ETC WT260-S280

W 260 Photoelectric switches
Photoelectric
proximity switches,
BGS
Photoelectric
proximity switches,
energetic
Photoelectric
reflex switches
W 260: Standard photoelectric
switch series for a broad range
of applications
■
universal voltage 12 . . . 24 V DC
and 24 . . . 240 V AC with potential-free relay contact (SPDT) or,
alternatively, adjustable time
delay.
A variety of features make these
sensors particularly operatorfriendly. These include visible red
transmitted light used as an alignment aid, or the simple and
flexible connection system,
glass/stainless steel fibre-optic
cables for harsh operating condi-
Through-beam
photoelectric
switches
Photoelectric
switches with
fibre-optic cable
Proximity mode
Photoelectric
switches with
fibre-optic cable
Through-beam mode
T
tions in confined environments.
All of these benefits open up
The W 260 series with its
applications far beyond hand-
impressive scanning ranges and
ling/warehousing systems, the
features has been specially
packaging industry and wood
designed for a wide variety of
working. All device variants
different applications. The
have been granted UL and CSA
sensors, through-beam photo-
approval.
electric switches, energetic
photoelectric proximity switches,
One last highlight: the W 260
and photoelectric reflex switches
complies with EN 50081-1
with background suppression are
(interference radiation). This
contained in robust plastic
makes it the perfect sensor
housings. Handling is simple and
solution for door and gate control
user-friendly. Two supply voltages systems in underground garages
are available:
■
low voltage 10 . . . 30 V DC with
PNP or NPN transistor switching
output and test input and
246
SENSICK CATALOGUE
and for use in residential blocks
or hotels.
W 260
n WS/WE 260
through-beam photoelectric switches and
WT 260 photoelectric proximity
switches used for
monitoring contours
in palletisation
systems to ensure
that no problems are
encountered during
packaging.
b A WT 260 photoelectric proximity switch
controlling a commissioning system used
in the wood-working industry.
v CE conformity to EN 50081-1 and,
therefore, the right choice for residential
and commercial applications: the WL 260
photoelectric reflex switch used to monitor
the closing edges in automatic door and
gate systems.
v WS/WE 260 through-beam photoelectric
switches used for detecting the outline of
vehicle bodies on assembly lines in the
automotive industry.
SENSICK CATALOGUE
247
WT 260 Photoelectric proximity switches, background suppression, infrared light -- DC
Dimensional drawing
Scanning distance
0 . . . 380 mm
■
77.5
5
3
4
19.5
6
4
5.5
■
2
max.
21
■
1
14
■
Reliable detection of dark objects
even against light backgrounds
Scanning distance continuously
adjustable
Terminal chamber or M 12 plug,
4-pin or 5-pin
Test input
Pre-failure signalling output
39.5
■
63
1.5
25
Photoelectric proximity switches
19.5
50
61
5.5
Adjustments possible
1
2
3
WT 260-P 260
WT 260-P 460
WT 260-P 560
4
5
5
6
SENS
L
D
MODE
7
5
8
7
8
1
9
4
9
2
Standard direction of material being scanned
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm optionally at
bottom or rear; or M 12 equipment plug bottom
LED signal strength indicator, red
Through hole l 5.2 mm on both sides for M 5 hex nut
Scanning distance adjustment
Light-/dark-switching
(L = light-switching, D = dark-switching)
Terminals
3
Connection types
C V
Accessories
Cable receptacles M 12
Mounting brackets*
* included with delivery
page
496
510
WT 260-P 260
WT 260-P 460
WT 260-P 560
Terminals
4-pin, M 12
5-pin, M 12
1
2
SENSICK CATALOGUE
M
1
2
4
Q
4
3
VMA
3
5
248
L+
TE
5
1
3
4
L+
M
Q
1
2
4
3
2
TE
5
1
3
4
5
2
L+
M
Q
VMA
TE
WT 260
Technical data
WT 260-
Scanning distance
Max.: 0 . . . 380 mm, adjustable 1)
Min.: 75 . . .160 mm, adjustable 1)
Adjustable, potentiometer 270°
Light source 2), light type
Light spot diameter
Aperture angle sender
LED, infrared light
Approx. 17 mm at 300 mm
Approx. 1.5°
Supply voltage Vs
Ripple 4)
Current consumption 5)
10 . . . 30 V DC 3)
≤ 5 VSS
≤ 35 mA
Switching outputs
Output current IA max.
Light receiver, switching mode
Response time 6)
Max. switching frequency 7)
Pre-failure signalling output VMA 8)
PNP, open collector: Q
100 mA
Light-/dark-switching by sliding switch
≤ 2 ms
250/s
100 mA, static
Test input ”TE” sender off
PNP: TE to + VS
Connection types
Terminal chamber
Plug M 12, 4-pin
Plug M 12, 5-pin
VDE protection class 9)
Circuit protection 10)
Enclosure rating
V
Ambient temperature TA
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
Scanning distance
P 260 P 460 P 560
A, B, C, D
IP 66
Weight
Material
1) Object with 90 % remission
(based on standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) Limit values
4) Must be within VS tolerances
5) Without load
6) With resistive load
7) With light/dark ratio 1:1
8) Operating reserve < 50 %
9) Reference voltage 50 V DC
10) A = Vs connections reverse-polarity
protected
B = Inputs/outputs reverse-polarity
protected
C = Interference suppression
D = Outputs overcurrent and shortcircuit protected
11) Black = 16 % remission
Grey = 18 % remission
White = 90 % remission
Order information
Type
Part no.
WT 260-P 260
6 009 471
Scanning distance
20
1 A
95 140
50
1 B
WT 260-P 460
WT 260-P 560
6%/90%
300
1
85 150
2 A
2 B
15
25
3 A
1 011 540
1 011 541
340
75
160
18%/90%
0 (mm)
1
2
3
A
B
380
100
200
300
Scanning range on black 11)/background white
Scanning range on grey 11)/background white
Scanning range on white 11)/background white
Scanning distance control set to MIN
Scanning distance control set to MAX
10
400
% of scanning distance
3 B 0
2
5
90%/90%
3
0
(mm) 150
200
250
300
350
400
SENSICK CATALOGUE
249
WT 260 Photoelectric proximity switches, background suppression, infrared light -- UC
Dimensional drawing
Scanning distance
0 . . . 380 mm
77.5
3
4
6
5.5
5.5
■
2
5
19.5
■
1
14
■
Reliable detection of dark objects
even against light backgrounds
Scanning distance continuously
adjustable
Terminal chamber
Universal current supply,
relay output, SPST, timer optional
39.5
■
63
1.5
25
Photoelectric proximity switches
4
19.5
Adjustments possible
1
2
3
4
WT 260-R 260
WT 260-S 260
5
MODE
1 1
5
6
1 2
7
8
1 O.S.D.
2 OFF.D.
3 ON.D.
4 NORMAL
2
4
1 0
1 2 3 4
1
OUTPUT TIMER
3
TIMER
9
MODE
L. ON D. ON
MODE
8
8
L.ON D.ON 0.1 5(SEC)
SENS.
7
SENS.
7
3
1
4
2
9
1 0
1 1
1 2
C V
Connection type
WT 260-S 260
WT 260-R 260
5.5
50
61
5.5
Standard direction of material being scanned
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread for cable
diameters from 6 to 10 mm optionally at
bottom or rear
LED signal strength indicator, red
Through hole l 5.2 mm on both sides for
M 5 hex nut
Scanning distance adjustment
Light/dark rotary switch
(L.ON = light-switching, D.ON = dark-switching)
Time range control
Terminals
Red LED status indicator; switching output
active
Time delay selector switch
O.S.D. = One Shot
OFF.D. = OFF delay
ON.D. = ON delay
Normal = No delay
Time delay
t = 0.1 – 5 s
Light
beam
Timer mode
NORMAL
1 23 4
O.S.D.
T
1 23 4
Accessories
Mounting brackets*
* included with delivery
page
510
Terminals
1 23 4
1
L1
2
N
3
4
250
SENSICK CATALOGUE
OFF.D.
ON.D.
1 23 4
T
T
T
T
T
T
T
T
T
T
T
T
T
Setting mode: X light-switching
x dark-switching
Uninterrupted
Interrupted
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
WT 260
Technical data
WT 260-
Scanning distance
Max.: 0 . . . 380 mm, adjustable 1)
Min.: 75 . . .160 mm, adjustable 1)
Adjustable, potentiometer 270°
Light source 2), light type
Light spot diameter
Angle of dispersion, sender
LED, infrared light
Approx. 17 mm at 300 mm
Approx. 1.5°
Supply voltage Vs3)
Power consumption
12 . . . 240 V DC
24 . . . 240 V AC
≤ 5 VA
Switching outputs
Switching current IA max. 4)
Light receiver, switching mode
Response time
Max. switching frequency 5)
Time delay
Switch position:
«1 O.S.D.»
«2 OFF.D.»
«3 ON.D.»
«4 Normal»
Delay
Relay, SPST, electrically isolated
3 A/240 V AC; 3 A/30 V DC
Light-/dark-switching by rotary switch
≤ 20 ms
25/s
With LED display: switching output active
«One shot»
OFF delay
ON delay
No delay
Adjustable, 0.1. . . 5 s; potentiom. 270°
Connection type
Terminal chamber
VDE protection class 6)
Circuit protection 7)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) ± 10 %
4) Provide suitable spark suppression for
inductive or capacitive loads
5) With light/dark ratio 1:1
Scanning distance
S 260 R 260
A, C
IP 66
6) Reference voltage 250 V UC
7) A = Vs connections reverse-polarity
protected
C = Interference suppression
8) Black = 16 % remission
Grey = 18 % remission
White = 90 % remission
Order information
Type
Part no.
WT 260-S 260
6 009 473
Scanning distance
20
1 A
95 140
50
1 B
WT 260-R 260
6%/90%
300
6 009 472
1
85 150
2 A
2 B
15
25
3 A
340
75
160
18%/90%
0 (mm)
1
2
3
A
B
380
100
200
300
Scanning range on black 8)/background white
Scanning range on grey 8)/background white
Scanning range on white 8)/background white
Scanning distance control set to MIN
Scanning distance control set to MAX
10
400
% of scanning distance
3 B 0
2
5
90%/90%
3
0
(mm) 150
200
250
300
350
400
SENSICK CATALOGUE
251
WT 260 Photoelectric proximity switches, energetic, infrared light -- DC
Dimensional drawing
Scanning distance
10 . . . 3200 mm
■
1
4
78
■
Adjustable sensitivity
Terminal chamber or M 12,
4-pin plug
Test input
16.7
■
63
1,5
25
Photoelectric proximity switches
2
20
33.1
3
max.
15
6
5
3
19.5
50
61
5.5
Adjustments possible
1
2
3
WT 260-F 280
WT 260-F 480
WT 260-E 280
4
6
4
D.ON L.ON
5
7
SENS.
6
7
3
1
4
8
8
2
5
Connection types
C V
Accessories
Cable receptacles
Mounting brackets*
* included with delivery
252
SENSICK CATALOGUE
page
496
510
WT 260-F 280
WT 260-E 280
WT 260-F 480
Terminals
4-pin, M 12
1
L+
1
2
M
2
4
Q
4
3
TE
3
1
3
4
2
L+
M
Q
TE
5.5
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread for cable
diameters from 6 to 10 mm optionally at bottom or
rear; or M 12 equipment plug, bottom
LED signal strength indicator, yellow,
switching output active
Through hole Ø 5.2 mm on both sides for
M 5 hex nut
Sensitivity adjustment
Light/dark rotary switch
L.ON = light-switching, D.ON = dark-switching
Terminals
WT 260
Technical data
WT 260-
Scanning distance
Operating distance
Sensitivity
0 . . . 3200 mm, adjustable 1)
15 . . . 2500 mm, adjustable 1)
Adjustable, potentimeter 270°
Light source 2), light type
Light spot diameter
Angle of dispersion, sender
LED, infrared light
Approx. 80 mm at 2500 mm
Approx. 1.8°
Supply voltage Vs
Ripple 4)
Current consumption 5)
10 . . . 30 V DC 3)
≤ 5 VSS
≤ 35 mA
Switching outputs
PNP, open collector: Q
NPN, open collector: Q
100 mA
Light-/dark-switching by rotary switch
≤ 5.0 ms
100/s
Output current IA max.
Light receiver, switching mode
Response time 6)
Max. switching frequency 7)
Test input ”TE” sender off
PNP: TE to + VS
NPN: TE to 0 V
Connection types
Terminal chamber
Plug M 12, 4-pin
VDE protection class 8)
Circuit protection 9)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) Limit values
4) Must be within VS tolerances
5) Without load
6) With resistive load
7) With light/dark ratio 1:1
8) Reference voltage 50 V DC
F 280 F 480 E 280
A, B, C, D
IP 67
9) A = Vs connections reverse-polarity
protected
B = Inputs/outputs reverse-polarity
protected
C = Interference suppression
D = Outputs overcurrent and short-circuit
protected
Order information
Scanning distance
100
1 10 40 800 1200
1500 2000
3 10 15
2500
0 (mm)2000
■ Operating distance
3200
distance,
■ Scanning
max. typical
1
2
Scanning range on black , 6 % remission
Scanning range on grey, 18 % remission
3
Scanning range on white, 90 % remission
Part no.
6 020 982
WT 260-F 480
WT 260-E 280
6 020 983
6 020 984
90%
3
3000
10
Operating reserve
2 10 15
Type
WT 260-F 280
18%
2
1
6%
1
Operating
distance
Scanning distance, max. typical
(mm) 500
1000 1500 2000 2500 3000 3500
SENSICK CATALOGUE
253
WT 260 Photoelectric proximity switches, energetic, infrared light -- UC
Dimensional drawing
25
Photoelectric proximity switches
■
78
2
3
20
5
6
■
1
4
3
5.5
■
16.7
■
Adjustable sensitivity
Terminal chamber
Universal current supply,
relay output, SPDT, timer optional,
tON and tOFF can be connected
separately
Enclosure rating IP 67
CE noise radiation EN 50081-1
(”Residential standard”)
33.1
■
63
1,5
Scanning distance
10 . . . 3500 mm
19.5
Adjustments possible
1
2
3
WT 260-R 280
WT 260-S 280
4
7
6
SENS.
4
ON. DLY
SENS.
8
5
OFF. DLY
3
1
4
2
5
1
4
2
5
Connection type
WT 260-S 280
WT 260-R 280
C V
3
9
5.5
50
61
5.5
6
7
8
9
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm
optionally at bottom or rear
LED signal strength indicator, red
Through hole l 5.2 mm on both sides
for M 5 hex nut
Sensitivity adjustment
Time control ON-delay tON
Time control OFF-delay tOFF
Terminals
Time delay
t = 0.1 – 10 s
VS
Light received
Relay active
ON
OFF
yes
no
yes
no
tON
Accessories
Mounting brackets*
* included with delivery
page
Terminals
510
1
L1
2
N
4
3
5
254
SENSICK CATALOGUE
tOFF
4
4
4
3
3
3
5
5
5
WT 260
Technical data
WT 260-
Scanning distance, max. typical
Operating distance
Sensitivity
10 . . . 3500 mm, adjustable 1)
20 . . . 3000 mm, adjustable 1)
Adjustable, potentiometer 270°
Light source 2), light type
Light spot diameter
Angle of dispersion, sender
LED, infrared light
Approx. 95 mm at 3000 mm
Approx. 1.7°
Supply voltage VS 3)
Power consumption
12 . . . 240 V DC
24 . . . 240 V AC
≤ 5 VA
Switching output
Switching current I max 4)
Light receiver, switching mode
Response time
Max. switching frequency 5)
Relay, SPDT, electrically isolated
3 A/240 V AC; 3 A/30 V DC
Light-switching
≤ 20 ms
25/s
Time delays
ON delay tON
OFF delay tOFF
0.1. . .10 s, can be connected separately
0.1. . .10 s, can be connected separately
Connection type
CE noise radiation
Terminal chamber
Level EN 50081-1
(”Residential standard”)
VDE protection class 6)
Circuit protection 7)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) ± 10 %
4) Provide suitable spark suppression for
inductive or capacitive loads
5) With light/dark ratio 1:1
S 280 R 280
A, C
IP 67
6) Reference voltage 250 V UC
7) A = Vs connections reverse-polarity
protected
C = Interference suppression
Order information
Type
Part no.
WT 260-S 280
6 020 771
Scanning distance
100
1
30 40
800 1100
WT 260-R 280
3 10 20
0 (mm)
■
6 020 772
1500 2000
3000 3500
1000
2000
Operating distance
■
3000
4000
Scanning distance,
max. typical
1
2
Scanning range on black , 6 % remission
Scanning range on grey, 18 % remission
3
Scanning range on white, 90 % remission
10
90%
3
Operating reserve
2 10 20
18%
2
1
1
(mm)
6%
Operating
distance
Scanning distance, max. typical
1000
2000
3000
SENSICK CATALOGUE
255
WT 260 Photoelectric proximity switches, energetic, red light -- DC
Dimensional drawing
Scanning distance
5 . . . 1500 mm
■
1
4
78
■
Adjustable sensitivity
Terminal chamber or
M 12, 4-pin plug
Test input
16.7
■
63
1.5
25
Photoelectric proximity switches
2
20
33.1
3
max.
15
6
5
3
19.5
50
61
5.5
Adjustments possible
1
2
3
WT 260-F 270
WT 260-F 470
WT 260-E 270
4
6
4
D.ON L.ON
5
7
SENS.
6
7
3
1
4
8
8
2
5
Connection types
C V
Accessories
Cable receptacles
Mounting brackets*
* included with delivery
256
SENSICK CATALOGUE
page
496
510
WT 260-F 270
WT 260-E 270
WT 260-F 470
Terminals
4-pin, M 12
1
L+
1
2
M
2
4
Q
4
3
TE
3
1
3
4
2
L+
M
Q
TE
5.5
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread for cable
diameters from 6 to 10 mm optionally at bottom or
rear; or M 12 equipment plug, bottom
LED signal strength indicator, yellow,
switching output active
Through hole Ø 5.2 mm on both sides for
M 5 hex nut
Sensitivity adjustment
Light/dark rotary switch
L.ON = light-switching, D.ON = dark-switching
Terminals
WT 260
Technical data
WT 260-
Scanning distance
Operating distance
Sensitivity
5 . . .1500 mm, adjustable 1)
5 . . .1000 mm, adjustable 1)
Adjustable, potentimeter 270°
Light source 2), light type
Light spot diameter
Angle of dispersion, sender
LED, infrared light
Approx. 45 mm at 1000 mm
Approx. 2.5°
Supply voltage Vs
Ripple 4)
Current consumption 5)
10 . . . 30 V DC 3)
≤ 5 VSS
≤ 35 mA
Switching outputs
PNP, open collector: Q
NPN, open collector: Q
100 mA
Light-/dark-switching by rotary switch
≤ 1.5 ms
333/s
Output current IA max.
Light receiver, switching mode
Response time 6)
Max. switching frequency 7)
Test input ”TE” sender off
PNP: TE to + VS
NPN: TE to 0 V
Connection types
Terminal chamber
Plug M 12, 4-pin
VDE protection class 8)
Circuit protection 9)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) Limit values
4) Must be within VS tolerances
5) Without load
6) With resistive load
7) With light/dark ratio 1:1
8) Reference voltage 50 V DC
F 270 F 470 E 270
A, B, C, D
IP 67
9) A = Vs connections reverse-polarity
protected
B = Inputs/outputs reverse-polarity
protected
C = Interference suppression
D = Outputs overcurrent and short-circuit
protected
Order information
Type
Part no.
WT 260-F 270
6 020 979
Scanning distance
100
10 20 350 500
2
5 10
3
5
0 (mm) 300
650
WT 260-F 470
WT 260-E 270
900
1000
600
■ Operating distance
900
6 020 980
6 020 981
1500
1200
distance,
■ Scanning
max. typical
1
2
Scanning range on black , 6 % remission
Scanning range on grey, 18 % remission
3
Scanning range on white, 90 % remission
90%
3
1500
10
Operating
distance
Operating reserve
1
6%
1
1
18%
2
Scanning distance, max. typical
(mm)
500
1000
1500
SENSICK CATALOGUE
257
WT 260 Photoelectric proximity switches, energetic, red light -- UC
Dimensional drawing
25
Photoelectric proximity switches
■
78
2
3
20
5
6
■
1
4
3
5.5
■
16.7
■
Adjustable sensitivity
Terminal chamber
Universal current supply,
Relay output, SPDT, timer optional,
tON and tOFF can be connected
separately
Enclosure rating IP 67
CE noise radiation EN 50081-1
(”Residential standard”)
33.1
■
63
1.5
Scanning distance
5 . . . 1700 mm
19.5
Adjustments possible
1
2
3
WT 260-R 270
WT 260-S 270
4
7
6
SENS.
4
ON. DLY
SENS.
8
5
OFF. DLY
3
1
4
2
5
1
4
2
5
Connection type
WT 260-S 270
WT 260-R 270
C V
3
9
5.5
50
61
5.5
6
7
8
9
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm
optionally at bottom or rear
LED signal strength indicator, red
Through hole l 5.2 mm on both sides
for M 5 hex nut
Sensitivity adjustment
Time control ON-delay tON
Time control OFF-delay tOFF
Terminals
Time delay
t = 0.1 – 10 s
VS
Light received
Relay active
ON
OFF
yes
no
yes
no
tON
Accessories
Mounting brackets*
* included with delivery
page
Terminals
510
1
L1
2
N
4
3
5
258
SENSICK CATALOGUE
tOFF
4
4
4
3
3
3
5
5
5
WT 260
Technical data
WT 260-
S 270 R 270
Scanning distance, max. typical
Operating distance
Sensitivity
5 . . .1700 mm, adjustable 1)
5 . . .1300 mm, adjustable 1)
Adjustable, potentiometer 270°
Light source 2), light type
Light spot diameter
Angle of dispersion, sender
LED, infrared light
Approx. 60 mm at 1300 mm
Approx. 1.8°
Supply voltage VS 3)
Power consumption
12 . . . 240 V DC
24 . . . 240 V AC
≤ 5 VA
Switching output
Switching current I max 4)
Light receiver, switching mode
Response time
Max. switching frequency 5)
Relay, SPDT, electrically isolated
3 A/240 V AC; 3 A/30 V DC
Light-switching
≤ 20 ms
25/s
Time delays
ON-delay tON
OFF-delay tOFF
0.1. . .10 s, can be connected separately
0.1. . .10 s, can be connected separately
Connection type
CE noise radiation
Terminal chamber
Level EN 50081-1
(”Residential standard”)
VDE protection class 6)
Circuit protection 7)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) ± 10 %
4) Provide suitable spark suppression for
inductive or capacitive loads
5) With light/dark ratio 1:1
A, C
IP 67
6) Reference voltage 250 V UC
7) A = Vs connections reverse-polarity
protected
C = Interference suppression
Scanning distance
Order information
Type
Part no.
WT 260-S 270
6 020 769
WT 260-R 270
6 020 770
100
1 10 20 400 450
2 5
800 900
1300
0 (mm)
■
500
1000
Operating distance
■
1700
1500
2000
Scanning distance,
max. typical
1
2
Scanning range on black , 6 % remission
Scanning range on grey, 18 % remission
3
Scanning range on white, 90 % remission
10
90%
3
Operating reserve
3 5
2
18%
1
1
Scanning distance, max. typical
6%
(mm)
Operating
distance
500
1000
1500
SENSICK CATALOGUE
259
WL 260 Photoelectric reflex switches, red light -- DC
Dimensional drawing
Scanning range
0.01 . . . 14 m
78
2
3
6
5
max.
15
■
4
20
■
1
16.7
■
Polarising filter providing reliable
detection even of objects with
reflective surfaces
Adjustable sensitivity
Terminal chamber or M 12,
4-pin plug
Test input
33.1
■
63
1.5
25
Photoelectric reflex switches
3
19.5
50
61
5.5
Adjustments possible
1
2
3
WL 260-F 270
WL 260-F 470
WL 260-E 270
4
6
4
D.ON L.ON
5
7
SENS.
6
7
3
1
4
8
8
2
5
Connection types
C V
WL 260-F 270
WL 260-E 270
WL 260-F 470
4-pin, M 12
Accessories
Cable receptacles
page
496
Terminals
Mounting brackets*
Reflector P 250*
510
520
1
* included with delivery
260
SENSICK CATALOGUE
L+
1
2
M
2
4
Q
4
3
TE
3
1
3
4
2
L+
M
Q
TE
5.5
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread for cable
diameters from 6 to 10 mm optionally at bottom or
rear; or M 12 equipment plug, bottom
LED signal strength indicator, yellow,
switching output active
Through hole Ø 5.2 mm on both sides for
M 5 hex nut
Sensitivity adjustment
Light/dark rotary switch
L.ON = light-switching, D.ON = dark-switching
Terminals
WL 260
Technical data
WL 260-
Scanning range, max. typical/ on refl.
max. typical/ on refl.
Operating range
Sensitivity
Light source 1), light type
F 270 F 470 E 270
0.01. . .14 m / PL 80 A
0.01. . . 9.5 m / P 250 (included)
0.01. . . 8 m / P 250
Adjustable, potentiometer 270°
LED, visible red light
with polarising filter
Approx. 240 mm at 8 m
Approx. 1.7°
10 . . . 30 V DC 2)
≤ 5 VSS
≤ 35 mA
PNP, open collector: Q
NPN, open collector: Q
100 mA
Light /dark-switching by rotary switch
≤ 1.5 ms
333/s
Light spot diameter
Angle of dispersion, sender
Supply voltage Vs
Ripple 3)
Current consumption 4)
Switching outputs
Output current IA max.
Light receiver, switching mode
Response time 5)
Max. switching frequency 6)
Test input ”TE” sender off
PNP: TE to + VS
NPN: TE to 0 V
Connection types
Terminal chamber
M 12 plug, 4-pin
VDE protection class 7)
Circuit protection 8)
Enclosure rating
V
Ambient temperature TA
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PMMA
A, B, C, D
IP 67
Weight
Material
5) With resistive load
6) With light/dark ratio 1:1
7) Reference voltage 50 V DC
1) Average service life 100,000 h
at TA = +25 °C
2) Limit values
3) Must be within VS tolerances
4) Without load
8) A = Vs connections reverse-polarity
protected
B = Inputs/outputs reverse-polarity
protected
C = Interference suppression
D = Outputs overcurrent and shortcircuit protected
Scanning range and operating reserve
Order information
Type
Part no.
WL 260-F 270
6 020 976
100
1 0.01
11.5
2 0.01
8
9
7
6 0.02
5.5
4
0 (m)
■
8.5
7
10
6
Operating range
8
■
Operating range
1
PL 80 A
P 250
0.01. . .11.5 m
0.01. . . 8.0 m
PL 50 A or
PL 40 A
PL 30 A or
PL 31 A
PL 20 A
Reflective tape
«Diamond Grade»
0.01. . . 9.0 m
4
5
6
10
Scanning range,
max. typical
Reflector type
2
3
1
5.5
4
6 020 977
6 020 978
11
6
14
Operating reserve
5 0.01
WL 260-F 470
WL 260-E 270
9.5
3 0.01
4 0.01
14
2
Operating
range
5
1
Scanning range, max. typical
(m)
2
4
6
8
10
12
14
0.01. . . 7.0 m
0.01. . . 5.5 m
0.02 . . . 4.0 m
SENSICK CATALOGUE
261
WL 260 Photoelectric reflex switches, red light -- UC
Dimensional drawing
25
Photoelectric reflex switches
■
■
78
4
2
3
20
6
5
3
5.5
■
1
16.7
■
Polarising filter providing reliable
detection even of objects with
reflective surfaces
Terminal chamber
Universal current supply,
relay output, SPDT, timer optional,
tON and tOFF can be connected
separately
Enclosure rating IP 67
CE noise radiation EN 50081-1
(”Residential standard”)
33.1
■
63
1,5
Scanning range
0.01 . . . 15 m
19.5
Adjustments possible
WL 260-S 270
1
2
3
WL 260-R 270
4
7
6
SENS.
ON. DLY
SENS.
8
4
5
OFF. DLY
3
1
4
2
5
1
4
2
5
Connection type
WL 260-S 270
WL 260-R 270
C V
3
9
5.5
50
61
5.5
6
7
8
9
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm
optionally at bottom or rear
LED signal strength indicator, red
Through hole l 5.2 mm on both sides
for M 5 hex nut
Sensitivity adjustment
Time control ON-delay tON
Time control OFF-delay tOFF
Terminals
Time delay
t = 0.1 – 10 s
VS
Light received
Relay active
ON
OFF
yes
no
yes
no
tON
Accessories
Mounting brackets*
Reflector P 250*
* included with delivery
page
510
520
Terminals
1
L1
2
N
4
3
5
262
SENSICK CATALOGUE
tOFF
4
4
4
3
3
3
5
5
5
WL 260
Technical data
WL 260-
S 270 R 270
Scanning range, max. typical/ on refl. 0.01. . .15 m / PL 80 A
max. typical/ on refl. 0.01. . .11 m/ P 250 (included)
Operating range
0.01. . .10 m/ P 250
Sensitivity
Adjustable, potentiometer 270°
Light source 1), light type
LED, visible red light
with polarising filter
Approx. 300 mm at 10 m
Approx. 1.7°
Light spot diameter
Angle of dispersion, sender
Supply voltage Vs2)
12 . . . 240 V DC
24 . . . 240 V AC
≤ 5 VA
Power consumption
Switching output
Switching current IA max. 3)
Light receiver, switching mode
Response time
Max. switching frequency 4)
Time delays
ON delay tON
OFF delay tOFF
Relay, SPDT, electrically isolated
3 A/240 V AC; 3 A/30 V DC
Light-switching
≤ 20 ms
25/s
Connection type
CE noise radiation
Terminal chamber
Level EN 50081-1
(”Residential standard”)
VDE protection class 5)
Circuit protection 6)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PMMA
1) Average service life 100,000 h
at TA = + 25 °C
2) ± 10 %
3) Provide suitable spark suppression for
inductive or capacitive loads
4) With light/dark ratio 1:1
0.1. . .10 s, can be connected separately
0.1. . .10 s, can be connected separately
A, C
IP 67
5) Reference voltage 250 V UC
6) A = Vs connections reverse-polarity
protected
C = Interference suppression
Order information
Type
Part no.
WL 260-S 270
6 020 767
Scanning range and operating reserve
100
1
0.01
2
0.01
3
0.01
4
0.01
5
0.01
6
0.02
13
15
WL 260-R 270
10 11
6 020 768
11.5 12.5
8.5 9.7
4
■
10
5.3 6.5
2
4
6
Operating range
8
■
10
12
Scanning range,
max. typical
Reflector type
Operating range
1
PL 80 A
P 250
0.01. . .13.0 m
0.01. . .10.0 m
PL 50 A or
PL 40 A
PL 30 A or
PL 31 A
PL 20 A
Reflective tape
«Diamond Grade»
0.01. . .11.5 m
2
3
4
5
6
14
16
1
Operating reserve
0 (m)
6.5 7.8
6
Operating
range
1
2
Scanning range, max. typical
(m)
5
10
15
0.01. . . 8.5 m
0.01. . . 6.5 m
0.01. . . 5.3 m
SENSICK CATALOGUE
263
WS/WE 260 Through-beam photoelectric switches, infrared light -- DC
Dimensional drawing
Scanning range
30 m
2
19.5
■
1
3
77.5
■
Adjustable sensitivity
Terminal chamber or M 12,
4-pin plug
Test input
51.5
■
63
1.5
25
Through-beam photoelectric switches
max.
15
5.5
4
2
19.5
50
61
5.5
Adjustments possible
1
2
WS/WE 260-F 230
WS/WE 260-F 430
WS/WE 260-E 230
3
4
3
5
6
7
MODE
L. ON D. ON
6
SENS.
Min. Max.
5
3
1
4
2
7
Connection types
C V
WS/WE 260-F 230
WS/WE 260-E 230
WS/WE 260-F 430
Terminals
4-pin, M 12
WS 260- G 430
WS 260- G 230
Accessories
Cable receptacles M 12
Mounting brackets*
page
496
510
Slotted masks
556
Sender
1
L+
1
2
M
2
3
TE
1
3
4
3
2
L+
M
NC
TE
* included with delivery
Receiver
264
SENSICK CATALOGUE
WE 260- E 230
WE 260- F 230
WE 260- F 430
1
L+
1
2
M
2
4
Q
4
1
3
4
2
L+
M
Q
NC
5.5
Centre of optical axis, sender/receiver
Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm
optionally at bottom or rear;
or M 12 equipment plug, bottom
LED signal strength indicator, red
Through hole l 5.2 mm on both sides
for M 5 hex nut
Sensitivity adjustment
Light/dark rotary switch
L.ON = light-switching, D.ON = dark-switching
Terminals
WS/WE 260
Technical data
WS/WE 260-
Scanning range, max. typical
Operating range
Sensitivity
30 m
20 m
Adjustable, potentiometer 270°
Light source 1), light type
Light spot diameter
Angle of dispersion, sender
Angle of dispersion, receiver
Supply voltage VS
Ripple 3)
Current consumption 4)
sender
receiver
LED, infrared light
Approx. 350 mm at 20 m
Approx. 1°
Approx. 20°
10 . . . 30 V DC 2)
≤ 5 VSS
Switching outputs
Output current IA max.
Light receiver, switching mode
Response time 5)
Max. switching frequency 6)
PNP, open collector: Q
NPN, open collector: Q
100 mA
Light-/dark-switching by rotary switch
≤ 1 ms
500/s
Test input ”TE” sender off
PNP, NPN: TE to 0 V
Connection types
Terminal chamber
M 12 plug, 4 pin
VDE protection class 7)
Circuit protection 8)
sender
receiver
Enclosure rating
V
F 230 F 430 E 230
≤ 20 mA
≤ 35 mA
A, B
A, B, C, D
IP 66
Ambient temperature TA
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
Weight
Material
5) With resistive load
6) With light/dark ratio 1:1
7) Reference voltage 50 V DC
1) Average service life 100000 h
at TA = + 25 °C
2) Limit values
3) Must be within VS tolerances
4) Without load
8) A = Vs connections reverse-polarity
protected
B = Inputs/outputs reverse-polarity
protected
C = Interference suppression
D = Outputs overcurrent and shortcircuit protected
Scanning range and operating reserve
Order information
Type
Part no.
WS/WE 260-F 230 6 020 052
WS/WE 260-E 230 6 020 051
WS/WE 260-F 430 6 020 053
100
1 0
20
2 0
3 0
30
6 7
3
4
4 0 1.5 2
0(m)
4
■ Operating range
8
12
16 20 24 28 30
range,
■ Scanning
max. typical
10
1
2
3
4
Without slotted mask
Slot width 5 mm
Slot width 2 mm
Slot width 1 mm
Operating reserve
Scanning range reduction when using slotted masks
Operating range
Scanning range, max. typical
1
(m)
4
8
12
16
20
24
28
SENSICK CATALOGUE
265
WS/WE 260 Through-beam photoelectric switches, red light -- UC
Dimensional drawing
Scanning range
45 m
■
78
2
4
6
■
1
20
■
2
5.5
■
Adjustable sensitivity
Terminal chamber
Universal current supply,
relay output, SPDT, timer optional,
tON and tOFF can be connected
separately
Enclosure rating IP 67
CE noise radiation EN 50081-1
(”Residential standard”)
3
49.8
■
63
1.5
25
Through-beam photoelectric switches
19.5
Adjustments possible
1
2
WS/WE 260-R 270
WS/WE 260-S 270
3
6
5
SENS.
7
OFF. DLY
3
1
4
2
5
3
8
3
4
ON. DLY
SENS.
1
4
2
5.5
50
61
5.5
5
6
7
8
Centre of optical axis, sender and receiver
Cable entry gland 1/2HH PF thread
for cable diameters from 6 to 10 mm
optionally at bottom or rear
LED signal strength indicator, red
Through hole l 5.2 mm on both sides
for M 5 hex nut
Sensitivity adjustment
Time control ON-delay tON
Time control OFF-delay tOFF
Terminals
5
Connection type
WS/WE 260-S 270
WS/WE 260-R 270
Time delay
t = 0.1 – 10 s
VS
Light received
C V
Relay active
ON
OFF
yes
no
yes
no
tON
Accessories
Mounting brackets*
page
510
Sender
* included with delivery
Receiver
Terminals
WS 260-S 270
1
L1
2
N
WE 260-S 270
WE 260-R 270
1
L1
2
N
4
3
5
266
SENSICK CATALOGUE
tOFF
4
4
4
3
3
3
5
5
5
WS/WE 260
Technical data
WS/WE 260-
Scanning range, max. typical
Operating range
Sensitivity
45 m
40 m
Adjustable, potentiometer 270°
Light source 1), light type
Light spot diameter
Angle of dispersion, sender
Angle of dispersion, receiver
LED, visible red light
Approx. 700 mm at 40 m
Approx. 1°
Approx. 20°
Supply voltage VS2)
12 . . . 240 V DC
24 . . . 240 V AC
Power consumption
Sender
Receiver
≤ 4 VA
≤ 5 VA
Switching output
Switching current IA max. 3)
Light receiver, switching mode
Response time
Max. switching frequency 4)
Relay, SPDT, electrically isolated
3 A/240 V AC; 3 A/30 V DC
Light-switching
≤ 20 ms
25/s
S 270 R 270
Time delays
ON-delay tON
OFF-delay tOFF
0.1. . .10 s, can be connected separately
0.1. . .10 s, can be connected separately
Connection type
Terminal chamber
CE noise radiation
Level EN 50081-1
(”Residential standard”)
VDE protection class 5)
Circuit protection 6)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS; optics: PC
1) Average service life 100,000 h
at TA = + 25 °C
2) ± 10 %
3) Provide suitable spark suppression for
inductive or capacitive loads
4) With light/dark ratio 1:1
A, C
IP 67
5) Reference voltage 250 V UC
6) A = Vs connections reverse-polarity
protected
C = Interference suppression
Scanning range and operating reserve
Order information
100
40
0 (m)
10
20
■ Operating range
30
40
45
Part no.
6 020 773
WS/WE 260-R 270
6 020 774
50
range,
■ Scanning
max. typical
10
Operating reserve
0
Type
WS/WE 260-S 270
Operating range
1
(m)
Scanning range, max. typical
10
20
30
40
50
SENSICK CATALOGUE
267
WLL 260 Photoelectric switches for fibre-optic cable, red light -- DC
Dimensional drawing
Scanning range
max. 800 mm
63
1.5
25
Through-beam systems
4
Scanning distance
max. 65 (110) mm
■
■
■
2
3
19.5
5
5.5
max.
21
■
Wide range of fibre-optic cables
for through-beam and proximity
applications
Easy adaption of fibre-optic cable
using cap nut
Adjustable sensitivity
Terminal chamber, at bottom or
rear or M 12 plug, 4-pin
Test input
39.5
■
12
1
77.5
Proximity systems
3
19.5
Adjustments possible
1
2
3
WLL 260-F 240
WLL 260-F 440
WLL 260-E 240
4
5
6
7
4
8
MODE
L. ON D. ON
7
8
SENS.
Min. Max.
6
3
1
4
2
Connection types
WLL 260-E 240
WLL 260-F 240
WLL 260-F 440
4-pin, M 12
C V
Accessories
Cable receptacles
page
496
Terminals
Mounting brackets*
Fibre-optic cable
510
528
1
* included with delivery
268
SENSICK CATALOGUE
50
61
5.5
L+
1
2
M
4
Q
4
3
TE
3
2
1
3
4
2
L+
M
Q
TE
Centre of optical axis, receiver
Centre of optical axis, sender
Cable entry gland 1/2HH PF thread for cable diameters
from 6 to 10 mm optionally at bottom or rear;
or M 12 equipment plug, bottom
LED signal strength indicator, red
Through hole l 5.2 mm on both sides for M 5 hex nut
Sensitivity adjustment
Light/dark rotary switch
L.ON = light-switching, D.ON = dark-switching
Terminals
WLL 260
Technical data
Suitable fibre-optic cables
Scanning distance/ranges
Through-beam system
Scanning distance, max. typical 1)
Scanning range 1)
WLL 260Fibre-optic cable series LIS/LBS
see page 552
Depends on the fibre-optic cable used
0 . . . 65 mm
0 . . .110 mm w. special fibre-optic cable
0 . . . 50 mm
0 . . . 90 mm w. special fibre-optic cable
Proximity system
Scanning range, max. typical
Operating range
Sensitivity
0 . . . 800 mm
0 . . . 700 mm
Adjustable, potentiometer 270°
Light source 2), light type
Light spot diameter
Aperture fibre-optic cable
LED, visible red light
Depends on scanning range
Approx. 65°
Supply voltage VS
Ripple 4)
Current consumption 5)
10 . . . 30 V DC 3)
≤ 5 VSS
≤ 35 mA
Switching outputs
PNP, open collector: Q
NPN, open collector: Q
100 mA
Light-/dark-switching by rotary switch
≤ 0.7 ms
700/s
Output current IA max.
Light receiver, switching mode
Response time 6)
Max. switching frequency 7)
Test input ”TE” sender off
PNP: TE to + VS
NPN: TE to 0 V
Connection types
Terminal chamber
Plug M 12, 4-pin
VDE protection class 8)
Circuit protection 9)
Enclosure rating
V
Ambient temperature TA
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS
Weight
Material
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) Limit values
4) Must be within VS tolerances
F 240 F 440 E 240
A, B, C, D
IP 66
5) Without load
6) With resistive load
7) With light/dark ratio 1:1
8) Reference voltage 50 V DC
9) A = Vs connections reverse-polarity
protected
B = Inputs/outputs reverse-polarity
protected
C = Interference suppression
D = Outputs overcurrent and shortcircuit protected
Order information
Type
Part no.
WLL 260-F 240
6 020 064
WLL 260-F 440
6 020 065
WLL 260-E 240
6 020 063
SENSICK CATALOGUE
269
WLL 260 Photoelectric switches for fibre-optic cable, red light -- UC
Dimensional drawing
Scanning range
max. 800 mm
63
1.5
25
Through-beam systems
4
Scanning distance
max. 65 (110) mm
■
■
■
3
19.5
5
5.5
2
5.5
■
Wide range of fibre-optic cables
for through-beam and proximity
applications
Easy adaption of fibre-optic cable
using cap nut
Adjustable sensitivity
Terminal chamber, at bottom or rear
Universal current supply, relay
output, SPST, timer optional
39.5
■
12
1
77.5
Proximity systems
Adjustments possible
WLL 260-R 240
4
MODE
1 2 3 4
OUTPUT TIMER
1 O.S.D.
2 OFF.D.
3 ON.D.
4 NORMAL
1
TIMER
4
MODE
8
L.ON D.ON 0.1 5(SEC)
MODE
L. ON D. ON
7
SENS.
SENS.
7
6
3
1
4
2
9
3
C V
2
5.5
50
61
5.5
WLL 260-S 240
6
3
19.5
1 Centre of optical axis, receiver
2 Centre of optical axis, sender
3 Cable entry gland 1/2HH PF thread for cable
diameters from 6 to 10 mm optionally at
bottom or rear
4 LED signal strength indicator, red
1 0
5 Through hole l 5.2 mm on both sides
for M 5 hex nut
1 1
6 Sensitivity adjustment
7 Light/dark rotary switch
L.ON = light-switching,
D.ON = dark-switching
8 Time range control
9 Terminals
1 0 Red LED status indicator, switching output
active
1 1 Time delay selector switch
O.S.D. = One Shot
OFF.D. = OFF delay
ON.D. = ON delay
Normal = No delay
Connection type
Time delay
WLL 260-S 240
WLL 260-R 240
t = 0.1 – 5 s
Light
beam
Mode
NORMAL
1 23 4
O.S.D.
T
1 23 4
Accessories
Mounting brackets*
Fibre-optic cable
* included with delivery
page
510
528
OFF.D.
Terminals
1 23 4
1
V DC
2
V AC
ON.D.
1 23 4
3
4
270
SENSICK CATALOGUE
T
T
T
T
T
T
T
T
T
T
T
T
T
Switching mode: X light-switching
x dark-switching
Uninterrupted
Interrupted
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
WLL 260
Technical data
WLL 260-
Suitable fibre-optic cable
Scanning distance/ranges
Through-beam system
Scanning distance, max. typical 1)
Scanning range 1)
Fibre-optic cable series LIS/LBS
see page 552
Depends on the fibre-optic cable used
0 . . . 65 mm
0 . . .110 mm w. special fibre-optic cable
0 . . . 50 mm
0 . . . 90 mm w. special fibre-optic cable
Proximity system
Scanning range, max. typical
Operating range
Sensitivity
0 . . . 800 mm
0 . . . 700 mm
Adjustable, potentiometer 270°
Light source 2), light type
Light spot diameter
Aperture fibre-optic cable
LED, visible red light
Depends on scanning range
Approx. 65°
Supply voltage VS3)
Power consumption
12 . . . 240 V DC
24 . . . 240 V AC
≤ 5 VA
Switching output
Switching current IA max. 4)
Light receiver, switching mode
Response time
Max. switching frequency 5)
Relay, SPST, electrically isolated
3 A/240 V AC; 3 A/30 V DC
Light-/dark-switching by rotary switch
≤ 20 ms
25/s
Time delays
With indicator LED: switching
output active
1: «One shot»
OFF delay tOFF
ON delay tON
No delay
Adjustable, 0.1. . . 5 s;
potentiometer 270°
Switch position:
«1 O.S.D.»
«2 OFF.D.»
«3 ON.D.»
«4 Normal»
Time range
S 240 R 440
Connection type
Terminal chamber
VDE protection class 6)
Circuit protection 7)
Enclosure rating
V
Ambient temperature TA
Weight
Material
Operation – 25 °C . . . + 55 °C
Storage – 40 °C . . . + 70 °C
Approx. 120 g
Housing: ABS
1) Object with 90 % remission (based on
standard white DIN 5033)
2) Average service life 100,000 h
at TA = + 25 °C
3) ± 10 %
4) Provide suitable spark suppression for
inductive or capacitive loads
5) With light/dark ratio 1:1
A, C
IP 66
6) Reference voltage 50 V DC
7) A = Vs connections reverse-polarity
protected
C = Interference suppression
Order information
Type
Part no.
WLL 260-S 240
6 009 504
WLL 260-R 240
6 009 503
SENSICK CATALOGUE
271