ETC 130659-E

BTR
TELECOM
Test Device for
ISDN Installations
SiTi
Quick and easy testing
with four LEDs
P/N 130 659-E
User Manual SiTi
The SiTi is a simple device for testing the
installation of an ISDN-S0-connection.
Checking of the installation is done by
plugging the SiTi into the RJ45 jack. The
terminating resistors should not yet be
mounted.
The four LEDs of the SiTi show the wiring
diagram of the four terminating wires for
the ISDN-installation.
terminal
number
SiTi
4
5
3
6
1a
1b
2a
2b
wire
number
Error Detection SiTi
When testing the wall outlets the LEDs on the
SiTi will light as follows:
all LEDs
light green
all wires are connected
correctly
all LEDs
light red
all wires have been
misconnected
all LEDs
are off
short circuit on the wire pairs
or interruption on at least two
wires of a pair
one or several interruption of such wire of
which the related LED is off
LEDs are off
one or several misconnection of such
LEDs light red wire of which the related
LED lights red
By combining those four LEDs with their
different conditions green, red and off, the
SiTi can show more than 40 different wiring
conditions. The following chart shows
some examples.
LED auf dem SiTi
1a
(4)
off
1b
(5)
2a
(3)
Error
green green green wire 1a is interrupted
green green off
red
2b
(6)
green wire 2a is interrupted
green green red
wire 1a has been
reversed with wire 2b
wire1b has been
reversed with wire 2b
green red
green red
green red
off
green wire 1b interrupted,
red
red
red
1. Check of the NTBA Connection
First the ISDN connection at the NTBA is
checked at normal and at emergency
operation.
Normal mode means that the NTBA is
connected to the 230 V mains.
Emergency mode means that the NTBA is
not connected to the 230 V mains and the
installation is supplied by the Telecom
power supply.
When the SiTi is plugged into the jacks of
the NTBA, the four LEDs light green when
the NTBA is working in normal operation, if
it is running in the emergency mode all
LEDs light red, provided that the NTBA and
the attachment are working correctly.
red
wire 2a connected to
terminal 5 instead of
terminal 3
all wires are
misconnected or
the NTBA is running
in emergency mode
Note:
The SiTi is not meant for steady
operation. Use it only for testing.
2. Check of the Wall Outlet Installation
The NTBA has to run in normal operation
and the terminating resistors should not be
mounted when the wall outlet installation
is tested. The SiTi is plugged in one jack
after another (see error chart on the back).
BTR
Blumberger
Telefon- und Relaisbau
Albert Metz e. K.
Im Tal 2
D-78176 Blumberg
phone +49 7702/533-0
fax
+49 7702/533-433
[email protected]
www.ria-btr.de
Subject to technical change.
4. Test Completion
After completing all tests the terminating
resistors are mounted and the ISDN
installation can be put into operation.
Designed and manufactured by:
1298/100/01/MAMS/899805-01
3. Enhanced Check for S0-Bus Installation
If more than one ISDN device is to run at
one ISDN installation it is important that
wires 2a and 2b are not reversed when
terminated.
In order to exclude reversal of these two
wires, wire 2a is interrupted at the first
possibility of the ISDN installation. Now
the SiTi should show at each wall outlet
the interruption of wire 2a.
If it is showing interruption of wire 2b
this proves that wire 2a and 2b have been
reversed.
When all reversals have been detected and
corrected, wire 2a can be reterminated.