Bulletin I2157 rev. A 08/02 SAFEIR Series 25ETS.. INPUT RECTIFIER DIODE Description/Features The 25ETS.. rectifier SAFEIR series has been optimized for very low forward voltage drop, with moderate leakage. The glass passivation technology used has reliable operation up to 150°C junction temperature. VF < 1V @ 10A IFSM = 300A VRRM 800 to 1200V Typical applications are in input rectification and these products are designed to be used with International Rectifier Switches and Output Rectifiers which are available in identical package outlines. Output Current in Typical Applications Single-phase Bridge Capacitive input filter TA = 55°C, TJ = 125°C, common heatsink of 1°C/W Units IF(AV) Sinusoidal 25 A VRRM Range (*) 800 to 1200 V 300 A 1.0 V - 40 to 150 °C IFSM VF @ 10 A, TJ = 25°C TJ (*) for higher voltage up to 1600V contact factory www.irf.com 23 A Package Outline 25ETS.. waveform Units 20 Major Ratings and Characteristics Characteristics Three-phase Bridge TO-220AC Also available in SMD-220 package (series 25ETS..S) 1 25ETS.. SAFEIR Series Bulletin I2157 rev. A 08/02 Voltage Ratings VRRM, maximum VRSM , maximum non repetitive IRRM peak reverse voltage V peak reverse voltage V 150°C mA 25ETS08 800 900 1 25ETS12 1200 1300 Part Number Provide terminal coating for voltages above 1200V Absolute Maximum Ratings Parameters IF(AV) Max. Average Forward Current IFSM I2t 25ETS.. Units 25 A Max. Peak One Cycle Non-Repetitive 250 Surge Current 300 Max. I2t for fusing 316 442 2 I √t 2 Max. I √t for fusing A A2s 2 4420 A √s Conditions @ TC = 106° C, 180° conduction half sine wave 10ms Sine pulse, rated VRRM applied 10ms Sine pulse, no voltage reapplied 10ms Sine pulse, rated VRRM applied 10ms Sine pulse, no voltage reapplied t = 0.1 to 10ms, no voltage reapplied Electrical Specifications Parameters 25ETS.. Units VFM Max. Forward Voltage Drop 1.14 V rt Forward slope resistance 9.62 mΩ VF(TO) Threshold voltage 0.87 V IRM 0.1 Max. Reverse Leakage Current mA 1.0 Conditions @ 25A, TJ = 25°C TJ = 150°C TJ = 25 °C TJ = 150 °C VR = rated VRRM Thermal-Mechanical Specifications Parameters 25ETS.. Units TJ Max. Junction Temperature Range - 40 to 150 °C Tstg Max. Storage Temperature Range - 40 to 150 °C RthJC Max. Thermal Resistance Junction 0.9 °C/W to Case Max. Thermal Resistance Junction 62 °C/W 0.5 °C/W RthJA Conditions DC operation to Ambient RthCS Typ. Thermal Resistance Case to Heatsink wt Approximate Weight T Mounting Torque Case Style 2 2 (0.07) g (oz.) Min. 6 (5) Max. 12 (10) Kg-cm (Ibf-in) Mounting surface, smooth and greased TO-220AC www.irf.com 25ETS.. SAFEIR Series 150 25ETS..S Series R thJC (DC) = 0.9 K/W 140 130 Conduction Angle 120 110 30˚ 100 60˚ 90˚ 120˚ 90 180˚ 80 0 5 10 15 20 25 30 Maximum Allowable Case Temperature (°C) Maximum Allowable Case Temperature (°C) Bulletin I2157 rev.A 08/02 150 25ETS.. Series R thJC (DC) = 0.9 K/W 140 130 Conduction Period 120 110 30˚ 0 5 RMS Limit 20 Conduction Angle 15 10 25ETS.. Series Tj = 150˚C 5 0 0 5 10 15 20 25 30 60 40 30 RMS Limit 20 Conduction Period 10 25ETS.. Series Tj = 150˚C 0 0 250 200 150 100 25ETS.. Series 50 1 10 100 Number Of Equal Amplitude Half Cycle Current Pulsed (N) Fig. 5 - Maximum Non-Repetitive Surge Current www.irf.com 10 20 30 40 Average Forward Current (A) Fig. 4 - Forward Power Loss Characteristics Peak Half Sine Wave Forward Current (A) Peak Half Sine Wave Forward Current (A) At Any Rated Load Condition And With Rated Vrrm Applied Following Surge. Initial Tj = 150˚C @ 60 Hz 0.0083 s @ 50 Hz 0.0100 s DC 180˚ 120˚ 90˚ 60˚ 30˚ 50 Average Forward Current (A) Fig. 3 - Forward Power Loss Characteristics 300 10 15 20 25 30 35 40 Fig. 2 - Current Rating Characteristics Maximum Average Forward Power Loss (W) Maximum Average Forward Power Loss (W) 25 DC Average Forward Current (A) 180˚ 120˚ 90˚ 60˚ 30˚ 30 180˚ 90 Fig. 1 - Current Rating Characteristics 35 90˚ 120˚ Average Forward Current (A) 40 60˚ 100 300 200 Maximum Non Repetitive Surge Current Versus Pulse Train Duration. Initial Tj = 150˚C J No Voltage Reapplied Rated Vrrm Reapplied 100 25ETS.. Series 0 0.01 0.1 1 10 Pulse Train Duration (s) Fig. 6 - Maximum Non-Repetitive Surge Current 3 25ETS.. SAFEIR Series Bulletin I2157 rev. A 08/02 1000 Instantaneous Forward Current (A) TJ = 25˚C 100 TJ = 150˚C 10 25ETS.. Series 1 0 1 2 3 4 5 Instantaneous Forward Voltage (V) Fig. 7 - Forward Voltage Drop Characteristics Transient Thermal Impedance Z thJC (˚C/ W) 1 D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08 Steady State Value (DC Operation) Single Pulse 0.1 25ETS. .Series 0.01 0.0001 0.001 0.01 0.1 1 10 100 Square Wave Pulse Duration (s) Fig. 8 - Thermal Impedance ZthJC Characteristics 4 www.irf.com 25ETS.. SAFEIR Series Bulletin I2157 rev.A 08/02 Outline Table 10.54 (0.41) 2 MAX. 1.32 (0.05) 3.78 (0.15) 3.54 (0.14) 6.48 (0.25) 6.23 (0.24) 2.92 (0.11) 15.24 (0.60) 1.22 (0.05) DIA. 2.54 (0.10) TERM 2 14.84 (0.58) 2° 1 2 3 14.09 (0.55) 3.96 (0.16) 13.47 (0.53) 3.55 (0.14) 0.10 (0.004) 2.04 (0.080) MAX. 1.40 (0.05) 2.89 (0.11) 1.15 (0.04) 2.84 (0.10) 0.94 (0.04) 0.69 (0.03) 1 2 3 4.57 (0.18) 0.61 (0.02) MAX. 4.32 (0.17) 5.08 (0.20) REF. Dimensions in millimeters and (inches) Marking Information EXAMPLE: THIS IS A 25ETS12 LOT CODE 1789 ASSEMBLED ON WW 19, 2000 IN THE ASSEMBLY LINE "C" www.irf.com INTERNATIONAL RECTIFIER LOGO ASSEMBLY LOT CODE PART NUMBER DATE CODE YEAR = 2000 WEEK 19 LINE C 5 25ETS.. SAFEIR Series Bulletin I2157 rev. A 08/02 Ordering Information Table Device Code 25 E T S 12 1 2 3 4 5 BASE + 2 (K) 3 (A) 1 (A) - 1 - Current Rating 2 - Circuit Configuration: 3 - Package: 4 - Type of Silicon: - E = Single Diode T = TO-220AC S = Standard Recovery Rectifier 5 - Voltage code: Code x 100 = VRRM 08 = 800V 12 = 1200V (*) for higher voltage up to 1600V contact factory Data and specifications subject to change without notice. This product has been designed and qualified for Industrial Level. Qualification Standards can be found on IR's Web site. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 08/02 6 www.irf.com