ETC B64G-NNK-AD3-RMN

B64G
Olympian Plus
Filter/Regulator
1/4", 3/8", 1/2", 3/4" Port Sizes
● Olympian Plus plug in design
● High Efficiency water and particle removal
● Quick release bayonet bowl
● High visibility prismatic sight glass*
● Push to lock adjusting knob with tamper resistant
option
* UK and other patents pending
Technical Data
Fluid: Compressed air
Maximum pressure:
Guarded transparent bowl: 10 bar (145 psig)
Metal bowl: 17 bar (250 psig)
Operating temperature*:
Guarded transparent bowl: -20° to +50°C (0° to +125°F)
Metal bowl: -20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice formation at temperatures below 2°C
(35°F).
Partical removal: 5, 25 or 40 µm. Within ISO 8573-1, Class 3 and
Class 5
Typical flow at 6,3 bar (90 psig) inlet pressure†:
110 dm3/s (233 scfm)
Automatic drain connection: ISO G1/8
Automatic drain operating conditions:
Drain closes when bowl pressure exceeds 0,7 bar (10 psig)
and opens when bowl pressure drops below 0,07 bar (1 psig).
Gauge Ports: ISO Rc 1/8
Nominal bowl size:
0,2 litre (7 ounce)
Materials:
Body: Zinc
Bonnet: Aluminium
Valve: Brass
Yoke: Zinc
Metal bowl: Aluminium
Standard metal bowl prismatic liquid level indicator lens:
Grilamid
Optional metal bowl sight glass: Pyrex
Optional transparent bowl: Polycarbonate
Element: Sintered plastic
Elastomers: Synthetic rubber
1/97
Ordering Information
See Ordering Information on the following
pages.
ISO Symbols
Automatic Drain
Relieving
Manual Drain
Relieving
Automatic Drain
Non-relieving
Manual Drain
Non-relieving
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
N/AL.8.240.300.01
B64G
Typical Performance Characteristics
bar g
psig
FLOW CHARACTERISTICS
PORT SIZE: 1/2"
40 µm ELEMENT
INLET PRESSURE: 10 bar (145 psig)
RANGE: 0,3 to 10 bar (5 to 145 psig)
8
OUTLET PRESSURE
100
6
80
60
4
40
2
20
0
0
0
0
20
40
40
80
60
120
80
160
100
200
dm3/s
240 scfm
AIR FLOW
Ordering Information. Models listed include ISO G threads, knob adjustment, automatic drain, metal bowl, 40 µm element, relieving
diaphragm and 0,3 to 10 bar (5 to 145 psig) outlet pressure adjustment range* without gauge.
Port Size
G1/4
G3/8
G1/2
G3/4
Model
B64G-2GK-AD3-RMN
B64G-3GK-AD3-RMN
B64G-4GK-AD3-RMN
B64G-6GK-AD3-RMN
Flow† dm3/s (scfm)
30 (64)
76 (161)
106 (225)
N.A.
Weight kg (lb)
1,71 (3.80)
1,69 (3.76)
1,66 (3.69)
2,02 (4.49)
† Typical flow with 10 bar (145 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (15 psig) droop from set.
Alternative Models
B 6 4 G - ★ ★ ★ - ★★ ★ - ★★ ★
*
**
Port Size
1/4"
3/8"
1/2"
3/4"
Substitute
2
3
4
6
Threads
PTF
ISO Rc taper
ISO G parallel
Substitute
A
B
G
Adjustment
Knob
T-bar
Substitute
K
T
Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
Units with 17 bar (250 psig) adjustment
range are available only with the T-bar
adjustment; therefore substitute T at the 7th
digit and S at the 12th position.
N/AL.8.240.300.02
Gauge
With
Without
Substitute
G
N
Outlet Pressure Adjustment Range*
0,3 to 4 bar (5 to 60 psig)
0,3 to 10 bar (5 to 145 psig)
2 to 17 bar (29 to 250 psig)
Substitute
F
M
S**
Diaphragm
Relieving
Non relieving
Substitute
R
N
Element
5 µm
25 µm
40 µm
Substitute
1
2
3
Bowl
Metal with liquid level indicator
Guarded Transparent
Substitute
D
P
Drain
1/4 turn manual
Automatic
Substitute
M
A
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
1/97
B64G
Accessories
Wall Mounting Bracket
Tamper Resistant Kit
74504-50
4355-50
Seal Wire: 2117-01
Ø 50 mm
Pressure Gauge
R1/8 Connection
6 bar (60 psig):
10 bar (150 psig):
25 bar (360 psig):
18-013-012
18-013-013
18-013-014
1/8 PTF Connection
—
18-013-209
18-013-210
Dimensions mm (inches)
Panel mounting hole diameter: 52 mm (2.06")
B64G (automatic drain)
294 (11.6)*
310 (12.2)†
303 (11.9)†
287 (11.3)*
125 (2.92)*
125 (2.92)*
Panel thickness: 0 to 6 mm (0" to 0.25")
B64G (manual drain)
*
74 (2.91)
37 (1.46)
105 (4.13)**
Reduces by 4 mm (0.16") with knob in locked
position. Add 37 mm (1.46”) for unit with ‘T’ handle
† Minimum clearance required to remove bowl.
** 157 mm (6.18”) for G3/4 models
1/97
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
N/AL.8.240.300.03
B64G
Bracket Kit Reference
Bracket Mounting
Item
Wall Bracket
Part Number
74504-50
114 (4.49)
11 (0.43)
110 (4.33)
30,5 (1.20)
143 (5.63)
93 (3.66)
8,2 (0.32)
Use 8 mm (5/16") screws to mount bracket to wall.
85 (3.35)
48 (1.89)
14,5 (0.57)
Service Kits
Item
Service kit
Replacement elements
Replacement Sight Glass
Replacement Drains
Type
Relieving
Non relieving
5 µm
25 µm
40 µm
Prismatic (standard)
Pyrex
Automatic
Manual
Part Number
4383-200
4383-201
4338-01
4338-99
4338-02
4380-040
4380-041
3000-97
684-84
Service kit includes diaphragm assembly, valve assembly,
valve spring, louvre o-ring, bowl o-ring, drain seal.
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
N/AL.8.240.300.04
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
1/97