Single head system Dimensions UCC1000-30GM-E6-V1 96 5 13.5 ø32 36 LED Temperature probe Coded plug M30x1.5 Features • 2 independent switch points • High chemical resistance through teflon-cated transducer surface • Switch point can be taught-in • Window function can be selected Technische Technical data Daten • Temperature compensation • Compact construction General specifications • Plug connection Sensing range Standard target plate Unusable area Transducer frequency Response delay Standard conformity Indicating/Operating means LED yellow 200 ... 1000 mm 100 mm x 100 mm 0 ... 200 mm approx. 175 kHz ≤ 100 ms EN 60947-5-2 Power consumption P0 Output Output type Rated operational current Ie Voltage drop Ud Switching frequency f Range hysteresis H Repeat accuracy Temperature influence ≤ 600 mW Switching state output 1, TEACH-IN function output 1 switching state output 2, TEACH-IN function output 2 permanent green: Power on green, flashing: TEACH-IN function, LED red/green object detected permanently red: Connector removed red, flashing: Error, teach-in function object not detected Temperature/TEACH-IN connector Temperature compensation, TEACH-IN of the switch points, output function change over Electrical specifications 10 ... 30 V DC, ripple 10 %SS Rated operational voltage Ue Standard symbol/Connection: 1 U 2 4 3 + UB Switch output 1 Switch output 2 - UB Ambient conditions Ambient temperature Storage temperature Mechanical specifications Protection degree Connection type Material Housing Transducer < 2 % of full-scale value (≤ 0.2 % / K without temperature compensation) -25 ... +70 °C (248 ... 343 K) -40 ... +85 °C (233 ... 358 K) IP65 according to EN 60529 V1 connector (M12 x 1), 4 pin high grade steel (stainless), PTB epoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE coated 153 g 17.08.2001 Mass ≤ 3 V DC ≥ 5 Hz ≤ 3.2 % of the set operating distance ≤1% 052202_e Electrical connection 2 switch outputs pnp, NO/NC 200 mA, short circuit/overload protected Subject to reasonable modifications due to technical advances. 3 Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com Note Hinweise Model number UCC1000-30GM-E6-V1 Notes: This ultrasonic sensor features a four-pole temperature/TEACH-IN plug that can be connected in four different positions. These have the following significance. Characteristic curves/ Additional information Plug position Meaning A1 Teach switching point A1 A2 Teach switching point A2 E2/E3 Switching: 2 independent switching positions/window function T Temperature compensation Characteristic response curves 90 80 70 60 50 40 Angle [degrees] 30 20 Description of the TEACH-IN procedure: - Remove temperature plug - Cut and restore supply voltage (e.g. by removing and replacing unit plug) 10 2 0.0 TEACH-IN of switching points 1 and 2: - Set object to desired switching point - Connect TEACH-IN plug in pos. A1 or A2 - Green LED flashes when object detected, red LED flashes when no object detected - Pull the plug (the current object position is taught and stored when the plug is removed!) TEACH-IN of switching function: - Connect TEACH-IN plug in pos. E2/E3 - The yellow LED indicates the switching function E2: 2 independent switching points (NO) E3: window function: switch output 1 NO, switch output 2 NC - Pull the plug when the desired function is activated, otherwise reconnect the TEACH-IN plug in pos. E2/E3 - Pull plug 1 -0 0.2 0.4 -10 0.6 0.8 -20 1.0 Distance [m] 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 Curve 1: flat plate 100 mm x 100 mm Curve 2: round bar, Ø 25 mm Programmed switching output function Position of insert Switch output functions Switch point 1 Switch point 2 A 1 (N.O.) Switch output 1 E2 A 2 (N.O.) Switch output 2 Completing the TEACH-IN procedure: - Connect TEACH-IN plug in pos. T. Temperature compensation is now activated. A 1 (N.O.) Switch output 1 E3 Note: If the temperature plug has not been plugged in within 5 minutes, the sensor will return to normal mode without temperature compensation. Displays depending on position of temperature/ TEACH-IN plug position Green Red dual Yellow dual LED LED LED A1/E2 Yellow LED A2/E3 Teach switching point output A1 Object detected No object detected Flashing Off Flashing Off Off Flashing Flashing Off LED-Window LED yellow Dual-LED green/red LED yellow E2 Teach switching point output A2 Object detected No object detected Flashing Off Off Off Flashing Off TEACH-IN of switch output functions: E2: 2 independent switching positions E3: window function On On Off Off Flashing Off Off Flashing Normal mode, temperature compensated On Off Switching state A1 Switching state A2 Plug pulled or shorted Off On Switching state A1 Switching state A2 Interference (e.g. compressed air) Off Flashing Previous Previous state state Subject to reasonable modifications due to technical advances. A2 (N.C.) Switch output 2 Flashing Flashing Switch output 1 E3 A1 A2 Switch output 2 "Power on"/Disturbance Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com 4