ETC B72G-3GK-ST3-RMN

B72G
EXCELON®72
General Purpose Filter/Regulator
1/4", 3/8" Port Sizes
● EXCELON design allows in-line installation or
modular installation with other Excelon 72 products
● High efficiency water and particle removal
● Quick release bayonet bowl
● Patented quarter turn manual drain
● Highly visible, prismatic liquid level indicator lens on
metal bowls
● Full flow gauge ports
● Balanced valve design for optimum pressure control
● Push to lock adjusting knob with tamper resistant
accessory
Technical Data
Fluid: Compressed air
Maximum pressure:
Transparent bowl:
10 bar (145 psig)
Metal bowl:
With manual or semi automatic drain: 17 bar (250 psig)
With automatic drain: 8 bar (116 psig)
Operating temperature*:
Transparent bowl: -20° to +50°C (0° to +125°F)
Metal bowl: -20° to +65°C (0° to +150°F)
* Air supply must be dry enough to avoid ice formation at temperatures below 2°C (35°F).
Partical removal: 5 µm, 25 µm or 40 µm. Within ISO 8573-1, Class
3 and Class 5
Typical flow at 10 bar (145 psig) inlet pressure, 6,3 bar
(90 psig) set pressure and a droop of 1 bar (15 psig) from set:
38 dm3/s (80 scfm)
Manual drain thread: 7/16-24 UNS male for 1/4" tube nut and
ferrule
Semi automatic drain connection: 8 mm (5/16") ID tube
Semi automatic drain operating pressure:
Drain closes when bowl pressure exceeds 0,1 bar (1.5 psig)
and opens when bowl pressure drops below 0,1 bar (1.5 psig).
Can be operated manually by lifting the stem.
Automatic drain connection: ISO R1/8
Automatic drain operating conditions:
Minimum flow to close drain: 0,14 dm3/s (0.3 scfm)
Drain closes when bowl pressure exceeds 0,7 bar (10 psig)
and opens when bowl pressure drops below 0,07 bar (1 psig).
Gauge ports:
1/8" PTF with PTF main ports
1/8" ISO Rc with ISO Rc main ports
1/8" ISO Rc with ISO G main ports
Nominal bowl size:
Short bowl: 56 ml (1.9 ounce)
Long bowl: 65 ml (2.2 ounce)
1/97
Materials:
Body: Zinc
Bonnet: Acetal
Valve: Brass
Bowl:
Transparent: Polycarbonate
Metal: Zinc
Metal bowl liquid level indicator lens:
Transparent nylon
Element: Sintered polypropylene
Elastomers: Neoprene and nitrile
Ordering Information
See Ordering Information on the following
pages.
ISO Symbols
Automatic and
Semi Automatic Drain
Relieving
Manual Drain
Relieving
Automatic and
Semi Automatic Drain
Non Relieving
Manual Drain
Non Relieving
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
N/AL.8.160.300.01
B72G
Typical Performance Characteristics
PORT SIZE: 1/4"
ELEMENT: 40 µm
INLET PRESSURE: 7 bar g (100 psig)
RANGE: 0,3 to 10 bar (5 to 145 psig)
12
OUTLET PRESSURE
OUTLET PRESSURE
150
9
120
6
60
9
120
90
6
60
3
3
30
0
PORT SIZE: 1/4"
ELEMENT: 40 µm
INLET PRESSURE: 10 bar g (145 psig)
RANGE: 0,3 to 10 bar (5 to 145 psig)
12
150
90
bar g
FLOW CHARACTERISTICS
psig
bar g
psig
FLOW CHARACTERISTICS
30
0
0
0
5
0
10
10
20
15
30
20
40
25
50
0
dm3/s
0
60 scfm
0
10
20
20
30
40
60
AIR FLOW
40
80
dm3/s
50
100
120 scfm
AIR FLOW
Ordering Information. Models listed include BSP threads, knob adjustment, semi automatic drain, transparent bowl without guard,
40 µm element, relieving diaphragm, 0,3 to 10 bar (5 to 145 psig) outlet pressure adjustment range* without gauge.
Port Size
G1/4
G3/8
Model
B72G-2GK-ST3-RMN
B72G-3GK-ST3-RMN
Flow† dm3/s (scfm)
38 (80)
38 (80)
Weight kg (lb)
0,52 (1.15)
0,52 (1.15)
† Typical flow with 10 bar (145 psig) inlet pressure, 6,3 bar (90 psig) set pressure and a 1 bar (15 psig) droop from set.
Alternative Models
B 7 2 G - ★ ★ ★ - ★★ ★ - ★★ ★
*
†
Port Size
1/4"
3/8"
Substitute
2
3
Gauge
With
Without
Substitute
G
N
Threads
PTF
ISO Rc taper
ISO G parallel
Substitute
A
B
G
Outlet Pressure Adjustment Range*
0,3 to 2 bar (5 to 30 psig)
0,3 to 4 bar (5 to 60 psig)
0,3 to 10 bar (5 to 145 psig)
Substitute
C
F
M
Adjustment
Knob
T-bar
Substitute
K
T
Diaphragm
Relieving
Non relieving
Substitute
R
N
Element
5 µm
25 µm
40 µm
Substitute
1
2
3
Bowl
Metal with liquid level indicator
Transparent without guard
Long transparent without guard
Substitute
D
T
L
Drain
1/4 turn manual
Semi automatic
Auto drain†
Substitute
Q
S
A
Outlet pressure can be adjusted to
pressures in excess of, and less than,
those specified. Do not use these units to
control pressures outside of the specified
ranges.
Supplied in long bowl options only
N/AL.8.160.300.02
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
1/97
B72G
Accessories
Wall Mounting Bracket
4224-50
Neck Mounting Bracket
74316-50
Includes plastic panel nut
Pressure Gauge
Ø 40 mm
R1/8 Connection
4 bar (60 psig):
10 bar (150 psig):
25 bar (360 psig):
18-013-990
18-013-989
18-013-908
Panel Nut
1/8 PTF Connection
18-013-211
18-013-212
Plastic: 4248-89
Tamper Resistant
Cover and Seal wire
4255-51
Seal Wire: 2117-01
Dimensions mm (inches)
Panel mounting hole diameter: 40 mm (1.57")
Transparent Bowl
134 (5.27) *
26 (1.01)
Transparent Bowl
with Automatic Drain
185 (7.27)†
146 (5.75)
197 (7.76)
134 (5.27) *
73 (2.89)
26 (1.01)
*
185 (7.27)†
134 (5.27) *
185 (7.27)†
Metal Bowl
35 (1.38) 48 (1.89)
63 (2.48)
35 (1.38) 48 (1.89)
50 (1.97)
95 (3.73)
Panel thickness: 0 to 4 mm (0" to 0.16")
Transparent Bowl with T-bar
For semi automatic drain add 30 mm (1.17") to 1/4 turn manual
drain shown.
† Minimum clearance required to remove bowl. For semi automatic
drain add 30 mm (1.17") to 1/4 turn manual drain shown.
1/97
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
N/AL.8.160.300.03
B72G
Bracket Mounting
Wall Bracket
Use 4 mm (5/32") screws to mount bracket to wall.
Quikclamp and Quikclamp Wall Bracket
Use 5 mm (3/16") screws to mount bracket to wall.
42 (1.65)
20 (0.80)
38 (1.50)
Port CL
59 (2.32)
74 (2.91)
60 (2.36)
38(1.50)
Port C
L
12 (0.47)
51 (2.00)
18.6 (0.73)
Port C
L
39 (1.54)
5 (0.20)
6 (0.24)
4 (0.16)
14 (0.55)
Neck Mounting for B72, R72, V72, includes plastic panel nut
Use 4 mm (5/32") screws to mount bracket to wall.
38 (1.50)
49 (1.93)
Bracket Kit Reference
Item
Wall bracket
Neck mounting wall bracket
Quikclamp and Quikclamp wall bracket
Part Number
4224-50
74316-50
4214-52
34 (1.34)
Port CL
30 (1.18)
7 (0.28)
4,4 (0.17)
Port CL
Service Kits
Item
Service kit
Replacement elements
Liquid level lens kit
Replacement drains
Type
Relieving
Non relieving
5 µm
25 µm
40 µm
Prismatic
1/4 turn manual
Semi automatic
Automatic
Part Number
4383-500
4383-501
5925-03
5925-01
5925-02
4380-030
619-50
5379-RK
4000-50R
Service kit includes diaphragm assembly, valve assembly,
valve spring, louvre o-ring, bowl o-ring, drain seal.
N/AL.8.160.300.04
Warning
These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under ‘Technical Data’.
Before using these products with fluids other than those specified, for
non-industrial applications, life-support systems, or other applications not
within published specifications, consult NORGREN.
Through misuse, age, or malfunction, components used in fluid
power systems can fail in various modes. The system designer is warned
to consider the failure modes of all component parts used in fluid power
systems and to provide adequate safeguards to prevent personal injury or
damage to equipment in the event of such failure.
System designers must provide a warning to end users in the
system instructional manual if protection against a failure mode
cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with these
products.
Water vapor will pass through these units and will condense into
liquid if air temperature drops in the downstream system. Install an air
dryer if water condensation could have a detrimental effect on the
application.
Our policy is one of continuous research and development.
We reserve the right to amend, without notice, the specifications given in this document.
1/97