TPS5210 PROGRAMMABLE SYNCHRONOUS-BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 D D D D D D D D D D D D ±1% Reference Over Full Operating Temperature Range Synchronous Rectifier Driver for Greater Than 90% Efficiency Programmable Reference Voltage Range of 1.3 V to 3.5 V User–Selectable Hysteretic Type Control Droop Compensation for Improved Load Transient Regulation Adjustable Overcurrent Protection Programmable Softstart Overvoltage Protection Active Deadtime Control Power Good Output Internal Bootstrap Schottky Diode Low Supply Current . . . 3-mA Typ DW OR PWP PACKAGE (TOP VIEW) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 IOUT DROOP OCP VHYST VREFB VSENSE ANAGND SLOWST BIAS LODRV LOHIB DRVGND LOWDR DRV 28 27 26 25 24 23 22 21 20 19 18 17 16 15 PWRGD VID0 VID1 VID2 VID3 VID4 INHIBIT IOUTLO LOSENSE HISENSE BOOTLO HIGHDR BOOT VCC description The TPS5210 is a synchronous-buck regulator controller which provides an accurate, programmable supply voltage to microprocessors. An internal 5-bit DAC is used to program the reference voltage to within a range of 1.3 V to 3.5 V. The output voltage can be set to be equal to the reference voltage or to some multiple of the reference voltage. A hysteretic controller with user-selectable hysteresis and programmable droop compensation is used to dramatically reduce overshoot and undershoot caused by load transients. Propagation delay from the comparator inputs to the output drivers is less than 250 ns. Overcurrent shutdown and crossover protection for the output drivers combine to eliminate destructive faults in the output FETs. The softstart current source is proportional to the reference voltage, thereby eliminating variation of the softstart timing when changes are made to the output voltage. PWRGD monitors the output voltage and pulls the open-collector output low when the output drops 7% below the nominal output voltage. An overvoltage circuit disables the output drivers if the output voltage rises 15% above the nominal value. The inhibit pin can be used to control power sequencing. Inhibit and undervoltage lockout assures the 12-V supply voltage and system supply voltage (5 V or 3.3 V) are within proper operating limits before the controller starts. Single-supply (12 V) operation is easily accomplished using a low-current divider for the required 5-V signals. The output driver circuits include 2-A drivers with internal 8-V gate-voltage regulators. The high-side driver can be configured either as a ground-referenced driver or as a floating bootstrap driver. The TPS5210 is available in a 28-pin SOIC package and a 28-pin TSSOP PowerPAD package. It operates over a junction temperature range of 0°C to 125°C. AVAILABLE OPTIONS PACKAGES TJ SOIC (DW) 0°C to 125°C TPS5210DW TSSOP (PWP) TPS5210PWPR The DW package is available taped and reeled. Add R suffix to device type (e.g., TPS5210DWR). Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 1999, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 1 INHIBIT 15 7 28 LOSENSE 20 21 19 NOCPU 2V 22 + – UVLO Shutdown S VCC Rising Edge Delay Deglitch HIGHDR Deglitch VPGD 0.93 Vref VOVP 1.15 Vref HIGHIN VCC VSENSE 8 PREREG Analog Bias + – Bandgap Analog Bias 9 IVREFB 5 – + Slowstart Comp 14 DRV REG Shutdown 16 CM Filters VID MUX and Decoder 17 + VREF Σ + – – + – 27 26 IOUT 2x Fault R 25 24 23 Hysteresis Comp Shutdown 200 kΩ Hysteresis Setting I VREFB POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 1 Q + 100 mV SLOWST IOUTLO HISENSE 11111 Decode 10 V OCP PWRGD 2 4 13 6 VID0 VID1 VID2 VID3 VID4 VREFB DROOP VHYST VSENSE 11 10 LOHIB LODRV DRV BOOT HIGHDR 200 kΩ 18 BOOTLO 12 5 BIAS LOWDR DRVGND SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 VID0 VID1 VID2 VID3 VID4 ANAGND functional block diagram 2 VCC TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 Terminal Functions TERMINAL NAME NO. I/O DESCRIPTION ANAGND 7 BIAS 9 O Analog ground Analog BIAS pin. A 1-µF ceramic capacitor should be connected from BIAS to ANAGND. BOOT 16 I Bootstrap. Connect a 1-µF low-ESR capacitor from BOOT to BOOTLO. BOOTLO 18 O Bootstrap low. Connect BOOTLO to the junction of the high-side and low-side FETs for floating drive configuration. Connect BOOTLO to PGND for ground reference drive configuration. DROOP 2 I Droop voltage. Voltage input used to set the amount of output-voltage set-point droop as a function of load current. The amount of droop compensation is set with a resistor divider between IOUT and ANAGND. DRV 14 O Drive regulator for the FET drivers. A 1-µF ceramic capacitor should be connected from DRV to DRVGND. DRVGND 12 HIGHDR 17 O High drive. Output drive to high-side power switching FETs HISENSE 19 I High current sense. For current sensing across high-side FETs, connect to the drain of the high-side FETs; for optional resistor sensing scheme, connect to power supply side of current-sense resistor placed in series with high-side FET drain. INHIBIT 22 I Disables the drive signals to the MOSFET drivers. Can also serve as UVLO for system logic supply (either 3.3 V or 5 V). IOUT 1 O Current out. Output voltage on this pin is proportional to the load current as measured across the Rds(on) of the high-side FETs. The voltage on this pin equals 2×Rds(on)×IOUT. In applications where very accurate current sensing is required, a sense resistor should be connected between the input supply and the drain of the high-side FETs. IOUTLO 21 O Current sense low output. This is the voltage on the LOSENSE pin when the high-side FETs are on. A ceramic capacitor should be connected from IOUTLO to HISENSE to hold the sensed voltage while the high-side FETs are off. Capacitance range should be between 0.033 µF and 0.1 µF. LODRV 10 I Low drive enable. Normally tied to 5 V. To activate the low-side FETs as a crowbar, pull LODRV low. LOHIB 11 I Low side inhibit. Connect to the junction of the high and low side FETs to control the anti-cross-conduction and eliminate shoot-through current. Disabled when configured in crowbar mode. LOSENSE 20 I Low current sense. For current sensing across high-side FETs, connect to the source of the high-side FETs; for optional resistor sensing scheme, connect to high-side FET drain side of current-sense resistor placed in series with high-side FET drain. LOWDR 13 O Low drive. Output drive to synchronous rectifier FETs OCP 3 I Over current protection. Current limit trip point is set with a resistor divider between IOUT and ANAGND. PWRGD 28 O Power good. Power Good signal goes high when output voltage is within 7% of voltage set by VID pins. Open-drain output. SLOWST 8 O Slow Start (soft start). A capacitor from SLOWST to ANAGND sets the slowstart time. Slowstart current = IVREFB/5 VCC 15 VHYST 4 I HYSTERESIS set pin. The hysteresis is set with a resistor divider from VREFB to ANAGND. The hysteresis window = 2 × (VREFB – VHYST) VID0 27 I Voltage Identification input 0 VID1 26 I Voltage Identification input 1 VID2 25 I Voltage Identification input 2 VID3 24 I Voltage Identification input 3 VID4 23 I Voltage Identification input 4. Digital inputs that set the output voltage of the converter. The code pattern for setting the output voltage is located in Table 1. Internally pulled up to 5 V with a resistor divider biased from VCC. VREFB 5 O Buffered reference voltage from VID network VSENSE 6 I Voltage sense Input. To be connected to converter output voltage bus to sense and control output voltage. It is recommended an RC low pass filter be connected at this pin to filter noise. Drive ground. Ground for FET drivers. Connect to FET PWRGND. 12-V supply. A 1-µF ceramic capacitor should be connected from VCC to DRVGND. POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 3 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 detailed description VREF The reference/voltage identification (VID) section consists of a temperature-compensated bandgap reference and a 5-bit voltage selection network. The 5 VID terminals are inputs to the VID selection network and are TTL-compatible inputs internally pulled up to 5 V by a resistor divider connected to VCC. The VID codes conform to the Intel VRM 8.3 DC-DC Converter Specification for voltage settings between 1.8 V and 3.5 V, and they are decremented by 50 mV, down to 1.3 V, for the lower VID settings. Voltages higher than VREF can be implemented using an external divider. Refer to Table 1 for the VID code settings. The output voltage of the VID network, VREF, is within ±1% of the nominal setting over the VID range of 1.3 V to 2.5 V, including a junction temperature range of 5°C to +125°C, and a VCC supply voltage range of 11.4 V to 12.6 V. The output of the reference/VID network is indirectly brought out through a buffer to the VREFB pin. The voltage on this pin will be within 2% of VREF. It is not recommended to drive loads with VREFB, other than setting the hysteresis of the hysteretic comparator, because the current drawn from VREFB sets the charging current for the slowstart capacitor. Refer to the slowstart section for additional information. hysteretic comparator The hysteretic comparator regulates the output voltage of the synchronous-buck converter. The hysteresis is set by 2 external resistors and is centered on VREF. The 2 external resistors form a resistor divider from VREFB to ANAGND, with the output voltage connecting to the VHYST pin. The hysteresis of the comparator will be equal to twice the voltage difference between the VREFB and VHYST pins. The propagation delay from the comparator inputs to the driver outputs is 250 ns (maximum). The maximum hysteresis setting is 60 mV. low-side driver The low-side driver is designed to drive low-Rds(on) n-channel MOSFETs. The current rating of the driver is 2 A, source and sink. The bias to the low-side driver is internally connected to the DRV regulator. high-side driver The high-side driver is designed to drive low-Rds(on) n-channel MOSFETs. The current rating of the driver is 2 A, source and sink. The high-side driver can be configured either as a ground-referenced driver or as a floating bootstrap driver. When configured as a floating driver, the bias voltage to the driver is developed from the DRV regulator. The internal bootstrap diode, connected between the DRV and BOOT pins, is a Schottky for improved drive efficiency. The maximum voltage that can be applied between BOOT and DRVGND is 30 V. The driver can be referenced to ground by connecting BOOTLO to DRVGND, and connecting BOOT to either DRV or VCC. deadtime control Deadtime control prevents shoot-through current from flowing through the main power FETs during switching transitions by actively controlling the turn-on times of the MOSFET drivers. The high-side driver is not allowed to turn on until the gate-drive voltage to the low-side FETs is below 2 V; the low-side driver is not allowed to turn on until the voltage at the junction of the high-side and low-side FETs (Vphase) is below 2 V. current sensing Current sensing is achieved by sampling and holding the voltage across the high-side power FETs while the high-side FETs are on. The sampling network consists of an internal 60-Ω switch and an external ceramic hold capacitor. Recommended value of the hold capacitor is between 0.033 µF and 0.1 µF. Internal logic controls the turn-on and turn-off of the sample/hold switch such that the switch does not turn on until the Vphase voltage transitions high, and the switch turns off when the input to the high-side driver goes low. The sampling will occur only when the high-side FETs are conducting current. The voltage on the IOUT pin equals 2 times the sensed high-side voltage. In applications where a higher accuracy in current sensing is required, a sense resistor can be placed in series with the high-side FETs, and the voltage across the sense resistor can be sampled by the current sensing circuit. 4 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 detailed description (continued) droop compensation The droop compensation network reduces the load transient overshoot/undershoot on VO, relative to VREF . VO is programmed to a voltage greater than VREF by an external resistor divider from VO to VSENSE to reduce the undershoot on VO during a low-to-high load transient. The overshoot during a high-to-low load transient is reduced by subtracting the voltage on DROOP from VREF. The voltage on IOUT is divided with an external resistor divider, and connected to DROOP. inhibit INHIBIT is a TTL-compatible digital input used to enable the controller. When INHIBIT is low, the output drivers are low and the slowstart capacitor is discharged. When INHIBIT goes high, the short across the slowstart capacitor is released and normal converter operation begins. When the system-logic supply is connected to INHIBIT, it also controls power sequencing by locking out controller operation until the system-logic supply exceeds the input threshold voltage of the inhibit circuit. The 12-V supply and the system logic supply (either 5 V or 3.3 V) must be above UVLO thresholds before the controller is allowed to start up. The start threshold is 2.1 V and the hysteresis is 100 mV for the INHIBIT comparator. VCC undervoltage lockout (UVLO) The undervoltage lockout circuit disables the controller while the VCC supply is below the 10-V start threshold during power up. When the controller is disabled, the output drivers will be low and the slowstart capacitor is discharged. When VCC exceeds the start threshold, the short across the slowstart capacitor is released and normal converter operation begins. There is a 2-V hysteresis in the undervoltage lockout circuit for noise immunity. slowstart The slowstart circuit controls the rate at which VO powers up. A capacitor is connected between SLOWST and ANAGND and is charged by an internal current source. The current source is proportional to the reference voltage, so that the charging rate of Cslowst is proportional to the reference voltage. By making the charging current proportional to VREF, the power-up time for VO will be independent of VREF. Thus, CSLOWST can remain the same value for all VID settings. The slowstart charging current is determined by the following equation: Islowstart = I(VREFB) / 5 (amps) Where I(VREFB) is the current flowing out of VREFB. It is recommended that no additional loads be connected to VREFB, other than the resistor divider for setting the hysteresis voltage. The maximum current that can be sourced by the VREFB circuit is 500 µA. The equation for setting the slowstart time is: tSLOWST = 5 × CSLOWST × RVREFB (seconds) Where RVREFB is the total external resistance from VREFB to ANAGND. power good The power-good circuit monitors for an undervoltage condition on VO. If VO is 7% below VREF, then the PWRGD pin is pulled low. PWRGD is an open-drain output. overvoltage protection The overvoltage protection (OVP) circuit monitors VO for an overvoltage condition. If VO is 15% above VREF, then a fault latch is set and both output drivers are turned off. The latch will remain set until VCC goes below the undervoltage lockout value. A 3-µs deglitch timer is included for noise immunity. Refer to the LODRV section for information on how to protect the microprocessor against overvoltages due to a shorted fault across the high-side power FET. POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 5 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 detailed description (continued) overcurrent protection The overcurrent protection (OCP) circuit monitors the current through the high-side FET. The overcurrent threshold is adjustable with an external resistor divider between IOUT and ANAGND, with the divider voltage connected to the OCP pin. If the voltage on OCP exceeds 100 mV, then a fault latch is set and the output drivers are turned off. The latch will remain set until VCC goes below the undervoltage lockout value. A 3-µs deglitch timer is included for noise immunity. The OCP circuit is also designed to protect the high-side power FET against a short-to-ground fault on the terminal common to both power FETs. drive regulator The drive regulator provides drive voltage to the output drivers. The minimum drive voltage is 7 V. The minimum short circuit current is 100 mA. Connect a 1-µF ceramic capacitor from DRV to DRVGND. LODRV The LODRV circuit is designed to protect the microprocessor against overvoltages that can occur if the high-side power FETs become shorted. External components to sense an overvoltage condition are required to use this feature. When an overvoltage fault occurs, the low-side FETs are used as a crowbar. LODRV is pulled low and the low-side FET will be turned on, overriding all control signals inside the TPS5210 controller. The crowbar action will short the input supply to ground through the faulted high-side FETs and the low-side FETs. A fuse in series with Vin should be added to disconnect the short-circuit. Table 1. Voltage Identification Codes VID TERMINALS (0 = GND, 1 = floating or pull-up to 5 V) VREF VID4 VID3 VID2 VID1 VID0 (Vdc) 0 1 1 1 1 1.30 0 1 1 1 0 1.35 0 1 1 0 1 1.40 0 1 1 0 0 1.45 0 1 0 1 1 1.50 0 1 0 1 0 1.55 0 1 0 0 1 1.60 0 1 0 0 0 1.65 0 0 1 1 1 1.70 0 0 1 1 0 1.75 0 0 1 0 1 1.80 0 0 1 0 0 1.85 0 0 0 1 1 1.90 0 0 0 1 0 1.95 0 0 0 0 1 2.00 0 0 0 0 0 2.05 1 1 1 1 1 No CPU 1 1 1 1 0 2.10 1 1 1 0 1 2.20 1 1 1 0 0 2.30 1 1 0 1 1 2.40 1 1 0 1 0 2.50 1 1 0 0 1 2.60 6 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 Table 1. Voltage Identification Codes (Continued) VID TERMINALS (0 = GND, 1 = floating or pull-up to 5 V) VREF VID4 VID3 VID2 VID1 VID0 (Vdc) 1 1 0 0 0 2.70 1 0 1 1 1 2.80 1 0 1 1 0 2.90 1 0 1 0 1 3.00 1 0 1 0 0 3.10 1 0 0 1 1 3.20 1 0 0 1 0 3.30 1 0 0 0 1 3.40 1 0 0 0 0 3.50 absolute maximum ratings over operating virtual junction temperature (unless otherwise noted)† Supply voltage range, VCC (see Note1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 14 V Input voltage range: BOOT to DRVGND (High-side Driver ON) . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 30 V BOOT to HIGHDRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 15 V BOOT to BOOTLO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 15 V INHIBIT, VIDx, LODRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7.3 V PWRGD, OCP, DROOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 7 V LOHIB, LOSENSE, IOUTLO, HISENSE . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 14 V VSENSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to 5 V Voltage difference between ANAGND and DRVGND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±0.5 V Output current, VREFB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5 mA Short circuit duration, DRV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Continuous Continuous total power dissipation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . See Dissipation Rating Table Operating virtual junction temperature range, TJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to 125°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –65°C to 150°C Lead temperature soldering 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTE 1: Unless otherwise specified, all voltages are with respect to ANAGND. DISSIPATION RATING TABLE PACKAGE TA ≤ 25°C POWER RATING DERATING FACTOR ABOVE TA = 25°C TA = 70°C POWER RATING TA = 85°C POWER RATING DW 1200 mW 12 mW/°C 660 mW 480 mW PWP 1150 mW 11.5 mW/°C 630 mW 460 mW POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 7 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 recommended operating conditions MIN MAX 11.4 13 V Input voltage, BOOT to DRVGND 0 28 V Input voltage, BOOT to BOOTLO 0 13 V Input voltage, INHIBIT, VIDx, LODRV, PWRGD, OCP, DROOP 0 6 V Input voltage, LOHIB, LOSENSE, IOUTLO, HISENSE 0 13 V Input voltage, VSENSE 0 4.5 V Voltage difference between ANAGND and DRVGND Output current, VREFB† 0 ±0.2 V 0 0.4 mA Supply voltage, VCC UNIT † Not recommended to load VREFB other than to set hystersis since IVREFB sets slowstart time. electrical characteristics over recommended operating virtual junction temperature range, VCC = 12 V, IDRV = 0 A (unless otherwise noted) reference/voltage identification PARAMETER TEST CONDITIONS VCC = 11.4 to 12.6 V, 1.3 V ≤ VREF ≤ 2.5 V VCC = 11.4 to 12.6 V, VREF = 2.6 V Reference voltage accuracy, (Includes offset of droop compensation network) VREF Cumulative reference accuracy (see Note 2) VIDx High-level input voltage VIDx Low-level input voltage VREFB VIDx MIN TYP MAX UNIT –0.01 0.01 V/V –0.0104 0.0104 V/V VCC = 11.4 to 12.6 V, VREF = 2.7 V VCC = 11.4 to 12.6 V, VREF = 2.8 V VCC = 11.4 to 12.6 V, VREF = 2.9 V –0.0108 0.0108 V/V –0.0112 0.0112 V/V –0.0116 0.0116 V/V VCC = 11.4 to 12.6 V, VREF = 3 V VCC = 11.4 to 12.6 V, VREF = 3.1 V VCC = 11.4 to 12.6 V, VREF = 3.2 V –0.0120 0.0120 V/V –0.0124 0.0124 V/V –0.0128 0.0128 V/V VCC = 11.4 to 12.6 V, VREF = 3.3 V VCC = 11.4 to 12.6 V, VREF = 3.4 V VCC = 11.4 to 12.6 V, VREF = 3.5 V –0.0132 0.0132 V/V –0.0136 0.0136 V/V –0.0140 0.0140 V/V –0.011 0.011 –0.008 0.008 VREF = 1.9 Vv, Hysteresis, TJ = 60°C window = 30 mV (see Note 3) –0.0090 0.0090 VREF = 3.5 V, Hysteresis, TJ = 60°C window = 30 mV (see Note 3) –0.0115 0.0115 VREF = 1.3 V, Hysteresis window = 30 mV VREF =1.3 V, Hysteresis, TJ = 60°C window = 30 mV (see Note 3) 2.25 V 1 Output voltage IVREFB = 50 µA Output regulation 10 µA ≤ IO ≤ 500 µA Input resistance VIDx = 0 V VREF–2% Input pull-up voltage divider V/V VREF VREF+2% 2 V V mV 36 73 95 kΩ 4.8 4.9 5 V NOTES: 2. Cumulative reference accuracy is the combined accuracy of the reference voltage and the input offset voltage of the hysteretic comparator. Cumulative accuracy equals the average of the high-level and low-level thresholds of the hysteretic comparator. 3. This parameter is ensured by design and is not production tested. 8 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 electrical characteristics over recommended operating virtual junction temperature range, VCC = 12 V, IDRV = 0 A (unless otherwise noted) (continued) power good PARAMETER TEST CONDITIONS Undervoltage trip threshold VOL IOH Low-level output voltage Vhys Hysteresis voltage MIN 90 IO = 5 mA VPWRGD = 6 V High-level input current TYP 93 0.5 MAX UNIT 95 %VREF V 0.75 µA 1 1.3 2.9 4.5 %VREF MIN TYP MAX UNIT 10.4 13 15.6 µA slowstart PARAMETER TEST CONDITIONS Charge current VSLOWST = 0.5 V, IVREFB = 65 µA Discharge current VSLOWST = 1 V VVREFB = 1.3 V, 3 Comparator input offset voltage Comparator input bias current mA 10 See Note 3 10 Comparator hysteresis –7.5 mV 100 nA 7.5 mV NOTE 3: This parameter is ensured by design and is not production tested. hysteretic comparator PARAMETER Input offset voltage Input bias current Hysteresis accuracy TEST CONDITIONS –2.5 VREFB – VHYST = 15 mV (Hysteresis window = 30 mV) –3.5 Maximum hysteresis setting VREFB – VHYST = 30 mV NOTE 3: This parameter is ensured by design and is not production tested. POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 MIN VDROOP = 0 V (see Note 3) See Note 3 • DALLAS, TEXAS 75265 TYP MAX 2.5 60 UNIT mV 500 nA 3.5 mV mV 9 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 electrical characteristics over recommended operating virtual junction temperature range, VCC = 12 V, IDRV = 0 A (unless otherwise noted) (continued) high-side VDS sensing PARAMETER TEST CONDITIONS MIN Gain Initial accuracy Sink current 5 V ≤ VIOUTLO ≤ 13 V IOUT Source current VIOUT = 0.5 V, VIOUTLO = 11.5 V IOUT Sink current VIOUT = 0.05 V, VHISENSE = 12 V, VIOUTLO = 12 V Output voltage swing VHISENSE = 11 V, RIOUT = 10 kΩ VHISENSE = 4.5 V, RIOUT = 10 kΩ VHISENSE = 3 V, RIOUT = 10 kΩ LOSENSE MAX 2 VHISENSE = 12 V, VLOSENSE = 11.9 V, Differential input to Vds sensing amp = 100 mV IOUTLO TYP High-level input voltage Low-level input voltage Sample/hold resistance VHISENSE = 12 V, 4 5 V (see Note 3) VHISENSE = 4.5 11.4 V ≤ VHISENSE ≤ 12.6 V, LOSENSE connected to HISENSE, VHISENSE – VIOUTLO = 0.15 V 4.5 V ≤ VHISENSE ≤ 5.5 V, LOSENSE connected to HISENSE, VHISENSE – VIOUTLO = 0.15 V 3 V ≤ VHISENSE ≤ 3.6 V, LOSENSE connected to HISENSE, VHISENSE – VIOUTLO = 0.15 V VHISENSE = 12.6 V to 3 V, CMRR VHISENSE – VOUTLO = 100 mV NOTE 3. This parameter is ensured by design and is not production tested. 194 UNIT V/V 206 mV 250 nA 500 µA 50 µA 0 2 V 0 1.5 V 0 0.75 V 2.85 V 2.4 V 50 60 80 62 85 123 67 95 144 69 75 MIN TYP MAX UNIT Ω dB inhibit PARAMETER TEST CONDITIONS Start threshold 1.9 2.1 2.35 V Hysteresis 0.08 0.1 0.12 V Stop threshold 1.85 V overvoltage protection PARAMETER TEST CONDITIONS Overvoltage trip threshold Hysteresis MIN TYP 112 115 See Note 3 10 MAX UNIT 120 %VREF mV NOTE 3: This parameter is ensured by design and is not production tested. overcurrent protection PARAMETER TEST CONDITIONS OCP trip threshold Input bias current 10 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 MIN TYP MAX 90 100 110 UNIT mV 100 nA TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 electrical characteristics over recommended operating virtual junction temperature range, VCC = 12 V, IDRV = 0 A (unless otherwise noted) (continued) deadtime PARAMETER LOHIB LOWDR TEST CONDITIONS High-level input voltage MIN TYP MAX 2.4 Low-level input voltage 1.4 High-level input voltage See Note 3 Low-level input voltage See Note 3 3 1.7 UNIT V V NOTE 3: This parameter is ensured by design and is not production tested. LODRV PARAMETER LODRV TEST CONDITIONS High-level input voltage MIN TYP MAX 1.85 Low-level input voltage 0.95 UNIT V droop compensation PARAMETER TEST CONDITIONS Initial accuracy VDROOP = 50 mV MIN TYP 46 MAX 54 UNIT mV drive regulator PARAMETER TEST CONDITIONS Output voltage 11.4 V ≤ VCC ≤ 12.6 V, Output regulation 1 mA ≤ IDRV ≤ 50 mA IDRV = 50 mA MIN TYP 7 MAX 9 100 Short-circuit current UNIT V mV 100 mA bias regulator PARAMETER Output voltage TEST CONDITIONS 11.4 V ≤ VCC ≤ 12.6 V, See Note 4 MIN TYP MAX 6 UNIT V NOTE 4: The bias regulator is designed to provide a quiet bias supply for the TPS5210 controller. External loads should not be driven by the bias regulator. input undervoltage lockout PARAMETER TEST CONDITIONS Start threshold MIN TYP MAX UNIT 9.25 10 10.75 V Hysteresis 1.9 2 2.2 V Stop threshold 7.5 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 V 11 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 electrical characteristics over recommended operating virtual junction temperature range, VCC = 12 V, IDRV = 0 A (unless otherwise noted) (continued) output drivers PARAMETER Peak output current (see Note 5) tpw < 100 µs, VBOOT – VBOOTLO = 6.5 V, High-side sink Duty cycle < 2%, TJ = 125°C, High-side source VHIGHDR = 1.5 V (source) or 6 V (sink), See Note 3 Low-side sink Duty Cycle < 2%, TJ = 125°C, Low-side source VLOWDR = 1.5 V (source) or 5 V (sink), See Note 3 High-side sink Output resistance (see Note 5) TEST CONDITIONS High-side source Low-side sink Low-side source tpw < 100 µs, VDRV = 6.5 V, MIN TYP MAX UNIT 2 2 A 2 2 3 TJ = 125°C,, VBOOT – VBOOTLO = 6.5 V,, VHIGHDR = 6 V (source) or 0.5 V (sink) 45 5.7 TJ = 125°C, VDRV = 6.5 V, VLOWDR = 6 V (source) or 0.5 V (sink) Ω 45 NOTES: 3. This parameter is ensured by design and is not production tested. 5. The pull-up/pull-down circuits of the drivers are bipolar and MOSFET transistors in parallel. The peak output current rating is the combined current from the bipolar and MOSFET transistors. The output resistance is the Rds(on) of the MOSFET transistor when the voltage on the driver output is less than the saturation voltage of the bipolar transistor. supply current PARAMETER VCC TEST CONDITIONS Supply voltage range VINHIBIT = 5 V, VCC > 10.75 V at startup, VCC Quiescent current High-side driver quiescent current VID code ≠ 11111, VBOOTLO = 0 V VINHIBIT = 5 V, VID code ≠ 11111, VCC > 10.75 V at startup, VBOOTLO = 0 V, CHIGHDR = 50 pF, CLOWDR = 50 pF, fSWX = 200 kHz, See Note 3 VINHIBIT = 0 V or VID code = 11111 or VCC < 9.25 V at startup, VBOOT = 13 V, VBOOTLO = 0 V VINHIBIT = 5 V, VID code ≠ 11111, VCC > 10.75 V at startup, VBOOT = 13 V, VBOOTLO = 0 V, CHIGHDR = 50 pF, fSWX = 200 kHz (see Note 3) NOTE 3: This parameter is ensured by design and is not production tested. 12 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 MIN TYP MAX 11.4 12 13 3 10 UNIT V mA 5 80 2 µA mA TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 switching characteristics over recommended operating virtual-junction temperature range, VCC = 12 V, IDRV = 0 A (unless otherwise noted) PARAMETER TEST CONDITIONS VSENSE to HIGHDR or LOWDR (excluding deadtime) Propagation Pro agation delay MIN 1.3 V ≤ VVREF ≤ 3.5 V, 10 mV overdrive (see Note 3) OCP comparator UNIT 150 250 ns 1 SLOWST comparator Overdrive = 10 mV (see Note 3) HIGHDR output CL = 9 nF, VBOOTLO = 0 V, VBOOT = 6.5 V, TJ = 125°C LOWDR output CL = 9 nF, TJ = 125°C VDRV = 6.5 V, HIGHDR output CL = 9 nF, VBOOTLO = 0 V, VBOOT = 6.5 V, TJ = 125°C LOWDR output CL = 9 nF, TJ = 125°C VDRV = 6.5 V, Rise time Fall time µs 1 PWRGD comparator Response time MAX 1 See Note 3 OVP comparator Deglitch time (Includes comparator propagation delay) TYP OCP 560 900 60 ns 60 60 ns 60 2 5 2 5 See Note 3 OVP High-side VDS sensing VHISENSE = 12 V, VIOUTLO pulsed from 12 V to 11.9 V, 100 ns rise/fall times (see Note 3) 2 VHISENSE = 4.5 V, VIOUTLO pulsed from 4.5 V to 4.4 V, 100 ns rise/fall times (see Note 3) 3 VHISENSE = 3 V, VIOUTLO pulsed from 3 V to 2.9 V, 100 ns rise/fall times (see Note 3) 3 Short-circuit protection rising-edge delay SCP LOSENSE = 0 V (see Note 3) Turn-on/turn-off delay VDS sensing sample/hold switch Crossover delay time ns µs µs 300 500 ns 3 V ≤ VHISENSE ≤ 11 V, VLOSENSE = VHISENSE (see Note 3) 30 100 ns LOWDR to HIGHDRV, and LOHIB to LOWDR See Note 3 30 100 ns Prefilter pole frequency Hysteretic comparator See Note 3 Propagation delay LODRV See Note 3 5 MHz 400 ns NOTE 3: This parameter is ensured by design and is not production tested. POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 13 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 TYPICAL CHARACTERISTICS SLOWSTART TIME vs SLOWSTART CAPACITANCE SLOWSTART TIME vs SUPPLY CURRENT (VREFB) 100 1000 V(VREFB) = 2 V I(VREFB) = 100 µA TJ = 25°C V(VREFB) = 2 V CS = 0.1 µF TJ = 25°C Slowstart Time – ms Slowstart Time – ms 10 1 100 10 0.1 0 0.0001 0.0010 0.0100 0.1000 1 1 1 10 Slowstart Capacitance – µF Figure 1 DRIVER DRIVER OUTPUT RISE TIME vs LOAD CAPACITANCE OUTPUT FALL TIME vs LOAD CAPACITANCE 1000 TJ = 25°C TJ = 25°C t f – Fall Time – ns t r – Rise Time – ns 1000 Figure 2 100 High Side Low Side 10 1 0.1 100 ICC – Supply Current (VREFB) – µA 1 10 100 100 High Side 1 0.1 CL – Load Capacitance – nF 1 10 CL – Load Capacitance – nF Figure 3 14 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 Low Side 10 Figure 4 • DALLAS, TEXAS 75265 100 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 TYPICAL CHARACTERISTICS OVP THRESHOLD vs JUNCTION TEMPERATURE OCP THRESHOLD VOLTAGE vs JUNCTION TEMPERATURE 118 105 OCP Threshold Voltage – mV OVP Threshold – % 117 116 115 114 113 112 0 25 50 75 100 103 101 99 97 95 125 0 25 TJ – Junction Temperature – °C Figure 5 75 100 125 Figure 6 INHIBIT START THRESHOLD VOLTAGE vs JUNCTION TEMPERATURE INHIBIT HYSTERESIS VOLTAGE vs JUNCTION TEMPERATURE 2.1 150 Inhibit Hysteresis Voltage – mV Inhibit Start Threshold Voltage – V 50 TJ – Junction Temperature – °C 2.05 2 1.95 1.9 0 25 50 75 100 125 125 100 75 50 0 TJ – Junction Temperature – °C 50 75 100 125 TJ – Junction Temperature – °C Figure 7 Figure 8 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 25 • DALLAS, TEXAS 75265 15 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 TYPICAL CHARACTERISTICS UVLO START THRESHOLD VOLTAGE vs JUNCTION TEMPERATURE UVLO HYSTERESIS vs JUNCTION TEMPERATURE 10.5 2.5 VI = 12 V 2.3 UVLO Hysteresis – V UVLO Start Threshold Voltage – V VI = 12 V 10 9.5 2.1 1.9 1.7 9 0 25 50 75 100 1.5 125 0 TJ – Junction Temperature – °C 25 50 75 100 125 TJ – Junction Temperature – °C Figure 9 Figure 10 QUIESCENT CURRENT vs JUNCTION TEMPERATURE POWERGOOD THRESHOLD vs JUNCTION TEMPERATURE 6 95 VI = 12 V Powergood Threshold – % Quiescent Current – mA 94 4 2 93 92 91 0 0 25 50 75 100 125 90 0 TJ – Junction Temperature – °C 50 75 100 TJ – Junction Temperature – °C Figure 11 16 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 25 Figure 12 • DALLAS, TEXAS 75265 125 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 TYPICAL CHARACTERISTICS DRIVER SLOW START CHARGE CURRENT vs JUNCTION TEMPERATURE REGULATOR VOLTAGE vs JUNCTION TEMPERATURE 15 8.5 14 8.25 Regulator Voltage – V Slow Start Charge Current – µ A V(VREFB) = 1.3 V R(VREFB) = 20 kΩ 13 12 8 7.75 11 10 0 25 50 75 100 7.5 125 0 TJ – Junction Temperature – °C 25 Figure 13 75 100 125 Figure 14 DRIVER DRIVER HIGH-SIDE OUTPUT RESISTANCE vs JUNCTION TEMPERATURE LOW-SIDE OUTPUT RESISTANCE vs JUNCTION TEMPERATURE 5 6 RO – Low-Side Output Resistance – Ω RO – High-Side Output Resistance – Ω 50 TJ – Junction Temperature – °C 4 3 2 1 0 4 2 0 0 25 50 75 100 125 0 TJ – Junction Temperature – °C 50 75 100 125 TJ – Junction Temperature – °C Figure 15 Figure 16 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 25 • DALLAS, TEXAS 75265 17 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 TYPICAL CHARACTERISTICS SENSING SAMPLE/HOLD RESISTANCE vs JUNCTION TEMPERATURE 100 RO – Sensing Sample/Hold Resistance – Ω V(HISENSE) = 12 V 75 50 25 0 0 25 50 75 100 TJ – Junction Temperature – °C Figure 17 18 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 125 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION The following figure is a typical application schematic. The circuit can be divided into the power-stage section and the control-circuit section. The power stage must be tailored to the input/output requirements of the application. The control circuit is basically the same for all applications with some minor tweaking of specific values. Table 2 shows the values of the power stage components for various output-current options. L101 L102 Q101 12V Vo R102 Q102 + C101 + C102 C105 C104 C103 R101 C106 GND RTN C2 1 uF RTN VSENSE LODRV LOHIB DRVGND BOOTLO LOSENSE HISENSE 12V Control Section HIGHDRV Power Stage C1 1 uF C3 1 uF 15 16 17 18 R1 3.40 k 1% 19 C6 0.033 uF 20 21 22 ENABLE 23 24 R4 2.55 k 1% C8 2200 pF 25 26 27 28 VCC DRV BOOT LOWDR HIGHDR DRVGND BOOTLO LOHIB HISENSE LODRV LOSENSE BIAS IOUTLO SLOWST INHIBIT ANAGND VID4 VSENSE VID3 VREFB VID2 VHYST VID1 OCP VID0 DROOP PWRGD IOUT 14 R2 150 13 12 C4 1 uF 11 C5 0.1 uF C7 10 9 8 7 6 1000 pF R5 100 5 4 3 R3 10.0 k R7 3.92 k R6 20.0 k R8 1.00 k R9 4.32 k R10 1.00 k 2 1 TPS5210 U1 Figure 18. Standard Application Schematic POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 19 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION Table 2. Power Stage Components Ref Des 12-V–Input Power Stage Components F nction Function 4–A Out 8–A Out 12–A Out 20–A Out 40–A Out C101 Input Bulk Capacitor Sanyo, 16SV100M, 100–uF, 16–V, 20% Sanyo, 16SA470M, 2 x 470–uF, 16–V, 20% Sanyo, 16SA470M, 2 x 470–uF, 16–V, 20% Sanyo, 16SA470M, 3 x 470–uF, 16–V, 20% Sanyo, 16SA470M, 4 x 470–uF, 16–V, 20% C102 Input Mid–Freq Capacitor muRata, GRM42–6Y5V105Z025A 1.0–uF, 25–V, +80%–20%, Y5V muRata, GRM42–6Y5V225Z016A 2.2–uF, 16–V, +80%–20%, Y5V muRata, GRM42–6Y5V225Z016A 2.2–uF, 16–V, +80%–20%, Y5V muRata, GRM42–6Y5V105Z025A 3 x 1.0–uF, 25–V, +80%–20%, Y5V muRata, GRM42–6Y5V105Z025A 4 x 1.0–uF, 25–V, +80%–20%, Y5V C103 Input Hi–Freq Bypass Capacitor muRata, GRM39X7R104K016A 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 2 x 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 3 x 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 4 x 0.1–uF, 16–V, X7R C104 Snubber Capacitor muRata, GRM39X7R102K050A, 1000–pF, 50–V, X7R muRata, GRM39X7R102K050A, 1000–pF, 50–V, X7R muRata, GRM39X7R102K050A, 2 x 1000–pF, 50–V, X7R muRata, GRM39X7R102K050A, 3 x 1000–pF, 50–V, X7R muRata, GRM39X7R102K050A, 4 x 1000–pF, 50–V, X7R C105 Output Bulk Capacitor Sanyo, 6TPB150M, 3 x 150–uF, 6.3–V, 20% Sanyo, 4SP820M, 820–uF, 4–V, 20% Sanyo, 4SP820M, 2 x 820–uF, 4–V, 20% Sanyo, 4SP820M, 3 x 820–uF, 4–V, 20% Sanyo, 4SP820M, 4 x 820–uF, 4–V, 20% C106 Output Hi–Freq Bypass Capacitor muRata, GRM39X7R104K016A, 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 2 x 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 3 x 0.1–uF, 16–V, X7R muRata, GRM39X7R104K016A, 4 x 0.1–uF, 16–V, X7R L101 Input Filter Inductor CoilCraft, DO1608C–332, 3.3–uH, 2.0–A Coiltronics, UP2B–2R2, 2.2–uH, 7.2–A Coiltronics, UP2B–2R2, 2.2–uH, 7.2–A Coiltronics, UP3B–1R0, 1–uH, 12.5–A Coiltronics, UP3B–1R0, 1–uH, 12.5–A L102 Output Filter Inductor CoilCraft, DO3316P–332, 3.3–uH, 6.1–A Coiltronics, UP3B–2R2, 2.2–uH, 9.2–A Coiltronics, UP4B–1R5, 1.5–uH, 13.4–A MicroMetals, T68–8/90 Core w/7T #16, 1.0–uH, 25–A Pulse Engineering, P1605, 1.0–uH, 50–A R101 Lo–Side Gate Resistor 3.3–Ohm, 1/16–W, 5% 3.3–Ohm, 1/16–W, 5% 2 x 3.3–Ohm, 1/16–W, 5% 3 x 3.3–Ohm, 1/16–W, 5% 4 x 3.3–Ohm, 1/16–W, 5% R102 Snubber Resistor 2.7–Ohm, 1/10–W, 5% 2.7–Ohm, 1/10–W, 5% 2 x 2.7–Ohm, 1/10–W, 5% 3 x 2.7–Ohm, 1/10–W, 5% 4 x 2.7–Ohm, 1/10–W, 5% Q101 Power Switch Siliconix, Si4410, NMOS, 13–mOhm Siliconix, Si4410, NMOS, 13–mOhm Siliconix, 2 x Si4410, NMOS, 13–mOhm Siliconix, 2 x Si4410, NMOS, 13–mOhm IR, 2 x IRF7811, NMOS, 11–mOhm Q102 Synchronous Switch Siliconix, Si4410, NMOS, 13–mOhm Siliconix, Si4410, NMOS, 13–mOhm Siliconix, 2 x Si4410, NMOS, 13–mOhm Siliconix, 3 x Si4410, NMOS, 13–mOhm IR, 4 x IRF7811, NMOS, 11–mOhm Nominal Frequency† 220 KHz 330 KHz 240 KHz 140 KHz 168 KHz Hysteresis Window 20 mV 20 mV 20 mV 20 mV 10 mV † Nominal frequency measured with Vo set to 2 V. The values listed above are recommendations based on actual test circuits. Many variations of the above are possible based upon the desires and/or requirements of the user. Performance of the circuit is equally, if not more, dependent upon the layout than on the specific components, as long as the device parameters are not exceeded. Fast-response, low-noise circuits require critical attention to the layout details. Even though the operating frequencies of typical power supplies are relatively low compared to today’s microprocessor circuits, the power levels and edge rates can cause severe problems both in the supply and the load. The power stage, having the highest current levels and greatest dv/dt rates, should be given the greatest attention. 20 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION frequency calculation A detailed derivation of frequency calculation is shown in the application report, “Designing Fast Response Synchronous Buck Regulators Using the TPS5210”, TI Literature number SLVA044. When less accurate results are acceptable, the simplified equation shown below can be used: fs ≅ ǒ ǒ ƪ* ƫ Ǔ VO VI L VI VO ESR Hysteresis Window Ǔ Control Section Below are the equations needed to select the various components within the control section. Details and the derivations of the equations used in this section are available in the application report “Designing Fast Response Synchronous Buck Regulators Using the TPS5210”, TI Literature number SLVA044. output voltage selection Of course the most important function of the power supply is to regulate the output voltage to a specific value. Values between 1.3 V and 3.5 V can be easily set by shorting the correct VID inputs to ground. Values above the maximum reference voltage (3.5 V) can be set by setting the reference voltage to any convenient voltage within its range and selecting values for R2 and R3 to give the correct output. Select R3: R3 << than VREF/IBIAS(VSENSE); a recommended value is 10 kΩ ǒ Ǔ Then, calculate R2 using: VO + VREF 1 ) R2 R3 or R2 + R3 ǒ VO Ǔ * VREF V REF R2 and R3 can also be used to make small adjusts to the output voltage within the reference-voltage range and/or to adjust for load-current active droop compensation. If there is no need to adjust the output voltage, R3 can be eliminated. R2, R3 (if used), and C7 are used as a noise filter; calculate using: C7 + ǒR2150ø nsR3Ǔ slowstart timing Slowstart reduces the startup stresses on the power-stage components and reduces the input current surge. Slowstart timing is a function of the reference-voltage current (determined by R6) and is independent of the reference voltage. The first step in setting slowstart timing will be to determine R6: R6 should be between 7 kΩ and 300 kΩ, a recommended value is 20 kΩ. Set the slowstart timing using the formula: C5 + ǒ5 t SS R VREFB Ǔ ≅ t SS (5 R6) Where C5 = Slowstart capacitance in µF tSS = Slowstart timing in µs RVREFB = Resistance from VREFB to GND in ohms (≈ R6) POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 21 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION hysteresis voltage A hysteretic controller regulates by self-oscillation, thus requiring a small ripple voltage on the output which the input comparator uses for sensing. Once selected, the TPS5210 hysteresis is proportional to the reference voltage; programming Vref to a new value automatically adjusts the hysteresis to be the same percentage of Vref. The actual output ripple voltage is the combination of the hysteresis voltage, overshoot caused by internal delays, and the output capacitor characteristics. Figure 20 shows the hysteresis window voltage (VHI to VLO) and the output voltage ripple (VMAX to VMIN). Since the output current from VREFB should be less than 500 µA, the total divider resistance (R5 + R6) should be greater than 7 KΩ. The hysteresis voltage should be no greater than 60 mV so R6 will dominate the divider. VREFB Hysteresis Window = 2 × VR5 R5 VHSYT R6 Figure 19. Hysteresis Divider Circuit VO VMAX VHI VREF VLO VMIN t Figure 20. Output Ripple The upper divider resistor, R5, is calculated using: R5 = Hysteresis Window V HYST (0 0 ) × R6 ≅ × R6 (2 × VREFB – Hysteresis Window ) (2 × 100 ) Where Hysteresis Window = the desired peak-to-peak hysteresis voltage. VREFB = selected reference voltage. VHYST (%) = [(Hysteresis Window)/VREFB] * 100 < VO(Ripple)(P–P) (%) 22 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION current limit Current limit can be implemented using the on-resistance of the upper FETs as the sensing elements. Select R8: R 8 << 0.1V V OCP ≤ ≤ 10 k Ω (100 × 100 nA ) I Bias (OCP ) (A recommended value is 1 kΩ) The IOUT signal is used to drive the current limit and droop-circuit dividers. The voltage at IOUT at the output current trip point will be: V IOUT (Trip ) = (2 × R DS(ON ) × TF ) NumFETs × I O(Trip ) Where NumFETS = Number of upper FETS in Parallel. TF = RDS(ON) temperature correction factor. IO(Trip) = Desired output current trip level (A). ǒ Calculate R7 using: R7 + V IOUT(Trip) 0.1 V Ǔ *1 R8 Note that since RDS(ON) of MOSFETs can vary from lot to lot and with temperature, tight current-limit control (less than 1.5 x IO) using this method is not practical. If tight control is required, an external current-sense resistor in series with the drain of the upper FET can be used with HISENSE and LOSENSE connected across the resistor. droop compensation Droop compensation is used to reduce the output voltage range during load transients by increasing the output voltage setpoint toward the upper tolerance limit during light loads and decreasing the voltage setpoint toward the lower tolerance limit during heavy loads. This allows the output voltage to swing a greater amount and still remain within the tolerance window. The maximum droop voltage is set with R9 and R10. Select R10: R10 << V DROOP ( Min ) I Bias ( DROOP ,Max ) ≤ 0.01V (100 × 100 nA) ≤ 1 kΩ (Again, a value of 1 kΩ is recommended) The voltage at IOUT during normal operation (0 to 100% load) will vary from 0 V up to: V IOUT ( Max ) = (2 × R DS(ON ) × TF ) NumFETs × I O( Max ) Where IO(Max) = Maximum output load current (A). POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 23 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION ǒ droop compensation (continued) Then, calculate R9: R9 + V IOUT(Max) V DROOP *1 Ǔ R10 Where VDROOP = Desired droop voltage ǒ ) Ǔ* At full load, the output voltage will be: VO + VREF R2 R3 1 V DROOP using the TPS5210 when both 12 V and 5 V are available When both 12 V and 5 V are available, several components can be removed from the basic schematic shown above. R1, R4, and C9 are no longer required if 5 V is brought in directly to INHIBIT and LODRV. However, if undervoltage lockout for the 5-V input is desired, R1 and R4 can be used to set the startup setpoint. The INHIBIT pin trip level is 2.1 V. Select R4: R 4 << V INH I INH ( Max ) 2.1V ≤ (100 × 100 nA ) ≤ 210 k Ω Then, set the 5-V UVLO trip level with R1: R1 = (5V Trip – 2V 2V ) × R4 LODRV R1 INHIBIT R4 Figure 21. 5-V Input with UVLO using the TPS5210 when only 5 V is available The TPS5210 controller requires 12 V for internal control of the device. If an external source for 12 V is not available, a small on-board source must be included in the design. Total 12-V current is very small, typically about 20 mA, so even a small charge pump can be used to generate the supply voltage. The power stage is not voltage dependent, but component values must be selected for 5-V inputs and the frequency of operation is dependent upon the power stage input voltage. 24 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION L101 L102 Q101 5V Vo R102 Q102 + C101 + C102 C105 C103 C106 C104 R101 GND RTN RTN VSENSE LODRV C2 LOHIB DRVGND BOOTLO HISENSE LOSENSE 5V HIGHDRV Power Stage Control Section 1 uF C1 0.1 uF 12 V 12-V Boost Circuit C3 1 uF 15 16 17 18 19 R1 10.0 k 1% C6 0.033 uF ENABLE 20 21 22 23 24 R4 11.0 k 1% C8 2200 pF 25 26 27 28 VCC DRV BOOT LOWDR HIGHDR DRVGND BOOTLO LOHIB HISENSE LODRV LOSENSE BIAS IOUTLO SLOWST INHIBIT ANAGND VID4 VSENSE VID3 VREFB VID2 VHYST VID1 OCP VID0 DROOP PWRGD IOUT 14 R2 150 13 12 C4 1 uF 11 C5 0.1 uF C7 10 9 8 7 6 1000 pF R5 100 5 4 3 R3 10.0 k R7 3.92 k R6 20.0 k R8 1.00 k R9 4.32 k R10 1.00 k 2 1 TPS5210 U1 Figure 22. Typical 5-V-Only Application Circuit application examples Various application and layout examples using the TPS5210 are available from Texas Instruments. This information can be downloaded from http://www.ti.com/sc/docs/products/msp/pwrsply/default.htm or received from your TI representative. POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 25 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 APPLICATION INFORMATION layout guidelines Good power supply results will only occur when care is given to proper design and layout. Layout will affect noise pickup and generation and can cause a good design to perform with less than expected results. With a range of currents from milliamps to tens or even hundreds of amps, good power supply layout is much more difficult than most general PCB design. The general design should proceed from the switching node to the output, then back to the driver section, and, finally, place the low-level components. Below are several specific points to consider before layout of a TPS5210 design begins. 1. All sensitive analog components should be referenced to ANAGND. These include components connected to SLOWST, DROOP, IOUT, OCP, VSENSE, VREFB, VHYST, BIAS, and LOHIB. 2. Analog ground and drive ground should be isolated as much as possible. Ideally, analog ground will connect to the ground side of the bulk storage capacitors on VO, and drive ground will connect to the main ground plane close to the source of the low-side FET. 3. Connections from the drivers to the gate of the power FETs, should be as short and wide as possible to reduce stray inductance. This becomes more critical if external gate resistors are not being used. 4. The bypass capacitor for the DRV regulator should be placed close to the TPS5210 and be connected to DRVGND. 5. The bypass capacitor for VCC should be placed close to the TPS5210 and be connected to DRVGND. 6. When configuring the high-side driver as a floating driver, the connection from BOOTLO to the power FETs should be as short and as wide as possible. The other pins that also connect to the power FETs, LOHIB and LOSENSE, should have a separate connection to the FETS since BOOTLO will have large peak currents flowing through it. 7. When configuring the high-side driver as a floating driver, the bootstrap capacitor (connected from BOOT to BOOTLO) should be placed close to the TPS5210. 8. When configuring the high-side driver as a ground-referenced driver, BOOTLO should be connected to DRVGND. 9. The bulk storage capacitors across VI should be placed close to the power FETS. High-frequency bypass capacitors should be placed in parallel with the bulk capacitors and connected close to the drain of the high-side FET and to the source of the low-side FET. 10. High-frequency bypass capacitors should be placed across the bulk storage capacitors on VO. 11. HISENSE and LOSENSE should be connected very close to the drain and source, respectively, of the high-side FET. HISENSE and LOSENSE should be routed very close to each other to minimize differential-mode noise coupling to these traces. Ceramic decoupling capacitors should be placed close to where HISENSE connects to Vin, to reduce high-frequency noise coupling on HISENSE. 26 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 MECHANICAL DATA DW (R-PDSO-G**) PLASTIC SMALL-OUTLINE PACKAGE 16 PIN SHOWN 0.050 (1,27) 0.020 (0,51) 0.014 (0,35) 16 0.010 (0,25) M 9 0.419 (10,65) 0.400 (10,15) 0.010 (0,25) NOM 0.299 (7,59) 0.293 (7,45) Gage Plane 0.010 (0,25) 1 8 0°– 8° A 0.050 (1,27) 0.016 (0,40) Seating Plane 0.104 (2,65) MAX 0.012 (0,30) 0.004 (0,10) PINS ** 0.004 (0,10) 16 20 24 28 A MAX 0.410 (10,41) 0.510 (12,95) 0.610 (15,49) 0.710 (18,03) A MIN 0.400 (10,16) 0.500 (12,70) 0.600 (15,24) 0.700 (17,78) DIM 4040000 / C 07/96 NOTES: A. B. C. D. All linear dimensions are in inches (millimeters). This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusion not to exceed 0.006 (0,15). Falls within JEDEC MS-013 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 27 TPS5210 PROGRAMMABLE SYNCHRONOUS BUCK REGULATOR CONTROLLER SLVS171A – SEPTEMBER 1998 – REVISED MAY 1999 MECHANICAL DATA PWP (R-PDSO-G**) PowerPAD PLASTIC SMALL-OUTLINE PACKAGE 20-PIN SHOWN 0,30 0,19 0,65 20 0,10 M 11 Thermal Pad (See Note D) 4,50 4,30 0,15 NOM 6,60 6,20 Gage Plane 1 10 0,25 A 0°– 8° 0,75 0,50 Seating Plane 0,15 0,05 1,20 MAX PINS ** 0,10 14 16 20 24 28 A MAX 5,10 5,10 6,60 7,90 9,80 A MIN 4,90 4,90 6,40 7,70 9,60 DIM 4073225/E 03/97 NOTES: A. B. C. D. All linear dimensions are in millimeters. This drawing is subject to change without notice. Body dimensions do not include mold flash or protrusions. The package thermal performance may be enhanced by bonding the thermal pad to an external thermal plane. This pad is electrically and thermally connected to the backside of the die and possibly selected leads. E. Falls within JEDEC MO-153 PowerPAD is a trademark of Texas Instruments Incorporated. 28 POST OFFICE BOX 655303 Powered by ICminer.com Electronic-Library Service CopyRight 2003 • DALLAS, TEXAS 75265 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER’S RISK. In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI’s publication of information regarding any third party’s products or services does not constitute TI’s approval, warranty or endorsement thereof. Copyright 1999, Texas Instruments Incorporated Powered by ICminer.com Electronic-Library Service CopyRight 2003