DBLECTRO NT90TPNBDDC48VS

Présente / Presents:
DB LECTRO Inc. 3755 Place Java, Suite 140, Brossard, Québec, J4Y 0E4, Canada - T: 1-450-444-1424 / F: 1-450-444-4714 / www.dblectro.com
NT90TP (T92)
NT90TP (T92)
03001003503
E9930952
R
32.4(50)
27
20
32.4(50) 27
R2033977.07
C
US E160644
Patent No.02110881.1
28.5
Features
Small size, light weight. Low coil power consumption, heavy contact load. Strong anti-shock and anti-vibration, high
reliability, long life.
Suitable for automobile, machine, electronic equipment, air conditioner and household appliances applications.
Ordering Information
N90TP
1
1
2
3
4
5
H
2
L
3
A S
4
5
DC12V
C
6
Part number NT90TP T92
NT90TP 2
Load H:30A N:40A
High NIL: Standard L: Low profile type
Contact arrangement A:1A B:1B C:1C
Enclosure S: Sealed type D: Dust cover
E: Covered
7
B
8
0.9
9
6 Coil rated Voltage(V) AC:12,24, 110,120,220
DC:3,5,6,9,12,15,18,24,48,110
7 Contact material C: AgCdO S: AgSnO2 ; I: AgSnO2 In 2O 3
8 Resist heat class B:130
F:155
9 Coil power consumption 0.6:0.6W 0.9:0.9W
NIL:2VA
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
1A SPSTNO
1B SPSTNC
1C
AgCdO
AgSnO2 AgSnO2In 2O 3
SPDT(B-M)
NO:30A/240VAC,14VDC;
NC:20A/240VAC;30A/14VDC
NO:40A/250VAC,30VDC; NC:30A/250VAC,30VDC (0.9W)
NO:30A/277VAC;NC:20A/277VAC
Motor load 2HP 250VAC 1.5HP 250V
Lamp load TV-5
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation
Electrical
life
Mechanical
1100W 7200VA
110VDC 250VAC
30m
105
107
Max. Switching Current:40A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Coil Parameter
AC Coil Parameter
Dash
numbers
012AC
024AC
110AC
120AC
220AC
Rated voltage
VAC
Rated
Max
12
24
110
120
220
15.6
31.2
143
156
286
Rated
current
mA
187
95
20
16.5
6.4
Coil
resistance
10%
27
120
2360
3040
13490
Pick up
voltage
VAC(max)
(75%of
rated
voltage)
Release
voltage
VAC(min)
(30%of
rated
voltage)
Coil
power
9.0
18.0
82.5
90.0
165.0
3.6
7.2
33.0
36.0
66.0
2VA
Operate
Time
ms
Release
Time
ms
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Ningbo Huaguan Relay Corporation LTD.
NHG RELAYS
Coil Parameter
DC Coil Parameter
Dash
numbers
Rated voltage
VDC
Coil
resistance
10%
Pick up
voltage
VDC(max)
(75%of
rated
voltage)
Release
voltage
VDC(min)
(10%of
rated
voltage)
Rated
Max
003-900
005-900
006-900
009-900
012-900
015-900
018-900
024-900
036-900
048-900
110-900
3
5
6
9
12
15
18
24
36
48
110
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
46.8
62.4
143
10
28
40
90
160
250
360
640
1440
2560
13445
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
27.00
36.00
82.50
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
3.6
4.8
11.0
003-600
005-600
006-600
009-600
012-600
015-600
018-600
024-600
048-600
110-600
3
5
6
9
12
15
18
24
48
110
3.9
6.5
7.8
11.7
15.6
19.5
23.4
31.2
62.4
143
15
42
60
135
240
375
540
960
3840
20167
2.25
3.75
4.50
6.75
9.00
10.25
13.50
18.00
36.00
82.50
0.3
0.5
0.6
0.9
1.2
1.5
1.8
2.4
4.8
11.0
Coil
power
W
Operate
Time
ms
Release
Time
ms
0.9
15
10
0.6
15
10
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
Operation condition
Insulation Resistance
Dielectric Strength
1000M
Between contacts
Between contact and coil
50Hz 1500V
50Hz 2500V
Shock resistance
Vibration resistance
Terminals strength
Solderability
Ambient Temperature
Relative Humidity
Mass
min (at 500VDC)
2
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
200m/s
11ms
10~55Hz double amplitude 1.5mm
10N
235
2
3 0.5s
-55~100
-55~125
85% (at 40 )
35g Low profile type 37g
IEC68-2-27 Test Ea
IEC68-2-6 Test Fc
IEC68-2-21 Test Ua2
IEC68-2-20 Test Ta method 1
IEC68-2-3 Test Ca
Qualification inspection:
Perform the qualification test as specified in the table
of IEC255-19-1 and minimum sample size 24.
Safety approvals
Safety approval
UL&CUR
T V
Load
NO:40A/240VAC 30A/277VAC
NC:30A/240VAC 20A/277VAC
2HP 250VAC TV-5
1 12 HP 250VAC
HP:A 1HP/16AFLA/120VAC
2HP/12AFLA/240VAC
B 30LRA/10AFLA/120VAC
30LRA/10AFLA/240VAC
Insulation B-class
F-class
NO:40A/240VAC 14VDC
NC:30A/240VAC 14VDC
Insulation B-class
F-class
CQC
NO:30A/240VAC
NC:20A/240VAC
NT90TP (T92)
Dimensions
mm /inch
43.5
1.713
43.5
2-0.5x2.8
0.020
1.713
0.110
2-0.5x2.8
15.4
0.020 0.110
0.606
2-R1.8
15.4
0.401
7.8
0.307
0.252
0.110
6.4
2.8
2.8
0.704
0.110
0.142
0.008
3.6
3.8 0.2
7.7
17.9
27.5Max.
1.063max.
0.787max. 0.307
2.2
1.102max.
50.2Max.
1.976max.
50.2
1.976max.
20Max. 7.8
32.5Max.
1.280max.
0.087
2
NC
0.303
27.5 Max.
1.063max.
0.079 28 Max.
32.5Max.
1.280max.
NO
COM
0.150
10.2
0.401
7.8
2.8
0.110
6.4
2.8
0.303
17.9
0.704
0.110
3.8 0.2
7.7
0.307
NC
0.252
NO
COM
0.150 0.008
3.6
0.606
2-R1.8
R0.071
0.142
10.2
R0.071
NT90TP
0.189
0.031
0.252
2.8
0.110
0.007
7.7 0.2
0.303
0.007
2.2
COM
1.110max.
27.5 Max.
1.083max.
28.2 Max.
32.5Max.
1.280max.
N0
COM
3-6.4X0.8
15.4 0.2
0.606
0.087
COM
0.007
3.6
N0
NC
0.484 0.007
R0.071
15.4 0.2
NC
12.3 0.2
0.020 0.315
2-R1.8
COM
NT90TP 2
2-0.5X4.8
0.142
N0
0.401
10.2 0.2
NC
0.007
43.5
1.713
50.2Max.
1.976max.
NT90TP
Wiring diagram
NOTES 1). Dimensions are in millimeters.
2). Inch equivalents are given for general information only.
NT90TP2
Dimensions
Reference Data
Time (m sec)
12
10
8
6
4
Ningbo Huaguan Relay Corporation LTD.