ETC WEDPN16M64V-XBX

White Electronic Designs
WEDPN16M64V-XBX
16Mx64 Synchronous DRAM
FEATURES
GENERAL DESCRIPTION
! High Frequency = 100, 125MHz
The 128MByte (1Gb) SDRAM is a high-speed CMOS, dynamic random-access, memory using 4 chips containing
268,435,456 bits. Each chip is internally configured as a
quad-bank DRAM with a synchronous interface. Each of the
chip’s 67,108,864-bit banks is organized as 8,192 rows by
512 columns by 16 bits.
! Package:
• 219 Plastic Ball Grid Array (PBGA), 25 x 25mm
! Single 3.3V ±0.3V power supply
! Fully Synchronous; all signals registered on positive edge
of system clock cycle
Read and write accesses to the SDRAM are burst oriented;
accesses start at a selected location and continue for a programmed number of locations in a programmedsequence.
Accesses begin with the registration of an ACTIVE command, which is then followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be
accessed (BA0, BA1 select the bank; A0-12 select the row).
The address bits registered coincident with the READ or
WRITE command are used to select the starting column location for the burst access.
! Internal pipelined operation; column address can be
changed every clock cycle
! Internal banks for hiding row access/precharge
! Programmable Burst length 1,2,4,8 or full page
! 8192 refresh cycles
! Commercial, Industrial and Military Temperature Ranges
! Organized as 16M x 64
• User configurable as 2 x 16M x 32 and 4 x 16M x 16
The SDRAM provides for programmable READ or WRITE burst
lengths of 1, 2, 4 or 8 locations, or the full page, with a
burst terminate option. An AUTO PRECHARGE function may
be enabled to provide a self-timed row precharge that is
initiated at the end of the burst sequence.
! Weight: WEDPN16M64V-XBX - 2.5 grams typical
BENEFITS
! 41% SPACE SAVINGS
The 1Gb SDRAM uses an internal pipelined architecture to
achieve high-speed operation. This architecture is compatible with the 2 n rule of prefetch architectures, but it also
allows the column address to be changed on every clock
cycle to achieve a high-speed, fully random access.
Precharging one bank while accessing one of the other three
banks will hide the precharge cycles and provide seamless, high-speed, random-access operation.
! Reduced part count
! Reduced trace lengths for lower parasitic capacitance
! Suitable for hi-reliability applications
! Laminate interposer for optimum TCE match
! Upgradeable to 32M x 64 density (contact factory for
information)
* This data sheet describes a product that is subject to change without notice.
November 2003 Rev. 6
1
White Electronic Designs Corporation • (602) 437-1520 • www.whiteedc.com
White Electronic Designs
FIG. 1 PIN CONFIGURATION
TOP VIEW
NOTE: DNU = Do Not Use; to be left unconnected for future upgrades.
NC = Not Connected Internally.
White Electronic Designs Corporation • Phoenix AZ • (602) 437-1520
2
WEDPN16M64V-XBX
WEDPN16M64V-XBX
White Electronic Designs
FIG. 2 FUNCTIONAL BLOCK DIAGRAM
WE0
RAS 0
CAS 0
WE RAS CAS
A0-12
DQ0
BA0-1
¥
A0-12
BA0-1
CLK0
CKE0
CS0
DQML0
DQMH0
CLK
CKE
CS
DQML
DQMH
U0
DQ0
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
DQ15
DQ15
WE1
RAS 1
CAS 1
WE RAS CAS
A0-12
DQ0
BA0-1
¥
CLK1
CKE1
CS1
DQML1
DQMH1
CLK
CKE
CS
DQML
DQMH
U1
DQ16
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
DQ15
DQ31
WE2
RAS 2
CAS 2
WE RAS CAS
A0-12
DQ0
BA0-1
¥
CLK2
CKE2
CS2
DQML2
DQMH2
CLK
CKE
CS
DQML
DQMH
U2
DQ32
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
DQ15
DQ47
WE3
RAS 3
CAS 3
WE RAS CAS
A0-12
DQ0
BA0-1
¥
CLK3
CKE3
CS3
DQML3
DQMH3
CLK
CKE
CS
DQML
DQMH
U3
DQ48
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
¥
DQ15
DQ63
WEDPN16M64BD.eps
3
White Electronic Designs Corporation • (602) 437-1520 • www.whiteedc.com
White Electronic Designs
REGISTER DEFINITION
MODE REGISTER
The 1Gb SDRAM is designed to operate in 3.3V, low-power
memory systems. An auto refresh mode is provided, along
with a power-saving, power-down mode.
The Mode Register is used to define the specific mode of
operation of the SDRAM. This definition includes the selec-tion
of a burst length, a burst type, a CAS latency, an operating mode
and a write burst mode, as shown in Figure 3. The Mode Register
is programmed via the LOAD MODE REGISTER command and will
retain the stored information until it is programmed again or the
device loses power.
All inputs and outputs are LVTTL compatible. SDRAMs offer
substantial advances in DRAM operating performance, including the ability to synchronously burst data at a high data
rate with automatic column-address generation, the ability
to interleave between internal banks in order to hide
precharge time and the capability to randomly change column addresses on each clock cycle during a burst access.
Mode register bits M0-M2 specify the burst length, M3 specifies
the type of burst (sequential or interleaved), M4-M6 specify the
CAS latency, M7 and M8 specify the operating mode, M9
specifies the WRITE burst mode, and M10 and M11 are reserved
for future use. Address A12 (M12) is undefined but should be
driven LOW during loading of the mode register.
FUNCTIONAL DESCRIPTION
Read and write accesses to the SDRAM are burst oriented; accesses start at a selected location and continue for a programmed
number of locations in a programmed sequence. Accesses
begin with the registration of an ACTIVE command which is then
followed by a READ or WRITE command. The address bits registered coincident with the ACTIVE command are used to select the bank and row to be accessed (BA0 and BA1 select the
bank, A0-12 select the row). The address bits (A0-8) registered
coincident with the READ or WRITE command are used to select
the starting column location for the burst access.
The Mode Register must be loaded when all banks are idle, and
the controller must wait the specified time before initiating the
subsequent operation. Violating either of these requirements
will result in unspecified operation.
BURST LENGTH
Read and write accesses to the SDRAM are burst oriented, with
the burst length being programmable, as shown in Figure 3. The
burst length determines the maximum number of column locations that can be accessed for a given READ or WRITE command.
Burst lengths of 1, 2, 4 or 8 locations are available for both the
sequential and the interleaved burst types, and a full-page burst
is available for the sequential type. The full-page burst is used
in conjunction with the BURST TERMINATE command to generate
arbitrary burst lengths.
Prior to normal operation, the SDRAM must be initialized. The
following sections provide detailed information covering device initialization, register definition, command descriptions and
device operation.
INITIALIZATION
SDRAMs must be powered up and initialized in a predefined manner. Operational procedures other than those
specified may result in undefined operation. Once power
is applied to VDD and VDDQ (simultaneously) and the
clock is stable (stable clock is defined as a signal cycling
within timing constraints specified for the clock pin), the
SDRAM requires a 100µs delay prior to issuing any command other than a COMMAND INHIBIT or a NOP. Starting
at some point during this 100µs period and continuing at
least through the end of this period, COMMAND INHIBIT
or NOP commands should be applied.
Reserved states should not be used, as unknown operation or
incompatibility with future versions may result.
When a READ or WRITE command is issued, a block of columns
equal to the burst length is effectively selected. All accesses for
that burst take place within this block, meaning that the burst will
wrap within the block if a boundary is reached. The block is
uniquely selected by A1-8 when the burst length is set to two; by
A2-8 when the burst length is set to four; and by A3-8 when the
burst length is set to eight. The remaining (least significant) address
bit(s) is (are) used to select the starting location within the block.
Full-page bursts wrap within the page if the boundary is reached.
Once the 100µs delay has been satisfied with at least one COMMAND INHIBIT or NOP command having been applied, a
PRECHARGE command should be applied. All banks must be
precharged, thereby placing the device in the all banks idle state.
BURST TYPE
Accesses within a given burst may be programmed to be either
sequential or interleaved; this is referred to as the burst type and
is selected via bit M3.
Once in the idle state, two AUTO REFRESH cycles must be
performed. After the AUTO REFRESH cycles are complete, the
SDRAM is ready for Mode Register programming. Because the
Mode Register will power up in an unknown state, it should be
loaded prior to applying any operational command.
White Electronic Designs Corporation • Phoenix AZ • (602) 437-1520
WEDPN16M64V-XBX
The ordering of accesses within a burst is determined by the
burst length, the burst type and the starting column address, as
shown in Table 1.
4
White Electronic Designs
FIG. 3 MODE REGISTER DEFINITION
TABLE 1 - BURST DEFINITION
Burst
Length
A12
A11 A10 A9
A8
A6
A7
A5
A3
A4
A2
A1 A0
Address Bus
2
Mode Register (Mx)
Unused Reserved* WB Op Mode
CAS Latency
BT
Burst Length
4
*Should program
M12, M11, M10 = 0, 0, 0
to ensure compatibility
with future devices.
Burst Length
M2 M1 M0
M3 = 0
M3 = 1
0
0 0
1
1
0
0 1
2
2
0
1 0
4
4
0
1 1
8
8
1
0 0
Reserved
Reserved
1
0 1
Reserved
Reserved
1
1 0
Reserved
Reserved
1
1 1
Full Page
Reserved
8
Burst Type
M3
0
Sequential
1
Interleaved
M6 M5 M4
0 0
Reserved
0
0 1
Reserved
0
1 0
2
0
1 1
3
1
0 0
Reserved
1
0 1
Reserved
1
1 0
Reserved
1
1 1
Reserved
M8
M7
M6-M0
Operating Mode
0
0
Defined
Standard Operation
-
-
-
Write Burst Mode
0
Programmed Burst Length
1
Single Location Access
Full
Page
(y)
CAS Latency
0
M9
WEDPN16M64V-XBX
Starting Column
Address
A0
0
1
A1 A0
0
0
0
1
1
0
1
1
A2 A1 A0
0
0
0
0
0
1
0
1
0
0
1
1
1
0
0
1
0
1
1
1
0
1
1
1
n = A0-9/8/7
(location 0-y)
Order of Accesses Within a Burst
Type = Sequential
Type = Interleaved
0-1
1-0
0-1
1-0
0-1-2-3
1-2-3-0
2-3-0-1
3-0-1-2
0-1-2-3
1-0-3-2
2-3-0-1
3-2-1-0
0-1-2-3-4-5-6-7
1-2-3-4-5-6-7-0
2-3-4-5-6-7-0-1
3-4-5-6-7-0-1-2
4-5-6-7-0-1-2-3
5-6-7-0-1-2-3-4
6-7-0-1-2-3-4-5
7-0-1-2-3-4-5-6
Cn, Cn + 1, Cn + 2
Cn + 3, Cn + 4...
…Cn - 1,
Cn…
0-1-2-3-4-5-6-7
1-0-3-2-5-4-7-6
2-3-0-1-6-7-4-5
3-2-1-0-7-6-5-4
4-5-6-7-0-1-2-3
5-4-7-6-1-0-3-2
6-7-4-5-2-3-0-1
7-6-5-4-3-2-1-0
Not Supported
NOTES:
1. For full-page accesses: y = 512.
2. For a burst length of two, A1-8 select the block-of-two burst; A0 selects the
starting column within the block.
3. For a burst length of four, A2-8 select the block-of-four burst; A0-1 select the
starting column within the block.
4. For a burst length of eight, A3-8 select the block-of-eight burst; A0-2 select the
starting column within the block.
5. For a full-page burst, the full row is selected and A0-8 select the starting
column.
6. Whenever a boundary of the block is reached within a given sequence above,
the following access wraps within the block.
7. For a burst length of one, A0-8 select the unique column to be accessed, and
Mode Register bit M3 is ignored.
All other states reserved
WEDPN16M72MRD.eps
5
White Electronic Designs Corporation • (602) 437-1520 • www.whiteedc.com
White Electronic Designs
WEDPN16M64V-XBX
FIG. 4 CAS LATENCY
CAS LATENCY
M8 to zero; the other combinations of values for M7 and
M8 are reserved for future use and/or test modes. The programmed burst length applies to both READ and WRITE
bursts.
The CAS latency is the delay, in clock cycles, between the
registration of a READ command and the availability of the
first piece of output data. The latency can be set to two or
three clocks.
Test modes and reserved states should not be used because unknown operation or incompatibility with future
versions may result.
If a READ command is registered at clock edge n, and the
latency is m clocks, the data will be available by clock edge
n+m. The I/Os will start driving as a result of the clock edge
one cycle earlier (n + m - 1), and provided that the relevant access times are met, the data will be valid by clock
edge n + m. For example, assuming that the clock cycle
time is such that all relevant access times are met, if a READ
command is registered at T0 and the latency is programmed
to two clocks, the I/Os will start driving after T1 and the
data will be valid by T2. Table 2 below indicates the operating frequencies at which each CAS latency setting can be
used.
TABLE 2 - CAS LATENCY
SPEED
ALLOWABLE OPERATING
FREQUENCY (MHZ)
CAS
CAS
LATENCY = 2
LATENCY = 3
-100
- 75
- 100
-125
- 100
- 125
Reserved states should not be used as unknown operation or incompatibility with future versions may result.
WRITE BURST MODE
OPERATING MODE
When M9 = 0, the burst length programmed via M0-M2
applies to both READ and WRITE bursts; when M9 = 1, the
programmed burst length applies to READ bursts, but
write accesses are single-location (nonburst) accesses.
The normal operating mode is selected by setting M7and
White Electronic Designs Corporation • Phoenix AZ • (602) 437-1520
6
WEDPN16M64V-XBX
White Electronic Designs
TRUTH TABLE - COMMANDS AND DQM OPERATION (NOTE 1)
NAME (FUNCTION)
CS
RAS
CAS
WE
DQM
ADDR
I/Os
COMMAND INHIBIT (NOP)
H
X
X
X
X
X
X
NO OPERATION (NOP)
L
H
H
H
X
X
X
ACTIVE (Select bank and activate row) ( 3)
L
L
H
H
X
Bank/Row
X
READ (Select bank and column, and start READ burst) (4)
L
H
L
H
L/H 8
Bank/Col
X
WRITE (Select bank and column, and start WRITE burst) (4)
L
H
L
L
L/H 8
Bank/Col
Valid
BURST TERMINATE
L
H
H
L
X
X
Active
PRECHARGE (Deactivate row in bank or banks) ( 5)
L
L
H
L
X
Code
X
AUTO REFRESH or SELF REFRESH (Enter self refresh mode) (6, 7)
L
L
L
H
X
X
X
LOAD MODE REGISTER (2)
L
L
L
L
X
Op-Code
X
Write Enable/Output Enable (8)
–
–
–
–
L
–
Active
Write Inhibit/Output High-Z (8)
–
–
–
–
H
–
High-Z
NOTES:
1. CKE is HIGH for all commands shown except SELF REFRESH.
2. A0-11 define the op-code written to the Mode Register.
3. A0-12 provide row address, and BA0, BA1 determine which bank is made active.
4. A0-8 provide column address; A10 HIGH enables the auto precharge feature (nonpersistent), while A10 LOW disables the auto precharge feature; BA0, BA1
determine which bank is being read from or written to.
5. A10 LOW: BA0, BA1 determine the bank being precharged. A10 HIGH: All banks precharged and BA0, BA1 are “Don’t Care.”
6. This command is AUTO REFRESH if CKE is HIGH; SELF REFRESH if CKE is LOW.
7. Internal refresh counter controls row addressing; all inputs and I/Os are “Don’t Care” except for CKE.
8. Activates or deactivates the I/Os during WRITEs (zero-clock delay) and READs (two-clock delay).
COMMANDS
banks are idle, and a subsequent executable command
cannot be issued until tMRD is met.
The Truth Table provides a quick reference of available commands. This is followed by a written description of each
command. Three additional Truth Tables appear following
the Operation section; these tables provide current state/
next state information.
ACTIVE
The ACTIVE command is used to open (or activate) a row
in a particular bank for a subsequent access. The value on
the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A12 selects the row. This row remains
active (or open) for accesses until a PRECHARGE command
is issued to that bank. A PRECHARGE command must be
issued before opening a different row in the same bank.
COMMAND INHIBIT
The COMMAND INHIBIT function prevents new commands
from being executed by the SDRAM, regardless of whether
the CLK signal is enabled. The SDRAM is effectively deselected. Operations already in progress are not affected.
READ
NO OPERATION (NOP)
The READ command is used to initiate a burst read access
to an active row. The value on the BA0, BA1 inputs selects
the bank, and the address provided on inputs A0-8 selects the starting column location. The value on input A10
determines whether or not AUTO PRECHARGE is used. If
AUTO PRECHARGE is selected, the row being accessed will
be precharged at the end of the READ burst; if AUTO
PRECHARGE is not selected, the row will remain open for
subsequent accesses. Read data appears on the I/Os subject to the logic level on the DQM inputs two clocks earlier.
If a given DQM signal was registered HIGH, the corresponding I/Os will be High-Z two clocks later; if the DQM signal
was registered LOW, the I/Os will provide valid data.
The NO OPERATION (NOP) command is used to perform a
NOP to an SDRAM which is selected (CS is LOW). This prevents unwanted commands from being registered during
idle or wait states. Operations already in progress are not
affected.
LOAD MODE REGISTER
The Mode Register is loaded via inputs A0-11. See Mode
Register heading in the Register Definition section. The LOAD
MODE REGISTER command can only be issued when all
7
White Electronic Designs Corporation • (602) 437-1520 • www.whiteedc.com
White Electronic Designs
WRITE
WEDPN16M64V-XBX
fixed-length or full-page bursts. The most recently registered
READ or WRITE command prior to the BURST TERMINATE
command will be truncated.
The WRITE command is used to initiate a burst write access
to an active row. The value on the BA0, BA1 inputs selects
the bank, and the address provided on inputs A0-8 selects the starting column location. The value on input A10
determines whether or not AUTO PRECHARGE is used. If
AUTO PRECHARGE is selected, the row being accessed
will be precharged at the end of the WRITE burst; if AUTO
PRECHARGE is not selected, the row will remain open for
AUTO REFRESH
AUTO REFRESH is used during normal operation of the
SDRAM and is analagous to CAS-BEFORE-RAS (CBR) REFRESH
in conventional DRAMs. This command is nonpersistent, so
it must be issued each time a refresh is required.
The addressing is generated by the internal refresh controller. This makes the address bits “Don’t Care” during an AUTO
REFRESH command. Each 256Mb SDRAM requires 8,192
AUTO REFRESH cycles every refresh period (tREF). Providing a distributed AUTO REFRESH command will meet the
refresh requirement and ensure that each row is refreshed.
Alternatively, 8,192 AUTO REFRESH commands can be
issued in a burst at the minimum cycle rate (tRC), once every refresh period (tREF).
PRECHARGE
The PRECHARGE command is used to deactivate the open
row in a particular bank or the open row in all banks. The
bank(s) will be available for a subsequent row access a
specified time (tRP) after the PRECHARGE command is issued. Input A10 determines whether one or all banks are
to be precharged, and in the case where only one bank is
to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are treated as “Don’t Care.” Once a bank
has been precharged, it is in the idle state and must be
activated prior to any READ or WRITE commands being issued to that bank.
SELF REFRESH*
The SELF REFRESH command can be used to retain data in
the SDRAM, even if the rest of the system is powered down.
When in the self refresh mode, the SDRAM retains data without external clocking. The SELF REFRESH command is initiated like an AUTO REFRESH command except CKE is disabled (LOW). Once the SELF REFRESH command is registered, all the inputs to the SDRAM become “Don’t Care,”
with the exception of CKE, which must remain LOW.
AUTO PRECHARGE
AUTO PRECHARGE is a feature which performs the same
individual-bank PRECHARGE function described above,
without requiring an explicit command. This is accomplished
by using A10 to enable AUTO PRECHARGE in conjunction
with a specific READ or WRITE command. A precharge of
the bank/row that is addressed with the READ or WRITE command is automatically performed upon completion of the
READ or WRITE burst, except in the full-page burst mode,
where AUTO PRECHARGE does not apply. AUTO
PRECHARGE is nonpersistent in that it is either enabled or
disabled for each individual READ or WRITE command.
Once self refresh mode is engaged, the SDRAM provides
its own internal clocking, causing it to perform its own AUTO
REFRESH cycles. The SDRAM must remain in self refresh
mode for a minimum period equal to tRAS and may remain
in self refresh mode for an indefinite period beyond that.
The procedure for exiting self refresh requires a sequence
of commands. First, CLK must be stable (stable clock is
defined as a signal cycling within timing constraints specified for the clock pin) prior to CKE going back HIGH. Once
CKE is HIGH, the SDRAM must have NOP commands issued (a minimum of two clocks) for tXSR, because time is
required for the completion of any internal refresh in
progress.
AUTO PRECHARGE ensures that the precharge is initiated at
the earliest valid stage within a burst. The user must not issue another command to the same bank until the precharge
time (tRP) is completed. This is determined as if an explicit
PRECHARGE command was issued at the earliest possible
time.
BURST TERMINATE
Upon exiting the self refresh mode, AUTO REFRESH commands must be issued as both SELF REFRESH and AUTO
REFRESH utilize the row refresh counter.
The BURST TERMINATE command is used to truncate either
* Self refresh available in commercial and industrial temperatures only.
White Electronic Designs Corporation • Phoenix AZ • (602) 437-1520
8
WEDPN16M64V-XBX
White Electronic Designs
ABSOLUTE MAXIMUM RATINGS
Parameter
Voltage on VDD, VDDQ Supply relative to Vss
Voltage on NC or I/O pins relative to Vss
Operating Temperature TA (Mil)
Operating Temperature TA (Ind)
Storage Temperature, Plastic
-1 to 4.6
-1 to 4.6
-55 to +125
-40 to +85
-55 to +150
CAPACITANCE (NOTE 2)
Parameter
Unit
V
V
°C
°C
°C
Symbol
Max
Unit
Input Capacitance: CLK
CI1
10
pF
Addresses, BA0-1 Input Capacitance
CA
30
pF
Input Capacitance: All other input-only pins
CI2
10
pF
Input/Output Capacitance: I/Os
CIO
12
pF
BGA THERMAL RESISTANCE
NOTE:
Stress greater than those listed under "Absolute Maximum Ratings" may cause
permanent damage to the device. This is a stress rating only and functional
operation of the device at these or any other conditions greater than those
indicated in the operational sections of this specification is not implied. Exposure
to absolute maximum rating conditions for extended periods may affect
reliability.
Description
Symbol
Max
Unit
Junction to Ambient (No Airflow)
Theta JA
14.2
C/W
Notes
1
Junction to Ball
Theta JB
9.6
C/W
1
Junction to Case (Top)
Theta JC
4.8
C/W
1
Note:
Refer to AN #0001 at www.whiteedc.com in the application notes section for
modeling conditions.
DC ELECTRICAL CHARACTERISTICS AND OPERATING CONDITIONS (NOTES 1, 6)
(VCC = +3.3V ±0.3V; TA = -55°C TO +125°C)
Parameter/Condition
Symbol
Units
Supply Voltage
VCC
Min
3
Input High Voltage: Logic 1; All inputs (21)
VIH
2
VCC + 0.3
Input Low Voltage: Logic 0; All inputs (21)
VIL
-0.3
0.8
V
II
-4
4
µA
InputLeakageCurrent:Anyinput0V-VIN-VCC(Allotherpinsnotundertest=0V)
Input Leakage Address Current (All other pins not under test = 0V)
Max
3.6
V
V
II
-20
20
µA
Output Leakage Current: I/Os are disabled; 0V - VOUT - VCC
IOZ
-5
5
µA
Output Levels:
Output High Voltage (IOUT = -4mA)
VOH
2.4
–
V
Output Low Voltage (IOUT = 4mA)
VOL
–
0.4
V
ICC SPECIFICATIONS AND CONDITIONS (NOTES 1,6,11,13)
(VCC = +3.3V ±0.3V; TA = -55°C TO +125°C)
Symbol
Max
Units
Operating Current: Active Mode;
Burst = 2; Read or Write; tRC = t RC (min); CAS latency = 3 (3, 18, 19)
Parameter/Condition
I CC1
700
mA
Standby Current: Active Mode; CKE = HIGH; CS = HIGH;
All banks active after tRCD met; No accesses in progress (3, 12, 19)
I CC3
240
mA
Operating Current: Burst Mode; Continuous burst;
Read or Write; All banks active; CAS latency = 3 (3, 18, 19)
I CC4
700
mA
Self Refresh Current: CKE - 0.2V (Commercial Temperature: 0°C to + 70°C) (27)
I CC7
16
mA
Self Refresh Current: CKE - 0.2V (Industrial Temperature: (-40°C to + 85°C) (27)
I CC7
20
mA
9
White Electronic Designs Corporation • (602) 437-1520 • www.whiteedc.com
WEDPN16M64V-XBX
White Electronic Designs
ELECTRICAL CHARACTERISTICS AND RECOMMENDED AC OPERATING CHARACTERISTICS
(NOTES 5, 6, 8, 9, 11)
Parameter
Symbol
-100
Min
Access time from CLK (pos. edge)
-125
Max
Min
Unit
Max
CL = 3
tAC
7
6
ns
CL = 2
tAC
7
6
ns
Address hold time
tAH
1
1
ns
Address setup time
tAS
2
2
ns
CLK high-level width
tCH
3
3
ns
CLK low-level width
tCL
3
3
ns
CL = 3
tCK
10
8
ns
CL = 2
tCK
13
10
ns
CKE hold time
tCKH
1
1
ns
CKE setup time
tCKS
2
2
ns
CS, RAS, CAS, WE, DQM hold time
tCMH
1
1
ns
CS, RAS, CAS, WE, DQM setup time
tCMS
2
2
ns
Data-in hold time
tDH
1
1
ns
Data-in setup time
tDS
2
2
Clock cycle time (22)
Data-out high-impedance time
CL = 3 (10)
tHZ
CL = 2 (10)
tHZ
7
7
ns
6
ns
6
ns
Data-out low-impedance time
tLZ
1
1
ns
Data-out hold time (load)
tOH
3
3
ns
Data-out hold time (no load) (26)
tOHN
1.8
1.8
ACTIVE to PRECHARGE command
tRAS
50
ACTIVE to ACTIVE command period
tRC
70
68
ACTIVE to READ or WRITE delay
tRCD
20
20
Refresh period (8,192 rows) – Commercial, Industrial
tREF
120,000
50
64
ns
ns
ns
64
ms
16
ms
Refresh period (8,192 rows) – Military
tREF
AUTO REFRESH period
tRFC
70
70
ns
PRECHARGE command period
tRP
20
20
ns
ACTIVE bank A to ACTIVE bank B command
tRRD
20
20
tT
0.3
Transition time (7)
WRITE recovery time
(23)
(24)
Exit SELF REFRESH to ACTIVE command
White Electronic Designs Corporation • Phoenix AZ • (602) 437-1520
16
ns
120,000
1 CLK + 7ns
tWR
tXSR
10
1.2
0.3
1 CLK + 7ns
ns
1.2
ns
—
15
15
ns
80
80
ns
WEDPN16M64V-XBX
White Electronic Designs
AC FUNCTIONAL CHARACTERISTICS (NOTES 5,6,7,8,9,11)
Parameter/Condition
Symbol
-100
-125
Units
READ/WRITE command to READ/WRITE command (17)
tCCD
1
1
tCK
CKE to clock disable or power-down entry mode (14)
tCKED
1
1
tCK
CKE to clock enable or power-down exit setup mode (14)
tPED
1
1
tCK
DQM to input data delay (17)
tDQD
0
0
tCK
DQM to data mask during WRITEs
tDQM
0
0
tCK
DQM to data high-impedance during READs
tDQZ
2
2
tCK
WRITE command to input data delay (17)
tDWD
0
0
tCK
Data-in to ACTIVE command (15)
tDAL
4
5
tCK
Data-in to PRECHARGE command (16)
tDPL
2
2
tCK
Last data-in to burst STOP command (17)
tBDL
1
1
tCK
Last data-in to new READ/WRITE command (17)
tCDL
1
1
tCK
Last data-in to PRECHARGE command (16)
tRDL
2
2
tCK
LOAD MODE REGISTER command to ACTIVE or REFRESH command (25)
tMRD
2
2
tCK
CL = 3
tROH
3
3
tCK
CL = 2
tROH
2
—
tCK
Data-out to high-impedance from PRECHARGE command (17)
NOTES:
14. Timing actually specified by tCKS ; clock(s) specified as a reference only at
minimum cycle rate.
15. Timing actually specified by tWR plus tRP; clock(s) specified as a reference
only at minimum cycle rate.
1. All voltages referenced to V SS.
2. This parameter is not tested but guaranteed by design. f = 1 MHz, TA = 25°C.
3. I DD is dependent on output loading and cycle rates. Specified values are
obtained with minimum cycle time and the outputs open.
4. Enables on-chip refresh and address counters.
5. The minimum specifications are used only to indicate cycle time at which
proper operation over the full temperature range is ensured.
6. An initial pause of 100µs is required after power-up, followed by two AUTO
REFRESH commands, before proper device operation is ensured. (VCC must
be powered up simultaneously.) The two AUTO REFRESH command wakeups should be repeated any time the tREF refresh requirement is exceeded.
7. AC characteristics assume tT = 1ns.
8. In addition to meeting the transition rate specification, the clock and CKE
must transit between V IH and V IL (or between VIL and VIH ) in a monotonic
manner.
9. Outputs measured at 1.5V with equivalent load:
16. Timing actually specified by tWR.
17. Required clocks are specified by JEDEC functionality and are not dependent
on any timing parameter.
18. The ICC current will decrease as the CAS latency is reduced. This is due to the
fact that the maximum cycle rate is slower as the CAS latency is reduced.
19. Address transitions average one transition every two clocks.
20. CLK must be toggled a minimum of two times during this period.
21. VIH overshoot: V IH (MAX) = VCC + 2V for a pulse width - 3ns, and the pulse
width cannot be greater than one third of the cycle rate. VIL undershoot: VIL
(MIN) = -2V for a pulse width - 3ns.
22. The clock frequency must remain constant (stable clock is defined as a signal
cycling within timing constraints specified for the clock pin) during access or
precharge states (READ, WRITE, including tWR, and PRECHARGE commands).
CKE may be used to reduce the data rate.
23. Auto precharge mode only. The precharge timing budget (tRP) begins 7.5ns/
7ns after the first clock delay, after the last WRITE is executed.
24. Precharge mode only.
25. JEDEC and PC100 specify three clocks.
26. Parameter guaranteed by design.
27. Self refresh available in commercial and industrial temperatures only.
10. tHZ defines the time at which the output achieves the open circuit condition;
it is not a reference to V OH or VOL . The last valid data element will meet t OH
before going High-Z.
11. AC timing and I DD tests have VIL = 0V and VIH = 3V, with timing referenced
to 1.5V crossover point.
12. Other input signals are allowed to transition no more than once every two
clocks and are otherwise at valid VIH or V IL levels.
13. ICC specifications are tested after the device is properly initialized.
11
White Electronic Designs Corporation • (602) 437-1520 • www.whiteedc.com
WEDPN16M64V-XBX
White Electronic Designs
PACKAGE DIMENSION: 219 PLASTIC BALL GRID ARRAY (PBGA)
BOTTOM VIEW
25.10 (0.988) sq. MAX
19.05 (0.750) NOM
1.27 (0.050) NOM
BOTTOM VIEW
1.27 (0.050) NOM
219 x 0.762
(0.030) NOM
19.05 (0.750) NOM
0.61 (0.024) NOM
2.03 (0.080)
MAX
ALL LINEAR DIMENSIONS ARE MILLIMETERS AND PARENTHETICALLY IN INCHES
ORDERING INFORMATION
WED P N 16M 64 V - XXX B X
DEVICE GRADE:
M = Military
-55°C to +125°C
I = Industrial
-40°C to +85°C
C = Commercial
0°C to +70°C
PACKAGE:
B = 219 Plastic Ball Grid Array (PBGA)
FREQUENCY (MHz)
100 = 100MHz
125 = 125MHz
3.3V Power Supply
CONFIGURATION, 16M x 64
SDRAM
PLASTIC
WHITE ELECTRONIC DESIGNS CORP.
White Electronic Designs Corporation • Phoenix AZ • (602) 437-1520
12