPDT
3PDT
28 VDC
SEE SECTION 10
FOR
MATING SOCKETS
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 16
CLASS
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
A314 & 250
CLASS A314 & 250
8 OR 11 PIN OCTAL PLUG-IN WITH SEE THRU DUST COVER.
Enclosure is a clear high impact plastic (polycarbonate)
dust cover that is screwed to the base to protect against dust,
damage and tampering.
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E43641
SPECIFICATIONS SERIES A314 & 250 RELAYS
COIL
Pull-in voltage:
80% of nominal voltage or less. for DC coils
85% of nominal voltage or less for AC coils.
10% of nominal voltage or more.
± 10 % measured @ 25 ˚C
125 milliwatts per pole
1.2 Watts for DC coils, 2 VA-2.75VA for AC coils
Capability of DC coils 3.0 Watts max.
Continuous
Drop-out:
Coil resistance:
Minimum sensitivity:
Nominal power:
Maximum coil dissipation:
Duty:
CONTACTS
Contact material:
3/16" silver cadmium oxide, gold flashed Std.
Gold Diffused also available.
50 milliohms maximum initial resistance at rated current
12 V @ 100 Milliamps
Contact resistance:
Minimum Load:
TIMING
Operate time:
Release time:
15 mS or less at nominal voltage.
10 mS or less at nominal Voltage.
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Pole to pole:
Contacts to frame:
Insulation resistance:
1500 V rms
500 V rms
1500 V rms
1500 V rms
1,000 Megohms min. @ 500 VDC
TEMPERATURE
Ambient Temperature (Operating):
Non operating storage:
-45˚C to +55˚C (AC), -45˚C to +70˚C (DC)
-45˚C to +105˚C
SHOCK RESISTANCE
Operating:
Non operating:
5 G's,
20 G's
VIBRATION RESISTANCE
Operating:
5 G's, 10 Hz to 55 Hz
MISCELLANEOUS
Enclosure:
Insulation material:
Operating Position:
Terminals:
Weight:
Plastic dust cover with octal plug.
Molded plastic
Any
8 or 11 pin octal plug-in
3 1/2 ozs. 99.2 g approx.
SEE SECTION 10
FOR
MATING SOCKETS
PAGE 17
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
OCTAL STYLE 10 AMP GENERAL PURPOSE RELAY
A314 & 250
Struthers-Dunn
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW
DUAL MARKED PART NUMBERS
SERIES A314
CLASS 250CP
CONTACT
CONFIGURATION
AC OPERATED
A314XAX48P-24A
A314XAX48P-120A
A314XBX48P-24A
A314XBX48P-120A
A314XBX48P-240A
W250ACPX-3
W250ACPX-4
W250ACPX-8
W250ACPX-9
W250ACPX-10
SPDT
SPDT
DPDT
DPDT
DPDT
A314XCX48P-24A
A314XCX48P-120A
A314XCX48P-240A
W250ACPX-13
W250ACPX-14
W250ACPX-15
3PDT
3PDT
3PDT
Struthers-Dunn
CROSS REFERENCE TO
POTTER &
IDEC
BRUMFIELD
COIL Measured @ 25˚C
NOMINAL NOMINAL
NOMINAL
RESISINPUT
POWER
TANCE
VOLTAGE
24 VAC
120VAC
24 VAC
120VAC
240 VAC, 60 Hz
220 VAC, 50 Hz
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
-
2.0VA
2.0VA
2.75VA
2.75VA
-
2.75VA
2.75VA
2.75VA
-
2.75VA
*
KRPA5AG (or GF) -24
KRPA5AG (or GF) -120
KRPA11AG (or GF) -24 RR2P-U-AC24V
KRPA11AG (or GF) -120 RR2P-U-AC120V
KRPA11AG (or GF) -240 RR2P-U-AC240V
KRPA14AG (or GF) -24 RR3PA-U-AC24V
KRPA14AG (or GF) -120 RR3PA-U-AC120V
KRPA14AG (or GF) -240 RR3PA-U-AC240V
AC OPERATED WITH INDICATOR LAMP
A314XBX48PL-24A W250ANCPX-26
A314XBX48PL-120A W250ANCPX-27
A314XBX48PL-240A W250ANCPX-28
DPDT
DPDT
DPDT
A314XCX48PL-24A W250ANCPX-29
A314XCX48PL-120A W250ANCPX-30
A314XCX48PL-24OA W250ANCPX-31
3PDT
3PDT
3PDT
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
2.0VA
2.0VA
2.75VA
KRPA11AN (or NF) -24 RR2P-UL-AC24V
KRPA11AN (or NF) -120 RR2P-UL-AC120V
KRPA11AN (or NF) -240 RR2P-UL-AC240V
2.0VA
2.0VA
2.75VA
KRPA14AN (or NF) -24 RR3PA-UL-AC24V
KRPA14AN (or NF) -120 RR3PA-UL-AC120V
KRPA14AN (or NF) -240 RR3PA-UL-AC240V
DC OPERATED
A314XAX48P-12D
A314XAX48P-24D
A314XBX48P-12D
A314XBX48P-24D
A314XCX48P-12D
A314XCX48P-24D
W250CPX-2
W250CPX-3
W250CPX-6
W250CPX-7
W250CPX-10
W250CPX-11
SPDT
SPDT
DPDT
DPDT
3PDT
3PDT
12 VDC
24 VDC
12VDC
24 VDC
12 VDC
24 VDC
120 Ω
472 Ω
120 Ω
472 Ω
120 Ω
472 Ω
1.2W
1.2W
1.2W
1.2W
1.2W
1.2W
KRPA5DG (or GF) -12
KRPA5DG (or GF) -24
KRPA11DG (or GF) -12
KRPA11DG (or GF) -24
KRPA14DG (or GF) -12
KRPA14DG (or GF) -24
RR2P-U-DC12V
RR2P-U-DC24V
RR3PA-U-DC12V
RR3PA-U-DC24V
24 VDC
24 VDC
472 Ω
472 Ω
1.2 W
1.2 W
KRPA11DN (or NF) -24
KRPA14DN (or NF) -24
RR2P-UL-DC24V
RR3PA-UL-DC24V
DC OPERATED WITH INDICATOR LAMP
A314XBX48PL-24D
A314XCX48PL-24D
W250NCPX-20
W250NCPX-21
DPDT
3PDT
*F = GOLD FLASHED
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
CONTACT RATINGS WITH BLOW-OUT MAGNET
POLES
120 VAC
240 VAC
DPDT
12 AMP
1/3 HP
10 AMP
1/2 HP
30 VDC
10 AMP
150 VDC
3 AMP
RELAYS FOR DC SWITCHING
PART
NUMBERS
CONTACT NO. OF PINS
CONFIGUOCTAL
RATION
STYLE
-
COIL Measured @ 25˚C
NOMINAL
NOMINAL
NOMINAL
INPUT
RESISTANCE
POWER
VOLTAGE
(OHMS)
AC OPERATED WITH BLOW-OUT MAGNET
A314XBX48P69-24A
A314XBX48P69-120A
DPDT
DPDT
8 PIN
8 PIN
24 VAC
120VAC
-
2.0 VA
2.0 VA
120 Ω
472 Ω
10,000 Ω
1.2 W
1.2 W
1.2 W
DC OPERATED WITH BLOW-OUT MAGNET
A314XBX48P69-12D
A314XBX48P69-24D
A314XBX48P69-110D
DPDT
DPDT
DPDT
8 PIN
8 PIN
8 PIN
12 VDC
24 VDC
110 VDC
RELAYS USING MAGNETIC BLOW-OUT MAGNETS ARE NOT AGENCY APPROVED.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 18
SERIES
284
GENERAL PURPOSE 4 POLE 10 AMP PLUG-IN RELAY
The series 284 relay is a extension of the Class 388/283
style relay except it provides for 4PDT contacts, any
one set of contacts capable of switching 10 Amps (total
load of 30 Amps at 120 VAC and 20 Amps at 240 VAC).
This relay has the 3 way terminal design for greater flexibility
in making connections. The 0.187 Spade terminals can be
soldered, plugged into sockets or connected using 3/16"
Q.C. Female connectors.
UL Recognized
File No. E13224
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
0.218
(5.53)
1.50
(38.1)
1.31
(33.3)
1.93
(49.0)
MANUAL PUSH
BUTTON
ACTUATOR (OPTIONAL)
1.87
(47.4)
0.020 Typ.
(.508)
0.28
(7.11)
0.187 Typ.
(4.74)
Struthers-Dunn
ORDERING CODE
Typical Type No.
WIRING DIAGRAM
(VIEWED FROM TERMINAL END)
284 XDX C GLM -240A
Series
284 3 way terminals
10 Amp, 4 pole
Contact Arrangements
XDX (4PDT)
Construction Style
Open, with tapped 6-32 hole - NO CODE
Open, with 6-32 Stud - CODE S
Enclosed, 3 way terminals - CODE C
Options
10 Amp contacts Standard - NO CODE
Gold diffused contacts - CODE G
Indicator Lamp - CODE L
Manual Actuator - CODE M
Printed Circuit Terminals - CODE T
5 Amp contacts (Silver) - CODE Y
Coil Voltage
AC: 6, 12, 24, 48, 120, 240 (Add "A")
DC: 6, 12, 24, 48, 115, 125 (Add "D")
1
5
2
6
3
7
9
10
11
13
4
8
12
14
SEE NEXT PAGE FOR RATINGS & SPECIFICATIONS
PAGE 19
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
GENERAL PURPOSE 4 POLE 10 AMP PLUG-IN RELAY
SERIES
284
UL Recognized
File No. E13224
CONTACT RATINGS
120VAC
30VDC
LOAD
Resistive Motor
Load 80% pF.
10A
240VAC
10A
1/3Hp
10A
1/2Hp
Maximum total load for 4 pole relay is 30 Amps @
120VAC, 20Amps @ 240VAC
GENERAL SPECIFICATIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
AC: 85%, DC: 75% of nominal voltage
measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
15 mS Max. @ Nominal Voltage.
10 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points:
Insulation Resistance:
TEMPERATURE
Temperature Rating:
500 V rms across open contacts
1500 V rms between current carrying
parts
1000 Megohms.min. @ 500 VDC
AC: -45˚C to +50˚C @ Rated Operation.
(+65˚C for open style)
DC: -45˚C to +70 ˚C
+85˚C for open style)
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear polycarbonate
5.0 oz. approx..
COIL SPECIFICATIONS @ 25˚C
Nominal
Voltage
6
12
24
48
120AC or
115-125DC
240AC*
Current (MA)
Resistance
Resistance
Ohms ± 10% Ohms ± 10%
AC
AC
DC
DC
3
30
200
560
120
12
100
230
48
480
50
115
1920
25
870
8200
13-15
31
4700
-*
12
-*
Power
Consumption
AC
DC
3.4VA 1.2W
3.4VA 1.2W
3.4VA 1.2W
3.4VA 1.2W
3.4VA 1.2W
3.4VA
1.2W
NOTE: * For 220-250VDC coils use a 8,200 Ω, 5 Watt resistor in series with
110-125 VDC relays
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 20
CLASS
GENERAL SPECIFICATIONS
388 & A283
MANUFACTURED UNDER
The Class 388 & 283 general purpose relays are available in
a wide choice of AC or DC voltages with Indicator Lamp, Push to test
QUALITY SYSTEM
button and other options. Plug-in style relays have 3-way pierced
ISO
9002 & QS 9000
terminals. While spaced for standard plug-in Socket mounting.
The flat terminals (0.187 x 0.020) also accept quick connect
receptacles or direct soldering.
Recognized Component mark for
Canada and the United States.
C
US
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
UL Recognized
File No. E43641
NEW!
FLANGE MOUNT
PLUG-IN
P.C. MOUNT
CONTACT RATINGS TABLE
TOP FLANGE MOUNT
TYPICAL OPERATING CHARACTERISTICS
(For DC Voltage types only).
POLES
120 VAC
240 VAC
1 POLE
13 AMP
1/3 HP
13 AMP
1/2 HP
2 POLE
13 AMP
1/3 HP
13 AMP
1/3 HP
3 POLE
28 VDC
POLES
SPDT
DPDT
13 AMP
MIN. OPERATE
mW
(SENSITIVITY)
125
250
375
12 AMP
1/2 HP
12 AMP
OPERATE TIME
(Milliseconds
maximum.)
18.0
20.0
24.0
11 AMP
1/2 HP
11 AMP
RELEASE TIME
(Milliseconds
Maximum.)
30.0
28.0
26.0
3PDT
WIRING DIAGRAMS
Viewed from terminal end
1
4
2
5
3
6
1
4
2
5
7
8
9
7
8
B
A
SPDT
A
3
6
1
4
2
5
3
6
9
7
8
9
B
A
DPDT
B
3PDT
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SEE SECTION 10 FOR MATING SOCKETS
PAGE 21
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
GENERAL SPECIFICATIONS
388 & A283
SPECIFICATIONS CLASS 388 & 283 RELAYS
COIL
Pull-in voltage:
80% of nominal voltage or less. for DC coils.
85% of nominal voltage or less for AC coils.
10% of nominal voltage or more.
± 10 % Measured at 25˚C
1.2 Watts for DC coils, 2 VA to 2.75 VA for AC coils
Class "B" (130˚C per UL std. 1446)
Capability of DC coils 3.0 Watts max.
Continuous
Dropout voltage:
Resistance:
Coil power
Insulation System:
Maximum coil dissipation:
Duty:
CONTACTS
Contact material:
Contact resistance:
3/16" silver cadmium oxide, gold flashed.
50 Milliohms maximum initial resistance
at rated current
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Pole to pole
Contacts to frame:
Insulation resistance:
2000 V rms
500 V rms
2000 V rms
2000 V rms
1000 Megohms @ 500 VDC
TEMPERATURE
Operating:
Storage
-30˚C to +50˚C (AC), -30˚C to +65˚C (DC)
-30˚C to 100˚C
LIFE EXPECTANCY
Electrical:
Mechanical:
100,000 Operations @ rated AC load
5,000,000 Operations @ No load
MISCELLANEOUS
Operating Position:
Insulation material:
Enclosure:
Terminals:
Any
Molded plastic
Clear Polycarbonate dust cover
3/16" solder/plug-in, Printed Circuit terminals
other terminals available: .205 x .032, .250 x .032
on special order. Consult Factory.
3.1 oz.. (88 g approx. with cover).
Weight:
OPTIONAL
1.41
(35.8)
TOP FLANGE COVER
IS AVAILABLE ON
SPECIAL ORDER.
CONSULT FACTORY.
2.53
(64.29)
1.90Max.
(48.4)
1.40Max.
(35.5)
.500
(12.7)
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 22
CLASS
388 & A283
SQUARE BASE RELAY, SOLDER/PLUG-IN
Recognized Component mark for
Canada and the United States.
CLASS 388 & 283 RELAY
C
13 AMP CONTACT RATING
US
UL Recognized
File No. E43641
OPTIONAL INDICATOR LAMP AND PUSH TO TEST
BUTTON AVAILABLE ON SPECIAL ORDER.
*
MANUFACTURED UNDER
QUALITY SYSTEM
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
ISO 9002 & QS 9000
OUTLINE DIMENSIONS
Dimensions shown are in "INCH" and (Millimeter)
1.53 Max.
(38.8)
.187 x .020
(4.76 x 0.51)
QC Terminals Typical
1.90Max.
(48.4)
1
4
2
5
3
6
7
8
9
1.40Max.
(35.5)
A
B
.28 Typ.
(7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
Struthers-Dunn
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW
DUAL MARKED PART NUMBERS
Struthers-Dunn
CLASS 388CP
CLASS A283
CONTACT
CONFIGURATION
COIL Measured @ 25˚C
NOMINAL NOMINAL
RESISTANCE POWER
NOMINAL
INPUT
VOLTAGE
CROSS REFERENCE TO
POTTER & BRUMFIELD
IDEC
AC OPERATED
W388ACPX-3
W388ACPX-4
W388ACPX-5
A283XAXC-24A
A283XAXC-120A
A283XAXC-240A
SPDT
SPDT
SPDT
W388ACPX-8
W388ACPX-9
W388ACPX-10
A283XBXC-24A
A283XBXC-120A
A283XBXC-240A
DPDT
DPDT
DPDT
W388ACPX-13
W388ACPX-14
W388ACPX-15
A283XCXC-24A
A283XCXC-120A
A283XCXC-240A
3PDT
3PDT
3PDT
DC OPERATED
W388CPX-2
W388CPX-3
W388CPX-6
W388CPX-7
W388CPX-8
W388CPX-10
W388CPX-11
A283XAXC-12D
A283XAXC-24D
A283XBXC-12D
A283XBXC-24D
A283XBXC-110D
A283XCXC-12D
A283XCXC-24D
SPDT
SPDT
DPDT
DPDT
DPDT
3PDT
3PDT
24 VAC
120VAC
240 VAC, 60 Hz
220 VAC, 50 Hz
24 VAC
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
24 VAC
120 VAC
240VAC, 60Hz
220 VAC, 50Hz
-
2.0VA
2.0VA
2.0VA
2.0VA
2.0VA
2.0VA
-
2.75VA
2.75VA
2.75VA
-
2.75VA
12 VDC
120 Ω
24 VDC
472 Ω
12 VDC 120 Ω
24 VDC
472 Ω
110VDC 10,000 Ω
12 VDC
120 Ω
24 VDC
472 Ω
1.2W
1.2W
1.2W
1.2W
1.2W
1.2W
1.2W
KUP5A15 (or F) - 24
KUP5A15 (or F) - 120
KUP5A15 (or F) - 240
RR1BA-U-AC24V
RR1BA-U-AC120V
RR1BA-U-AC240V
KUP11A15 (or F) - 24
KUP11A15 (or F) - 120
KUP11A15 (or F) - 240
RR2BA-U-AC24V
RR2BA-U-AC120V
RR2BA-U-AC240V
KUP14A15 (or F) - 24
KUP14A15 (or F) - 120
KUP14A15 (or F) - 240
RR3B-U-AC24V
RR3B-U-AC120V
RR3B-U-AC240V
KUP5D15 (or F) - 12
KUP5D15 (or F) - 24
KUP11D15 (or F) - 12
KUP11D15 (or F) - 24
KUP11D15 (or F) - 110
KUP14D15 (or F) - 12
KUP14D15 (or F) - 24
RR1BA-U-DC12V
RR1BA-U-DC24V
RR2BA-U-DC12V
RR2BA-U-DC24V
RR2B-U-DC110V
RR3B-U-DC12V
RR3B-U-DC24V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE GENERAL SPECIFICATIONS & WIRING DIAGRAMS FOR CLASS 388 & A283 RELAYS.
F = GOLD FLASHED
SEE SECTION 10 FOR MATING SOCKETS
PAGE 23
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
SQUARE BASE FLANGE MOUNT RELAYS
Recognized Component mark for
Canada and the United States.
C
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
US
UL Recognized
File No. E43641
388 & A283
FLANGE MOUNT RELAY
13 AMP CONTACT RATING
.187 Q.C. /SOLDER TERMINALS
TOP FLANGE COVER AVAILABLE ON
SPECIAL ORDER. CONSULT FACTORY
OPTIONAL INDICATOR LAMP AND PUSH TO TEST
BUTTON AVAILABLE ON SPECIAL ORDER.
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
MANUFACTURED UNDER
QUALITY SYSTEM
ISO 9002 & QS 9000
2.90Max.
(73.8)
2.50
(63.5)
.187 x .020
(4.76 x 0.51)
QC Terminals Typical
1.53 Max.
.625 Typ. (38.8)
(15.8)
.156
(3.9)
.187
(4.76)
1.90Max.
(48.4)
1.40Max.
(35.5)
1
4
2
5
3
6
7
8
9
A
B
.28 Typ.
(7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
Struthers-Dunn
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW
CROSS REFERENCE TO
COIL Measured @ 25˚C
DUAL MARKED PART NUMBERS
NOMINAL
NOMINAL
CONTACT
POTTER &
Struthers-Dunn
RESIS- NOMINAL
IDEC
INPUT
CONFIGURATION
BRUMFIELD
TANCE POWER
W388CQ
A283
VOLTAGE
(OHMS)
AC OPERATED
RR1BA-US-AC120V
KUP5A55 (or F) - 120
W388ACQX-4 A283XAXC1-120A
SPDT
2.0VA
120 VAC
RR1BA-US-AC240V
KUP5A55 (or F) - 240
W388ACQX-5 A283XAXC1-240A
SPDT
240 VAC, 60Hz
2.0VA
220 VAC, 50 Hz
KUP11A55 (or F) - 120 RR2BA-US-AC120V
W388ACQX-9 A283XBXC1-120A
DPDT
2.0VA
120 VAC
KUP11A55 (or F) - 240 RR2BA-US-AC240V
W388ACQX-10 A283XBXC1-240A
DPDT
240 VAC. 60 Hz
2.0VA
220 VAC, 50 Hz
KUP14A55 (or F) - 120 RR3B-US-AC120V
W388ACQX-14 A283XCXC1-120A
3PDT
2.75VA
120 VAC
KUP14A55 (or F) - 240 RR3B-US-AC240V
W388ACQX-15 A283XCXC1-240A
3PDT
240VAC, 60Hz
2.75VA
220 VAC, 50Hz
DC OPERATED
RR1BA-US-DC12V
KUP5D55 (or F) - 12
A283XAXC1-12D
W388CQX-2
SPDT
1.2W
12 VDC
120
RR1BA-US-DC24V
KUP5D55 (or F) - 24
A283XAXC1-24D
W388CQX-3
SPDT
1.2W
24 VDC
472
RR2BA-US-DC12V
KUP11D55 (or F) - 12
A283XBXC1-12D
W388CQX-6
DPDT
1.2W
12 VDC
120
RR2BA-US-DC24V
KUP11D55 (or F) - 24
A283XBXC1-24D
W388CQX-7
DPDT
1.2W
24 VDC
472
RR3B-US-DC24V
KUP14D55 (or F) - 24
W388CQX-11 A283XCXC1-24D
3PDT
1.2W
24 VDC
472
F = GOLD FLASHED
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE GENERAL SPECIFICATIONS & WIRING DIAGRAMS FOR CLASS 388 & A283 RELAYS.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 24
CLASS
388B & A283 SQUARE BASE RELAYS WITH MAGNETIC BLOWOUT
Recognized Component mark for
Canada and the United States.
CLASS 388B & 388DB
SQUARE BASE PLUG-IN STYLE
WITH MAGNETIC BLOWOUT FOR
DC SWITCHING.
RATED 3 & 10 AMPS AT 150 VDC
C
US
*
UL Recognized
File No. E43641
& E13224
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown are in "INCHES" and (Millimeters)
TOP FLANGE COVER AVAILABLE ON
SPECIAL ORDER. CONSULT FACTORY
MANUFACTURED UNDER
QUALITY SYSTEM
ISO 9002 & QS 9000
1.53 Max.
(38.8)
.187 x .020
(4.76 x 0.51)
QC Terminals Typical
1.90Max.
(48.4)
1
4
2
5
3
6
7
8
9
1.40Max.
(35.5)
B
A
.28 Typ.
(7.1)
The Class 388B/388DB style relays have the same load
specifications as the 388/283 enclosed plug-in style relays
plus the additional load ratings charted on this page.
See 388& A283 General specifications.
WIRING DIAGRAM
Viewed from terminal end
1
4
DC LOAD RATINGS
DPDT FIG. "A"
RESISTIVE
3 AMPS 150VDC
SPDT-N.O. -DM FIG. "B"
10 AMPS 150VDC
ALSO
AVAILABLE
RESISTIVE
3
6
7
9
A
B
DPST-NO & DPST-NC CONTACT VERSIONS
WITH BLOWOUT MAGNETS NOW UL APPROVED
@ 5 AMPS, 150 VDC.
DPDT
FIG. "A"
4
6
A
B
SPST-NO-DM
FIG. "B"
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
Struthers-Dunn
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
RELAYS CAN BE ORDERED EITHER BY MAGNECRAFT OR STRUTHERS-DUNN PART NUMBERS LISTED BELOW
COIL Measured @ 25˚C
DUAL MARKED PART NUMBERS WIRING CONTACT
CROSS REFERENCE
NOMINAL NOMINAL NOMINAL
CONFIGUTO
Struthers-Dunn DIAG.
INPUT
RESISTANCE
RATION
FIG.
W388B
A283
(OHMS) POWER P O T T E R / B R U M F I E L D
VOLTAGE
AC OPERATED WITH BLOWOUT MAGNET (3 AMP CONTACTS)
W388ABCPX-5
A283XBX69C-120A
"A"
DPDT
-
2.0VA
KUEP-11A15-120
120
472
10,000
1.2W
1.2W
1.2W
KUEP-11D15-12
KUEP-11D15-24
KUEP-11D15-110
2.OVA
KUEP-3A15-120
1.2W
1.2W
1.2W
KUEP-3D15-12
KUEP-3D15-24
KUEP-3D15-110
120 VAC
DC OPERATED WITH BLOWOUT MAGNET (3 AMP CONTACTS)
W388BCPX-2
W388BCPX-3
W388BCPX-5
A283XBX69C-12D
A283XBX69C-24D
A283XBX69C-110D
"A"
"A"
"A"
DPDT
DPDT
DPDT
12 VDC
24VDC
110 VDC
AC OPERATED WITH BLOWOUT MAGNET (10 AMP CONTACTS)
W388ADBCPX-5 A283HXX69C-120A
'B'
SPST-NO (DM) 120 VAC
-
DC OPERATED WITH BLOWOUT MAGNET (10 AMP CONTACTS)
W388DBCPX-2
W388DBCPX-3
W388DBCPX-5
A283HXX69C-12D
A283HXX69C-24D
A283HXX69C-110D
'B'
'B'
'B'
SPST-NO (DM) 12 VDC
SPST-NO (DM) 24 VDC
SPST-NO (DM) 110 VDC
120
472
10,000
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10 FOR MATING SOCKETS
PAGE 25
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
GENERAL SPECIFICATIONS
389
The Class 389 relays are high quality general purpose relays, designed to switch
larger loads without increasing overall size. One, two and three pole relays are
available with a choice of Indicator lamp, Push to test button and various contact
combinations. Double make and double break styles are available only with a one
pole style but is capable of switching larger loads and are especially well suited for
switching motor loads. These relays are available in the 30 Amp contact range.
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
Recognized Component mark for
Canada and the United States.
C
US
MANUFACTURED UNDER
QUALITY SYSTEM
ISO 9002 & QS 9000
UL Recognized
File No. E43641
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
FLANGE MOUNT
WIRING DIAGRAMS
Viewed from terminal end
1
4
2
5
7
8
3
6
9
B
A
SPDT
1
4
2
5
7
8
A
3
6
1
4
2
5
9
7
8
B
A
DPDT
3
6
9
1
3
4
6
4
6
A
B
A
B
B
SPDT-NC-NO(DB-DM)
3PDT
SPST-NO-(DM)
CLASS 389 DIELECTRIC WITHSTANDING VOLTAGES (VRMS)
1, 2 & 3 POLE STYLE RELAYS
POINTS WHERE VOLTAGE IS APPLIED
SPDT
DPDT
ACROSS OPEN CONTACTS
POLE- TO- ADJACENT POLE
COIL TO FRAME
COIL TO CONTACTS
CONTACT TO FRAME
CONTACTS TO METAL
MOUNTING PLATE ( COVER INSTALLED)
COIL TO METAL MOUNTING PLATE
(COVER INSTALLED)
1000
1600
2200
1600
1000
2200
1600
2200
1600
1000
1600
1600
1600
1600
2200
2200
1600
2200
2200
2200
CLASS 389D DIELECTRIC WITHSTANDING VOLTAGES VRMS)
SPDT-NC-NO (DB-DM), SPST-NO - (DM)
POINTS WHERE VOLTAGE IS APPLIED
ACROSS OPEN CONTACTS
COIL TO FRAME
COIL TO CONTACTS
CONTACT TO FRAME
CONTACTS TO METAL
MOUNTING PLATE ( COVER INSTALLED)
COIL TO METAL MOUNTING PLATE
(COVER INSTALLED)
ENCLOSED STYLE
3PDT
NEW!
1500
1600
2200
1600
2200
2200
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
TOP FLANGE MOUNT
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 26
CLASS
GENERAL SPECIFICATIONS
389
SPECIFICATIONS CLASS 389 RELAYS
COIL
Pull-in voltage:
80% of nominal voltage or less. for DC coils.
85% of nominal voltage or less for AC coils.
10% of nominal voltage or more.
± 10 % Measured at 25˚C
1.44 Watts for DC coils, 2VA to 3.5VA for AC coils
Capability of DC coils 2.5 Watts max.
Continuous
Class "B" coil system. (130˚C per UL std. 1446).
Dropout voltage:
Coil resistance:
Nominal power:
Maximum coil dissipation:
Duty:
Insulation System:
CONTACTS
Contact material:
Contact Gap:
Contact resistance:
1/4" silver cadmium oxide, gold flashed.
.015 min. is standard.
50 Milliohms maximum initial resistance at rated current
TIMING
Operate time, (excluding bounce):
Release time, (excluding bounce):
20 milliseconds max.at nominal voltage.
20 milliseconds max.at nominal voltage.
DIELECTRIC STRENGTH
Insulation resistance:
1,000 Megohms min. @ 500 VDC
TEMPERATURE
Operating:
Storage:
-30˚C to +50˚C (AC), -30˚C to +65˚C (DC)
-30˚C to 100˚C
LIFE
Electrical:
Mechanical:
100,000 at rated load.
5 Million Operations no load
MISCELLANEOUS
Enclosure:
Operating Position:
Insulation material:
Terminals:
Clear Polycarbonate dust cover
Any
Molded plastic
1/4" x .032 Q.C. Terminals suitable for solder or Q.C. connectors,
also available with Printed Circuit terminals. (.090 x .032)
3.3 oz.. (94 g approx. with cover).
Weight:
ALSO
AVAILABLE
OPTIONAL
The 300 series was developed as a 600 Volt relay that would accept 1/4" booted
terminals. Its extra spacing permits contact gaps to 2 millimeters when required.
This increases dielectric strength across open contacts to 2500 Volts RMS.
Consult factory for details or additional information.
1.41
(35.8)
TOP FLANGE COVER
IS AVAILABLE ON
SPECIAL ORDER.
CONSULT FACTORY.
2.53
(64.29)
1.90Max.
(48.4)
1.40Max.
(35.5)
.500
(12.7)
PAGE 27
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
GENERAL CONTACT RATINGS
389
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E43641
1, 2 & 3 POLE NEMA PILOT DUTY CONTACT RATINGS
MAXIMUM CURRENT, AMPERES
THERMAL
NEMA
120 VOLTS
CONTINUOUS
CONTACT
50/60Hz
TEST CURRENT
CODE
MAKE BREAK
DESIGNATION AMPERES
60
30
30
10
5
5
A600
B300
B600
240 VOLTS
50/60Hz
MAKE
6.00
3.00
3.00
30
15
15
BREAK
3.00
1.50
1.50
480 VOLTS
50/60Hz
600 VOLTS
50/60Hz
MAKE BREAK MAKE
BREAK
MAKE
BREAK
15
1.50
12
1.20
0.75
0.75
6
0.06
7200
3600
3600
720
360
360
CLASS 389D LOAD RATINGS
CLASS 389 LOAD RATINGS
ENCLOSED STYLE 1, 2 and 3 POLE
NO. OF
POLES
1
P
O
L
E
2
P
O
L
E
3
P
O
L
E
CURRENT
OR
HORSEPOWER
TYPE
OF
LOAD
LOAD
VOLTAGE
LOAD
VOLTAGE
FREQUENCY
13A
20A
25A
5A
1HP
1-1/2HP
1HP
660VA
915VA
960VA
765VA
B600
28
15
300
600
120
208/240
480/600
120
208
240
480/600
DC
DC
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60Hz
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
MOTOR
MOTOR
MOTOR
PILOT DUTY
PILOT DUTY
PILOT DUTY
PILOT DUTY
PILOT DUTY
13A
20A
25A
5A
1HP
1-1/2HP
1HP
660VA
915VA
960VA
765VA
B600
28
15
300
600
120
208/240
480/600
120
208
240
460/600
DC
DC
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60Hz
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
MOTOR
MOTOR
MOTOR
PILOT DUTY
PILOT DUTY
PILOT DUTY
PILOT DUTY
PILOT DUTY
28
28
15
150
250
300
120/208/240
240
120
120/240
208
DC
DC (NO)
DC
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60Hz
50/60 Hz
50/60 Hz
50/60Hz
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
RESISTIVE
MOTOR
MOTOR
MOTOR
PILOT DUTY
PILOT DUTY
PILOT DUTY
13A
15A
20A
20A
**15A
*10A
1/2HP
1HP
3/4HP
470VA
445VA
B300
MAXIMUM
VOLT-AMPERES
ENCLOSED
CURRENT
OR
NO. OF
POLES HORSEPOWER
1
30A
30A
10A
1HP
1-1/2HP
765VA
915VA
960VA
A600
P
O
L
E
LOAD
VOLTAGE
STYLE
LOAD
VOLTAGE
FREQUENCY
28
300
600
120
200 thru 600
120
208
240,480,600
DC
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
TYPE
OF
LOAD
RESISTIVE
RESISTIVE
RESISTIVE
MOTOR
MOTOR
PILOT DUTY
PILOT DUTY
PILOT DUTY
PILOT DUTY
CLASS 389 BALLAST LOAD RATINGS
NO. OF
POLES
ENCLOSED
STYLE
1
POLE
20 AMPS, 277VAC, 50/60Hz
2
POLE
20 AMPS, 277VAC, 50/60Hz
3
POLE
20 AMPS,150VAC, 50/60Hz
6-2/3 AMPS, 277VAC, 50/60Hz
DOUBLE BREAK DOUBLE MAKE (1 FORM "X" & "Z")
1
POLE
25 AMPS, 277VAC, 50/60Hz
Not CSA rated with ** are UL Appliance rated.
All other ratings not so marked are industrial rated
* CSA rating only, not UL
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 28
CLASS
SQUARE BASE, 30 AMP POWER RELAY
389
CLASS 389D
Recognized Component mark for
Canada and the United States.
1/4" Q.C. MALE TAB TERMINALS
FOR USE WITH FEMALE QUICK
CONNECT TERMINALS OR
SUITABLE FOR SOLDERING.
C
US
UL Recognized
File No. E43641
*
TOP FLANGE COVER AVAILABLE ON
SPECIAL ORDER. CONSULT FACTORY
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OPTIONAL INDICATOR LAMP AND PUSH TO TEST
BUTTON AVAILABLE ON SPECIAL ORDER.
MANUFACTURED UNDER
QUALITY SYSTEM
ISO 9002 & QS 9000
OUTLINE DIMENSIONS
Dimensions shown in Inches and (millimeters).
2.90Max.
(73.8)
.250 x .032
(6.35 x .891)
QC Terminals Typical
2.50
(63.5)
1.53 Max.
.625 Typ. (38.8)
(15.8)
FLANGE COVER
.156
(3.9)
.187
(4.76)
1.90Max.
(48.4)
1.40Max.
(35.5)
1
4
2
5
3
6
7
8
9
A
B
.28 Typ.
(7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
CONTACT
CONFIGURATION
CONTACT
RATING
W389ADCX-4
W389ADCX-5
SPST-NO-(DM)
SPST-NO-(DM)
30 AMP
30 AMP
W389ADZCX-3
SPDT-NO-NC
(DM-DB)
SPDT-NO-NC
(DM-DB)
30 AMP
SPST-NO-(DM)
SPST-NO-(DM)
SPDT-NO-NC
(DM-DB)
SPDT-NO-NC
(DM-DB)
PART
NUMBERS
COIL Measured @ 25˚C
CROSS REFERENCE
NOMINAL
NOMINAL
TO
NOMINAL
INPUT
RESISTANCE
POTTER & BRUMFIELD
POWER
VOLTAGE
(OHMS)
AC OPERATED
W389ADZCX-4
120 VAC
240VAC, 60Hz
220 VAC, 50Hz
-
2.75VA
-
2.75VA
24 VAC
-
3.75VA
120VAC
-
3.75VA
30 AMP
30 AMP
12 VDC
24 VDC
100
400
1.44W
1.44W
30 AMP
12 VDC
100
1.44W
30 AMP
24VDC
400
1.44W
KUMP3A5G-120
KUMP3A5G-240
KUMP6A5G-24
KUMP6A5G-120
30 AMP
DC OPERATED
W389DCX-2
W389DCX-3
W389DZCX-2
W389DZCX-3
KUMP3D5G-12
KUMP3D5G-24
KUMP6D5G-12
KUMP6D5G-24
EXCEPTION TO CROSS REFERENCE: MAGNECRAFT RELAYS ARE RATED AT 3O AMPS , P&B 15 AMPS
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE CLASS 389 GENERAL SPECIFICATIONS AND WIRING DIAGRAMS.
PAGE 29
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
SQUARE BASE, 25 AMP POWER RELAY
Recognized Component mark for
Canada and the United States.
C
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
US
389
CLASS 389 RELAY
1/4" MALE TAB TERMINALS FOR
USE WITH FEMALE QUICK CONNECT
TERMINALS OR SUITABLE FOR SOLDERING
UL Recognized
File No. E43641
TOP FLANGE COVER AVAILABLE ON
SPECIAL ORDER. CONSULT FACTORY
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OPTIONAL INDICATOR LAMP AND PUSH TO TEST
BUTTON AVAILABLE ON SPECIAL ORDER.
MANUFACTURED UNDER
QUALITY SYSTEM
OUTLINE DIMENSIONS
ISO 9002 & QS 9000
Dimensions shown are in INCH and (Millimeter)
2.90Max.
.250 x .032
(73.8)
(6.35 x .891)
2.50
QC Terminals Typical
(63.5)
1.53 Max.
.625 Typ. (38.8)
(15.8)
.156
(3.9)
.187
(4.76)
1.90Max.
(48.4)
1.40Max.
(35.5)
1
4
2
5
3
6
7
8
9
A
B
.28 Typ.
(7.1)
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
PART NUMBERS
FLANGE COVER
CONTACT
CONFIGURATION
CONTACT
RATING
COIL Measured @ 25˚C
NOMINAL
NOMINAL
NOMINAL
INPUT
RESISTANCE
POWER
VOLTAGE
(OHMS)
CROSS REFERENCE
TO
POTTER & BRUMFIELD
AC OPERATED
W389ACX-4
W389ACX-8
W389ACX-9
W389ACX-10
SPDT
DPDT
DPDT
DPDT
25 AMP
25 AMP
25 AMP
25 AMP
W389ACX-14
W389ACX-15
3PDT
3PDT
20 AMP
20 AMP
120 VAC
24VAC
120 VAC
240 VAC, 60 Hz
220 VAC, 50 Hz
120 VAC
240 VAC. 60 Hz
220 VAC, 50 Hz
KUHP5A51-120
KUHP11A51-120
KUHP11A51-120
KUHP11A51-120
-
2.75VA
2.75VA
2.75VA
-
2.75VA
2.75VA
-
-
2.75VA
-
100
400
100
400
100
400
1.44W
1.44W
1.44W
1.44W
1.44W
1.44W
KUHP5D51-12
KUHP5D51-24
KUHP11D51-12
KUHP11D51-24
-
DC OPERATED
W389CX-2
W389CX-3
W389CX-7
W389CX-8
W389CX-12
W389CX-13
SPDT
SPDT
DPDT
DPDT
3PDT
3PDT
25 AMP
25 AMP
25 AMP
25 AMP
20 AMP
20 AMP
12 VDC
24 VDC
12VDC
24VDC
12 VDC
24 VDC
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE CLASS 389 GENERAL SPECIFICATIONS AND WIRING DIAGRAMS.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 30
CLASS
25 AMPS METAL ENCLOSED POWER RELAY
97
CLASS 97 POWER RELAY
PLUG-IN OR SIDE STUD MOUNT
UL Recognized
File No. E43641
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeter)
STUD MOUNT
1.60
(40.6)
1.52
(38.6)
PLUG-IN,
PLAIN COVER,
NO STUD
3 Standoffs on Stud Mount
Covers only. (Typical)
0.40
(10.1)
1.52
(38.6)
1.52
(38.6)
8-32
Stud
2.06 Max.
(52.3)
1.21
(30.7)
.310
(7.8)
.250 x .030 Q.C.
Terminal (Typical)
1.56
(39.7)
3
.110 x .010 Q.C.
Coil Terminal (Typical)
1.56
(39.7)
5
4
6
3
7
1.56
(39.7)
1
7
1.56
(39.7)
2
9
9
8
8
COIL Measured @ 25˚C
Nominal
Nominal
Nominal
Input
Resistance Power
Voltage
(Ohms)
STUD MOUNTING STYLE
W97ACSX-3
120 VAC
8 VA
W97ACSX-4
240 VAC, 60 HZ
8 VA
220 VAC, 50 HZ
W97CSX-1
12 VDC
50
2.5 W
W97CSX-2
24 VDC
200
2.5 W
PART
NUMBERS
PLAIN COVER, PLUG-IN (NO STUD)
W97CPX-1
W97CPX-2
2
5
10
10
W97ACPX-2
W97ACPX-3
W97ACPX-4
4
1
24 VAC
120 VAC
240 VAC, 60 HZ
220 VAC, 50 HZ
12 VDC
24 VDC
50
200
6
WIRING SCHEMATIC
Viewed from Terminal End
3
4
1
7
8
5
6
2
9
10
8 VA
8 VA
8 VA
2.5 W
2.5 W
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 31
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
METAL ENCLOSED, 25 AMP - 2 FORM "Z" CONTACTS
CLASS
97
SPECIFICATIONS FOR CLASS 97
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Maximum Power
Minimum Power:
Duty
Resistance
AC, 85% of Nominal Voltage or less
DC, 75% of Nominal Voltage or less
110% of nominal voltage
3 Watts
1.6 Watts
Continuous
±10%
CONTACTS
Contact Configuration:
Contact Material:
Contact Resistance:
DPDT-NC-NO (DB-DM)
Silver Alloy
50 Milliohms max. (Initial)
Contact Rating:
25 Amps @ 240 VAC Resistive.
25 Amps @ 277 VAC Resistive.
1 HP @ 120 VAC, 2Hp @ 240 VAC
25 Amps Resistive @ 28 VDC.
TIMING
Operate Time:
Release Time:
35 mS Max. @ Nominal Voltage.
35mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
Pole to Pole:
Contact to Frame:
Insulation Resistance:
2000 V rms
1500 V rms
2000 V rms
2000 V rms
500 VDC Exceeds 100 Megohms min.
TEMPERATURE
Operating:
-35˚C to +70˚C @ Rated Operation.
VIBRATION RESISTANCE
Functional:
5g's; 10 to 55 Hz,
SHOCK RESISTANCE
Functional:
10 g's
LIFE EXPECTANCY
Mechanical (No Load):
Electrical (Rated Load):
Max. Cycle Rate:
1 Million Operations
100,000 Operations
1800 per hour
MISCELLANEOUS
Terminals:
Enclosure:
Operating Position:
Weight:
All Terminals on Stud mounted relays are
1/4" x .032 Quick Connect Tabs. Plug-in
relays have 1/4" x .032 Quick Connect
Tabs and .110 Taper Coil Terminals.
Plated Steel
Any
259.4 grams
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 32
SERIES
219
300 VOLT GENERAL PURPOSE PLUG-IN RELAY
THE SERIES 219 GENERAL PURPOSE INDUSTRIAL PLUG-IN RELAYS FEATURE
12 PIN AND 14 PIN BASES. THE COIL IS ENCAPSULATED FOR PROTECTION.
NUCLEAR QUALIFIED VERSIONS ARE AVAILABLE. CONSULT FACTORY.
UL Recognized
File No. E13224
OPTIONAL MANUAL ACTUATOR
2.625
(66.6)
WIRING DIAGRAMS
BOTTOM VIEW
.250
(6.35)
219XBXP
(DPDT )
6
1
7
12
2.593
(65.5) 3.406
(86.5)
219BBXP
(DPDT + 2 N.O.)
.435
(11)
LOCKING
CLIP
2
3
4
5
6
11
10
9
8
7
1
0.10 Dia. x .435 (2.54 x 11)
Typical of all Pin Dimensions 12
6
1
7
12
1.468
(37.2)
219ABAP
(DPDT + 1NO & 1 NC )
MODELS AVAILABLE
12 PIN
CONTACTS
DPDT + 2 NO
219BBXP
DPDT
219XBXP
219ABAP DPDT + 1 NO & 1 NC
14 PIN
CONTACTS
219XDXP
219FXXP
219DXBP
4PDT
6P-NO
4P-NO + 2P-NC
6
1
7
12
Make before break and other Contact configurations available
limited only by the number of terminal pins.Contact Factory.
OPTIONAL MANUAL ACTUATOR
3.062
(77.77)
.250
(6.35)
2.593
(65.5) 3.406
(86.5)
219FXXP
(6P-NO )
7
1
8
14
219XDXP
(4PDT )
.435
(11)
LOCKING
CLIP
14
13
1
2
12 11
3
4
10
9
8
5
6
7
0.10 Dia. x .435 (2.54 x 11)
Typical of all Pin Dimensions
PAGE 33
7
1
8
14
1.468
(37.2)
219DXBP
(4P-NO + 2P-NC )
7
1
8
14
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
300 VOLT GENERAL PURPOSE PLUG-IN RELAY
219
219 GENERAL SPECIFICATIONS
COIL
Pull-in, min. AC
Pull-in min. DC
Overvoltage, max.
CONTACTS
Contact Material:
85% of Nominal Voltage
80 % of Nominal Voltage
110% of nominal, voltage
Silver Cadmium Oxide, Gold diffused
(Standard)
TIMING
Operate Time:
Release Time:
25 mS Max. @ Nominal Voltage.
20 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points:
Insulation :
1500 V rms
1/4" over surface, 1/8" thru Air
TEMPERATURE
Rated Operation:
-10˚C to +60˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Operating Position:
Weight:
Clear polycarbonate.
Vertical, Contacts Up
8.5 oz. (241 g) approx.
COIL SPECIFICATIONS @ 25˚C
AC RELAYS 50/60 HZ (COIL DATA @ 60HZ Voltage
Nominal
Voltage
6
12
24
120
240
CONTACT RATINGS
BREAK
MAKE CARRY RESISTIVE INDUCTIVE
DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC)
Resistance Milliamperes Impedance Nominal Resistance Milliamperes
Ohms
Cold Hot
Voltage Ohms
Cold Hot
Ohms
± 10%
± 10%
1.1
6
15.5
1500 840
385 304
7.2
4.2
12
63.5
189 147
750 410
27
15.5
24 (28)*
250
77
375 200
96
120
540
40
32
375
62
86
75
2700
2100
17
16
32
20
13,400 115/125* 6200
* Note: Stock 24 Vdc and 115 Vac relays have nameplates stamped 24-28
and 115-125 Vdc respectively. These relays operate at 80% of the lower
voltages and operate within allowable temperature rises at higher voltages.
250 Vdc - Use 125 Vdc relay and series resistor (6000 Ω, 5 W) not supplied.
VOLTS
24 VDC
120 VAC
240 VAC
28 VDC
125 VDC
30A
30A
30A
30A
30A
10A
10A
10A
10A
10A
10A
10A
5A
10A
0.5A
10A
3A
1A
3A
0.1A
For versions with suffix "69"
Permanent Magnet Blowouts
125 VDC
125 VDC
250 VDC
250 VDC
SM
DM
SM
DM
30A
30A
30A
30A
10A
10A
10A
10A
1.5A
4A
0.5A
1.5A
0.5A
1.5A
150 mA
0.5A
Struthers-Dunn
ORDERING CODE
Typical Type No.
219 XBX
P L -24D
Series
219 Industrial plug-in style
Contact Arrangements
XBX (DPDT)
ABA (DPDT + 1 Pole-NO & 1 Pole NC)
BBX (2 Pole-NO & DPDT)
XDX (4 PDT)
FXX (6 Pole-NO)
DXB (4 Pole-NO & 2 Pole-NC)
Standard Features
Polycarbonate Cover- CODE "P"
Optional Features
Indicator Lamp - CODE "L"
Manual Actuator- CODE "M"
130˚C Coil - CODE "U"
Bifurcated Contacts - CODE "33"
Perm. Magnet Blowout- CODE "69"
Coil Voltage
AC: 6, 12, 24, 120, 240 (Add "A")
DC: 6, 12, (24-28), 32, 115/125 (Add "D")
Coil Voltages & Frequencies must be specified.
SEE SECTION 10
FOR
MATING SOCKETS
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 34
SERIES
RSX 1800 INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE
The RSX1800 Series Alarm Relay consists of a pair of 2 pole or 3 pole
relays enclosed in a clear plastic cover. Wired to a 12 Pin Industrial plug.
The relay is wired so that it performs the basic functions of Interfacing between
a alarm point and an alarm light and/or an acoustic sounding device.
The RSX1800 operates from a normally closed trouble contact, while the
RSX1800Z operates from a normally open trouble contact. Either a sustained
or momentary alarm condition will energize the relay when signalled by an
external trouble contact. The Alarm can be allowed to continue until the
trouble has been corrected, at which time it automatically resets.
2.625
(66.6)
2.593
(65.5) 3.406
(86.5)
0.10 Dia. x .435 (2.54 x 11)
Typical of all Pin Dimensions
.435
(11)
LOCKING
CLIP
12
11
10
9
8
7
1
2
3
4
5
6
1.468
(37.2)
COIL DATA
Measured at 25˚C
AC Coils, 50/60Hz AC Coils, 50/60Hz
Ohms mA
Volts
Volts Ohms mA
6
6
35 170
10.7 200
12
12
150
80
41.1 100
24
24
59
560
43
170
120
10 115-125 11,000 10.5
4500
Struthers-Dunn
ORDERING CODE
Typical Type No.
RSX1800 S 120A
Series
219 Industrial plug-in style Alarm relay
5 Amp, 2 Pole
Design for Trouble Contacts
Operate from N.C. trouble contact- CODE S*
Operate from N.O. Trouble contact- CODE Z*
Coil Voltage
AC: 6, 12, 24, 120, (Add "A")
DC: 6, 12, 24 110-125 (Add "D")
* Codes "S" & "Z" are 120 VAC only. All other codes are
"AD" for NC input or "ZZ" for NO input.
SEE SECTION 10 FOR MATING SOCKETS
PAGE 35
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
INDUSTRIAL PLUG-IN ALARM RELAY 5 AMP, 2 POLE RSX 1800
GENERAL SPECIFICATIONS
CONTACTS
Contact Material:
Silver Cadmium Oxide.
5 AMP, 120Vac/30Vdc Resistive
20 mS Max. @ Nominal Voltage.
Rating:
LEGEND
TIMING
Operate Time:
Release Time:
K1 - Alarm/Silencing Relay.
K2 - Alarm/Silencing Relay.
A - Horn & optional Flasher.
TT - Lamp test (optional).
L1 - Line voltage.
R - Reset (optional for
manual reset only.
S - Horn Silence (acknowledge).
F - Flasher (Optional).
N - Neutral.
Relays are supplied only with the
items and wiring shown within the
rectangles in schematics.
25 Milliseconds max.
20 milliseconds max.
DIELECTRIC STRENGTH
Across open contacts:
Between all mutually
insulated current
carrying parts:
NOTE: For additional alarms,
jumper to like terminals as shown.
500 V rms
1500 V rms
TEMPERATURE
Rated Operation:
-10˚C to +70˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
20 Million Operations no load
500,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Operating Position:
Weight:
Clear polycarbonate.
Any
8.8 oz (250 g) approx.
* OMIT for RESET (RSX1800Z)
MANUAL RESET (RSX1800S)
Manual (Push-button) K1 K2 Flasher
Horn
Reset Sequence.
1- Normal
ON ON OFF OFF
2- Alarm
OFF ON ON
ON
3- Acknowledge
OFF OFF OFF OFF
4- Alarm Contact
Recloses
OFF OFF OFF OFF
5- Reset
ON ON OFF OFF
6- Lamp Test
ON ON OFF OFF
AUTOMATIC RESET (RSX1800S)
Lamp
OFF
Flashing
ON
ON
OFF
ON
Automatic
Reset Sequence.
1- Normal
2- Alarm
3- Acknowledge
4- Alarm Contact
Recloses
5- Lamp Out
RSX1800S
NC Alarm contact
K1
N
1
7
Acknowledge
Flasher
Contact
K2
5
K2 K1 K1 K2
3
L1
6
RS F T
K1
OFF
ON
AUTO or MANUAL RESET
K1
1
3
K1
N
6
SF T
K1
K1
7
1
8
Horn
Acknowledge
Alarm
Lamp
DS
Flasher
Contact
Lamp
Test
N
L1 R
Flasher
Motor
M
K2
K2 9
5
K2 K1 K1 K2
3
6
Horn
4
K2
K2
Alarm
Lamp
DS
K1
2
12
A
K1
No trouble
contact
4
K2
K2
2
Lamp
Test
L1
Flasher
Motor
M
K2
K2 9
5
K2 K1 K1 K2
Flasher
Contact
Alarm
Lamp
DS
A
Reset
7
Horn
N
L1
K1
K2
Acknowledge
12
RSX1800Z
N
8
NC Alarm cont.
9
K1
2
Lamp
Test
Flasher
Motor
M
4
K2
K2
OFF OFF
OFF OFF
RSX1800S
L1
K1
K2
K2
On On
ON ON
External Jumper
8
Reset
ON ON OFF OFF OFF
OFF ON ON ON Flashing
OFF OFF OFF OFF ON
1- Normal
OFF ON OFF OFF OFF
2- Alarm
ON ON ON ON Flashing
3- Acknowledge
ON OFF OFF OFF ON
4- Trouble Contact
Reopens. Auto reset OFF ON OFF OFF OFF
Manual reset ON OFF OFF OFF ON
5- Reset
OFF ON OFF OFF OFF
6- Lamp Test
OFF ON OFF OFF ON
* External Jumper supplied be Customer.
AUTOMATIC RESET
MANUAL RESET
L1
K1 K2 Flasher Horn Lamp
Automatic or Manual K1 K2 Flasher
Horn Lamp
K1
SFT
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
12
A
N
PAGE 36
CLASS
FLASH TRANSFER RELAY SWITCHES TUNGSTEN LOADS
21
CLASS 21
MEETS NEMA STD. TS 2- 1992
APPROVED BY D.O.T FOR:
California Minnesota Georgia
New York Illinois
Texas
Oregon
Colorado
Missouri
PLUG-IN BASE WITH POLARIZING PIN
DPDT CONTACT CONFIGURATION
SWITCHES TUNGSTEN LAMP LOADS
UP TO 20 AMPS
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E43641
OUTLINE DIMENSIONS
DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS)
1.85 Max.
(46.9)
.060
(1.5)
.500
(12.7)
2.84 Max.
(72.2)
Polarizing
Pin
WIRING DIAGRAM
VIEWED FROM PIN END
.250 Typ.
(6.35)
2.12.
(53.9)
2.47 Max.
(62.7)
.437 Typ.
(11.09)
3.90 Max.
(99.2)
.500 Typ.
(12.7)
.600
(15.4)
1.00
(25.4)
7
8
5
6
3
4
v1
2
Rectified Coil
SPECIFICATIONS CLASS 21 RELAY
COIL
Pull-in Voltage:
AC: 70% of Nominal @ 20˚C or less
Dropout Voltage:
Coil Insulation :
10% of Nominal Voltage or more
Class "B" System (130˚C) per UL 1446
TEMPERATURE
Operating:
CONTACTS
Contact Material:
Silver alloy 3/8" dia.
Contact Configuration: DPDT
Contact Rating:
LIFE EXPECTANCY
Electrical:
20Amps, 28VDC (Resistive).
1-1/2 HP, 120VAC (Motor)
2HP, 240VAC (Motor)
20Amps, 120VAC (Tungsten Lamp)
10Amps, 240VAC (Tungsten Lamp)
Dual Marked Part Number
W21ACPX-2 /W21ACPXD-5
DIELECTRIC STRENGTH
Across open contacts
500 V rms
Contact to Coil:
1500 V rms
Contact to Frame:
1500 V rms
Mechanical:
MISCELLANEOUS
Enclosure:
Operating Position:
Weight:
Contact
Configuration
DPDT
-40˚C to +84˚C
200,000 Operations min. at 20 Amps
Tungsten, 120VAC.
5 Million Operations MIN. (No Load)
Clear Polycarbonate
Vertical contacts up or horizontal
7.2 oz.. 204.7 Grams
Coil Measured at 25˚C
Nominal Voltage Nominal Power
120VAC
4.0 VA
Type
* Rectified
* Rectified type coil provides:
1. Chatter Free operation in Brownout conditions down to 85VAC and will not overheat up to 130VAC.
2. Less Power consumption and less Heating.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 37
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
10 AMP, HERMETICALLY SEALED, STEEL CAN RELAY
88HP
CLASS 88HP
8 OR 11 PIN OCTAL BASE
HERMETICALLY SEALED STEEL CAN
Enclosure is filled with dry nitrogen,solder sealed and
then electronically leak checked to prevent contamination
of Internal parts. The case is painted gray to protect
against the elements.
CONTACT RATINGS TABLE
WIRING DIAGRAM
VIEWED FROM PIN END
120 VAC
240 VAC
2 POLE
12 AMP
1/3 HP
8 AMP
1/2 HP
10 AMP
3 POLE
10 AMP
1/3 HP
6 AMP
1.2 HP
10 AMP
POLES
28 VDC
SPECIFICATIONS CLASS 88HP RELAY
DPDT
COIL
Pull-in voltage:
3PDT
Dropout:
Coil resistance
Nominal power:
Max.coil Dissipation:
Duty:
OUTLINE DIMENSIONS
Dimensions are shown in Inch and (Millimeter).
1.53
(38.8)
2.03
(51.5)
CONTACTS
Contact material:
Contact resistance:
3/16" silver cadmium oxide, gold flashed.
50 Milliohms maximum initial resistance at rated current
TIMING
Operate time:
Release time:
25mS or less at nominal voltage.
20mS or less at nominal Voltage.
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Pole to pole
Contacts to frame:
Insulation resistance:
1500 V rms
1000 V rms
1500 V rms
1500 V rms
10,000 megohms min. @ 500 VDC
TEMPERATURE
Operating:
Storage:
-10˚C to +50˚C (AC), -10˚C to +60˚C (DC)
-30˚C to 105˚C
SHOCK RESISTANCE
Operating:
Non operating:
5 G's
20 G's
VIBRATION RESISTANCE
Operating:
Non operating:
5 G's, 10 Hz to 55 Hz
5 G's, 10 Hz to 55 Hz
MISCELLANEOUS
Enclosure:
Terminals
Operating Position:
Weight:.
1.68
(42.8)
CONTACT NO. OF PINS
CONFIGUOCTAL
PART NUMBERS RATION
STYLE
AC OPERATED 50/60Hz Operation.
8 PIN
W88AHPX-24
DPDT
11 PIN
W88AHPX-36
3PDT
80% of nominal voltage or less. For DC coils
85% of nominal voltage or less. For AC coils.
10% of nominal voltage or more.
± 10 % measured @ 25 ˚C
1.5 Watts for DC coils, 3VA for AC coils
DC coils 3.0 Watts max.
Continuous
Hermetically Sealed Steel
Can with octal plug.
8 or 11 pin octal plug-in
Any
5 ozs. 141.7 g approx.
COIL Measured @ 25˚C
CROSS REFERENCE
NOMINAL
NOMINAL
TO
NOMINAL
INPUT
RESISTANCE
POWER
POTTER & BRUMFIELD*
VOLTAGE
(OHMS)
120VAC
120VAC
-
3.0VA
3.0VA
KR11AGE (or GF) 120
KR14AGE (or GF) 120
12 VDC
24 VDC
24 VDC
100
400
400
1.5W
1.5W
1.5W
KR11DGE (or GF) 12
KR11DGE (or GF) 24
KR14DGE (or GF) 24
DC OPERATED
W88HPX-33
W88HPX-34
W88HPX-51
DPDT
DPDT
3PDT
8 PIN
8 PIN
11PIN
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
* GF = GOLD FLASHED
SPDT and other special contact combinations along with other coil voltages up to 240VAC are available. Consult Factory.
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 38
S E C T I O N
2
2
PRINTED CIRCUIT BOARD
RELAYS
1 TO 30 AMPERES
Page 39
Magnecraft
Struthers-Dunn
HI-CURRENT P.C. BOARD RELAYS
276
RELAY SERIES
90
91
Pending
FEATURES
SUBMINIATURE EPOXY SEALED
IMMERSION CLEANABLE
EPOXY SEALED IMMERSION
CLEANABLE.
EPOXY SEALED IMMERSION
CLEANABLE.
STANDARD 0.1 GRID
PATTERN
STANDARD 0.1 GRID PATTERN
P.C. BOARD OR FLANGE
MOUNT STYLES.
SINGLE SIDE STABLE DESIGN
5KV SURGE RESISTANCE
COIL TO FRAME.
CLASS "B" OR "F" INSULATION
SYSTEM
MEETS UL 508 & UL 873 SPACING
SPADE TERMINALS ACCEPT
1/4" Q.C. CONNECT TERMINALS. & 3/16'" COIL Q.C.
TERMINALS.
MEETS 4mm INTERNATIONAL
SPACING COIL TO CONTACT.
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
SPST-NO, SPDT
(SPST-NO)
10A, 250 VAC/30 VDC
(SPDT)
7 A, 250 VAC/30 VDC
SILVER ALLOY
100 MILLIOHMS (INITIAL)
CLASS "F" INSULATION
SYSTEM.
SPST-NO
SPDT
30A, 240 VAC 20 A 240 VAC (NO)
20A, 30 VDC 15 A,240 VAC (NC)
10A, 30 VDC
SPDT
SPST-NO
30A, 240 VAC 20 A 240 VAC (NO)
20A, 30 VDC 15 A,240 VAC (NC)
10A, 30 VDC
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (AC)
WATTS,: (DC)
2000 V rms
1500 V rms
2500 V rms
NOT AVAILABLE
5, 6, 12, & 24VDC
NOT AVAILABLE
5, 12, 24 & 110 VDC
24, 120 & 240 VAC
NOT AVAILABLE
200
MILLIWATTS
MILLIWATTS
930
2 VA
-
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
- 40˚ C to + 70˚ C
- 55˚ C to + 105˚ C
- 55˚ C to + 130˚ C
- 55˚ C to + 85˚ C
- 55˚ C to + 130˚ C
TIMING VALUES
OPERATE:
RELEASE:
10 MILLISECONDS
10 MILLISECONDS
15 MILLISECONDS
10 MILLISECONDS
20 MILLISECONDS
20 MILLISECONDS
LIFE
MECHANICAL:
ELECTRICAL:
20 MILLION OPERATIONS
100,000 OPERATIONS
10 MILLION OPERATIONS
100,000 OPERATIONS
10 MILLION OPERATIONS
100,000 OPERATIONS
DIMENSIONS
H
W
L
H
.394 X .50 X .787
APPROVALS
PAGE NUMBER
C
PAGE 44
W
L
.805 X 1.08 X 1.30
H
W
L
1.10 X 1.08 X 1.27
US
PAGE 45, 46
PAGE 47,48
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 40
Magnecraft
Struthers-Dunn
HI-CURRENT & MICRO MINIATURE P.C. RELAYS
9A
RELAY SERIES
NEW!
FEATURES
92
NEW!
EPOXY SEALED IMMERSION
CLEANABLE WITH TAPE SEAL.
EPOXY SEALED IMMERSION
CLEANABLE WITH TAPE SEAL.
P.C. BOARD OR FLANGE
MOUNT STYLES.
PC BOARD OR FLANGE
MOUNT STYLES.
CLASS "F" INSULATION SYSTEM.
CLASS "F" INSULATION
SYSTEM.
SPADE TERMINALS ACCEPT
INSULATED 1/4" Q.C. CONNECT
TERMINALS. & 3/16'" COIL
Q.C.TERMINALS.
1/4" SPADE TERMINALS
ACCEPT 1/4' Q.C. CONNECTORS.
7
MICRO MINIATURE SIZE
CONFORMS TO FCC PART
68.302, 1500V SURGE
RESISTANCE, FCC 68.304
1000V DIELECTRIC STRENGTH.
EXCELLENT R.F. SWITCHING
CHARACTERISTICS
HIGH SHOCK & VIBRATION
RESISTANCE
PC BOARD MOUNTING
ON 0.1 GRID PATTERN
94V-0 PLASTIC, EPOXY SEALED
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
SPST-NO
SPDT
SPST-NO
DPDT
30A, 240 VAC
20A, 30 VDC
20 A 240 VAC
20A, 28 VDC (NO)
15A,240 VAC
10A, 28 VDC (NC)
30A, 277 VAC
20A, 28 VDC
30A, 277 VAC
20A, 28 VDC (NO)
3A, 277 VAC
3A, 28 VDC (NC)
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
75 MILLIOHMS (INITIAL)
100 MILLIOHMS (INITIAL)
SPDT, DPDT
2 A, 24 VDC
1 A, 100 VAC (DPDT)
2A, 120 VAC (SPDT)
50uA, 50mV MIN.
GOLD CLAD SILVER
PALLADIUM CROSS BAR
50 MILLIOHMS, (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH
2500 V rms
500 V rms
2500 V rms
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (AC)
WATTS,: (DC)
NOT AVAILABLE
5, 12, 24 48 & 110 VDC
24, 120 & 240 VAC
12, 24 48 & 110 VDC
NOT AVAILABLE
5, 12, & 24 VDC
1 WATT
4 VA
1.7 WATTS
330-370 MILLIWATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
- 55˚ C to + 85˚ C
- 55˚ C to + 130˚ C
DC,- 40˚ C to + 85˚C -AC,- +65˚C
- 35˚ C to + 70˚ C
TIMING VALUES
OPERATE:
RELEASE:
15 MILLISECONDS
15 MILLISECONDS
15 MILLISECONDS
10 MILLISECONDS
4.0 MILLISECONDS
5.0 MILLISECONDS
LIFE
MECHANICAL:
ELECTRICAL:
10 MILLION OPERATIONS
100,000 OPERATIONS
5 MILLION OPERATIONS
100,000 OPERATIONS
100 MILLION OPERATIONS
100,000 OPERATIONS
DIMENSIONS
H
W
L
1.10 X 1.08 X 1.27
APPROVALS
C
PAGE NUMBER
PAGE 41
US
PAGE 49, 50
H
W
L
1.10 X 1.36 X 1.27
C
US
PAGE 51, 52
H
W
L
.428 X .410 X .410
C
US
PAGE 53, 54
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
Magnecraft
Struthers-Dunn
MINIATURE P.C. BOARD RELAYS
60
49
178
MINIATURE SIZE
MINIATURE EPOXY SEALED.
DUST COVERED
CONFORMS TO FCC PART
68.302, 1500V SURGE
RESISTANCE, FCC 68.304
1000V DIELECTRIC STRENGTH.
P.C. BOARD MOUNTING.
DISPLACES APPROXIMATELY
1.1 CUBIC INCH.
EXCELLENT R.F. SWITCHING
CHARACTERISTICS
SWITCHES UP TO 12 AMP
LOADS.
CLASS "B" OR "F" INSULATION
SYSTEM
HIGH SHOCK & VIBRATION
RESISTANCE
IMMERSION CLEANABLE.
PC BOARD MOUNTING ON 0.1
GRID PATTERN.
DISPLACES APPROXIMATELY
.43 CUBIC INCH.
SPDT, DPDT
2 A, 24 VDC
1 A, 100 VAC (DPDT)
2A, 120VAC )SPDT)
50uA, 50mV MIN.
GOLD CLAD SILVER
PALLADIUM CROSS BAR
50 MILLIOHMS MAX (INITIAL)
330-370 MILLIWATTS
TV-5 RATINGS AVAILABLE.
SPDT
SPDT
5 AMP @ 125/250VAC, 30VDC
(CLASS 178RE1-)
12 AMP @ 120VAC, 28VDC
10AMP @ 125/250 VAC, 30 VDC
(CLASS 178URE1-)
SILVER CADMIUM OXIDE
100 MILLIOHMS (INITIAL)
500 V rms
NOT AVAILABLE
5, 12, & 24 VDC
VARIETY OF MOUNTING
CONFIGURATIONS.
1500 V rms
NOT AVAILABLE
5, 12, & 24 VDC
400
MILLIWATTS
3 AMPS @ 120 VAC/ 28 VDC
5 & 10 AMP @ 240VAC/28VDC
SILVER, GOLD PLATED,
SILVER CADMIUM OXIDE
100 MILLIOHMS (INITIAL)
1500 V rms
NOT AVAILABLE
3, 5, 6, 12, & 24 VDC
400 MILLIWATTS
- 35˚ C to + 70˚ C
- 40˚ C to +70˚ C (272)
- 55˚ C to + 85˚ C
- 55˚ C to + 130˚ C
4.0
5.0
20 MILLISECONDS
10 MILLISECONDS
10 MILLISECONDS
7 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
50 MILLION OPERATIONS
100,000 OPERATIONS
MILLISECONDS
MILLISECONDS
100 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
.570 X .895 X 1.10
C
US
PAGE 55, 56
H
W
L
.620 X .650 X .890
C
H
W
L
1.14 X .759 X 1.25
US
PAGE 57, 58
PAGE 59 , 60
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 42
Magnecraft
Struthers-Dunn
MINIATURE P.C. BOARD RELAYS
RELAY SERIES
76
1330 & 1335
NEW!
SEE SECTION 10
FOR
MATING SOCKETS
FEATURES
MINIATURE SIZE
EPOXY SEALED IMMERSION
CLEANABLE.
ENCLOSED SEE THRU COVER
WITH P.C. TERMINALS.
MEETS 8 MILLIMETER
SPACING COIL TO CONTACTS
AC OR DC OPERATION
MEETS 4KV DIELECTRIC
WITHSTANDING VOLTAGE.
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
INSULATION
CHARACTERISTICS
DIELECTRIC
DPDT
SPDT
SPDT, DPDT
10 AMPS @
250 VAC/
30 VDC
5 AMP RESISTIVE OR 3 AMP
INDUCTIVE SWITCHING.
UL RATED - 5A, 120VAC, NON
UL RATED - 5A, 30 VDC
3A, 120VAC INDUCTIVE.
1/8 HP, 120 VAC
16AMPS @
240 VAC/
24 VDC
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
100 MILLIOHMS MAX.
(INITIAL)
STRENGTH
4000 V rms
1500 V rms
SPECIAL ORDER
5,6, 12, 24 & 48 VDC
24, 120 VAC
12, 24 VDC
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (AC)
WATTS,: (DC)
520
1.2 VA
1.2 W
MILLIWATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
- 20˚ C to + 70˚ C
- 45˚ C to + 70˚ C
TIMING VALUES
OPERATE:
RELEASE:
15 MILLISECONDS
10 MILLISECONDS
20
20
LIFE
MECHANICAL:
ELECTRICAL:
20 MILLION OPERATIONS
150,000 OPERATIONS
AC, 50 M. DC, 100M OPERATIONS
100,000 OPERATIONS
DIMENSIONS
PAGE NUMBER
PAGE 43
H
H
W
L
.811 X .512 X 1.14
APPROVALS
W
L
.905 X .728 X 1.07
C
PAGE 61, 62
MILLISECONDS
MILLISECONDS
US LIMITED RATINGS
PAGE 63
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE POWER RELAY 10 AMP, P.C. MOUNTABLE
SERIES
276
SERIES 276
ACTUAL SIZE
DTL COMPATIBLE
SINGLE SIDE STABLE DESIGN
5KV SURGE RESISTANCE COIL TO CONTACT
MEETS INTERNATIONAL SPACING -4 mm COIL TO CONTACT
SPECIFICATIONS SERIES 276
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
Nominal Power:
75% of Nominal Voltage or less
10% of nominal voltage or more
110% of nominal voltage.
±10%
200mW Approx.
CONTACTS
Contact Material:
Contact Resistance:
Silver Alloy
100 Milliohms initial @ 6VDC, 1 Amp
TEMPERATURE
Operating::
-40˚C to +70˚C
VIBRATION RESISTANCE
Functional:
10g's 10 to 55Hz, .06" DA
SHOCK RESISTANCE
Functional:
100g's no damage
LIFE
Electrical (Rated Load):
Mechanical ( No Load):
TIMING
Operate Time:
Release Time:
10 mS Max. @ Nominal Voltage.
10 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Contacts to Coil:
Across open contacts:
Surge voltage resistance:
Insulation Resistance:
2000 V rms
1000 V rms
5000 V rms between coil and contacts
500 VDC Exceeds 1000 Megohms min..
MISCELLANEOUS
Operating Position:
Enclosure:
Weight:
100,000 Operations
20 Million Operations
Any
Plastic Cover, Epoxy sealed,
0.2 oz. ( 5.5 grams) approx.
LOW LEVEL LOADS: NOT SUITABLE BELOW
20 WATTS
OUTLINE DIMENSIONS
Dimensions shown are in "Inch" and ( Millimeter)
-
.787 Max.
(20)
CIRCUIT BOARD SPACING
Layout shown is on a 0.100 Grid
BOTTOM VIEW
WIRING DIAGRAM
BOTTOM VIEW
+
SPDT
.051 Dia.
(1.3)
5 Places
.394
Max.
(10)
+
-
0.50
(12.7)
.138
(3.5)
SPST-NO
.015 x .030
(.4 x .8) 3 Places
0.20 Dia.
(0.5) 2 Coil Terminals
Struthers-Dunn
CONTACT LOAD RATINGS
LOAD
CONDITION
SPST-NO
10 AMPS @ 250 VAC
10 AMPS @ 30 VDC
* MAX. SWITCHING POWER: 300 WATTS (DC)
2500 VA (AC)
* MAX. SWITCHING CURRENT: 10 AMPERES
* MAX. SWITCHING VOLTAGE: 125 VDC
380 VAC
1/6 HP @ 120 VAC
MOTOR:
B300
PILOT DUTY:
RESISTIVE LOADS:
SPDT
7 AMPS @ 250 VAC
7 AMPS @ 30 VDC
210 WATTS (DC)
1750 VA (AC)
7 AMPERES
125 VDC
380 VAC
1/10 HP @ 120 VAC
B300
* Voltage current, and power ratings in the table above are
independent maximums and no single value is to be exceeded.
Part Numbers
276AXXH-5D
276AXXH-6D
276AXXH-12D
276AXXH-24D
276XAXH-5D
276XAXH-6D
276XAXH-12D
276XAXH-24D
COIL - Measured at 25˚C
Nominal Nominal Nominal
ResisContact
Input
power
tance
Configuration Voltage
(mW)
(Ohms)
200
5 VDC
125
SPST-NO
200
6 VDC
180
SPST-NO
200
12 VDC
720
SPST-NO
200
24 VDC
2880
SPST-NO
200
5 VDC
125
SPDT
200
6 VDC
180
SPDT
200
12 VDC
720
SPDT
200
24 VDC
2880
SPDT
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
NOTE: Coil polarity must be observed. Relay is polarized with a permanent magnet and will not
be damaged with reverse polarity but will not operate with reverse polarity.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 44
CLASS
30 AMP MINIATURE P.C. BOARD RELAY
90
CLASS 90 RELAY
Class 90 printed circuit board relays provide
an inexpensive means of switching loads up to
30 amps. Designed primarily for the appliance
industry and HVAC markets, they are also well
suited for load management, automotive and
other applications.
SPST-N.O. or SPDT
CLASS "B" OR "F" INSULATION
EPOXY SEALED.
BREAKAWAY NIB
OVER VENT HOLE
(REMOVED AFTER
CLEANING).
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E13224
PC BOARD LAYOUT
(Bottom View )
Pending
A B A
B A
.100
(2.54)
WIRING DIAGRAM
.400
(10.1)
BOTTOM VIEW
.500
(12.7)
.600
(15.2)
FIG. "A"
FIG. "C"
SPST-NO
SPST-NO
NOT USED
ON
CLASS "F"
STYLES
.150
(3.8)
.550
(13.9)
.700
(17.8)
.350
(8.9)
Drill "A" Holes .086 (2.19).
Drill "B" Holes .046 (1.17).
FIG."B"
FIG."D"
SPDT
SPDT
OUTLINE DIMENSIONS
(Actual Size)
Dimensions are in Inchs and (Millimeters)
VENT HOLE NIB
1.08 MAX.
(27.4)
.830 MAX.
(21.08)
.208 Max.
(5.28)
.100
(2.54)
.693
(17.6)
1.30.
(33)
Stand0ff
(qty.5)
.78
(19.8)
.96
(24.3)
PAGE 45
.031 x .062
(.8 x 1.6)
.045 x .045
(1.1 x 1.1)
.150
(3.8)
Pin removed
on Class "F"
styles.
.025 x .025
(.64 x .64)
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
30 AMP MINIATURE P.C. BOARD RELAY
90
SPECIFICATIONS CLASS 90
COIL
Pull-in Voltage:
Dropout Voltage:
Coil Power:
Duty:
Insulation System:
Coil Resistance:
75% of Nominal Voltage or less
10% of Nominal Voltage or more.
2.8 Watts Max.
Continuous
Class "B" (130˚C) or Class "F" (155˚C
±10% measured at 25˚C
CONTACTS
Contact Configuration:
Contact Material:
Contact Resistance:
SPST-N.O., SPDT
Silver Cadmium Oxide.
50 Milliohms Max. Initial Value.
TIMING
Operate Time:
Release Time:
15 mS Max. @ Nominal Voltage.
10mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Across open Contacts
Contacts to Coil:
Insulation Resistance:
Voltage
Load Type
Resistive
Resistive
Ind. & Res.
AC
Motor
DC
Tungsten
Ballast
Resistive
VIBRATION RESISTANCE
Functional:
10 to 55 Hz @ Double Amplitude of 1 mm.
SHOCK RESISTANCE
Functional:
Mechanical:
10 g's for 11 mS, no Contact Opening > 100uS,
100 g's
Electrical (Rated Load): Operations: See Table Below
Mechanical (No Load): 10 million Operations .
MISCELLANEOUS
Operating position:
Enclosure:
Weight:
SILVER CADMIUM OXIDE CONTACT RATINGS
SPST
N.O.
30A @ 240VAC
20A @ 277 VAC
12A @ 277 VAC
1HP @ 125VAC
3/4 HP @ 125VAC
2HP @ 240/250VAC
470VA @ 125/240VAC
30FLA/96LRA, 125VAC
30FLA/80LRA, 240VAC
20FLA/60LRA, 277VAC
27FLA/82.8LRA,125VAC
TV 3 @ 250VAC
6Amp @ 277VAC
20A @ 5-30VDC
-55˚C to +105˚C
-55˚C to +130˚C
Up to 93% @ 40˚C.
650 to 800 mmHg.
LIFE
1000 V rms
1500 V rms
500 Megohms under normal conditions
100 Megohms High Temp, High humidity.
R
TEMPERATURE
Operating:
Storage:
Relative Humidity:
Atmospheric Pressure:
FIGURE "C" & "D" MEETS UL 508 & UL 873 SPACING .
SPDT
N.O.
OPERATIONS
20A @ 240VAC
100,000
20A @ 277 VAC
100,000
12A @ 277 VAC
6,000
30,000
1HP @ 125VAC
100,000
3/4HP @ 125VAC
1,000
2HP @ 240/250VAC
470VA @ 125/240VAC 100,000
30,000
30FLA/96LRA, 125VAC
30,000
30FLA/80LRA, 240VAC
20FLA/60LRA, 277VAC 100,000
27FLA/82.8LRA,125VAC 100,000
25,000
TV 3 @ 250VAC
6Amp @ 277VAC
6,000
20A @ 5-30VDC
100,000
COIL Measured @ 25˚C
PART NUMBERS
NOMINAL
NOMINAL
INPUT
RESISTANCE
VOLTAGE
(Ohms)
Any
94V-0 Flammability rating, Epoxy sealed
Immersion cleanable.
27 Grams approximately.
NOMINAL
POWER
(mW)
SPDT
N.C.
OPERATIONS
100,000
2-10A @ 240VAC, (i&R)
15 AMP @ 240 (i)
100,000
6A @ 277VAC, I&R
6,000
1/4HP @ 125VAC
1/2HP @ 250VAC
275VA @ 125/240VAC
10FLA/33LRA, 125VAC
10FLA/33LRA,240VAC
TV 3 @ 250VAC
3 AMP@ 277VAC
10A @ 5-30VDC
30,000
30,000
30,000
100,000
100,000
6,000
100,000
CROSS REFERENCE
POTTER &
BRUMFIELD
OMRON
SPST-NO , ( 30 AMP ) CLASS "B" INSULATION, FIG "A" WIRING
W90S1D12-5
W90S1D12-12
W90S1D12-24
W90S1D12-110
5VDC
12VDC
24VDC
110VDC
27
155
660
13,450
930
930
870
900
T90S1D12-5
T90S1D12-12
T90S1D12-24
T90S1D12-110
G8P1114PB1USDC5
G8P1114PB1USDC12
G8P1114PB1USDC24
G8P1114PB1USDC110
930
930
870
900
T90S5D12-5
T90S5D12-12
T90S5D12-24
T90S5D12-110
G8P114PB1USDC5
G8P114PB1USDC12
G8P114PB1USDC24
G8P114PB1USDC110
930
930
870
900
T90S1D42-5
T90S1D42-12
T90S1D42-24
T90S1D42-110
G8P1114PCFUSDC5
G8P1114PCFUSDC12
G8P1114PCFUSDC24
G8P1114PCFUSDC110
930
930
870
900
T90S5D42-5
T90S5D42-12
T90S5D42-24
T90S5D42-110
G8P114PCFUSDC5
G8P114PCFUSDC12
G8P114PCFUSDC24
G8P114PCFUSDC110
SPDT, ( 20 AMP ) CLASS "B" INSULATION, FIG "B" WIRING
W90S5D12-5
W90S5D12-12
W90S5D12-24
W90S5D12-110
5VDC
12VDC
24VDC
110VDC
27
155
660
13,450
SPST-NO, ( 30 AMP ) CLASS "F" INSULATION, FIG "C" WIRING
W90S1D42-5
W90S1D42-12
W90S1D42-24
W90S1D42-110
5 VDC
12 VDC
24 VDC
110VDC
27
155
660
13,450
SPDT, ( 20 AMP ) CLASS "F" INSULATION, FIG "D" WIRING
W90S5D42-5
W90S5D42-12
W90S5D42-24
W90S5D42-110
5 VDC
12 VDC
24 VDC
110VDC
27
155
660
13,450
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 46
CLASS
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
91
CLASS 91 RELAY
AC COIL VOLTAGES
30 AMP SWITCHING
CLASS "F" INSULATION
PC or FLANGE MOUNTED.
* REMOVABLE TAPE SEAL
OVER VENT HOLE
(REMOVED AFTER
PC BOARD DRILL PATTERN
CLEANING).
BOTTOM VIEWS
.250 Max.
(6.35)
.300
(7.62)
.250 Max.
(6.35)
.100
(2.54)
A
A
A
.500
(12.7)
B
.150
(3.81)
HOLE "A" = .081 (005) Dia.
HOLE "B" = .043 (003) Dia.
B
.550
(13.9)
.700
(17.8)
*Tape over vent hole is only supplied
on the P.C. terminal versions of this
relay.
OUTLINE DIMENSIONS
(Actual Size)
Dimensions are in "inches" & (Millimeters)
.032 x .62
(.81 x 1.57)
N.C.
A1
FIGURE
"A"
P.C.
MOUNT
N.O.
A1
1.270 Max.
(32.26)
A1
COM.
1.10 Max.
(27.94)
1.080 Max.
(27.43)
.045 x .046
(1.14 x 1.14)
.025 x .025
(.63 x .63)
2 places
.130 ± .020
(3.30 ± .51)
WIRING DIAGRAM
BOTTOM VIEWS
N.C.
A1
N.O.
A1
1.713 ± .010
(43.51 ± .25)
A1
COM.
B1
1.980 Max.
(50.29)
1.27 Max.
(32.26)
FIGURE
"B"
FLANGE
MOUNT
SPDT
SPST-NO
B1
.071Rad. (1.80) For #6 screw ( 2 places)
A1 = .250 x .032 (6.35 x .81) Quick Connect Terminal
B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal
PAGE 47
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
CLASS
91
SPECIFICATIONS CLASS 91
COIL
Pull-in Voltage AC:
Dropout voltage:
Max. coil voltage:
Power consumption:
Duty:
Insulation System:
Coil Resistance
TEMPERATURE
Operating:
Storage:
85% of Nominal Voltage or Less
10% of Nominal voltage or More
120% Max.
2.0VA max. AC Coils
Continuous
Class "F" (155˚C)
±10% measured @ 25˚C
-55˚C to +85˚C
-55˚C to +130˚C
VIBRATION RESISTANCE
Functional:
10 to 55Hz 1.5 mm max. No contact
opening 100
> uS
SHOCK RESISTANCE
Functional:
CONTACT
Contact Configuration:
Contact Material:
Switching voltage:
Contact Resistance:
Minimum Load:
SPST-N.O., SPDT
Silver Cadmium Oxide
277 Vac, 30VDC max.
50 Milliohms @ 100mA, 6VDC Max.
1A, 5VDC, 12VAC
TIMING
Operate Time:
Release Time:
20 mS max
20 mS max.
DIELECTRIC STRENGTH
Between Open Contacts:
Contacts to coil:
Insulation Resistance
1500 V rms
2500V rms
1000 mΩ min. @ 500 VDC
10 g's for 11 mS, No contact Opening
> 100 uS
100 g's
Mechanical:
LIFE
Electrical (Rated Load)
Mechanical (No Load):
100,000 Operations
1 million Operations (AC)
10 million Operations (DC)
MISCELLANEOUS
Operating Position:
Enclosure:
Any
Epoxy sealed immersion cleanable suitable for automatic circuit board
processing. Max. exposure
to temperature is 6 sec.@ 300˚C.
1/4" Q.C. Contacts, 3/16" Q.C. Coil
33 Grams, 1.2 oz approx.
Terminals:
Weight:
CONTACT RATINGS
RATING
RESISTIVE 30A @ 240VAC
20A @ 28VDC
LOAD
1 HP @120VAC
hp
2HP @ 240VAC
Tungsten TV-5, 120VAC
10A, 277VAC
Ballast
LRA/FLA
SPDT
50/60Hz
SPST-NO
50/60Hz
N.O.
80/30 @ 240AC
98/22 @ 120AC
N.O.
N.C.
20A @ 240VAC
20A @ 28 VDC
1 HP @ 125VAC
2HP @ 240VAC
TV-5, 120VAC
10A, 277VAC
50/20 @ 240AC
10A @ 240VAC
10A @ 28VDC
1/4HP @ 120VAC
1/2HP @ 240VAC
TV-3, 120VAC
3A, 277VAC
20/7 @ 240AC
Coil measured @ 25˚ C
PART NUMBERS
SPST-NO
30AMP
P.C. MT.
FIGURE "A"
SPDT
20AMP
P.C. MT.
FIGURE "A"
SPST-NO
30AMPFLANGE MT.
FIGURE "B"
SPDT
20AMP
FLANGE MT.
FIGURE "B"
NOMINAL NOMINAL NOMINAL
RESIS- POWER
INPUT
TANCE
(VA)
VOLTAGE (Ohms)
AC OPERATED COIL
W91S1A22-24 W91S5A22-24 W91S1A32-24 W91S5A32-24 24 VAC
W91S1A22-120 W91S5A22-120 W91S1A32-120 W91S5A32-120 120 VAC
W91S1A22-240 W91S5A22-240 W91S1A32-240 W91S5A32-240 240 VAC
-
2 VA
2 VA
2 VA
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 48
CLASS
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
9A
CLASS 9A RELAY
Recognized Component mark for
Canada and the United States.
30 AMP SWITCHING.
C
US
UL Recognized
CLASS "F" INSULATION.
File No. E43641
PC or FLANGE MOUNTED.
EPOXY SEALED WITH
REMOVABLE TAPE SEAL
OVER VENT HOLE
(REMOVED AFTER
CLEANING).
PC BOARD DRILL PATTERN
!
W
NE
BOTTOM VIEWS
.140 Max.
(3.56)
.300
(7.62)
.250 Max.
(6.35)
.100
(2.54)
A
A
A
.600
.500
(15.24) (12.7)
.150
(3.81)
OUTLINE DIMENSIONS
(Actual Size)
NC
NO
.550
(13.97)
.700
(17.8)
.032 x .62
(.81 x 1.57)
A1
A1
FIGURE
"A"
P.C.
MOUNT
COM
1.270 Max.
(32.26)
B
HOLE "A" = .081 ± .005 Dia.
(2.06 x .13)
HOLE "B" = .043 ± .08 Dia.
(1.09 x .08)
Dimensions are in "inches" & (Millimeters)
A1
B
1.10 Max.
(27.94)
1.080 Max.
(27.43)
.045 x .045
(1.14 x 1.14)
.025 x .025
(.63 x .63)
2 places
.130 ± .020
(3.30 ± .51)
WIRING DIAGRAM
NC
BOTTOM VIEWS
COM
NO
A1
1.713 ± .010
(43.51 ± .25)
B1
B1
B1
B1
A1
A1
1.980 Max.
(50.29)
1.27 Max.
(32.26)
FIGURE
"B"
FLANGE
MOUNT
SPDT
SPST-NO
.071Rad. (1.80) For #6 screw ( 2 places)
A1 = .250 X .032 (6.35 X .81) Quick Connect Terminal
B1 = .187 x .020 (4.78 x .508) Quick Connect Terminal
PAGE 49
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
30 AMP PC or FLANGE MOUNT MINIATURE RELAY
CLASS
9A
SPECIFICATIONS CLASS 9A
COIL
Pull-in Voltage:
Dropout voltage:
Max. coil voltage:
Power consumption:
Duty:
Insulation System:
Coil Resistance
CONTACT
Contact Configuration:
Contact Material:
Switching voltage:
Contact Resistance:
TEMPERATURE
Operating:
Storage:
75% of Nominal Voltage or Less
10% of Nominal voltage or More
120% Max.
2.8 Watts max.
Continuous
Class "F" (155˚C)
±10% Measured @ 25˚C
-55˚C to +85˚C
-55˚C to +130˚C
VIBRATION RESISTANCE
Functional:
SHOCK RESISTANCE
Functional:
10 g's for 11 mS, No contact Opening
> 100 µS
100 g's
SPST-N.O., SPDT
Silver Cadmium Oxide
277 VAC, 28VDC max.
75 Milliohms @ 1 min, rated current
(switched)
1A, 5VDC, 12VAC
LIFE
Electrical (Rated Load)
Mechanical (No Load):
TIMING
Operate Time:
Release Time:
DC:15 mS typ. including bounce
DC:15mS typ. including bounce
MISCELLANEOUS
Operating Position:
Enclosure:
DIELECTRIC STRENGTH
Between Open Contacts:
Contacts to coil:
Insulation Resistance
1500 V rms
2500V rms
1000 mΩ min. @ 500 VDC, 25˚C 50% RH
Minimum Load:
10 to 55Hz 1.65 mm
max. No contact opening 100
> uS
Mechanical:
100,000 Operations
10 million Operations Typical
Any
Epoxy sealed immersion cleanable
suitable for automatic circuit board
processing. Max. exposure soldering
temperature is 4 sec.@ 500˚F.
94V-O Flammability rating.
1/4" Q.C. & safety wells accept insulated
Female Q.C. terminals.
33 Grams, 1.2 oz approx.
Enclosure:
Terminals:
Weight:
CONTACT RATINGS
Meets UL 508, UL 873 and UL 1950 - 1/8" thru air - 1/4" over surface (See Foot notes)
AC Measured @ 50/60Hz
RATING
GENERAL PURPOSE
RESISTIVE
RESISTIVE HEATER ††
MOTOR (HP)
MOTOR
FLA/LRA ‡
TUNGSTEN
BALLAST
PILOT DUTY
LOAD
VOLTAGE
240 VAC
240 VAC
28 VDC
240 VAC
125 VAC
240 VAC
120 VAC
240 VAC
240 VAC
277 VAC
240 VAC
SPDT
SPST
OPERATIONS
N.O.
N.C.
N.O.
N.C.
30A
20A
20A
25A
1 HP
2 HP
22/98A
30/80A
TV-5
10A
470 VA
*15A
†15A
10A
1/4 HP
1/2 HP
12/30A
3A
275 VA
20A
20A
20A
1 HP
2 HP
30/80A
TV-5
10A
470 VA
10A
†15A
10A
1/4 HP
1/2 HP
12/30A
3A
275 VA
100,000
100,000
100,000
100,000
1,000
1,000
30,000
30,000
25,000
6,000
6,000
* 15 Amp general purpose rating on SPST-NC contact valid only under UL 508 column B spacings and UL
873 columns B, C & D spacings. Derate to 10 Amps when used under UL 873 columns E & F spacings
and UL 1950.
† 15 Amp resistive rating on SPST-NC contacts and SPDT contacts (Normally closed side only) valid only
under UL 873 columns E & F spacings. Derate to 10 Amps when used under UL 508 Column B spacings,
under UL 873 columns B, C & D spacings and UL 1950.
†† The resistance heater rating is not a discreet UL heater rating but is a valid UL rating that is derived
from the UL general purpose category in the above table of contact ratings.
‡ FLA = Full load Amps, LRA = Locked rotor Amps.
Coil measured @ 25˚ C
PART NUMBERS
SPST-NO
30AMP
P.C. MT.
FIGURE "A"
SPDT
30AMP
P.C. MT.
FIGURE "A"
DC OPERATED COIL
W9AS1D22-5 W9AS5D22-5
W9ASID22-12 W9AS5D22-12
W9ASID22-24 W9AS5D22-24
W9ASID22-48 W9AS5D22-48
W9ASID22-110 W9AS5D22-110
SPDT
SPST-NO
30AMP
30AMPFLANGE MT. FLANGE MT.
FIGURE "B" FIGURE "B"
W9AS1D52-5
W9ASID52-12
W9ASID52-24
W9ASID52-48
W9ASID52-110
W9AS5D52-5
W9AS5D52-12
W9AS5D52-24
W9AS5D52-48
W9AS5D52-110
NOMINAL NOMINAL NOMINAL
RESIS- POWER
INPUT
TANCE
(Watts)
VOLTAGE (Ohms)
5
12
24
48
110
25
144
576
2,304
12,100
1W
1W
1W
1W
1W
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 50
CLASS
92
30 AMP PC or FLANGE MOUNT 2 POLE RELAY
Recognized Component mark for
Canada and the United States.
CLASS 92 RELAY
!
W
NE
30 AMP SWITCHING.
CLASS "F" INSULATION.
PC or FLANGE MOUNTED.
EPOXY SEALED WITH
* REMOVABLE TAPE SEAL
OVER VENT HOLE
(REMOVED AFTER
CLEANING).
C
US
UL Recognized
File No. E43641
PC BOARD DRILL PATTERN
.162
(4.12)
BOTTOM VIEWS
.630 ± .005
(16.00)
.203 TYP
(5.16)
.309 ± .005
(7.85 ± .13)
.585 ± .005
(14.8 ± .13)
HOLE "B"
OUTLINE DIMENSIONS
HOLE "A"
.185 TYP
(4.70)
Dimensions are in "inches" & (Millimeters)
1.33 Max.
(33.78)
1.618 TYP
(41.10 ± .51)
1.00 ± .010
(25.40)
.309 ± .005
(7.85 ± .13)
2.06 Max.
(52.32)
.586 ± .005
(14.8 ± .13)
FIGURE
"A"
P.C.
MOUNT
.047 TYP.
(1.19)
.250 TYP
(6.35)
1.618 TYP
(41.10 ± .51)
.156
(3.96)
.032 TYP
(0.81)
.630 ± .005
(16.00)
HOLE "A" = .072 x .050 typ.
(1.83)
HOLE "B" = .052 x .050 typ.
(1.32)
1.10 Max.
(27.94)
1.00 ± .010
(25.40)
1.04 Max.
(26.42)
Note: An alternate P.C. Board
layout Utilizes .076 ±.003 diameter
holes on the layout above. Use of
retangular holes is recommended
for improved solderability.
*Tape over vent hole is only supplied
on the P.C. terminal versions of this
relay.
WIRING DIAGRAM
TOP VIEW
6
8
7
.309 ± .005
(7.85 ± .13)
2.06 Max.
(52.32)
2.35 ±.005
(59.7 ±.13)
0
1
.585 ± .005
(14.8 ± .13)
2.70 Max.
(68.58)
FIGURE
"B"
FLANGE
MOUNT
1.36 Max.
(34.54)
.090 Rad
(2.29) For
#8 screws
DPDT
6
8
.250 TYP
(6.35)
1.618 TYP
(41.10 ± .51)
PAGE 51
2
4
3
2
4
0
1
DPST-NO
1.485 Max.
(37.72)
Only necessary terminals
are present on single
throw styles.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
30 AMP PC or FLANGE MOUNT 2 POLE RELAY
92
SPECIFICATIONS CLASS 92
COIL
Pull-in Voltage:
AC: 80% of Nominal Voltage or Less
DC: 75% of Nominal Voltage or Less
10% of Nominal voltage or More
Dropout voltage:
120% Max.
Max. coil voltage:
Max. Operating Frequency: 14 Operations per minute
AC Coil: 4.0VA, DC Coil: 1.7W
Nominal Power:
Continuous
Duty:
Class "F" (155˚C)
Insulation System:
±10% Measured @ 25˚C
Coil Resistance
CONTACT
Contact Configuration:
Contact Material:
Contact Load Ratings:
Contact Resistance:
Minimum Load:
DPDT Standard
Silver Cadmium Oxide
SEE CONTACT LOAD RATINGS CHART
100 Milliohms @ Initial rated
current (switched)
N.O. 500 mA @ 12 VAC/VDC
N.C. 100mA @ 6 VAC/VDC
TIMING
Operate Time:
Release Time:
DC:15 mS typ. 25ms w/ bounce
DC:10mS typ. 25 ms w/ bounce
DIELECTRIC STRENGTH
Between Open Contacts:
Contacts to coil:
Insulation Resistance
1500 V rms
4000V rms
103 meg Ω min. @ 500 VDC, 25˚C 50% RH
TEMPERATURE
Operating:
AC:-40˚C to +65˚C, DC:-40˚C to +85˚C
VIBRATION RESISTANCE
0.065 (1.65 mm) double amplitude-10 thru 55 Hz
Functional:
SHOCK RESISTANCE
Functional:
10 g's for 11 mS, 1/2 sign wave pulse with no
contact opening > 100µs
100 g for 11 ms 1/2 sine wave pulse
Mechanical:
LIFE
Electrical (Rated Load)
Mechanical (No Load):
100,000 Operations
5 million Operations Typical
MISCELLANEOUS
Operating Position:
Enclosure:
Flammability:
Weight:
Any
Epoxy sealed immersion cleanable tape sealed plastic cover.
94V-O Flammability rating.
86 Grams, 3 oz approx.
CONTACT RATINGS
Meets UL 873 and UL 508 spacing - (8mm) thru air, (9.5 mm) over surface.
AC Measured @ 50/60Hz
DPST-N.O. & DPDT
RATING
N.O. CONTACTS
Resistive
Load
N.C. CONTACTS
30A @ 120/277 VAC
20A @ 28 VDC
1 HP @ 120VAC
Hp
2.5 HP @ 240VAC
Tungsten
TV-10, 120VAC
LRA/FLA* 96/22 @ 240VAC, AC Coil
110/25.3 @ 240VAC, DC Coil
Pilot Duty
DPDT
3A @ 277VAC
3A @ 28VDC
3A @ 240 VAC
Note: Vent tape must be removed to achieve listed ratings
* FLA = Full load Amps, LRA = Locked rotor Amps.
.
DPST-NO
30AMP
P.C. MT.
FIGURE "A"
DPDT
30AMP
P.C. MT.
FIGURE "A"
DPST-NO
30AMPFLANGE MT.
FIGURE "B"
CROSS REFERENCE TO OMRON
The relay listed below are crossed
to Magnecraft DPST-NO, 30 Amp,
Flange mount, Figure "B" only.
NOMINAL NOMINAL NOMINAL
See Note below for Variations
RESISPOWER between relays.
INPUT
VOLTAGE TANCE
(Ohms)
OMRON PART NUMBERS
Coil measured @ 25˚ C
PART NUMBERS
DPDT
30AMP
FLANGE MT.
FIGURE "B"
AC OPERATED COIL
W92S7A22-24 W92S11A22-24 24 VAC
W92S7A22-120 W92S11A22-120 120 VAC
W92S7A22-240 W92S11A22-240 240 VAC
DC OPERATED COIL
W92S7D12-12 W92S11D12-12 W92S7D22-12 W92S11D22-12
W92S7D12-24 W92S11D12-24 W92S7D22-24 W92S11D22-24
W92S7D12-48 W92S11D12-48
W92S7D12-110 W92S11D12-110 W92S7D22-110 W92S11D22-110
12 VDC
24 VDC
48 VDC
110 VDC
-
4 VA
4 VA
4 VA
G7L-2A-TUBJ-CB-AC24
G7L-2A-TUBJ-CB-AC120
G7L-2A-TUBJ-CB-AC240
86
350
1,390
7,255
1.7 W
1.7 W
1.7 W
1.7 W
G7L-2A-TUBJ-CB-DC12
G7L-2A-TUBJ-CB-DC24
G7L-2A-TUBJ-CB-DC110
G7L REPLACES G5D22423T
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Note:
The Class W92 Meets Fit and Function when replacing the Omron G7L relay. The case size ( width & lenght ) and mounting
centers on flange are Dimensionally identical except the class 92 is lower in height. The W92 has a higher contact switching
rating then the G7L and requires less coil power for operation. The 1/4" (.250) Q.C. terminals on top of the case of the Class
92 are not located in the same positions as the G7L, but wire hookup will work with existing wiring using Q.C. connectors..
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 52
CLASS
SUBMINIATURE PC MOUNTABLE, EPOXY SEALED
7
CLASS 7
2 AMP SWITCHING
IN THE WORLDS
SMALLEST PACKAGE.
SPDT, DPDT.
ACTUAL SIZE
AVAILABLE WITH SPDT OR DPDT BIFURCATED
GOLD CLAD SILVER-PALLADIUM CROSS BAR
CONTACTS- RATED FOR LOW LEVEL TO 2.0 AMP
SWITCHING.
REQUIRES ONLY .155 SQUARE INCH OF
CIRCUIT BOARD SPACE.
TOTAL VOLUME OF LESS THAN A CUBIC
CENTIMETER.
CONFORMS TO FCC PART 68.302. 1500 V PEAK
SURGE RESISTANCE.
CONFORMS TO FCC PART 68.304. 1000 V
DIELECTRIC WITHSTANDING VOLTAGE..
PC BOARD PATTERN
Drill Plan (TOP VIEW)
The Class 7 Subminiature high
reliability industrial grade relay
has excellent R.F. switching
characteristics.
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E52197
TOP VIEW SHOWN AT
ACTUAL SIZE ON A 0.1 GRID
DIP
CLASS
7
CLASS CLASS
7
7
SIZE COMPARISON OF STANDARD
DIP RELAY TO CLASS 7 RELAYS
The Class 7 relays can be densely packed
together without magnetic interaction from
adjacent relays.
.100
(2.54)
.300
(7.62)
.100
(2.54)
.100
(2.54)
.300
(7.62)
.039 Dia.
(1.0)
0.1 Grid Pattern
OUTLINE DIMENSIONS
Dimensions are in "INCHES" and ( MILLIMETERS )
.410 Max.
PIERCE THRU
(10.4)
VENT HOLE
WIRING DIAGRAM
BOTTOM VIEW
v
^
.410 Max.
(10.4)
SPDT
.428 Max.
(10.9)
v
^
v
^
.100 Typ
(2.54)
PAGE 53
.125
(3.18)
.024 x .012
(0.6 x 0.3 )
DPDT
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SUBMINIATURE PC MOUNTABLE, EPOXY SEALED
COIL
Coil Voltages
Pull-in Voltage:
Dropout:
Max. allowed coil voltage:
Nominal Power:
Max. coil dissipation
Coil Resistance range:
CONTACTS
Contact Configuration:
Contact Rating:
Contact Material:
Contact Resistance:
TIMING
Operate Time:
Release Time:
TEMPERATURE
Operating:
80% of Nominal Voltage or less
10 % of Nominal Voltage or More
120% of nominal voltage, duty cycle: 100%.
327 Milliwatts max., min sensitivity: 200 milliwatts.
0.75 watts.
±10%
SPDT, DPDT
SPDT: 50uA @ 50mV, 2A , 24VDC, 2A, 120VAC,
DPDT: 50uA @ 50mV, 2A, 24VDC, 0.6A,100VAC,
Gold Clad Silver Palladium.
Initial 50 mΩ
100 Milliohms max @ 6VDC 10 Milliamps.
4.0 mS Max. @ Nominal Voltage. Typ.
5.0 mS Max. @ Nominal Voltage. Typ
-35˚C to +70˚C
VIBRATION RESISTANCE
Functional:
15 g's, 10 to 2000 Hz,
No contact opening > 10 uS
Max. contact chatter
Destructive: 50 g'S.
SHOCK RESISTANCE
Functional
50g's 6mS half sine
Mechanical:
Destructive: 150 g's.
LIFE
Mechanical:
Electrical:
100 Million Operations
100,000 Operations- 2 Amp
24VDC,
1.0 AMP 120VAC (Rated Load).
MISCELLANEOUS
Terminal Finish:
Mounting Position:
Enclosure:
Weight:
Terminals are solder Coated
and Epoxy free to provide excellent
solderability. Max. exposure to
soldering temperature is 5 seconds
@ 250˚C.
After cleaning process, pierce a
small hole in cover for venting.
Any
UL, 94V-O Plastic, Epoxy Sealed.
2.7 Grams . (.095 oz.)
OPERATE/RELEASE TIME
4
After cleaning process, pierce
0.40 (1mm) hole in cover for
venting.
OPERATE TIME
3
2
COIL TEMPERATURE RISE
80˚
70˚
1
TEMP. RISE ˚C
MILLISECONDS
7
SPECIFICATIONS CLASS 7
DIELECTRIC STRENGTH
All Mutually Insulated Points: 500 VAC for 1 Minute, 1 Milliamp max.
leakage, or 600VAC for 1 Second, 1
Milliamp leakage.
Meets FCC 68.302 ( 1500V Surge )
Surge Test:
and 68.304 ( 1000V Dielectric ).
500 VDC Exceeds 1000 Megohms.
Insulation Resistance:
RELEASE TIME
0
CLASS
0.7
0.5
0.3
0.6
0.8
0.4
COIL APPLIED POWER (WATTS)
0.9
R.F. PERFORMANCE
Frequency
(MHz)
10
50
100
200
300
400
500
Insertion Loss
(dB)
VSWR
Isolation
(dB)
Common to
N.O. or N.C.
Contacts
Common to
N.O. or N.C.
Contacts
N.O. or N.C.
Contacts to
Coil
0.05
0.10
0.30
0.50
0.60
0.65
0.75
1.03:1
1.04:1
1.05:1
1.06:1
1.07:1
1.08:1
1.10:1
65
50
42
35
31
29
28
Contact
Configuration
W7PCX-1
W7PCX-3
W7PCX-4
SPDT
SPDT
SPDT
W7PCX-5
W7PCX-7
W7PCX-8
DPDT
DPDT
DPDT
50˚
E2
R20
40˚
30˚
20˚
10˚
0
0.1 0.2 0.3 0.4 0.5 0.6 0 . 7 0.8
COIL POWER CONSUMPTION
E2 =
Rt
E2 =
R20
COIL - Measured at 25˚C
Part
Numbers
E2
Rt
60˚
COIL VOLTAGE
COIL RESIST. VALUE AFTER TEMP. WAS RAISED
COIL VOLTAGE
COIL RESIST. VALUE AT 20˚C
CROSS REFERENCE
Nominal
Resistance
(Ohms)
Nominal
Power
(mW)
COMMUNICATIONS
INSTRUMENTS INC / MIDTEX
(CII / MIDTEX)
5 VDC
12 VDC
24 VDC
75
440
1550
330
330
370
MMS105
MMS112
MMS124
5 VDC
12 VDC
24 VDC
75
440
1550
330
330
370
MMS205
MMS212
MMS224
Nominal
Input
Voltage
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 54
CLASS
60
MINIATURE P.C. BOARD RELAY MOUNTABLE ON 0.100 GRID
CLASS 60
BIFURCATED CROSS BAR CONTACTS
LOW LEVEL SWITCHING TO 2 AMPS
SPDT,DPDT CONTACTS
W60HE1S
Recognized Component mark for
Canada and the United States.
W60HE2S
C
US
UL Recognized
File No. E52197
The Class 60 Miniature high
reliability industrial grade
relay has excellent RF
switching characteristics.
OUTLINE DIMENSIONS
DIMENSIONS SHOWN IN "INCHES" AND (MILLIMETERS)
1.10 Max
(27.9)
.570Max
(14.4)
ACTUAL SIZE
FIGURE "A"
TOP VIEW SHOWN AT
ACTUAL SIZE ON A 0.1 GRID
W60HE1S
.010
(0.25)
.175
Max
(4.45)
.025 SQ. PINS
(0.64)
.092
(2.34)
.040 DIA
(1.01) TYP.
W60HE2S
.600 Max
(15.2)
.040 DIA
(1.01) TYP.
1.10Max
(27.9)
CIRCUIT DIAGRAMS
.570Max
(14.4)
FIGURE "B"
BOTTOM VIEW
SPDT
.010
(0.25)
.175 Max
(4.45)
.025 SQ. PINS
(0.64)
.105Max
(2.67)
DPDT
.895 Max
(22.7)
PAGE 55
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE P.C. BOARD RELAY MOUNTABLE ON 0.100 GRID
CLASS
60
SPECIFICATIONS CLASS 60
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Nominal power:
Max. coil dissipation:
Coil Resistance
CONTACTS
Contact Material:
Contact Resistance:
80% of Nominal Voltage or less
10% of nominal voltage or more
120% of nominal voltage, duty cycle 100%
327mW max. min. sensitivity: 200 mW
0.75 Watt
±10% Measured @ 25˚C
Gold Clad Silver Palladium.
Initial 50 Milliohms @ 6VDC, 10mA
100 Milliohms max., After life: 200 mΩ
Low Level: 50uA- 50mV,
SPDT: 2A-24VDC, 2A-120VAC,
DPDT: 2A-24VDC, 0.6A-100VAC,
Contact Rating:
TIMING
Operate Time:
Release Time:
Contact bounce:
4.0 mS Max. @ Nominal Voltage.
10.0 mS Max. @ Nominal Voltage.
2.5 mS operate, 5.0 mS release
DIELECTRIC STRENGTH
All Mutually Insulated Points:
Surge Test:
Insulation Resistance:
TEMPERATURE
Operating:
500 VAC for 1 Minute, 1 Milliamp max.
leakage, or 600VAC for 1 Second,
1 Milliamp leakage.
Meets FCC 68.302 ( 1500V Surge )
and 68.304 ( 1000V Dielectric ).
500 VDC Exceeds 1000 Megohms.
-35˚C to +70˚C
VIBRATION RESISTANCE
Functional:
15g's, 10 to 2000Hz, (No contact opening
greater than 10µS)
SHOCK RESISTANCE
Functional:
Mechanical:
50g's, 6mS Max.
Contact Chatter Destructive 50g's.
LIFE
Electrical (Rated Load):
Mechanical (No Load):
100,000 Operations Rated Load.
100 Million Operations
MISCELLANEOUS
Terminal Finish:
Terminals are solder Coated to provide
excellent solderability.
Max. exposure to soldering temperature is
5 seconds @ 250˚C.
Any
Plastic.
SPDT-5.5 g's, DPDT- 9 g's approx.
Operating Position:
Enclosure:
Weight:
COIL Measured @ 25˚C
PART
NUMBERS
FIGURE "A"
W60HE1S-5DC
W60HE1S-12DC
W60HE1S-24DC
W60HE1S-48DC
FIGURE "B"
W60HE2S-5DC
W60HE2S-12DC
W60HE2S-24DC
W60HE2S-48DC
Contact Nominal
Configu- Input
ration
Voltage
CROSS REFERENCE
Resis- Pull-in
TO
Power
tance
POTTER
&
BRUMFIELD
(Ohms) (mW)
SPDT
SPDT
SPDT
SPDT
5VDC
12VDC
24VDC
48VDC
75
440
1550
5250
200
200
200
200
R50E2Y1-5V
R50E2Y1-12V
R50E2Y1-24V
R50E2Y1-48V
DPDT
DPDT
DPDT
DPDT
5VDC
12VDC
24VDC
48VDC
75
440
1550
5250
200
200
200
200
R50E2Y2-5V
R50E2Y2-12V
R50E2Y2-24V
R50E2Y2-48V
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 56
CLASS
MINIATURE 12 AMP EPOXY SEALED PC BOARD RELAY
178
CLASS 178
5 AMP AND 12 AMP SPDT CONTACTS.
EPOXY SEALED.
CLASS "B" INSULATION SYSTEM.
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E164066
WITHSTANDS THE VAPOR AND SPRAY
CLEANING OF MOST FLUXING SYSTEMS.
TERMINALS ARE SOLDER COATED TO
PROVIDE EXCELLENT SOLDERABILITY.
ACTUAL SIZE
UL CONTACT LOAD RATINGS
5 AMP RELAY STYLE
OPERATIONS
LOAD
100,000
5A @125V
AC
100,000
5A @250V
HP
25,000
1/4 @ 120V
25,000 N.C.
1/4 @ 120V
25,000
120V
TV-3
TV-5
125VA @ 120V 25,000
VA
DC
100,000
5A @ 30V
DC
MOTOR 5A,120VAC,pf=0.5 100,000
LOAD
12 AMP RELAY STYLE
OPERATIONS
LOAD
6,000
12A @ 120V
100,000
10A @ 125V
100,000
10A @ 250V
10A, 1/4 @ 120V 100,000 N.O.
10A, 1/4 @ 250V 25,000
10A, 1/4 @ 120V 90,000 N.C.
25,000
125V
6,000
12A @ 28V
100,000 N.C*
10A @ 30V
-
PC BOARD LAYOUT
( BOTTOM VIEW )
.090
(2.29)
.100
(2.54)
.472
(12.0
.236
(6.0)
.079
(2.0)
.480
(12.2)
.044 Dia.
(1.1) (5 Holes)
*N.0. CONTACT 25,000 @ 30 VDC
OUTLINE DIMENSIONS
Dimensions are in "INCH" and ( MILLIMETERS )
.650 Max
(16.5)
WIRING DIAGRAM
( BOTTOM VIEW )
PIERCE THRU
VENT HOLE
2
3
v
.620Max.
(15.7)
1
^
5
.012
(.30)
4
SPDT
.012
(.30)
.039
(.99)
PAGE 57
.039
(.99)
.890 Max
(22.5)
.140 Typical
(3.6)
.016
(.40)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, Document 100
CLASS
MINIATURE 12 AMP EPOXY SEALED PC BOARD RELAY
178
SPECIFICATIONS CLASS 178
COIL
Pull-in Voltage:
Dropout Voltage:
Maximum Voltage:
Insulation system:
Coil Resistance:
Duty:
75% of Nominal Voltage or less
10% of nominal Voltage or more.
110% of nominal voltage
Class "B" (130˚C per UL std. 1446)
±10% @ 25˚C
Continuous
CONTACTS
Contact Configuration:
Contact Material:
Contact Resistance:
Minimum Load:
SPDT
Silver Cadmium Oxide
100 Milliohms @ 5VDC & 1 Amp Max.
100mA @ 12VDC
TIMING
Operate Time:
Release Time:
Bounce Time (typical):
20 mS Max. @ Nominal Voltage.
10mS Max. @ Nominal Voltage.
Operate: 1ms, typ., Release: 4 ms, typ.
DIELECTRIC STRENGTH
Contacts to Coil:
Across open Contacts:
Insulation Resistance:
1500 VAC for 1 Minute or 1800 VAC 1 Sec
750 VAC for 1 Minute or 800 VAC 1 Sec .
100 Megohms M in. @ 500 VDC
TEMPERATURE
Operating:
-40˚C to +70˚C
VIBRATION RESISTANCE
Functional:
10 to 55Hz Dual Amplitude -1.5 mm
SHOCK RESISTANCE
Functional:
10g's for 11mS (No Contact Opening >100 uS
LIFE EXPECTANCY
Electrical (Rated Load):
Mechanical (No Load):
100,000 Operations
10 Million Operations
MISCELLANEOUS
Terminal Finish:
P.C. Terminals are solder Coated and
Epoxy free to provide excellent solderability.
Max. exposure to soldering temperature
is 6 seconds @ 300˚C.
Any
Plastic, Epoxy sealed, suitable for
Automatic Circuit Board Processing.
After cleaning process, pierce a
small hole in cover for venting.
0.42 oz. (12) grams approximately.
Operating Position:
Enclosure:
Weight:
PART NUMBERS
CONTACT
RATING
COIL Measured @ 25˚C
NOMINAL
NOMINAL
NOMINAL
INPUT
POWER
RESISTANCE
VOLTAGE
(mW)
(OHMS)
CROSS REFERENCE TO
W178RE1-5DC
W178RE1-12DC
W178RE1-24DC
5 AMPS
5 AMPS
5 AMPS
5VDC
12VDC
24VDC
70
400
1600
400
400
400
POTTER &
BRUMFIELD
T70L5D131-5VDC
T70L5D131-12VDC
T70L5D131-24VDC
W178URE1-5DC
W178URE1-12DC
W178URE1-24DC
12 AMPS
12 AMPS
12 AMPS
5VDC
12VDC
24VDC
70
400
1600
400
400
400
T70L5D164-5VDC
T70L5D164-12VDC
T70L5D164-24VDC
IDEC
OMRON
G5L-114P-PS-DC5
G5L-114P-PS-DC12
G5L-114P-PS-DC24
RCN1V-5G-DC5V
RCN1V-5G-DC12V
RCN1V-5G-DC24V
RCN1V-10G-DC5V G5LE-114P-PS-DC5
RCN1V-10G-DC12V G5LE-114P-PS-DC12
RCN1V-10G-DC24V G5LE-114P-PS-DC24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, Document 100
PAGE 58
CLASS
MINIATURE ENCLOSED PC BOARD RELAY - 3 TO 10 AMP
49
CLASS 49 RELAY
Only 1.1 cubic inches.
Variety of mounting configurations.
Printed circuit terminals.
Tapped mounting holes (49R1C4).
TV 5 rating available.
Standard pilot duty 240 VAC.
Magnetic motor controller rating
1/3 Hp at 120VAC.
LOW LEVEL TO 10 AMPS.
PRINTED CIRCUIT OR
BRACKET MOUNTING.
UL Recognized
File No. E52197
49RE1C2-
49R1C4-
OUTLINE DIMENSIONS
(Actual Size)
ALL DIMENSIONS ARE IN INCHES AND MILLIMETERS
Recommended P.C. board holes .067 dia.(1.7)
ALL TERMINALS ARE .056 X .025 (1.42 X 0.64)
49RE1C1-
STYLE RE1C1
STYLE RE1C2
.759 Max.
(19.3)
.759 Max.
(19.3)
1.25 Max.
(31.7)
1.25 Max.
(31.7)
1.14 Max.
(29.1)
1.14 Max.
(29.1)
.186 typ.
(4.72)
.210
(5.3)
.593
(15.0)
.310
(7.8)
.453
(11.5)
.097
(2.5)
.210
(5.3)
.310
(7.8)
.313
(7.9)
.150
(3.8)
.843
(21.4)
.379
(9.63
.546
(13.8
.594
(15.0)
1.015
(25.7)
.915
(23.2)
.687
(17.4)
STYLE R1C4
1.225
(31.1)
.562
(14.2)
.328
(8.3)
WIRING DIAGRAMS
(BOTTOM VIEW)
STYLE RE1C1
R1C4
1.34 Max.
(34.1)
.210
(5.3)
.131
(.33)
STYLE RE1C2
1.14 Max.
(29.1)
.310
(7.8)
4-40 Tapped holes
(2 Req.)
.313
(7.9)
.843
(21.4)
.150
(3.8)
SPDT
SPDT
.759Max.
(19.3)
PAGE 59
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
MINIATURE ENCLOSED PC BOARD RELAY - 3 TO 10 AMP
CLASS
49
SPECIFICATIONS CLASS 49
COIL
Pull-in Voltage:
VG, VW adj. (DC) = 75% ,
VF, VG adj. (AC) = 80%,of nominal
coil voltage or less.
10% of actual pull-in or more
120% Max.
Continuous
±10%
Dropout voltage:
Max. coil voltage
Duty:
Resistance:
CONTACTS
Contact Configuration:
Contact Material:
Contact Resistance:
Contact Rating:
Pilot Duty:
TIMING
Operate:
Release Time:
SPDT
Silver Cad Oxide (5, 10 Amp), 3 Amp (Silver, Gold
Plated).
100 Milliohms Max. initial Value @ 6 Vdc, 1 Amp
5 and 10 Amp @ 120/240 AC, 3 Amp @ 120 VAC,
28 VDC resistive. Motor load: 1/3 Hp @120VAC,
10 Amp only.
TV 3 SPST-NO, SPST-NC, SPDT
TV 5 SPST-NO, (10 Amp only).
SPST-NO, SPST-NC, SPDT
B300
10 mS typical (25 mS max.)
7mS typical (10 mS max.)
PART NUMBERS
PRINTED CIRCUIT BOARD MOUNTING
SPDT, 3 AMP STYLE RE1C1
W49RE1C1VG-3DC-SIL
W49RE1C1VG-5DC-SIL
W49RE1C1VG-12DC-SIL
W49RE1C2VF-6DC-SIL
W49RE1C2VF-12DC-SIL
W49RE1C2VF-24DC-SIL
SPDT, 5 AMP STYLE RE1C1 AND RE1C2
W49RE1C1VG-5DC-SCO
W49RE1C1VG-12DC-SCO
W49RE1C1VG-24DC-SCO
W49RE1C2VF-6DC-SCO
W49RE1C2VF-12DC-SCO
W49RE1C2VF-24DC-SCO
SPDT, 10 AMP STYLE RE1C1
W49RE1C1VW-5DC-SCO
W49RE1C1VW-12DC-SCO
W49RE1C1VW-24DC-SCO
SOLDER TERMINALS, BRACKET MOUNTING
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Coil to frame:
Insulation Resistance:
1,500 V rms
500 V rms
1,500 V rms
1000 mΩ min. @ 500 VDC
TEMPERATURE
Operating:
Storage:
-55˚C to +85˚C
-55˚C to +130˚C
VIBRATION RESISTANCE
Functional:
10 to 55 Hz @ 1.65mm Displacement
SHOCK RESISTANCE
Functional:
Mechanical:
10 g's
100 g's
LIFE
Electrical (Rated Load):
Mechanical No Load):
100,000 Operations. .
50,000, 000 Operations.
MISCELLANEOUS
Soldering temperature:
Operating position:
Enclosure:
Weight:
270˚C (518˚F) max. for 5 seconds max..
Any.
Dust cover.
42 Grams, 1.5 oz approximately.
CROSS REFERENCE
COIL Measured @ 25˚C
Nominal
Input
Voltage
Nominal
Resistance
(Ohms)
Pull-in
Power
(mW)
3 VDC
5/6 VDC
12 VDC
6 VDC
12 VDC
24 VDC
90
235
1350
410
1640
6560
60
60
60
56
56
56
5/6 VDC
12 VDC
24 VDC
6 VDC
12 VDC
24 VDC
235
1350
5400
410
1640
6560
60
60
60
56
56
56
5/6 VDC
12 VDC
24 VDC
100
600
2400
135
135
135
5/6 VDC
12 VDC
235
1350
60
60
5/6 VDC
24 VDC
100
2400
135
135
GUARDIAN
CORNELL
DUBILIER
653-3K
653-6K
653-12K
1345-1C-5DC
1345-1C-12DC
1345-1C-24DC
603-6B
603-12B
603-24B
613-6B
613-12B
613-24B
SPDT, 5 AMP- STYLE R1C4
W49R1C4VG-5DC-SCO
W49R1C4VG-12DC-SCO
SPDT,10 AMP
W49R1C4VW-5DC-SCO
W49R1C4VW-24DC-SCO
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 60
CLASS
MINIATURE EPOXY SEALED PC BOARD POWER RELAY
76
CLASS 76
5, 10 and 16 AMP. CONTACT RATINGS
EPOXY SEALED, IMMERSION CLEANABLE
MEETS 8mm SPACING 5KV DIELECTRIC
UL Recognized
File No. E13224
CONTACT LOAD RATINGS
FIGURE "B"
FIGURE "A"
FIGURE "C"
DPDT (5 AMP)
5AMP @ 250VAC RES.
5AMP @ 30VDC
1/4HP @ 250VAC
SPDT (10AMP)
10AMP @ 250VAC RES.
10AMP @ 30VDC
1/3HP @ 250VAC
SPDT (16AMP)
16AMP @ 240VAC RES.
16AMP @ 24VDC
1/2HP @ 250VAC
OUTLINE DIMENSIONS
(Actual Size)
All Dimensions are in inches and (millimeters)
.512 Max.
(13.0)
1.142 Max.
(29.0)
PIERCE THRU
VENT HOLE
.811Max.
(20.6)
.138
(3.5)Max.
WIRING DIAGRAM
(BOTTOM VIEW)
FIGURE "A"
FIGURE "B"
FOOT PRINT FOR
70-475 SOCKET
FIGURE "C"
FOOT PRINT FOR
70-475 SOCKET
FOOT PRINT FOR
70-478 SOCKET
DRILLING PLAN
(BOTTOM VIEW)
.059
(1.5)
.400
(10.1)
.400
(10.1)
.300
(7.62)
.795
(20.19)
FIGURE "A"
.039 Dia.
(1.0)
.059
(1.5)
.059
(1.5)
.795
(20.19)
.300
(7.62)
.795
(20.19)
FIGURE "B"
.039 Dia.
(1.0)
.300
(7.62)
.28
(7.11)
FIGURE "C"
.039 Dia.
(1.0)
SEE SECTION 10
FOR
MATING SOCKETS
PAGE 61
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
MINIATURE EPOXY SEALED PC BOARD POWER RELAY
76
SPECIFICATIONS CLASS 76
COIL
Pull-in Voltage:
Dropout Voltage:
Nominal Power:
Coil Resistance
DC-75% of Nominal Voltage or less
5% of Nominal Voltage or More
600 mW(1 pole) 800 mw (2 pole )Approx..
±10% Measured @ 20˚C
CONTACTS
Contact Material:
Contact Resistance:
Max.cycle rate:
Minimum Switching Load:
TIMING
Operate Time:
Release Time:
Bounce Time: (Mean Value)
DIELECTRIC STRENGTH
Contacts to Coil:
Across Open Contacts:
Creepage & Clearance
Insulation Resistance:
Silver Cadmium Oxide
100 Milliohms Max.
30 Operations per Minute @ rated Load.
10 VDC @ 10 mA
15 mS Max. @ Nominal Voltage.
10 mS Max. @ Nominal Voltage.
1.2 mS Approx.
TEMPERATURE
Operating:
Humidity:
-30˚C to +70˚C
45 - 85% RH
VIBRATION RESISTANCE
Functional:
10 to 55 Hz Dual Amplitude 1.5mm
SHOCK RESISTANCE
Functional:
Mechanical:
10 g's Min
100 g Min.
LIFE
Electrical (Rated Load):
Mechanical (No Load):
100,000 Operations min.
10,000,000 Operations min.
MISCELLANEOUS
Operating position:
Enclosure:
5000 V rms, for 1 Minute
1000 V rms, for 1 Minute
8 Millimeters Min. Coil & Contacts
500VDC Exceeds 100 Megohms
Any
Epoxy sealed for protection during
automatic wave soldering & cleaning
process. After cleaning process, pierce
a small hole in cover for venting.
13 Grams approx.
Weight:
FIG.
COIL Measured @ 20˚C
NOMINAL Nominal CONTACT CONTACT
Resistance CONFIGUINPUT
RATING
(Ohms)
RATION
VOLTAGE
W76EURCPCX-14
W76EURCPCX-15
W76EURCPCX-16
W76EURCPCX-17
W76EURCPCX-18
"C"
"C"
"C"
"C"
"C"
5 VDC
6 VDC
12 VDC
24 VDC
48 VDC
47
68
275
1,100
4,170
SPDT
SPDT
SPDT
SPDT
SPDT
10 AMP
10 AMP
10 AMP
10 AMP
10 AMP
RKS-5DG-05
RKS-5DG-06
RKS-5DG-12
RKS-5DG-24
RKS-5DG-48
G2R-14-DC5
G2R-14-DC6
G2R-14-DC12
G2R-14-DC24
G2R-14-DC48
JW1FEN-DC5V
JW1FEN-DC6V
JW1FEN-DC12V
JW1FEN-DC24V
JW1FEN-DC48V
W76EURCPCX-61
W76EURCPCX-62
W76EURCPCX-63
W76EURCPCX-64
"A"
"A"
"A"
"A"
5 VDC
6 VDC
12 VDC
24 VDC
47
68
275
1,100
DPDT
DPDT
DPDT
DPDT
5 AMP
5 AMP
5 AMP
5 AMP
RKS-11DG-05
RKS-11DG-06
RKS-11DG-12
RKS-11DG-24
G2R-24-DC5
G2R-24-DC6
G2R-24-DC12
G2R-24-DC24
JW2EN-DC5V
JW2EN-DC6V
JW2EN-DC12V
JW2EN-DC24V
W76EURCPCX-146
W76EURCPCX-147
W76EURCPCX-148
W76EURCPCX-149
W76EURCPCX-150
"B"
"B"
"B"
"B"
"B"
5 VDC
6 VDC
12 VDC
24 VDC
48 VDC
47
68
275
1,100
4,170
SPDT
SPDT
SPDT
SPDT
SPDT
16 AMP
16 AMP
16 AMP
16 AMP
16 AMP
RKS-5DW-05
RKS-5DW-06
RKS-5DW-12
RKS-5DW-24
RKS-5DW-48
G2R-1-E-DC5
G2R-1-E-DC6
G2R-1-E-DC12
G2R-1-E-DC24
G2R-1-E-DC48
PART NUMBERS
CROSS REFERENCE
POTTER &
BRUMFIELD
OMRON
AROMAT
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 62
CLASS
ENCLOSED MINIATURE 2 POLE RELAY
1330 & 1335
SPACE SAVING DPDT, P.C. BOARD RELAY
AC OR DC OPERATED COIL.
RATED: 5 AMPS RESISTIVE, 3 AMPS INDUCTIVE
!
W
NE
Recognized Component mark for
Canadian and the United States.
C
US
PENDING
UL Recognized
File No. E52197
SPECIFICATIONS CLASS 1330 & 1335
MANUFACTURED UNDER
QUALITY SYSTEM
COIL
Pull-in Voltage:
Dropout:
Max. Voltage:
Coil Resistance:
Duty:
75% of Nominal Voltage or less for AC or DC Coils
DC -10% min.or more.
110%
±10% @ 25˚C
Continuous
CONTACTS
Contact Configurations:
Contact Material:
Contact Resistance:
DPDT
Silver Cadmium Oxide, .93 Dia. (2.36).
100 Milliohms Max.
Contact Rating:
UL RATED - 5 Amperers @ 120 VAC resistive
NOT UL RATED - 30 VDC resistive, 3 Amperes Inductive, 1/8 Hp @ 120 VAC.
ISO 9002 & QS 9000
TIMING
Operate Time:
Release Time:
20mS Max. AC, 15 mS Max. DC @ Nominal Voltage, 25˚C.
20mS Max. AC, 15 mS Max. DC @ Nominal Voltage, 25˚C.
DIELECTRIC STRENGTH
Coil to Frame:
Across Open Contacts:
Contact to Frame:
Insulation Resistance:
1500 V rms
500 V rms
1500 V rms
1500 Megohms Min.
TEMPERATURE
Ambient Temperature:
-45˚C to + 70˚C @ Rated Operation.
LIFE EXPECTANCY
Mechanical
AC operated Device in excess of 50 million operations
DC operated devices, in excess of 100 million operations.
100,000 Operations Min. (at rated Resistive load).
Electrical (rated Load):
MISCELLANEOUS
Operating Position:
Insulating Material:
Enclosure:
Weight:
1.075 Max.
(27.3)
.200
Max.
.728 Max.
(18.5)
1
2
3
4
5
6
7
8
9
10
.020 Max.
(.5) Ref.
Any.
Molded parts are diallyl phthalate for higher arc resistance.
Clear heat resistant Polycarbonate Dust Cover.
Approximately 3/4 oz.
P.C. BOARD LAYOUT
.728 Ref
(18.5)
.350
(8.9)
.189
(4.8)
.905 Max.
(23)
.157
(4)
CIRCUIT DIAGRAM
.123
(3.1)
11
.052 Typ.
(1.31)
.905 Ref
(23)
.067 Dia.
(1.7)
8 PL
PART NUMBERS
Nominal
Input
Voltage
AC OPERATED COILS
W1330P-2C-24A 24 VAC
W1330P-2C-120A 120 VAC
DC OPERATED COILS
W1335P-2C-12D 12 VDC
W1335P-2C-24D 24 VDC
.354
.197(5) (9) .551
(14)
.197(5)
.231 Ref
(5.9)
Coil Measured at 25˚C
CROSS REFERENCE
Nominal
Nominal
TO
Resistance
Power
GUARDIAN
(Ohms)
245 Ω
5400 Ω
1.2 VA
1.2 VA
1330P-2C-24A
1330P-2C-120A
125 Ω
500 Ω
1.2 W
1.2 W
1335P-2C-12D
1335P-2C-24D
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 63
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
S E C T I O N
3
3
REED RELAYS
FOR
PRINTED CIRCUIT BOARD
APPLICATIONS
4 VA TO 100 VA.
COAXIAL RELAYS
FOR R.F. SWITCHING.
Page 64
Magnecraft
Struthers-Dunn
PRINTED CIRCUIT BOARD REED RELAYS
"DIP"
"SIP"
RELAY SERIES
131 MERCURY
101
NEW!
DPDT DIP
SPDT
UP
UP
DPDT
EPOXY MOLDED
CONSTRUCTION.
FEATURES
STANDARD 0.1 GRID
SPACING.
AVAILABLE WITH OR
WITHOUT SUPPRESSION
DIODE ACROSS COIL..
.
SOCKET AVAILABLE
SEE SECTION 10
SPDT - EPOXY MOLDED
CONSTRUCTION. DPDT ENCAPSULATED CONSTRUCTION.
ENCAPSULATED
CONSTRUCTION OR EPOXY
MOLDED WITH SIDE
TERMINALS
STANDARD 0.1 GRID
SPACING.
STANDARD 0.1 GRID OR
OPTIONAL 0.15 SPACING.
AVAILABLE WITH SUPPRESSION DIODE ACROSS COIL.
CLASS 107 PROVIDES
4 HOOK- UP PINS TO COIL..
NON LATCHING SINGLE
COIL OR SINGLE & DUAL
COIL MAGNETIC LATCHING.
ELECTROSTATIC SHIELD
OPTIONAL.
ELECTROSTATIC SHIELD
OPTIONAL.
ENCAPSULATED
CONSTRUCTION.
STANDARD 0.1 GRID OR
OPTIONAL 0.15 SPACING.
POSITION SENSITIVE
VERTICAL MOUNTING.
EXCELLENT FOR LOW
LEVEL SWITCHING.
ELECTROSTATIC SHIELD
OPTIONAL.
CONTACT CONFIGURATION:
SPST-NO, SPST-NC
SPST-NO, or NC, SPDT, DPDT
1 to 3PST-NO,
SPST-NO, DPST-N0
MAXIMUM CONTACT RATING:
MAX. SWITCHING
0.5 AMPS or 200 VDC
@ 10 VA
MAX. SWITCHING
0.5 AMPS or 100 VDC
@ 4VA -10VA
MAX. SWITCHING
0.5 AMPS or 200 VDC
@ 10 VA
MAX. SWITCHING
2.0 AMPS or 500 VDC
@ 50 VA
MAX.CARRY LOAD 1.5 AMPS MAX.CARRY LOAD 1.5 AMPS MAX.CARRY LOAD 2.0 AMPS MAX.CARRY LOAD 3.0 AMPS
CONTACT MATERIAL:
RHODIUM
RHODIUM
RHODIUM
100 MILLIOHMS (INITIAL)
100 MILLIOHMS (INITIAL)
100 MILLIOHMS (INITIAL)
1500 V rms
1000 V rms
500 VDC
DC - VOLTAGE RANGE:
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
NOMINAL POWER:
270 mW Max.
650 mW Max.
380 mW Max.
625 mW Max.
CONTACT RESISTANCE:
MERCURY (Hg)
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH:
1000 V rms
COIL DATA
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
TIMING VALUES
MAX. OPERATE:
MAX. RELEASE:
- 40˚ C to + 85˚ C
1 MILLISECONDS
1 MILLISECONDS
LIFE
MECHANICAL:
ELECTRICAL:
100 MILLION OPERATIONS
50 MILLION OPERATIONS
H
DIMENSIONS:
W
L
.290 X .280 X .750
MOUNTING POSITION:
APPLICATION DATA:
PAGE NUMBER:
PAGE 65
ANY
PAGE 68, 69
PAGE 70
- 40˚ C to + 85˚ C
1 MILLISECONDS
1 MILLISECONDS
100 MILLION OPERATIONS
50 MILLION OPERATIONS
H
W
L
.275 X .300 X .750
.338 X .393 X .750 (DPDT)
ANY
PAGE 71 thru 75
- 37˚ C to + 85˚ C
- 40˚ C to + 85˚ C
2 MILLISECONDS
2 MILLISECONDS
1 MILLISECONDS
1 MILLISECONDS
100 MILLION OPERATIONS
50 MILLION OPERATIONS
H
W
L
.355 X .400 to .900 X 1.15
ANY
100 MILLION OPERATIONS
40 MILLION OPERATIONS
H
W
L
.355 X PG.39 X 1.15
VERTICAL ± 15˚
MINIATURE REED SPECIFICATIONS:
PAGE 77
PAGE 76
PAGE 78
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
MINIATURE REED RELAYS
104
134 MERCURY
193
MRR & RR
MR-Y
UP
DUST COVER STANDARD.
DUST COVER STANDARD.
ENCAPSULATED CONSTRUC- ENCAPSULATED CONTION OPTIONAL
STRUCTION OPTIONAL
DUST COVER STANDARD.
ENCAPSULATED CONSTRUCTION OPTIONAL
STANDARD 0.1 GRID OR
OPTIONAL 0.15 GRID
SPACING AVAILABLE.
STANDARD 0.1 GRID
OR OPTIONAL 0.15
SPACING AVAILABLE.
STANDARD 0.1 GRID OR
OPTIONAL 0.15 GRID
SPACING.
POSITION SENSITIVE.
VERTICAL MOUNTED.
UP TO 4PDT OR 6PST
CONTACT ARRANGEMENTS.
EPOXY MOLDED AXIAL
LEAD REED RELAY
EPOXY MOLDED.
STANDARD 0.1 GRID OR
OPTIONAL 0.15 GRID
SPACING AVAILABLE.
EXTERNAL MAGNETIC
SHIELDING FIXED TO
BODY.
MAGNETIC SHIELDING.
SOLID LEADS
END TERMINALS.
TTL COMPATIBLE.
SPDT, DPDT
SPDT, DPDT
1 to 4PDT, 1 to 6PST
1 & 2PST-NO or
NC SPDT, DPDT
1 to 12PST-NO 0r NC
MAX SWITCHING
0.25 AMPS or 100VDC
@ 4 VA
MAX SWITCHING
1.0 AMPS or 500VDC
@ 50 VA
MAX SWITCHING
0.5 AMPS or 200VDC
@ 10 VA
MAX SWITCHING
0.5 AMPS or 200VDC
@ 10 VA
MAX SWITCHING
0.5 AMP or 200VDC
@ 10 VA
MAX.CARRY LOAD 0.5 AMP
MAX.CARRY LOAD 2.0 AMP. MAX.CARRY LOAD 2.0 AMP MAX.CARRY LOAD 1.5 AMP MAX.CARRY LOAD 1.5 AMPS
RHODIUM
MERCURY
RHODIUM
RHODIUM
RHODIUM
200 MILLIOHMS (INITIAL)
100 MILLIOHMS (INITIAL)
200 MILLIOHMS (INITIAL)
200 MILLIOHMS (INITIAL)
200 MILLIOHMS (INITIAL)
500 V rms
1000 V rms
500 V rms
500 V rms
500 V rms
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
5, 12, 24 VDC
6 to 48 VDC
626 mW Max.
620 mW Max.
1030 mW Max.
450 mW Max.
400 mW Max.
-40˚C to + 85 ˚C
-37 ˚C to + 85 ˚C
-40 ˚C to + 85 ˚C
-40˚C to + 85 ˚C
-40 ˚C to + 85 ˚C
1 MILLISECONDS
1 MILLISECONDS
2 MILLISECONDS
3 MILLISECONDS
1 MILLISECONDS
1 MILLISECONDS
5 MILLISECONDS
5 MILLISECONDS
100 MILLION OPERATIONS
50 MILLION OPERATIONS
H
W
L
.355 X .5 to .7 X 1.15
1 MILLISECONDS
1.5 MILLISECONDS
100 MILLION OPERATIONS
40 MILLION OPERATIONS
H
W
L
355 X .5 to .5 X 1.15
100 MILLION OPERATIONS 100 MILLION OPERATIONS 200 MILLION OPERATIONS
50 MILLION OPERATIONS 50 MILLION OPERATIONS 10 MILLION OPERATIONS
H
W
L
.355 X .4 to .9 X 1.15
ANY
VERTICAL ± 15˚
ANY
PAGE 79
PAGE 80
PAGE 81, 82
L
DIAMETER
.312 X 0.4 X .950
.655 X 1.875
ANY
ANY
H
W
PAGE 83, 84
PAGE 85, 86
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 66
Magnecraft
Struthers-Dunn
P.C. BOARD REED RELAYS & COAXIAL
RELAY SERIES
FEATURES
102
120 COAXIAL
OPEN END CONSTRUCTION
WITH METAL COVER
OPEN END CONSTRUCTION
DRY REED
MAGNETIC SHIELDING
SWITCHING UP TO 3.0
AMPS @ 250 VDC.
150 WATT SWITCHING
UP TO 470 MHz.
RG58C/U CABLE, 12"
LONG STANDARD.
50 OHM IMPEDANCE
1 FORM C (DPDT)
R.F. SWITCHING
CONTACTS.
RRN
0.2 GRID SPACING
SINGLE PIECE GLASS FILLED
BOBBIN AND TERMINALSUPPORT
METAL COVER/SHIELD
STANDARD
0.2 GRID SPACING.
VARIOUS CONTACT ARRANGEMENTS.
CONTACT DATA
CONTACT CONFIGURATION:
MAXIMUM CONTACT RATING:
See Catalog Page
SPST-NO
SPDT
MAX SWITCHING
0.5 or 1.0 AMP or 250VDC
@ 10 or 15 VA
MAX SWITCHING
1.0 or 3.0 AMPS or 250VDC
@ 15 or 100 VA
150 Watts up to 470 MHz
MAX.CARRY LOAD 2 or 3.5 AMPS
CONTACT MATERIAL:
CONTACT RESISTANCE:
RHODIUM
RHODIUM
200 MILLIOHMS (INITIAL)
200 MILLIOHMS (INITIAL)
SILVER ALLOY
GOLD FLASHED
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH:
1500 V rms
1500 V rms
1,500 V rms
COIL DATA
DC - VOLTAGE RANGE:
NOMINAL POWER:
6 to 48 VDC
12, 24 VDC
12 VDC
700 mW Max.
800 mW Max
1.44 Watts
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
TIMING VALUES
MAX. OPERATE:
MAX. RELEASE:
LIFE
MECHANICAL:
ELECTRICAL:
DIMENSIONS
MOUNTING POSITION
PAGE NUMBER
PAGE 67
-40 ˚C to + 85 ˚C
6 MILLISECONDS
6 MILLISECONDS
200 MILLION OPERATIONS
10 MILLION OPERATIONS
H
W
L
.641 X 0.74 X 2.50
ANY
PAGE 87, 88
-40 ˚C to + 85 ˚C
5 MILLISECONDS
6 MILLISECONDS
100 MILLION OPERATIONS
20 MILLION OPERATIONS
H
W
L
0.65 X 0.76 X 2.67
ANY
PAGE 89
- 55˚ C to + 65˚ C
15 MILLISECONDS
7 MILLISECONDS
100,000 OPERATIONS
5 MILLION OPERATIONS
H
W
L
.1.62 X.703 X 1.73
ANY
PAGE 90
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
APPLICATION DATA
REED
RELAYS
HOW REED RELAYS WORK
MERCURY-WETTED CONTACT RELAYS. ( CONTINUED)
The term reed relay covers dry reed relays and mercury-wetted
contact relays, all of which use hermetically sealed reed switches.
In both types, the reeds (thin, flat blades) serve multiple functions as conductor, contacts, springs, and magnetic armatures.
DRY REED RELAYS
Dry reed relays have become an important factor in the relay field.
They have the advantage of being hermetically sealed and resistant
to atmospheric contamination. They have fast operate and release
times and when operated within their rated contact loads, have very
long life. A typical dry reed switch capsule is shown in Figure 1.
123456
12345678901234567890123456
123456
123456
12345678901234567890123456
123456
123456
12345678901234567890123456
123456
123456
12345678901234567890123456
123456
123456
12345678901234567890123456
123456
123456
12345678901234567890123456
123456
Supporting
Terminal
Normally
Open
Contacts
Glass
Capsule
Supporting
Terminal
Figure 1. Construction of Switch Capsule of Typical Dry Reed switch (SPST-NO)
In the basic SPST-NO design, two opposing blades are sealed into a
narrow glass capsule and overlapped at their free ends. The contact
area is plated typically with rhodium to produce a low contact resistance
when contacts are drawn together. The capsule is made of glass and
filled with a dry inert gas and then sealed. The capsule is surrounded by
an electromagnetic coil. When the coil is energized, the normally open
contacts are brought together; when the coil voltage is removed, the
blades separate by their own spring tension. Some reeds contain
permanent magnets for magnetic biasing to achieve normally closed
contacts (SPST-NC) or SPDT contact combinations. The current rating,
which is dependent upon the size of the blade and the type and amount
of plating, may range from low level to 1 amp. Effective contact protection
is essential when switching loads other then dry resistive loads.
MERCURY-WETTED CONTACT RELAYS.
Mercury wetted contacts consist of a glass-encapsulated reed with its
base immersed in a pool of mercury and the other end capable of moving
between one or two stationary contacts. The mercury flows up the reed by
capillary action and wets the contact surfaces of the moving end of the
reed as well as the contact surfaces of the stationary contacts. A mercury
to mercury contact is maintained in the closed position. The capsule is
surrounded by an electromagnetic coil and operates in the same manner
as a dry reed.
Supporting
123456
123456 Leadwire
UP
OPERATING
POSITION
Glass
Capsule
Mercury
pool
123456
123456
12345
123456
12345
123456
12345
12345
12345
12345
12345
12345
12345
12345
12345
Movable
12345
12345
contact blade
12345
12345
12345
12345
12345
12345
12345
12345
12345
12345
123456
123456
12345
12345
123456
12345
123456
123456
123456
Figure 2. Miniature Mercury-wetted contact switch (SPDT)
Mercury wetted contacts are fast in operation and have relatively good load
carrying capacity and long life. The mercury films are reestablished at each
contact closure and contact erosion is eliminated.. The mercury films are
stretchable, there is no contact bounce and because it is a mercury contact, the
contact resistance is very low and ideal for low level switching applications.
The disadvantages of this type of reed relay are the freezing point of mercury
(-38˚C), poor resistance to shock and vibration and the need to mount the relay in
a near vertical position.
These relays are used for a variety of switching applications such as found in
computers, business machines, machine tool control systems, and laboratory
instruments.
CONTACT COMBINATIONS.
The switches used in dry reed relays provide SPST-NO, SPST-NC, SPDT contact
combinations.
The SPST-NO corresponds with the basic switch capsule design (Fig.1).
The SPST-NC results from a combination of the SPST-NO switch and
a permanent magnet strong enough to pull the contacts closed but able to open
when coil voltage is applied to the relay coil.
In typical true SPDT designs, the armature is mechanically tensioned
against the normally closed contact, and is moved to the normally open contact
upon application of a magnetic field. The SPDT contact combination can also be
achieved by joining a SPST-NO switch with an appropriately adjusted SPST-NC
switch, and jumping one side of both switches together to form the movable contact
system.
Latching contacts, defined as contacts which remain in the position to
which they were driven, and staying in that position when coil power is removed
from the relay coil.
Latching switches are manufactured by using a SPST-NO contact, and biasing it
with a permanent magnetic that is strong enough to hold the contacts closed,
but not strong enough to hold the contact closed when coil power is applied to the
coil. The switching process is than reversed by simply reversing the relay coil
polarity to close the switch.
MAGNETIC FIELDS
Reed relays in general can be characterized as susceptible to the influences of
external magnetic fields. It is important to keep reed relays at a proper distance
from each other because of the possibility of magnetic-interaction between them.
Proper magnetic shielding must be used to contain stray magnetic fields. When
installing reed relays into equipment, one should be aware of the devices within
that equipment which can produce magnetic fields. The relays being installed into
that equipment should be positioned as far away as possible from any stray
magnetic fields and should be shielded to prevent false operations.
ELECTRICAL CHARACTERISTICS
SENSITIVITY: The input power required to operate dry reed relays is determined
by the sensitivity of the particular reed switch used, by the number of switches
operated by the coil, by the permanent magnet biasing (if used), and the efficiency
of the coil and the effectiveness of its coupling to the blades. Minimum input
required to effect closure ranges from the very low milliwatt level for a single
sensitive capsule to several watts for multipole relays.
OPERATE TIME: The coil time constant, overdrive on the coil, and the characteristics of the reed switch determine operate time. With the maximum overdrive
voltage applied to the coil, reed relays will operate in approximately the 200
microsecond range. When driven at rated coil voltage, usually the relays will
operate at about one millisecond.
RELEASE TIME: With the coil unsuppressed, dry reed switch contacts release
in a fraction of a millisecond. SPST-NO contacts will open in as little as 50
microseconds. Magnetically biased SPST-NC and SPDT switches reclose from
100 microseconds to 1 millisecond respectively.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 68
REED
RELAYS
APPLICATION DATA
ELECTRICAL CHARACTERISTICS (Continued)
RELEASE TIME (Continued)
If the relay coil is suppressed, release times are increased. Diode suppression can delay release times for several milliseconds, depending on coil
characteristics, coil voltage, and reed release characteristics.
CONTACT BOUNCE
Dry reed contacts bounce on closure as with any other hard contact relay.
The duration of bounce on a Dry reed switch is typically very short, and is
in part dependent on drive level. In some of the faster devices, the sum of
the operate time and bounce is relatively constant. As drive is increased, the
operate time decreases with bounce time increasing.
The normally closed contacts of a SPDT switch bounce more then the
normally open contacts. Magnetically biased SPST-NC contacts exhibit
essentially the same bounce characteristics as SPST-NO switches.
NOISE
Noise is defined as a voltage appearing between terminals of a switch for a
few milliseconds following closure of the contacts. It occurs because the
reeds (blades) are moving in a magnetic field and because voltages are
produced within them by magnetostrictive effects. From an application
standpoint, noise is important if the signal switched by the reed is to be used
within a few milliseconds immediately following closure of the contacts.
When noise is critical in an application, a peak-to-peak limit must be
established by measurement techniques, including filters which must be
specified for that particular switching application.
ENVIRONMENTAL CHARACTERISTICS
Reed relays are used in essentially the same environments as other types of
relays. Factors influencing their ability to function would be
temperature extremes beyond specified limits
CONTACT RESISTANCE
VIBRATION
The reeds (blades) in a dry reed switch are made of magnetic material
which has a high volume resistivity, terminal-to-terminal resistance is
somewhat higher than in some other types of relays. Typical specification
limits for initial resistance of a SPST-NO reed relay is 0.200 ohms max
(200 milliohms).
The reed switch structure, with so few elements free to move, has a better
defined response to vibration than other relay types. With vibration inputs
reasonably separated from the resonant frequency, the reed relay will
withstand relatively high inputs, 20 g's or more. At resonance of the reeds,
the typical device can fail at very low input levels. Typical resonance
frequency is 2000 hz.
INSULATION RESISTANCE
SHOCK
A dry reed switch made in a properly controlled internal atmosphere will
have an insulation resistance of 1012 to 1013 ohms or greater. When it is
assembled into a relay, parallel insulation paths reduce this to typical values
of 109 ohms. Depending on the particular manner of relay construction,
exposure to high humidity or contaminating environments can appreciably
lower final insulation resistance.
CAPACITANCE.
Reed capsules typically have low terminal-to-terminal capacitance.
However, in the typicall relay structure where the switch is surrounded by a
coil, capacitance from each reed to the coil act to increase capacitance
many times. If the increased capacitance is objectionable, it can be
reduced by placing a grounded electrostatic shield between the switch and
coil.
Dry reed relays will withstand relatively high levels of shock. SPST-NO
contacts are usually rated to pass 30 to 50 g's, 11 milliseconds, half sign
wave shock, without false operation of contacts. Switches exposed to a
magnetic field that keep the contacts in a closed position, such as in the
biased latching form, demonstrate somewhat lower resistance to shock.
Normally closed contacts of mechanically biased SPDT switches may also
fail at lower shock levels.
TEMPERATURE
Differential expansion or contraction of reed switches and materials used in
relay assemblies can lead to fracture of the switches. Reed relays are
capable of withstanding temperature cycling or temperature shock over a
range of at least -50˚C to + 100˚C. These limits should be applied to the
application to prevent switch failure.
DIELECTRIC WITHSTAND VOLTAGE
CONTACT PROTECTION
With the exception of the High-Voltage dry reed switches ( capsules that
are pressurized or evacuated), the dielectric strength limitation of relays is
determined by the ampere turn sensitivity of the switches used. A typical
limit is 200 VAC. The dielectric withstand voltage between switch and coil
terminals is usually 500 VAC.
Tungsten lamp, inductive and capacitive discharge load are extremely
detrimental to reed switches and reduce life considerably. Illustrated below
are typical suppression circuits which are necessary for maximum contact
life.
FIGURE 3
THERMAL EMF
Input
Since thermally generated voltages result from thermal gradients within the
relay assembly, relays built to minimize this effect often use sensitive
switches to reduce required coil power, and thermally conductive materials
to reduce temperature gradients. Latching relays, which may be operated
by a short duration pulse, are often used if the operational rate is not
changed for longer periods of time because coil power is not required to
keep the relay in the on or off position after the initial turn on or turn off
pulse.
R
Input
R
Initial turn-on current is generally 10 times higher than the rated
operating current of the lamp. A current limiting resistor in series with
the load, or a bleeder resistor across the contacts will suppress the
inrush current. Thesesame circuits can be used with capacitive loads,
as shown in Figure 3.
FIGURE 4
Input
Input
DC inductive loads call for either a diode or a thyristor to be placed across
the load. These circuits are necessary to protect the contacts
when inductive loads are to be switched in a circuit, as shown in Figure 4.
PAGE 69
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SIP
SINGLE IN-LINE PACKAGE REED RELAY
CLASS 117 "SIP"
0.5 AMP SWITCHING
SPST-N.O. OR N.C. CONTACTS
OUTLINE DIMENSIONS
SPECIFICATIONS CLASS 117SIP
Dimensions shown are in "INCHES" & (Millimeters)
Package Material:
Contact Material:
Ambient Temperature:
Dielectric Strength:
Epoxy, molded
Rhodium
- 40˚C to + 85˚C
150 V rms Across open contacts
500 V rms all other points
Insulation Resistance: 1000 Megohms Min.
Capacitance:
1.0 pF typical coil to contacts
Shock Resistance:
50 G's
Vibration Resistance: 20 G's to 200 Hz
1 Millisecond Max.
Operate Time:
1 Millisecond Max.
Release Time:
50 Million operations , 5-10V @ 10 mA
Life
100 Million operations no load
.290 Max.
(7.36)
.750 Max.
(19.5)
.290 Max.
(7.36).260 Max
(6.60)
.075 Max.
(1.90)
.020 Typ.
(.51)
.110
(2.79)
Pin No. 1
Indicator
.200Typ.
(5.08)
.600
(15.2)
.030 Max.
(.762)
.140 Max.
(3.55)
.010 Typ.
(.25)
CONSULT FACTORY FOR COMPLETE PART NUMBER
WITH REQUIRED OPTIONS
MAXIMUM CONTACT RATING
COIL Measured @ 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
CROSS REFERENCE
TO
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
W117SIP-1
5
4.0
0.5
500
50
3621A0500
JWS-117-1
W117SIP-3
12
9.6
1.0
1870
77
3621A1200
JWS-117-3
W117SIP-5
24
19.2
2.0
3200
180
3621A2400
JWS-117-5
W117SIP-22
5
4.0
0.5
500
50
-
JWD-171-12
W117SIP-23
12
9.6
1.0
1200
120
-
JWD-171-14
7 W117SIP-24
24
19.2
2.0
2200
270
-
JWD-171-15
NOMINAL NOMINAL
MAXIMUM MINIMUM RESISSWITCHING CONTINUOUS
POWER
PULL-IN DROPOUT TANCE
CARRY CURRENT
LOAD
(mW)
(OHMS)
HAMLIN
POTTER &
BRUMFIELD
SPST - N.O.
3
1
SPST - N.C.
1
3+
5
5
7
SPST - N.O. WITH CLAMPING DIODE
10VA
0.5 AMP
200VDC
1.5 AMPS
W117SIP-6
5
4.0
0.5
500
50
3621A0510
JWS-117-6
W117SIP-8
12
9.6
1.0
1870
77
3621A1210
JWS-117-8
24
W117SIP-10
7
3+
1
5SPST - N.C. WITH CLAMPING DIODE
19.2
2.0
3200
180
3621A2410
JWS-117-10
1
3+
5-
7
W117SIP-18
5
4.0
0.5
500
50
-
JWD-171-17
W117SIP-25
12
9.6
1.0
1200
120
-
JWD-171-19
W117SIP-26
24
19.2
2.0
2200
220
-
JWD-171-30
NOTE: MAGNECRAFT FOOT PRINT IS IDENTICAL TO COMPETITOR PART NUMBERS SHOWN. COIL RESISTANCE MAY DIFFER
SLIGHTLY FOR THE NOMINAL VOLTAGES SHOWN.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 63
CLASS 107 DUAL IN-LINE PACKAGE REED RELAY
DIP
107 DIP RELAY
EPOXY MOLDED
PROVIDES 4 HOOK-UP
PINS TO COIL.
SPECIFICATIONS CLASS 107DIP
Package Material:
Contact Material:
Ambient Temperature:
Dielectric Strength:
Insulation Resistance:
Capacitance:
Operate Time:
Release Time:
Shock Resistance:
Vibration Resistance:
Life
14
Operating Position:
Weight:
.300
(7.62)
Epoxy, molded
Rhodium
- 40˚C to + 85˚C
150 V rms Across open contacts
500 V rms all other points
1000 Megohms Min.
2.0 pF typical coil to contacts
1 Milliseconds Max @ Nominal.
1 Milliseconds Max @ Nominal.
50 G's
20 G's to 200 Hz
50 Million operations at 5-10V @ 10mA
100 Million operations no load
Any
1 gram approx.
.100 typ.
(2.54)
1
.750 Max.
(19.05)
.275
(6.98)
.020
(0.51)
.020 typ.
(0.51)
.010
(.254)
.150 Typ.
(3.81)
.400
(10.1)
.600
(15.2)
COIL Measured @ 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
RELAY PART NOMINAL MAXIMUM MINIMUM
INPUT
NUMBERS
PULL-IN
DROPOUT
VOLTAGE
MAX. CONTACT RATING
NOMINAL NOMINAL MAXIMUM
MAXIMUM
RESISPOWER SWITCHING CONTINUOUS
TANCE
(mW)
LOAD
(OHMS)
CARRY CURRENT
CROSS
REFERENCE
TO
POTTER &
BRUMFIELD
SPST - N.O.
14 13
9
8
W107DIP-1
5
3.8
0.5
500
50
W107DIP-3
12
9.0
1.0
1200
120
2
6
JWD-107-3
10VA
0.5 AMP
100 VDC
24
18.0
2.0
2200
260
W107DIP-5
5
3.8
0.5
500
50
JWD-107-5
W107DIP-7
12
9.0
1.0
1200
120
JWD-107-7
W107DIP-8
24
18.0
2.0
2200
260
-
W107DIP-4
1
JWD-107-1
7
1.5 AMPS
-
SPST - N.O. WITH CLAMPING DIODE
14 13
9
8
+
1 2
6
7
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
All DIP configurations are available with Magnetic Shielding (internal)
and /or Low level applications on special order.
Contact factory for special part numbers.
SEE SECTION 10 FOR MATING SOCKET
PAGE 71
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SPECIFICATIONS CLASS 172 & 172 DIPS
DIP
SPECIFICATIONS 171DIP & 172 (SPDT)
Package Material:
Contact Material:
Ambient Temperature:
Dielectric Strength:
Epoxy, molded
Rhodium or Mercury (as selected)
- 40˚C to + 85˚C
150 V rms Across open contacts
500 V rms all other points
1000 Megohms Min.
1.0 pF typical coil to contacts
50 G's
20 G's to 200 Hz
1 Millisecond max.
1 Millisecond max.
50 Million operations, 5-10V @ 10mA
100 Million operations Low Level
Insulation Resistance:
Capacitance:
Shock Resistance:
Vibration Resistance:
Operate Time:
Release Time:
Life
171 & 172 (SPDT)
OUTLINE DIMENSIONS
Dimensions shown are in "INCHES" & (Millimeters)
14
.300
(7.62)
1
.100 typ.
(2.54)
.750 Max.
(19.05)
.275
(6.98)
.010
(.254)
.020
(0.51)
.020 typ.
(0.51)
.400
(10.1)
.600
(15.2)
.150 Typ.
(3.81)
SPECIFICATIONS 172DIP (DPDT)
Package Material
Contact Material:
Coil Resistance:
Contact Resistance:
Ambient Temperature:
Dielectric Strength::
Coil to contact:
Insulation Resistance:
Operate Time
Release Time:
Life:
Plastic
Rhodium
± 10% @ 20˚C
150 MΩ max.
- 40˚C to + 85˚C
150 VDC min.
500 VDC min.
1000 Megohms Min.
0.7 Millisecond max. (including bounce)
1 Millisecond max.
50 million operations, 50V/50mA:
80 million operations, 10v/10mA:
PACKAGE STYLE
FOR W172 DIPS
DPDT
Dimensions shown are in "INCHES" & (Millimeters)
PIN 1 LOCATION
.393 ±.003
(10.0)
.750 ±.003
(19.0)
FOOTPRINT AND SCHEMATIC IS PIN FOR PIN
EQUIVALENT TO FORMER DPDT MODELS
.338 ±.003
(8.60)
.125 ±.003
(3.20)
0.10 Typ
(2.54)
.600 ±.003
(15.24)
.082 Typ.
(2.09)
.025
(.635)
.046 Typ.
(1.19)
.300 ±.003
(7.62)
WHEN SPACING DIP RELAYS, EXCEPT FOR THE LATCH VERSION, THE RELAYS REQUIRE 3/4 INCH SPACING FROM THE SIDE
OF THE ADJACENT RELAYS. LATCH RELAYS REQUIRE 1 INCH SPACING BETWEEN ADJACENT RELAYS FROM END TO END
AND CENTER LINE TO CENTER LINE.
SEE SECTION 10 FOR MATING SOCKET
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 72
DUAL IN-LINE PACKAGE REED RELAY
DIP
MIL SPECIFICATION MIL-83516/1 AND /4 VERSIONS AVAILABLE CONSULT FACTORY
MAXIMUM CONTACT RATING
COIL Measured @ 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
PART
NUMBERS
NOMINAL NOMINAL SWITCHING
CONTINUOUS
NOMINAL
MAXIMUM MINIMUM RESISPOWE
LOAD
CARRY CURRENT
INPUT
TANCE
DROPOUT
PULL-IN
(mW)
VOLTAGE
(OHMS)
SPST - N.O.
14 13
CROSS REFERENCE
TO
HAMLIN
POTTER &
BRUMFIELD
HE9
8
W171DIP-2
5
3.8
0.5
500
50
W171DIP-4
12
9.0
1.0
1200
120
W171DIP-5
24
18.0
2.0
2200
270
3.8
0.5
500
50
10VA
0.5 AMP
100VDC
1.5 AMPS
721A0500
-
721A1200
-
721A2400
JWD-171-5
721A0510
-
721A1210
-
721A2410
JWD-171-10
721B0500
JWD-171-12
721B1200
JWD-171-14
721B2400
JWD-171-15
721B0510
JWD-171-17
721B1210
JWD-171-19
721B2410
JWD-171-20
722A0500
JWD-171-21
722A1200
JWD-171-23
722A2400
JWD-171-24
722A0510
JWD-171-25
722A1210
JWD-171-27
722A2410
JWD-171-28
1 2
6 7
SPST - N.O. WITH CLAMPING DIODE
14 13
9
8
+
1 2
6
SPST - N.C.
14 13
9
W171DIP-7
5
W171DIP-9
12
9.0
1.0
1200
120
W171DIP-10
24
18.0
2.0
2200
270
W171DIP-12
5
3.8
0.5
500
50
8
12
9.0
1.0
1200
120
W171DIP-15
24
18.0
2.0
2200
270
1 2
6 7
SPST - N.C. WITH CLAMPING DIODE
14 13
9 8
5
W171DIP-17
3.8
0.5
500
50
+
W171DIP-19
12
9.0
1.0
1200
120
W171DIP-20
24
18.0
2.0
22 00
270
W171DIP-21
5
3.8
0.5
125
125
9.0
1.0
500
300
24
W171DIP-24
1 2
6 7
DPST - N.O. WITH CLAMPING DIODE
18.0
2.0
2000
270
3.8
0.5
200
125
1 2
6
1.5 AMPS
10VA
0.5AMP
100VDC
1.5 AMPS
8
W171DIP-25
+
10VA
0.5 AMP
100VDC
1.5 AMPS
8
12
9
10VA
0.5 AMP
100VDC
7
W171DIP-23
14 13
1.5 AMPS
7
W171DIP-14
1 2
6
DPST - N.O.
14 13
9
10VA
0.5 AMP
100VDC
5
W171DIP-27
12
9.0
1.0
500
290
7 W171DIP-28
24
18.0
2.0
2200
270
10VA
0.5 AMP
100VDC
1.5AMPS
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 171DIP
PAGE 73
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
DUAL IN-LINE PACKAGE REED RELAY
COIL Measured @ 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
PART
NUMBERS
NOMINAL MAXIMUM MINIMUM
INPUT PULL-IN DROPOUT
VOLTAGE
MAGNECRAFT & STRUTHERS-DUNN - SPST-NO LATCHING
14 13
RESET
9
+
6
REFERENCE
TO
POTTER &
BRUMFIELD
8
+
1 2
MAXIMUM CONTACT RATING
CROSS
NOMINAL NOMINAL
SWITCHING CONTINUOUS
RESISPOWER
TANCE
LOAD CARRY CURRENT HAMLIN
(mW)
(OHMS)
HE-
DIP
MRRDL1AS8-5D
5
3.8
0.5
750
35
MRRDL1AS8-12D
12
9.0
1.0
1000
145
MRRDL1AS8-24D
24
18.0
2.0
4600
125
W172DIP-141
5
3.8
0.5
200
125
W172DIP-145
12
9.0
1.0
1000
144
W172DIP-146
24
18.0
2.0
2200
180
3.8
0.5
200
125
10VA
0.5AMP
100VDC
1.5 AMPS
7
OPERATE
SPDT
14 13
2
1
9
6
8
4VA
.25 AMP
100VDC
0.5AMPS
721C0500
JWD-172-155
721C1200
JWD-172-157
721C2400
JWD-172-158
721C0510
JWD-172-159
721C1210
JWD-172-161
721C2410
JWD-172-162
721E0500
-
721E1200
-
721E2400
-
721E0510
-
721E1210
-
721E2410
-
7
SPDT WITH CLAMPING DIODE
14 13
9
8
W172DIP-147
1
+
2
SPDT
14 13
6
9
7
5
W172DIP-149
12
9.0
1.0
1000
144
W172DIP-150
24
18.0
2.0
2200
180
W172DIP-31
5
3.8
0.5
500
125
12
9.0
1.0
1000
290
W172DIP-34
24
18.0
2.0
2200
270
6 7
1 2
SPDT WITH CLAMPING DIODE
14 13
9 8
W172DIP-35
5
3.8
0.5
500
125
+
2
6
0.5AMPS
8
W172DIP-33
1
4VA
.25 AMP
100VDC
W172DIP-37
12
9.0
1.0
1000
300
W172DIP-38
24
18.0
2.0
2200
270
4VA
.25 AMP
100VDC
4VA
.25 AMP
100VDC
0.5AMPS
0.5 AMPS
7
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 74
DIP
DUAL IN-LINE PACKAGE REED RELAY
171 & 172 (SPDT)
COIL Measured @ 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
PART
NUMBERS
MAXIMUM CONTACT RATING
NOMINAL NOMINAL
NOMINAL
SWITCHING CONTINUOUS
MAXIMUM MINIMUM RESISPOWER
INPUT
LOAD
CARRY CURRENT
PULL-IN DROPOUT TANCE
(mW)
VOLTAGE
(OHMS)
CROSS REFERENCE
TO
HAMLIN
HE-
POTTER &
BRUMFIELD
SPDT
14 13
1
2
9
6
8
W172DIP-1
5
3.8
0.5
200
125
W172DIP-3
12
9.0
1.0
500
300
W172DIP-4
24
18.0
2.0
2200
270
W172DIP-5
5
3.8
0.5
200
125
W172DIP-7
12
9.0
1.0
500
300
W172DIP-8
24
18.0
2.0
2200
270
7
4VA
.25 AMP
100VDC
0.5 AMPS
721R0500
JWD-172-1
721R1200
JWD-172-3
721R2400
JWD-172-4
721R0510
JWD-172-5
721R1210
JWD-172-7
721R2410
JWD-172-8
SPDT WITH CLAMPING DIODE
14 13
1
+
2
9
6
8
7
4VA
.25 AMP
100VDC
0.5 AMPS
SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 172DIP (SPDT)
PACKAGE STYLE
FOR W172 DIPS
DPDT
COIL Measured @ 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
PART
NUMBERS
MAXIMUM CONTACT RATING
NOMINAL NOMINAL
NOMINAL
SWITCHING CONTINUOUS
MAXIMUM MINIMUM RESISPOWER
INPUT
LOAD
CARRY CURRENT
PULL-IN DROPOUT TANCE
(mW)
VOLTAGE
(OHMS)
DPDT
14 13
1 2
9
6
8
W172DIP-17
5
3.8
0.3
46
540
W172DIP-19
12
9.0
0.3
266
540
W172DIP-20
24
18.0
0.3
1066
540
W172DIP-21
5
3.8
0.3
46
540
W172DIP-23
12
9.0
0.3
266
540
W172DIP-24
24
18.0
0.3
1066
540
10VA
0.5 AMP
100VDC
1.0 AMPS
10VA
0.5 AMP
100VDC
1.0 AMPS
7
DPDT WITH CLAMPING DIODE
14 13
+
1 2
9
6
8
172 DIPS WITH DPDT
CONTACT ARRANGEMENTS
HAVE A NEW PACKAGE
STYLE.
NEW PACKAGE SWITCHES
HIGHER CURRENT UP TO 0.5
AMP @ 100 VDC
7
SEE SPECIFICATIONS AND OUTLINE DIMENSIONS FOR 172DIP (DPDT)
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 75
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
GENERAL SPECIFICATIONS MINIATURE REED RELAYS
MINIATURE
REED
OUTLINE DIMENSIONS
1.15 Max.
(29.2)
DIMENSIONS SHOWN ARE IN INCHES AND ( MILLIMETERS )
.355
(9.0)
.125 (3.2) Typ.
1.00
(25.4)
.400
(10.16)
SIZE I
.050
(1.27) Typ.
Slotted holes for
Terminal Pins.
.075
(1.9)
SIZE II
.500
(12.7)
.100
(2.54) Typ.
.900
(22.86)
SIZE IV
.700
(17.8)
SIZE III
BOTTOM VIEW ALL SIZES
STANDARD PRINTED CIRCUIT RELAY HAS 1.00" X 0.1" GRID SPACING
SIZE I
RELAY CLASS
CONTACT CONFIGURATION:
SIZE II
CONTACT RATING MAX. (Resistive Load):
SWITCHING VOLTAGE MAX.
SWITCHING CURRENT MAX.
CARRY CURRENT MAX.
101/193
104/193
SPST-NO
SPST-NO
Latching
(SPST-NO)
3PST-NO
Latching
up to 6PST-NO
SPDT, DPDT
for 104 Series
10 VA
200DC/130 AC
0.5 AMPS
2 AMPS
4VA
100 VDC
0.5 AMPS
1 AMPS
INITIAL CONTACT RESISTANCE
( IN MILLIOHMS ):
SPDT,DPDT,
3PDT,4PDT
(193 Series)
200 Milliohms Max.
INSULATION RESISTANCE (Ohms)
TESTED AT 100 VDC:
131
134
SPST-NO
or
DPST-NO
Mercury
Mercury
(SPDT)
Mercury
DPDT
50VA
500 VDC
2 AMPS
3 AMPS
50VA
500 VDC
2 AMPS
3 AMPS
100 Milliohms Max. Contact
resistance Stability ± 10% over Life.
109 Min.
1010 Min.
1010 Min.
200 VDC
1000 VDC
1000 VDC
500 VDC
1000 VDC
1000 VDC
.3pF
2.0 pF
3.0pF
.9pF
2.0 pF
2.5pF
SIZE III
DIELECTRIC STRENGTH:
MIN. ACROSS OPEN CONTACTS:
MIN. BETWEEN MUTUALLY
INSULATED POINTS:
CAPACITANCE: ( non-shielded relay)
ACROSS OPEN CONTACTS:
OPEN CONTACTS TO COIL:
CLOSED CONTACTS TO COIL:
SIZE IV
TEMPERATURE:
MAX. AMBIENT OPERATING (˚C )
TEMPERATURE:
MIN. AMBIENT OPERATING ( ˚C )
STORAGE TEMPERATURE:
MOUNTING POSITION:
LIFE AT RATED LOAD:
With appropriate Contact protection
( End of life 1 Ohm )
OPERATE TIME: (Typical- in Micro-Sec.]).
TYPICAL RELEASE TIME: (in Micro-Sec.)
Diode Suppression:
No Suppression:
PACKAGING:
.
3pf Typical
Form "A" 2.0 pF Typ.
Form "C" 3.0pF Typ.
85 ˚C or ( 120 ˚C -70˚ x [ Coil Power]) whichever is lower
- 40˚C
- 60˚C to + 105˚C
ANY
- 37˚C
- 40˚C to + 105˚C
Vertical ± 15˚
40 x 108
3 x 108
at low level
50 x 108
5 x 108
at low level
1.0 mS, for N.O.
1.0 mS, for N.C.
2.0 mS, for
N.O.
2300 µS
2000 µS
1.0 mS, for N.O.
1.5 mS, for N.C.
1.0 mS for NO
1.5 mS for NC
10 Million Operations
100 Million Operations
at Low level
2.0 mS
2.5 mS
Dust covered, Epoxy Encapsulated is Standard.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 76
MINIATURE
CLASS 101 DRY MINIATURE REED RELAY
REED
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS
AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS
WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART
NUMBERS. NON-STANDARD SCHEMATICS AND PIN-OUTS CAN
ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
SIZE I
Spacing between filled in circles in schematics are on
a .100 Grid Pattern. Pin omitted on unfilled circles.
.100
(2.54) Typ.
SIZE III
COIL MEASURED AT 25˚C
CIRCUIT
DIAGRAM
TOP VIEW
CASE
SIZE
PART
NUMBERS
MAX. CONTACT RATING
NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL
MAX.
SWITCHING
POWER SWITCHING CURRENT & CARRY
INPUT
PULL-IN DROPOUT RESISTANCE
CURRENT
(mW)
VOLTAGE
LOAD
VOLTAGE
(OHMS)
SPST-NO
6
5
I
1
W101MPCX-2
W101MPCX-3
12
24
9.0
18.0
1.0
2.0
1400
3300
102
175
W101MPCX-5
W101MPCX-6
W101MPCX-7
5
12
24
4.0
9.0
18.0
0.5
1.0
2.0
90
430
1500
425/425
2500/2500
10 VA
0.5 AMP
200 VDC
2 AMPS
280
340
380
10 VA
0.5 AMP
200 VDC
2 AMPS
60
60
10 VA
0.5 AMP
200 VDC
2 AMPS
2
3PST-NO
12
11
III
1
2
SPST-NO MAGNETIC LATCH
11
De-Latch
(Reset)
+
12
W101LMPCX-16
W101LMPCX-17
III
Latch
(Set)
1
5/5
12/12
3.8
9.0
To Set
or Reset
-
+
2
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 77
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE
CLASS 131 MERCURY
REED
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS
AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS
WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART
NUMBERS. NON-STANDARD SCHEMATICS AND PIN-OUTS CAN
ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
SIZE I
Spacing between filled in circles in schematics are on
a .100 Grid Pattern. Pin omitted on unfilled circles.
.100
(2.54) Typ.
SIZE II
SPST-NO MERCURY
UP
5
6
W131MPCX-3
W131MPCX-4
1
1
12
24
9.0
18.0
1.0
2.0
330
1400
435
410
50 VA
2.0 AMP
500 VDC
3 AMPS
50 VA
2.0 AMP
500 VDC
3 AMPS
2
DPST-NO MERCURY
UP
9
10
W131MPCX-7
W131MPCX-8
II
1
12
24
9.0
18.0
1.0
2.0
230
1200
626
480
2
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
For Class 131 allow a minimum of 30 seconds after mounting for excess Mercury to clear from the contacts before using.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 78
MINIATURE
CLASS 104 DRY MINIATURE REED RELAY
REED
SIZE I
PIN SPACING OF .100" IS STANDARD. PIN SPACING OF .150 IS
AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS
WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART
NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN
ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
Spacing between filled in circles in schematics are on
a .100 Grid Pattern. Pin omitted on unfilled circles.
.100
(2.54) Typ.
SIZE III
CASE
SIZE
CIRCUIT
DIAGRAM
TOP VIEW
PART
NUMBERS
COIL MEASURED AT 25˚C
MAX. CONTACT RATING
NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL MAX.
SWITCHING
POWER SWITCHING CURRENT & CARRY
INPUT
PULL-IN DROPOUT RESISTANCE
CURRENT
(mW)
VOLTAGE
LOAD
VOLTAGE
(OHMS)
SPDT
6
5
W104MPCX-3
I
1
24
18.0
2.0
2600
220
4 VA
0.25 AMP
100VDC
0.5 AMPS
9.0
1.0
230
626
4 VA
0.25 AMP
100VDC
0.5 AMPS
4.0
9.0
18.0
0.5
1.0
2.0
45
230
1200
4 VA
0.25 AMP
100VDC
0.5 AMPS
2
DPDT
9
10
II
W104MPCX-6
1
12
2
DPDT
7
8
W104MPCX-149
W104MPCX-150
W104MPCX-151
II
1
5
12
24
556
626
480
2
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 79
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE
CLASS 134 MERCURY
REED
SIZE I
PIN SPACING OF .100" IS STANDARD. PIN SPACING OF .150 IS
AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS
WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART
NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN
ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
Spacing between filled in circles in schematics are on
a .100 Grid Pattern. Pin omitted on unfilled circles.
.100
(2.54) Typ.
SIZE II
DPDT MERCURY
UP
8
7
W134MPCX-7
W134MPCX-8
II
1
5
12
4.0
9.6
0.5
1.0
45
230
560
620
50 VA
1.0 AMP
500 VDC
2.0 AMPS
2
DPDT MERCURY WITH CLAMPING DIODE
+
UP
8
7
W134MPCX-10
W134MPCX-11
II
-
1
5
12
4.0
9.6
1.0
1.0
45
230
560
620
50 VA
1.0 AMP
500 VDC
2.0 AMPS
5
12
24
4.0
9.0
18.0
0.5
1.0
2.0
60
330
1400
417
435
410
50 VA
1.0 AMP
500 VDC
2.0 AMPS
2
SPDT MERCURY
5
UP
6
I
1
W134MPCX-1
W134MPCX-2
W134MPCX-3
2
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
For Class 134 allow a minimum of 30 seconds after mounting for excess Mercury to clear from the contacts before using.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 80
MINIATURE
CLASS 193 DRY MINIATURE REED RELAY
REED
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS
AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS
WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART
NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN
ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
SIZE I
Spacing between filled in circles in schematics are on
.100 Grid Patterns. Pin omitted on unfilled circles.
.100
(2.54) Typ.
SIZE II
CIRCUIT
DIAGRAM
(Top View)
CASE
SIZE
PART
NUMBERS
COIL MEASURED AT 25˚C
MAX. CONTACT RATING
NOMINAL NOMINAL MAX.
NOMINAL MAXIMUM MINIMUM
SWITCHING CARRY
POWER SWITCHING CURRENT &
INPUT
PULL-IN
DROPOUT RESISCURRENT
TANCE
(mW)
VOLTAGE
VOLTAGE
LOAD
(OHMS)
SPST-N.O.
I
1
3
5
2 W193RE1A3-5S
4
4.0
9.0
18.0
0.5
1.0
2.0
500
420
2300
5
4.0
0.5
350
70
W193RE1C3-12G
12
9.0
1.0
420
350
W193RE1C3-24G
24
18.0
2.0
2300
250
W193RE1A3-12G
6
W193RE1A3-24G
5
12
24
50
350
250
10 VA
0.5 AMP
200 VDC
2 AMPS
4 VA
0.5 AMP
100 VDC
1 AMP
10 VA
0.5 AMP
200 VDC
2 AMP
4 VA
0.5 AMP
100 VDC
1 AMP
SPDT
I
1
3
2
4
5
6
W193RE1C3-5S
DPST-N.O.
II
5
4.0
0.5
70
360
6 W193RE2A3-12G
8
12
9.0
1.0
280
500
W193RE2A3-24G
24
18.0
2.0
1500
390
5
4.0
0.5
70
360
12
9.0
1.0
280
500
24
18.0
2.0
1500
390
1
3
2 W193RE2A3-6G
4
5
7
DPDT
II
1
3
2 W193RE2C3-6G
4
5
6 W193RE2C3-12G
7
8
W193RE2C3-24G
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 81
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
MINIATURE
CLASS 193 DRY MINIATURE REED RELAY
REED
PIN SPACING OF 0.100" IS STANDARD. PIN SPACING OF 0.150 IS
AVAILABLE ON SPECIAL ORDER. ALSO AVAILABLE ARE MODELS
WITH ELECTROSTATIC SHIELDS. CONSULT FACTORY FOR PART
NUMBERS. NONSTANDARD SCHEMATICS AND PIN-OUTS CAN
ALSO BE PRODUCED FOR SPECIFIC CUSTOMER REQUIREMENTS.
SIZE III
Spacing between filled in circles in schematics are on
.100 Grid Patterns. Pin omitted on unfilled circles.
.100
(2.54) Typ.
SIZE IV
CIRCUIT
DIAGRAM
(Top View)
CASE
SIZE
PART
NUMBERS
MAX. CONTACT RATING
COIL MEASURED AT 25˚C
NOMINAL NOMINAL MAX.
NOMINAL MAXIMUM MINIMUM
SWITCHING CARRY
POWER SWITCHING CURRENT &
INPUT
PULL-IN
DROPOUT RESISCURRENT
TANCE
(mW)
VOLTAGE
VOLTAGE
LOAD
(OHMS)
3PST-N.O.
III
1
3
2
4
5
7
9
6
8
10
W193RE3A3-6G
5
4.0
0.5
50
500
W193RE3A3-12G
12
9.0
1.0
210
690
W193RE3A3-24G
24
18.0
2.0
1150
500
W193RE3C3-6G
5
4.0
0.5
50
500
W193RE3C3-12G
12
9.0
1.0
210
690
W193RE3C3-24G
24
18.0
2.0
1150
500
W193RE4A3-6G
5
4.0
0.5
50
500
W193RE4A3-12G
12
9.0
1.0
210
690
W193RE4A3-24G
24
18.0
2.0
1150
500
10 VA
0.5 AMP
200 VDC
2 AMP
4 VA
0.5 AMP
100 VDC
1 AMP
10 VA
0.5 AMP
200 VDC
2 AMP
4 VA
0.5 AMP
100 VDC
1 AMP
3PDT
1
3
III
5
7
9
2
4
6
8
10
11
12
4PST-N.O.
III
1
3
5
7
9
11
2
4
6
8
10
12
4PDT
IV
1
2
3
4
5
7
6
8
W193RE4C3-6G
5
4.0
0.5
35
720
9
10
W193RE4C3-12G
12
9.0
1.0
140
1030
11
13
12
W193RE4C3-24G
24
18.0
2.0
770
750
15
14
16
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 82
SERIES
P.C. TERMINAL, MOLDED MINIATURE REED RELAY
MR-Y
The MR-Y Series epoxy molded miniature reed relay has terminal pins on each end and
spaced 1 inch apart. It is available with two grid spacings - 0.1 inch or 0.15 inch. Available
contacts range from SPST-NO to DPDT configurations. As an option, Mercury reeds are
available in limited contact configurations. Lower power coils are also available in addition to
optional diode across the coil and electrostatic shielding.
WIRING DIAGRAM
Top View
+
*
+
+
SPST-NO
MR30Y1A
MR35Y1A
+
SPST-NC
MR30Y1B
MR35Y1B
*
DPST-NO
MR30Y2A
MR35Y2A
+
*
*
DPDT
MR30Y2C
MR35Y2C
SPDT
MR30Y1C
MR35Y1C
OUTLINE DIMENSIONS
Dimensions shown are in Inches and (Millimeter)
.950
(24.1)
.550
(13.9)
.400
(10.1)
.312
(7.9)
.130
(3.3)
.010
(.254)
.045 Typ.
(1.14)
.020 Typ.
(.508)
DIM. "A" SEE CHART
DIM. "B" SEE CHART
DIMENSION CHART
DIM "A"
0.100 0.10 Grid
DIM."A"
0.150 0.15 Grid
DIM "B"
0.200 0.10 Grid
DIM."B"
0.300 0.15 Grid
Position Reference
.062 R x .032 Deep
1.00
(25.4)
PAGE 83
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
P.C. TERMINAL, MOLDED MINIATURE REED RELAY
MR-Y
SPECIFICATIONS MR-Y
(Not all Data applies to HG Relays)
Package Material:
Contact Material:
Dielectric Strength:
Epoxy, molded
Rhodium
200 V rms Across Open Contacts
1500 V rms All other points
Insulation Resistance:
1000 Megohms Min.
Capacitance:
0.4 pF typical coil to contacts
Shock Resistance:
50 G's
Vibration Resistance:
20 G's to 2000 Hz
Operate & Release Time: 2 Milliseconds Max.
Life:
10 Million operations at rated load SPST,DPST-NO & NC
100 Million operations no load SPST,DPST-NO & NC
5 Million operations at rated load SPDT, DPDT contacts.
50 Million operations no load, SPDT, DPDT contacts.
CONTACT DATA
Material - Rhodium on Dry Reeds
COIL DATA
Power Consumption (mW) - Coil Resistance,
Nominal Voltage
± 10% @ 25˚C
SPST, DPST
SPDT, DPDT
VDC OHMS
mW
mW
OHMS
167
5
313
150
80
12
250
450
575
320
24
268
384
2150
1500
Max. VDC
Contacts
200
SPST-NO
200
SPST-NC
28
SPDT, DPDT
500
SPST-NO (HG)
200
SPDT, DPDT(HG)
Max. mA
500
500
250
2000
1000
VA
10
10
3
50
28
Must operate at 80% of nominal voltage @ 25˚C
Low Power Coils available:
Single Pole - 25mW
Double Pole - 65mW
Struthers-Dunn
ORDERING CODE
Typical Type No.
MR30Y
2A
RV -12D
Series
MR30Y- 0.1 grid, end terminal
Min. P.C. Reed Relay
MR35Y- 0.15 grid, end terminal
Min. P.C. Reed Relay
Contact Arrangements
1A - SPST-NO
2A - DPST-NO
1B - SPST-NC
1C - SPDT
2C - DPDT
Options
Electrostatic Shield (see wiring diagrams)- CODE E
Low Power Coils (Dry Reeds Only) - CODE R
Diode across Coil (Observe Polarity) - CODE V
Mercury Reed Contact, position sensitive
SPST-NO or SPDT - CODE Z
Coil Voltage (DC only)
DC: 5, 12, 24 (Add "D")
+ Polarity must be observed for models with Form "B" contacts or optional Diode.
*
Terminal for optional Electrostatic Shield.
HG Contact relays are position sensitive.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 84
SERIES
MRR & RR
AXIAL LEAD, SHIELDED REED RELAY
The MRR and RR Series Axial lead epoxy molded reed relays have solid wire
leads on each end. They are available with two grid spacings - 0.1 inch for the
MRR series and 0.2 inch for the RR series. Available contacts - UP TO 12PSTNO for the MRR series, and 1 -4PST-NO or NC for the RR series. The MRR and
RR series come with an external Half shield fixed to the body of the relay.
WIRING DIAGRAM (Terminal view )
MRR4A,
RR4AF
MRR3A,
RR3A
MRR2A,
RR2A
MRR1A,
RR1A
RR1B
DIMENSIONAL CHART FOR MRR & RR SERIES RELAYS
SERIES
A
MRR1A
MRR2A
MRR4A
RR1A, RR1B
RR2A
RR4AF
B
C
DIMENSIONS (Inches)
D
E
F
G
H
1.062 .425 .425
.018 X .030
± .005 .440 .515 .500 .500 .028
.028
.535 .810
.655 .655
.055
1.875 .670 .840 .875 .500 .035 .035 X .061
.810 1.385
To convert Inch dimensions to Millimeter use 25.4 x Dimension = Millimeters.
OUTLINE DIMENSIONS
See dimensional chart above
F
H
MRR4A,
RR4AF
C
Max.
F
H
MRR2A,
RR2A
G
B
Max.
C
Max.
F
H
MRR1A,
RR1A, RR1B
Min.
D
B
Max.
G
Min.
A
Typical Lead spacing .115"
Typical Lead spacing .115"
PAGE 85
G
E
B
Max.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
SERIES
AXIAL LEAD, SHIELDED REED RELAY
MRR & RR
SPECIFICATIONS MRR & RR
Contact Material:
Ambient Temperature:
Dielectric Strength:
Insulation Resistance:
Capacitance:
Shock Resistance:
Vibration Resistance:
Operate & Release Time:
Life:
Rhodium
- 40˚C to + 85˚C
MRR 400 V rms Across open contacts
RR 500 V rms Across open contacts
1500 V rms All other points
1000 Megohms Min.
0.4 pF typical coil to contacts
50 G's
MRR - 20 G's to 2000 Hz
RR - 10 G's to 450 Hz
2 to 10 Milliseconds based on the
amount of contacts.
10 Million operations at rated load
200 Million operations no load
COIL DATA MRR SERIES
Coil Resistance & Nominal Voltage Measured
at ± 10% @ 25˚C.
SPST-NO DPST-NO 4PST-NO 12PST-NO
OHMS
OHMS
VDC
OHMS
OHMS
24
72
6
144
288
94
288
12
576
1152
384
1152
24
2300
4600
1536
3300
48
COIL DATA RR SERIES
Coil Resistance & Nominal Voltage Measured
at ± 10% @ 25˚C.
DPST-NO
4PST-NO
SPST-NO or NC
OHMS
OHMS
OHMS
VDC
24
90
36
6
94
360
145
12
384
1440
580
24
1536
5760
2300
48
Must operate at 80% of nominal voltage @ 25˚C
Must operate at 70% of nominal voltage @ 25˚C
Options RR only - Preformed leads welded lead extensions.
CONTACT DATA RR SERIES
Material - Rhodium on Dry Reeds
CONTACT DATA MRR SERIES
Material - Rhodium on Dry Reeds
Contacts
1-4PST-NO
Max. VDC
200
Max. mA
500
VA
10
Contacts
1-4PST-NO
SPST-NC
Max. VDC
250
250
Max. AMPS
1.0
1.0
VA
15
15
NOTE: Voltage, Current, and Power ratings in the tables above are independent maximums and no single value
is to be exceeded. Ratings are based on noninductive, straight resistive, AC or DC loads without inrush. Other
loads require contact protection and /or de-rating.
Struthers-Dunn
ORDERING CODE
Typical Type No.
MRR or RR 2A
-12D
Series
MRR- 0.1" Lead spacing
RR- 0.2" Lead spacing
Contact Arrangements
1A - SPST-NO
2A - DPST-NO
3A - 3PST-NO
4A - 4PST-NO
1B - SPST-NC (RR series Only)
Coil Voltage (DC only)
DC: 6, 12, 24, 48 (Add "D")
(5 volt and other voltages available)
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 86
series
RRN
OPEN STYLE, METAL COVER/SHIELD REED RELAY
The RRN Series is a open construction, one piece nylon bobbin,
P.C. terminal assembly with a metal Cover/Shield (3 sided).
* WIRING DIAGRAMS
(Top View)
RRN1A
RRN2A
.740 Wide
.958 Wide
RRN1C
RRN1B
.740 Wide
.958 Wide +
RRN3A
1.188 Wide
RRN2B
1.188 Wide
+
RRN4A
RRN2C
RRN3C
1.418 Wide
1.418 Wide
1.418 Wide
OUTLINE DIMENSIONS
Shown in Inchs and (Millimeters)
* See Wiring Diagrams for Width.
2.50 Max.
(63.5)
*
.64 Max.
(16.2)
0.156
(3.9)
1.90 Max.
(48.2)
.38
(9.6)
.200
(5.0)
0.10
(2.54)
.800
(20.3)
.500
(12.7)
2 POLE CASE SIZE
Terminals on 0.2 Inch grid. The 1 and 3
pole units have the middle terminals on
the center line.
PAGE 87
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
series
OPEN STYLE, METAL COVER/SHIELD REED RELAY
RRN
SPECIFICATIONS RRN
Contact Material:
Ambient Temperature:
Dielectric Strength:
Insulation Resistance:
Capacitance:
Shock Resistance:
Vibration Resistance:
Operate Time:
Release Time:
Life:
Rhodium
- 40˚C to + 85˚C
500 V rms Across open contacts
1500 V rms All other points
1000 Megohms Min.
0.4 pF typical coil to contacts
50 G's
RR - 10 G's to 450 Hz
6 Milliseconds max. depending on 6 Milliseconds worst case.
10 Million operations at rated load
200 Million operations no load
all 1-4PST-NO & SPST-NC
50 Million Operations at no load
for all SPDT, DPDT Contacts.
CONTACT DATA
Contacts
Max. VDC
1-4PST-NO
250
1-2PST-NC
250
SPDT, DPDT
250
COIL DATA
Coil Resistance & Nominal Voltage Measured at ± 10% @ 25˚C
NOM.
VDC
6
12
24
48
1 POLE
OHMS
150
600
2400
4000
2 POLE
OHMS
100
400
1600
4000
3 POLE
OHMS
50
200
800
3000
4 POLE
OHMS
40
150
600
2300
Max. Amps
1.0
1.0
0.5
VA
15
15
10
NOTE: Voltage, Current, and Power ratings in the table
above are independent maximums and no single value is
to be exceeded. Ratings are based on noninductive,
straight resistive, AC or DC loads without inrush. Other
loads require contact protection or de-rating.
Must operate at 80% of nominal voltage @ 25˚C
Struthers-Dunn
ORDERING CODE
Typical Type No.
RRN
3A
EV
-12D
Series
RRN- Semi open, 3 sided shield
Contact Arrangements
1A - SPST-NO
2A - DPST-NO
3A - 3PST-NO
4A - 4PST-NO
1B - SPST-NC
2B -DPST-NC
1C - SPDT
2C - DPDT
Options
Electrostatic Shield (Consult Factory For Wiring Code E
Diode Across Coil (Observe Polarity, Consult Factory) Code
V
Coil Voltage (DC only)
DC: 6, 12, 24, 48 (Add "D")
(5 volt and other voltages available)
SPECIAL OPTIONS
Special Wiring .
Magnetic Latch Version .
Consult Factory
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 88
CLASS
OPEN STYLE, METAL COVER/SHIELD REED RELAY
102
102MPCX/RMPCX
SPST-N.O.
METAL SHIELD ON THREE SIDES.
0.2 GRID SPACING.
OUTLINE DIMENSIONS
Dimensions shown are in Inch and (Millimeter)
.760 Max.
(19.3)
2.67 Max.
(16.5)
.65 Max.
(16.5)
1.90 Max.
(48.2)
0.16
(4.0)
.38
(9.6)
.200
(5.0)
.18 Max.
(4.5)
.400
(10.1)
1 POLE CASE SIZE
GENERAL SPECIFICATIONS 102
102
102R
RELAY CLASS
Contact Resistance Initial:
200
200
Dielectric Withstanding voltage:
Across Open Contacts:
700 VDC 450 VDC
Between all other mutually
Insulated points.:
1000 VDC
Operate Time (mS):
Bounce Time No Diode (mS):
CIRCUIT
DIAGRAM
(TOP VIEW)
1.0
2
PART
NUMBERS
2.0
2
RELAY CLASS
Capacitance, Non Shield, N.O.:
Insulation Resistance:
Coil Dissipation (mW)
Mounting Position:
Shock (Non operation):
Vibration:
Temperature Range (operating):
Life At rated load:
102
102R
1.0 pf
1.5 pf
109 at 100 VDC
50 to 1.5W
600
Any
30 G's 11mS ± 1 mS 1/2 Sign
10 G"s 10 to 1000 Hz
-40˚C to + 85˚C
200 Million
20 Million
@1A, 115V rms
COIL MEASURED AT 25˚C
MAX. CONTACT RATING
NOMINAL MAXIMUM MINIMUM NOMINAL NOMINAL SWITCHING SWITCHING
CARRY
RESISINPUT
PULL-IN DROPOUT TANCE POWER
CURRENT &
LOAD
CURRENT
(mW)
VOLTAGE
VOLTAGE
(OHMS)
SPST-N.O. 1 AMP
W102MPCX-7
12
9.0
1.0
250 Ω
W102MPCX-8
24
18.0
2.0
1000 Ω
12
9.0
1.0
250 Ω
580 mW
15VA
1 AMP
250VDC
2 AMPS
3 AMP
250VDC
3.5 AMPS
SPST-N.O. 3 AMP
W102RMPCX-2
580 mW
W102RMPCX-3
24
18.0
2.0
1000 Ω
100VA
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 89
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
150 WATT, COAXIAL R.F. SWITCHING RELAY
120
120 COAXIAL RELAY
PANEL MOUNT WITH RG58C/U
CABLE (50 OHM )
SWITCHING UP TO 470 MHz
1.73
(44.0)
RG58C/U
RG58C/U
.312
(7.93)
12.0
(304.8)
.120 Dia thru holes
(2 mounting holes)
.671
(17.0)
12.0
(304.8)
1.106
(29.05)
.422 .770
(10.71) (19.5)
.250 Typ.
(6.35)
WIRING DIAGRAM
Side View Coil Down
.078
(1.98)
.850
(21.59)
.093
(2.38)
2
1
3
1.28
(32.5)
4
5
GENERAL SPECIFICATIONS CLASS 120
CONTACTS
R.F. Load rating:
Contact Configuration:
Contact Resistance (Initial):
VSWR ( Voltage Standing Wave Ratio)
Cross Talk:
150 Watts max. up to 470 MHz
SPDT (1 Form "C")
50 Milliohms max.
1.25 to 1 max., up to 460 MHz
40 DB min., up to 470 MHz.
TIMING
Operate Time:
Release Time:
15 mS Max. @ Nominal Voltage.
7 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated current
carrying parts to ground:
Insulation Resistance:
1000 V rms @ Sea level
1000 Megohms min. 500 V
TEMPERATURE
Rated Operation:
-55˚C to +65˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
100,000 Operations @ Rated Load.
5 Million Operations no load
MISCELLANEOUS
Mounting:
Connectors:
Cable Type:
Panel mount with 2 mount holes.
None
RG58C/U, 12" long, with stripped wire
length of .250"
50 Ohms
3 ozs. 85.0 grams approx.
Cable Impedance:
Weight:
COIL Measured @ 25˚C
PART NUMBER
CONTACT
CONFIGURATION
NOMINAL
INPUT
VOLTAGE
NOMINAL
RESISTANCE
(OHMS)
DC OPERATED
W120X-14
SPDT
12 VDC
100
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 90
S E C T I O N
4
4
SOLID STATE RELAYS
(SSR)
1.5 TO 75 AMPERES
Page 91
Magnecraft
Struthers-Dunn
SOLID STATE RELAYS
RELAY SERIES
230E & 230T
226
231
CLASS 6 (DTX)
NEW!
L.E.D.
L.E.D INDICATES RELAY
IS IN THE OPERATE MODE.
FEATURES
L.E.D. "ON" LAMP
5 OR 12 VDC INPUT
AC, TRIAC OUTPUT
P.C. MOUNT STYLE.
UP TO 7 AMP LOADS
5 OR 12 VDC INPUT
AC OUTPUT
PHOTO ISOLATED,
RANDOM TURN-ON
COMPATABLE WITH
TTL GATES.
MOUNTS ON TO-3
TRANSISTOR HEAT
SINKS FOR ADDED
CURRENT RATING.
OUTPUT DATA
TYPE 230E HAS 1.5
AMP LOAD RATING
TYPE 230T HAS 3.0
AMP LOAD RATING
ZERO VOLTAGE
SWITCHING.
TYPE 230T HAS
BUILT IN HEAT SINK.
Q.C. TERMINAL,
FLANGE MOUNT
STYLE.
DC CONTROLLED
INPUT, AC TRIAC
OUTPUT
5 OR 12 VDC INPUT
AC OUTPUT UP TO
4 AMP LOADS.
UP TO 10 AMP LOADS
ZERO VOLTAGE
SWITCHING.
FLANGE ALSO
SERVES AS THE
HEAT SINK.
PHOTO ISOLATED,
ZERO VOLTAGE
SWITCHING.
4000 V rms ISOLATION
INPUT TO OUTPUT.
INTERNAL RC
(SNUBBER) NETWORK
OUTPUT CONFIGURATION:
SPST-NO
SPST-NO
SPST-NO
SPST-NO
SPST-NO
MAXIMUN ALLOWABLE
OUTPUT VOLTAGE & LOAD:
7 AMPS @
260 OR 380 VAC
1.5 AMPS
@
140 OR
280VAC
3.0AMPS
@
140 OR
280 VAC
4 AMPS @
140 OR 280 VAC
10 AMPS @
140 OR 280 VAC
(230E)
(230T)
OUTPUT DEVICE:
MINIMUM LOAD:
TRIAC
SCR
SCR
TRIAC
50 MILLIAMPS
25 MILLIAMPS
25MILLIAMPS
50 MILLIAMPS
2500 V rms
2500 V rms
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH
2500 V rms
4000 V rms
INPUT DATA
AC - VOLTAGE:
DC - VOLTAGE:
MAXIMUM PULL-IN VOLTAGE:
MINIMUM DROP-OUT VOLTAGE:
INPUT IMPEDANCE:
NOT AVAILABLE
5 & 12 VDCVDC
4.0 & 9.3 VDC
2.0 VDC
16 MILLIAMPS MAX.
NOT AVAILABLE
3 TO 32 VDC
3 VDC
1 VDC
1500 Ω
- 30˚ C to + 80˚ C
- 40˚ C to + 100˚ C
- 30˚ C to + 80˚ C
- 40˚ C to + 100˚ C
- 30˚ C to + 80˚ C
- 40˚ C to + 120˚ C
16 mS TURN ON
60 mS TURN OFF
1/2 CYCLE
1/2 CYCLE
1/2 CYCLE
1010 Ω
TO-3
1010 Ω
P.C.
1010 Ω
TO-3
1010 Ω
PANEL
H
W
L
0.25 X 0.5 X .875
H
W
L
.700 X .860 X .860
.78 X 1.75 X 2.25
NOT AVAILABLE
5 & 12 DC
4.3 & 10.3 VDC)
1.5 VDC
15 MILLIAMPS MAX
NOT AVAILABLE
5 & 12 VDCVDC
4.0 & 9.3 VDC
2.0 VDC
15 MILLIAMPS MAX.
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
- 40˚ C to + 65˚ C
- 30˚ C to + 100˚ C
RESPONSE TIME
OPERATE MAX.:
RELEASE MAX:
GENERAL DATA
INSULATION RESISTANCE:
MOUNTING:
DIMENSIONS
H
W
L
.780 X .670 X .990
APPROVALS
H
W
C
L
US
PAGE 96
PAGE 94, 95
PAGE 102, 103
PAGE 101
PAGE104
PAGE NUMBER
PAGE 97,98
PAGE 99, 100
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 92
SPECIFICATIONS PAGE:
Magnecraft
Struthers-Dunn
SOLID STATE RELAYS & OPTO ISOLATORS
RELAY SERIES
6 (DSX)
6 (ASX)
DC Input - AC Output
AC Input - AC Output
L.E.D. "ON" LAMP
L.E.D. "ON" LAMP
301T
6 (DDX)
DC Input - DC Output
Opto-Isolators
NEW!
L.E.D.
L.E.D. INDICATES RELAY IS
IN THE OPERATE MODE.
FEATURES
OPTIONAL SAFETY COVER
FOR CLASS 6 AVAILABLE
SEE PAGE 88
DC CONTROLLED INPUT, AC CONTROLLED INPUT,
AC BACK TO BACK SCR
AC BACK TO BACK SCR
OUTPUT
OUTPUT
2.5 TO 75 AMP LOADS
2.5 TO 75 AMP LOADS
PHOTO ISOLATED, ZERO
VOLTAGE SWITCHING.
PHOTO ISOLATED, ZERO
VOLTAGE SWITCHING.
4000 V rms ISOLATION
INPUT TO OUTPUT.
4000 V rms ISOLATION
INPUTTO OUTPUT.
INTERNAL RC (SNUBBER)
NETWORK
INTERNAL RC (SNUBBER)
NETWORK
RFI SUPPRESSION.
RFI SUPPRESSION.
L.E.D. "ON" LAMP
DC CONTROLLED
INPUT, DC OUTPUT
AXIAL LEADS WITH
SHRINK TUBE CASE
12, 25 & 40 AMP LOADS AC & DC INPUTS AND
OUTPUTS
TRANSFORMER
HIGH INPUT & OUTPUT
ISOLATED, 2500 V rms ISOLATION
ISOLATION
INPUT TO OUTPUT.
TURN ON 10KΩ TURN
OFF 100KΩ.
RFI SUPPRESSION.
IDEAL FOR TRIGGERING
SCR'S & TRIACS OR
LOW VOLTAGE ON-OFF
SWITCH.
OUTPUT DATA
OUTPUT CONFIGURATION:
MAXIMUN ALLOWABLE
OUTPUT VOLTAGE & LOAD:
SPST-NO
SPST-NO
SPST-NO
SPST-NO
2.5 TO 75 AMPS
@
140 OR 280 VAC
2.5 TO 75 AMPS
@
140 OR 280 VAC
12, 25 & 40 AMPS
@
0 TO 200 VDC
0.2 WATTS
250VAC/VDC
SCR
SCR
TRANSISTOR
-
50 MILLIAMPS
50 MILLIAMPS
20 MILLIAMPS
-
2500 V rms
1000 V rms
120 VAC
2.0 TO 120 VDC
TO 10K Ω
100k Ω
-
OUTPUT DEVICE:
MINIMUM LOAD:
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH
4000 V rms
4000 V rms
INPUT DATA
AC - VOLTAGE:
DC - VOLTAGE:
MAXIMUM PULL-IN VOLTAGE:
MINIMUM DROP-OUT VOLTAGE:
INPUT IMPEDANCE:
NOT AVAILABLE
3 TO 32 VDC
3 VDC
1 VDC
1500 Ω
90 TO 280 VAC
80 TO 140 VDC
90 VAC/80VDC
10 VAC/10VDC
60K Ω
NOT AVAILABLE
3.5 TO 32 VDC
3.5 VDC
1 VDC
1000 Ω
- 30˚ C to + 80˚ C
- 40˚ C to + 120˚ C
- 30˚ C to + 80˚ C
- 40˚ C to + 120˚ C
- 0˚ C to + 80˚ C
- 40˚ C to + 120˚ C
- 40˚ C to + 60˚ C
1/2 CYCLE
10 mS
40 mS
100 uSec
1.0 mSec
-
1010 Ω
PANEL
1010 Ω
PANEL
1010 Ω
PANEL
109 Ω
AXIAL LEADS/SOLDER
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
RESPONSE TIME
OPERATE MAX.:
RELEASE MAX:
INSULATION RESISTANCE:
MOUNTING:
H
DIMENSIONS
W
L
0.78 X 1.75 X 2.25
APPROVALS
C
PAGE NUMBER
PAGE 93
US
PAGE 105
H
W
L
0.78 X 1.75 X 2.25
C
US
PAGE 106
H
W
L
0.78 X 1.75 X 2.25
C
H
W
L
0.45 X .438 X 1.4
US
PAGE 107
PAGE 108
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
APPLICATION DATA
CLASS
SSR
INTRODUCTION:
LOAD CONSIDERATIONS (cont.)
SOLID STATE RELAY (SSR) is a relay with isolated input and output,
whose functions are achieved by means of electronic components without
the use of moving parts as found in Electromechanical relays.
DC LOADS: All loads should be considered inductive and a Diode
should be placed across the load to absorb any inductive surge on
turnoff.
PRINCIPLE OF OPERATION:
Solid State Relays are similar to Electromechanical relays, in that both use
a control circuit and a separate circuit for switching the load. When voltage
is applied to the input of the SSR, the relay is energized by a light emitting
diode. The light from the diode is beamed into a light sensitive semiconductor which, in the case of zero voltage crossover relays, conditions the
control circuit to turn on the output solid state switch at the next zero voltage
crossover. In the case of nonzero voltage crossover relays, the output solid
state switch is turned on at the precise voltage occurring at the time.
Removal of the input power disables the control circuit and the solid state
switch is turned off when the load current passes through the zero point of
its cycle.
APPLICATIONS:
Solid State Relays are specially suitable in many applications.
Listed below are some typical applications.
Microprocessor-based Controls.
Computers and Computer Peripherals.
Process control Systems using PLCs
Temperature Control Systems.
Business Machines
Medical Equipment
Uninterrupted Power Supplies (UPS).
Communication
Traffic Signals, etc.
The Chart below indicates the areas in which SSR's (Solid State Relays) or
EMR (Electromechanical Relays) has better capabilities. (X) Indicates the
Better choice.
SSR
X
LAMP LOADS: Incandescent lamp loads, though basically
resistive, present some special problems. Because the resistance
of a cold tungsten filament is about five to ten percent of the
heated value, a large inrush current can occur. The period of the
inrush current can range from one half cycle to several cycles.,
depending on the thermal time constant of the filament. It is
essential to verify that this inrush current is within the surge
specifications of the SSR. Also check that the lamp rating of the
SSR is not exceeded. This is a UL rating based on the inrush of a
typical lamp. Because of the unusually low filament resistance at
the time of turn-on, a zero voltage turn-on characteristic is
particularly desirable with tungsten lamps.. It has been demonstrated that a zero voltage turn-on can extend the life of tungsten
lamps by limiting inrush current.
CAPACITIVE LOADS: Caution must be used with low impedance
capacitive loads to verify that the di/dt capabilities are not
exceeded. The di/dt of a discharged capacitive load with out
external limiting impedance can approach infinity. Zero voltage
turn-on is a particularly valuable means of limiting di/dt with
capacitive loads.
APPLICATION AND SELECTION CRITERIA FOR SOLID STATE
RELAYS:
Long Life
Temperature Cycling
Shock and Vibration Resistant
Immunity to False Operation due to Transients
Generation of RFI, EMI
Multipole
Multithrow (SPDT)
Size (includes Heat Sink) for Equivalent Load Handling
Contact Bounce
Arcless Switching
Acoustic Noise
Zero Voltage Switching
Ease Of Diagnosing Malfunction
IC Compatibility
Immunity to Humidity, Salt Spray & Dirt
RESISTIVE LOADS: Loads of constant value resistance are
probably the simplest application of SSR's. Proper attention to the
steady state current ratings and applied blocking voltage specifications normally will result in trouble-free operation.
EMR
X
X
X
X
X
X
X
X
X
X
X
X
X
X
LOAD CONSIDERATIONS
A major portion of application problems with SSR's result from operating
conditions which specific loads impose upon an SSR. The following types
of loads point out the potential problems that can occur with SSR's.
MOTORS: Specifically, motors frequently have severe inrush
currents during starting and can impose unusual voltages during
turnoff. The inrush currents connected to mechanical loads having
high starting torque or inertia should be carefully determined to
verify that they are within the surge capabilities of the SSR. A
current shunt and Oscilloscope should be used to examine the
duration of the inrush current. Motor starting may frequently
reoccur at short intervals and the affect of repetitive inrush currents
on the thermal operating point of an SSR must be considered.
Check the motor operating current and locked rotor current versus
the SSR motor rating. The possibility of abnormally stalled rotor
conditions which draw much higher than normal currents should be
considered. An extended stalled rotor condition may require an
oversized SSR or fuse protection. The generated EMF of certain
motors can require an SSR to have a blocking voltage greater than
might be expected from steady state line voltage. The voltage
applied to an SSR by a motor circuit during turnoff should be
examined with an oscilloscope to verify hat the applied voltages
are safely below the specified SSR blocking voltages. Otherwise
lock-on or erratic turnoff of the motor may occur. Some motor
circuits may require higher than normal blocking voltage, transient
limiting devices, or other techniques to control the voltage which
must be blocked by an SSR during deceleration or direction
reversal.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 94
CLASS
SSR
APPLICATION DATA
TRANSFORMERS
PROTECTING THE OUTPUT SWITCH
In controlling transformers, the characteristics of the secondary load should
be considered because it reflects the effective load on the SSR. Voltage
transients from secondary load circuits, similarly, are frequently transformed
and can be imposed on the SSR. Transformers present a special problem
in that, depending on the state of the transformer flux at the time of turnoff,
the transformer may saturate during the first half-cycle of subsequent
applied voltage. This saturation can impose a very large current (Commonly ten to one hundred times rated primary current) on the SSR and
exceed its half-cycle surge rating.
An SSR is a four layer semiconductor having 3 terminals:
Cathode, Anode and Gate. Normally it blocks current in both the
forward and reverse directions. The SCR is triggered on in the
forward direction by a small gate current. The SCR remains on
until load current decreases to a value less than necessary to
maintain the SCR in the on state. When switching AC, two SSR's
are connected in inverse parallel.
SSR's having random turn-on may have a better chance of survival than a
zero voltage turn-on device for they commonly require the transformer to
support only a portion of the first half-cycle of the voltage. On the other
hand, a random turn-on device will frequently close at the essentially zero
voltage point (start of the half-cycle) and then the SSR must sustain the
worst-case saturation current. A zero voltage turn-on device has the
advantage that it turns on in a known, predictable mode and will normally
immediately demonstrate (dependent on turnoff flux polarity) the worst-case
condition. The use of an oscilloscope is recommended to verify that the
half-cycle surge capability of the SSR is not exceeded. The severity of the
transformer saturation problem varies greatly, dependent on the magnetic
material of the transformer, saturated primary impedance, line impedance,
etc.
Both SCR's and Triacs are members of the thyristor family.
Therefore, we use this term to denote both devices. There are 4
ways to put a thyristor into a conducting mode. Only one method
is desirable and the other three are the source of most application
problems.
A safe rule of thumb in applying an SSR to a transformer primary is to select
an SSR having a half-cycle current surge rating (RMS) greater than the
maximum applied line voltage (RMS) divided by the transformer primary
resistance. The primary resistance is usually easily measured and can be
relied on as a minimum impedance limiting the first half-cycle of inrush
current. The presence of some residual flux plus the saturated reactance of
the primary will then further limit, in the worst case, the half-cycle surge
safely within the surge rating of the SSR.
D. Thermal Turn-on: Allowing the temperature of the thyristor to
go beyond the value sufficient to cause excessive leakage
current, causing turn-on and possible thermal runaway.
A Triac also has 3 terminals, like the SCR, it normally blocks
current in both directions; but may be triggered in either direction
by a small gate current
The 4 methods of Thyristor turn-on are A. Gate Turn-on: By injecting a controlled current into the gate
(the desired method).
B. Forward Breakover Turn-on: A voltage in excess of the
Breakover (or Peak Blocking) voltage across Thyristor.
C. DV/DT turn-on: A voltage which rises faster than the Thyristor
can tolerate, and still remain in the off state.
The last three methods can be protected against as follows. In
those situations where high peak voltage transients occur, effective
protection can be obtained by using metal oxide varistors (MOV).
The MOV is a bidirectional voltage sensitive device that has low
impedance when its design voltage threshold is exceeded.
HEAT SINKING
SELECTING THE PROPER SSR
NOMINAL LOAD CURRENT: Initially select a relay whose current rating
exceeds the normal load current. Using the load current vs. temperature
chart for that relay, check the actual current capacity at the ambient
temperature to which the relay will be subjected.
As an example, the chart below shows that a 25 ampere relay provided with
a suitable heat sink can safely carry a maximum of 17 amperes continuously at 40˚C ambient. Since heat degrades the output semiconductor
every effort should be made to keep the operating temperature of the SSR
as low as possible
25 Amp Styles
Load Current (Amps RMS)
40
Mounted on Heat Sink with 1˚c/w
thermal resistance.
(Sink to Ambient)
35
30
25
20
15
6" x 6" x 1/8"
Aluminum
Plate
10
5
Free Air Mounting
0
20
40
60
80
100
Max. Ambient Temperature (˚C)
PAGE 95
It is important to select the right size heat sink for your applications.
SSR's will typically generate 1.2 watts per amp of load current.
The maximum junction temperature of the output device is 115˚C.
The total wattage is divided by the thermal resistance to get the
temperature difference between the output device junction and the
ambient temperature. For example a 25 Amp SSR with a 20 Amp
load applied dissipates 24 watts when mounted on a aluminum
plate 6" X 6" X 1/8" with thermal grease applied between the SSR
base and aluminum plate. This combination produces a output
junction temperature rise of 24 watts. 24W times (1˚ c/w relay +
1˚ c/w (heat sink) = a operating temperature of 48˚C.
FUSING
THE SSR has a I2T rating which is a measure of the amount of
energy it can safely handle without damage. The I2T rating of the
fuse is a measure of the amount of energy the fuse will pass to the
SSR. To protect the SSR, the I2T of the Fuse should be less than
that of the SSR. An SSR exposed to a surge greater than its nonrepetitive rating will normally fail as a shorted unit.
EXPRESSIONS USED IN SPECIFICATIONS
dv
dt
equals the maximum permissable rate of change
of voltage in volts/microseconds
V=
I=
(PF)=
f=
L=
C=
R 1 & R2 =
Line Voltage
Load Current
Load Power Factor
Line Frequency
Inductance in Henrys
Capacitance in microfarads
Resistance in Ohms
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
SPECIFICATIONS CLASS 226, 230, 231
TERMINALS PINS MATE WITH STANDARD
PUSH-ON CONNECTORS. P.C. TERMINAL
STYLE ALSO AVAILABLE.
SSR
FLANGED HEAT SINK STYLE
WITH 3/16" SPADE STYLE
TERMINALS FOR SOLDER OR
Q.C. CONNECTORS
P.C. BOARD MOUNTABLE
1.5 AMP RATING
230E
226
P.C. BOARD MOUNTABLE
WITH HEAT SINK
3.0AMP RATING
231
230T
MOUNTABLE ON STANDARD
TO-3 TRANSISTOR HEAT SINK
MOUNTABLE ON STANDARD
TO-3 TRANSISTOR HEAT SINK
R
UL Recognized
File No. E52197
Maximum Average On-State Power
Dissipation (Watts)
CLASS 230/231
TYPICAL DERATING CURVES
CLASS 230E, 230T, 231D
4.0
AMPERES
3.0 Amp (230T)
6.7˚ c/w HEAT SINK
3.0
2.0
1.5 Amp (230E)
1.0
NO HEAT SINK
0
25
40
55
70
80
OPERATING TEMPERATURE (˚C)
14
12
10
8
6
4
2
0
0
1
2
3
4
5
6
RMS On-State Current (AMPERES)
CLASS 226 CURRENT RATINGS
6
5
Thermolloy
4 #6103 Base
14˚C/Watt
3
Integral
2 Heat sink
1
0
Wakefield
#6908
6.7˚C/Watt
Thermal Joint
compound used.
20 30 40 50
Wakefield
#401A
2˚C/Watt
60
70
AMBIENT TEMPERATURE (˚C)
SURGE CURRENT RATINGS
100
80
60
@25˚C 60 Hz
40
20
10
010
.10
1.0
10
SURGE CURRENT DURATION
(SECONDS)
RMS ON STATE CURRENT (AMPERES)
CURRENT AMPS (AC)
7
CLASS 230/231
PEAK SURGE CURRENT (NON-REPETITIVE)
RMS AMPERES
OUTPUT CURRENT RATINGS
VS
AMBIENT TEMPERATURE
400
100
40
1.5 Amp series should not be
operated above 1.5 Amps at
duty cycle greater than 25%
10
4
1
0.4
TJ = 105˚C
0.1
0
1
2
3
Maximum RMS On-State Voltage
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 96
CLASS
226
MINIATURE SOLID STATE RELAY
CLASS 226
RANDOM VOLTAGE TURN ON
UP TO 7 AMPS
SPST—NO
DC INPUTS
AC OUTPUTS
COMPATIBLE WITH TTL GATES.
PRINTED CIRCUIT AND PUSH-ON
TERMINAL PIN VERSIONS.
UL Recognized
File No. E52197
R
Dimensions shown in Inch and (Millimeters).
1.50
(38.5)
.670
(17.0)
INPUT
.4.92
(12.5)
.155
(3.9)
1.18
(30.2)
.200
(5.1)
OUTPUT
.4.92
(12.5)
.755
(19.1) .600 Max
(15.2)
.300
(7.5)
+ 5V
Supply
.050
(38.1)
FIG. "A"
.156 Dia.
(3.8) 2 Places
.340
(8.6)
.940
(23.4)
.600 Max
(15.2)
Series 226 Schematic typical TTL input Connections
TOP VIEW
+ 5V
Supply
226R
Standard
TTL Gate
.990 Typ.
(25.1)
.062 Dia.
(1.6) Typ. all Pins
FIG. "B"
.050
(1.3)
Load
Input
5 VDC
15 mA
Output
120 or 240 VAC
up to 7 Amps
R1
MAX. RNS LOAD CURRENT (AMPS)
THERMAL DERATING CURVE
Y
8
6
4
2
Z
0
10
20
30
40
50
60
70
80
AMBIENT TEMPERATURE (˚C)
Y= WITHOUT EXTERNAL HEAT SINK.
Z= WITH HEAT SINK HAVING 0 SA= 3.2˚C/W.
INPUT CHARACTERISTICS
Input Impedance
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
OUTPUT CHARACTERISTICS
Rated Load Current (Amps rms)
Input Current (Typ.) 5VDC
Maximum off State Leakage current ID (RMS)
Non-Repetitive Surge Current one Cycle (Amps peak)
Maximum rms Overload current for 1 second
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
PAGE 97
5 or 12 VDC
5V= 240 Ohms / 12V=820 Ohms Typ.
Turn-on 10 mS max., Turn-off 60 mS max.
100V/uSec blocking 4V/uSec commutating
120 VAC or 240 VAC
7 Amperes
10 Ma
0.1 mA @ 25˚C
100 Amperes
18 Amperes
24 Amperes
3.4˚c/w
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
MINIATURE SOLID STATE RELAY
226
SPECIFICATIONS CLASS 226
INPUT CHARACTERISTICS
Reverse Polarity Protected:
Input Filtered for transients less than one millisecond.:
OUTPUT CHARACTERISTICS
Rated Load Current: IT (RMS):
Line Voltage Range (VAC):
Maximum output voltage (VAC):
Non-Repetitive Peak Voltage VDSM (Blocking Voltage):
Minimum Load Current IT MIN (RMS) to maintain “On”:
Maximum Off State Leakage current ID (RMS):
Maximum RMS On-State Voltage VT (RMS) Maximum
Voltage drop across relay output @ rated current:
Minimum off-state dv/dt:
MISCELLANEOUS
Contact configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance RISO @ 500VDC:
Operating temperature Range:
Storage temperature Range:
Life:
Mounting:
Weight:
NO
NO
7 Amps
W226R & RE-7 Models: 120 VAC,
W226R & RE-8 Models: 240 VAC
W226R & RE-7 Models: 260 VAC,
W226R & RE-8 Models: 380 VAC
W226R & RE-7 Models: 400 VAC,
W226R & RE-8 Models: 700 VAC
50 mA
0.1 mA @ 25˚C, 1.0 mA @ 65˚C
W226R & RE-7 Models: 1.8V, W226R & RE-8 Models: 3.6 V
100V/uSec blocking 4V/uSec commutating
SPST-NO
2500 VAC
1010 Ω
-30°C to +80°C
-40°C to +100°C
Greater than 100 million operations
TO-3
0.45 oz. (13 g)
PUSH-0N TERMINAL RECEPTACLES
MOLEX
FOR 18-22 AWG 02-06-1103
FOR 24-30
02-06-1132
WINCHESTER
156-10185
156-10245
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range)
PART
NUMBERS
FIGURE
INPUT
VOLTAGE
MIN.
MAX.
PULL-IN DROPOUT
VOLTAGE VOLTAGE
NOMINAL
VOLTAGE
MAX.
VOLTAGE
OUTPUT
CURRENT
4.3 VDC
10.3 VDC
4.3 VDC
10.3 VDC
1.4 VDC
2.5 VDC
1.4 VDC
2.5 VDC
120 VAC
120 VAC
240 VAC
240 VAC
260 VAC
260 VAC
380 VAC
380 VAC
7 AMPS
7 AMPS
7 AMPS
7 AMPS
4.3 VDC
10.3 VDC
4.3 VDC
10.3 VDC
1.4 VDC
2.5 VDC
1.4 VDC
2.5 VDC
120 VAC
120 VAC
240 VAC
240 VAC
260 VAC
260 VAC
380 VAC
380 VAC
7AMPS
7AMPS
7 AMPS
7AMPS
PUSH ON TERMINALS
W226R-7-5A1
W226R-7-12A1
W226R-8-5A1
W226R-8-12A1
A
A
A
A
5 VDC
12 VDC
5 VDC
12 VDC
PRINTED CIRCUIT TERMINALS
W226RE-7-5A1
W226RE-7-12A1
W226RE-8-5A1
W226RE-8-12A1
B
B
B
B
5 VDC
12 VDC
5 VDC
12 VDC
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the
SSR mounting base and mounting surface of suitable heat sink).
Part Numbers shown also available thru Stocking Distribution.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 98
CLASS
MINIATURE P.C. SOLID STATE RELAY
230
CLASS 230
1.5 & 3 AMP SWITCHING
SPST—NO
DC INPUTS, AC OUTPUTS
ZERO VOLTAGE SWITCHING.
CLASS 230 E
1.5 AMP RATED
Dimensions Shown in Inches & (Millimeter)
0.296
0.875
(7.5)
(22.3)
0.50
(12.7)
230E
10
.020
(.50)
0.20
(5.1)
0.6
(15.2)
0.30
(7.6)
+16
Bottom
-1
8
0.30 0.50
(7.62) (12.7)
0.7
(17.7)
CLASS 230T
4.0 AMP RATED
FIGURE A
.030
(.76)
0.335
(8.5)
230T
1.23
(31.4)
10
+16
DC
AC
Input
Output
8 Bottom -1
.200
(5.1)
.400
(10.1)
0.150 Dia.
(3.8)
FIGURE B
UL Recognized
File No. E52197
INPUT CHARACTERISTICS
Input Impedance (Current @ Nominal Voltage)
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
OUTPUT CHARACTERISTICS
Rated Load Current (Amps rms)
Maxium off State Leakage current ID (RMS)
Non-Repetitive Surge Current one Cycle (Amps peak)
Maximum rms Overload current for 1 second
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
PAGE 99
Terminals
.025, (6.3)
Typical
R
PIN 16 = + DC INPUT
PIN 1 = DC INPUT
PIN 8 = AC LOAD OUTPUT
PIN 10 = AC LOAD OUTPUT
5 or 12 VDC
13mA typical / 16 mA max.
1/2 Cycle
200V/uSec blocking 4V/uSec commutating
120 VAC or 240 VAC
230E 1.5 Amps, 230T 3.0 Amps
1 mA max.
20 Amperes
5 Amperes
4.5 Amperes
230T 8˚c/w
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
MINIATURE P.C. SOLID STATE RELAY
230
SPECIFICATIONS CLASS 230
INPUT CHARACTERISTICS
Reverse Polarity Protected:
Input Filtered for transients less than one millisecond.:
OUTPUT CHARACTERISTICS
Rated Load Current: IT (RMS):
Line Voltage Range (VAC):
Maximum output voltage (VAC):
Non-Repetitive Peak Voltage VDSM (Blocking Voltage):
Minimum Load Current IT MIN (RMS) to maintain “On”:
Maximum Off State Leakage current ID (RMS):
Maximum RMS On-State Voltage VT (RMS)
@ rated current:
Maximum rate of rise off-state voltage dv/dt:
MISCELLANEOUS
Contact configuration:
Dielectric Strength VISO (Input-Output Isolation):
Insulation Resistance RISO @ 500VDC:
Operating temperature Range:
Storage temperature Range:
Life:
Mounting
Weight:
NO
NO
W230E Models: 1.5 Amps, W230T Models: 3 Amps
120 VAC or 240 VAC
140 VAC or 280 VAC
120V Models: 400 VAC, 240V Models: 500 VAC
20 mA @ 25˚C
1.0 mA max.
1.7 V
200V/uSec
SPST-NO
2500 VAC
1010 Ω
-30°C to +80°C
-40°C to +100°C
Greater than 100 million operations
P.C.
0.37 oz. (10.6 g)
PUSH-0N TERMINAL RECEPTACLES
MOLEX
FOR 18-22 AWG 02-06-1103
FOR 24-30
02-06-1132
WINCHESTER
156-10185
156-10245
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE
PART
NUMBERS
FIGURE
INPUT
VOLTAGE
MIN.
MAX.
PULL-IN DROPOUT
VOLTAGE VOLTAGE
NOMINAL
VOLTAGE
MAX.
VOLTAGE
OUTPUT
CURRENT
CP CLARE/ THETA-J
2.0 VDC
2.0 VDC
2.0 VDC
2.0 VDC
120 VAC
240 VAC
120 VAC
240 VAC
140 VAC
280 VAC
140 VAC
280 VAC
1.5 AMPS
1.5 AMPS
1.5 AMPS
1.5 AMPS
0FA1202
0FA2402
0FB1202
0FB2402
120 VAC
240 VAC
120 VAC
240 VAC
140 VAC
280 VAC
140 VAC
280VAC
3 AMPS
3 AMPS
3 AMPS
3 AMPS
PRINTED CIRCUIT TERMINALS
W230E-1-5
W230E-2-5
W230E-1-12
W230E-2-12
A
A
A
A
5 VDC
5 VDC
12 VDC
12 VDC
4.0 VDC
4.0 VDC
9.3 VDC
9.3 VDC
PRINTED CIRCUIT TERMINALS WITH HEAT SINK
W230T-3-5
W230T-4-5
W230T-3-12
W230T-4-12
B
B
B
B
5 VDC
5 VDC
12 VDC
12 VDC
4.0 VDC
4.0 VDC
9.3 VDC
9.3 VDC
2.0 VDC
2.0 VDC
2.0 VDC
2.0 VDC
0FA1205D
0FA2405D
0FB1205D
0FB2405D
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the
SSR mounting base and mounting surface of suitable heat sink).
Part Numbers shown also available thru Stocking Distribution.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 100
CLASS
231
MINIATURE SOLID STATE RELAY
CLASS 231
4 AMPS
SPST—NO
DC INPUTS,
AC OUTPUTS
ZERO VOLTAGE
SWITCHING.
.340 Max
(8.6)
.600 Max
(15.24)
,048 Max
(1.2)
1.40
(35.5)
1.19
(30.2)
+ 3
INPUT
LOAD
1 AC
.860
(21.8)
Top View
2 AC
.078 R
(1.98)
.250
(6.3)
.250 x .032 Typ.
(6.3) x .81
- 4
.595
(15.1)
.860
(21.8)
.187 x .032 Typ.
(4.7) x .81
Dimensions Shown in Inches & (Millimeters)
UL Recognized
File No. E52197
INPUT CHARACTERISTICS
5 or 12 VDC
Input Impedance (Current @ Nominal Voltage)
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
13mA typical / 16 mA max.
1/2 Cycle
200V/uSec blocking 10V/uSec commutating
120 VAC or 240 VAC
OUTPUT CHARACTERISTICS
Rated Load Current (Amps rms)
Maximum off State Leakage current ID (RMS)
Non-Repetitive Surge Current one Cycle (Amps peak)
Maximum rms Overload current for 1 second
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
4 Amperes
1 mA @ 25˚C
20 Amperes
5 Amperes
4.5 Amperes
6˚c/w
THE W231 SSR HAS THE SAME ELECTRICAL SPECIFICATIONS AS LISTED FOR THE W230 SSR's. THE EXCEPTION IS
THE CLASS W231 IS RATED AT 4.0 AMPS.
QUICK DISCONNECT TERMINALS
WITH .060 DIA. HOLES
TERMINALS 1 & 2, .250 X .032 BRASS
TERMINALS 3 & 4, .187 X .032 BRASS
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range) CROSS REFERENCE
PART
NUMBERS
INPUT
VOLTAGE
MIN.
MAX.
PULL-IN DROPOUT
VOLTAGE VOLTAGE
NOMINAL
VOLTAGE
MAX.
VOLTAGE
OUTPUT
CURRENT
2.0 VDC
2.0 VDC
2.0 VDC
2.0 VDC
120 VAC
240 VAC
120 VAC
240 VAC
140 VAC
280 VAC
140 VAC
280 VAC
4 AMPS
4 AMPS
4 AMPS
4 AMPS
CP CLARE/ THETA-J
FLANGE MOUNT
W231D-3-5
W231D-4-5
W231D-3-12
W231D-4-12
5 VDC
5 VDC
12 VDC
12 VDC
4.0 VDC
4.0 VDC
9.3 VDC
9.3 VDC
0FA1205
0FA2405
0FB1205
0FB2405
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the
SSR mounting base and mounting surface of suitable heat sink).
Mounting: TO-3 Style.
Weight: .57oz. (16.2 grams).
Part Numbers shown also available thru Stocking Distribution.
PAGE 101
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
SPECIFICATIONS SOLID STATE RELAY
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
UL Recognized
File No. E52197
NEW!
HI
DV GH
RA /DT
TI
NG
L.E.D. "ON" LAMP
UT
S
INP MINAL
R
TE
CL
AS
S6
Dimensions shown in Inch and (Millimeter).
2.25
(57.2)
1.87
(47.5)
RU
CO GG
NS ED
TR
UC
T
IO
N
1.75
(44.45)
INPUT
T
S
PU NAL
T
I
OU RM
TE
0.32
(8.1)
4 OUTPUT 3
2
INPUT
RED
L.E.D.
1
1.00
1.75 (25.4)
(44.5)
SS
R
OUTLINE DIMENSIONS
0.19
0.37 (4.8)
(9.4)
6
1.10
(27.9)
.49 Typ.
(12.5)
.175 Dia. (4.44)
(2 Holes)
Clamping Plate
4 Places
(Not used on models .996 high)
.215
(5.46)
.265 max.
(6.73)
OUTPUT
SEE CHART
INPUT & OUTPUT SCREW SIZE
(Shown in Millimeters)
UP TO 40 AMP
INPUT
3.5 mm
ABOVE 40 AMP
3.5 mm
.996 max. (25.3) for 25 & 40 amp DDX models & for 75
Amp DSX & ASX models.
.800 max (20.32) for models ASX, DSX & DTX models up
to 40 Amps & DDX 12 Amp models.
OUTPUT
4 mm
6 mm
SURGE: OUTPUT 120 & 240 VAC
CLASS 6
TYPICAL INPUT CURRENT
Input Current (mA)
35
30
25
20
DC INPUT
15
10
AC INPUT
5
0
10
20
30
100 200
300
Input Voltage (Volts)
DC Input Models
AC Input Models
Non- Repetitive Surge RMS Amps
1000
40
500
200
50
75 Amps
40 Amps
25 Amps
20
10 Amps
100
10
5
2.5 Amps
2
1
.01 .02 .05 0.1 0.2 0.5 1.0 2.0 5.0 10.0
Time in Seconds
Surge: Curves represent relay tolerance to load
surge currents as to magnitude and duration of
both repetitive and non-repetitive surge currents.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 102
CLASS
GENERAL SPECIFICATIONS
6
SPECIFICATIONS CLASS 6 SOLID STATE RELAYS
INPUT CHARACTERISTICS
Input voltage range:
Power indicator:
Reverse Polarity Protected:
Input Filtered for transients less than one millisecond.:
Control current:
OUTPUT CHARACTERISTICS
Contact rating:
Line Voltage Range (VAC)
Maximum output voltage (VAC):
Non-Repetitive Peak Voltage VDSM (Blocking Voltage)
Minimum Load Current IT MIN (RMS) to maintain “On”
Maximum Off State Leakage current ID (RMS)
Maximum RMS On-State Voltage VT (RMS) Maximum
Voltage drop across relay output @ rated current:
Minimum off-state dv/dt:
MISCELLANEOUS CHARACTERISTICS
Contact configuration:
Dielectric Strength VISO (Input-Output Isolation)
Insulation Resistance RISO @ 500VDC
Operating temperature Range
Storage temperature Range
Life:
Weight
3-32 VDC, 90-280 VAC or 0 to 200VDC
L.E.D. Lamp
YES: DC Input with AC output styles only.
No
12 mA @ 5Vdc, 10 mA @ 120 Vac
2 Amps to 75 Amps
W61 Models: 24-120VAC, W62 Models: 40-240 VAC
W61: 140VAC, W62: 280 VAC
W61: 300VAC , W62: 600VAC
Up to 40 amp Models: 50 ma, 50 to 75 Amp models: 250mA
Up to 40 amp Models: 8 mA, 50 to 75 Amp models: 10mA
Up to 40 amp Models: 1.6V, 50 to 75 Amp models: 1.8 V
500v/usec
SPST-NO (1 FORM A)
4000 VAC, DDX models 2500 VAC
1010 Ω
-40°C to +80°C
-40°C to +100°C
Greater than 100 million operations
2.5 to 50 AMP Models: 4 oz. (110 g)
75 AMP Models: 6.8 oz. (192 g)
25 AMP & 40 AMP, DDX Models: 4.76 oz. (135 g)
Thermal Derating Curve & Load Characteristics
3
2
Free Air Mounting
0
20
40
60
80
100
Max. Ambient Temperature (˚C)
6" x 6" x 1/8" Aluminum Plate
14
12
Heat Sink
with
1˚c/w
thermal
resistance.
10
8
6
4
25 Amp Styles
40
Load Current (Amps RMS)
6" x 6" x 1/8" Aluminum Plate
1
10 Amp Styles
16
Load Current (Amps RMS)
Load Current (Amps RMS)
2.5 Amp Style
Free Air Mounting
2
35
30
Mounted on Heat Sink with 1˚c/w
thermal resistance.
(Sink to Ambient)
25
20
15
10
5
6" x 6" x 1/8"
Aluminum
Plate
Free Air Mounting
0
20
40
60
80
100
Max. Ambient Temperature (˚C)
0
20
40
60
80
100
Max. Ambient Temperature (˚C)
80
-90
Mounted on Heat Sink with 1˚c/w
thermal resistance.
70
50
6" x 6" x 1/8"
Aluminum Plate
40
30
20
10
Free Air Mounting
0
20
40
60
80
100
Max. Ambient Temperature (˚C)
Load Current (Amps RMS)
Load Current (Amps RMS)
90
60
6" x 6" x 1/8"
Aluminum Plate
45
-95
-100
40
30
-105
20
-110
10
0
0 10 20 30 40 50 60 70 80
Max. Ambient Temperature (˚C)
Max. Allowable Case temperature (˚c)
75 Amp Styles
75
40 & 50 Amp Styles
All current ratings in the following pages are based on use of suitable thermally conductive compound (e.g. silicone grease
between the SSR mounting base and mounting surface of suitable heat sink).
PAGE 103
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
DC CONTROLLED INPUT TRIAC OUTPUT SSR
High Transient Capability—Single output
features back to back SCR’s and internally
mounted RC (snubber) network for high dv/dt
applications.
Photo-Isolated, Zero Voltage Switching—
Optically coupled for 4000 VAC isolation
between input and output and RFI suppression.
6
CLASS 6
DC CONTROLLED INPUT
WITH L.E.D. "ON" LAMP.
AC TRIAC OUTPUT.
NEW!
L.E.D. "ON" LAMP
UL Recognized
File No. E52197
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
3 to 32 VDC
INPUT CHARACTERISTICS
Input Impedance
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
1500 ohms minimum
1/2 Cycle Max.
200 Volts per microsecond
120 or 240 VAC
OUTPUT CHARACTERISTICS
Rated Load Current (Amps rms)
U/L Incandescent Lamp Ampere Ratings
U/L Motor Load Ampere Ratings
Non-Repetitive Surge Current one Cycle (Amps peak)
Maximum rms Overload current for 1 second
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
10.0
7.0
4.5
100
24
42
2.1
SEE CLASS 6 GENERAL SPECIFICATIONS
PART
NUMBERS
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range)
CROSS REFERENCE TO:
NOMINAL
MAX.
MAX.
POTTER &
VOLTAGE VOLTAGE CURRENT
CRYDOM
IDEC
BRUMFIELD
RANGE
RATING
MIN.
CONTROL MAX.
VOLTAGE PULL-IN DROPOUT
RANGE VOLTAGE VOLTAGE
W6110DTX-1 3-32 VDC 3 VDC
1 VDC
24-120AC 140 VAC
10 AMPS
TD1210
-
SSRT120D10
W6210DTX-1 3-32 VDC 3 VDC
1 VDC
48-240AC 280 VAC
10 AMPS
TD2410
-
SSRT240D10
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting
surface of suitable heat sink).
Part Numbers shown also available thru stocking distribution.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 104
CLASS
DC CONTROLLED SOLID STATE RELAY
6
CLASS 6
High Transient Capability—Single output features back to back SCR’s an
internal mounted RC (snubber) network
for high dv/dt applications.
Photo-Isolated, Zero Voltage Switching—
Optically coupled for 4000 VAC isolation
between input, output and RFI suppression.
DC CONTROLLED INPUT
WITH L.E.D. "ON" LAMP.
AC SCR OUTPUTS UP
TO 75 AMPS.
NEW!
L.E.D. "ON" LAMP
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
UL Recognized
File No. E52197
INPUT CHARACTERISTICS
3 to 32 VDC
Input Impedance
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
200
400 ohms @ 3 VDC Typical
1/2 Cycle Max.
500 Volts per microsecond
120 VAC or 240 VAC
OUTPUT CHARACTERISTICS
Rated Load Current (Amps rms)
U/L Incandescent Lamp Ampere Ratings
U/L Motor Load Ampere Ratings
Non-Repetitive Surge Current one Cycle (Amps peak)
Maximum rms Overload current for 1 second
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
Minimum Load current, (mA).
2.5
2.0
1.0
100
5
72
8.5
50
10
8.0
4.5
100
24
72
1.78
50
25
16
8
250
40
800
1.02
120
40
30
14
350
80
1250
0.63
250
50
30
14
350
100
1250
0.63
250
75
39
25
1150
150
5000
0.63
250
SEE CLASS 6 GENERAL SPECIFICATIONS
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range)
PART
NUMBERS
MIN.
CONTROL MAX.
VOLTAGE PULL-IN DROPOUT
RANGE VOLTAGE VOLTAGE
NOMINAL
VOLTAGE
RANGE
MAX.
VOLTAGE
NAX.
CURRENT
RATING
CROSS REFERENCE TO:
CRYDOM
IDEC
POTTER &
BRUMFIELD
W6102DSX-1
W6110DSX-1
W6125DSX-1
W6140DSX-1
W6150DSX-1
W6175DSX-1
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
24-120AC
24-120AC
24-120AC
24-120AC
24-120AC
24-120AC
140 VAC
140 VAC
140 VAC
140 VAC
140VAC
140VAC
2.5 AMPS
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
D1202
D1210
D1225
D1240
EOM1DA22-4-32
RSSD-10A EOM1DA42-4-32
RSSD-25A
SSR240D25
RSSD-40A
RSSD-50A
SSR240D50
RSSD-75A
SSR240D80
W6202DSX-1
W6210DSX-1
W6225DSX-1
W6240DSX-1
W6250DSX-1
W6275DSX-1
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3-32 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
3 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
1 VDC
48-240AC
48-240AC
48-240AC
48-240AC
48-240AC
48-240AC
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
280 VAC
2.5 AMPS
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
D2402
D2410
D2425
D2440
D2450
D2475
RSSD-10A EOM1DA44-4-32
RSSD-25A
SSR240D25
RSSD-40A
RSSD-50A
SSR240D50
RSSD-75A
SSR240D80
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base and mounting
surface of suitable heat sink).
Part Numbers shown also available thru stocking distribution.
PAGE 105
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
AC CONTROLLED SOLID STATE RELAY
High Transient Capability—Single output
features back to back SCR’s and internally
mounted RC (snubber) network for high dv/dt
applications.
Photo-Isolated, Zero Voltage Switching—
Optically coupled for 4000 VAC isolation
between input and output and RFI suppression.
6
CLASS 6
AC CONTROLLED INPUT
WITH L.E.D. "ON LAMP"
AC SCR OUTPUT.
NEW!
L.E.D. "ON" LAMP
UL Recognized
File No. E52197
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
INPUT CHARACTERISTICS
Input Impedance
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
90 to 280 VAC or 80 to 140 VDC
13K ohms @ 120VAC typical
10 mS Turn ON, 40 mS Turn OFF.
200
500 Volts per microsecond
120 VAC or 240 VAC
OUTPUT CHARACTERISTICS
Rated Load Current (Amps rms)
U/L Incandescent Lamp Ampere Ratings
U/L Motor Load Ampere Ratings
Non-Repetitive Surge Current one Cycle surge (Amps peak)
Maximum rms Overload current for 1 second
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case (TJ , Max.= 1150C) 0c/w
Minimum Load current, (mA):
2.5
2.0
1.0
100
5
72
8.5
50
10
8.0
4.5
100
24
72
1.48
50
25
16
8.0
250
40
800
1.02
120
40
50
30
30
14
14
350
350
80
100
1250 1250
0.63 0.63
120
120
75
39
25
1150
150
5000
0.63
120
SEE CLASS 6 GENERAL SPECIFICATIONS
INPUT (Over Operating Temperature Range)
PART
NUMBERS
CONTROL
VOLTAGE
RANGE
MAX.
PULL-IN
VOLTAGE
0UTPUT (Over Operating Temperature Range)
CROSS REFERENCE TO:
MIN.
DROPOUT
VOLTAGE
NOMINAL
MAX.
MAX.
VOLTAGE VOLTAGE CURRENT CRYDOM
RANGE
RATING
IDEC
POTTER &
BRUMFIELD
W6110ASX-1
W6125ASX-1
W6140ASX-1
W6150ASX-1
W6175ASX-1
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
24-120AC
24-120AC
24-120AC
24-120AC
24-120AC
140 VAC
140 VAC
140 VAC
140 VAC
140VAC
10 AMPS
25 AMPS
40 AMPS
50 AMPS
75 AMPS
A1210
A1225
A1240
A1250
A1275
RSSAN-10A
RSSAN-25A
RSSAN-40A
RSSAN-50A
RSSAN-75A
SSR240A25
SSR240A50
SSR240A80
W6202ASX-1
W6210ASX-1
W6225ASX-1
W6240ASX-1
W6250ASX-1
W6275ASX-1
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 -280 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
90 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
10 VAC
48-240AC
48-240AC
48-240AC
48-240AC
48-240AC
48-240AC
280 VAC 2.5 AMPS
280 VAC 10 AMPS
280 VAC 25 AMPS
280 VAC 40 AMPS
280 VAC 50 AMPS
280 VAC 75 AMPS
A2402
A2410
A2425
A2440
A2450
A2475
RSSAN-10A
RSSAN-25A
RSSAN-40A
RSSAN-50A
RSSAN-75A
SSR240A25
SSR240A50
SSR240A80
Part Numbers shown also available thru stocking distribution.
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR mounting base
and mounting surface of suitable heat sink).
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 106
CLASS
DC CONTROLLED INPUT DC OUTPUT
6
CLASS 6
Transformer-Isolated, for 2500 VAC isolation
between input and output and RFI suppression.
DC CONTROLLED INPUT
DC OUTPUT
NEW!
L.E.D. "ON" LAMP
UL Recognized
File No. E52197
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
INPUT CHARACTERISTICS
3.5 to 32 VDC
Input Impedance
Response Time
Maximum Rate of Rise of Off State Voltage dv/dt
1000 ohms minimum
100 uS: On, 1.0 mS: Off 600 uS: On, 2.6 mS Off
200 Volts per microsecond
0
OUTPUT CHARACTERISTICS
to 200 VDC
12.0
20 mA
27
17
2.83
2.1
1.06
12 mA
Rated Load Current (Amps rms)
Minimum Load current to maintain "On"
Non-Repetitive Surge Current (1 cycle surge)
FW rectified current repetitive 60 Hz Amps peak
Voltage drop across output @ rated current
Max I2T For Fusing ( t= 8-3ms) A2 sec
Thermal Resistance Junction To Case 0c/w
Max. off state leakage current:
25
20 mA
50
2.83
2.1
1.06
12 mA
40
20 mA
90
2.83
2.1
1.06
12 mA
SEE COMPLETE SPECIFICATIONS PAGES 83 & 84
PART
NUMBERS
INPUT (Over Operating Temperature Range) 0UTPUT (Over Operating Temperature Range)
MAX.
MIN.
NOMINAL
MAX.
PULL-IN DROPOUT
VOLTAGE
CURRENT
VOLTAGE VOLTAGE
RANGE
RATING
CONTROL
VOLTAGE
RANGE
CROSS REFERENCE
CRYDOM
W6212DDX-1
3.5 - 32 VDC 3.5 VDC
1 VDC
0 -200 VDC
12 AMPS
D2D12
W6225DDX-1
3.5 - 32 VDC 3.5 VDC
1 VDC
0 -200 VDC
25 AMPS
D1D20*
W6240DDX-1
3.5 - 32 VDC 3.5 VDC
1 VDC
0 -200 VDC
40 AMPS
D1D40*
Part Numbers shown also available thru stocking distribution.
All current ratings are based on use of suitable thermally conductive compound (e.g. silicone grease between the SSR
mounting base and mounting surface of suitable heat sink).
* Crydom relays only rated at 0 - 100 VDC.
PAGE 107
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CLASS
301T OPTO-ISOLATOR
OPTICAL COUPLING PROVIDES HIGH
INPUT TO OUTPUT ISOLATION.
CAN BE USED AS AN ON/OFF
SWITCH OR LOW VOLTAGE
CONTROLLED RESISTOR. IDEAL
FOR TRIGGERING SCR'S AND TRIACS.
SSR
301T OPTO-ISOLATOR
0.2 WATT OUTPUT
VAC OR VDC OUTPUTS
SPECIFICATIONS 301T
OUTLINE DIMENSIONS
CONTACTS
Output Voltage Max:.
± 250 VDC or VAC Peak
INSULATION RESISTANCE
Dielectric Strength
Across Open Contacts:
Insulation Resistance:
1000 V rms Between all insulated Points
9
10
Ohms
L
Shrink Tube Case
0.04 oz (1.1 g)
+
If DC
L
INPUT
W301T1-2A1
W301T1-2B1
W301T1-12B1
W301T1-120A1
.45 Max
(11.4)
SCHEMATIC
VOLTAGE
OUTPUT
CURRENT
ON
(mA)
RESISTANCE
(Ohms max.)
40
25
24
1.3
1.7 VDC
LED
2.0 VDC
LED
INCAND. 12 VDC/AC
120 VDC/AC
NEON
PC
Lamp
UL Recognized
File No. E104675
R
LAMP
TYPE
1.00 ± .125
(25.4 ± 3.17)
# 26 AWG
Typical
NOT RECOMENDED FOR WAVE OR DIP
SOLDERING. ALSO MAY BE AFFECTED
BY CLEANING SOLVENTS
PART
NUMBERS
1.40 Max.
(35.6)
1.00 ± .125
(25.4 ± 3.17)
ENVIRONMENTAL CAPABILITIES
Ambient Temperature
Operating:
-40˚C to + 60˚C
Miscellaneous
Weight:
.438
(11.1)
PC
2000Ω
1000Ω
400Ω
1200Ω
RESPONSE TIME
POWER
DISSIPATION
Per pole (mW)
TURN-ON
TO 10KΩ
(mS max.)
TURN-OFF
TO 100KΩ
(mS max.)
200
200
200
200
10
5
150
35
50
100
300
100
Add 47KΩ Ohm external series resistor to limit current.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
OUTLINE DIMENSIONS
1.04 Max
(26.5)
.812
(20.6)
1.93 Max.
(49.2)
2.45
(62.3)
2.65
(67.4)
EMBOSSED SAFETY COVER
CLEAR COVER FOR CLASS 6
SOLID STATE RELAYS
PREVENTS ELECTRICAL
SHOCK HAZARDS FROM
EXPOSED TERMINALS.
PART
NUMBER
15-700
Weight:: 0.476 oz. (13.5 g)
NOT SUPPLIED WITH RELAY. TO
BE ORDERED SEPARATELY IF
REQUIRED.
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
PAGE 108
S E C T I O N
5
5
TIME DELAY RELAYS
AND
SENSORS
5 TO 13 AMPERES
Page 109
Magnecraft
Struthers-Dunn
TIME DELAY RELAYS
211
RELAY CLASS/SERIES
FEATURES
8 or 11 PIN OCTAL
PLUG-IN.
CONTACT RESISTANCE:
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH:
222
MINIATURE PLUG-IN
8 PIN OCTAL PLUG-IN
"ON DELAY"
REPEAT CYCLE ON &
OFF DELAY
4 PROGRAMMABLE
FUNCTIONS
REPEATABILITY ±0.1%
62 PROGRAMMABLE
TIMING RANGES
FIELD ADJUSTABLE
BY KNOB
4 INPUT VOLTAGE
RANGES
INTERVAL, FLASHER,
ONE SHOT OR ON
& OFF DELAY AVAILABLE
REPEATABILITY ±0.1%
DPDT
DPDT
DPDT
DPDT
10 AMPS @
120 VAC, 30VDC
10 AMPS @
120 VAC, 30VDC
5AMPS @
120 VAC, 28 VDC
10 AMPS,
120VAC, 28 VDC
CONTACT CONFIGURATION:
CONTACT MATERIAL
8 or 11 PIN OCTAL
PLUG-IN.
67
"ON DELAY" OR
OFF DELAY"
CONTACT DATA
CONTACT RATING:
211 PROG
FIELD ADJUSTABLE
BY KNOB & DIP SWITCH
REPEATABILITY ± 2%
FIELD ADJUSTABLE
BY SCREW DRIVER
4 POLE STYLES AVAILABLE
±0.1 % REPEATABILITY
FIELD ADJUSTABLE
TIMING USING KNOBS.
P.C. TERMINALS
AVAILABLE..
Silver Cadmium Oxide
Silver Cadmium Oxide
Silver, Gold Overlay
Silver cadimum Oxide
50 MILLIOHMS
Max. Initial
50 MILLIOHMS
Max. Initial
50 Milliohms
Max. Initial
50 MILLIOHMS
Max Initial
1500 V rms
1500 V rms
1250 V rms
1500 V rms
120 VAC
24 VDC
AC - 90 to 130
DC - 20 to 32
120/24 VAC
24 VDC
AC - 90 to 130
DC - 20 to 32
DC - 10 to 14, 20 to 32
DC MODELS ONLY
DC MODELS ONLY
DC MODELS ONLY
- 30˚ C to + 55˚ C
- 55˚ C to + 85˚ C
- 30˚ C to + 55˚ C
- 55˚ C to + 85˚ C
- 30˚ C to + 80˚ C
- 40˚ C to + 100˚ C
- 30˚ C to + 55˚ C
- 55˚ C to + 85˚ C
0.1 Seconds to 120 Minutes
0.1 Seconds to 15 Minutes
AS SELECTED
AS SELECTED
0.1 to 30 Seconds
-
0.1 Second to 30 Minutes
0.1 Second to 30 Minutes
200,000 Operations
50,000,000 Operations
200,000 Operations
50,000,000 Operations
50,000 Operations
50,000,000 Operations
200,000 Operations
50,000,000 Operations
H
W
L
1.18 X .734 X 1.37
H
W
L
.1.75 X 2.37 X 3.49
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
INPUT VOLTAGE RANGE
REVERSE POLARITY
PROTECTION:
AC On Special Order
12 & 24 VDC
120 VAC
DC - SPECIAL ORDER
90 to 130 VAC
DC MODELS ONLY
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
TIMING VALUES
OPERATE MAX.:
RELEASE MAX:
LIFE
ELECTRICAL @ rated Load:
MECHANICAL:
DIMENSIONS
H
W
L
1.75 X 2..37 X 3.5"
H
W
L
1.75 X 2..37 X 3.5"
APPROVALS
APPLICATION DATA:
PAGE NUMBER
PAGE 113, 114
PAGE 115, 116
PAGE 117
PAGE 118
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 119
PAGE 110
Magnecraft
Struthers-Dunn
TIME DELAY RELAYS
388 SHORT BODY
388 KNOB
ADJUSTMENT
SQUARE BASE PLUG-IN SQUARE BASE PLUG-IN
OR FLANGE MOUNT
ON DELAY OR
OFF DELAY
ON DELAY OR
OFF DELAY
±0.1 % REPEATABILITY
±3 % REPEATABILITY
FIELD ADJUSTABLE
TIMING USING KNOB.
FIELD ADJUSTABLE
TIMING USING EXTERNAL RESISTOR
INTERVAL, FLASHER,
ONE SHOT OR ON
& OFF DELAY AVAILABLE
286/287
388 TRUE OFF DELAY
326/327
SQUARE BASE PLUG-IN
RETANGULAR PLUG-IN
8 or 11 PIN OCTAL PLUG-IN.
OFF DELAY
286 -ON DELAY, 287 0FF DELAY
"ON DELAY" OR OFF DELAY"
±3 % REPEATABILITY
FIELD ADJUSTABLE
TIMING USING KNOB.
POWER TO INPUT NOT
REQUIRED DURING
TIMING CYCLE.
±3 % REPEATABILITY
TIMING FIELD ADJUSTABLE BY KNOB OR
EXTERNAL RESISTOR.
1, 2 & 3 POLE 10 AMP
SWITCHING.
± 3% REPEATABILITY
FIELD ADJUSTABLE BY
KNOB OR EXTERNAL
RESISTOR.
1, 2 & 3 POLE 10 AMP
SWITCHING.
DPDT
DPDT
DPDT
SPDT, DPDT, 3PDT
SPDT, DPDT, 3PDT
12 AMPS,
120VAC, 28 VDC
12 AMPS,
120VAC, 28 VDC
12 AMPS @
120 VAC, 28 VDC
10 AMPS @
120/240 VAC, 28 VDC
10 AMPS @
120/240 VAC, 28 VDC
Silver cadimum Oxide
Silver cadimum Oxide
Silver Cadimum Oxide
Silver Cadimum Oxide
Silver Cadimum Oxide
50 MILLIOHMS
Max Initial
50 MILLIOHMS
Max Initial
50 MILLIOHMS
Max.initial
50 MILLIOHMS
Max.initial
50 MILLIOHMS
Max.initial
2000 V rms
2000 V rms
1500 V rms
1500 V rms
120 VAC
24 VDC
90 to 130 VAC
20 to 32 VDC
120 VAC
24 VDC
90 to 130 VAC
20 to 32 VDC
24 to 240VAC
12 to 115-125 VDC
85% Of Nominal
80% Of Nominal
24 to 240VAC
12 to 115-125 VDC
85% Of Nominal
80% Of Nominal
DC MODELS ONLY
DC MODELS ONLY
DC MODELS ONLY
DC MODELS ONLY
- 30˚ C to + 55˚ C
- 55˚ C to + 85˚ C
- 30˚ C to + 55˚ C
- 55˚ C to + 85˚ C
- 10˚ C to + 55˚ C
- 55˚ C to + 85˚ C
- 10˚ C to + 70˚ C
-
- 10˚ C to + 70˚ C
-
0.1 to 120 Seconds
0.1 to 120 Seconds
0.1 to 120 Seconds
1.0 to 180 Seconds
0.6 to 60 Seconds
0.1 to 300 Seconds
0.1 to 300 Seconds
100,000 Operations
5,000,000 Operations
100,000 Operations
5,000,000 Operations
100,000 Operations
5,000,000 Operations
100,000 Operations
10,000,000 Operations
100,000 Operations
10,000,000 Operations
1500 V rms
120 VAC
24 VDC
90 to 130 VAC
20 to 32 VDC
DC MODELS ONLY
H
W
L
1.40 X 1.53 X 1.90
PAGE 120, 121
PAGE 111
H
W
L
1.40 X 1.53 X 3.52 LG.
1.40 X 1.53 X 3.02 MED.
H HW W L L
1.40 X 1.53 X 3.52
1.37 X .1.50 X 3.35
1.37 X 1.37 X 3.0
PAGE 122, 123
PAGE 124
PAGE 125, 126
PAGE 127, 128
H
W
L
H
W
L
WEBSITE: www.magnecraft.com EMAIL:[email protected]
FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 91
Magnecraft
Struthers-Dunn
TIME DELAY RELAYS & SENSORS
236/237/238
SEE SECTION 10 FOR SOCKETS
12 PIN STYLE PLUG-IN.
WITH LOCKING CLIP
236 - ON DELAY, 237 OFF DELAY, 238 - ONE
SHOT
SCREWDRIVER OR
EXTERNAL RESISTOR
ADJUSTABLE.
±10 % REPEATABILITY.
246/247
235 CURRENT SENSOR 349 VOLTAGE SENSOR
SQUARE BASE PLUG-IN. 12 PIN STYLE PLUG-IN.
WITH LOCKING CLIP
1.5 TO 15 AMP SENSING
85 to 135 VAC 50 TO 400
STYLE 246 - ON DELAY, RANGE.
Hz SENSING RANGE.
STYLE 247 - OFF DELAY
±2% REPEATABILITY
1 AND 3 PHASE SENS±3% REPEATABILITY.
SPDT CONTACT
ING.
ARANGEMENTS
2 - 4 POLE CONTACT
LARGE CHOICE OF
ARANGEMENTS
OPTIONS
FIELD ADJUSTABLE
WITH KNOB
LARGE CHOICE OF
OPTIONS
12 PIN STYLE PLUG-IN.
WITH LOCKING CLIP
236 VOLTAGE SENSOR
SQUARE BASE OR
OCTAL PLUG-IN
UP TO 552 VAC OR 30
VDC SENSING RANGE.
±1% REPEATABILITY
LED POWER INDICATOR
FIELD ADJUSTABLE
WITH SCREW DRIVER
OR KNOB
1,2 & 3 POLE 10 AMP
SWITCHING
SPDT, DPDT, 3PDT
SEE CATALOG PAGE
SPDT
SEE CATALOG PAGE
SPDT, DPDT
10 AMPS @
120/240 VAC, 28 VDC
10 AMPS @
120/240 VAC, 28 VDC
10 AMPS @
120VAC/
28 VDC
10 AMPS @
120/240 VAC, 28 VDC
10 - 13 AMPS @
120/240 VAC, 28 VDC
Silver Cadmium Oxide
or Gold Diffused
50 MILLIOHMS
Max. Initial
Silver Cadmium Oxide
Silver Cadimum Oxide
50 MILLIOHMS
Max.initial
1500 V rms
Silver Cadmium Oxide
or Gold Diffused
50 MILLIOHMS
Max. Initial
Silver Cadmium Oxide
50 MILLIOHMS
Max. Initial
2500 V rms
1500 V rms
50 MILLIOHMS
Max. Initial
2000 V rms
1500 V rms
24 to 240VAC
12 to 115-125 VDC
85% Of Nominal
80% Of Nominal
24 to 240 VAC
12 TO 110-125 VDC
-
120 VAC
-
120VAC
-
120 to 480 VAC
24 VDC
-
DC MODELS ONLY
DC MODELS ONLY
-
N/A
N/A
- 10˚ C to + 70˚ C
-
- 10˚ C to + 70˚ C
-
- 30˚ C to + 55˚ C
- 40˚ C to + 85˚ C
- 10˚ C to + 60˚ C
- 30˚ C to + 55˚ C
- 40˚ C to + 85˚ C
0.2 to 200 Seconds
0.1 to 300 Seconds
1.5 to 15 Amps
85 TO 135 VAC
SEE CATALOG PAGE
100,000 Operations
10,000,000 Operations
100,000 Operations
10,000,000 Operations
200,000 Operations
5,000,000 Operations
100,000 Operations
10,000,000 Operations
100,000 Operations
5,000,000 Operations
H
W
L
1.46 X 2.62 X 4.56
PAGE 129, 130
H
W
L
1.46 X 2.62 X 4.42
PAGE 131
H
W
L
1.40 X 1.53 X 3.52
PAGE 132
H
W
L
1.46 X 2.62 X 4.56
PAGE 133
H
W
L
1.75 X 2.37 X 3.49
1.40 X 1.53 X 2.90
PAGE 134, 135
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 112
DESCRIPTIONS
OF TIME DELAY
FUNCTIONS
APPLICATION DATA
WHAT A TIME DELAY RELAY IS:
A Time Delay relay is a combination of an electromechanical output
relay and a control circuit. The control circuit is comprised of solid state
components and timing circuits that control operation of the relay and
timing range. Typical time delay functions include On-Delay, Off-Delay,
Repeat cycle, One Shot, Batch Control Interval, On-Delay & Off Delay
(Combination) and True Off Delay. Each function is explained below.
Time delay relays have a broad choice of timing ranges from less than
one second to hours. There is a choice of timing controls from calibrated
external knob, screwdriver adjusted or internally fixed timing for specific
applications. The output contacts on the electromechanical output relay
are direct wired to the output terminals. The contact load ratings are
specified for each specific type of time delay relay.
INPUT
POWER
ON
OFF
CLOSED
OPEN
CONTROL
SWITCH
TIMING FUNCTIONS:
ON-DELAY- (SLOW OPERATE RELAY) Upon application of power to
the input, the time delay period begins. At the end of the time delay
period, output contacts transfer. Input power must be removed to return
output contacts to home position and reset the control circuit. If input
power is interrupted before a timing period ends, timing stops. When
input power is restored , timing starts from the beginning.
Special requirements for Class 211 programmable relays: To function as
an On-Delay timer, as described above, a jumper wire must be connected
in place of the external control switch.
INPUT
POWER
OUTPUT
CONTACTS
TIMING FUNCTIONS (Continued)
ONE SHOT (MOMENTARY ACTUATION)
Continuous power must be applied to the input during all timing
sequences. Upon closure of external control Switch, output contacts
transfer and timing period begins. When timing period ends, output
contacts return home. Once the timing period begins, the control
switch may remain closed or opened without affecting timing. To
repeat this cycle, the control switch must be open, or opened at the
end of the timing period, and then closed to start timing period over
again.
ON
OFF
TRANSFERRED
HOME
DELAY
Some typical Applications: Cascade starting, Air Conditioning & heating
controls, Burglar Alarms, Power Outage delay, instrument Control.
OFF-DELAY (SLOW RELEASE RELAY)
Continuous power must be applied to input during all timing sequences.
Upon closure of external control switch, output contacts transfer. Upon
opening control switch, the timing period begins. When timing period
ends, output contacts return home. To repeat this timing cycle, the
control switch must be re-closed and then opened. If input power is
interrupted during timing cycle, the output contacts return to home
position and the control switch must be closed and reopened to start the
timing from the beginning. If the control switch closes during a timing
period, timing stops and output contacts remain transferred. When control
switch is opened, timing will start again from the beginning. The timing
period can be extended, repeatedly using the control switch in this way
until the last initiated timing period is permitted to end and output contacts
return home.
INPUT
POWER
ON
OFF
CONTROL
SWITCH
CLOSED
OPEN
OUTPUT
CONTACTS
TRANSFERRED
HOME
DELAY
DELAY
OUTPUT
CONTACTS
DELAY
TRANSFERRED
HOME
DELAY
Some typical Applications: Vending machines, dispensing controls,
machine control, welding control,
BATCH CONTROL (INTERVAL)
Upon application of power to the input, the output contacts transfer
and the delay period begins. At the end of the time delay period, the
output contacts return home. Input power must be interrupted to
recycle timer.
INPUT
POWER
OUTPUT
CONTACTS
ON
OFF
TRANSFERRED
HOME
DELAY
Some typical Applications: Machine control, End of process alarm,
Welding control, Photographic timing.
ON-DELAY & OFF-DELAY- (COMBINATION)
Continuous power must be applied to the input during all timing
sequences. Upon closure of the external control switch, first time delay
period T1 begins. When T1 period ends, output contacts transfer.
Then, When control switch is opened, second delay period T2 begins.
When T2 ends, output contacts return home. To repeat this timing
cycle, repeat this sequence from the beginning. If the prevailing open
or closed status of the control switch is changed during either T1 or T2
Timing periods, timing stops. Position of output contacts remain as they
were. Returning control switch to its pre-changed position restarts
interrupted timing period from the beginning and normal timing resumes.
INPUT
POWER
ON
OFF
CLOSED
OPEN
CONTROL SWITCH
OUTPUT
CONTACTS
T1
T2
T1 Interrupted
TRANSFERRED
HOME
T2 Interrupted
CONTROL SWITCH
OUTPUT
CONTACTS
T1
T2
CLOSED
OPEN
TRANSFERRED
HOME
Some typical Applications: Air Conditioning, automatic Door Controls,
Lighting Controls, burglar alarms, Vending Machines, conveyor
systems, instrument control.
Some typical Applications: Cascade starting & stopping of heavy
loads, laboratory equipment, machine control
REPEAT CYCLE (FLASHER) - Upon application of power to the input,
the Off time delay Period begins. The contacts transfer at the end of the
Off time Delay Period and the ON time delay period begins. At the end
of the ON time delay period output contacts return home and OFF time
delay period begins again. This sequence will continue as long as input
power is supplied to the Input Pins.
TRUE OFF DELAY- (SLOW RELEASE)
Upon application of power to the input, output contacts transfer. The
delay period begins when power is removed from the input. If power
is supplied to input during the timing period, time is reset and time
delay period starts over again when power is removed from the input.
INPUT
POWER
OUTPUT
CONTACTS
ON DELAY
ON DELAY
ON
OFF
TRANSFERRED
HOME
OFF DELAY
Some typical Applications: Signs, Product testing, signal devices,
machine control, Signal warning devices, conveyor control.
PAGE 113
INPUT
POWER
OUTPUT
CONTACTS
DELAY
OFF DELAY
ON
OFF
TRANSFERRED
HOME
Some typical Applications: Loss of power alarm control, Burglar
alarms.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
TIME DELAY
RELAYS
& SENSORS
APPLICATION DATA
SELECTING A TIMER'S MODE OF OPERATION
Selecting the correct Mode of operation (Timing Function) can be easily done by following the ladder diagram below. When selecting the
proper relay for your application, you must determine if the timer will be controlled by input power only, or the use of an external switch.
The next item to take into consideration is the load status during the timing cycle(s), and the contact status after the timing cycle.
Output status
During Timing
cycle (s).
Power is supplied
to Input & External
Switch ON/OFF
Power is
supplied to
Input
Timing Starts
When?
OFF
ON
ON/OFF
ON
ON
NOTE 1
Load Status at
end of First
Timing cycle.
ON
OFF
ON
OFF
OFF
ON
OFF
NOTE 3
NOTE 4
OFF
ON
NOTE 2
Load Status at
end of Second
Timing cycle.
Timer Type.
Applicable
Time delay
relays
that apply
to Mode of
Operation
ON
DELAY
211PROGX
211 SOX
67 SOX
326X
388 SOX
236X
246XBX
286X
OFF
OFF
NOTE 2
NOTE 5
TRUE
OFF
DELAY
REPEAT
CYCLE
BATCH
CONTROL
(INTERVAL)
OFF
DELAY
ONE
SHOT
388 SRX
222 PFX
238ABX
211PROGX
211 SRX
237X
327X
388 SRX
247XBX
287X
211PROGX
238X
ON/OFF
DELAY
211PROGX
NOTES:
1. Momentary power supplied to the input. Input power not required for timing cycle.
2. Continues to repeat timing cycles until power is removed from input
3. Upon closure of External switch, relay contacts switch and time period begins. The timing is not affected by the duration
of the External switch closure.
4. External switch is maintained closed, relay contacts switch at the end of first timing cycle.
5. External switch is maintained open for second timing cycle.
Footnote: ON = Relay coil energized, contacts switched. OFF = Relay coil de-energized, contacts in normal position.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 114
CLASS
211
OCTAL 8 & 11 PIN TIME DELAY RELAY
CLASS 211
± 0.1 % REPEATABILITY
DPDT, 10 AMP CONTACTS
FIELD ADJUSTABLE TIMING
WHEN USED WITH
SOCKET
70-464-1 (8PIN)
70-465-1 (11 PIN)
UL Recognized COMPLIES WITH
File No: E43641 REQUIREMENTS OF
* IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE.
*1EC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
THE CLASS 211 TIME DELAY RELAY
MAKES USE OF HYBRID CIRCUITRY,
COMBINING INTEGRATED CIRCUITS
FOR A MULTITUDE OF TIMING
FUNCTIONS, AND THE RELIABILITY
OF RELAY TECHNOLOGY.
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 211 TIME DELAY RELAYS
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability (repeat Accuracy
when Stabilized):
Timing change over temperature
and voltage range:
Timing Tolerance high end of range:
Timing Tolerance low end of range::
Reset time:
CONTACTS
Contact Configuration::
Contact Rating:
Contact Life:
Mechanical Life:
INPUT
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
On Delay, Off Delay
0.1 to 1 Sec, thru 8 to 120 Minutes
±0.1% max. or ± 33 mS AC min. or
± 10 mS DC. min.@ Constant voltage
& temperature
± 10%
- 0 to + 40%
+ 0 to - 40%
100 Milliseconds Max.
DPDT (2 Form C)
10 Amps @ 120VAC/30VDC Resistive
Load, 1/2 Hp @ 240 VAC, 1/3 Hp @120 VAC, NEMA B300
Pilot Duty.
200,000 Operations @ 120VAC, 10Amp resistive Load.
1,000,000 Operations @ 120 VAC,5 Amp Resistive Load
2,000,000 Operations @ 120VAC, 2 Amps Resistive Load.
50,000,000 Operations.
- 30 ˚C to + 55˚C
- 55˚C to + 85˚C
20 mA @ 120 VAC, 40 mA @ 24 VDC,
20 mA @ 48 VDC 80 mA @ 24 VDC,
15 mA @ 230 VAC, 80 mA @ 12 VDC.
PROTECTION
Reverse Polarity:
Transient:
Noise Immunity:
DC models only
UL 508 Surge test: 5000V for 50 uS
NEMA ICS2-230 2500 VAC
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
1500 V rms
1000 V rms
MECHANICAL
Enclosure:
Mounting:
Operating Position:
Weight:
Polycarbonate dust cover.
Standard 8 or 11 Pin Octal
Any
4 oz. (115 grams)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 115
CLASS
OCTAL 8 & 11 PIN TIME DELAY RELAY
211
OUTLINE DIMENSIONS
Dimensions shown in Inches and (Millimeters)
WIRING DIAGRAMS
VIEWED FROM PIN END
.562 (14.2)
▼
▲
▼
▲
4
ON DELAY
5
3
6
2
7
1
2.93
(74.4)
8
INPUT
2.37
(60.3)
EXTERNAL TRIGGER
SWITCH
5
●
▲
●
7
6
8
4
5
OFF DELAY
▼
▲
6
7
4
8
3
9
2
1 11
1
2
3
▼
▲
1.75
(44.4)
8 PIN OCTAL
ON-DELAY
10
INPUT
EXTERNAL SWITCH SHALL NOT BE CONNECTED
TO ANY EXTERNAL LOAD OR VOLTAGE. DAMAGE
TO INTERNAL COMPONENTS CAN OCCUR.
8
9
10
7
11
6
1.75
(44.4)
1
5
4
3
2
11 PIN OCTAL
OFF-DELAY
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
TIMING
RANGE
CROSS REFERENCE
TO
POTTER & BRUMFIELD
ON DELAY
W211ACPSOX-18
W211ACPSOX-5
W211ACPSOX-7
W211ACPSOX-8
W211ACPSOX-60
W211ACPSOX-61
W211ACPSOX-62
W211ACPSOX-63
W211CPSOX-1
W211CPSOX-3
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
120 VAC
24 VDC
24 VDC
0.1 to 1.0 Seconds
0.1 to 10 Seconds
1.0 to 180 Seconds
2.0 to 300 Seconds
1.0 to 15 Minutes
2.0 to 30 Minutes
4.0 to 60 Minutes
8.0 to 120 Minutes
0.1 to 10 Seconds
1.0 to 180 Seconds
CDB-38-70001
CDB-38-70003 *
CDB-38-70005 *
CGB-38-70005M
CGB-38-70010M
CGB-38-70050M
CB-1007B70
CDD-38-30003 *
CDD-38-30005 *
120 VAC
120 VAC
120 VAC
120 VAC
24 VDC
24 VDC
0.1 to 10 Seconds
1.0 to 180 Seconds
2.0 to 300 Seconds
1.0 to 15 Minutes
0.1 to 10 Seconds
1.0 to 180 Seconds
CHB-38-70011
CHB-38-70013
CHD-38-30011
CHD-38-30013
OFF DELAY
W211ACPSRX-5
W211ACPSRX-7
W211ACPSRX-8
W211ACPSRX-60
W211CPSRX-1
W211CPSRX-3
* ADDITIONAL EQUIVALENTS
TO P&B
W211ACPSOX-5
CGB-38-70010S
CHB-38-70001
CKB-38-70010
CB-1003B-70
W211CPSOX-1
CHD-38-30001
CB-1028D-30
W211ACPSOX-7
CKB-38-70180
CHB-38-70003
CB-1005B-70
W211CPSOX-3
CHD-38-30003
CB-1030D-30
SEE SECTION 10
FOR
MATING SOCKETS
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 116
CLASS
PROGRAMMABLE TIME DELAY RELAY
211PROGX
CLASS 211 PROGRAMMABLE TIME DELAY RELAY
± 0.1 % REPEATABILITY
3 INPUT VOLTAGE RANGES
✝ 4 PROGRAMMABLE FUNCTIONS
✝ 62 PROGRAMMABLE TIMING RANGES
RATED AT 10 AMPS, DPDT CONTACTS
WHEN USED
WITH SOCKET
70-465-1
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
OUTLINE DIMENSIONS
Shown in Inches and (Millimeters)
.562 (14.2)
2.93
(74.4)
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability (repeat Accuracy
when Stabilized):
Timing change over temperature and voltage range:
Timing Tolerance:
Reset time:
CONTACTS
Contact Configuration:
Contact Rating:
Mechanical Life:
9
8
11
10
7
On Delay, Off Delay, One Shot, On & Off Delay
0.1 to 1 Sec, thru 12 to 120 Minutes
±0.1% max. or ± 33 mS AC min., or ± 10 mS DC.
± 10%
± 20 %
100 mS Relay On (200 mS max Relay Off)
DPDT (2 Form C)
10 Amps @ 120VAC/30VDC Resistive
Load, 1/2 Hp @ 240 VAC, 1/3 Hp @ 120 VAC,
NEMA B300 Pilot Duty.
200,000 Operations @ 120VAC, 10 Amp
resistive Load.
1,000,000 Operations @ 120VAC, 5 Amp
Resistive Load
2,000,000 Operations @ 120VAC, 2 Amps
Resistive Load.
100,000,000 Operations.
INPUT
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
- 30 ˚C to + 55˚C
- 40˚C to + 85˚C
45 mA Max..
PROTECTION
Reverse Polarity:
Transient:
Noise Immunity:
Yes
UL 508 Surge test: 5000V for 50 uS
NEMA ICS2-230 2500VAC
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
1500 V rms
1000 V rms
MECHANICAL
Enclosure:
Mounting:
Mounting Position:
Weight:
Polycarbonate dust cover.
Standard 11 Pin Octal
Any
4 oz. (115 grams)
1
6
1.75
(44.45)
*1EC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
SPECIFICATIONS CLASS 211PROG TDR
Contact Life:
2.37
(60.19)
✝ SELECTION OF TIMING RANGE AND TIMING
FUNCTIONS ARE OBTAINED BY SETTING
SWITCH POSITIONS IN A DIP SWITCH BANK
COMPLIES WITH
REQUIREMENTS OF
* IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE.
UL Recognized
File No: E43641
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
THE CLASS 211 TIME DELAY RELAY
MAKES USE OF HYBRID CIRCUITRY,
COMBINING INTEGRATED CIRCUITS
FOR A MULTITUDE OF TIMING
FUNCTIONS, AND THE RELIABILITY
OF RELAY TECHNOLOGY.
SEE SECTION 10
FOR
MATING SOCKETS
5
4
3
2
11 PIN OCTAL PLUG-IN
WIRING DIAGRAMS
VIEWED FROM PIN END
** EXTERNAL CONTROL
SWITCH
●
▲
●
+
5
▼
▲
6
7
8
4
3
9
2
1 11
▼
▲
24VAC/VDC
10
-
INPUT
120VAC 50/60 Hz
To function as a On-Delay timer, a jumper wire must be
connected in place of the external control switch.
PAGE 117
NOMINAL
TIMING
INPUT
RANGE
VOLTAGE
ON DELAY, OFF DELAY, ONE SHOT, ON & OFF DELAY
62 Programmable
120 VAC, 50/60Hz
W211PROGX-1
Timing Ranges.
24VAC/VDC on Pin 7
PART NUMBER
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
**EXTERNAL CONTROL SWITCH REQUIRED FOR OFF DELAY, ONE SHOT AND
ON & OFF DELAY FUNCTIONS.
EXTERNAL SWITCH SHALL NOT BE CONNECTED TO ANY EXTERNAL LOAD OR
VOLTAGE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
MINIATURE 5 AMP TIME DELAY RELAY
67
CLASS 67 TIME DELAY RELAY
± 2% REPEATABILITY
DC OPERATION
PLUG-IN/SOLDER TERMINALS
UL Recognized
File No: E43641
SPECIFICATIONS CLASS 67 TIME DELAY RELAYS
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability (repeat Accuracy
when Stabilized):
Reset time:
CONTACTS
Contact Configuration:
Contact Rating:
Contact Life:
On Delay,
0.1 to 240 Seconds
± 2% max. @ Nominal Voltage, 25˚C
100 Milliseconds Max
Mechanical Life:
DPDT ( 2 Form "C").
5 Amps @ 120VAC/28 VDC Resistive
50,000 Operations @ 120 VAC 5 Amps
Resistive
1,500,000 Operations @ 120VAC, 2 Amps
resistive Load.
12,000,000 Operations @ 120 VAC 1Amp
Resistive Load
50,000,000 Operations
INPUT
Nominal Input Voltage:
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
12 VDC, 24 VDC
-30˚C to + 55˚C
-50˚C to +85˚C
40 mA @ 24 VDC, 80 mA @ 12 VDC
PROTECTION
Reverse Polarity:
Transient:
DC models only
Twice Nominal Voltage for 1 Millisecond
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
500 V rms
1250 V rms
MECHANICAL
Enclosure:
Mounting:
OUTLINE DIMENSIONS
Dimensions shown are in Inches and ( Millimeters).
1.18 Max.
(30.2)
.094
(2.3)
3-48UNC-2A Thd.
.170
(4.3)
Elongated Hole .100 x .040 ( 2 x .1)
Special Note:
.400
(10.1)
.458
(11.6)
.200 Max.
(5.1)
All Contact Terminals are .010 Thick
all coil terminals are .018 Thick.
Polycarbonate dust cover.
Socket Plug-in/Solder. Also Available with
P.C. Terminals.
1.2 oz. 35.2 Grams
Weight:
.734
(18.6)
1.37
(34.9)
WIRING DIAGRAM
Use 6 Pole Socket with plug-in style
relays. .
16
6
7
14
15
5
+
1
4
VIEWED FROM PIN END
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
TIMING
RANGE
CROSS REFERENCE
TO
POTTER & BRUMFIELD
"ON" DELAY
W67CPSOX-1
W67CPSOX-2
12 VDC
24 VDC
0.1 to 30 Seconds R12-3012X2E1
0.1 to 30 Seconds R12-3024X2E1
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
OTHER COIL VOLTAGES, TIMING RANGES, P.C. TERMINALS AND
4PDT CONTACT COMBINATION AVAILABLE ON SPECIAL ORDER.
120 VAC INPUT DESIGN AVAILABLE, CONTACT FACTORY.
.280
(7.11)
.56
(14.2)
CHASSIS CUTOUT
for panel mounting.
.790
(19.8)
.656
(16.7)
.352
(8.9)
.140
(3.5)
.109 DIA. (2.77)
SEE SECTION 10
FOR
MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 118
CLASS
OCTAL 8 PIN REPEAT CYCLE TIMER
222
CLASS 222
± 0.1 % REPEATABILITY
DPDT, 10 AMP CONTACTS
FIELD ADJUSTABLE ON
AND OFF TIME.
COMPLIES WITH
REQUIREMENTS OF
* IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE.
UL Recognized
File No. E43641
*1EC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
SEE SECTION 10
FOR
MATING SOCKETS
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 222 REPEAT CYCLE TIMER
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability (repeat Accuracy
when Stabilized):
THE CLASS 222 REPEAT CYCLE TIME
DELAY RELAY CAN BE ADJUSTED TO
ACHIEVE INDEPENDENT TIME
SETTINGS FOR BOTH "ON" AND
"OFF" TIMING RANGES.
Timing change over temperature and voltage range:
Timing Tolerance high end of
range:
Timing Tolerance low end of
range::
Reset time:
.562 (14.2)
CONTACTS
Contact Configuration:
Contact Rating:
Contact Life:
2.93
(74.4)
Mechanical Life:
INPUT
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
2.37
(60.3)
7
6
5
8
4
1
1.75
(44.4)
2
3
8 PIN OCTAL
ON-DELAY
WIRING DIAGRAMS
VIEWED FROM PIN END
▼
▲
Repeat cycle timing only.
0.1 to 1 Sec, to 24 hours
±0.1% max. or ± 33 mS AC min. or
± 10 mS DC min. at constant voltage &
temperature..
± 10%
- 0 to + 40%
+ 0 to - 40%
100 Milliseconds Max.
DPDT (2 Form C)
10 Amps @ 120VAC/30VDC Resistive
Load, 1/2 Hp @ 240 VAC, 1/3 Hp @ 120 VAC,
NEMA B300 Pilot Duty.
200,000 Operations @ 120VAC, 10Amp
resistive Load.
1,000,000 Operations @ 120 VAC 5 Amp
Resistive Load
2,000,000 Operations @ 120VAC 2 Amps
Resistive Load.
50,000,000 Operations.
- 30 ˚C to + 55˚C
- 55˚C to + 85˚C
25 mA @ 120 VAC, 45 mA @ 24 VDC,
24 mA @ 48 VDC 85 mA @ 24 VDC,
25 mA @ 230 VAC.
PROTECTION
Reverse Polarity:
Transient:
Noise Immunity:
DC models only
UL 508 Surge test: 5000V for 50 uS
NEMA ICS2-230 2500VAC
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
1500 V rms
1000 V rms
MECHANICAL
Enclosure:
Mounting:
Mounting Position:
Weight:
Polycarbonate dust cover.
Standard 8 Pin Octal
Any
5 oz. (132 grams)
NOMINAL
INPUT
VOLTAGE
TIMING RANGE
"ON" (T1) TIMING
TIMING RANGE
"OFF" (T2) TIMING
CROSS REFERENCE
TO
POTTER & BRUMFIELD
120 VAC
120 VAC
120 VAC
0.1 to 10 Seconds
3 to 300 Seconds
2 to 30 Minutes
0.1 to 10 Seconds
3 to 300 Seconds
2 to 30 Minutes
CRB-48-70010
-
▼
▲
4
5
6
3
2
7
1
8
INPUT
PART NUMBERS
REPEAT CYCLE
W222ACPFX-11
W222ACPFX-16
W222ACPFX-27
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
OTHER VOLTAGES AND TIMING RANGES AND AVAILABLE THRU SPECIAL ORDER. CONTACT FACTORY.
PAGE 119
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
12 AMP ADJUSTABLE TIME DELAY RELAY
UL Recognized
File No: E43641
388
CLASS 388
SHORT BODY
EXTERNAL
RESISTANCE
ADJUSTABLE
COMPLIES WITH
REQUIREMENTS OF
* IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE.
*1EC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
± 3 % REPEATABILITY
DPDT, 12 AMP CONTACTS
FIELD ADJUSTABLE TIMING
"ON" or "OFF" DELAY FUNCTIONS
PLUG-IN STYLE
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 388 TIME DELAY RELAYS
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability:
Percent Timing change over temperature
and voltage Range:
Timing Tolerance high end
Timing Tolerance low end:
CONTACTS
Contact Configuration:
Contact Rating:
Contact Life:
Mechanical Life:
On Delay, Off Delay
.1 to 1 Seconds to 24 Hours
±0.1% max. or ± 33 mS AC min. or
± 10 mS DC.@ Constant Voltage & Temperature.
FLANGE MOUNT STYLE
± 10%
- 0 to + 40%
+ 0 to - 40%
DPDT (2 Form C)
12 Amps @ 120 VAC/28 VDC Resistive
1/3 HP, 120 VAC, 1/2 HP, 240 VAC
B300 Pilot Duty.
100,000 Operations @ 120 VAC 12 Amps Resistive Load.
1,000,000 Operations @ 28 VDC 5 Amps Resistive Load.
5,000,000 Operations
INPUT
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
- 30 ˚C to + 55˚C
- 55˚C to + 85˚C
20 mA @ 120 VAC, 60 mA @ 24 VDC,
PROTECTION
Reverse Polarity:
Transient:
DC models only
Twice nominal voltage for 1 millisecond
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
1500 V rms
1000 V rms
MECHANICAL
Enclosure:
Operating Position:
Weight:
Polycarbonate dust cover.
Any
3 oz. 96 grams
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 120
CLASS
388
12 AMP ADJUSTABLE TIME DELAY RELAY
OUTLINE DIMENSIONS
Dimensions Shown in "Inches " & (Millimeters).
2.90 Max.
(73.8)
2.50
(63.5)
1.53 Max.
(38.8)
.187 (4.74)
Q.C. Terminals
1.90 Max.
(48.4)
1.40 Max.
(35.7)
1
4
2
5
3
6
7
8
9
A
B
THE PLUG-IN STYLE TIMER HAS THE SAME CASE DIMENSIONS
AS THE FLANGE MOUNT STYLE EXCEPT IT HAS NO FLANGE
AND IT IS ALSO SOCKET MOUNTABLE.
WIRING DIAGRAMS FOR FIXED STYLE TIME DELAY RELAYS
Voltage must be applied to terminals "A" & "B" continuously.
EXTERNAL
RESISTOR
EXTERNAL
RESISTOR
1
2
3
4
5
6
7
8
9
A
EXTERNAL
SWITCH
B
+ INPUT OFF DELAY
1
2
3
4
5
6
7
8
9
B
A
+ INPUT ON DELAY
THE EXTERNAL TRIGGER SWITCH SHOULD NOT BE CONNECTED
TO ANY EXTERNAL LOAD OR VOLTAGE SOURCE. DAMAGE TO
INTERNAL COMPONENTS CAN OCCUR.
NOMINAL
TIMING
EXTERNAL
INPUT
RANGE
RESISTOR
VOLTAGE
ON DELAY PLUG-IN STYLE
0.1 to 10 Seconds
W388ACPSOX-1
120 VAC
20K OHMS
1.0 to 120 Seconds PER SECOND
W388ACPSOX-2
120 VAC
16 K OHMS
0.1 to 10 Seconds
W388CPSOX- 1
24 VDC
1.0 to 120 Seconds PER SECOND
W388CPSOX-2
24 VDC
ON DELAY SURFACE MOUNT FLANGE STYLE
0.1 to 10 Seconds
W388ACQSOX-1
120 VAC
20 K OHMS
1.0 to 120 Seconds PER SECOND
W388ACQSOX-2
120 VAC
1.0
to
120
Seconds
W388CQSOX-2
24 VDC
OFF DELAY PLUG-IN STYLE
1.0 to 120 Seconds 16KΩ per Second
W388CPSRX-22
24 VDC
PART NUMBER
CROSS REFERENCE
TO
POTTER & BRUMFIELD
CUF-41-70010
CUF-41-70120
CUH-41-30010
CUH-41-30120
CUF-42-70010
CUF-42-70120
CUH-42-30120
-
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10
FOR MATING SOCKETS
PAGE 121
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
12 AMP ADJUSTABLE TIME DELAY RELAY
CLASS
388
CLASS 388 ADJUSTABLE
UL Recognized
File No: E43641
COMPLIES WITH
REQUIREMENTS OF
* IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE.
CHOICE OF LONG or MEDIUM BODY
± 0.1 % REPEATABILITY
DPDT, 12 AMP CONTACTS
FIELD ADJUSTABLE TIMING
"ON" or "OFF" DELAY FUNCTIONS
*1EC = INTERNATIONAL
ELECTROTECHNICAL ICOMMISSION
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 388 TIME DELAY RELAYS
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability:
Timing change over temperature
and voltage Range:
Timing Tolerance high end:
Timing Tolerance low end:
Reset Time:
CONTACTS
Contact Configuration:
Contact Rating:
Contact Life:
Mechanical Life:
INPUT
Temperature Range (Operate):
Temperature Range (Storage):
Steady State Input Current:
PROTECTION
Reverse Polarity:
Transient:
Noise Immunity:
On Delay, Off Delay
.1 to 1 Seconds to 8 to 120 Minutes
±0.1% ± 33 mS AC min. or ± 10 mS DC.
@ Constant Voltage & Temperature.
± 10%
- 0 to + 40%
+ 0 to - 40%
100 mS Max.
DPDT (2 Form C)
12 Amps @ 120 VAC/28 VDC Resistive
1/3 HP, 120 VAC, 1/2 HP, 240 VAC
NEMA B300 Pilot Duty.
100,000 Operations @ 120 VAC 12 Amps Resistive Load.
1,000,000 Operations @ 120 VAC 5 Amps Resistive Load
2,000,000 Operations @ 120 VAC 2 Amps Resistive Load.
5,000,000 Operations
- 30 ˚C to + 55˚C
- 55 ˚C to + 85˚C
20 mA @ 120 VAC, 60 mA @ 24 VDC, 20mA @ 48 VDC,
80 mA @ 24 VAC, 15 mA @ 230 VAC, 120mA @ 12 VDC
DC models only
UL 508 Surge test: 5000V for 50 uS (Long Body Only).
Twice Nominal for 1 Millisecond (Medium Body Only).
NEMA ICS2-230: 2500 VAC (Long Body Only).
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
2000 V rms
1000 V rms
MECHANICAL
Enclosure:
Terminals:
Mounting Position:
Weight:
Polycarbonate dust cover.
3/16" Q.C. Terminals. P.C. Available.
Any
Aprox. 4 oz., 96 grams
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 122
CLASS
12 AMP ADJUSTABLE TIME DELAY RELAY
388
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters).
1
4
2
5
3
6
7
8
9
A
1.40
(35.7)
B
1.53
(38.8)
.312
(7.9)
.625
2.90 Max. (Long Body)
(15.8)
(73.8)
2.40 Max. (Medium Body)
(61.1)
WIRING DIAGRAMS FOR ADJUSTABLE STYLE TIME DELAY RELAYS
Voltage must be applied to terminals "A" & "B" continuously.
EXTERNAL
TRIGGER SWITCH
1
2
3
1
2
3
1
2
3
4
5
6
4
5
6
4
5
6
7
A
8
9
7
B
A
+ INPUT OFF DELAY LONG BODY
8
+
INPUT
9
7
B
A
-
ON DELAY LONG & MEDIUM BODY
EXTERNAL
TRIGGER
SWITCH
8
9
B
INPUT
+
OFF DELAY MEDIUM BODY
THE EXTERNAL TRIGGER SWITCH SHOULD NOT BE CONNECTED TO ANY EXTERNAL LOAD OR VOLTAGE
SOURCE. DAMAGE TO INTERNAL COMPONENTS CAN OCCUR.
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
TIMING
RANGE
ON DELAY - LONG BODY
0.1 to 10 Seconds
120 VAC
W388ACPSOX-42
1.0 to 180 Seconds
120 VAC
W388ACPSOX-44
OFF DELAY - LONG BODY
W388CPSRX-2
24 VDC
0.1 to 10 Seconds
W388CPSRX-4
24VDC
1.0 to 180 Seconds
OFF DELAY - MEDIUM BODY
CROSS REFERENCE
TO
POTTER & BRUMFIELD
-
W388ACPSRX-101
120 VAC
1.0 to 120 Seconds
ON DELAY - MEDIUM BODY
-
W388ACPSOX-101
120 VAC
1.0 to 120 Seconds
OFF DELAY - MEDIUM BODY
CLB-51-70120 *
W388CPSRX-23
24 VDC
1.0 to 120 Seconds
ON DELAY - MEDIUM BODY
-
W388CPSOX-101
-
24 VDC
1.0 to 120 Seconds
* THE CASE LENGTH ON THE MAGNECRAFT MEDIUM BODY IS 2.40 LONG VS P&B, 2.156 LONG.
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION 10
FOR MATING SOCKETS
PAGE 123
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
ADJUSTABLE TRUE OFF DELAY RELAY
UL Recognized
File No: E43641
COMPLIES WITH
REQUIREMENTS OF
* IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE.
*1EC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
388
CLASS 388
TRUE OFF DELAY
DOES NOT REQUIRE CONTROL
POWER DURING TIMING CYCLE
± 3% REPEAT TIMING ACCURACY
FIELD ADJUSTABLE
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
(SEE SECTION 11 FOR RELEVANT UTILIZATION CATEGORIES.)
SPECIFICATIONS CLASS 388 TRUE OFF DELAY
TIMING
Operating Modes Available:
Timing Adjustments Available:
Repeatability:
Reset time:
True Off Delay
0.1 to 10 Seconds thru 0.5 to 5 Minutes
± 3% @ Nominal Voltage & 25˚C
100 mS Max.
INPUT
Temperature Range Operate:
Temperature Range Storage:
Input Current:
- 10˚C to + 55˚C
- 40˚C to + 85˚C
10 mA @ 120VAC, 15 mA @ 24VDC fixed
CONTACTS
Contact Configuration:
Contact Rating:
The Class 388 Adjustable True Off Delay
Relay combines a Solid State Timing circuit
with a state of the art Magnetic Latching
relay. This combination allows the relay
to Pull-in when power is applied to the input.
Timing starts when power is removed from
the input and at the end of the preset timing
period the relay will dropout.
DPDT (2 Form C)
12 Amps @ 120 VAC/28 VDC Resistive
1/3 HP, 120 VAC, 1/2 HP, 240 VAC
NEMA B300 Pilot Duty.
100,000 Operations @ 120 VAC 12 Amps Resistive
Load.
1,000,000 Operations @ 120 VAC 5 Amps Resistive
Load
2,000,000 Operations @ 120 VAC 2 Amps Resistive
Load.
Contact Life:
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
Transient:
Reverse Polarity Protection:
WIRING DIAGRAM
Viewed from Pin End
2000 V rms
1000 V rms
2000 VAC for 50 Microseconds
(DC Models Only)
MECHANICAL
Enclosure:
Mounting:
Terminals:
Weight:
1
2
3
4
5
6
7
8
9
B
A
Polycarbonate dust cover
Square Base Plug-in
3/16" X .020" Quick Connect, P.C. Terminals Available
4 oz. 96 grams
+ INPUT Observe polarity on DC models
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and Millimeter
.312
(7.9)
1.53
(38.8)
1
4
2
5
3
6
7
8
9
A
B
1.40
(35.7)
2.90 Max.
(73.8)
.625
(15.8)
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
TIMING
RANGE
AC OPERATED
W388ACPSRX-29
W388ACPSRX-30
DC OPERATED
W388CPSRX-35
W388CPSRX-36
120 VAC
120 VAC
0.6 to 60 Seconds
0.1 to 10 Seconds
24 VDC
24 VDC
0.1 to 10 Seconds
0.6 to 60 Seconds
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
SEE SECTION
10
FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 124
SERIES
286/287 10 AMP SQUARE BASE TIME DELAY RELAY
SERIES 286 ON DELAY, 287 OFF DELAY
AC OR DC INPUT
1, 2 OR 3 POLE 10 AMP CONTACTS.
UL Recognized
File No. E13224
GENERAL SPECIFICATIONS SERIES 306 TIMER
INPUT
Coil Voltage
Nominal Voltage:
AC: 24 to 240, DC: 12 to 125
Minimum Oper. Voltage:
AC - 85% of Nominal
DC - 80% of Nominal
Max. allowed voltage:
110% of nominal voltage
CONTACTS
Contact Material:
Rating:
The series 286 On Delay & 287 Off Delay
Time Delay Relays have timing ranges
from 0.1 to 300 Seconds. The 286 timer has
up to three poles and the 287 timer has up to
two poles. The 286 & 287 time delay relays
are rated at 10 Amps, 120/240 Vac, 28 Vdc.
SEE SECTION 10
FOR
MATING SOCKETS
Silver Cadmium Oxide.
10 Amps @ 120/240 VAC
10 Amps @ 28 VDC
1/3 Hp@ 120AC
1/2 Hp @ 240 VAC
OPERATIONAL CHARACTERISTICS
Repeatability:
± 3% @ 20˚C to 25˚C (AC +16 mS)
Accuracy:
Adjustable ± 10% Within temperature
& voltage range. Fixed: ± 10% @ 25˚C
Recycle Time:
100 mS up to 60 Seconds\
150 mS, 60 to 300 Seconds
INSULATION CHARACTERISTICS
Dielectric Strength:
All Mutually Insulated Points:
Insulation Resistance:
Transient Protection:
False Contacting:
Inverse polarity protection:
ENVIRONMENTAL CAPABILITIES
Ambient Temperature Rating:
Struthers-Dunn
Typical Part Number
10˚C to +70 ˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear Polycarbonate
5.0 oz approx. (142 g)
WIRING DIAGRAM
286 XAX C 001 F 120A
Series
286 - ON DELAY
287 - OFF DELAY
Viewed from Terminal Side
EXTERNAL
RESISTOR
Contact Arrangements
XAX (SPDT)
XBX (DPDT)
XCX (3PDT)
Mounting Options
C
Plug-in
C1Note 1 Bracket
Note 1
Top Stud
CS1
C2
Side Tapped Hole
CS2
Side Stud
+
Timing Ranges
0.1 - 1.0 Sec - Code 001
0.2 - 2.0 Sec - Code 002
1.0 - 10 Sec - Code 010
3.0 - 30 Sec - Code 030
6.0 - 60 Sec - Code 060
18 - 180 Sec - Code 180
30 - 300 Sec - Code 300
Operating Voltage
AC; 24, 48, 120, 240 (Add "A" )
DC; 12, 24, 48, 115-125 (Add "D")
(F * Models) - timing code does not apply. Specify single delay time requirement
(R ** Models)- Available only for SPDT and DPDT models. External potentiometer
required.
Example of typical fixed time delay relay part number- 286XBXCS1-3.5F-120A
(ON DELAY, DPDT, TOP STUD, 3.5 SEC FIXED, 120 VAC COIL INPUT)
+
EXTERNAL
RESISTOR
EXTERNAL
SWITCH
287 MODEL
ONLY
1
2
3
1
2
3
4
5
6
4
5
6
7
8
9
7
8
9
A
INPUT
B
-
1
2
3
4
5
6
7
8
9
A
INPUT
B
+
B
A
INPUT
EXTERNAL
- SWITCH
287 MODEL
ONLY
286XBX (DPDT)
287XBX (DPDT)
286XAX (SPDT)
287XAX (SPDT)
Adjustment Options
Adjustment Knob) - No Code
Fixed Delay - Specify Fixed Time & Code F *
Remote Adjustment - Code R **
PAGE 125
500 V rms across open contacts
1500 V rms between current carrying
parts
1000 Megohms min. @ 500 VDC.
5 mS, 0 to 2000 V 20 uSec peak
No false contacting is power is
interupted during timing.
DC coil are polarity protected.
-
SEE SECTION
10
FOR MATING SOCKETS
-
ON DELAY
286XCX
Notes:
Note 1: Bracket & top stud Not available with
adjustable timing.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
10 AMP SQUARE BASE TIME DELAY RELAY 286/287
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
SIDE STUD OR TAPPED HOLE, ADJUSTABLE TIMING
PLUG-IN, ADJUSTABLE TIMING
.125
(3.17)
.625
(15.87)
.625
(15.87)
Anti-rotation Tab
Fits 0.177 dia. hole
(No. 16 Drill)
CODE C
CODE C2, CS2
2.90 Max.
(73.66)
2.90 Max.
(73.66)
.437
(11.1)
12
12
6-32 tapped hole
or 6-32 stud
1.125 Max.
(28.57)
6-32 Stud
.281 typ.
(7.14)
.281 typ.
(7.14)
1.50 Max.
(38.1)
1.375 Max.
(34.9)
.296
(7.54)
1.375Max.
(34.9)
1.50 Max.
(38.1)
1.375Max.
(34.9)
1.50 Max.
.160 (38.1)
(4.06)
PLUG-IN FIXED OR REMOTE TIMING
1.375Max.
(34.9)
1.50 Max.
(38.1)
BRACKET FIXED OR REMOTE TIMING
1.875 Max.
(47.62)
CODE C
1.90 Max.
(48.26)
CODE C1
2.90 Max.
(73.66)
2.50
(63.5)
.281 typ.
(7.14)
.281 typ.
(7.14)
TERMINALS .187 X .020
(4.74 X .508)
TERMINALS .187 X .020
(4.74 X .508)
SIDE TAPPED HOLE, FIXED OR REMOTE TIMING
SIDE STUD, FIXED OR REMOTE TIMING
.125 Max.
(3.17)
1.375Max.
(34.9)
.125 Max.
(3.17)
1.50 Max.
(38.1)
Anti-rotation Tab
Fits 0.177 dia. hole
(No. 16 Drill)
CODE CS2
.437
(11.1)
1.375Max.
(34.9)
1.50 Max.
(38.1)
CODE C2
.437
(11.1)
1.875 Max.
(47.62)
12
12
Anti-rotation Tab
Fits 0.177 dia. hole
(No. 16 Drill)
1.875 Max.
(47.62)
6-32 Stud
6-32 Tapped hole
.281 typ.
(7.14)
.296
(7.54)
6-32 STUD
.125 Max.
(3.17)
.281 typ.
(7.14)
1.125 Max.
(28.57)
1.125 Max.
(28.57)
TOP STUD FIXED OR REMOTE TIMING
.375
(9.52)
.281
(7.14)
.437
(11.11)
CODE CS1
1.50 Max.
(38.1)
1.875 Max.
(47.62)
1
4
2
5
3
6
7
8
9
A
1.375 Max.
(34.9)
B
ALL TERMINALS .187 X .020
(4.74 X .508)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 126
SERIES
OCTAL 8 & 11 PIN TIME DELAY RELAY
326/327
SERIES 326 ON DELAY, & 327 OFF DELAY
AC OR DC INPUT
1, 2 OR 3 POLES
8 OR 11 PIN OCTAL BASES
TIMING: FIXED, ADJUSTABLE OR REMOTE
UL Recognized
File No. E13224
GENERAL SPECIFICATIONS SERIES 306 TIMER
INPUT
Coil Voltage
Nominal Voltage:
Minimum Oper. Voltage:
Max. allowed voltage:
CONTACTS
Contact Material:
Rating:
AC: 24 to 240, DC: 12 to 125
AC - 85% of Nominal
DC - 80% of Nominal
110% of nominal voltage
Silver Cadmium Oxide.
10 Amps @ 120/240 VAC
10 Amps @ 30 VDC
1/3 Hp@ 120AC
1/2 Hp @ 240 VAC
OPERATIONAL CHARACTERISTICS
Repeatability:
DC: ± 3% @ 20˚C. AC: ± 3% +16 mS @
20˚C.
Accuracy:
Adjustable ± 10% Within temperature
& voltage range.
Switching time of output relay: 20 mS
Min. waiting time before starting
next cycle (reset time):
100 mS (for timing cycle up to 60 sec.)
150 mS (for timing cycle 60 to 300 sec)
INSULATION CHARACTERISTICS
Dielectric Strength:
500 V rms across open contacts
All Mutually Insulated Points
1500 V rms between mutually insulated
conductive elements.
Insulation Resistance:
1000 Megohms min. @ 500 VDC.
Transient Protection:
5 mS, 0 to 2000 V 20 uSec peak
ENVIRONMENTAL CAPABILITIES
Ambient Temperature Rating:
-10˚C to +70 ˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear Polycarbonate
5.0 oz approx. (142 g)
Struthers-Dunn
Typical Part Number
326 XAX 48P 001
F 120A
Series
326 - 0N DELAY
327 - OFF DELAY
Contact Arrangements
XAX (SPDT)
XBX (DPDT)
XCX (3PDT)
Construction Style
Octal style plug-in - Code 48P
Non Standard Wiring - Code 48P-K
Timing Ranges
0.1 - 1.0 Sec - Code 001
0.2 - 2.0 Sec - Code 002
1.0 - 10 Sec - Code 010
3.0 - 30 Sec - Code 030
6.0 - 60 Sec - Code 060
18 - 180 Sec - Code 180
30 - 300 Sec - Code 300
Adjustment
Adjustment Knob) - No Code
Fixed Delay - Specify Fixed Time & Code F *
Remote Adjustment - Code R **
Operating Voltage
AC; 24, 48, 120, 240 (Add "A" )
DC; 12, 24, 48, 115-125 (Add "D")
(F * Models) - timing code does not apply. Specify single delay time requirement
(R ** Models)- Available only for SPDT and DPDT models. External fixed or
adjustable resistor required.
Example of typical fixed time delay relay part number- 326XBX48P3.5F-120A
(ON DELAY, DPDT, OCTAL PLUG, 3.5 SEC FIXED, 120 VAC POWER INPUT)
PAGE 127
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
OCTAL 8 & 11 PIN TIME DELAY RELAY
326/327
OUTLINE DIMENSIONS
Knob not on
fixed or remote
models
.625
(15.87)
DIMENSION A
ADJUSTABLE
WITH KNOB STYLE
3.0 (76.2)
FIXED OR REMOTE
STYLE 326 Only
2.25 (57.15)
Dimensions shown are in INCHES and (millimeters)
A
5
4
6
8 PIN OCTAL BASE
2
7
1
6
5
3
7
4
8
3
9
2
1.375
(34.9)
11 PIN OCTAL BASE
10
1
8
11
1.375
(34.9)
1.375
(34.9)
WIRING DIAGRAMS
(VIEWED FROM PIN END) ✱ ✱
MODELS WITH INTERNAL TIMING RESISTOR
SLOW RELEASE
SLOW OPERATE
4
▼
▲
5
3
6
2
7
+
1
8
External
Switch
▼
▲
4
-
6
2
7
+
✝
326XAX48P
1
INPUT
▼
▲
8
3
9
1 11
+
✝
INPUT
326XBX48P
5
7
4
2
-
8
6
5
5
3
▼
▲
▼
▲
6
7
4
Jumper 8
3
9
2
10
+
-
1 11
✝
INPUT
326XCX48P
▼
▲
10
✝✝
INPUT
327XBX48P-K
Non Standard
MODELS WITH EXTERNAL (REMOTE) TIMING RESISTOR
SLOW OPERATE
SLOW RELEASE
✱ External
✱ External
✱ External
Resistance
Resistance
Resistance
✱ External
Resistance
4
+
5
5
3
6
2
7
1
8
▼
▲
6
8
3
9
2
-
INPUT
326XAX48P-R
+
4
7
4
1 11
▼
▲
10
-
INPUT
326XBX48P-R
+
5
5
3
6
2
7
1
8
▼
▲
-
External
INPUT Switch
327XAX48P-R
6
7
4
8
3
9
2
+
1 11
INPUT
▼
▲
10
- External
Switch
327XBX48P-R
✱ External Resistor for remote timing adjustment on models 326 or
327 with code R.
✝ This Diagram also applies to fixed time (code F) models.
✝✝ Duplicates wiring of some similar relays made by others.
✱ ✱ Observe Polarity on DC input models
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 128
SERIES
236/237/238
12 PIN, 10 AMP, TIME DELAY RELAY
SERIES 236 ON DELAY, 237 OFF DELAY & 238 BATCH CONTROL
INTERVAL (SEE NOTE 3)
UL Recognized
File No. E13224
AC OR DC INPUT
DPDT OR DPDT WITH 1 N.O. CONTACT ON SERIES 236 & 238
12 PIN PLUG-IN WITH LOCKING CLIP
TIMING: SCREWDRIVER ADJUSTABLE OR FIXED
GENERAL SPECIFICATIONS
INPUT
Nominal Voltage:
Minimum Oper. Voltage:
Max. allowed voltage:
CONTACTS
Contact Material:
Rating:
The Series 236, 237 and 238 Time Delay Relay consists
of a standard 219 industrial relay and a solid state timing
module to provide delayed transfer of relay contacts after
application of power or activation of control switch. The
relay and timing module are enclosed in a flame resistant
polycarbonate cover.
INSULATION CHARACTERISTICS
Dielectric Strength:
Inverse polarity protection:
Typical Part Number
236 ABX P 020
Series
236 - ON DELAY
237 - OFF DELAY
238 - BATCH CONTROL INTERVAL
Contact Arrangements
ABX (DPDT & 1 N.O. Contact) 236 &
238 only).
XBX (DPDT)
120A
Silver Cadmium Oxide.
10 Amps @ 120 VAC res.
10 Amps @ 28 VDC
OPERATIONAL CHARACTERISTICS
Repeatability:
DC: ± 3%: @ 20˚C. AC: ± 3% +16 mS
Accuracy:
@ 20˚C.
Adjustable: ± 10% Within temperature
& voltage range. Fixed: ± 10% @ 25˚C
Min. waiting time before starting
next cycle (Reset Time):
100 mS (for timing cycle up to 60 sec.
150 mS for timing cycle 60 to 300 sec.
Insulation Resistance:
Transient Protection:
False Contacting:
Struthers-Dunn
AC: 24 to 240, DC: 12 to 125
AC - 85% of Nominal
DC - 80% of Nominal
110% of nominal voltage
500 V rms across open contacts,
1500 V rms between output contacts
and ground (Locking clip). (See note 4).
1000 Megohms min. @ 500 VDC.
5 mS, 0 to 2000 V 20 uSec peak
No false contacting if power is
interupted during timing.
DC operated are polarity protected. but
will not operate if polarity is reversed.
ENVIRONMENTAL CAPABILITIES
Ambient Temperature Rating:
- 10˚C to +70 ˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear Polycarbonate
8.6 oz approx. (244 g)
Mounting Options
P (Plug-in)
Timing Ranges
0.2 - 12 Sec - Code 012**
0.2 - 20 Sec - Code 020
2.0 - 200 Sec - Code 200
Adjustment Options
Adjustment Screw) - No Code
Fixed Delay - Specify Fixed Time & Code F *
Operating Voltage
AC; 24, 48, 120, 240 (Add "A" )
DC; 12, 24, 48, 115-125 (Add "D")
Code 012**- 12 Second timing not available on 237 & 238 models.
(F * Models) - timing code does not apply. Specify single delay time requirement.
Example of typical fixed time delay relay part number- 236XBXP-3.5F-120A
(ON DELAY, DPDT, 3.5 SEC FIXED, 120 VAC INPUT POWER).
NOTES:
1. 236,237,238 - External resistor (to program time delay) or jumper (for
built-in timing) must be connected to terminals 8 & 9.
2. 237 models require an external control switch between terminals 5 & 6.
3. 238 switches contacts when input power is applied and starts timing.
Contacts switch back to original position at end of timing cycle. Power must
be removed to reset timer. If input power is interupted during the timing
cycle, timing ends immediately and the relay resets.
4. Dielectric withstanding voltage testing of the Control circuit may damage
the solid state components.
PAGE 129
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
12 PIN, 10 AMP, TIME DELAY RELAY
236/237/238
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
Screwdriver adjust not
on fixed models.
.313
(7.95)
✝ TIMING * RESISTANCE CHART
3.75
(95.2)
236 RANGE: O.2 TO 12 SEC
20K OHMS PER EA.3 SEC
100 K OHMS MAX.
236 RANGE: 0.2 TO 20 SEC
100K OHMS PER EA.7 SEC
500 K OHMS MAX
237/238 RANGE: 0.2 TO 20 SEC.
100K OHMS PER EA.6 SEC
500 K OHMS MAX.
236 RANGE: 2.0 TO 200 SEC
200K OHMS PER EA.60 SEC
1 MEG OHM MAX.
237/238 RANGE: 2.0 TO 200 SEC
200K OHMS PER EA.55 SEC.
1 MEG OHM MAX.
4.56
(115.8)
LOCKING CLIP
* USE RESISTOR RATED 1/4 WATT
1
6
12
7
OR MORE.
1.468
(37.2)
2.625
(66.6)
EXAMPLE
WIRING DIAGRAMS
Viewed from Top of Relay
✝ Jumper or
External Resistor
12
6+
1
7-
INPUT
7TIMING
MODULE
TIMING
MODULE
237XBXP
236ABXP
ON DELAY
DOUBLE POLE DOUBLE
THROW WITH
NORMALLY OPEN CONTACT
✝ If the jumper wire shown in each
diagram is replaced by a resistor,
delay time will be added to that
which is produced by an internal
fixed resistor on fixed time models
(code F) or any setting on screwdriver
adjustable models. See timing resistance
chart above. Relay will not operate without
a jumper or resistor. Also see note 1.
OFF DELAY
6 +
1
External
control switch
DOUBLE POLE DOUBLE THROW
✝ Jumper or
External Resistor
7-
12
INPUT
12
INPUT
✝ Jumper or
External Resistor
TIMING
MODULE
BATCH CONTROL
INTERVAL
(SEE NOTE 3)
6+
1
DOUBLE POLE DOUBLE THROW
238XBXP
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 130
SERIES
246 & 247 INDUSTRIAL 10 AMP, ON-DELAY & OFF DELAY TIMER
SERIES 246 & 247
± 3% REPEATABILITY
OFF DELAY FUNCTION
PLUG-IN WITH SELF
LOCKING CLIP
1
UL Recognized
File No. 13224
TIME
MOD
6
12
Listed when used with
Type 29390 Socket
1
EXT. TRIGGER
6
12
R
.678
(17.2)
247XCXP
7
TIME
MOD
R
EXT. TRIGGER
Dimensions shown are in
INCHES and (millimeters)
3.75
(95.2)
247XBXP
7
4.56
(115.8)
Series 246 CSA Certified
ON DELAY FUNCTION
1
TIME
MOD
CONTACT LOAD SPECIFICATIONS
Make Carry Resistive Inductive
Voltage
10A
10A
10A
10A
10A
10A
10A
5A
10A
0.5A
7
1
6
10A
3A
1A
3A
0.1A
12
7
1
6
TIME
MOD
30A
30A
30A
30A
30A
12
TIME
MOD
The series 246 & 247 Time Delay Relays are
a ON-Delay or Off Delay Function times, with
timing ranges from 0.1 to 300 Seconds. The
246 Timer comes in either 2 - 4 poles, and
the 247 comes in 2 & 3 Pole models. Both
timers incorporate a class 219 relay along
with a Solid State timing module. Both timers
have a large choice of options and switch up
to 30 amp loads.
24 VDC
120 VAC
240 VAC
28 VDC
125 VDC
6
12
246BBXP
246XBXP
246ABAP
1
6
12
7
1.468
(37.2)
2.625
(66.6)
7
For Versions with suffix "69"
Permant Magnet Blowouts
125 VDC (SM)
125 VDC (DM)
250 VDC (SM)
250 VDC (DM)
30A
30A
30A
30A
10A
10A
10A
10A
1.5A
4A
0.5A
1.5A
0.5A
1.5A
150mA
0.5A
GENERAL SPECIFICATIONS SERIES 246 & 247 TIMER
INPUT
Coil Voltage
Minimum Operate Voltage:
Struthers-Dunn
Typical Part Number
247 XBX P L - 010
Series
246 - On Delay, Plug-in 2-4 Pole
247 - Off Delay, Plug-in, 2 & 3 Pole
Contact Arrangements
XBX (2 Form "C")
XCX (3 Form "C")
ABA (1 Form A & 2 Form C & 1 Form B).
BBX (2 Form A & 2 Form C) 246 Only.
Standard Features
Plug-in With Polycarbonate Cover - Code P
Options
Indicator Lamp- Code L
Manual Actuator - Code M
Bifurcated Contacts (5 Amps max) - Code 33
Permanent Magnet, Blowout Code 69
Timing Ranges
0.1 - 1.0 Sec - Code 001
0.2 - 2.0 Sec - Code 002
1.0 - 10 Sec - Code 010
3.0 - 30 Sec - Code 030
6.0 - 60 Sec - Code 060
18 - 180 Sec - Code 180
30 - 300 Sec - Code 300
Adjustment
Adjustment Knob) - No Code
Fixed - Timing Code does not apply. Ex. 3F = 3 Sec
Fixed) Code F
Remote Adj. (Ext Pot Required) - Code R
Operating Voltage
AC; 24, 48, 120, 240 (Add "A" )
DC; 12, 24, 48, 110-125 (Add "D")
PAGE 131
Max. allowed voltage:
- 120A
CONTACTS
Contact Material:
OPERATIONAL CHARACTERISTICS
Repeatability:
Accuracy:
Recycle Time:
False Contacting:
Polarity Protection:
INSULATION CHARACTERISTICS
Dielectric Strength:
All Mutually Insulated Points:
Transient Protection:
Insulation Resistance:
ENVIRONMENTAL CAPABILITIES
Ambient Temperature Rating:
LIFE EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Weight:
AC - 85% of Nominal
DC - 80% of Nominal
110% of nominal voltage
Silver Cadmium Oxide. - Gold Diffused
± 3% @ 25˚C (AC +16 mS)
Adjustable ± 10% Within temperature &
voltage range.
100 mS up to 60 Sec., 150 mS 60 to 300 Sec.
No false contacting if power is interrupted
during timing cycle.
DC inputs
500 V rms across open contacts
1500 V rms between current carrying
parts & Parts to Ground.
5 mS 0 to 2000V, 20 uSec peak
1000 MΩ min. @ 500 VDC
AC: -10˚C to +45˚C @ Rated Operation.
DC: -10˚C to +70 ˚C
10 Million Operations no load
100,000 Operations @ Rated Load.
500,000 @ 1/2 Rated Load.
Clear polycarbonate
8 oz. (227 g)
SEE SECTION 10
FOR
MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
ADJUSTABLE CURRENT SENSING RELAY
CLASS 235
CURRENT SENSOR
SPECIFICATIONS CLASS 235 CURRENT SENSOR
CURRENT SENSING:
Sense Current Range:
Repeatability:
1.5 to 15 Amperes
± 2% at constant Voltage & Temperature
± 10% over Voltage & Temperature Range.
15 mA (1.7 VA)
Input Current:
Current Sensor Resistance: 5 Milliohms
Temperature Range Operate: - 10˚C to + 55˚C
Temperature Range Storage: - 40˚C to + 85˚C
CONTACTS
Contact Combinations:
Contact Rating
Transient:
SPDT (1 Form C)
10 Amps @ 120 VAC, 6 Amps @ 28 VDC.
2000 V rms for 5 Microseconds
LIFE EXPECTANCY;
Electrical
Mechanical:
200,000 Operations @ Rated Load
5,000,000 Operations @ No Load
DIELECTRIC STRENGTH
Coil to Contacts:
Across Open Contacts:
2500 V rms
500 V rms
MECHANICAL
Terminals:
235
± 2 % REPEATABILITY
SPDT, 10 AMP CONTACTS
FIELD ADJUSTABLE CURRENT
SETTINGS.
Ul Recognized
File No. 62636
The Class 235 Current Sensing Relay
combines a Solid State Sensor with a
SPDT, 10 Amp relay. The Sensor is field
adjustable for detecting AC Current levels
in equipment. The sensor is non-latching
and has no time delay.
Choice of 1/4" or 3/16" Quick Connect
terminals.
6-32 Tapped Hole & anti rotation Tab or
Plug-in with 3/16" terminals.
Optional.
Polycarbonate dust cover.
4 oz. (113 g) approx.
Mounting:
Mounting Bracket:
Enclosure:
Weight:
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters)
WIRING DIAGRAM
SUPPLY
VOLTAGE
2.90 Max.
(73.8)
.312
(7.9)
1.53
(38.8)
1
2
3
4
5
6
1
4
2
5
3
6
7
8
9
7
8
9
.625
(15.8)
1.40
(35.7)
LOAD
B
A
A
B
INPUT
1.31
(33.3)
Continuous Voltage must
be supplied to Input.
.875
(22.2)
VIEWED FROM TERMINAL SIDE
ANTI-ROTATION TAB
SEE SECTION
10
FOR MATING SOCKETS
6-32 TAPPED HOLE
(1/4" Terminal Style)
PART NUMBERS
NOMINAL
INPUT
VOLTAGE
W235ACX-2
W235ACX-3
120 VAC
120 VAC
CURRENT
RANGE
TERMINAL
SIZE
1.5 to 15 Amps 1/4" (.250)
1.5 to 15 Amps 3/16" (.187)
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
NOTE: 3/16" (.187) TERMINALS ARE SOCKET MOUNTABLE.
1/4" (.250) TERMINALS, NO SOCKET AVAILABLE FOR THIS STYLE.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 132
SERIES
OVER/UNDER VOLTAGE SENSING, 10 AMP, 2-4 POLE
349
SERIES 349
FREQUENCY 50 to 400 Hz
PULL-IN ADJUSTABLE
BETWEEN 85 to 135 VAC
10 AMP CONTACTS
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
Differential 4.0 volts ±
1 Volt nonadjustable
.313
(7.95)
1
7
RESISTOR
1
A
CONTACT LOAD SPECIFICATIONS
Make Carry Resistive Inductive
Voltage
10A
10A
5A
10A
0.5A
B
C
N RESISTOR
6
10A
3A
1A
3A
0.1A
SENSING MODULE
12
30A
30A
30A
30A
10A
10A
10A
10A
1.5A
4A
0.5A
1.5A
1
6
12
7
1.468
(37.2)
7
THREE PHASE -349XBXP
For Versions with suffix "69"
Permanent Magnet Blowouts
125 VDC (SM)
125 VDC (DM)
250 VDC (SM)
250 VDC (DM)
INPUT
7
1
10A
10A
10A
10A
10A
4.56
(115.8)
6
SINGLE PHASE -349ABXP
349 ABXP & XBXP Style the
Differential Adjustment is
Externally Adjustable from 3
to 14 Volts.
30A
30A
30A
30A
30A
3.75
(95.2)
SINGLE PHASE -349BBXP
12
24 VDC
120 VAC
240 VAC
28 VDC
125 VDC
INPUT
SENSING
MODULE
12
SENSING
MODULE
The Series 349 Under/Over Voltage Sensing
Relay incorporates a Series 219 relay and an
Electronic Module. Pull-in Voltage is adjustable
between 85 and 135 VAC for frequencies from
50 to 400 Hz. Models available for Single and
Three Phase sensing with differential (between
pull-in and Dropout) Adjustable from 2 to 14 Volts
by external fixed or adjustable resistor. Single
Phase relays are also available with standard 3
volt fixed differential and other fixed values up to
14 volts, on special order.
6
0.5A
1.5A
150mA
0.5A
2.625
(66.6)
Struthers-Dunn
Typical Part Number
349 BBX
Series
349 Sensor -Plug-in, Over/Under
Voltage Relay, 10A, 2 -4 poles
P L33- 85-135A
GENERAL SPECIFICATIONS SERIES 349 SENSOR
INPUT
Module Voltage:
AC Current Drain:
CONTACTS
Contact Material:
Adjustment 85 to 135 VAC, 50 to 400 Hz
De-energized -15 mA, Energized - 50 mA
Silver Cadmium Oxide. - Gold Diffused
OPERATIONAL CHARACTERISTICS
25 Milliseconds
Operate time:
25 Milliseconds
Release Time:
INSULATION CHARACTERISTICS
Dielectric Strength
Across Open Contacts:
All Mutually Insulated Points:
Insulation Resistance
500 V rms
1500 V rms
1000 Megohms min. @ 500VDC.
ENVIRONMENTAL CAPABILITIES
Ambient Temperature Rating:
-10˚C to +60˚C @ Rated Operation.
LIFE EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Weight:
PAGE 133
20 Million Operations no load
100,000 Operations @ Rated Load.
500,000 @ 1/2 Rated Load.
Clear polycarbonate
10 oz. (284 g)
Contact Arrangement & Function
BBX - 2 Form A & 2 Form C, (Single Phase)
4V ± 1V Fixed.
ABX - 1 Form A & 2 Form C, (Single Phase)
Ext. Adjustment, 3 to 14V
XBX - 2 Form C, (3 Phase)
External Adjustment, 3 to 14V
Standard Features
Plug-in With Polycarbonate Cover - Code P
Options
Indicator Lamp- Code L
Manual Actuator - Code M
Bifurcated Contacts (5 Amps max) - Code 33
Permanent Magnet, Blowout Code 69
Operating Voltage
AC; 85 to 135 (Add "A" )
DC; Consult Factory
Note: For non-Standard Differential Consult Factory
SEE SECTION 10
FOR
MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
ADJUSTABLE VOLTAGE SENSING RELAY
The Class 236 Voltage Sensing Relay combines a Solid State Sensor
with a SPDT, 13 Amp or DPDT 10 Amp relay.
The Sensor is field adjustable for Pull-in & Dropout .
The 236 can be used either as a over or under voltage detecting relay.
The sensor is non-latching and has no time delay.
Applications: Brownout protection, warning of under voltage conditions
and Over voltage protection. Prevents equipment burnout.
CLASS
236
CLASS 236
VOLTAGE SENSOR
Ul Recognized
File No. 62636
SPECIFICATIONS CLASS 236 CURRENT SENSOR
VOLTAGE SENSING:
Nominal Input:
±1 % REPEATABILITY
SPDT, 13 AMP CONTACTS
FIELD ADJUSTABLE
120,240,480 VAC 50/60Hz, 24VAC, 24 VDC. Other
AC & DC Voltages Available.
Pull-in 75% to 115% of Nominal Voltage.
Adjustment Range:
Dropout 75% to 95% of Pickup setting.
± 1% @ constant Voltage & Temperature
Repeatability:
15 mA (1.7 VA)
Input Current:
Relay "Off" 2 mA max. Relay "On" 22 mA max. @ 120AC (2.7 VA)
Current Sensor Resistance:
12 mA 240AC max. (2.9VA), 7 mA max. 480 AC (3.41 VA)
Temperature Range Operate: - 30˚C to + 55˚C
Temperature Range Storage: - 40˚C to + 85˚C
CONTACTS
Contact Combinations:
Contact Rating
Contact Life Electrical:
Contact Life Mechanical:
Transient:
Noise Immunity:
SPDT (1 Form C), DPDT (2 Form "C")
SPST: 13 Amps @ 240 VAC, 28 VDC Res.
1/3 HP @ 120 VAC, 1/2 HP @ 240/480 AC,
3 AMPS @ 480 VAC, NEMA B300 Pilot Duty
DPDT: 10 AMPS @ 240 VAC/28 VDC Res.
1/3Hp @ 120 VAC, 1/2 Hp 240 VAC
NEMA B300 Pilot Duty.
SPDT: 100,000 Operations @ 13 Amps, 240AC Res.
DPDT: 100,000 Operations @ 10 Amps, 240AC Res.
SPDT:5,000,000 Operations
DPDT: 50,000,000 Operations.
UL 508 Surge 5000 V for 50 microseconds
NEMA ICS2-230, 2500 VAC
DIELECTRIC STRENGTH
Breakdown:
Coil to Contacts:
Across Open Contacts:
UL 508 Surge 5KV 1.2 x 50 Microseconds.
2500 V rms
1000 V rms
MECHANICAL
Terminals:
Enclosure:
Power "ON" Indicator:
Weight:
3/16" (.187) Quick Connect terminals. or 8 Pin Octal base
Polycarbonate dust cover.
L.E.D. ( Green)
4 oz. 124.4 g,
5 oz 155.5g (8 pin octal)
±1 % REPEATABILITY
DPDT, 10 AMP CONTACTS
FIELD ADJUSTABLE
SEE SECTION 10
FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 134
CLASS
ADJUSTABLE VOLTAGE SENSING RELAY
236
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters)
WIRING DIAGRAMS
2
3
4
5
6
7
8
1
4
2
5
3
6
7
8
9
L.E.D
1
2.90 Max.
(73.8)
.312
(7.9)
1.53
(38.8)
VIEWED FROM PIN END
FIGURE "B"
1.40
(35.7)
9
A
B
B
A
INPUT
L.E.D
L.E.D
Dropout
Pull-in
SQUARE BASE
Continuous Voltage
must be supplied to Input.
Screw Driver Adjustable with
Graduated scale.
OUTLINE DIMENSIONS
Dimensions are Shown In Inches and (Millimeters)
.562 (14.2)
L.E.D
WIRING DIAGRAMS
VIEWED FROM PIN END
FIGURE "A"
▼
▲
2.93
(74.4)
▼
▲
4
5
6
3
2
7
1
+
8
INPUT
2.37
(60.3)
8 PIN OCTAL
Continuous Voltage
must be supplied to Input.
7
6
5
8
4
1
3
PART NUMBERS
FIG.
W236ACX-1
W236ACX-2
W236ACX-4
B
B
B
W236ACPX-1
W236ACPX-4
W236CPX-1
A
A
A
NOMINAL
INPUT
VOLTAGE
VOLTAGE
PULL-IN
RANGE
VOLTAGE
DROP-OUT
RANGE
120 VAC
90 to 138 VAC 75% to 95%
208/220 240 VAC 180 to 276 VAC of Pickup
Voltage
480 VAC
360 to 552 VAC
Setting
120 VAC
24 VAC
24 VDC
92 to 140 VAC 90 to 138 VAC
20 to 30 VAC 18 to 28VAC
20 to 30 VDC 18 to 28 VDC
1.75
(44.4)
2
CROSS REFERENCE
TO
POTTER & BRUMFIELD
CSJ-38-70010
CSJ-38-30010
CSL-38-30010
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 135
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N
6
6
POWER RELAYS
AND
CONTACTORS
15 TO 200 AMPERES
Page 136
Magnecraft
Struthers-Dunn
POWER RELAYS & CONTACTORS
RELAY SERIES
199
425
88UKD
415
QUALIFIED
FEATURES
PANEL MOUNT, OPEN
STYLE CONSTRUCTION
MULTI CONTACT
CONFIGURATIONS UP
TO 50 AMPS SWITCHING.
MAGNETIC BLOWOUT
FOR DC SWITCHING
COMPACT OPEN STYLE
PANEL MOUNT OPEN
STYLE CONSTRUCTION RELAY WITH 6-32 TAPPED
HOLE & ANTI-ROTATION
3PDT CONTACT
TAB FOR PANEL MOUNT.
CONFIGURATIONS
UP TO 30 AMP SWITCH- SWITCHES UP TO 3O
ING
AMPS
SCREW TERMINALS
PANEL MOUNT, COMPACT
SIZE, OPEN STYLE CONSTRUCTION.
MULTI CONTACT
CONFIGURATIONS.
SCREW TERMINALS.
1/4" SPADE LUG TERMIINSULATED ARMATURE NALS
TO 600V AVAILABLE
DOUBLE MAKE CONTACTS
OPTIONAL HIGH VOLTAGE
AND HIGH INRUSH CONTACTS, Q.C. TERMINALS,
MAGNET BLOWOUT.
SPECIAL LOW POWER
COILS AVAILABLE.
SEE CATALOG PAGE
30 AMPS UP TO 300
VAC, 28 VDC, (STD.)
BOX TERMINAL
SPST-DM -UP TO 50A.
WITH MAGNETIC
BLOWOUT UP TO
20AMP DC
3PDT
25 AMP @120-240VAC
17AMP @ 277VAC
10AMP @ 600VAC
30AMP @ 30VDC
SPST-N.0. (DM)
SEE CATALOG PAGE
15 AMPS @ 120VAC 1/2HP
10 AMPS @ 240VAC 1HP
15 AMPS @ 30VDC
CONTACT MATERIAL:
SILVER CADMIUM OXIDE,
SILVER CADMIUM OXIDE
CONTACT RESISTANCE:
50 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
SILVER ALLOY
GOLD FLASHED
50 MILLIOHMS (INITIAL)
2200 V rms
2500 V rms
CLASS "B" INSULATION
SYSTEM
SCREW & BOX TERMINALS
CONTACT DATA
CONTACT CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
30 AMPS @
300VAC/28VDC
5 AMPS 600VAC
SILVER CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH
3000 V rms
1500 V rms
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER
VA,: (VAC)
WATTS,: (VDC)
24, 120 & 240 VAC
6, 12, 24, 110 VDC
6 to 480 VAC
6 to 220 VDC
24, 120 & 240 VAC
12, 24 & 110 VDC
10 VA
2.0 WATTS
11 VA
4.0 WATTS
3 VA
1.5 WATTS
STORAGE:
TIMING VALUES
OPERATE:
RELEASE:
- 30˚ C to + 50˚ C (AC.)
- 30˚ C to + 60˚ C (DC)
- 30˚ C to + 100˚ C
40 MILLISECONDS
35 MILLISECONDS
- 55˚ C to + 45˚ C (AC)
- 55˚ C to + 80˚ C (DC)
LIFE
MECHANICAL:
ELECTRICAL:
5 MILLION OPERATIONS
100,000 OPERATIONS
10 MILLION OPERATIONS
100,000 OPERATIONS
6 to 240 VAC
6 to 125 VDC (Use
power resistor for 250VDC)
6VA
3.5 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
DIMENSIONS
D
W
L
2.53 X 2.50 X 2.43-3.12
- 10˚ C to + 50˚ C (AC)
- 10˚ C to + 60˚ C (DC)
25 MILLISECONDS
10 MILLISECONDS
30 MILLISECONDS
15 MILLISECONDS
D W
L
2.30 X 2.50 X 3.24
- 45˚ C to + 55˚ C
- 45˚ C to + 55˚ C
5 MILLION OPERATIONS
100,000 OPERATIONS
D
W
L
.1.40 X 1.25 X 1.93
AC- 50M, - DC-100M OPER'S.
200,000 OPERATIONS
D
W
L
1.75 X 1.87 X 2.75
APPROVALS
PAGE NUMBER
PAGE 137
PAGE 140 THRU 146
PAGE 147
PAGE 148
PAGE 149, 150
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
CONTACTORS
103
275
575
2 COIL, COMPACT MOTOR
REVERSING CONTACTOR.
2 COIL, MOTOR REVERSING CONTACTOR
1/4" DUAL Q.C. TERMINALS
WITH UP TO 4 OPTIONAL
AUXILIARY SWITCHES.
MECHANICAL INTERLOCK CHOICE OF CONTACT
CONFIGURATIONS
COILS
CHOICE OF CONTACT
CONFIGURATIONS
CHOICE OF CONTACT
CONFIGURATIONS
RATED UP TO 50 AMPS
SCREW TERMINALS WITH CONTINUOUS
OPTIONAL 5A AUXILIARY
CONTACTS ENCLOSED
SWITCHES AVAILABLE.
WITH MOLDED PLASTIC
COVER.
RATED UP TO 7.5 HP
RATED UP TO 100 AMPS
CONTINUOUS
RATED UP TO 200 AMPS
CONTINUOUS
CONTACTS ENCLOSED
WITH MOLDED PLASTIC
COVER.
CONTACTS ENCLOSED
WITH MOLDED PLASTIC
COVER.
AC COILS AVAILABLE
AC COILS AVAILABLE
ENCAPSULATED COIL
USED FOR AC OR DC MODELS
MECHANICAL INTERLOCK,
CENTER OFF WHEN BOTH
COILS NOT ENERGIZED.
6 POLE-DM (3 PER COIL)
15 AMPS @120VAC/1HP
10AMPS @ 240VAC/1.5HP
5AMPS @ 480/600/3HP
15AMPS @ 30VDC
5AMPS @ 125VDC
1AMP @ 250VDC
102
101
HEAVY DUTY DC SOLENOID HEAVY DUTY DC SOLENOID
STYLE CONTACTOR.
STYLE CONTACTOR.
AC COILS AVAILABLE
6 POLE-DM (3 PER COIL)
30 AMPS @120 VAC, 1.5HP
30 AMPS @240VAC, 3HP
15 AMPS @480 VAC, 7.5HP
15 AMPS @600 VAC, 7.5HP
15 AMPS @ 115VDC
2 AMPS @ 230 VDC
SEE CATALOG PAGE
50 AMPS @
120/240VAC,
30 VDC
SEE CATALOG PAGE
HEAVY DUTY DC SOLENOID
STYLE CONTACTOR.
SEE CATALOG PAGE
200 AMPS @
120/240VAC,
30 VDC
100 AMPS @
120/240VAC,
30 VDC
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
100 MILLIOHMS (INITIAL)
100 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
2500 V rms
2500 V rms
1500 V rms
12 to 240 VAC
12 to 120 VDC
24 to 550VAC
12 to 240 VDC
12, 28, 48 VDC
12, 28, 48 VDC
12, 28, 48 VDC
16.7 VA
4.9 WATTS
22 VA
10 WATTS
9 WATTS
11.6 WATTS
14 WATTS
- 45˚ C to + 50˚ C (AC)
- 45˚ C to + 70˚ C (DC)
- 40˚ C to + 50˚ C (AC)
- 40˚ C to + 50˚ C (DC)
- 45˚ C to + 65˚ C (DC)
50 MILLISECONDS
30 MILLISECONDS
60 MILLISECONDS
30 MILLISECONDS
500,000 OPERATIONS
100,000 OPERATIONS
500,000 OPERATIONS
100,000 OPERATIONS
D
W
L
D
W
L
2.75 X 2.985 6 X 3.62
3.00 X 5.25 X 4.43
PAGE 151, 152
PAGES 153, 154
1500 V rms
1500 V rms
- 45˚ C to + 65˚ C (DC)
- 45˚ C to + 65˚ C (DC)
60 MILLISECONDS
30 MILLISECONDS
60 MILLISECONDS
30 MILLISECONDS
60 MILLISECONDS
30 MILLISECONDS
500,000 OPERATIONS
100,000 OPERATIONS
500,000 OPERATIONS
100,000 OPERATIONS
500,000 OPERATIONS
100,000 OPERATIONS
D
W
L
1.84 X 2.34 X 2.50
PAGES 155, 156
D
W
L
D
W
L
2.09 X 3.12 X 3.00
2.65 X 4.25 X 3.00
PAGES 155, 156
PAGES 155, 156
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 138
Magnecraft
Struthers-Dunn
POWER , GFI AND MDR RELAYS
RELAY SERIES
FEATURES
214 (GFI)
SMALL OPEN STYLE
GROUND FAULT INTERRUPT RELAY.
MAX. OVER LOAD 120
AMPS @ 120VAC
102, 103
MDR
MERCURY DISPLACEMENT RELAY
(MDR)
UP TO 3 POLES, NO OR NC &
COMBINATIONS OF NO & NC
ENCAPSULATED COIL..
PIERCED SOLDER LUG
TERMINALS WITH #17
AWG SILICONE WIRE
UP TO 100 AMPS SWITCHING
MOUNTING WITH 6-32
TAPPED HOLE & ANTIROTATION TAB
PANEL MOUNTED VERTICAL
± 15˚
LOW CONTACT RESISTANCE
HEAVY DUTY DC SOLENOID STYLE
LIGHTING CONTACTOR, MOUNTS TO
WATT HOUR METER ENCLOSURE.
DPST-NO-DM CONTACT CONFIGURATION.
RATED UP TO 50 & 100 AMPS CONTINUOUS DUTY.
CONTACTS ENCLOSED IN MOLDED
PLASTIC COVER.
DC COILS AND AC FULL WAVE
RECTIFIED COILS.
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
DPDT (2 FORM C)
20 AMPS @ 120/240VAC
20 AMPS @ 30 VDC
120AMPS @ 120VAC
(10 CYCLES)
SILVER, CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
1 to 3PST-NO or NC
35 TO 100 AMPS @
120-480VAC.
25-50 AMPS @ 600VAC
100 AMPS, 24-48 VDC
80 AMPS, 120VDC
MERCURY
DPST-NO-DM
50 & 100 AMPS @
120/240VAC,
30 VDC
SILVER CADMIUM OXIDE
2 MILLIOHMS
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH:
2000 V rms
2650 V rms
1500 V rms
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER
VA, (VAC):
WATTS, (VDC):
6, 12, 24, 120 VAC
6, 12, 24, 110-125 VDC
-
12 to 240 VAC
6 to 220 VDC
120 & 240 VAC
24 VDC
20 WATTS
33 VA
9 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
TIMING VALUES
OPERATE:
RELEASE:
LIFE
MECHANICAL:
ELECTRICAL:
DIMENSIONS
- 45˚ C to + 65˚ C
- 35˚ C to + 60˚ C
15 MILLISECONDS
15 MILLISECONDS
50 MILLISECONDS
100 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
5 MILLION OPERATIONS
100,000 OPERATIONS
- 45˚ C to + 65˚ C (DC)
D
W
L
1.37 X 1.00 X 2.10
D
W
L
3.36 X 3.75 X 5.06
60 MILLISECONDS
30 MILLISECONDS
500,000 OPERATIONS
100,000 OPERATIONS
D
W
L
3.0 X 6.0 X 6.0
APPROVALS
GENERAL SPECIFICATIONS & APPLICATION DATA:
PAGE NUMBER
PAGE 139
PAGE 157
PAGE 158, 159
PAGE 160 THRU 164
PAGES 165
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OPEN STYLE 30 AMP POWER RELAY
CLASS
199
CLASS 199 SPDT
UL Listed
File No. E43641
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
30 AMP - 1-1/2 Hp
CLASS "B" COIL
INSULATION SYSTEM
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.18 Max.
(55.37)
UP
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
.375
(9.5)
2.50
(63.5)
1.87
(47.5)
0.187 Dia.
(2 Places)
1.62
41.14
2.43 Max.
(61.7)
SPECIFICATIONS CLASS 199
COIL
Pull-in Voltage:
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
CONTACTS
Contact Combination:
Contact Rating
Contact Material:
TIMING
Operate time:
Release Time:
DIELECTRIC STRENGTH
Between Open Contacts:
Mutually Insulated
Conductive elements:
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
LIFE
Electrical (Rated Load):
Mechanical (No Load):
MISCELLANEOUS
Coil Terminals:
Contact Terminals:
Base Material:
Weight:
80% DC Coils, 85% AC coils of
nominal voltage or Less @ 25˚C
10% of Nominal Voltage or More @ 25˚C
± 10% @ 25˚C
DC Coils-4 Watts Max. Continuous.
SPDT
30 Amps up to 300VAC, 50/60Hz
5 Amps @ 480/600 VAC, 50/60HZ
0.75pF Inductive Load. 1-1/2 HP Motor
Load @ 120 thru 600 VAC, 50/60 Hz.
30 Amps @ 28 VDC Resistive Load
NEMA A 600 Pilot Duty 50/60Hz
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
40 Milliseconds Max. @ Nominal V
30 Milliseconds Max. @ Nominal V
1500 V rms
2200 V rms
PART
NUMBERS
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
-30˚C to +100˚C
100,000 Operations
5,000,000 Operations
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL Recognized
(QMFZ2)
8 oz. - 227 Grams approx. (SPDT)
COIL Measured @ 25˚C
NOMINAL NOMINAL
NOMINAL
RESISPOWER
INPUT
TANCE
VOLTAGE
(OHMS)
AC OPERATED (SPDT)
120 VAC
W199AX-4
DC OPERATED (SPDT)
12 VDC
W199X-2
24 VDC
W199X-3
CROSS
REFERENCE
POTTER &
BRUMFIELD
-
10 VA
PRD5AGO-120
70
290
2.0 W
2.0 W
PRD5DGO-12
PRD5DGO-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 140
CLASS
OPEN STYLE 30 AMP POWER RELAY
199
CLASS 199 DPDT
30 AMP - 1-1/2 Hp
CLASS "B" COIL
INSULATION SYSTEM
UL Listed
File No. E43641
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.31 Max.
(58.67)
UP
2.50
(63.5)
1.87
(47.5)
0.187 Dia.
(2 Places)
.375
(9.5)
COIL
Pull-in Voltage:
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
COIL Measured @ 25˚C
CROSS
NOMINAL
NOMINAL NOMINAL REFERENCE
RESIS- POWER
INPUT
POTTER &
TANCE
VOLTAGE
BRUMFIELD
(OHMS)
AC OPERATED (DPDT)
24 VAC
W199AX-13
120 VAC
W199AX-14
240 VAC, 60 Hz
W199AX-15
220 VAC, 50 Hz
-
10 VA
10 VA
-
10 VA
PRD11AGO-24
PRD11AGO-120
PRD11AGO-240
DC OPERATED (DPDT)
W199X-11
W199X-12
W199X-13
W199X-14
6 VDC
12 VDC
24 VDC
110 VDC
18
70
290
6000
2.0 W
2.0 W
2.0 W
2.0 W
PRD11DGO-6
PRD11DGO-12
PRD11DGO-24
PRD11DGO-110
RECTIFIED, AC OPERATED (DPDT)
W199AXD-38 ✝ 208, 240, 277 VAC
-
See Note ✝✝
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
✝
✝✝
Built in Coil Diodes provide a wide range of Nominal Coil input
voltages. This relay is suitable to Operate within a range of
208 Vac thru 277 Vac.
208 Vac = 2.3 VA, 240 Vac = 3.0 VA, 277 Vac = 4.0 VA.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
80% DC Coils, 85% AC coils of
nominal voltage or Less @ 25˚C
10% of Nominal Voltage or More @ 25˚C
± 10% @ 25˚C
DC Coils-4 Watts Max. Continuous.
CONTACTS
DPDT
Contact Combinations:
Contact Rating each Pole: 30 Amps up to 300VAC, 50/60Hz
5 Amps @ 480/600 VAC 50/60Hz, 0.75pF
Inductive Load. 1-1/2 HP Motor Load (each
Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP
Motor Load @ 200 thru 600 VAC, 50/60 Hz
only when using two poles to switch both
sides of Load.
30 Amps @ 28 VDC Resistive Each Pole.
NEMA A600 Pilot Duty 50/60HZ
Contact Material:
TIMING
Operate time
Release Time:
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
40 Milliseconds Max. @ Nominal V
30 Milliseconds Max. @ Nominal V
DIELECTRIC STRENGTH
Between Open Contacts: 1500 V rms
Mutually Insulated
2200 V rms
Conductive elements:
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
LIFE
Electrical (Rated Load):
Mechanical (No Load):
100,000 Operations
5,000,000 Operations
MISCELLANEOUS
Coil Terminals: l
Contact Terminals:
Base Material:
Weight:
PAGE 141
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
SPECIFICATIONS CLASS 199
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
PART
NUMBERS
1.62
3.12 (41.1)
(79.2)
-30˚C to +100˚C
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL Recognized
(QMFZ2)
11 oz. - 311 Grams approx. (DPDT)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
OPEN STYLE POWER RELAY
199
CLASS 199 DPST-NO
UL Listed
File No. E43641
*
1-1/2 HP PER POLE
2 Hp - 2 POLE SWITCHING
CLASS "B" COIL
INSULATION SYSTEM
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.25 Max.
(57.15)
UP
.375
(9.5)
2.50
(63.5)
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
1.87
(47.5
0.187 Dia.
(2 Places)
1.62
41.14
2.43 Max.
(61.7)
SPECIFICATIONS CLASS 199
COIL
Pull-in Voltage:
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
80% DC Coils, 85% AC coils of
nominal voltage or Less @ 25˚C
10% of Nominal Voltage or More @ 25˚C
± 10% Measured @ 25˚C
DC Coils-4 Watts Max. Continuous.
CONTACTS
Contact Combinations:
DPST-NO
Contact Rating each Pole: Each pole rated 30 Amps up to 300 VAC,
50/60Hz, 5 Amps @ 480/600VAC ,0.75pF
Inductive load. 1-1/2 HP Motor Load (each
Pole) @ 120 thru 600 VAC, 50/60 Hz. 2 HP
Motor Load @ 200 thru 600 VAC, 50/60
Hz only when using two pole to switch both
sides of Load 30 Amps @ 28 VDC Resistive
load each Pole.
NEMA A600 Pilot Duty 50/60Hz
Contact Material:
TIMING
Operate time
Release Time:
COIL Measured @ 25˚C
NOMINAL NOMINAL
NOMINAL
RESISPOWER
INPUT
TANCE
VOLTAGE
(OHMS)
PART
NUMBERS
40 Milliseconds Max. @ Nominal V
35 Milliseconds Max. @ Nominal V
AC OPERATED (DPST-NO)
DPST-NO
W199AX-8
24 VAC
W199AX-9
120 VAC
W199AX-10 240 VAC, 60 Hz
220 VAC, 50 Hz
-
10 VA
10 VA
-
10 VA
CROSS
REFERENCE
POTTER &
BRUMFIELD
PRD7AGO-24
PRD7AGO-120
PRD7AGO-240
DC OPERATED (DPST-NO)
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
LIFE
Electrical (Rated Load):
Mechanical (No Load):
100,000 Operations
5,000,000 Operations
Weight:
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
DIELECTRIC STRENGTH
Between Open Contacts: 1500 V rms
Mutually Insulated
Conductive elements:
2200 V rms
MISCELLANEOUS
Coil Terminals:
Contact Terminals:
Base Material:
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
-30˚C to +100˚C
W199X-7
W199X-8
12 VDC
24 VDC
70
290
2.0 W
2.0 W
PRD7DGO-12
PRD7DGO-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL Recognized
(QMFZ2)
9 oz. - 255 Grams approx... (DPST-NO)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 142
C L A SS
OPEN STYLE POWER RELAY
199
CLASS 199DB
SPST-NO-DM WITH
UL Listed
MAGNETIC BLOWOUT File No. E43641
FOR DC ARC QUENCING
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
MAGNETIC
Blowout
2.18 Max.
(55.4)
2.50
(63.5)
UP
.375
(9.5)
1.87
(47.5)
0.187 Dia.
(2 Places)
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
1.62
41.14
2.43 Max.
(61.7)
0.10
(2.54)
SPECIFICATIONS CLASS 199
COIL
Pull-in Voltage:
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
CONTACTS
Contact Combinations:
Contact Rating :
Additional Ratings, with
Blowout Magnet for DC
switching:
Contact Material:
80% DC Coils, 85% AC coils of
nominal voltage or Less @ 25˚C
10% of Nominal Voltage or More @ 25˚C
± 10% Measured @ 25˚C
DC Coils-4 Watts Max. Continuous.
SPST-NO-DM Double Make
30 Amps up to 300 VAC, 50/60Hz, 5 Amps
@ 480/600Vac,0.75pFInductive Load.
1-1/2 HP Motor Load (each Pole) @ 120 thru
600 VAC, 50/60 Hz.
2 HP Motor Load @ 200 thru 600 VAC, 50/60 Hz
only when using two poles to switch .
30 Amps @ 28 VDC Resistive Each Pole.
NEMA A600 Pilot Duty 50/60Hz
20 Amps @ 110 VDC, Resistive; 8 Amps at 220 VDC,
Resistive, 4 Amps @ 325VDC Resistive. 2 amps @
500 VDC resistive. For Inductive Loads, contacts
must be derated accordingly. Capacitive loads must
be limited to insure that inrush current will not exceed
100 Amps.
TIMING
Operate time:
Release Time:
40 Milliseconds Max. @ Nominal V
30 Milliseconds Max. @ Nominal V
DIELECTRIC STRENGTH
Between Open Contacts: 1500 V rms
Mutually Insulated
Conductive elements:
2200 V rms
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
-30˚C to +100˚C
LIFE
Electrical (Rated Load):
Mechanical (No Load):
100,000 Operations
5,000,000 Operations
MISCELLANEOUS
Coil Terminals:
Contact Terminals:
Base Material:
Weight:
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL Recognized (QMFZ2)
8 oz. - 227 Grams approx. (SPST-NO-DM)
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
COIL Measured @ 25˚C
CROSS
NOMINAL NOMINAL NOMINAL REFERENCE
RESISPOWER POTTER &
INPUT
BRUMFIELD
VOLTAGE TANCE
(OHMS)
AC OPERATED (SPST-NO-DM WITH MAGNETIC BLOWOUT)
PART
NUMBER
W199ADBX-4 120 VAC
-
10 VA
PRD3AJ0-120
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
PAGE 143
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DOUBLE MAKE OR BREAK POWER RELAYS
UL Listed
File No. E43641
199
CLASS 199 SPST-NC-DB
OR SPST-NO-DM
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
*
CLASS
RATED 30 AMPS @ 2 HP
CLASS "B" COIL
INSULATION SYSTEM
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
2.25 Max.
(57.15)
1.87
2.50 (47.5)
(63.5)
0.187 Dia.
(2 Places)
SPST-NC-DB
UP
.375
(9.5)
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
1.62
41.14
2.43 Max.
(61.7)
0.10
(2.54)
SPECIFICATIONS CLASS 199
COIL
Pull-in Voltage:
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
CONTACTS
Contact Combinations:
80% DC Coils, 85% AC coils of
nominal voltage or Less. @ 25˚C
10% of Nominal Voltage or More @ 25˚C
± 10% @ 25˚C
DC Coils-4 Watts Max. Continuous.
SPST-NC (Double Break
SPST-NO (Double Make
Contact Rating SPST-NO-DM:
30 Amps up to 300 VAC, 50/60Hz
12 Amps @ 480, 10 Amps @ 600VAC,50/60
0.75pFInductive Load. 2 HP Motor Load
@ 120 thru 600 VAC, 50/60 Hz. 30 Amps
@ 28 VDC Resistive load.
NEMA A600 Pilot Duty 50/60Hz
:Contact Material:
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
TIMING
Operate time
Release Time:
40 Milliseconds Max. @ Nominal V
30 Milliseconds Max. @ Nominal V
DIELECTRIC STRENGTH
Between Open Contacts:
Mutually Insulated
Conductive elements:
1500 V rms
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
LIFE
Electrical (Rated Load):
Mechanical (No Load):
MISCELLANEOUS
Coil Terminals:
Contacts Terminals:
Base Material:
Weight:
2200 V rms
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
-30˚C to +100˚C
100,000 Operations
5,000,000 Operations
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL recognized
(QMz2)
8 oz. - 227 Grams approx.
SPST-NO-DM
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
COIL Measured @ 25˚C
CROSS
NOMINAL NOMINAL REFERENCE
RESISPOTTER &
POWER
TANCE
BRUMFIELD
(OHMS)
DC OPERATED (SPST-NC-DB WITH 30 AMP SCREW TERMINALS)
PRD4DG0-12
70
2.0 W
W199DYX-2
12 VDC
AC OPERATED (SPST-NO-DM WITH 30 AMP SCREW TERMINALS)
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
W199ADX-4
120 VAC
W199ADX-5 240 VAC, 60 Hz
220 VAC, 50 Hz
-
10 VA
-
10 VA
PRD3AG0-120
PRD3AG0-240
DC OPERATED (SPST-NO-DM WITH 30 AMP SCREW TERMINALS)
W199DX-2
W199DX-3
12 VDC
24 VDC
70
290
2.0 W
2.0 W
PRD3DG0-12
PRD3DG0-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 144
CLASS
DOUBLE MAKE POWER RELAYS
199
CLASS 199 SPST-NO-DM
RATED 50 AMPS - 2HP
WITH BOX TERMINALS.
CLASS "B" COIL
INSULATION SYSTEM
S
BO HOW
X T NW
I
ER
MIN TH
AL
S
UL Listed
File No. E43641
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
OUTLINE DIMENSIONS
Dimensions shown in Inch & (Millimeters)
50 AMP BOX TERMINALS ACCEPT
NO.14 THRU NO. 6 AWG. WIRE
Box
Terminal's
2.18 Max.
(55.4)
.375
(9.5)
UP
2.50
(63.5)
1.87
(47.5)
1.62
41.14
VERTICAL MOUNTING
2.43 Max.
(61.7)
3.50 Max.
(88.9)
0.187 Dia.
(2 Places)
0.10
(2.54) RECOMMENDED WITH
CONTACTS UP
SPECIFICATIONS CLASS 199
COIL
Pull-in Voltage:
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
COIL Measured @ 25˚C
CROSS
NOMINAL NOMINAL NOMINAL REFERENCE
RESISPOTTER &
INPUT
POWER
TANCE
BRUMFIELD
VOLTAGE (OHMS)
AC OPERATED (SPST-NO-DM WITH 50 AMP BOX TERMINALS)
PART
NUMBERS
W199ADEX-4
120 VAC
-
10 VA
PRD3AP4-120
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
CONTACTS
Contact Combinations:
80% DC Coils, 85% AC coils of
nominal voltage or Less. @ 25˚C
10% of Nominal Voltage or More @ 25˚C
± 10% @ 25˚C
DC Coils-4 Watts Max. Continuous.
SPST-NO Double Make
Contact Ratings :
50 Amps up to 300 VAC, 50/60Hz
50 Amps @ 28 VDC Resistive load. Loads
must be current limited as not to exceed
100 Amp inrush Currents.
NEMA A600 Pilot Duty 50/60Hz
Contact Material:
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
TIMING
Operate time
Release Time:
40 Milliseconds Max. @ Nominal V
30 Milliseconds Max. @ Nominal V
DC OPERATED (SPST-NO-DM WITH 50 AMP BOX TERMINALS)
W199DEX-3
24 VDC
290
2.0 W
PRD3DP4-24
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
DIELECTRIC STRENGTH
Between Open Contacts:
Mutually Insulated
Conductive elements:
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
LIFE
Electrical (Rated Load):
Mechanical (No Load):
MISCELLANEOUS
Coil Terminals:
Contacts Terminals:
Base Material:
Weight:
PAGE 145
1500 V rms
2200 V rms
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
-30˚C to +100˚C
100,000 Operations
5,000,000 Operations
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL Recognized
(QMFZ2)
8 oz. - 227 Grams approx.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
DC SWITCHING POWER RELAY
199
CLASS 199B
UL Listed
File No. E43641
*
COMPLIES WITH
REQUIREMENTS OF
IEC STANDARDS
947-4-1 AND 947-5-1
LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
* ELECTROTECHNICAL
COMMISSION
DPDT WITH MAGNETIC
BLOWOUT FOR DC ARC
QUENCHING
10 AMP @ 110 VDC
CLASS "B" COIL
INSULATION SYSTEM
OUTLINE DIMENSIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Coil Resistance:
Max. Coil Dissipation:
CONTACTS
Contact Combinations:
Contact Rating :
80% DC Coils, 85% AC coils of
nominal voltage or Less @ 25˚C
10% of Nominal Voltage or More ™ 25˚C
± 10% @ 25˚C
DC Coils-4 Watts Max. Continuous.
2.53 Max.
(64.3)
DPDT
30 Amps up to 300 VAC, 50/60Hz
5 Amps @ 480/600VAC ,0.75pFInductive
Load. 1-1/2 HP Motor Load (each Pole)
@ 120 thru 600 VAC, 50/60 Hz. 2 HP
Motor Load @ 200 thru 600 VAC, 50/60
Hz only when using two poles to switch both
sides of Load 30 Amps @ 28 VDC Resistive
Each Pole.
NEMA A600 Pilot Duty 50/60 Hz
DC Ratings:
10 Amps @ 110 VDC, Resistive; 4 Amps
at 220 VDC, Resistive, 2 Amps @ 325VDC
Resistive. For inductive Loads, contacts
must be derated accordingly. Capacitive
loads must have current limiting to insure
that inrush current will not exceed 50 Amps
Contact Material:
Silver Cadmium Oxide, Gold Flashed.
5/16" Diameter Standard.
TIMING
Operate time:
Release Time:
MAGNETIC
BLOW OUT
SPECIFICATIONS CLASS 199
MAGNETIC
BLOW OUT
Dimensions shown in Inch & (Millimeters)
40 Milliseconds Max. @ Nominal V
30 Milliseconds Max. @ Nominal V
2.50
(63.5)
1.87
(47.5
0.187 Dia.
(2 Places)
LIFE
Electrical (Rated Load)
Mechanical (No Load)
MISCELLANEOUS
Coil Terminals:
Contact Terminals:
Base Material
Weight:
(AC) -30˚C to +50˚C, (DC) -30˚C +60˚C
-30˚C to +100˚C
100,000 Operations
5,000,000 Operations
6-32 Binder Head Screws
8-32 Binder Head Screws
Molded Phenolic, UL Recognized
(QMFZ2)
11 oz. - 312 Grams approx.. (DPDT)
1.62
(41.14)
UP
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
* RELEVANT IEC CONTACT UTILIZATION CATEGORIES
AC-1, AC-3, DC-1, AC-15
SEE SECTION 11, FOR RELEVANT UTILIZATION CATEGORIES
DIELECTRIC STRENGTH
Between Open Contacts: 1500 V rms
Mutually Insulated
2200 V rms
Conductive elements:
TEMPERATURE
Operating Range:
Non-Operating Storage
range:
.375
(9.5)
3.12
(79.24
PART
NUMBERS
COIL Measured @ 25˚C
NOMINAL NOMINAL NOMINAL
RESIS- POWER
INPUT
TANCE
VOLTAGE (OHMS)
CROSS
REFERENCE
POTTER &
BRUMFIELD
AC OPERATED (DPDT WITH BLOW OUT MAGNET)
PRD11AJ0-120
10 VA
W199ABX-14 120 VAC
DC OPERATED (DPDT WITH BLOW OUT MAGNET)
W199BX-14 110 VDC
6000
2.0 W
PRD11DJ0-110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
AUXILIARY CONTACTS AND OTHER COIL VOLTAGES ARE
AVAILABLE ON SPECIAL ORDER. CONTACT FACTORY FOR
SPECIAL REQUIREMENTS.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 146
SERIES
OPEN STYLE - 3 POLE, 30 AMP POWER RELAY
425
The series 425 Power relay is capable of handling up to 30 Amps and
1 Hp Loads. The Series 425 has sufficient spacing to allow for 600
Vac contact ratings . The Design features a enclosed coil, Screw
Terminals and Silver Cadmium Oxide contacts as standard.
The Series 425 has a wide choice of options to choose from.
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
3PDT
3.24
(82.3)
CONTACT LOAD RATINGS 3 POLE RELAYS
Load
30/DC 120-240/AC 208-240/AC 277/AC 600/AC
General Duty
30A
17A
10A
25A
25A
1Ø 1HP◊
Motor (45% PF) 1Ø 1HP◊
3Ø 3HP
◊ PER POLE
0.20 Dia.Typ.
COIL SPECIFICATIONS 3 POLE RELAYS @ 25˚C
Nominal
Voltage
12
24
48
120 *
240 **
480
Resistance
Ohms ± 10%
AC
1.8
6.7
27
170
680
2720
Resistance
Ohms ± 10%
DC
35.5
142
568
2980
-
Current (MA) Power
Consumption
AC
AC
DC
DC
11VA 4.0W
1600
333
11VA 4.0W
820
169
11VA 4.0W
410
84
85
18-21 11VA 4.0W
11VA
43
11VA
22
-
2.50
(63.5)
1.675
(42.5)
1.875
(47.6)
UP
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
* AC Coil is 120V, 50/60Hz, DC Coil is 110-125VD
** For 220 VDC use 3600 Ω, 10 Watt resistor in series with 110 VDC relay.
1, 2, and 3 Pole Relays
Min. Operate:
AC: 85% of nominal Voltage or less @ 25˚C
DC: 75% of nominal Voltage or less @ 25˚C
Max. Over Voltage: 110% of nominal
Struthers-Dunn
ORDERING CODE
Typical Type No.
425 XCX
ULRecognized
File No. E13224
-120A
Series
425 Screw Terminal, 30A, 1-3 Pole
Contact Arrangements
Insulated Armature Types (600V)
CXX 3PST-NO
XCX 3PDT
Options
Tungsten Contacts (High Inrush) - CODE W
0.25 inch quick connect terminals- CODE 18
1 Aux. Contact (SPDT Snap Switch, 10A ) - CODE 90
2 Aux. Contact (SPDT Snap Switches, 10A ) - CODE 91
Coil Voltage
AC: 6, 12, 24, 48, 120, 240, 480 (Add "A")
DC: 6, 12, 24, 48, 110 -125 (Add "D")
PAGE 147
GENERAL SPECIFICATIONS
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
30 mS Max. @ Nominal Voltage.
15 mS Max. @ Nominal Voltage.
INSULATION CHARACTERISTICS
Dielectric Strength
2500 V rms between Mutually insulated
current carrying parts and those parts to
ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
ENVIRONMENTAL CAPABILITIES
Ambient Temperature Rating: AC: -55˚C to +45˚C @ Rated Operation.
DC: -55˚C to +80 ˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Weight:
10 Million Operations no load
100,000 Operations @ Rated Load.
Open Style
Small Base 9oz. large base 11 oz.approx.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
OPEN STYLE 30 AMP POWER RELAY
CLASS
88UKD
CLASS 88UKD RELAY
SIDE COIL SOLDER TERMINALS
UL Recognized
File No. E43641
SPST-N.O. DM, RATED 30 AMPS
1/4"QUICK CONNECT /SOLDER TERMINALS
SWITCHES UP TO 1 HP AT 600 VAC
1.25Max.
(31.7)
1.937.
(49.1)
1.406
(35.7)
.250
(6.35)
.078
(1.98)
.062
(1.57)
.437
(11.1)
.156
(3.9)
6-32 tapped mt.
hole x .312
deep
SPECIFICATIONS 88UKD
COIL
Pull-in Voltage (AC):
Pull-in Voltage (DC):
Dropout Voltage:
Max. allowed voltage
Coil Resistance:
85% of Nominal Voltage or less
80% of Nominal Voltage or less
10% of nominal voltage or more
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Contact Resistance:
1/4' silver alloy, gold flashed.
Initial 50 Milliohms @ rated current.
TEMPERATURE
Operating:
VIBRATION RESISTANCE
Functional:
5g's 10 to 55Hz.
30 Amps up to 300VAC/28VDC,
Resistive Load
5 Amps @ 600VAC Resistive.Load
1 HP @ 120-600 VAC Motor load.
Contact Rating:
TIMING
Operate Time:
Release Time:
25 mS Max. @ Nominal Voltage.
20 mS Max. @ Nominal Voltage
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Contacts to frame:
Insulation Resistance:
3000 V rms
1000 V rms
3000 V rms
1000 megohms min. @ 500 VDC
SHOCK RESISTANCE
Functional:
5g's 11mS Max.
LIFE EXPECTANCY
Mechanical:
Electrical:
5 Million Operations
100,000 Operations @ Rated Load.
MISCELLANEOUS
Contact Insulation:
Style:
Mounting:
Weight:
Coil Measured @ 25˚C
PART
NUMBERS
NOMINAL
INPUT
VOLTAGE
AC OPERATED COIL
24VAC
120VAC
240VAC,60Hz
220VAC,50Hz
DC OPERATED COIL
12 VDC
W88UKDX-2
24 VDC
W88UKDX-3
110 VDC
W88UKDX-4
W88UKADX-3
W88UKADX-4
W88UKADX-5
-10˚C to +50˚C @ Rated Operation. (AC )
-10˚C to +60˚C @ Rated Operation. (DC )
NOMINAL
NOMINAL
RESISTANCE POWER
(OHMS)
-
3VA
3VA
-
3VA
100
400
8000
1.5W
1.5W
1.5W
Movable & stationary contacts are mounted
on a molded plastic barrier insulator.
Open style construction.
6-32 tapped hole and locating tab.
85 Grams, 3 oz. approx.
CROSS REFERENCE
TO
POTTER & BRUMFIELD
KR-3AH-24
KR-3AH-120
KR-3AH-240
KR-3DH-12
KR-3DH-24
KR-3DH-110
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 148
SERIES
SCREW TERMINAL 15 AMP, 1 AND 2 POLE POWER RELAY
415
R
Listed (XBX Only)
file No. E13224
The Series 415 is a compact, 15 amp base mounted industrial relay. It is a versatile
relay that offers a variety of contact configurations and options. Excellent contact life
assures long mechanical life and contact reliability on low level loads. Screw
terminals are standard. Options include: high voltage or high inrush contacts, quick
connect terminals, permanent magnet blowout and low power DC coils.
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeters)
1.87
(47.4)
1.50
(38.1)
2.75
(69.85)
2.35
(59.69)
4 mtg.holes
0.181 ± .005 Dia.
MAXIMUM DEPTH DIMENSION OF CONTACTOR 1.75",
(44.45)
UP
VERTICAL MOUNTING
RECOMMENDED WITH
CONTACTS UP
WIRING DIAGRAMS
TOP VIEW
Struthers-Dunn
ORDERING CODE
Typical Type No.
415
XBX
18
415XAX
415BXX
415XBX
415HXX
-120A
Series
415 Screw Terminals, 15 Amp
1 and 2 pole
Contact Arrangements
BXX (DPST-NO.
HXX (SPST-NO-DM
XAX (SPDT)
XBX (DPDT)
XHX (SPDT-DB-DM
XXH (SPST-NC-DB
Options
0.25 inch quick connect terminals - CODE 18
Permanent Magnet Blowout - CODE 69
(Consult Factory for other options)
Coil Voltage
AC: 6, 12, 24, 48, 120, 240, (Add "A")
DC: 6, 12, 24, 32, 48, 115-125 (Add "D")
415XXH
415XHX
Special coils: Low Power (mW), series coils.
High Inrush contacts: 10 Amps continuous, 150 Amp Inrush.
High Voltage Contacts: Up to 4KV
PAGE 149
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SCREW TERMINAL 15 AMP, 1 AND 2 POLE POWER RELAY
RESISTIVE MOTOR
(80% pF)
415
CROSS REFERENCE
STRUTHERS-DUNN TO WARD LEONARD
CONTACT RATINGS
LOAD
SERIES
30/VDC
120VAC
240VAC
15A
-
15A
1/2HP
10A
1HP
AC COIL SPECIFICATIONS @ 25˚C (6VA)
mA @ nominal voltage
Nominal Voltage Resistance
Inrush
Sealed
(60HZ)
Ohms ± 10% Current
Coil
6
1000
1.5
1800
12
500
6.3
900
250
24
25
450
48
125
100
225
120
50
620
90
240
25
2500
45
DC COIL SPECIFICATIONS @ 25˚C (3.5W)
Nominal Voltage Resistance mA @ nominal voltage
Coils
Coils
(VDC)
Ohms ± 10% Cold
Hot
6
500
10
600
12
250
40
300
24
125
155
150
32
95
390
112
48
62
620
75
*115/125
26
4000
31
* 220-250 VDC relays supplied with resistor in series
with 115/125 VDC coil.
STRUTHERS-DUNN WARD LEONARD
DC COIL 2 POLE N.O.
415BXX-6D
105-1420
415BXX-12D
105-3420
415BXX-24D
105-4420
415BXX-110D
105-6420
DC COIL 2 POLE N.C..
415XXB-6D
105-1421
415XXB-12D
105-3421
415XXB-24D
105-4421
415XXB-110D
105-6421
DC COIL DPDT
415XBX-6D
105-1422
415XBX-12D
105-3422
415XBX-24D
105-4422
415XBX-110D
105-6422
AC COIL 2 POLE N.O..
415BXX-6A
105-1520
415BXX-12A
105-3520
415BXX-24A
105-4520
415BXX-120A
105-6520
AC COIL 2 POLE N.C..
415XXB-6A
105-1521
415XXB-12A
105-3521
415XXB-24A
105-4521
415XXB-120A
105-6521
415XXB-240A
105-7521
AC COIL DPDT
415XBX-6A
105-1522
415XBX-12A
105-3522
415XBX-24A
105-4522
415XBX-120A
105-6522
415XBX-240A
105-7522
NOTE:
THE 105 STYLE IS SLIGHTLY SMALLER WITH
A DIFFERENT MOUNTING HOLE PATTERN.
GENERAL SPECIFICATIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
80% of nominal voltage or less measured
at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
25 mS Max. @ Nominal Voltage.
10mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points: 1500 V rms between all mutually
Insulated current carrying parts and
those parts to ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
TEMPERATURE
Temperature Rating:
LIFE
EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Weight:
AC: -45˚C to +55˚C @ rated operation.
DC: -45˚C to +70˚C @ rated operation
20 Million Operations no load
200,000 Operations @ Rated Load.
500,000 Operations @ 1/2 rated load.
4 oz. (113 g) approx.
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 150
SERIES
MOTOR REVERSING CONTACTOR, 1 & 3 HP, 6 POLE
A275
The Series A275 relay is a 2 coil, compact motor reversing contactor which finds
extensive applications in the Industrial door operator Industry, the hoist Industry and
electronic wheel balancers, to name a few. The A275 has Q.C. coil terminals
extending out the back (opposite the contact terminals), mechanically interlocked
armatures is a standard feature.
UL Recognized
File No. E13224B
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeters)
2.985
(75.81 2.56
(65.0)
2.31
(58.9)
1.59
(40.3)
3.37
(85.6)
UP
3.62
(91.9)
.187 (4.76)
2 holes for
#8 screws
A
U
X
RECOMMENDED
MOUNTING POSITION
2.75
(69.8)
WIRING DIAGRAM
TOP VIEW
Main contact terminals are
numbered on contactor
Struthers-Dunn
ORDERING CODE
Typical Type No.
A275
KXX
Series
A275, 1/4" Terminals, motor reversing.
Continuous , 1 & 2 Hp, 3 pole models
Contact Arrangements
KXX (3PDM-NO., per coil)
Options
2 Aux. contacts, each SPDT
(1 per coil) 1/4" Q.C. terminals - CODE 90
4 Aux. contacts, each SPDT
(2 per coil) 1/4" Q.C. terminals - CODE 91
Rectified Coil - CODE V2
Coil Voltage
AC: 12, 24, 110, 120, 220, 240 (Add "A")
DC: 12, 24, 32, 48, 120 (Add "D")
90
-24A
1
2
3
4
5
6
7
8
9
Auxiliary contact
Snap Switches
OPTIONS (CONSULT FACTORY)
PAGE 151
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
MOTOR REVERSING CONTACTOR, 1 & 3 HP, 6 POLE
SERIES
A275
GENERAL SPECIFICATIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
AC: 85%, DC: 80% of nominal voltage
measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
50 mS Max. @ Nominal Voltage.
30 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points: 2500 V rms between all mutually
Insulated current carrying parts and
those parts to ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
TEMPERATURE
Temperature Rating:
LIFE
EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Weight:
AC: -45˚C to +50˚C @ rated operation.
DC: -45˚C to +70 ˚C @ rated operation.
5 Million Operations no load
100,000 Operations @ Rated Load.
500,000 Operations @ 1/2 rated load.
1 pound, approx..
CONTACT RATINGS
DC COIL SPECIFICATIONS @ 25˚C
AC CONTACTS: Rated with all contacts in use, not rated per pole.
VOLTAGE
(60HZ)
120
240
240
480/600
PHASE
1-2-3
1
2-3
2-3
MOTOR
RESISTIVE
LOADS (HP) LOAD (AMPS)
15
1
10
1.5
10
3
5
3
DC CONTACTS
VOLTAGE
(DC)
30
125
RESISTIVE
LOAD (AMPS)
15
5
600 volt spacing to ground.
300 volt spacing for auxiliary contacts.
Nominal
Voltage
12
24
32
48
120
Resistance Power
Ohms ± 10% Consumption
31.0
4.5W
125
4.6W
210
4.9W
500
4.6W
3240
4.4W
Polypropylene encapsulated coils
AC COIL SPECIFICATIONS @ 25˚C
Resistance Power
Nominal
Ohms ± 10% Consumption
Voltage
17VA
1.24
12V/50-60hz
16.7VA
4.63
24V/50-60hz
16.8VA
125
110V/50-120V/60hz
16.8VA
500
220V/50-240V/60hz
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 152
SERIES
A575
2 COIL MOTOR REVERSING CONTACTOR 1.5 - 7.5HP, 6 POLE
The Series A575 relay is rated to 7.5 HP. Two sets of 3 pole, double-make, N.O.
contacts are mechanically Interlocked to prevent simultaneous closure. Front
mounted auxiliary contacts are available for electrical lockup and lockout. All
versions have silver cadmium oxide contacts. The A575 motor reversing contactor
is widely used for control of overhead doors, elevators, hoists, machine tools, and
other similar devices that requires frequent jogging.
UL Recognized
File No. E13224
OUTLINE DIMENSIONS
Dimensions shown in Inch and (Millimeters)
NO
NC
NO
COM
NC
COM
2.56
(65.0)
3.40
(86.3)
4.43
(112.5)
MTG. HOLES
.196 DIA. (4.97)
2 PLACES
4.75
(120.6)
5.25
(132)
UP
MAXIMUM DEPTH DIMENSION OF CONTACTOR 3.00", (76.2)
RECOMMENDED
MOUNTING POSITION
WIRING DIAGRAM
Struthers-Dunn
ORDERING CODE
Typical Type No.
A575
KXX
Series
A575, Screw Terminals, 2 coil motor
rev. contactor, 1.5 - 7.5 HP
Contact Arrangements
KXX (3PDM-NO., per coil)
Options
1 Form SPST-NO & SPST-NC Aux. contacts
per coil, Rated 5 Amps - CODE 74
SPDT Aux. contact per coil
Rated 5 Amps. - CODE 90
Coil Voltage
AC: 12, 24, 120, 240, 440, 550 (Add "A")
DC: 12, 24, 115-125, 240 (Add "D")
90
-24A
1
3
4
6
7
9
AUXILIARY
CONTACTS
Mechanical Interlock omitted, Consult Factory
OPTIONS (CONSULT FACTORY)
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 153
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
2 COIL MOTOR REVERSING CONTACTOR 1.5 - 7.5HP, 6 POLE
SERIES
A575
GENERAL SPECIFICATIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
AC: 85%, DC: 80% of nominal voltage
measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
60 mS Max. @ Nominal Voltage.
30 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points: 2500 V rms between all mutually
Insulated current carrying parts and
those parts to ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
TEMPERATURE
Temperature Rating:
LIFE
EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Weight:
-40˚C to +50˚C @ rated operation.
5 Million Operations no load
100,000 Operations @ Rated Load.
250,000 Operations @ 1/2 rated load.
1.5 pounds, approx..
CONTACT RATINGS
AC COIL SPECIFICATIONS @ 25˚C (22VA)
Nominal
Voltage
12
24
*120
240
440
550
Resistance
Ohms ± 10%
1.00
5.30
92.0
420
2100
3100
Nominal
Current
1.833 AMP
0.917 AMP
0.183 AMP
0.920 AMP
0.050 AMP
0.040 AMP
VOLTAGE
LOAD
(60HZ)
120
3PST-DM-NO 208/240
208/240
(per pole)
480/600
* AC coil is 120, 50-60HZ
PHASE
1
1
2-3
2-3
MOTOR
RESISTIVE
LOADS (HP) LOAD (AMPS)
30
1-1/2
30
3
30
5
15
7-1/2
DC CONTACTS
LOAD
3PST-DM-NO
(per pole)
VOLTAGE
(DC)
115
230
RESISTIVE
LOAD (AMPS)
15
2
DC COIL SPECIFICATIONS @ 25˚C (10 WATT)
Nominal
Voltage
12
24
**120
240
Resistance
Ohms ± 10%
16.5
58.2
1,450
4,200
Nominal
Current
0.727
0.412
0.083
0.055
AUXILIARY CONTACTS
LOAD
1 FORM "A"
"B" OR "C"
VOLTAGE
(AC)
120
240
RESISTIVE
LOAD (AMPS)
5
5
** DC coil is 110-125 VDC
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 154
SERIES
101-102-103 50,100 & 200 AMP SINGLE POLE DC CONTACTORS
The Series 101, 102 and 103 are DC solenoid-actuated, heavy duty contactors.
Each contactor has a single pole, double-make normally open contact. Contacts
are enclosed with a molded plastic cover. The series 101 is rated at 50 amps
continuous duty. The series 102 is rated 100 amps continuous and the series 103 is
rated at 200 amps continuous. Coils are rated for DC only, as standard. The powerful
magnetic structure creates very high contact pressure which results in very reliable
and low resistance contacts, making them suitable for power applications in telecommunications, elevator and rail mass transit as well as other Industries.
OUTLINE DIMENSIONS
A
B
E
F
UP
C
RECOMMENDED
MOUNTING POSITION
D
(DEPTH FRONT TO BACK)
UP
Dimensions shown in Inch and (Millimeters)
Dim.
A
B
C
D
E
F
RECOMMENDED
MOUNTING POSITION
101HXX
2.69 (68.33)
1.87 (47.4)
2.50 (63.5)
1.84 (46.7)
0.40 (10.1)
0.43 (10.9)
102HXX
3.38 (85.73)
2.25 (57.1)
3.22 (81.79)
2.09 (53.0)
0.56 (14.2)
0.50 (12.7)
103HXX
4.25 (107.9)
2.40 (60.9)
3.53 (89.66)
2.65 (67.31)
0.92 (23.3)
0.56 (14.2)
Mounting holes (2) - .265 (6.73) Inch Dia.
Struthers-Dunn
ORDERING CODE
Typical Type No.
102
HXX
-28D
Series
101 Screw Term., 50 Amp, 1 pole
102 Screw Term., 100 Amp, 1 pole
103 Screw Term., 200 Amp, 1 pole
Contact Arrangements
HXX- 1 Pole D.M.- N.O. Standard.
HXH- 2 Pole D.B. -1 N.C. and 1 N.O.103 only.
JXX- 2 Pole D.M. N.O
XRX- SPDT-M-B (Make before break, 103 only)
XXH- 1Pole-D.B. + 1NC (103 only)
WIRING DIAGRAM
101HXX
102HXX
103HXX
Coil Voltage
DC: 12, 28, 48, (Add "D")
Note: Contact arrangements other than the standard HXX will
require a 3 digit suffix number to be added to the type number.
This is done by the factory and will be shown after the contact
arrangement code. Contact factory for suffix number.
OPTIONS (CONSULT FACTORY)
AC COIL INPUT VOLTAGES
NON STANDARD DC COIL VOLTAGES
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 155
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
50,100 & 200 AMP SINGLE POLE DC CONTACTORS 101-102-103
GENERAL SPECIFICATIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
DC: 80% of nominal voltage measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
60 mS Max. @ Nominal Voltage.
30 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points: 1500 V rms between all mutually
Insulated current carrying parts and those
parts to ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
TEMPERATURE
Temperature Rating:
-45˚C to +65˚C @ rated operation.
LIFE
EXPECTANCY
Mechanical:
Electrical:
500,000 Operations no load
100,000 Operations @ Rated Load.
TERMINALS
Coil
101 - #6-32
102 - #8-32
103 - #8-32
MOUNTING
Weight
Clearance Holes, ea. .265 in dia.
13 oz., 370 Grams
Load Term.
#10-32
#1/4-20
#3/8-18
AC CONTACT RATINGS
RESISTIVE LOAD (AMPS)
VOLTAGE
AC (60HZ) Series 101 Series 102 Series 103
50
120
200
100
50
240
200
100
DC CONTACT RATING
VOLTAGE
(DC)
30
RESISTIVE LOAD (AMPS)
50
100
200
DC COIL SPECIFICATIONS @ 25˚C
Nominal
Voltage
(VDC)
12
28
48
101HXX
(9W Max)
102HXX
103HXX
(10.5W Max) (13.3W Max)
Resistance Resistance Resistance
Ohms ± 10% Ohms ± 10% Ohms ± 10%
17
10.8
26
75
59
98
290
173
267
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 156
SERIES
20 AMP GROUND FAULT INTERRUPT (GFI) RELAY
214
The Series 214 Ground fault interrupt relay (GFI) to our knowledge, the smallest
relay ever, to pass Underwriters Laboratories 20 Amp overload test for ground fault
interrupting devices. Both resistive and Inductive loads of 120 Amps at 120 volts
must be switched ten times each without failure. The 214 GFI is most commonly
found in portable (plug) GFI equipment. This relay is also appropriate for other
applications where size, weight, and the ability to safely handle occasional severe
overloads is of primary importance.
OUTLINE DIMENSIONS
Dimensions shown in inch and (Millimeters)
UL Recognized
File No. E13224
# 17 AWG Stranded tinned copper wire insulated
with .032 thick wall gray silicone rubber
1.37
(34.7)
.839
(21.3)
WIRING DIAGRAM
+.000
+.000
.900 - .010 0.30 Max.
(7.62)
(22.8)
.900 - .010
(22.8)
CL
1.00
(25.4)
.500
(12.7)
0.70 x .150 slot
(2 places)
Mounting hole # 6-32 thd.
.375 deep min. with .250
full form threads
VOLTAGE
AC (50/60HZ)
120
240
COIL SPECIFICATIONS @ 25˚C
Nominal
Nominal
Resistance
Voltage
Ohms ± 10% Power
(mA)
(VDC)
360
6
5
175
20
12
90
24
80
17
115
2000
VOLTAGE
(DC)
30
Nominal
Resistance
Ohms ± 10% Power
(mA)
30
120
480
10,000
200
100
50
11.5
RESISTIVE LOAD (AMPS)
20
* Normally open contact switched 10 times
GENERAL SPECIFICATIONS
DC: 80% of nominal voltage measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
Struthers-Dunn
TIMING
Operate Time:
Release Time:
15 mS Max. @ Nominal Voltage.
15 mS Max. @ Nominal Voltage.
214
DIELECTRIC STRENGTH
All Mutually Insulated Points: 2000 V rms between all mutually
Insulated current carrying parts and those
parts to ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
HXX
-24D
Series
Open Style, Tapped pole piece with
antirotation tab. solder terminals on
.Coil, # 17 AWG wire contacts.
Contact Arrangements
HXX (1 Pole double make N.O.) Standard
BXX DPST-NO (2 Form A)
Coil Voltages
AC: 6, 12, 24, 120 ( Add A)
DC: 6, 12, 24, 110-125 (Add "D")
TEMPERATURE
Temperature Rating:
EXPECTANCY
Mechanical:
Overload:
Electrical:
-45˚C to +65˚C @ rated operation.
LIFE
TERMINALS
OPTIONS
The 214 GFI is normally custom built to meet each
Customers unique requirements. Consult Factory.
MISCELLANEOUS
Mounting position:
Weight:
10,000,000 Operations no load
120 VAC @ 120 Amps, 10 cycles
100,000 Operations @ Rated Load.
Coil
Load Terminals
Pierced Solder lug # 17 AWG. Silicone
Rubber.
Tapped pole piece & anti rotation Tab.
Any
2.5 oz. 71 Grams
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 157
-
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
NOTE: Other DC voltages available with or without rectifiers
installed. AC versions without rectifiers can be supplied but
not recommended. Consult Factory
ORDERING CODE
Typical Type No.
RESISTIVE LOAD (AMPS)
CONTINUOUS
MAX. OVERLOAD
20
120 *
20
DC CONTACT RATING
DC COIL
AC COIL 50/60hZ
0.62 x .093 slot
(2 places)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
GENERAL SPECIFICATIONS
CLASS
MDR
MDR'S ARE IDEAL FOR SWITCHING RESISTIVE, TUNGSTEN, AND
MOTOR LOADS FOR BOTH AC AND DC APPLICATIONS.
PROTECTIVE CO
IL
COVERS
UL Listed
File No. E52197
HERMETICALLY SEALED IN STEEL TUBES
Every contactor tube is hermetically sealed to provide
maximum life, protection to the user from arcing and the
hazards of switching heavy loads with exposed contacts.
LIQUID MERCURY CONTACT
Liquid mercury means a new contact surface after
every operation. Mercury is self-renewing, it cannot
pit, weld, disintegrate or oxidize. The internal
resistance of the contact surfaces typically measure
only a few Milliohms and is ideal for switching large
loads safely.
SPECIFICATIONS MERCURY DISPLACEMENT RELAYS
COIL
Frequency of Operation:
Pull-in voltage
Dropout voltage
CONTACTS
Material:
Contact resistance:
TIMING
Operate (at nominal voltage)
Dropout (at nominal voltage)
60 per minute maximum
80% of nominal voltage, Typ. AC & DC coils.
78% of nominal voltage, typ. AC coils
65% of nominal voltage, typ. DC coils
Mercury
.002 ohm M60 & M100
.003 ohm M30 & M35
50 Milliseconds typical
80 Milliseconds typical
DIELECTRIC STRENGTH
All mutually insulated points to ground: 2650 V rms
TEMPERATURE
Operating:
- 35˚C to + 60˚C Under continuous load.
LIFE
Mechanical: (No load)
Electrical (Rated load)
5,000,000 Operations
250,000 Operations
MISCELLANEOUS
Insulation Material:
Mounting:
Options:
Class B - 130˚C & M35 pressure connectors for
AWG 6-14 wire; M60 pressure connectors for AWG
2 - 12 wire
Vertical ±10˚
Combination of SPST-NO & SPST-NC contact configurations.
available. Other coil voltages available .
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 158
CLASS
MDR
APPLICATION DATA
MERCURY DISPLACEMENT TUBE
GLASS INSULATOR
WELD
PLUNGER GUIDE
CERAMIC LINER
ELECTRODE
ARC QUENCHING ATMOSPHERE
MAGNETIC LINER
PLUNGER GUIDE
BUFFER SPRING
MERCURY POOL
STAINLESS STEEL CAN
PRINCIPLE OF OPERATION
The sectional view shows our normally open style Mercury Displacement tube with the plunger assembly
floating on the mercury pool.
When the coil power is off, the mercury level is below the electrode tip. No electrical path exists between
the electrode and mercury pool.
When coil power is applied, the plunger is drawn down into the mercury by the pull of the magnetic field.
This action raises the mercury level, so it covers the end of the electrode closing the circuit.
When coil power is turned off, the buoyant force of the mercury causes the plunger assemble to rise,
dropping the mercury level, and breaking the circuit.
APPLICATION DATA
Mercury Displacement relays are ideal for adverse environments....Where high inrushes are encountered
....Where hermetically sealed contact operation is required because of corrosive, dirty, or moist ambient
conditions.
....Where use does not permit contact maintenance.
....Where reduced noise levels are required.
....where minimum weight and size are desired.
DESIGN FEATURES
Liquid Mercury Contact - provides a new contact surface with every actuation. Mercury is self-renewing
and does not pit, weld, disintegrate or oxidize.
Hermetic sealing - provides internal and external protection from arcing.
Inert Gas atmosphere - contactor tube is evacuated, then pressurized with a combination of gases which
extinguish arcing and contribute to long life. The pressurized gases provide for a high dielectric withstanding voltage between contact surfaces.
Low Contact Resistance - Large electrode and mercury volume creates low contact resistance and
provides high inrush current capability.
Quiet Operation - Switch clacking normally associated with conventional hard contactors, is eliminated
with mercury displacement tubes and the buffer spring assembly.
APPLICATION OF "M" SERIES VS "ML" SERIES
The series "ML" is physically the same as the "M" series except for the type of gases used in the
contactor tubes. The "ML" series was developed for use with resistive and tungsten loads on AC power
ONLY. The "ML" series will give much greater life than the "M" series for these types of loads and is
intended for high activation use, such as molding machines or ovens.
The "ML" series, however is not intended for use with motor loads on AC power, or for resistive, tungsten,
or motor loads on DC power. The "M" series, which is our universal series is rated
to be used on all types of loads resistive, tungsten, and motor for both AC and DC power
PAGE 159
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
30 AMP MERCURY DISPLACEMENT RELAY
CLASS
MDR
CLASS M30
RATED 30 AMPS
SWITCHES RESISTIVE
TUNGSTEN, AND MOTOR LOADS
1 POLE N.O. CONTACT
CONTACTOR
TERMINALS
.180 Dia.
(4.6)
2 Holes
COIL
TERMINALS
4.18
(106.4)
2.03
(51.6)
1.187
(30.2)
2.0
(50.8)
UL Listed
File No. E52197
1.62
(41.3)
2.12
(58.7)
.531
(13.5)
UP
RECOMMENDED MOUNTING POSITION ± 10˚
FOR EXTENDED LOAD LIFE WHEN SWITCHING RESISTIVE AND
TUNGSTEN LOADS ORDER THE ML30-STYLE. OTHER COIL
VOLTAGE AND CONTACT COMBINATIONS AVAILABLE.
CONSULT FACTORY.
Construction in accordance with VDE 0660 and 0110 (Insulation
group 380)
Weigh:
13 ozs. 370 grams
VOLTAGE
120VAC
240VAC
480VAC
600VAC
24VDC
48VDC
125VDC
250VDC
CONTACTOR RATINGS FOR M30A - M30B
RESISTIVE
MOTOR
HP
PHASE
AMPS
AMPS
1Ø
3Ø
1Ø 3Ø
24
1Ø 3Ø
2*
19.2
3*
30*
28
5*
19
7.5*
30*
1Ø 3Ø
1Ø 3Ø
14
5* 10*
14
30*
11.2 11
5* 10*
1Ø 3Ø
25 **
DC
1/2
30*
27
DC
1/2
30*
13.5
DC
1/2
16*
5.2
DC
1/2
12*
2.6
* UL and CSA Listed
TUNGSTEN
AMPS
30*
15
7.5
6
30*
30*
16*
12*
** CSA only
PART NUMBER
NOMINAL
INPUT
VOLTAGE
WM30A-120A
120 VAC
COIL Measured @ 25˚C
NOMINAL
NOMINAL
RESISTANCE CURRENT
(OHMS)
700
.058
NOMINAL
POWER
7VA
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 160
CLASS
M35 AND M60 DIMENSIONS
MDR
DIMENSION
1 POLE
A
B
C
2 POLE
D
E
3 POLE
F
G
H
J
M60A-ML60A M60B-ML60B M35A-ML35A M35B-ML35B
2.375 Max.
(60.3)
5.06 Max.
(128.52)
1.06 Max.
(27)
3.250 Max.
(82.6)
5.062 Max.
(128.52)
1.812 Max.
(46.0)
3.250 Max.
(82.6)
5.062 Max.
(128.52)
1.812 Max.
(46)
1.50Max. *
(38.1)
5.062 Max.
(128.52)
1.937 Max.
(49.2)
2.281Max.
(57.9)
5.062 Max.
(128.52)
2.781 Max.
(70.6)
2.281 Max.
(57.9)
5.062 Max.
(128.52)
2.781 Max.
(70.6)
2.312 Max.
(58.7)
4.875 Max.
(123.8)
0.937 Max.
(23.8)
3.187 Max.
(81.0)
4.875 Max.
(123.8)
1.687 Max.
(42.9)
3.187 Max.
(81.0)
4.875 Max.
(123.8)
1.687Max.
(42.9)
1.375 Max.
(34.9)
4.875 Max.
(123.8)
1.875 Max.
(47.6)
2.218 Max.
(56.3)
4.875 Max.
(123.8)
2.656 Max.
(57.4)
2.218 Max.
(56.3)
4.875 Max.
(123.8)
2.656 Max.
(67.4)
* SPST-NC outline is not
shown. The SPST-NC
tube is positioned lower
on the coil so Dimension
A is lower, but the overall
height remains the same.
DIMENSIONS SHOWN IN INCHES AND (MILLIMETERS)
3.12
(79.4)
2.28
(58)
CONTACTOR
TERMINALS
CONTACTOR
TERMINAL
.180 Dia.
(4.6)
2 Holes
.205 Dia.
(5.2)
4 Holes
D
A
B
2 POLE
35AMP OR 60 AMP
1 POLE
35AMP OR
60 AMP
1.77
(45)
COIL
TERMINALS
COIL
TERMINALS
1.93
(49.2)
E
1.62
(41.3)
F
C
3.50
(88.9)
2.06
(52.4)
1.187
(30.2)
2.0
(50.8)
2.312
(58.7)
2.312
(58.7)
3.75
(95.3)
3.12
2.75 (79.4)
(69.9)
CONTACTOR
TERMINAL
30˚
30˚
.205 Dia.
(5.2)
6 Holes
G
COIL
TERMINALS
1.93
(49.2)
3 POLE
35AMP OR 60 AMP
H
1.77
(45)
J
2.28
(58)
PAGE 161
3.36
(85.5)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
35 AND 60 AMP MERCURY DISPLACEMENT RELAYS
MDR
CLASS WM35 and WM60
SWITCHES RESISTIVE,
TUNGSTEN, AND MOTOR LOADS
STAINLESS STEEL TUBE S
HIGH INRUSH CAPACITY
UL Listed
File No. E52197
1 POLE
Weight
13 Ozs.,
(370 Grams)
CONTACTOR RATINGS FOR M35A - M35B
VOLTAGE
PHASE
120VAC
240VAC
480VAC
600VAC
24VDC
48VDC
125VDC
250VDC
1Ø 3Ø
1Ø 3Ø
1Ø 3Ø
1Ø 3Ø
DC
DC
DC
DC
* UL and CSA Listed
HP
1Ø 3Ø
3*
5*
5*
7.5*
5* 10*
5* 10*
1/2
1/2
1/2
1/2
RESISTIVE
AMPS
MOTOR
AMPS
1Ø
3Ø
34
30
28
19
14
14
11.2 11
27
13.5
5.2
2.6
35*
35*
35*
25 **
35*
35*
16*
12*
TUNGSTEN
AMPS
35*
17
9
7
35*
35*
16*
12*
** CSA only
2 POLE
Weight
26 Ozs.,
(738 Grams)
CONTACTOR RATINGS FOR M60A - M60B
VOLTAGE
PHASE
120VAC
240VAC
480VAC
600VAC
24VDC
48VDC
125VDC
250VDC
1Ø 3Ø
1Ø 3Ø
1Ø 3Ø
1Ø 3Ø
DC
DC
DC
DC
HP
1Ø 3Ø
3*
5*
5*
10*
7.5* 15*
7.5* 15*
3/4
3/4
3/4
3/4
MOTOR
AMPS
1Ø
3Ø
34
30
28
28
21
21
16
17
39
19.5
7.4
3.7
RESISTIVE
AMPS
60*
60*
60*
50 **
60*
60*
40*
20*
* UL and CSA Listed
** CSA only
SEE MDR GENERAL SPECIFICATIONS AND DIMENSIONS.
TUNGSTEN
AMPS
AMPS
"B" (N.C.)
"A" (N.O.)
45*
60*
22.5
30
11.2
15
9
12
50*
50*
50*
50*
40*
40*
20*
20*
UP
3 POLE
Weight
2Lbs. 6 ozs.,
(1078 Grams)
RECOMMENDED MOUNTING
POSITION ± 10˚
COIL Measured @ 25˚C
NOMINAL
NOMINAL
NOMINAL NOMINAL
PART
RESISINPUT
CURRENT POWER
NUMBERS
TANCE
VOLTAGE
(AMPS)
(OHMS)
1 POLE NORMALLY OPEN CONTACT
WM35A-120A
700
7VA
.058
120 VAC
WM35A-240A
2,800
7VA
.029
240VAC, 60HZ
220VAC, 50HZ
WM35A-24D
186
3.5W
.120
24VDC
2 POLE NORMALLY OPEN CONTACTS
WM35AA-120A
218
16.5VA
.135
120 VAC
WM35AA-240A
1,200
16.5VA
.063
240VAC, 60HZ
220VAC, 50HZ
WM35AA-24D
98
6W
.232
24VDC
3 POLE NORMALLY OPEN CONTACTS
WM35AAA-120A 120 VAC
111
28VA
.220
WM35AAA-240A 240VAC, 60HZ
430
28VA
.117
220VAC, 50HZ
WM35AAA-24D 24VDC
64
9W
.375
1 POLE NORMALLY CLOSED CONTACT
WM35B-120A
460
13VA
.115
120VAC
COIL Measured @ 25˚C
NOMINAL
NOMINAL
NOMINAL NOMINAL
PART
RESISINPUT
CURRENT POWER
NUMBERS
TANCE
VOLTAGE
(AMPS)
(OHMS)
1 POLE NORMALLY OPEN CONTACT
WM60A-120A
700
7VA
120 VAC
..058
WM60A-240A
2,800
7VA
240VAC, 60HZ
.029
220VAC, 50HZ
WM60A-24D
186
3.5W
24VDC
.120
2 POLE NORMALLY OPEN CONTACTS
WM60AA-120A 120 VAC
218
16.5VA
.135
WM60AA-240A 240VAC, 60HZ
1,200
16.5VA
.063
220VAC, 50HZ
WM60AA-24D
98
6W
24VDC
.232
3 POLE NORMALLY OPEN CONTACTS
WM60AAA-120A 120 VAC
111
28VA
.220
WM60AAA-240A 240VAC, 60HZ
430
28VA
.117
220VAC, 50HZ
WM60AAA-24D 24VDC
64
9W
.375
1 POLE NORMALLY CLOSED CONTACT
WM60B-120A
460
13VA
120VAC
.115
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 162
CLASS
35 AND 60 AMP MERCURY DISPLACEMENT RELAYS
MDR
CLASS WML35 and WML60
UL Listed
File No. E52197
RECOMMENDED FOR MUCH LONGER LIFE
WHEN SWITCHING RESISTIVE AND TUNGSTEN LOADS.
AVAILABLE FOR AC LOADS ONLY.
NOT RECOMMENDED FOR SWITCHING DC LOADS.
UP
2 POLE
Weight
26 Ozs., (738 Grams)
1 POLE
Weight
13 Ozs., (370 Grams)
3 POLE
Weight
2Lbs. 6 ozs., (1078Grams)
RECOMMENDED MOUNTING
POSITION ± 10˚
CONTACTOR RATINGS FOR ML35A - ML35B
CONTACTOR RATINGS FOR ML60A - ML60B
VOLTAGE
RESISTIVE
AMPS
TUNGSTEN
AMPS
VOLTAGE
RESISTIVE
AMPS
120VAC
240 VAC
480VAC
600VAC
35*
35*
35*
25 **
35*
17
9
7
120VAC
240VAC
480VAC
600VAC
60*
60*
60*
50 **
* UL and CSA Listed
** CSA only
* UL and CSA Listed
TUNGSTEN
AMPS
AMPS
"B" (N.C.)
"A" (N.O.)
45*
60*
22.5
30
11.2
15
9
12
** CSA only
COIL Measured @ 25˚C
NOMINAL
NOMINAL NOMINAL
RESISCURRENT POWER
TANCE
(AMPS)
(OHMS)
1 POLE NORMALLY OPEN CONTACT
WML35A-120A
700
7VA
..058
120 VAC
WML35A-240A
2,800
7VA
.029
240VAC, 60HZ
220VAC, 50HZ
2 POLE NORMALLY OPEN CONTACTS
COIL Measured @ 25˚C
NOMINAL
PART
NOMINAL NOMINAL
RESISNUMBERS
CURRENT POWER
TANCE
(AMPS)
(OHMS)
1 POLE NORMALLY OPEN CONTACT
120 VAC
700
7VA
WML60A-120A
..058
240VAC, 60HZ
2,800
7VA
WML60A-240A
.029
220VAC, 50HZ
2 POLE NORMALLY OPEN CONTACTS
WML35AA-120A
WML35AA-240A
WML60AA-120A
WML60AA-240A
NOMINAL
INPUT
VOLTAGE
PART
NUMBERS
218
.135
120 VAC
1,200
.063
240VAC, 60HZ
220VAC, 50HZ
3 POLE NORMALLY OPEN CONTACTS
WML35AAA-120A 120 VAC
WML35AAA-240A 240VAC, 60HZ
220VAC, 50HZ
111
430
.220
.117
16.5VA
16.5VA
NOMINAL
INPUT
VOLTAGE
120 VAC
240VAC, 60HZ
220VAC, 50HZ
218
1,200
3 POLE NORMALLY OPEN CONTACTS
28VA
28VA
WML60AAA-120A 120 VAC
WML60AAA-240A 240VAC, 60HZ
220VAC, 50HZ
111
430
16.5VA
.135
16.5VA
.063
.
28VA
.220
28VA
.117
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
.
PAGE 163
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
100 AMP MERCURY DISPLACEMENT RELAYS
MDR
CLASS WM100
CAPABLE OF SWITCHING 100 AMP
LOADS UP TO 480 VAC /48VDC
AVAILABLE IN 1 POLE N.O.
CONTACTS ONLY.
LOAD TERMINALS
AWG #1 THRU #8 WIRE
.187 Dia.
(4.7)
2 Holes
UL Listed
File No. E52197
3.00 Max.
(76.2)
5.87 Max.
(149)
UP
1.87
(4.7)
1.00 Max.
(25.4)
2.09 Max.
(53.0) 3.50 Max.
(88.9)
RECOMMENDED MOUNTING
POSITION ± 10˚
3.37 Max.
(85.59)
SPECIFICATIONS FOR WM100
COIL
60 per minute max.
Frequency of Operation:
80% of nominal voltage, Typ. AC & DC coils.
Pull-in voltage:
78% of nominal voltage, typ. AC coils.
Dropout voltage:
65% of nominal voltage, typ. DC coils.
CONTACTS
Mercury.
Material:
.,001 ohm Typical.
Contact resistance:
TIMING
Operate (at nominal voltage):
Dropout (at nominal voltage):
50 Milliseconds typical.
100 Milliseconds typical.
DIELECTRIC STRENGTH
Across open Contact:
Coil to Contact:
Contact to Frame:
Coil to Frame:
2650 V rms.
2650 V rms.
2650 V rms.
2650 V rms.
TEMPERATURE
Operating:
- 35˚C to + 60˚C Under continuous load.
LIFE
Mechanical (No load):
Electrical (Rated load):
5,000,000 Operations.
100,000 Operations.
MISCELLANEOUS
Insulation Material:
Terminals:
Options:
Weight:
Class B - 130˚C.
# 1 thru 8 AWG wire.
Coil Voltages from 12VAC to 480VAC, 5VDC.
thru 250VDC. Consult Factory.
15.87 ozs. 450 grams.
CONTACTOR RATINGS FOR M100
PART
NUMBERS
1
WM100A-120A
WM100A-240A
WM100A-24D
COIL Measured @ 25˚C
NOMINAL
NOMINAL
NOMINAL NOMINAL
RESISINPUT
CURRENT POWER
TANCE
VOLTAGE
(AMPS)
(OHMS)
POLE NORMALLY OPEN CONTACT
120 VAC
33VA
.275
73.5
240VAC, 60HZ
33VA
.138
300
220VAC, 50HZ
24VDC
10W
.380
53
VOLTAGE
120VAC
240VAC
480VAC
600VAC
24VDC
48VDC
120VDC
250VDC
RESISTIVE TUNGSTEN HORSEPOWER
SINGLE PHASE
AMPS
AMPS
100
100
100
80*
100
100
80
40
100*
60
30*
24*
100
100
80
40
3
5
15
10*
1.5*
1.5*
1.5*
1.5*
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
* NON UL RATING
PART NUMBER SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100 PAGE 164
SERIES
102,103
50 &100 AMP, 2-POLE LIGHTING CONTACTORS
The Series 102 and 103 are solenoid types utilizing a DC coils with a full wave bridge
rectifiers which allows the device to operate from an AC supply. Coil power consumption is less than 10 watts for the series 102, less than 20 watts for the 103. The
contacts are Double make type, each set capable of switching and continuously
carrying at least 50 Amps for the series 102 and 100 Amps for the series 103 at up to
480 volts AC. The contactors are typically constructed and wired to be directly
interchangeable with existing hour meter base with separate wire leads for connection
to the controlling device. Because of their compact construction, these contactors can
be adapted to retrofit almost any existing type. Contact our Factory for details.
6.0 .6)
2
(15
WIRING DIAGRAM
3.0 .2)
(76
6.0
(152.6)
102JXX
103JXX
UP
VOLTAGE
AC (60HZ)
120
240
RECOMMENDED
MOUNTING POSITION
AC CONTACT RATINGS
RESISTIVE LOAD (AMPS)
Series 102 Series 103
200
100
200
100
DC CONTACT RATING
VOLTAGE
(DC)
30
RESISTIVE LOAD (AMPS)
100
200
UNITS WIRED FOR 50 & 100 AMP LAMP LOAD SERVICE
GENERAL SPECIFICATIONS
Struthers-Dunn
ORDERING CODE
Typical Type No.
102
JXX
-110D
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
DC: 80% of nominal voltage measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
60 mS Max. @ Nominal Voltage.
30 mS Max. @ Nominal Voltage.
Series
102 Screw Term., 50 Amp.
103 Screw Term., 100 Amp.
DIELECTRIC STRENGTH
All Mutually Insulated Points: 1500 V rms between all mutually
Insulated current carrying parts and those
parts to ground.
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
Contact Arrangements
TEMPERATURE
Temperature Rating:
JXX- 2 Pole D.M. N.O
Coil Voltage
DC: 6 to 220 (Add "D")
AC, FULL WAVE RECTIFIED: 12 to 240 (Add "A")
WATT HOUR METER BOX NOT SUPPLIED WITH 102/
103 CONTACTOR.
PAGE 165
EXPECTANCY
Mechanical:
Electrical:
-45˚C to +65˚C @ rated operation.
LIFE
TERMINALS
MISCELLANEOUS
Mounting:
Weight:
500,000 Operations no load
100,000 Operations @ Rated Load.
Coil
102 - #8-32
103 - #8-32
Load Term.
#1/4-20
#3/8-18
Wall Mounting..
42 oz., 1.2 kg Grams>
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N
7
7
LATCHING, SEQUENCE
AND
STEPPER RELAYS
5 TO 30 AMPERES
Page 166
Magnecraft
Struthers-Dunn
LATCHING RELAYS TO 10 AMP
250ML
388ML/285
308
255
OCTAL 11 PIN PLUG-IN
PERMANENT MAGNETIC LATCHING
RELAY
PERMANENT MAGNETIC LATCHING
RELAY
2 COIL MECHANICAL
LATCHING.
SINGLE OR DUAL COIL
3 WAY TERMINALS:
SOLDER, 0.187" Q.C.
OR PLUG IN.
RELAY SERIES
FEATURES
DUAL COIL LATCHING
SELF-MAINTAINING
SET AND RESET COILS
MAINTAINS LAST
POSITION WITHOUT
POWER
3 WAY TERMINALS:
SOLDER, 0.187" Q.C.
OR PLUG IN.
AC OR DC COILS
HIGH SENSITIVITY
COILS AVAILABLE
AC OR DC INPUT
CONTACT DATA
CONTACT
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
CONTINUOUS DUTY
COILS
BOTH COILS MAY BE
NO FALSE TRANSFER
ENERGIZED SIMULTAWITH 5 TIMES NOMINAL NEOUSLY WITHOUT
VOLTAGE PULSE
DAMAGE.
SPDT, 3PDT, OR UP TO
4 FORM A, OR FORM B .
DPDT
DPDT
4PDT
10 AMPS @ 120 VAC/
30 VDC
10 AMPS @ 120/240VAC
10 AMPS @ 28 VDC
10 AMPS @ 120, 1/3 HP
10AMPS @ /240, 1/2 HP
10 AMPS @ 28 VDC
SILVER CADMIUM OXIDE
GOLD FLASHED
100 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE
GOLD FLASHED
50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE
50 MILLIOHMS (INITIAL)
SILVER CADMIUM OXIDE
OR GOLD DIFFUSED
50 MILLIOHMS (INITIAL)
1500 V rms
1500 V rms
1500 V rms
1500 V rms
120
12, 24
6 to 240
6 to 125
3.4VA
1.9 WATTS
3.4 VA
1.2 -1.9 WATTS
6 to 240
6 to 125 (250V WITH
SERIES RESISTOR)
5 OP
3 RESET
1.8 OP
1.9 RESET
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
AC OR DC INPUT
SINGLE LEVEL SOCKET
WIRING
30AMPS @ 120
CARRY 10A, BREAK 10A.
30AMPS @ /240
CARRY 10A, BREAK 5A.
30 AMPS @ 125 VDC
CARRY 10A, BREAK 0.5A.
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH:
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (VAC)
WATTS,: (VDC)
24, 120, 240
12 , 24, 110
6 VA
1.64 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
TIMING VALUES
OPERATE:
RELEASE:
- 45˚ C to + 70˚ C
30
30
LIFE
MECHANICAL:
ELECTRICAL:
MILLISECONDS
MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
DIMENSIONS
H
W
L
1.41 x 1.41 x 3.17
APPROVALS
Pending
APPLICATION DATA:
PAGE 169
PAGE NUMBER:
PAGE 170
PAGE 167
- 45˚ C to + 70˚ C
- 45˚ C to + 70˚ C
- 10˚ C to + 60˚ C
25 ms AC/15 ms DC
25 ms AC/15 ms DC
25 ms AC/15 ms DC
25 ms AC/15 ms DC
25 MILLISECONDS
20 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
10 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
1.40 X 1.53 X 1.90
C
H
W
L
1.50 X 1.93 X 1.87
10 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
2.62 X 1.46 X 4.56
US
PAGE 171, 172
PAGE 173, 174
PAGE 175, 176
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
Magnecraft
Struthers-Dunn
LATCHING & STEPPING RELAYS
88L& 88LCP
RELAY SERIES
FEATURES
311
OPEN STYLE OR
ENCLOSED STYLE
SEQUENCE (STEPPING)
RELAY
HEAVY DUTY SEQUENCE
RELAY
DUAL COIL, MECHANICAL
LATCHING.
SINGLE COIL CONTINUOUS DUTY.
POSITIVE ACTION
SEQUENCING CAM
UP TO 6 FORM "C", 3
POLES PER COIL
CONTACT TRANSFER
ON ENERGIZING OR
DE-ENERGIZING
STROKE OF RELAY
FRONT CONNECTED
TERMINALS
AC 50/60HZ, & DC COILS
AVAILABLE
SOLDER TERMINALS OR
20 PIN OCTAL PLUG-IN
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
MATERIAL:
CONTACT
RESISTANCE:
ANY SEQUENCE UP TO 12
STEPS
SINGLE LEVEL SOCKET
WIRING
CONTACT DATA
CONTACT
C85
UP TO 6PDT
DPDT
DPST-NO or NC &
1SPST-NC
0AMP 120VAC
10AMP 240VAC
10 AMP 28VDC
5 AMPS @ 120VAC
5 AMPS @ 28 VDC
0.1 AMPS 125 VDC
20AMP 120VAC
20AMP 240VAC
20 AMP 30VDC
SILVER CADMIUM OXIDE
SILVER CADMIUM OXIDE
FINE SILVER
100 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC
STRENGTH:
1500 V rms
1500 V rms
120
12
6 to 240
6 to 110-125
6VA
2.5
5VA
1.8 WATTS
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
POWER:
VA,: (VAC)
WATTS,: (VDC)
1500 VAC
24 to 550
24 to 240
18VA
14 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE:
- 10˚ C to + 50˚ C (AC)
- 10˚ C to + 60˚ C (DC)
- 10˚ C to + 60˚ C
- 45˚ C to + 65˚ C
TIMING VALUES
OPERATE:
RELEASE:
25 MILLISECONDS
25 MILLISECONDS
35 MILLISECONDS
35 MILLISECONDS
50 MILLISECONDS
50 MILLISECONDS
LIFE
MECHANICAL:
ELECTRICAL:
5 MILLION OPERATIONS
100,000 OPERATIONS
DIMENSIONS
5 MILLION OPERATIONS
100,000 OPERATIONS
H
W
L
1.93 X 1.75X 2.87
H
W
L
2.62 X 1.46X 3.406
PAGE 177, 178
PAGE 179
500,000 OPERATIONS
100,000 OPERATIONS
H
W
L
2.625 X 3.00 X 5.00
APPROVALS
PAGE NUMBER
PAGE 180
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 168
SEQUENCE &
LATCHING RELAY
APPLICATION NOTES
APPLICATION DATA
WHAT IS A SEQUENCE RELAY:
SEQUENCE APPLICATIONS CONTINUED:
A Sequence relay is sometimes called an alternator,
stepper, flip-flop, or impulse relay. The relay has the ability
to open and close it's contacts in a preset sequence. All
sequence relays use a ratchet or catch mechanism to
cause their contacts to change state by repeated impulses
to a single coil. Usually, but not always, one pulse will
close a set of contacts, the next will open them, and so on
back and forth. This alternating of open and closed states
has many possible uses.
A typical example is remotely starting and stopping a
conveyer from a single momentary push button. Several
momentary push buttons might be wired in parallel to
control the conveyer from a number of locations.
A Sequence relay requires a pulsed voltage to the coil
of approximately 50 milliseconds for each sequence to
take place. When the coil is pulsed, the relay armature
moves a lever that in turn rotates the ratchet and cams to
the first position in the sequence. This position will remain
as long as another pulse is not introduced to the coil.
WHAT IS A LATCHING RELAY:
The relay is normally comprised of at least two sets of
contacts to allow the contacts to alternate in combinations
of open and closed states, with each pulse of voltage to
the coil.
One example of possible two pole combinations, would be
where one pole remains open and the other pole is closed
with the first pulse applied to the coil. The second pulse
could then reverse the above sequence. The third pulse
could have both poles closed and the fourth pulse could
open both poles. The above example could also have
other sequences, depending upon the amount of teeth in
the ratchet and the amount of lobes on the cams.
Figure 1 shows an example of how cam placement on the
contact blades can change the position of the contacts as
cams are rotated by the ratchet gear.
Cam 1
Another common use for sequence relays is cascade
starting of multiple HVAC or other high start-up load
systems, to limit the high starting current.
Latch relays typically use a permanent magnet or
mechanical catch to hold the contacts in their last
energized position without the need for continued
application of coil power. They are especially useful in
applications where power must be conserved, such as a
battery operated device, or where it is desirable to have
a relay stay in one position if power is interrupted. They
should not be used to control a device that could create
a safety hazard if it were to restart after a power interruption.
Mechanical latch relays are most often constructed in a
way that will cause them to go to their operate position
when the operate coil is energized regardless of whether
the reset coil is energized or not. This "operate coil
dominant" feature can be useful in applications where a
relay should operate and release like a conventional
relay unless a particular action takes place, at which
time the release coil would drop out, latching the relay in
the operate position. A pallet loader would be a good
example of equipment which might utilize this type of
operation.
Open contact
Cam 2
Closed contact
FIGURE 1
SEQUENCE APPLICATIONS:
Some typical applications for sequence relays is turning
one device on and off from a single momentary contact.
PAGE 169
Magnetic latching relays are typically designed to be
polarity sensitive. When voltage is momentarily applied
to the coil with a predetermined polarity, the relay will
operate. The relay will remain in the operate position
after power is removed from the coil. A permanent
magnetic is designed to hold the contacts in the operate
position without the need for continued power to the coil.
When the polarity is reversed, and momentarily applied
to the coil, the armature will push away from the coil
overcoming the holding affect of the permanent magnetic, causing the contacts to reset. Both single and
dual wound coils use the same principle of operation.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
DUAL COIL, 10 AMP LATCHING RELAYS
250ML
250 ML
MAGNETIC LATCHING RELAY WITH 11 PIN BASE.
OPERATED BY PULSED INPUT AND MAINTAINS LAST POSITION.
CONTACT ARRANGEMENT: DPDT
OUTLINE DIMENSIONS
PENDING
11 PIN PLUG
Artwork marking side
Dimensions are shown in Inch and (Millimeter).
2.89 Max.
(73.4)
2.33 Max.
(59.2)
1.37
(34.79)
6
7
5
8
4
1.37
(34.79)
3
9
2
10
1
11
SPECIFICATIONS CLASS 250 ML
COIL
Operate Voltage::
Reset Voltage:
Duty cycle @ nominal voltage:
Coil resistance:
Max. allowable voltage:
See Table below. (Measured @ 25˚C)
See table below. (Measured @ 25˚C)
Dual coil are intermittent duty.
± 10 % measured @ 25 ˚C
5 X nominal voltage with no false transfer of contacts
during Operate or Reset pulse.
Class "B" system (130˚C) per UL STD. 1446
Coil Insulation:
Duration of Operate & reset pulse: 50 mS Minimum.
CONTACTS
Contact material:
Contact resistance:
Minimum Load:
Contact Rating:
HERMETICALLY SEALED
VERSION AVAILABLE
CONSULT FACTORY
3/16" silver cadmium oxide, gold flashed.
50 milliohms maximum initial resistance at rated current
12 V @ 100 Milliamps
10 Amps @ 120/240 VAC, 28 VDC
1/3 Hp @ 120 VAC, 1/2 Hp @ 240 VAC.
TIMING
Operate time:
Release time:
(AC) 30 mS Max. (DC) 20 mS Max. @ nominal voltage.
(AC) 30 mS Max. (DC) 20 mS Max. @ nominal voltage.
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Pole to pole:
Contacts to frame:
Insulation resistance:
1500 V rms
500 V rms
1500 V rms
1500 V rms
1,000 Megohms min. @ 500 VDC
WIRING DIAGRAM
RESET
(+)
6
5
7
4
(-)
TEMPERATURE
Ambient Temperature (Operating): - 30˚C to +70˚C
- 30˚C to +105˚C
Non operating storage:
8
3
(-)
9
2
10
1
SHOCK RESISTANCE
Latched:
10 G's,
VIBRATION RESISTANCE
Operating:
5 G's, 10 Hz to 55 Hz
MISCELLANEOUS
Enclosure:
Insulation material:
Operating Position:
Weight:
Plastic dust cover with 11 pin octal base.
Molded plastic
Any
170 g ( approx.)
(+)
11
OPERATE
SEE SECTION 10
FOR
MATING SOCKETS
Stock Part Numbers shown also available thru Stocking Distribution
Coil Measured @ 25˚C
PART
NUMBERS
NOMINAL OPERATE
VOLTAGE VOLTAGE
MIN.
DC OPERATED COILS
W250ML2CPX-6
12 VDC
8.4 VDC
W250ML2CPX-7
24 VDC
16.7 VDC
W250ML2CPX-8
110 VDC
77 VDC
AC OPERATED COILS
W250AML2CPX-8 24 VAC
19.2 VAC
W250AML2CPX-9 120 VAC
96 VAC
W250AML2CPX-9 240 VAC
192 VAC
CROSS REFERENCE
COIL
RESET
NOMINAL
TO
VOLTAGE RESISTANCE POWER
IDEC
( EA. COIL)
MIN.
8.4 VDC
16.7 VDC
77 VDC
88/88 Ω
350/350 Ω
4000/4000 Ω
1.64 W
1.64 W
1.64 W
RR2KP-U-DC12
RR2KP-U-DC24
RR2KP-U-DC110
19.2 VAC
96 VAC
192 VAC
52/52 Ω
1200/1200 Ω
3200/3200 Ω
6 VA
6 VA
6 VA
RR2KP-U-AC24
RR2KP-U-AC120
RR2KP-U-AC240
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 170
CLASS
388ML/285
10 AMP MAGNETIC LATCH RELAY
CLASS 388ML/285
10 AMP MAGNETIC LATCH RELAY.
SINGLE OR DUAL COIL LATCHING.
1/3HP @ 120VAC
1/2 HP @ 240VAC
Recognized Component mark for
Canada and the United States.
C
US
UL Recognized
File No. E43641
OUTLINE DIMENSIONS
Dimensions shown are in "Inches" and (Millimeter)
1.53 Max.
(38.8)
1.90Max.
(48.4)
.187 x .020
(4.76 x 0.51)
QC Terminals Typical
1
4
2
5
3
6
7
8
9
1.40Max.
(35.5)
A
B
.28 Typ.
(7.1)
COIL Measured @ 25˚C
CROSS REFERENCE
COIL
NOMINAL OPERATE RESET NOMINAL NOMINAL
TO
CONFIGUEQUIVALENT PART NUMBERS
INPUT VOLTAGE VOLTAGE RESISPOWER POTTER & BRUMFIELD
RATION
TANCE
VOLTAGE (Or Less) (Or Less) (OHMS)
AC OPERATED, SINGLE COIL
SINGLE 120 VAC 102 VAC 102 VAC 10,000
W388AMLCPX-9
KUL11A15S-120
285XBXC-120A
0.8VA
DC OPERATED, SINGLE COIL
W388MLCPX-6
SINGLE 12 VDC 9.0 VDC 9.0 VDC
KUL11D15S-12
285XBXC-12D
120
1.2W
SINGLE 24 VDC 18,0 VDC 18.0 VDC
W388MLCPX-7
KUL11D15S-24
285XBXC-24D
470
1.2W
DC OPERATED, DUAL COIL
W388ML2CPX-6
DUAL
KUL11D15D-12
285XBXCD-12D
12 VDC 9.0 VDC 9.0 VDC 88/88
1.64W
DUAL
W388ML2CPX-7
KUL11D15D-24
285XBXCD-24D
24 VDC 18.0 VDC 18.0 VDC 350/350
1.64W
PART
NUMBERS
STRUTHERS-DUNN
PART NUMBERS SHOWN AVAILABLE THRU STOCKING DISTRIBUTION
PAGE 171
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
10 AMP MAGNETIC LATCH RELAY
388ML/285
SPECIFICATIONS CLASS 388/285
COIL
Pull-in Voltage:
AC: 85%, DC: 75% of nominal voltage
measured at 25˚C
Single coil are continuous duty
dual coil are intermittent duty.
30 Milliseconds
5 x Nominal voltage with no false transfer
of contacts during operate or reset pulse.
110% of nominal voltage
±10% Measured @ 25˚C
Duty Cycle (Nominal V)
Pulse Duration Min.
Max. allowed voltage:
Coil Resistance:
CONTACTS
Contact Material:
Contact configuration:
Contact Rating
Silver Cadmium Oxide, Gold Flashed.
DPDT, (3PDT available)
10 Amps @ 120/240VAC, 28VDC
TIMING
Operate Time: (@ Nom. V)
Release Time: (@ Nom. V)
AC: 30 mS max., DC: 20 mS max.
AC: 30 mS max., DC: 20 mS max.
DIELECTRIC STRENGTH
Across open contacts
between current carrying
parts to ground:
Insulation Resistance:
500 V rms
1500 V rms
500 VDC Exceeds 1000 Megohms.
TEMPERATURE
Temperature Rating:
AC: -45˚C to +70˚C @ Rated Operation.
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear polycarbonate
87 grams approx.
WIRING DIAGRAM
VIEWED FROM PIN END
RESET
3
1
1
6
4
4
3
3
1
6
4
5
9
7
A
+
RESET
B
7
COMMON
-
+
OPERATE
SINGLE COIL ( DC )
RESET 9
8
OPERATE
B
A
-
SINGLE COIL ( AC )
VIEWED FROM TERMINAL END
-
6
9
+
8
A
B
OPERATE
7
-
+
OPERATE
DUAL
COIL ( DC )
SEE SECTION 10
FOR
MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 172
SERIES
MAGNETIC LATCH 10 AMP, 4 POLE RELAY
308
The series 308 relay combines the basic features of the 284 series relay into a
permanent magnet latch relay. It is available with a single wound AC or DC coil.
To operate the single-wound DC coil, voltage of proper polarity is applied to the coil,
and reset when the polarity is then reversed. For AC coils, power is applied through
the operate diode or the reset diode to provide the required function.
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (millimeters)
0.218
(5.53)
1.50
(38.1)
1.31
(33.3)
MANUAL PUSH
BUTTON
ACTUATOR (OPTIONAL)
1.93
(49.0)
1.87
(47.4)
0.28
(7.11)
0.187
(4.74)
WIRING DIAGRAM
(VIEWED FROM TERMINAL END)
Struthers-Dunn
ORDERING CODE
Typical Type No.
308 XDX C LMY -120A
Series
308 3 way terminals, Magnetic
latch, 10 Amp, 4 pole
Contact Arrangements
XDX (4 Form "C")
Construction Style
Enclosed, 3 way terminals - CODE C
Options
10 Amp contacts Standard - NO CODE
Gold diffused contacts - CODE G
Indicator Lamp - CODE L
Manual Actuator - CODE M
Printed Circuit Terminals - CODE T
5 Amp contacts (Silver) - CODE Y
Coil Voltage
AC: 6, 12, 24, 48, 120, 240 (Add "A")
DC: 6, 12, 24, 48, 115, 125 (Add "D")
-
1
5
2
6
3
7
9
11
10
OPERATE
13
4
8
12
14
+
RESET
SINGLE COIL DC OPERATED
1
5
2
6
3
7
4
8
9
10
11
12
+
-
OPERATE
COMMON
13
14
RESET
SINGLE COIL AC OPERATED
Dual Coil Construction available. Consult Factory.
PAGE 173
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
MAGNETIC LATCH 10 AMP, 4 POLE RELAY
SERIES
308
GENERAL SPECIFICATIONS
COIL
Pull-in Voltage:
Dropout Voltage:
Max. allowed voltage:
Coil Resistance:
AC: 85%, DC: 75% of nominal voltage
measured at 25˚C
10% of nominal voltage or more @ 25˚C
110% of nominal voltage
±10% Measured @ 25˚C
CONTACTS
Contact Material:
Silver Cadmium Oxide.
TIMING
Operate Time:
Release Time:
AC: 25mS,
AC: 25mS,
DC: 15mS @ nom. Voltage
DC: 15mS @ nom. Voltage
DIELECTRIC STRENGTH
All Mutually Insulated Points: 500 V rms across open contacts
1500 V rms between current carrying
parts
Insulation Resistance:
500 VDC Exceeds 1000 Megohms.
TEMPERATURE
Temperature Rating:
LIFE
EXPECTANCY
Mechanical:
Electrical:
MISCELLANEOUS
Enclosure:
Weight:
-45˚C to +70˚C @ Rated Operation.
10 Million Operations no load
100,000 Operations @ Rated Load.
Clear polycarbonate
5.0 oz. approx..
CONTACT RATINGS
LOAD
Resistive Motor
Load 80% pF.
30VDC
120VAC
240VAC
10A
10A
1/3Hp
10A
1/2Hp
Maximum total load for 4 pole relays is 30 Amps @
120 VAC, 20 Amps @ 240 VAC.
COIL SPECIFICATIONS @ 25˚C
Nominal
Voltage
6
12
24
48
120AC or
115-125DC
240AC*
Resistance
Resistance
Ohms ± 10% Ohms ± 10%
DC
AC
3
30
12
120
48
480
1920
870
8200
4700
-*
Current (MA)
AC
560
230
115
31
DC
200
100
50
25
13-15
Power
Consumption
AC
DC
3.4VA 1.2W
3.4VA 1.2W
3.4VA 1.2W
3.4VA 1.2W
3.4VA 1.9W
12
-*
3.4VA 1.9W
NOTE: For 220 VDC to 250 VDC coils, use a 8,200 Ω, 5 Watt resistor in series with
110 VDC to 125 VDC relay coils.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 174
SERIES
B255
300 VOLT LATCHING PLUG-IN RELAYS
THE SERIES B255 IS A TWO COIL LATCHING VERSION OF THE GENERAL PURPOSE
TYPE 219 RELAY. WHEN THE OPERATE COIL IS MOMENTARILY ENERGIZED, THE
RELAY MECHANICALLY LATCHES IN THE ENERGIZED POSITION AND REMAINS IN THE
ENERGIZED POSITION WITH THE POWER REMOVED FROM THECOIL. THE SECOND
COIL WHEN MOMENTARLY ENERGIZED, PROVIDES ELECTRICAL RESET OF THE
CONTACTS. ALL CONTACTS OPERATE FROM A COMMON ARMATURE TO PREVENT
CONTACT OVERLAPPING. COILS ARE RATED FOR CONTINUOUS DUTY. NUCLEAR
QUALIFIED VERSIONS ARE AVAILABLE. CONTACT THE FACTORY FOR DETAILS.
UL Recognized
File No. E13224
R
R
OUTLINE DIMENSIONS
Dimensions shown Inch & (Millimeters)
4.56
(115.8)
LOCKING DEVICE
PAGE 175
TYPE
RESET
OPERATE
7
6
RESET
12
1
SEE SECTION 10
FOR
MATING SOCKETS
B255BXBP
(2 N.O. + 2 N.C. )
1
RESET
RESET
12
1
6
OPERATE
6
7
DPDT + 1 NO
DPDT
3PDT
2 NO + 2 NC
12
7
B255ABXP
(DPDT + 1 N.O. )
SUFFIX
U
V
LM
33
CONTACTS
B255ABXP
B255XBXP
B255XCP
B255BXBP
B255XCXP
(3 PDT)
OPERATE
OPTIONS
130˚C Coil
Coil Suppression
Light & Actuator
Fine Silver-Gold Diffused Bifurcated Contacts
1
6
Note: For time delay on energizing reset coil,
specify 256 series in lieu of B255
DC RELAYS, 1.8 WATTS (2.5 W @ 125VDC)
12
B255XBXP
(DPDT )
P LM -
Series
B255 2 Coil Latch plug-in
Contact Arrangements
XBX DPDT
XCX 3PDT
ABX SPST-NO & 2 Form C
BXB DPST-NO & 2 Form B
Standard Features
Polycarbonate Cover- CODE "P"
Optional Features
Indicator Lamp across both coils - CODE "L"
Manual Actuator- CODE "M"
Perm. Magnet Blowout- CODE "69"
Coil Voltage
Coil Voltages & Frequencies must be specified.
1
(VIEWED FROM TERMINAL END)
OPERATE
B255 XCX
2.625
(66.67)
WIRING DIAGRAMS
Struthers-Dunn
ORDERING CODE
Typical Type No.
7
1.468
(37.28)
6
3.75
(95.25)
7
12
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
300 VOLT LATCHING PLUG-IN RELAYS
SERIES
B255
GENERAL SPECIFICATIONS
COIL
Pull-in, min. AC
Pull-in min. DC
Overvoltage, max.
85% of Nominal Voltage
80 % of Nominal Voltage
110% of nominal, voltage
CONTACTS
Contact Material:
Silver Cadmium Oxide, & Gold Diffused
(Standard)
TIMING
Operate Time: (operate coil)
Release Time: (Reset coil
energized)
25 mS Max. @ Nominal Voltage.
20 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
All Mutually Insulated Points:
Insulation :
1500 V rms
1/4" over surface, 1/8" thru Air
TEMPERATURE
Rated Operation:
-10˚C to +60˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
500,000 Operations 1/2 Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear polycarbonate.
215 g (7.58 oz.) APPROX.
UL Recognized
File No. E13224
R
R
COIL SPECIFICATIONS @ 25˚C
*AC COIL, 50/60 HZ
RESET COIL (3VA) OPERATE COIL (5VA)
Nominal Resistance Coil Power Resistance Coil Power
Ohms
(mA)
(mA)
Voltage Ohms
± 10%
± 10%
1.10
3.0
6
840
800
4.20
14.5
12
256
410
15.5
52.0
24
150
200
540
1450
120
26.5
45.0
1815
5000
240
4.8
13.2
Current inrush on all AC coils is less than twice the listed
milliamperes ratings as shown in the AC coil data table.
*Currents shown in table measured at 60 Hz.
DC COIL DATA
OPERATE COIL (1.8W)
Resistance Coil Power
Ohms
(mA)
± 10%
15.5
385
63.5
189
250
96.0
6200
20.0
DC relays, 1.8 Watts (2.5 W @ 125VDC)
RESET COIL 1.4W)
Nominal Resistance
Coil Power
Voltage Ohms
(mA)
± 10%
21.0
6
286
85.0
12
141
300
24
80
115/125 8000
14.4
CONTACT RATINGS
BREAK
MAKE CARRY RESISTIVE INDUCTIVE
VOLTS
24 VDC
120 VAC
240 VAC
28 VDC
125 VDC
30A
30A
30A
30A
30A
10A
10A
10A
10A
10A
10A
10A
5A
10A
0.5A
10A
3A
1A
3A
0.1A
** For versions with suffix "69"
Permanent Magnet Blowouts
125 VDC
125 VDC
250 VDC
250 VDC
SM
DM
SM
DM
30A
30A
30A
30A
10A
10A
10A
10A
1.5A
4A
0.5A
1.5A
0.5A
1.5A
150 mA
0.5A
**Relays with Code 69 feature ( Check with factory for UL & CSA Listing).
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 176
CLASS
DUAL COIL, 10 AMP LATCHING RELAYS
88L
CLASS 88L
OPEN STYLE DUAL COIL
LATCHING RELAY
RATED 10 AMPS
OUTLINE DIMENSIONS
Dimensions shown Inchs & (Millimeters)
2.87 Max.
(72.9)
1.37 Max.
(34.8)
1.75 Max.
(44.45)
NOTE: Applying a momentary pulse to that coil which
was NOT LAST ENERGIZED, will cause a transfer of
all contacts. The mechanical latch will maintain all contacts
in the last transferred position even after the coil is deenergized or power is interrupted. Re-transfer of contacts
can be accomplished by a momentary pulse to the other coil.
.156 Dia.
(3.96)
1.00 Typ.
(25.4)
2.37 Max.
(60.2)
2.68 Max.
(68.07)
1.93 Max,
(49.0)
.130
(3.30)
.100
(2.54)
CLASS 88LCP
ENCLOSED STYLE DUAL
COIL LATCHING RELAY
RATED 10 AMPS
WIRING DIAGRAMS
Shown from Pin End
2.375
(60.3)
3.562
(90.47)
1.75
(44.45)
11
7 9 10
13
8 12
6
14
5 4
15
16
2 20 17
3
18
1
19
20 Pin Octal Socket mates with
Magnecraft chassis mount socket
70-454 or equivalent.
5PDT
PART NUMBER 70-454, 20 PIN SOCKET AVAILABLE.
CALL FACTORY FOR CURRENT QUOTE.
PAGE 177
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
DUAL COIL, 10 AMP LATCHING RELAYS
CLASS
88L
SPECIFICATIONS CLASS 88L RELAYS
COIL
Pull-in voltage:
Coil resistance:
Nominal power:
Duty:
80% of nominal voltage or less. for DC coils
85% of nominal voltage or less for AC coils
50/60 Hz operation, Measured @ 25˚C
± 10 % measured @ 25 ˚C
6VA for AC coils, 3 Watts for DC coils.
Intermittent actuation. min. pulse time 50mS @
nominal voltage. Max. pulse time 2 Minutes for
AC coils, 5 Minutes for DC coils.
CONTACTS
Contact material:
Contact resistance:
3/16" silver cadmium oxide, gold flashed.
50 mΩ max. initial resistance @ rated current
TIMING
Operate time:
Release time:
25 mS or less at nominal voltage.
25 mS or less at nominal Voltage.
DIELECTRIC STRENGTH
Contacts to coil:
Across open contacts:
Pole to pole
Contacts to frame:
Insulation resistance:
1500 V rms
1000 V rms
1500 V rms
1500 V rms
1000 megohms min. 500 VDC
TEMPERATURE
Ambient Temperature (Operating):
Non operating (storage):
-10˚C to +50˚C (AC), -10˚C to +60˚C (DC)
-30˚C to 105˚C
SHOCK RESISTANCE
Operating:
Non operating:
5 G's
20 G's
VIBRATION RESISTANCE
Operating
Non operating:
5 G's, 10 Hz to 55 Hz
5 G's, 10 Hz to 55 Hz
MISCELLANEOUS
Mounting:
Insulation material:
Terminals
Enclosure:
Operating Position:
Weight:.
6 holes, 5/32" dia.for mounting plate to flat surface
or 20 pin style plug-in.
Fiberglass melamine
Open style are Solder type standard, will also accept Q.C. terminals
size .110. (Amp "Faston" or equivalent) Enclosed styles have 20
nickel plated brass pins
"See-through " clear, polycarbonate plastic.
Any
Open Style: 6-1/2 ozs. 184.3 grams approx..
Enclosed style: 8 ozs. 226.8 grams
COIL Measured at 25˚C
CROSS REFERENCE
CONTACT
NOMINAL
TO
CONFIGU- NOMINAL RESISTANCE NOMINAL
POWER POTTER & BRUMFIELD
RATION VOLTAGE
(OHMS)
AC OPERATED, OPEN STYLE, SOLDER TERMINAL
_
4PDT
120 VAC
KB-17AG-120
6 VA
W88ALX-4
PART
NUMBERS
DC OPERATED, OPEN STYLE, SOLDER TERMINAL
50Ω
4PDT
12 VDC
88LX-2
AC OPERATED, ENCLOSED 20 PIN OCTAL PLUG-IN
_
120 VAC
5PDT
88ALCPX-23
2.4W
KB-17DG-12
6 VA
KBP-20AG-120
Stock Part Numbers shown below also available thru stocking distriubution
Part Numbers without a "W" prefix are Non-Stock Relays .
Other AC & DC coil voltages and contact combinations up to 6
poles are available on special order. Consult Factory
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 178
SERIES
INDUSTRIAL PLUG-IN SEQUENCE (STEPPER), 5 AMP
A311
The A311 Series Relay is a sequencing version of the 219 series
general purpose relay. Contacts transfer on each Impulse to the coil.
Models are available with contacts transferring when coil is energized
or when de-energized. A double cam movement, one cam per snap
switch, allows one or both contacts to be energized or de-energized
with the cam rotating one half-step when the coil is energized and the
other half step when the coil is de-energized assures reliable sequencing
of the two SPDT snap switches.
2.625
(66.6)
2.593
(65.5) 3.406
(86.5)
.435
(11)
LOCKING
CLIP
WIRING DIAGRAM
Viewed from Pin Side
1
7
12
12
11
10
9
8
7
1
2
3
4
5
6
OPERATE
6
A311XBXP
A311XBXPR *
(DPDT )
CONTACT RATINGS
LOAD
120VAC
Resistive
Max. Inrush
5A
12A
ORDERING CODE
Typical Type No.
30VDC
115VDC
5A
12A
0.1A
0.25A
GENERAL SPECIFICATIONS
85% of Nominal Voltage
80 % of Nominal Voltage
110% of nominal, voltage
Silver Cadmium Oxide
TIMING
Operate Time: (operate coil)
35 mS Max. @ Nominal Voltage.
Release Time: (Reset coil energized) 35 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Across open Contacts:
Between mutually insulated current
carrying parts & those parts to ground:
Insulation Resistance :
500 V rms
1500 V rms
1000 MΩ min. @ 500 VDC
Struthers-Dunn
TEMPERATURE
Rated Operation:
-10˚C to +60˚C
A311 XBX P R L -120A
LIFE EXPECTANCY
Mechanical:
Electrical:
5 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear polycarbonate.
190 g (6.70 oz.) approx.
Series
A311 Industrial plug-in ,
Sequence Relay, 5 Amp, DPDT
Contact Arrangements
XBX ( 2 Form C)
Standard Features
Plug-in with Polycarbonate Cover - CODE P
Contact Transfer
When coil is energized - NO CODE
when coil is de-energized CODE R
Options
Indicator Lamp - CODE L
Coil Suppression - CODE V
Coil Voltage
AC: 6, 12, 24, 120, 240 (Add "A")
DC: 6, 12, 24, 48, 110-125 (Add "D")
SEE SECTION 10
FOR
MATING SOCKETS
PAGE 179
UL Recognized
File No. E7104
COIL
Pull-in, min. AC
Pull-in min. DC
Overvoltage, max.
CONTACTS
Contact Material:
*Transfer on Release
1.468
(37.2)
COIL SPECIFICATIONS @ 25˚C
AC COIL , 50/60Hz
Nominal Resistance
Voltage Ohms
± 10%
1.1
6
4.2
12
15.5
24
540
120
1815
240
DC COIL
Nominal
Voltage
6
12
24
48
110-125
Resistance
Ohms
± 10%
15.5
63.5
250
970
6200
NOTE: Relays with other coil characteristics may be supplied
to meet specific application requirements.
250VDC operation may be obtained by wiring a 6,200 Ω,
5 Watt resistor in series with the 110-125VDC coil. The
resistor must be mounted external to the A311.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
SCREW TERMINAL SEQUENCE RELAY, 20 AMP, 2 POLE
C85
The C85 Series Relay is a base mounted, screw terminal, open style sequencing relay.
This two pole relay has a single coil which operates a ratchet wheel. Control cams, on the
ratchet wheel shaft, step from one position to the next on each Impulse to the coil. A 50
millisecond pulse will step the relay. Coils are for momentary duty only. The C85 may be
supplied in any sequence up to 12 steps. Contacts are single throw.
5.00
(127)
3.00
(76.2)
2.62
(66.5)
WIRING DIAGRAM
2.37
(60.1)
.312
(7.92)
4.37
(110.9)
.312
(7.92)
GENERAL SPECIFICATIONS
COIL
Pull-in, min. AC
Pull-in min. DC
Overvoltage, max.
CONTACTS
Contact Material:
85% of Nominal Voltage
80 % of Nominal Voltage
110% of nominal, voltage
Fine Silver
TIMING
Operate Time: (operate coil)
50 mS Max. @ Nominal Voltage.
Release Time: (Reset coil energized) 50 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Across open Contacts:
Between mutually insulated current
carrying parts & those parts to ground:
Insulation Resistance :
STANDARD CONTACT SEQUENCES
1500 V rms
1500 V rms
1000 MΩ min. @ 500 VDC
TEMPERATURE
Rated Operation:
-45˚C to +65˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
500,000 Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Terminals:
Mounting:
Weight
RELAY
STEP
CONTACT A
C85AXA
CONTACT B
CONTACT A
C85BXX
CONTACT B
0 = CONTACT OPEN
# 10-32 Studs with Hardware
3 clearance holes for # 8 screws
325 g (11.46 oz.)
Struthers-Dunn
ORDERING CODE
Typical Type No.
CONTACT RATINGS
C85
AC
DC
24VAC
20A
20A
120VAC 240VAC
20A
1.0A
10A
0.25A
COIL SPECIFICATIONS @ 25˚C
AC COIL , 50/60Hz
Nominal Resistance
Voltage Ohms
± 10%
27
24
771
120
110-125
3,290
240
14,700
440
22,000
550
DC COIL
Resistance
Ohms
± 10%
62
24
120
110-125 1,475
6,100
240
440
550
Nominal
Voltage
1 2 3 4 (REPEAT)
0 X 0 X
X 0 X 0
0 X 0 X
0 X 0 X
X = CONTACT CLOSED
C85 AXA H3 -120A
Series
C85 Screw Terminal
Sequence Relay, 20 Amp, 2 Pole
Contact Arrangements
AXA 1 S.B.-N.O. & 1 S.B.-N.C.
BXX 2 S.B.-N.O.
Options
Open style construction - NO CODE
Sheet Metal Housing (consult Factory)
For Dimensions) -CODE H3
7, 9, 10, 11, 12 Tooth ratchet-Consult Factory
Coil Voltage
AC: 24, 120, 240, 440, 550 (Add "A")
DC: 24,110-125, 240 (Add "D")
RATCHETS: 8 Tooth Standard. ( 7, 9, 10, 11, and 12 are
Special Order). Consult Factory.
Non-Standard Coils, Specify requirement, Consult Factory.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 180
S E C T I O N
8
8
HIGH VOLTAGE
ELECTROMECHANICAL AND REED
RELAYS
5KV TO 10KV
Page 181
Magnecraft
Struthers-Dunn
HI-VOLTAGE RELAYS 5KV TO 10KV
158
RELAY SERIES
102V
102HV
5000 V0LTS
5000 V0LTS
FEATURES
SWITCHES LOADS UP TO 1KVA.
@ 5000 VOLTS
DESIGNED WITH A UNIQUE
DOUBLE MAKE & BREAK CONTACT
DESIGN WITH GAP OF 0.40".
EXCELLENT HIGH VOLTAGE ARCOVER RESISTANCE BETWEEN
CONTACTS.
SOLDER TERMINAL DESIGN.
10,000 V0LTS
EPOXY SEALED FOR EXTRA
PROTECTION FROM HIGH
VOLTAGE ARC- OVER
EPOXY SEALED FOR EXTRA
PROTECTION FROM HIGH
VOLTAGE ARC OVER
CHASSIS MOUNTING
WITH SOLDER TERMINALS.
CHASSIS MOUNTING WITH
SOLDER TERMINALS.
EXTRA WIDE SEPARATION
BETWEEN COIL AND OUTPUT
CONTACTS.
EXTRA WIDE SEPARATION
BETWEEN COIL AND OUTPUT
CONTACTS.
SWITCHES UP TO 10 MILLIAMP SWITCHES UP TO 5 MILLIAMP
LOADS @ 10,000 V
LOADS @ 5000 V
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CAPACITANCE (No shield)
Across open contacts:
CONTACT MATERIAL:
CONTACT
RESISTANCE:
SPST-NO
SPDT-DB-DM
1 KVA, 5000 VDC
200 mA, 5000 V
1 Amp, 1000 V
SILVER ALLOY GOLD FLASHED
100 MILLIOHMS (INITIAL)
SPST-NO
50VA, 5000 VDC
10 mA
50VA, 10,000 VDC
5 mA
2.0 pf
TUNGSTEN
2.0 pf
TUNGSTEN
200 MILLIOHMS (INITIAL)
200 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH
Across open contacts:
7,500 V rms & contacts to ground
6,000 VDC
12,000VDC
6,000 VDC
12,000 VDC
NOT AVAILABLE
6, 12, 24 VDC
500-580 mW
NOT AVAILABLE
24 VDC
1.5 WATTS
3,000 V rms
Coil to ground:
Between all mutually
insulated points:
8,500 V rms
COIL DATA
AC - VOLTAGE:
DC - VOLTAGE:
WATTS,: (VDC)
AVAILABLE
24 VDC
5 WATTS
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
STORAGE
TIMING
OPERATE:
RELEASE:
BOUNCE:
SHOCK (Non-operating):
VIBRATION:
LIFE
MECHANICAL:
ELECTRICAL:
DIMENSIONS
- 40˚C to + 85˚ C
- 40˚C to + 85˚C (1 Form A)
- 40˚C to + 40˚C (1 Form B)
-60˚C to + 105˚C
- 40˚C to + 85˚ C
10 G's -11mS, 1/2 sinewave
10 G'S - 10 to 55 HZ
3 MILLISECONDS
2 MILLISECONDS
2.0 MILLISECONDS
30 G's -11mS 1/2 sinewave
10 G's - 10 to 1000 HZ
3 MILLISECONDS
2 MILLISECONDS
2 MILLISECONDS
30 G's - 11mS, 1/2 sinewave
10 G's -10 to 1000 HZ
5 MILLION OPERATIONS
100,000 OPERATIONS
10 MILLION OPERATIONS
1,000,000 OPERATIONS
10 MILLION OPERATIONS
1,000,000 OPERATIONS
-60˚C to + 105˚C
45 MILLISECONDS
20 MILLISECONDS
H
W
L
H
W
L
2.28 X 2.21 X 3.12
0.75 X .875 X 4.50
PAGE 183
PAGE 184
-60˚C to + 105˚C
H
W
L
0.75 X .875 X .450
APPROVALS
PAGE NUMBER
PAGE 184
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 182
CLASS
158
HIGH VOLTAGE SWITCHING RELAYS
CLASS 158
SPDT-DB-DM CONTACT CONFIGURATION
SWITCHES LOADS UP TO 1KVA
SPECIFICATIONS CLASS 158
COIL
Coil Dissipation:
DC 5 Watts.
CONTACTS
Contact Material:
Silver alloy, Gold Flashed, 1/4" dia.
Contact Configuration:
SPDT-DB-DM
Switching Voltage max.: 5000 VDC
Contact Rating:
OUTLINE DIMENSIONS
DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS)
1.750
(44.45)
.196 ( 4.98) dia.
2 Holes
1.125
(28.58)
200 mA @ 5000 VDC
1 Amp @ 1000 VDC
DIELECTRIC STRENGTH
Across open contacts:
Contact to Coil:
Contact to Frame:
Insulation Resistance:
7500 V rms
8500 V rms
3000 V rms
500 VDC, Exceeds 100 MΩ
TEMPERATURE
Operating:
-40˚C to +85˚C
LIFE EXPECTANCY
Electrical:
Mechanical:
100,000 ( Rated Load)
5 Million Operations (No Load) Min.
MISCELLANEOUS
Mounting:
Weight:
Bracket with 2 Clearance holes 0.196 dia.
212.6 grams (7.48 oz.)
3.125 Max.
(79.38)
WIRING DIAGRAM
VIEWED FROM PIN END
FIELD
INSTALLABLE
JUMPER
WIRE
2.281
(57.94)
2.281
(56.34)
SPDT-DB-DM
PART
NUMBERS
W158HVX-1
SPDT
Coil Measured at 25˚C
CONTACT
NOMINAL
CONFIGURA- NOMINAL
NOMINAL
INPUT
COIL
TION
VOLTAGE RESISTANCE POWER
SPDT-DB-DM
24VDC
120
5 Watts
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
PAGE 183
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
HIGH VOLTAGE SWITCHING RELAYS
102V
CLASS 102V
EPOXY ENCAPSULATED HIGH VOLTAGE REED.
SPST-NO TUNGSTEN CONTACTS
SWITCHES LOADS UP 10 mA @ 5000 Volts DC
CLASS 102HV
Same as above except:
Switches 10,000 Volts with Loads up to 5 mA DC
OUTLINE DIMENSIONS
DIMENSIONS SHOWN ARE IN INCHES AND (MILLIMETERS)
4.50
(114.3)
4.12
(104.7)
0.875
(22.2)
3.40
(86.5)
.156 dia.
(3.9)
0.75
(19.0)
.645
(16.3)
0.25
(6.35)
1.50
(38.1)
1.10
(27.9)
Coil Terminals
.125 x .025
.125
0.28
(3.18)
(7.1)
0.08
(2.03) DIA.
Typical.
Do not hook wire heavier than #22 AWG. Excess stress on
terminals could cause damage to internal components
PART
NUMBERS
CONTACT
NOMINAL
CONFIGURAINPUT
TION
VOLTAGE
Coil Measured at 25˚C
NOMINAL
NOMINAL
COIL
POWER
RESISTANCE
5,000 VOLTS NORMALLY OPEN
500 mW
70 Ω
W102VX-49 SPST-NO
6 VDC
580 mW
250 Ω
W102VX-50 SPST-NO
12 VDC
580 mW
1000 Ω
W102VX-51 SPST-NO
24 VDC
10,000 VOLTS NORMALLY OPEN
1.5 Watts
400 Ω
W102HVX-3 SPST-NO
24 VDC
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
NOTE: Other voltages and contact combinations available. Contact Factory.
Pull-in is measured at 75% of nominal voltage or less, at 25˚C
Weight: 49.2 grams, (1.74 oz.)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 184
S E C T I O N
9
9
SENSITIVE
LOW INPUT POWER
RELAYS
2 TO 5 AMPERES
Page 185
Magnecraft
Struthers-Dunn
SENSITIVE RELAYS 2 TO 5 AMP
RELAY SERIES
FEATURES
112, 112PGF
67S
LOW POWER DESIGN
REQUIRES AS LITTLE AS
11.4 mW or 51.7 mW OF
DC COIL POWER.
SOLDER/PLUG-IN WITH A
3-38 UNC MOUNTING
STUD.
AVAILABLE WITH AC OR
DC COILS.
UP TO 4 POLES WITH
STANDARD SILVER, GOLD
OVERLAY CONTACTS
CAN WITHSTAND 5 TO
10 TIMES COIL RATING UP
TO 300 VOLTS
219 STYLE PLUG-IN OR
OPEN STYLE
CHASSIS OR PC STYLE
SOCKETS.
292
392
LOW POWER DC RELAY
125mW PER POLE.
LOW POWER DC RELAY
125 mW PER POLE
OPERATES OVER A
3 WAY SOLDER TERMIWIDE VOLTAGE RANGE. NALS, .187 Q.C./ PLUG-IN.
OCTAL STYLE PLUG-IN
OPERATES OVER A
FITS STANDARD 8 OR 11 WIDE VOLTAGE RANGE.
PIN OCTAL SOCKETS
FITS STANDARD 283/388
STANDARD SOCKETS.
INDUSTRY STANDARD
FOOTPRINTS.
CONTACT DATA
CONTACT
CONFIGURATION:
MAXIMUM ALLOWABLE
CONTACT LOAD:
CONTACT
CONTACT
MATERIAL:
RESISTANCE:
SPDT, DPDT
SPDT TO 4PDT
2Amps @ 120 VAC
1 Amp @ 240 VAC
2 Amps @ 30 VDC
FINE SILVER
3 AMP
@ 120 VAC/30 VDC
50 MILLIOHMS (INITIAL)
SPDT TO 3PDT
5 Amps
@ 120 VAC/30 VDC
5 Amps
@ 120/240 VAC,
28 VDC
SILVER
SILVER
SILVER, GOLD OVERLAY
50 MILLIOHMS (INITIAL)
SPDT TO DPDT
50 MILLIOHMS (INITIAL)
50 MILLIOHMS (INITIAL)
INSULATION
CHARACTERISTICS
DIELECTRIC STRENGTH
Across open contacts:
Between all mutually insulated
current carrying parts and
those parts to ground:
500 V rms
500 V rms
500 V rms
500 V rms
1,500 V rms
1,500 V rms
1,500 V rms
1,500 V rms
1.0 to 225
0.08 to 21.0 mA
NOT AVAILABLE
4.5 to 13.7 mA
NOT AVAILABLE
15 to 139 mA
11.1 to 35 mA
NOT AVAILABLE
15 to 139 mA
11.1 to 35 mA
1 pole 0.2VA, 2 pole 1.0VA
1 pole 15mW, 2 pole 52mW
85 to 200 mW
125 mW Per pole
125 mW Per pole
COIL DATA
AC - VOLTAGE:
DC - CURRENT:
POWER
AC VA:
MILLIWATTS DC:
GENERAL DATA
AMBIENT TEMPERATURE
OPERATIONAL:
TIMING
OPERATE:
RELEASE:
LIFE
MECHANICAL:
ELECTRICAL:
OPTIONS:
DIMENSIONS
- 45˚C to + 65˚ C
20 MILLISECONDS
20 MILLISECONDS
500,000 OPERATIONS
100,000 OPERATIONS
Special Pick-up and
Dropout adjustments.
Series coils to 50 Amp.
H
W
L
3.62 X 1.46X 2.62
- 55˚ C to + 70˚ C
18 MILLISECONDS
8 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
Up to 8PDT @ 50 mW per
pole. P.C. Terminals,
Bifurcated contacts.
Epoxy
H
W
L
.735 X .1.158 X 1.20
- 45˚C to +70˚ C
20 MILLISECONDS
15 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
Indicator lamp (125 VDC only)
Manual Actuator.
H
W
- 45˚C to + 70˚ C
20 MILLISECONDS
15 MILLISECONDS
10 MILLION OPERATIONS
100,000 OPERATIONS
Indicator lamp (125 VDC only)
Manual Actuator. P.C. socket,
Q.C. socket. Stud or bracket
mount. Gold diffused contacts.
L
2.81 X .1.37 X 1.37
H
W
L
2.813 X 1.37 X 1.37
APPROVALS
PAGE NUMBER
PAGE 187, 188
PAGE 189
PAGE 190
PAGE 191, 192
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 186
SERIES
112, 112-PGF 2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN
The 112 and 112-PGF Series of very low coil power relays, perform the same function
but differ in physical packaging and terminations. Each is available with SPDT or DPDT
contact arrangements. The coils require as little as 11.4 mW or 51.7 mW of DC coil power
respectively. All 112's are available with AC or DC coils. AC coils can withstand 5 times
their minimum rating, while DC coils can withstand 10 times their minimum rating, up to
300 volts. One application for this relay is to detect high resistance grounds which could
have low leakage current.
OUTLINE DIMENSIONS
WIRING DIAGRAMS
Viewed from Pin end
Dimensions are shown in INCHES and (MILLIMETERS)
Removable cover with top screw for
field adjustment of pull-in.
112XAX-PGF
(SPDT )
2.625
(66.6)
6
1
7
12
2.593
(65.5) 3.406
(86.5)
112XBX-PGF
(DPDT)
6
1
7
12
.435
(11)
LOCKING
CLIP
12
11
10
9
8
7
1
2
3
4
5
6
1.468
(37.2)
112-PGF Relays have front
removable covers. When
cover is removed the relay
can be adjusted without being
plugged in.
0.10 Dia. x .435 (2.54 x 11)
Typical of all Pin Dimensions
Struthers-Dunn
ORDERING CODE
Typical Type No.
112 XBX PGF Specify Coil
separately
Series
A112 base mounted, low coil power,
1 Form "C"
112 Low coil power, 1 & 2 Form "C"
plug-in , 2 Form "C" base mount.
Contact Arrangements
XAX-SPDT (use with A112 base mount
or 112-PGF)
XBX - DPDT
AXX SPST-NO (use with A112 base
mount or 112-PGF
BXX- DPST-NO
AXA - SPST-NO +SPST-NC
Construction Style
Base mounted open style - NO CODE
Industrial Plug-in, Polycarbonate cover,
front removable - CODE PGF
Coil Voltage
Because of the wide variety of coils, both voltage
and current to choose from, specify as a separate
item.
OPTIONS (CONSULT FACTORY)
PAGE 187
DIMENSIONS & WIRING DIAGRAMS
Front View
A112XAXBase mounted
open style
(SPDT )
A112XBXBase mounted
open style
(DPDT )
2.125
(53.97)
1.875
(47.62)
1.375
(34.92)
2.125
(53.97)
2.625
(66.67)
2.625
(66.67)
.625
(15.87)
2.375
(60.32)
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
2 AMP, LOW COIL POWER, 1 & 2 POLE PLUG-IN 112, 112-PGF
GENERAL SPECIFICATIONS 112, 112-PGF
COIL
Overvoltage, max.
AC, 5 x min. voltage,
DC, 10 x min. voltage (up to 300V)
CONTACTS
Contact Material:
Fine Silver
TIMING
Operate Time:
Release Time:
20 mS Max. @ Nominal Voltage.
20 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Across open contacts:
All Mutually Insulated
current carrying parts to
ground:
-45˚C to +65˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
500,000 Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear polycarbonate. (112-PGF Only)
7.05 oz. (200 g) approx.
OPERATING DATA: (All Types)
CONTACT RATINGS
AC
DC
30VDC
2A
2A
1500 V rms
TEMPERATURE
Rated Operation:
Approvals for
A112XAX & XBX Only.
UL Recognized
File No. E7104
LOAD
500 V rms
Min. Voltage: Selected from coil tables
Min. Current: Selected from coil tables
Series Coils: Available for connection in
series with loads up to 50
Amps for series 112, and
10 Amps for series 112-PGF.
120VAC 240VAC
2A
0.25A
2A
-
COIL SPECIFICATIONS
Measured @ 25˚C
TYPES A112XAX, 112XAXPGF
AC COILS, 50/60 HZ
Minimum Minimum Impedance
Voltage Milliamps
Ohms
1.0
1.4
1.6
2.0
2.5
3.5
4.3
5.0
6.0
8.5
12.0
13.5
16.
20
23
33
43
55
67
87
103
130
146
168
225
177
143
116
91.0
74.0
52.5
41.5
38.0
31.5
23.0
19.0
15.7
11.8
9.65
7.65
6.00
4.66
3.85
2.98
2.25
1.93
1.53
1.22
0.95
0.74
6
9
13
22
34
60
100
130
190
370
630
860
1,350
2,070
3,000
6,500
9,230
14,300
22,500
38,500
53,000
85,000
120,600
177,000
300,000
TYPES 112XBX, 112XBXPGF
DC COILS
Minimum Minimum Resistance
Voltage Milliamps
Ohms
0.08
0.10
0.12
0.15
0.19
0.25
0.30
0.39
0.49
0.62
0.78
0.95
1.30
1.60
2.00
2.50
3.20
3.90
4.80
6.40
8.00
9.70
11.7
16.0
21.0
145
117
95.0
73.0
60.0
43.0
33.0
31.0
26.0
18.8
15.5
12.8
9.70
7.90
6.30
4.90
3.80
3.15
2.43
1.84
1.58
1.25
1.00
0.84
0.61
0.55
0.84
1.26
2.10
3.10
5.80
9.00
12.5
19.0
33.0
50.0
74.0
129
197
312
504
840
1,220
1,990
3,450
5,050
7,700
11,700
19,000
34,000
AC COILS, 50/60 HZ
Minimum Minimum Impedance
Ohms
Voltage Milliamps
2.34
2.80
3.25
4.40
5.50
6.90
9.10
10.8
13.1
20.6
26.5
30.0
35.0
45.5
49.0
72.0
95.0
122
146
190
230
390
310
250
200
160
114
910
83.0
69.0
50.0
42.0
35.0
26.0
22.0
16.4
13.0
10.2
8.5
6.5
4.9
4.9
6
9
13
22
34
60
100
130
190
370
630
860
1,350
2,070
3,000
6,500
9,230
14,300
22,500
38,500
53,000
DC COILS
Minimum Minimum Resistance
Voltage Milliamps
Ohms
0.18
0.22
0.27
0.34
0.41
0.55
0.68
0.86
1.09
1.37
1.72
2.11
2.77
3.46
4.33
5.47
7.11
8.53
10.8
14.1
17.7
323
260
211
165
133
95.0
76.0
69.0
57.0
42.0
35.0
29.0
22.0
18.0
14.0
11.0
8.5
7.0
5.5
4.0
3.5
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
0.55
0.84
1.26
2.10
3.10
5.80
9.00
12.5
19.0
33.0
50.0
74.0
1219
197
312
504
840
1,220
1,990
3,450
5,050
PAGE 188
CLASS
3 AMP, LOW COIL POWER, 2 & 4 POLE PLUG-IN
67S
UL RECOGNIZED
FILE NO. E52197
TYPICAL CONTACT LIFE EXPECTANCY FOR
SWITCHING RESISTIVE LOADS @ 25˚C
Number of Operations
Load
Current
Load
Voltage
1.0A
0.5A
0.1A
1mA
CLASS 67 TYPICAL TIMING VALUES
Ultra
sensitive
5 X 105
5 X 106
5 X 107
5 X 107
-
28VDC/120VAC
28VDC/120VAC
6 VDC
6 VDC
POLES
DPDT
4PDT
OPERATE TIME
012
.014
RELEASE TIME .008
.008
Measured at Nominal Voltage @ 25˚C
Tolerances ± .010 Inches
DIMENSIONS
"A"
CONTACT
CONFIGURATION
"A"
DPDT
.978
(24.8)
4PDT
1.156
(29.4)
1.20 Max.
(30.3)
DIM.
.200 Max.
(5.1)
3-48UNC-2A Thd.
.094
(2.3)
.170
(4.3)
Elongated Hole .100 x .040 ( 2 x .1)
All Contact Terminals are .010 Thick
all coil terminals are .018 Thick.
SPECIFICATIONS CLASS 67S
COIL
Pickup voltage:
Dropout voltage:
Coil resistance:
Maximum coil dissipation:
Coil Temperature rise:
Maximum coil temperature:
CONTACTS
Contact material:
Contact resistance:
CAPACITANCE
Between contacts:
Contact to coil:
Coil to frame:
80% of nominal voltage or less.
10% of nominal or more.
± 10% measured @ 25˚C
2.2 watts @ 25˚C
30˚C per watt
105˚C
Silver, Gold overlay
50 milliohms max. initial
2 pf, typ.
2 pf, typ.
30 pf, typ.
DIELECTRIC STRENGTH
Contact to coil:
Across open contacts:
Coil to frame:
Contacts to frame:
Insulation resistance:
1500 V rms
500 V rms
1000 V rms
1500 V rms
1000 megohms @ 25˚C & 50% R.H.
TEMPERATURE
Operating:
Storage:
-55˚C to + 70˚C
-55˚C to +105˚C
MISCELLANEOUS
Enclosure Material:
Operating Position:
Mounting:
Weight:
Polycarbonate see thru plastic cover.
Any
Socket or 3-48 UNC stud
0.77 to 1.4 oz. (22 to 40 grams)
CLASS 67 - DC OPERATED - ULTRA SENSITIVE - PLUG-IN STYLE WITH 3-48 UNC STUD.
COIL Measured @ 25˚C
CROSS REFERENCE
CONTACT
TO
NOMINAL
PULL-IN CONFIGU- POTTER & BRUMFIELD
PULL-IN
PART NUMBERS CONTACT NOMINAL INPUT RESISTANCE
RATION
MILLIAMPS DC WATTS
RATING
MILLIAMPS DC
(OHMS)
STANDARD CONTACTS
W67SCSX-1
W67SCSX-2
W67SCSX-3
W67SCSX-6
W67SCSX-7
W67SCSX-8
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
3 AMPS
9.4 mADC
6.4 mADC
4.5 mADC
13.7 mADC
9.1 mADC
6.5 mADC
1000
2500
5000
1000
2500
5000
9.2 mADC
6.3 mADC
4.4 mADC
13.5 mADC
8.9 mADC
6.3 mADC
85mW
100mW
100mW
200mW
200mW
200mW
DPDT
DPDT
DPDT
4PDT
4PDT
4PDT
R10SE1(X or Y)2-J1.0K
R10SE1(X or Y)2-J2.5K
R10SE1(X or Y)2-J5.0K
R10SE1(X or Y)4-J1.0K
R10SE1(X or Y)4-J2.5K
R10SE1(X or Y)4-J5.0K
Part numbers shown also available thru Stocking Distribution.
SEE SECTION 10 FOR MATING SOCKETS
PAGE 189
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
SERIES
SENSITIVE PLUG-IN, 5 AMP, 1 - 3 POLES
392
The 392 series relay has been designed to operate at 125 Milliwatts
per pole. Because of the coil sensitivity, the contacts are rated at 5 Amps.
The Industry standard 8 pin octal plug is used with SPDT & DPDT contact
configurations, and the 11 pin plug is used with 3PDT contact configurations.
Silver contacts are standard on this 5 Amp Relay.
OUTLINE DIMENSIONS
Dimensions are shown in INCHES and (MILLIMETERS).
2.25
(57.1)
.40
(10.1)
1.37
(34.9)
.675
(17.1)
4
5
3
6
2
7
1
1.37
(34.9)
8
WIRING DIAGRAM
UL Recognized
File No. E13224
VIEWED FROM PIN END
CONTACT RATINGS
LOAD
30VDC 120VAC
Resistive
5A
5A
GENERAL SPECIFICATIONS 392
CONTACTS
Contact Material:
Silver
TIMING
Operate Time:
Release Time:
20 mS Max. @ Nominal Voltage.
15 mS Max. @ Nominal Voltage.
SPDT
DPDT
DIELECTRIC STRENGTH
Across open contacts:
500 V rms
All Mutually Insulated current
carrying parts to ground:
1500 V rms
Insulation Resistance:
1000 Megohms min. 500 V
TEMPERATURE
Rated Operation:
-45˚C to +70˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight;
Clear polycarbonate
3-1/2 oz. (99.2 g approx.).
COIL SPECIFICATIONS @ 25˚C
DPDT
Resistance
SPDT
392XBX
(Ohms)
392XAX
mA Volts mA Volts
1,000
2,500
5,000
10,000
11.1 15-44 15.8 21-44
7.0 23-68 10.0 32-68
5.0 32-97 7.0 45-97
3.5 45-139 5.0 64-139
Struthers-Dunn
ORDERING CODE
Typical Type No.
3PDT
392XCX
mA Volts
19.3 25-44
12.0 39-68
8.5 55-97
6.0 77-139
NOTES:
(1) Rates for continuous operation at 25˚C at voltages
within listed ranges.
(2) Must operate at min. currents listed. Specify current
when ordering
POWER CONSUMPTION: 125mW per pole @ currents
listed in the coil table.
3PDT
392 XBX 48P LM - 5.0M
Series
Series 392 enclosed plug-in, low
power consumtion coil.
Open Style (Consult Factory)
Contact Arrangements
XAX- SPDT
XBX - DPDT
XCX - 3PDT
Construction Style
Open Style: ( Consult Factory for
mounting styles, special wiring etc.).
Enclosed Plug-in - CODE 48P
Options
Indicator Lamp, (125 VDC coil only.see coil
specifications) - CODE L
Manual Actuator - CODE M
Operating Current (DC Only)
XAX: 11.1, 7.0, 5.0, 3.5 (Add M)
XBX: 15.8, 10.0, 7.0, 5.0 (Add M)
XCX: 19.3, 12.0, 8.5, 6.0 (Add M)
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 190
SERIES
SENSITIVE , 3-WAY TERMINALS, 5 AMP, 1 - 3 POLES
292
The 292 series relay has been designed to operate on 125 MILLIWATTS
per pole. Because of this coil sensitivity, the contacts are rated at 5 Amps. The
3-way terminal design provides additional versatility in wiring. The 1 to 3 Form
"C" contact configurations, are ideal for low current DC circuits that require up to
a 5 Amp outputs. Silver contacts are standard on this 5 Amp Relay.
R
UL Recognized
File No. E13224
OUTLINE DIMENSIONS
Dimensions shown are in INCHES and (MILLIMETERS)
2.90Max.
(73.8)
.187 x .020
(4.76 x 0.51)
QC Terminals Typical
2.50
(63.5)
WIRING DIAGRAM
Viewed from terminal end
1.53 Max.
.625 Typ.(38.8)
(15.8)
Top mount plate
& Stud
Manual Push Button
.218
Actuator
(5.56)
.156
(3.9)
1
4
2
5
3
6
7
8
9
A
ENCLOSED BRACKET MOUNT
The Body dimensions for the
Enclosed style Plug-in are the
same as the Bracket Mount style.
GENERAL SPECIFICATIONS
Silver
TIMING
Operate Time:
Release Time:
20 mS Max. @ Nominal Voltage.
15 mS Max. @ Nominal Voltage.
DIELECTRIC STRENGTH
Across open contacts:
500 V rms
All Mutually Insulated current
carrying parts to ground:
1500 V rms
Insulation Resistance:
1000 Megohms min. 500 V
TEMPERATURE
Rated Operation:
-45˚C to +70˚C
LIFE EXPECTANCY
Mechanical:
Electrical:
10 Million Operations no load
100,000 Operations @ Rated Load.
MISCELLANEOUS
Enclosure:
Weight:
Clear polycarbonate.
3 oz. (85.05 g) approx..
COIL SPECIFICATIONS @ 25˚C
1,000
2,500
5,000
10,000
DPDT
392XBX
mA Volts
11.1 15-44 15.8 21-44
7.0 23-68 10.0 32-68
5.0 32-97 7.0 45-97
3.5 45-139 5.0 64-139
3PDT
392XCX
mA Volts
19.3 25-44
12.0 39-68
8.5 55-97
6.0 77-139
NOTES:
(1) Rates for continuous operation at 25˚C at voltages
within listed ranges.
(2) Must operate at min. currents listed. Specify current
when ordering
POWER CONSUMPTION: 125mW per pole @ currents
listed in the coil table.
PAGE 191
1
4
2
5
3
6
7
8
9
7
8
9
B
A
B
DPDT
SPDT
292XBX
292XAX
B
.28 Typ.
(7.1)
1
4
2
5
3
6
7
8
9
B
A
3PDT
CONTACT RATINGS
LOAD
30VDC 120VAC 240VAC
Resistive
CONTACTS
Contact Material:
SPDT
392XACX
mA Volts
3
6
292XCX
Struthers-Dunn
Resistance
(Ohms)
2
5
A
1.90Max.
(48.4)
1.40Max.
(35.5)
ENCLOSED STYLE
Choice of 6-32 Stud or Tapped Core
with anti-rotation tab.
- OR 6-32 Stud with top mounting plate and
1/8" nominal length anti rotation tab.
1
4
ORDERING CODE
Typical Type No.
5A
5A
5A
292 XBX CS1
L - 10D
Series
Series 292 , 3-Way Terminals
125 Milliwatts per pole.
Contact Arrangements
XAX- SPDT (1 Form C)
XBX - DPDT (2 Form C)
XCX - 3PDT ( 2 Form C)
Construction Style
Open Style ( Consult Factory for
mounting styles, special wiring etc.)
Enclosed Plug-in - CODE C
Enclosed Bracket Mount - CODE C1
Enclosed with 6-32 Side tapped hole- CODE C2
Enclosed Bracket Mount - CODE C!
Enclosed with 6-32 side stud - CODE CS2
Options
Gold Diffused Contacts - CODE G
Indicator Lamp (125VDC Only) -CODE L
Manual Actuator - CODE M
Printed Circuit Terminals - CODE T
Coil Current (DC Milliamps Only).
XAX: 11.1, 7.0, 5.0, 3.5 (Add M)
XBX: 15.8, 10.0, 7.0, 5.0 (Add mA)
XCX: 19.3, 12.0, 8.5, 6.0 (Add mA)
SEE SECTION 10 FOR MATING SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N 10
10
SOCKETS
AND
ACCESS0RIES
Page 192
Magnecraft
Struthers-Dunn
SOCKET SELECTION GUIDE
FEATURES
Octal base, 8 or 11 Pin
socket. Panel or DIN rail
mount with Screw
Terminals & pressure
plates. Fits all standard
8 & 11 pin octal plugs.
70-464-1
8
250
314
70-465-1 11
Screw
UL
CSA
None
Yes
Yes
Yes
None
Yes
Yes
Yes
APPROVALS:
PAGE
CE NO.
195
Yes
Yes
Yes
No
16-1197
Yes
Yes
Yes
Solder
Solder
Chassis
Chassis
No
No
16-1197
16-1197
Yes
Yes
Yes
Yes
Yes
Yes
1, 2
4
P.C.
P.C.
P.C.
P.C.
No
No
16-1197
16-1197
Yes
Yes
Yes Yes
Yes Yes 198
235,
236,
388
1, 2
3
Screw
Panel or
DIN
Mount
No
16-1278
or
16-1239
Long Body
Yes
Yes
Yes
199
235, 236,
or 388,
1, 2
or 3
Solder, Chassis
3/16" Q.C. Chassis
P.C.
PC
P.C.
P.C.
No
No
No
No
16-722-2
16-722-2
16-722-2
16-722-2
Yes
Yes
Yes
Yes
Yes Yes
Yes Yes
Yes Yes
Yes Yes
200
4
Screw
78R
78
1, 2
4
8
14
78R
78
70-463-1
11
70-124-1
70-124-2
70-178-1
70-178-2
11
70-401-1
70-378-1
8
14
70-402-1
70-379-1
Class 388 & 283
Square Base 11 pin
Panel/DIN rail Mount,
with Screw Terminals.
Class 388 & 283
Square Base Socket for
blade style relays. Solder/
Plug-in, Quick connect or
Printed Circuit terminals.
P.C. Socket without
mounting ears 70-178-2
12
Panel or
Not
DIN
Required
Mount
CLIP
PART
NO.
16-1197
78
27390
HOLDDOWN
CLIP
INCLUDED
No
14
Class 76
Panel or DIN mount
Socket. Screw
Terminals with
pressure plates
3
MOUNTING
Panel or
DIN Mt.
Panel or
DIN Mt.
70-461-1
219 Style
Front connected wiring on
one level with Screw
Terminals. Mating relays
have Locking Clip that
mates with clip receiver
in socket. All Sockets are
supplied with insulated
backing plate. Fits 14 pin
219 style relays.
Screw
Screw
8
219 Style
Front connected wiring on
one level with Screw
Terminals. Mating relays
have Locking Clip that
mates with clip receiver
in socket. All Sockets are
supplied with insulated
backing plate. Fits 12 pin
219 style relays.
1, 2
1, 2
78R
70-459-1
Class 78
Panel Mount/DIN rail
mount with screw
Terminals, Chassis
mount with solder
terminals or P.C. mount
for direct solder to P.C.
board.
PAGE 193
USE
SOCKET NO. SOCKET
NO. OF TERMINAL
PART
WITH
OF
NO.
TYPES
PINS RELAY POLES
219
T219
246, 247
B255,
A311
349,
112-PGF
RSX1800
101-112
RRX164
33377
14
219
14 Pin
Versions
70-478-1
70-475-1
5
8
76EU
196
197
2 to 5
Pole
Screw
Panel
No
None
Yes
201
2 to 6
Pole
Screw
Panel
No
None
Yes
201
Panel or
Din rail
No
16-1264
1
2
Screw
Yes
Yes
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
202
Magnecraft
Struthers-Dunn
SOCKET SELECTION GUIDE
FEATURES
USE
NO. OF TERMINAL
SOCKET NO.
PART
OF SOCKET POLES
TYPES
NO.
PINS WITH
RELAY
Class 67
Chassis Mount Socket
has Solder terminals.
70-303-1
70-304-1
70-305-1
Printed Circuit Socket
70-306-1
pins are soldered
directly to the P.C.Board. 70-307-1
All sockets have relay
70-308-1
grounding strip that
70-309-1
connects to stud on
70-310-1
plug-in style relays.
10
10
16
16
22
22
28
28
67
2
2
4
4
6
6
8
8
Solder
P.C.
Solder
P.C.
Solder
P.C.
Solder
P.C.
Class 97
Chassis Mount
Socket with metal
mounting flange.
70-312
10
97
2
Solder
DIP
P.C. style 14 Pin
Socket. Fits 0.100
board spacing.
70-276
14
DIP
1 or 2
P.C.
MOUNTING
HOLDDOWN
CLIP
INCLUDED
Chassis
P.C.
Chassis
P.C.
Chassis
P.C.
Chassis
P.C.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
CLIP
PART
NO.
16-875-1
16-875-1
16-875-2
16-875-2
16-875-3
16-875-3
16-1120-8
16-1120-8
APPROVALS:
UL
CSA
CE
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
PAGE
NO.
203
204
Chassis
No
None
No
No
No
205
P.C.
No
None
No
No
No
205
No
No
No
ACCESSORIES
DIN rail conversion
kit for use on series
219 style sockets.
27390 (12 pin) and
33377 (14 pin)
CX-4092
DIN Rail
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 194
OCTAL
8 or 11 PIN SCREW TERMINAL SOCKETS
Compatible with European 35 mm DIN rail mounting.
Time saving snap in installation.
Non metallic spring mechanism eliminates mounting hardware.
Pressure clamp screw terminals hold wires mechanically secure.
Pressure clamp terminals provide excellent electrical connection.
Terminals accept up to two # 12 AWG wires.
One piece stamped metal interconnections. No welded or soldered
connections.
Fits all standard 8 and 11 pin relay plugs.
Can also be surface mounted with 2 screws.
DESIGNED FOR PANEL OR DIN MOUNT
RATED: 10 AMPS, 300V
MOLDED BASE, BREAK RESISTANT BLACK
THERMOPLASTIC WITH CLOSED BACK.
US
C
E70550
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
D
IN
R
A
IL
70-464-1 PANEL/DIN MOUNT SOCKET
Struthers-Dunn Equivalent Part Number 75224
IN
D
WIRING DIAGRAMS
R
SPDT, DPDT
IL
A
3PDT
1
11
2
70-465-1 PANEL/DIN MOUNT SOCKET
Struthers-Dunn Equivalent Part Number 75225
2
1
8
7
3
4
5
6
10
9
3
4
8
5
7
6
OUTLINE DIMENSIONS
.165 Dia. Mounting Hole
(2 Places)
2.33
Dimensions shown in Inches and (Millimeters)
.165 Dia. Mounting Hole
(2 Places)
(59.1)
1.60 Max.
(40.6)
2.05
(52.07)
2.020
(51.3)
.125 - .156
(3.17 - 3.96)
2.06
(52.3)
6-32 x .312 Combination
Head Screw & Pressure
Clamp (11 Places)
PART NUMBERS
70-464-1
70-465-1
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
STYLE
8 Pin Octal Socket, Panel/DIN
mount, Screw Terminals
11 Pin Octal Socket, Panel/DIN
mount,, Screw Terminals
WEIGHT
(GRAMS)
.580
(14.73)
.770
(19.56)
.970
(24.6)
P&B
.125 - .156
(3.17 - 3.96)
.150
(3.6)
.150
(3.6)
.610
(15.5)
1.29
(32.7)
.830
6-32 x .312 Combination
(21.08)
Head Screw & Pressure
Tolerances: ± .010
Clamp (11 Places)
± (0.25)
Unless otherwise shown.
IDEC
CROSS REFERENCE
CUSTOM CONNECTOR OMRON
ALLEN-BRADLEY GRAINGER
23.8
27E891 27E122 SR2P-06
OT08-PC
PF083A-E
700-HN125
5X852
75
27E892* 27E123 SR3P-06*
OT11-PC
PF113A-E*
700-HN126
6X156*
Part Numbers shown also available thru Stocking Distribution
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary.
* Track mountable but not compatible with Magnecraft mounting hole locations.
PAGE 195
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
SCREW TERMINAL SOCKETS - 1, 2 & 4 POLE
Compatible with European 35 mm DIN rail mounting.
Time saving snap in installation.
Non metallic spring mechanism eliminates mounting hardware.
Pressure clamp screw terminals hold wires mechanically secure.
Pressure clamp terminals provide excellent electrical connection.
Terminals accept up to two # 14 AWG wires for the 70-461-1,
and up to #12 AWG wires for the 70-459-1 sockets.
One piece stamped metal interconnections. No welded or soldered
connections.
Can also be surface mounted with 2 screws.
78
DESIGNED FOR PANEL OR DIN MOUNT
4 POLE: RATED 7 AMPS @ 300 VOLTS
1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS
US
C
E70550
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
D
IN
R
L
AI
WIRING DIAGRAMS
7
6
5
4
3
4
3
2
1
2
1
8
7
6
5
.240
(6.10)
Typ.
1.210
(30.7)
L
AI
R
OUTLINE DIMENSIONS
IN
8
70-459-1 PANEL/DIN MOUNT SOCKET
16-1197 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number 75227
13
14
Dimensions shown in Inches and (Millimeters)
SPDT, DPDT
D
4PDT
70-461-1 PANEL/DIN MOUNT SOCKET
16-1197 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number 75228
12 11 10
9
1.015
(25.78)
.315
(8.0)
1.18
(30)
.156
(4.0)
.160
(4.0)
.170
(4.3)
2.550
(64.8)
2.65
(67.3)
1.275
(32.4)
.197 ± .015
(5.0 ± 0.4)
1.325
(33.6)
.785
(19.9)
.895
(22.7)
1 or 2
4
1.00
(2.54)
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
WEIGHT
PART
NO. OF
SOCKET STYLE (GRAMS)
NUMBERS POLES
70-459-1
70-461-1
1.080
(27.4)
Screw Terminal
Screw terminal
49.8
42.8
.800
(20.3)
1.02
(26)
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
CROSS REFERENCE
P&B
27E895
27E894
P&B
IDEC
27E487* SH2B-05
27E166** SY4S-05
CUSTOM CONNECTOR
GT08-15
MT14-PC
OMRON
PTF08A-E
PYF14A-E
ALLEN-BRADLEY
GRAINGER
700-HN116
700-HN128
2A582
2A584
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down,
and socket internal wiring can vary.
* Panel mount
** Panel mount with grounding screw.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 196
CLASS
CHASSIS MOUNT SOCKETS - 1, 2 & 4 POLE
78
Sockets fit Class 78 style relays. The sockets are chassis
mounted and snap into panels up to .0625 (1.56) thick.
The 4 pole socket has an additional receptacle and solder
terminal for grounding 4 pole relays.
SOLDER TERMINALS
SNAPS INTO CHASSIS
4 POLE: RATED 5 AMPS @ 300 VOLTS
1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
US
C
E70550
70-378-1 SOLDER TERMINAL SOCKET
16-1197 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number 32884
70-401-1 SOLDER TERMINAL SOCKET
16-1197 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number 40051
OUTLINE DIMENSIONS
Dimensions shown in Inches and (Millimeters)
.850
(21.59)
1.015
(25.78)
1.150
(29.21)
SNAP FITS
INTO
CHASSIS
.0625 (1.56)
THICK
.075
(1.90)
.623
(15.82) Ground lug
.750
(19.05)
.105
(2.67)
.148 x .014
(3.75 x 0.355)
1 or 2
4
Solder Terminal
Solder Terminal
6.5
6.2
1.158
± .010
(29.41)
1.015
(25.8)
.075
(1.90)
.072 x .140 typ.
(1.83 x 3.56)
.440
(11.18)
.770
(19.56)
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
PART
WEIGHT
NO. OF
SOCKET STYLE (GRAMS)
NUMBERS POLES
70-401-1
70-378-1
.844
(21.44)
.860
(21.8)
R
PA ECO
NE M
L C ME
UT ND
OU ED
T
R
PA ECO
NE M
L C ME
UT ND
OU ED
T
.860
(21.84)
.180
(4.57) Typ.
CROSS REFERENCE
P&B
27E488
27E006
IDEC
SH2B-51
SY4S-51
CUSTOM CONNECTOR
GR108-SLD
MR14-SLD
OMRON ALLEN-BRADLEY
PT08
PY14
700-HN117
700-HN104
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, can vary.
PAGE 197
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
CLASS
PRINTEDP.C.
CIRCUIT
TERMINAL
SOCKETS
2 & 4 POLE
TERMINAL
SOCKETS
- 2 & 4- 1,
POLE
Sockets fit Class 78 style relays. The sockets are manufactured
with "floating" (loose) P.C. terminals that allow the terminals to
aline with holes in the circuit board without binding or bending
to get correct fit and alignment of terminals. The 4 pole socket
has an additional receptacle and solder terminal for grounding
4 pole relays.
PRINTED CIRCUIT TERMINALS
4 POLE: RATED 5 AMPS @ 300 VOLTS
1 & 2 POLE: RATED 10 AMPS @ 300 VOLTS
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
US
C
7878
E70550
70-402-1 SOLDER TERMINAL SOCKET
16-1197 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number 41463
70-379-1 SOLDER TERMINAL SOCKET
16-1197 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number 39830
OUTLINE DIMENSIONS
Dimensions shown in Inches and (Millimeters)
RECOMMENDED
PRINTED CIRCUIT LAYOUT
Viewed from component side
.350
(8.89)
.160
(4.06)
RECOMMENDED
PRINTED CIRCUIT LAYOUT
Viewed from component side
.850
(21.5)
.175
(4.45)
.410
(10.4)
.660
(16.7)
.185
.145
(3.68)
.262
(6.67)
.070 Dia.
(1.78)
14 Places
.417
(10.5)
.672
(17.07)
1.150
(29.21)
.598
(15.19) .024
(0.61)
.623
(15.82)
Ground
Lug
.525
(13.34)
.394
(10.0)
.175 x .010 typ.
(4.44 x .254)
.440
(11.18)
.086 Dia.
(2.18)
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
.060 Typ.
(1.52)
1.158
± .010
(29.41)
.620
(15.7)
.440
(11.18)
.600
(15.24)
.844
± .010
(21.44)
.672
(17.07)
.078 Typ.
(1.98)
.140 x .014
(3.55 x 0.355)
PART
NO. OF
SOCKET STYLE WEIGHT
NUMBERS POLES
(GRAMS)
70-402-1
70-379-1
1 or 2
4
Printed Circuit
Printed Circuit
5.8
5.9
CROSS REFERENCE
P&B
IDEC
27E489 SH2B-62
27E031 SY4S-61
CUSTOM CONNECTOR OMRON ALLEN-BRADLEY GRAINGER
GR108-PCB
MR14-PCB
PT08-0
PY14
700-HN118
700-HN105
2A583
-
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
Cross Reference reflects compatibility with relay foot prints. Shape, mounting and method of relay hold down can vary.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 198
CLASS
388 & 283
SCREW TERMINAL SOCKET - 1, 2 & 3 POLE
Compatible with European 35 mm DIN rail mounting.
Time saving snap in installation.
Non metallic spring mechanism eliminates mounting hardware.
Pressure clamp screw terminals hold wire mechanically secure.
Pressure clamp terminals provide excellent electrical connection.
Terminals accept up to two # 12 AWG wires. Break resistant
thermoplastic. One piece stamped metal interconnections. No
welded or soldered connections.
Can also be surface mounted with 2 screws.
FITS SQUARE BASE .187 (3/16")
BLADE STYLE RELAYS
RATED: 15 AMPS, 300 VAC
US
C
E70550
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
D
IN
R
A
IL
70-463-1 PANEL/DIN SOCKET
16-1278 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Number-75226
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
WIRING DIAGRAM
TOP VIEW
4
6
5
6-32 X .312 Combination Head
Screw and pressure clamp
1.03
(26.1)
.390
(9.9)
1.70
(43.1)
1.435
(36.4)
3
9
1
A
B
3.00
(76.2)
1.57
(39.9)
.150 Dia. (3.8)
(2 Places
2
8
7
.150
Retaining notch for
(3.81) hold down clip (2 Places)
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
PART NUMBERS
70-463-1 *
STYLE
11 Pin, Panel/DIN rail mount,
with Screw Terminals
WEIGHT
(GRAMS)
50.6
P&B
IDEC
27E893 SR3B-05
CROSS REFERENCE
CUSTOM CONNECTOR ALLEN-BRADLEY GRAINGER
ST11-PC
700-HN127
5X853
Part Numbers shown also available thru Stocking Distribution
* Order Part Number 16-1278 Hold Down Clip for relays with a case height of 1.90" using 3/16" (.187) terminals
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay hold down, and socket internal wiring can vary.
PAGE 199
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
SOLDER, Q.C. OR P.C. TERMINALS - 1, 2 & 3 POLE
FITS SQUARE BASE .187 (3/16")
BLADE STYLE RELAYS
RATED: 15 AMPS, 300 VAC
Sockets fit Class square base style relays with 3/16" (.187)
terminals. The quick connect, solder terminal and printed
circuit sockets have mounting tabs for mounting to panels
using two screws. The 70-178-2 Printed circuit socket has
no mounting tabs
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
US
C
388 & 283
E70550
RECOMMENDED CHASSIS CUTOUT
BOTTOM VIEW
BOTTOM VIEW
1.39
(35.4)
.391
(9.94)
16-722-2 Spring Clip Ordered separately.
Struthers-Dunn Equivalent Part Numbers
36580 = 70-124-1
36581 = 70-124-2
36579 = 70-178-1
1.68
1.27 (42.7)
(32.3)
OUTLINE DIMENSIONS
.257
(6.53)
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
FIG. "A"
.875
(22.2)
.437
(11.1)
.829
(21.0)
1.68
(42.7) .611
(15.5)
.287
(7.54)
Drill 11 .078 (1.98)
dia.holes for P.C.
terminals
.875
(22.2)
.205
(5.21)
Drill two .156 (3.96) dia.
holes for mounting Tabs.
.156 (3.96Dia. (2
holes)
.125
(3.17)
.500 typ
(12.7)
RECOMMENDED PRINTED
CIRCUIT BOARD LAYOUT
Note: Holes not required when
using Fig. "B" style socket
FIG. "B"
P.C. MOUNT
2.03
(51.6) 1.687
(42.85)
1.50
(38.1)
1.25
(31.75)
1.37
(34.8)
.218
(5.54)
.875
(22.2)
1.37
(34.8)
.165 Dia.(4.19) 2 holes
.540
(13.72)
Connectors are
Brass, Tin Plated.
.297
(7.5)
.130 Solder Terminal or
.187 (3/16" Q.C. Terminal
1.50
(38.1)
.156
(3.96)
.297
(7.5)
.156
(3.96)
Printed Circuit
mounting
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
Printed Circuit mounting
with mounting Tabs
PART NUMBERS
70-124-1
70-124-2
70-178-1
70-178-2
FIG
FIG "A"
FIG "A"
FIG "A"
FIG "B"
STYLE
.130 SOLDER TERMINAL
3/16" (.187) QUICK CONNECT
PRINTED CIRCUIT, WITH TABS
PRINTED CIRCUIT, NO TABS
WEIGHT
(GRAMS)
12.1
12.1
9.4
9.4
CROSS REFERENCE
CUSTOM CONNECTOR ALLEN-BRADLEY GRAINGER
27E043 SR3B-51
CM11-SLD
5X854
27E067
700-HN107
CM11-QDC
27E304
CM11-PCB
CM11-PCB-1S
P&B
IDEC
Part Numbers shown also available thru Stocking Distribution
Order Part Number 16-722-2 Hold Down Clip (Struthers-Dunn Equivalent 37067) for relays with a case height of 1.90 (48.2)
Cross Reference reflects compatibility with relay foot prints. Shape, mounting and method of relay hold down can vary.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 200
SERIES
SCREW TERMINAL SOCKETS
219
12 and 14 PIN PANEL MOUNT SOCKETS
FIT ALL 219 STYLE RELAYS WITH
12 OR 14 PIN PLUGS.
RATED: 10 AMPS, 600 VAC
These Industrial style sockets offer front-connected wiring
on one level with screw terminals accessible and numbered
for ease in installation, wiring and checkout. Sockets are
polarized. The mating relay has a locking clip that snaps into
the socket, eliminating any need for external holding
devices. All sockets are supplied with an insulating
paper back plate for greater dielectric strength.
US
C
E13224
E70550
Recognized to Canadian safety
requirements under the Component
Recognition Program of Underwriters
Laboratories Inc.
UL LISTED WHEN USED
WITH SERIES 219 RELAYS
27390 - 12 PIN PANEL MOUNT SOCKET
33377 - 14 PIN PANEL MOUNT SOCKET
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
12 PIN SOCKET
2.65
(67.3)
1.687
(42.84)
3.10
(78.74)
.484
(12.29)
1.687
(42.84)
.484
(12.29)
2.18
(55.3)
.687
(17.4)
2.18
(55.3)
.687
(17.4)
6-32 screws
12 Places
14 PIN SOCKET
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
6-32 screws
14 Places
.173 (4.39)
mounting Holes
2 Places
.173 (4.39)
mounting Holes
2 Places
.780
(19.8)
.780
(19.8)
INSULATING PAPER BACK PLATE
INSULATING PAPER BACK PLATE
Struthers-Dunn
PART NUMBERS
27390
33377
STYLE
12 PIN SOCKET
14 PIN SOCKET
WEIGHT CROSS REFERENCE
(GRAMS) CUSTOM CONNECTOR
SD12-PC
102
SD14-PC
120
Part Number Shown also Available thru Stocking distribution
Notes: Insulating Back Plate Included with Socket
When Sockets are mounted end to end, the distance between adjacent mounting holes should be 1" minimum.
PAGE 201
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
CLASS
SCREW TERMINAL SOCKETS - 1 & 2 POLE
Compatible with European 35 mm DIN rail mounting.
Time saving snap in installation.
Pressure clamp screw terminals hold wires mechanically secure.
Pressure clamp terminals provide excellent electrical connection.
Terminals accept up to two # 14 AWG wires.
One piece stamped metal interconnections. No welded or soldered
connections.
Fits all standard Class 76 relays
Can also be surface mounted with 1 screw.
76
PANEL/DIN RAIL MOUNT.
DIELECTRIC STRENGTH 1500 V rms, 1 MINUTE.
RATED: 15 AMPS, 250 VAC.
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
70-475-1 PANEL/DIN SOCKET
16-1321 Spring Clip Ordered separately.
SOCKET PART NO. (SPDT) 70-478-1
.615
(15.6)
.150 Dia.
(3.81)
SOCKET PART NO. (DPDT) 70-475-1
.615
(15.6)
.153
(3.89)
1.25
(31.7)
.150 Dia.
(3.81)
1.02
(26)
.75
(19)
2.765
(70.23)
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
PART NUMBERS
STYLE
STANDARD FOOT PRINT FOR STYLE 76EURCPCXSPDT, Panel/DIN mount, Screw Terminal
70-478-1
DPDT, Panel/DIN mount, Screw terminal
70-475-1
WEIGHT CROSS REFERENCE
(GRAMS)
P&B
IDEC
19.3
19.5
27E1038
27E1039
RP 78 604
RP 78 605
Part Numbers Shown also Available thru Stocking distribution
Cross Reference reflects compatibility with relay foot prints. Shape, mounting, method of relay
hold down, and socket internal wiring can vary.
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 202
CLASS
67
SOLDER TERMINAL SOCKETS - 2 TO 8 POLE
CHASSIS MOUNT SOCKETS
RATED: 10 AMPS MAX.
Sockets fit Class 67 style relays with solder/plug-in
terminals. All sockets have an grounding strip that connects
with the mounting screw to the chassis. Contact material
used is spring brass, tin plated. The body material is
phenolic. Dielectric strength: 1000 V rms. Insulation
Resistance 10 9 megohms
.210
(5.33)
70-303-1
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
.210
(5.33)
.350
(8.89)
2 POLE
.978
(24.8)
70-307-1
16-875-1 Spring hold down Clip included
.350
(8.89)
6 POLE
1.390
(35.3)
16-875-3 Spring hold down Clip included
.210
(5.33)
70-305-1
4 POLE
1.184
(30.1)
.210
(5.33)
70-309-1
8 POLE
16-875-2 Spring hold down Clip included
.350
(8.89)
1.596
(40.54)
16-1120-8 Spring hold down Clip included
CHASSIS CUTOUT
for panel mounting.
.281
(7.14)
CHASSIS CUTOUT
DIMENSION "B"
"B"
.281 ± .015
(7.14) ± 0.38
.656 ± .015
(16.66) ± 0.38
.354
(8.99)
.140
(3.5)
CHASSIS MOUNT
SPDT
DPDT 4PDT 6PDT 8PDT
.343 .562 .781 1.00
(8.71) (14.3) (19.84) (25.4)
.109 DIA. (2.77)
.090 X .045
(2.3 X 1.14)
Elongated Holes
.210
(5.33)
.750
(19.05)
.350
(8.89)
USE 3-48 SCREW &
NUT FOR MOUNTING
SOCKET
GROUND STRIP FOR
3-48 UN-2A STUD
PART
NUMBERS
70-303-1
70-305-1
70-307-1
70-309-1
NO. OF
POLES
SOCKET STYLE
2
4
6
8
Solder Terminal
Solder Terminal
Solder Terminal
Solder Terminal
WEIGHT CROSS REFERENCE
(GRAMS) POTTER-BRUMFIELD
4.3
5.5
6.9
8.5
27E125
27E126
27E127
27E211
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
RELAY HOLD DOWN CLIP IS INCLUDED WITH ALL SOCKETS
PAGE 203
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
.350
(8.89)
CLASS
P.C. TERMINAL SOCKETS - 2 TO 8 POLE
Sockets fit Class 67 style relays with solder/plug-in
terminals. All sockets have an grounding strip that connects
with the mounting screw to the chassis. Contact material
used is spring brass, tin plated. The body material is
phenolic. Dielectric strength: 1000 V rms. Insulation
Resistance 10 9 megohms
67
PRINTED CIRCUIT SOCKETS
RATED: 10 AMPS MAX.
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
.180
(457)
70-304-1
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
.350
(8.89)
2 POLE
.978
(24.8)
16-875-1 Spring hold down Clip included
.180
(457)
70-306-1
4 POLE
.350
(8.89)
1.184 .
(30.1)
16-875-2 Spring hold down Clip included
.180
(4.57)
70-308-1
6 POLE
.350
(18.9)
1.390
(35.3)
16-875-3 Spring hold down Clip included
.180
(457)
70-310-1
8 POLE
.350
(8.89)
1.596
(40.54)
16-1120-8 Spring hold down Clip included
SUGGESTED P.C. BOARD LAYOUT
TOP VIEW (Component side of board)
.500
(12.70)
.750
(19.05)
8 Pole
.100
(2.54)
GRID
typical
6 Pole
4 Pole
2 Pole
.500
(12.7)
.056 + .004 Dia.
- .000 Holes
(1.42 + .10)
- .00
USE 3-48 SCREW &
NUT FOR MOUNTING
SOCKET
.450
(11.43)
.150
(3.81)
GROUND STRIP FOR
3-48 UN-2A STUD
NOTE:
WHEN INSTALLING SOCKET(S) INTO A PRINTED CIRCUIT
BOARD, USE PLUG-IN STYLE RELAYS FOR MAXIMUM
TERMINAL CONTACT WITH MATING SOCKETS. PLUG-IN
STYLE RELAYS HAVE A GROUNDING STUD AND ARE
RECOMMENDED FOR USE WITH ALL SOCKET STYLES.
.100
(2.54)
PART
NUMBERS
NO. OF
POLES
70-304-1
70-306-1
70-308-1
70-310-1
2
4
6
8
SOCKET STYLE WEIGHT
(GRAMS)
P.C. Terminal
P.C. Terminal
P.C. Terminal
P.C. Terminal
4.3
5.5
6.9
8.5
CROSS REFERENCE
POTTER-BRUMFIELD
27E128
27E129
27E130
27E254
PART NUMBERS SHOWN ALSO AVAILABLE THRU STOCKING DISTRIBUTION.
RELAY HOLD DOWN CLIP IS INCLUDED WITH ALL SOCKETS
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
PAGE 204
CLASS
SOLDER TERMINAL SOCKET
97
CHASSIS MOUNT SOCKET
ACCEPTS .250 CONTACT TERMINALS
AND .110 COIL TERMINALS.
Recommended
RATED: 25 AMPS
Chassis Layout
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
3
2.126
+ .004
1.65
(41.9)
.175 ± .005
(4.44) ± .127)
2 Holes
5
4
6
1.57
(39.8)
1
2
7
9
10
8
2.12
(53.8)
1.65
(41.9)
2.50
(63.5)
70-312
.988
(25.09)
1.57
(39.8)
.098 Dia.
(2.48)
(2 Places)
.118 Dia.
(2.99)
(8 Places)
Part Number
STYLE
WEIGHT
(GRAMS)
70-312
10 Contact socket, Chassis
Mounted, Solder Terminal
48
Part Number Shown also Available thru Stocking distribution
CLASS
P.C. TERMINAL, DUAL INLINE SOCKET
DIP
DIP (DUAL INLINE PACKAGE)
PHOSPHOR BRONZE CONTACTS, TIN PLATED
THERMOPLASTIC POLYESTER BODY
0.100 GRID SPACING
OUTLINE DIMENSIONS
DIMENSIONS ARE SHOWN IN INCHES AND (MILLIMETERS).
Tolerances: ± .010
± (0.25)
Unless otherwise shown.
70-276
Equal Spacing at .100 Centers
Suggested Layout
.396
(10.06)
Part Number
STYLE
70-276
14 Pin DIP Socket, 0.100
Pin Spacingl
WEIGHT
(GRAMS)
1
Part Number Shown also Available thru Stocking distribution
PAGE 205
.696
(17.7)
.200
(5.08)
.035 Dia,
(.889)
0.100 Grid Pattern
.015
(.38)
.130
(3.30)
.025 x .008 Terminals
(.63 x .20)
WEBSITE: www.magnecraft.com EMAIL:[email protected] FAX ON DEMAND 1-800/891-2957, DOCUMENT 100
S E C T I O N 11
11
UTILIZATION
CATEGORIES
Page 206
UTILIZATION CATEGORIES FOR
LOW VOLTAGE SWITCHGEAR AND CONTROL GEAR
Nature of
Category
Current
AC
AC-1
AC-2
AC-3
AC-4
AC-5a
AC-5b
AC-6a
AC-6b
AC-7a
AC-7b
AC-8a
AC-8b
947-4
947-5
Control of A.C. electromagnetic loads.
Connecting and disconnecting under no-load conditions,
Switching of resistive loads, including moderate overloads.
Switching of mixed resistive and inductive loads, including
moderate overloads.
Switching of motor loads or other highly inductive loads.
947-3
A
B
Protection of circuits, with no rated short time withstand current
Protection of circuits, with a rated short time withstand current
947-2
DC-1
DC-3
Non-inductive or slightly inductive Loads, resistance furnaces
Shunt-motors, Starting, plugging 1), inching 2), dynamic breaking
of motors.
Series-motors, Starting, plugging 1), inching 2), dynamic breaking
of motors.
Switching of incandescent lamps.
Control of resistive loads and solid state loads with isolation by
optocouplers.
Control of DC electromagnets
Control of DC electromagnetic loads having economy resistors
in circuit.
Connecting and disconnecting under no-load conditions
Switching of resistive loads, including moderate overloads.
Switching of mixed resistive and inductive loads, including
moderate overloads (e.g. shunt motors)
Switching of highly inductive loads (e.g. series motors).
AC-13
AC-14
AC-15
AC-20
AC-21
AC-22
AC-23
DC
Non-inductive or slightly inductive Loads, resistance furnaces
Slip-ring motors: Starting, switching off.
Squirrel-cage motors: Starting, switching off motors during
running.
Squirrel-cage motors: Starting, plugging 1), inching 2)
Switching of electric discharge lamp control
Switching of incandescent lamps.
Switching of transformers
Switching of capacitor banks.
Slightly inductive loads in household appliances and similar
applications.
Motor-loads for household applications.
Hermetic refrigerant compressor motor control with manual
resetting of overload releases.
Hermetic refrigerant compressor motor control with automatic
resetting of overload releases.
Relevant I.E.C.
Product Standard
Control of resistive loads and solid state loads with isolation
by optocouplers.
Control of solid state loads with transformer isolation.
Control of small electromagnetic loads.
AC-12
AC
and
DC
Typical Applications
DC-5
DC-6
DC-12
DC-13
DC-14
DC-20
DC-21
DC-22
DC-23
947-4
947-5
947-3
1) By plugging is understood stopping or reversing the motor rapidly by reversing motor primary connections
while the motor is running.
2) By inching (jogging) is understood energizing a motor once or repeatedly for short periods to obtain small
movements of the drive mechanism
PAGE 207
WEBSITE: www.magnecraft.com - EMAIL:[email protected] - FAX ON DEMAND 1-800/891-2957 - DOCUMENT 100
CUSTOMER SERVICE STAFF & SUPPORT
Tel: 843/393-5778 Fax: 843/393-4123
Pricing
Delivery
Cross-Reference
Return Authorization
Order Entry
Bill Moody
Shelby Hall
Natalie Campbell
Beverly Streett
Gaye Register
Tel: 843/393-5421
Product Quality
Application
Engineering
Assistance
Jim Berg
Fax: 843/393-4123
Q.C. Manager
Les Wynne
MIL Spec.
Bill Brady
Solid State & Time Delay Relays
Tom Mahaffey
Industrial Relays
Tel: 847/441-2531
Gene Piskorz
Chuck Johnson
Tel: 843/393-5421
Invoices
Customer Service Manager
Sr. Customer Service Coord.
Customer Service Coordinator
Customer Service Coordinator
Customer Service Coordinator
Marjorie Bacote
Fax: 847/4412522
Industrial Relays
P.C. Relays
Fax: 843/393-7843
Credit Manager
Magnecraft/Struthers-Dunn
is an innovator and provider of quality relay products with
a hands on commitment to staying close to customers worldwide.
Our Goal
is to deliver defect-free products on time, all the time.
We Pledge
ourselves to achieve these goals in a manner which assures profitability and
resources to support growth.
We Encourage
an atmosphere where diligence and hard work can exist in harmony with
warmth, laughter, continuing education and personal development. We will conduct business
in a way that encourages integrity in every employee, supplier and customer relationship.
Magnecraft
Struthers-Dunn
LIMITED WARRANTY
MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. warrants its product to be free of defects in workmanship and materials for a period of one year from date of delivery to the
purchaser buying direct from MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. or authorized Distributor.
This warranty includes, but is not limited to those products manufactured to specifications supplied to us by the purchaser. Any defects appearing more than one year from the date
of delivery to the purchaser, shall be deemed to be due to ordinary wear and tear.
MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. assumes no risk or liability for the suitability or unsuitability or results of the use of its products, used in combinations with any
electrical or electronic components, circuits, systems, assemblies, or any other material or substances, or environments. The purchaser's right under this warranty shall consist
solely of requiring MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to repair, or in MAGNECRAFT'S/ MSD's sole discretion, replace, free of charge, F.O.B., factory, any
defective items received at its factory within said year, as determined by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to be defective.
All products to be returned to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. for evaluation under this warranty, shall first receive a Return Authorization Number and
Shipping Label from our Sales Department. All products shall be shipped to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. prepaid. All products received at MAGNECRAFT
ELECTRIC COMPANY/ MSD, Inc. without written authorization and return label, shall be returned at the sender's expense.
The failure to give or the giving of any advice or recommendations by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. shall not constitute any warranty by, or impose any
liability upon MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. The sole and exclusive remedy of the purchaser and the exclusive liability of MAGNECRAFT ELECTRIC
COMPANY/MSD, Inc. are outlined and stated above, AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY AS TO
MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS, OR ANY OTHER MATTER.
In no event shall MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. be liable for consequential or special damages, or for the delay in the performance of this warranty.
MAGNECRAFT & STRUTHERS DUNN
700 ORANGE STREET
DARLINGTON, SC. 29532-3739
TEL.: (843) 393-5778
FAX: (843) 393-4123
WEBSITE: www.magnecraft.com
EMAIL: [email protected]
EUROPE
MAGNECRAFT & STRUTHERS-DUNN
OFFICE MUNICH
FORSTENRIEDER
ALLEE 227
..
D 81476 MUNCHEN / GERMANY
TEL.: 4989 75080310
FAX: 4989 7558344
PRINTED IN U.S.A.
981015K
Magnecraft
Struthers-Dunn
LIMITED WARRANTY
MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. warrants its product to be free of defects in workmanship and materials for a period of one year from date of delivery to the
purchaser buying direct from MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. or authorized Distributor.
This warranty includes, but is not limited to those products manufactured to specifications supplied to us by the purchaser. Any defects appearing more than one year from the date
of delivery to the purchaser, shall be deemed to be due to ordinary wear and tear.
MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. assumes no risk or liability for the suitability or unsuitability or results of the use of its products, used in combinations with any
electrical or electronic components, circuits, systems, assemblies, or any other material or substances, or environments. The purchaser's right under this warranty shall consist
solely of requiring MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to repair, or in MAGNECRAFT'S/ MSD's sole discretion, replace, free of charge, F.O.B., factory, any
defective items received at its factory within said year, as determined by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. to be defective.
All products to be returned to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. for evaluation under this warranty, shall first receive a Return Authorization Number and
Shipping Label from our Sales Department. All products shall be shipped to MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. prepaid. All products received at MAGNECRAFT
ELECTRIC COMPANY/ MSD, Inc. without written authorization and return label, shall be returned at the sender's expense.
The failure to give or the giving of any advice or recommendations by MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. shall not constitute any warranty by, or impose any
liability upon MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. The sole and exclusive remedy of the purchaser and the exclusive liability of MAGNECRAFT ELECTRIC
COMPANY/MSD, Inc. are outlined and stated above, AND IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY AS TO
MERCHANTABILITY, FITNESS FOR PURPOSE SOLD, DESCRIPTION, QUALITY, PRODUCTIVENESS, OR ANY OTHER MATTER.
In no event shall MAGNECRAFT ELECTRIC COMPANY/ MSD, Inc. be liable for consequential or special damages, or for the delay in the performance of this warranty.
U.S.A.
MAGNECRAFT & STRUTHERS DUNN
700 ORANGE STREET
DARLINGTON, SC. 29532-3739
TEL.: (843) 393-5778
FAX: (843) 393-4123
WEBSITE: www.magnecraft.com
EMAIL: [email protected]
EUROPE
MAGNECRAFT & STRUTHERS-DUNN
OFFICE MUNICH
FORSTENRIEDER
ALLEE 227
..
D 81476 MUNCHEN / GERMANY
TEL.: 4989 75080310
FAX: 4989 7559344
PRINTED IN U.S.A.
981015K