ETC 52202

Single head system
Dimensions
UCC1000-30GM-E6-V1
96
5
13.5
ø32
36
LED
Temperature probe
Coded plug
M30x1.5
Features
• 2 independent switch points
• High chemical resistance through teflon-cated transducer surface
• Switch point can be taught-in
• Window function can be selected
Technische
Technical
data
Daten
• Temperature compensation
• Compact construction
General specifications
• Plug connection
Sensing range
Standard target plate
Unusable area
Transducer frequency
Response delay
Standard conformity
Indicating/Operating means
LED yellow
200 ... 1000 mm
100 mm x 100 mm
0 ... 200 mm
approx. 175 kHz
≤ 100 ms
EN 60947-5-2
Power consumption
P0
Output
Output type
Rated operational current Ie
Voltage drop
Ud
Switching frequency
f
Range hysteresis
H
Repeat accuracy
Temperature influence
≤ 600 mW
Switching state output 1, TEACH-IN function output 1
switching state output 2, TEACH-IN function output 2
permanent green: Power on green, flashing: TEACH-IN function,
LED red/green
object detected permanently red: Connector removed red, flashing:
Error, teach-in function object not detected
Temperature/TEACH-IN connector Temperature compensation, TEACH-IN of the switch points, output
function change over
Electrical specifications
10 ... 30 V DC, ripple 10 %SS
Rated operational voltage Ue
Standard symbol/Connection:
1
U
2
4
3
+ UB
Switch output 1
Switch output 2
- UB
Ambient conditions
Ambient temperature
Storage temperature
Mechanical specifications
Protection degree
Connection type
Material
Housing
Transducer
< 2 % of full-scale value
(≤ 0.2 % / K without temperature compensation)
-25 ... +70 °C (248 ... 343 K)
-40 ... +85 °C (233 ... 358 K)
IP65 according to EN 60529
V1 connector (M12 x 1), 4 pin
high grade steel (stainless), PTB
epoxy resin/hollow glass bead mixture; Polyurethane foam, PTFE
coated
153 g
17.08.2001
Mass
≤ 3 V DC
≥ 5 Hz
≤ 3.2 % of the set operating distance
≤1%
052202_e
Electrical connection
2 switch outputs pnp, NO/NC
200 mA, short circuit/overload protected
Subject to reasonable modifications due to technical advances.
3
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com
Note
Hinweise
Model number
UCC1000-30GM-E6-V1
Notes:
This ultrasonic sensor features a four-pole temperature/TEACH-IN plug that can be
connected in four different positions. These have the following significance.
Characteristic curves/
Additional information
Plug position
Meaning
A1
Teach switching point A1
A2
Teach switching point A2
E2/E3
Switching: 2 independent switching positions/window function
T
Temperature compensation
Characteristic response curves
90
80
70
60
50
40
Angle [degrees]
30
20
Description of the TEACH-IN procedure:
- Remove temperature plug
- Cut and restore supply voltage (e.g. by removing and replacing unit plug)
10
2
0.0
TEACH-IN of switching points 1 and 2:
- Set object to desired switching point
- Connect TEACH-IN plug in pos. A1 or A2
- Green LED flashes when object detected, red LED flashes when no object detected
- Pull the plug (the current object position is taught and stored when the plug is removed!)
TEACH-IN of switching function:
- Connect TEACH-IN plug in pos. E2/E3
- The yellow LED indicates the switching function
E2: 2 independent switching points (NO)
E3: window function: switch output 1 NO, switch output 2 NC
- Pull the plug when the desired function is activated, otherwise reconnect the
TEACH-IN plug in pos. E2/E3
- Pull plug
1
-0
0.2
0.4
-10
0.6
0.8
-20
1.0
Distance [m]
1.2
1.4
1.6
1.8
2.0
2.2
2.4
2.6
Curve 1: flat plate 100 mm x 100 mm
Curve 2: round bar, Ø 25 mm
Programmed switching output function
Position of insert
Switch output functions
Switch point 1
Switch point 2
A 1 (N.O.)
Switch output 1
E2
A 2 (N.O.)
Switch output 2
Completing the TEACH-IN procedure:
- Connect TEACH-IN plug in pos. T. Temperature compensation is now activated.
A 1 (N.O.)
Switch output 1
E3
Note:
If the temperature plug has not been plugged in within 5 minutes, the sensor will
return to normal mode without temperature compensation.
Displays depending on position of temperature/
TEACH-IN plug position
Green
Red dual Yellow
dual LED LED
LED
A1/E2
Yellow
LED
A2/E3
Teach switching point output A1
Object detected
No object detected
Flashing Off
Flashing Off
Off
Flashing Flashing Off
LED-Window
LED
yellow
Dual-LED
green/red
LED
yellow
E2
Teach switching point output A2
Object detected
No object detected
Flashing Off
Off
Off
Flashing Off
TEACH-IN of switch output functions:
E2: 2 independent switching positions
E3: window function
On
On
Off
Off
Flashing Off
Off
Flashing
Normal mode, temperature compensated On
Off
Switching
state A1
Switching
state A2
Plug pulled or shorted
Off
On
Switching
state A1
Switching
state A2
Interference (e.g. compressed air)
Off
Flashing Previous Previous
state
state
Subject to reasonable modifications due to technical advances.
A2 (N.C.)
Switch output 2
Flashing
Flashing
Switch output 1
E3
A1
A2
Switch output 2
"Power on"/Disturbance
Copyright Pepperl+Fuchs, Printed in Germany
Pepperl+Fuchs Group • Tel.: Germany (06 21) 7 76-0 • USA (330) 4 25 35 55 • Singapore 7 79 90 91 • Internet http://www.pepperl-fuchs.com