Direct RDRAM™ 72-Mbit (256Kx16/18x16d) ® RAMBUS Overview The Rambus Direct RDRAM™ is a general purpose high-performance memory device suitable for use in a broad range of applications including computer memory, graphics, video, and any other application where high bandwidth and low latency are required. The 72-Mbit Direct Rambus DRAMs (RDRAM) are extremely high-speed CMOS DRAMs organized as 4M words by 18 bits. The use of Rambus Signaling Level (RSL) technology permits 600MHz to 800MHz transfer rates while using conventional system and board design technologies. Direct RDRAM devices are capable of sustained data transfers at 1.25 ns per two bytes (10ns per sixteen bytes). The architecture of the Direct RDRAMs allows the highest sustained bandwidth for multiple, simultaneous randomly addressed memory transactions. The separate control and data buses with independent row and column control yield over 95% bus efficiency. The Direct RDRAM's sixteen banks support up to four simultaneous transactions. System oriented features for mobile, graphics and large memory systems include power management, byte masking, and x18 organization. The two data bits in the x18 organization are general and can be used for additional storage and bandwidth or for error correction. Features ■ Highest sustained bandwidth per DRAM device - 1.6GB/s sustained data transfer rate - Separate control and data buses for maximized efficiency - Separate row and column control buses for easy scheduling and highest performance - 16 banks: four transactions can take place simultaneously at full bandwidth data rates ■ Low latency features - Write buffer to reduce read latency - 3 precharge mechanisms for controller flexibility - Interleaved transactions ■ Advanced power management: - Multiple low power states allows flexibility in power consumption versus time to transition to active state - Power-down self-refresh ■ Organization: 1Kbyte pages and 16 banks, x 18 - x18 organization allows ECC configurations or increased storage/bandwidth ■ Uses Rambus Signaling Level (RSL) for up to 800MHz operation INFINEON Technologies Version 1.0 Figure 1: Direct RDRAM CSP Package The 72-Mbit Direct RDRAMs are offered in a CSP horizontal package suitable for desktop as well as lowprofile add-in card and mobile applications. Direct RDRAMs operate from a 2.5 volt supply. Key Timing Parameters/Part Number Organization I/O Freq. MHz trac Part Number 4M x 18 600 53 ns HYB25R72180C-653 4M x 18 600 45 ns HYB25R72180C-745 4M x 18 711 50 ns HYB25R72180C-750 4M x 18 711 45 ns HYB25R72180C-645 4M x 18 800 45 ns HYB25R72180C-845 4M x 18 800 40 ns HYB25R72180C-840 Preliminary Information Page 1 Direct RAMBUS 72 Mbit (256kx18x16d) Pinouts and Definitions mounted on the circuit board). The mechanical dimensions of this package are shown in a later sectio. Refer to Section "Center-Bonded uBGA Package" on page 60. Note - pin #1 is at the A1 position. Also, note that rows 1 and 12 can be deleted for components in which these rows do not fall within die boundaries. Center-Bonded Devices - Preliminary This table shows the pin assignments of the centerbonded RDRAM package from the top-side of the package (the view looking down on the package as it is Table 1: Center-Bonded Device (top view) 8 DQA7 DQA4 CFM CFMN RQ5 RQ3 DQB0 DQB4 DQB7 7 GND VDD GND GNDa VDD GND VDD VDD GND 6 CMD DQA5 DQA2 VDDa RQ6 RQ2 DQB1 DQB5 SIO1 3 SCK DQA6 DQA1 VREF RQ7 RQ1 DQB2 DQB6 SIO0 2 VCMOS GND VDD GND GND VDD GND GND VCMOS 1 DQA8 DQA3 DQA0 CTMN CTM RQ4 RQ0 DQB3 DQB8 A B C D E F G H J 5 4 Page 2 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Table 2: Pin Description Signal I/O Type # Pins edge # Pins center SIO1,SIO0 I/O CMOSa 2 2 Serial input/output. Pins for reading from and writing to the control registers using a serial access protocol. Also used for power management. CMD I CMOSa 1 1 Command input. Pins used in conjunction with SIO0 and SIO1 for reading from and writing to the control registers. Also used for power management. SCK I CMOSa 1 1 Serial clock input. Clock source used for reading from and writing to the control registers VDD 14 6 Supply voltage for the RDRAM core and interface logic. VDDa 2 1 Supply voltage for the RDRAM analog circuitry. VCMOS 2 2 Supply voltage for CMOS input/output pins. GND 19 9 Ground reference for RDRAM core and interface. GNDa 2 1 Ground reference for RDRAM analog circuitry. Description DQA8..DQA0 I/O RSLb 9 9 Data byte A. Nine pins which carry a byte of read or write data between the Channel and the RDRAM. DQA8 is not used by RDRAMs with a x16 organization. CFM I RSLb 1 1 Clock from master. Interface clock used for receiving RSL signals from the Channel. Positive polarity. CFMN I RSLb 1 1 Clock from master. Interface clock used for receiving RSL signals from the Channel. Negative polarity 1 1 Logic threshold reference voltage for RSL signals VREF CTMN I RSLb 1 1 Clock to master. Interface clock used for transmitting RSL signals to the Channel. Negative polarity. CTM I RSLb 1 1 Clock to master. Interface clock used for transmitting RSL signals to the Channel. Positive polarity. RQ7..RQ5 or ROW2..ROW0 I RSLb 3 3 Row access control. Three pins containing control and address information for row accesses. RQ4..RQ0 or COL4..COL0 I RSLb 5 5 Column access control. Five pins containing control and address information for column accesses. DQB8.. DQB0 I/O RSLb 9 9 Data byte B. Nine pins which carry a byte of read or write data between the Channel and the RDRAM. DQB8 is not used by RDRAMs with a x16 organization. 74 54 Total pin count per package a. All CMOS signals are high-true; a high voltage is a logic one and a low voltage is logic zero. b. All RSL signals are low-true; a low voltage is a logic one and a high voltage is logic zero. INFINEON Technologies Version 1.0 Preliminary Information Page 3 Direct RAMBUS 72 Mbit (256kx18x16d) RQ7..RQ5 or ROW2..ROW0 3 DQB8..DQB0 9 CTM CTMN SCK,CMD 2 SIO0,SIO1 RQ4..RQ0 or COL4..COL0 5 CFM CFMN 2 DQA8..DQA0 9 RCLK RCLK 1:8 Demux 1:8 Demux TCLK RCLK Control Registers Packet Decode ROWR ROWA 11 5 4 9 ROP DR AV BR Match 6 R REFR Power Modes DEVID Mux DM Packet Decode COLC 5 5 4 6 COLX 5 4 XOP M DX BX COP DC S Match Row Decode BC Match C COLM 8 MB MA Write Buffer XOP Decode PRER ACT 8 PREX Mux Mux Column Decode & Mask 0 0/1 1/2 2/3 3/4 4/5 5/6 8/9 Bank 11 Bank 13 Bank 14 Bank 15 9 9 8:1 Mux Bank 12 10/11 11/12 12/13 13/14 14/15 Bank 10 9 9 TCLK 9/10 14/15 13/14 12/13 11/12 10/11 9/10 Bank 9 15 15 RCLK 1:8 Demux Write Buffer 6/7 7/8 Bank 8 8/9 SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp 7/8 TCLK 6/7 Bank 7 72 1:8 Demux Bank 6 Internal DQA Data Path Write Buffer Bank 5 5/6 8:1 Mux Bank 4 72 RCLK Bank 3 4/5 9 Bank 2 3/4 9 Bank 1 2/3 9 9 Bank 0 1/2 9 32x72 0/1 72 512x64x144 0 72 32x72 SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp SAmp Internal DQB Data Path RD, WR PREC DRAM Core Sense Amp 32x72 9 Figure 2: 64/74Mbit Direct RDRAM Block Diagram Page 4 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) ROW Pins: The principle use of these three pins is to General Description Figure 2 is a block diagram of the 64/72Mbit Direct RDRAM. It consists of two major blocks: a “core” block built from banks and sense amps similar to those found in other types of DRAM, and a Direct Rambus interface block which permits an external controller to access this core at up to 1.6GB/s. Control Registers: The CMD, SCK, SIO0, and SIO1 pins appear in the upper center of Figure 2. They are used to write and read a block of control registers. These registers supply the RDRAM configuration information to a controller and they select the operating modes of the device. The nine bit REFR value is used for tracking the last refreshed row. Most importantly, the five bit DEVID specifies the device address of the RDRAM on the Channel. Clocking: The CTM and CTMN pins (Clock-ToMaster) generate TCLK (Transmit Clock), the internal clock used to transmit read data. The CFM and CFMN pins (Clock-From-Master) generate RCLK (Receive Clock), the internal clock signal used to receive write data and to receive the ROW and COL pins. DQA,DQB Pins: These 18 pins carry read (Q) and write (D) data across the Channel. They are multiplexed/de-multiplexed from/to two 72-bit data paths (running at one-eighth the data frequency) inside the RDRAM. Banks: The 8Mbyte core of the RDRAM is divided into sixteen 0.5Mbyte banks, each organized as 512 rows, with each row containing 64 dualocts, and each dualoct containing 16 bytes. A dualoct is the smallest unit of data that can be addressed. Sense Amps: The RDRAM contains 17 sense amps. Each sense amp consists of 512 bytes of fast storage (256 for DQA and 256 for DQB) and can hold one-half of one row of one bank of the RDRAM. The sense amp may hold any of the 512 half-rows of an associated bank. However, each sense amp is shared between two adjacent banks of the RDRAM (except for numbers 0 and 15). This introduces the restriction that adjacent banks may not be simultaneously accessed. RQ Pins: These pins carry control and address information. They are broken into two groups. RQ7..RQ5 are also called ROW2..ROW0, and are used primarily for controlling row accesses. RQ4..RQ0 are also called COL4..COL0, and are used primarily for controlling column accesses. INFINEON Technologies Version 1.0 manage the transfer of data between the banks and the sense amps of the RDRAM. These pins are de-multiplexed into a 24-bit ROWA (row-activate) or ROWR (row-operation) packet. COL Pins: The principle use of these five pins is to manage the transfer of data between the DQA/DQB pins and the sense amps of the RDRAM. These pins are de-multiplexed into a 23-bit COLC (column-operation) packet and either a 17-bit COLM (mask) packet or a 17bit COLX (extended-operation) packet. ACT Command: An ACT (activate) command from an ROWA packet causes one of the 512 rows of the selected bank to be loaded to its associated sense amps (two 256 byte sense amps for DQA and two for DQB). PRER Command: A PRER (precharge) command from an ROWR packet causes the selected bank to release its two associated sense amps, permitting a different row in that bank to be activated, or permitting adjacent banks to be activated. RD Command: The RD (read) command causes one of the 64 dualocts of one of the sense amps to be transmitted on the DQA/DQB pins of the Channel. WR Command: The WR (write) command causes a dualoct received from the DQA/DQB data pins of the Channel to be loaded into the write buffer. There is also space in the write buffer for the BC bank address and C column address information. The data in the write buffer is automatically retired (written with optional bytemask) to one of the 64 dualocts of one of the sense amps during a subsequent COP command. A retire can take place during a RD, WR, or NOCOP to another device, or during a WR or NOCOP to the same device. The write buffer will not retire during a RD to the same device. The write buffer reduces the delay needed for the internal DQA/DQB data path turn-around. PREC Precharge: The PREC, RDA and WRA commands are similar to NOCOP, RD and WR, except that a precharge operation is performed at the end of the column operation. These commands provide a second mechanism for performing precharge. PREX Precharge: After a RD command, or after a WR command with no byte masking (M=0), a COLX packet may be used to specify an extended operation (XOP). The most important XOP command is PREX. This command provides a third mechanism for performing precharge. Preliminary Information Page 5 Direct RAMBUS 72 Mbit (256kx18x16d) Packet Format Figure 3 shows the formats of the ROWA and ROWR packets on the ROW pins. Table 3 describes the fields which comprise these packets. DR4T and DR4F bits are encoded to contain both the DR4 device address bit and a framing bit which allows the ROWA or ROWR packet to be recognized by the RDRAM. The AV (ROWA/ROWR packet selection) bit distinguishes between the two packet types. Both the ROWA and ROWR packet provide a five bit device address and a four bit bank address. An ROWA packet uses the remaining bits to specify a nine bit row address, and the ROWR packet uses the remaining bits for an eleven bit opcode field. Note the use of the “RsvX” notation to reserve bits for future address field extension. Table 3: Field Description for ROWA Packet and ROWR Packet Field Description DR4T,DR4F Bits for framing (recognizing) a ROWA or ROWR packet. Also encodes highest device address bit. DR3..DR0 Device address for ROWA or ROWR packet. BR3..BR0 Bank address for ROWA or ROWR packet. RsvB denotes bits ignored by the RDRAM. AV Selects between ROWA packet (AV=1) and ROWR packet (AV=0). R8..R0 Row address for ROWA packet. RsvR denotes bits ignored by the RDRAM. ROP10..ROP0 Opcode field for ROWR packet. Specifies precharge, refresh, and power management functions. Figure 3 also shows the formats of the COLC, COLM, and COLX packets on the COL pins. Table 4 describes the fields which comprise these packets. The COLC packet uses the S (Start) bit for framing. A COLM or COLX packet is aligned with this COLC packet, and is also framed by the S bit. The 23 bit COLC packet has a five bit device address, a four bit bank address, a six bit column address, and a four bit opcode. The COLC packet specifies a read or write command, as well as some power management commands. The remaining 17 bits are interpreted as a COLM (M=1) or COLX (M=0) packet. A COLM packet is used for a COLC write command which needs bytemask control. The COLM packet is associated with the COLC packet from a time tRTR earlier. An COLX packet may be used to specify an independent precharge command. It contains a five bit device address, a four bit bank address, and a five bit opcode. The COLX packet may also be used to specify some housekeeping and power management commands. The COLX packet is framed within a COLC packet but is not otherwise associated with any other packet. Table 4: Field Description for COLC Packet, COLM Packet, and COLX Packet Field Description S Bit for framing (recognizing) a COLC packet, and indirectly for framing COLM and COLX packets. DC4..DC0 Device address for COLC packet. BC3..BC0 Bank address for COLC packet. RsvB denotes bits reserved for future extension (controller drives 0’s). C5..C0 Column address for COLC packet. RsvC denotes bits ignored by the RDRAM. COP3..COP0 Opcode field for COLC packet. Specifies read, write, precharge, and power management functions. M Selects between COLM packet (M=1) and COLX packet (M=0). MA7..MA0 Bytemask write control bits. 1=write, 0=no-write. MA0 controls the earliest byte on DQA8..0. MB7..MB0 Bytemask write control bits. 1=write, 0=no-write. MB0 controls the earliest byte on DQB8..0. DX4..DX0 Device address for COLX packet. BX3..BX0 Bank address for COLX packet. RsvB denotes bits reserved for future extension (controller drives 0’s). XOP4..XOP0 Opcode field for COLX packet. Specifies precharge, IOL control, and power management functions. Page 6 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) T0 T1 T2 T3 T8 CTM/CFM T9 T 10 T11 CTM/CFM ROW2 DR4T DR2 BR0 BR3 RsvR R8 R5 R2 ROW2 DR4T DR2 BR0 BR3 ROW1 DR4F DR1 BR1 RsvB RsvR R7 R4 R1 ROW1 DR4F DR1 BR1 RsvB ROP9 ROP7 ROP4 ROP1 ROW0 R3 R0 ROW0 DR3 DR0 BR2 RsvB AV=1 R6 DR3 DR0 BR2 RsvB AV=0 ROP6 ROP3 ROP0 ROWA Packet T0 T1 T2 ROP10 ROP8 ROP5 ROP2 ROWR Packet T3 T 0 T 1 T 2 T 3 T 4 T 5 T6 T 7 T 8 T 9 T10 T 11 T 12 T 13 T14 T 15 CTM/CFM CTM/CFM COL4 DC4 S=1 RsvC C4 COL3 DC3 C5 C3 COL2 DC2 COP1 RsvB BC2 C2 COL1 DC1 COP0 RsvB BC1 C1 COL0 DC0 COP2 COP3 BC3 BC0 C0 ROW2 ..ROW0 ACT a0 COL4 ..COL0 WR b1 PRER c0 tPACKET MSK (b1) PREX d0 DQA8..0 DQB8..0 COLC Packet T8 T9 T 10 T11 CTM/CFM a T 12 T13 T 14 T15 CTM/CFM COL4 S=1a MA7 MA5 MA3 MA1 COL4 S=1b DX4 XOP4 RsvB BX1 COL3 M=1 MA6 MA4 MA2 MA0 COL3 M=0 DX3 XOP3 RsvB BX0 COL2 MB7 MB4 MB1 COL2 DX2 XOP2 BX3 COL1 MB6 MB3 MB0 COL1 DX1 XOP1 BX2 COL0 MB5 MB2 COL0 DX0 XOP0 The COLM is associated with a previous COLC, and is aligned with the present COLC, indicated by the Start bit (S=1) position. b COLM Packet COLX Packet The COLX is aligned with the present COLC, indicated by the Start bit (S=1) position. Figure 3: Packet Formats INFINEON Technologies Version 1.0 Preliminary Information Page 7 Direct RAMBUS 72 Mbit (256kx18x16d) Field Encoding Summary Table 5 shows how the six device address bits are decoded for the ROWA and ROWR packets. The DR4T and DR4F encoding merges a fifth device bit with a framing bit. When neither bit is asserted, the device is not selected. Note that a broadcast operation is indicated when both bits are set. Broadcast operation would typically be used for refresh and power management commands. If the device is selected, the DM (DeviceMatch) signal is asserted and an ACT or ROP command is performed. Table 5: Device Field Encodings for ROWA Packet and ROWR Packet DR4T DR4F Device Selection Device Match signal (DM) 1 1 All devices (broadcast) DM is set to 1 0 1 One device selected DM is set to 1 if {DEVID4..DEVID0} == {0,DR3..DR0} else DM is set to 0 1 0 One device selected DM is set to 1 if {DEVID4..DEVID0} == {1,DR3..DR0} else DM is set to 0 0 0 No packet present DM is set to 0 Table 6 shows the encodings of the remaining fields of the ROWA and ROWR packets. An ROWA packet is specified by asserting the AV bit. This causes the specified row of the specified bank of this device to be loaded into the associated sense amps. An ROWR packet is specified when AV is not asserted. An 11 bit opcode field encodes a command for one of the banks of this device. The PRER command causes a bank and its two associated sense amps to precharge, so another row or an adjacent bank may be activated. The REFA (refresh-activate) command is similar to the ACT command, except the row address comes from an internal register REFR, and REFR is incremented at the largest bank address. The REFP (refresh-precharge) command is identical to a PRER command. The NAPR, NAPRC, PDNR, ATTN, and RLXR commands are used for managing the power dissipation of the RDRAM and are described in more detail in “Power State Management” on page 38. The TCEN and TCAL commands are used to adjust the output driver slew rate and they are described in more detail in “Current and Temperature Control” on page 43. Table 6: ROWA Packet and ROWR Packet Field Encodings ROP10..ROP0 Field DM a AV 0 Name Command Description 10 9 8 7 6 5 4 3 2:0 - - - - - - - - - --- 1 1 Row address 1 0 1 1 0 0 0 xc x x 1 0 0 0 0 1 1 0 0 x 1 0 1 0 1 0 1 0 0 x 000 REFP Precharge bank BR3..BR0 of this device after REFA (see Figure 50). 1 0 x x 0 0 0 0 1 x 000 PDNR Move this device into the powerdown (PDN) power state (see Figure 47). 1 0 x x 0 0 0 1 0 x 000 NAPR Move this device into the nap (NAP) power state (see Figure 47). 1 0 x x 0 0 0 1 1 x 000 NAPRC Move this device into the nap (NAP) power state conditionally Move this device into the attention (ATTN) power state (see Figure 45). - No operation. ACT Activate row R8..R0 of bank BR3..BR0 of device and move device to ATTNb. 000 PRER Precharge bank BR3..BR0 of this device. 000 REFA Refresh (activate) row REFR8..REFR0 of bank BR3..BR0 of device. Increment REFR if BR3..BR0 = 1111 (see Figure 50). 1 0 x x x x x x x 0 000 ATTNb 1 0 x x x x x x x 1 000 RLXR Move this device into the standby (STBY) power state (see Figure 46). 1 0 0 0 0 0 0 0 0 x 001 TCAL Temperature calibrate this device (see Figure 52). 1 0 0 0 0 0 0 0 0 x 010 TCEN Temperature calibrate/enable this device (see Figure 52). 1 0 0 0 0 0 0 0 0 0 000 NOROP No operation. a. The DM (Device Match signal) value is determined by the DR4T,DR4F, DR3..DR0 field of the ROWA and ROWR packets. See Table 5. b. The ATTN command does not cause a RLX-to-ATTN transition for a broadcast operation (DR4T/DR4F=1/1). c. An “x” entry indicates which commands may be combined. For instance, the three commands PRER/NAPRC/RLXR may be specified in one ROP value (011000111000). Page 8 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Table 7 shows the COP field encoding. The device must be in the ATTN power state in order to receive COLC packets. The COLC packet is used primarily to specify RD (read) and WR (write) commands. Retire operations (moving data from the write buffer to a sense amp) happen automatically. See Figure 17 for a more detailed description. The COLC packet can also specify a PREC command, which precharges a bank and its associated sense amps. The RDA/WRA commands are equivalent to combining RD/WR with a PREC. RLXC (relax) performs a power mode transition. See “Power State Management” on page 38. Table 7: COLC Packet Field Encodings S DC4.. DC0 (select device)a 0 ---- ----- - No operation. 1 /= (DEVID4 ..0) ----- - Retire write buffer of this device. 1 == (DEVID4 ..0) x000b NOCOP Retire write buffer of this device. 1 == (DEVID4 ..0) x001 WR 1 == (DEVID4 ..0) x010 RSRV Reserved, no operation. 1 == (DEVID4 ..0) x011 RD Read column C5..C0 of bank BC3..BC0 of this device. 1 == (DEVID4 ..0) x100 PREC Retire write buffer of this device, then precharge bank BC3..BC0 (see Figure 14). 1 == (DEVID4 ..0) x101 WRA Same as WR, but precharge bank BC3..BC0 after write buffer (with new data) is retired. 1 == (DEVID4 ..0) x110 RSRV Reserved, no operation. 1 == (DEVID4 ..0) x111 RDA Same as RD, but precharge bank BC3..BC0 afterward. 1 == (DEVID4 ..0) 1xxx RLXC Move this device into the standby (STBY) power state (see Figure 46). COP3..0 Name Command Description Retire write buffer of this device, then write column C5..C0 of bank BC3..BC0 to write buffer. a. “/=” means not equal, “==” means equal. b. An “x” entry indicates which commands may be combined. For instance, the two commands WR/RLXC may be specified in one COP value (1001). Table 8 shows the COLM and COLX field encodings. The M bit is asserted to specify a COLM packet with two 8 bit bytemask fields MA and MB. If the M bit is not asserted, an COLX is specified. It has device and bank address fields, and an opcode field. The primary use of the COLX packet is to permit an independent PREX (precharge) command to be specified without consuming control bandwidth on the ROW pins. It is also used for the CAL(calibrate) and SAM (sample) current control commands (see “Current and Temperature Control” on page 43), and for the RLXX power mode command (see “Power State Management” on page 38). Table 8: COLM Packet and COLX Packet Field Encodings M DX4 .. DX0 (selects device) 1 ---- - MSK MB/MA bytemasks used by WR/WRA. 0 /= (DEVID4 ..0) - - No operation. 0 == (DEVID4 ..0) 00000 NOXOP No operation. 0 == (DEVID4 ..0) 1xxx0a PREX Precharge bank BX3..BX0 of this device (see Figure 14). 0 == (DEVID4 ..0) x10x0 CAL Calibrate (drive) I OL current for this device (see Figure 51). 0 == (DEVID4 ..0) x11x0 CAL/SAM Calibrate (drive) and Sample ( update) I OL current for this device (see Figure 51). 0 == (DEVID4 ..0) xxx10 RLXX Move this device into the standby (STBY) power state (see Figure 46). 0 == (DEVID4 ..0) xxxx1 RSRV Reserved, no operation. XOP4..0 Name Command Description a. An “x” entry indicates which commands may be combined. For instance, the two commands PREX/RLXX may be specified in one XOP value (10010). INFINEON Technologies Version 1.0 Preliminary Information Page 9 Direct RAMBUS 72 Mbit (256kx18x16d) DQ Packet Timing Figure 4 shows the timing relationship of COLC packets with D and Q data packets. This document uses a specific convention for measuring time intervals between packets: all packets on the ROW and COL pins (ROWA, ROWR, COLC, COLM, COLX) use the trailing edge of the packet as a reference point, and all packets on the DQA/DQB pins (D and Q) use the leading edge of the packet as a reference point. An RD or RDA command will transmit a dualoct of read data Q a time tCAC later. This time includes one to five cycles of round-trip propagation delay on the Channel. The tCAC parameter may be programmed to a one of a range of values ( 7, 8, 9, 10, 11, or 12 tCYCLE). The value chosen depends upon the number of RDRAM devices on the Channel and the RDRAM timing bin. See Figure 39 for more information. T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 A WR or WRA command will receive a dualoct of write data D a time tCWD later. This time does not need to include the round-trip propagation time of the Channel since the COLC and D packets are traveling in the same direction. When a Q packet follows a D packet (shown in the left half of the figure), a gap (tCAC -tCWD) will automatically appear between them because the tCWD value is always less than the tCAC value. There will be no gap between the two COLC packets with the WR and RD commands which schedule the D and Q packets. When a D packet follows a Q packet (shown in the right half of the figure), no gap is needed between them because the tCWD value is less than the tCAC value. However, , a gap of tCAC -tCWD or greater must be inserted between the COLC packets with the RD WR commands by the controller so the Q and D packets do not overlap. T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM This gap on the DQA/DQB pins appears automatically ROW2 ..ROW0 tCAC-tCWD tCAC -tCWD WR a1 ••• RD b1 DQA8..0 DQB8..0 RD c1 D (a1) tCAC WR d1 WR d1 WR d1 WR d1 WR d1 WR d1 ••• tCWD COL4 ..COL0 This gap on the COL pins must be inserted by the controller Q (b1) Q (b1) Q (a1) Q (a1) Q (a1) Q (a1) ••• tCWD ••• Q (c1) D (d1) Q (c1) D (d1) Q (c1) D (d1) Q (c1) D (d1) Q (a1) D (d1) Q (a1) D (d1) ••• tCAC Figure 4: Read (Q) and Write (D) Data Packet - Timing for tCAC = 7, 8, 9, 10, 11, or 12 tCYCLE COLM Packet to D Packet Mapping Figure 5 shows a write operation initiated by a WR command in a COLC packet. If a subset of the 16 bytes of write data are to be written, then a COLM packet is transmitted on the COL pins a time tRTR after the COLC packet containing the WR command. The M bit of the COLM packet is set to indicate that it contains the MA and MB mask fields. Note that this COLM packet is aligned with the COLC packet which causes the write buffer to be retired. See Figure 17 for more details. If all 16 bytes of the D data packet are to be written, then no further control information is required. The packet slot that would have been used by the COLM packet (tRTR after the COLC packet) is available to be Page 10 used as an COLX packet. This could be used for a PREX precharge command or for a housekeeping command (this case is not shown). The M bit is not asserted in an COLX packet and causes all 16 bytes of the previous WR to be written unconditionally. Note that a RD command will never need a COLM packet, and will always be able to use the COLX packet option (a read operation has no need for the byte-write-enable control bits). Figure 5 also shows the mapping between the MA and MB fields of the COLM packet and bytes of the D packet on the DQA and DQB pins. Each mask bit controls whether a byte of data is written (=1) or not written (=0). Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T13 T 14 T 15 T16 T17 T 18 T 19 T20 T21 T 22 T 23 T24 T25 T26 T 27 T28 T29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T42 T 43 T44 T45 T 46 T 47 CTM/CFM ROW2 ..ROW0 ACT a0 PRER a2 ACT b0 tRTR COL4 ..COL0 WR a1 retire (a1) MSK (a1) tCWD DQA8..0 DQB8..0 D (a1) Transaction a: WR a0 = {Da,Ba,Ra} a1 = {Da,Ba,Ca1} a3 = {Da,Ba} COLM Packet T17 T 18 T19 CTM/CFM D Packet T 20 T 19 T20 T 21 T22 COL4 MA7 MA5 MA3 MA1 DQB8 DB8 DB17 DB26 DB35 DB45 DB53 DB62 DB71 COL3 M=1 MA6 MA4 MA2 MA0 DQB7 DB7 DB16 DB25 DB34 DB44 DB52 DB61 DB70 COL2 MB7 MB4 MB1 ••• CTM/CFM COL1 MB6 MB3 MB0 DQB1 DB1 DB10 DB19 DB28 DB37 DB46 DB55 DB64 COL0 MB5 MB2 DQB0 DB0 DB9 DB18 DB27 DB36 DB45 DB54 DB63 MB0 MB1 MB2 MB3 MB4 MB5 MB6 MB7 Each bit of the MB7..MB0 field controls writing (=1) or no writing (=0) of the indicated DB bits when the M bit of the COLM packet is one. DQA8 DA8 DA17 DA26 DA35 DA45 DA53 DA62 DA71 DQA7 DA7 DA16 DA25 DA34 DA44 DA52 DA61 DA70 ••• When M=1, the MA and MB fields control writing of individual data bytes. When M=0, all data bytes are written unconditionally. Each bit of the MA7..MA0 field controls writing (=1) or no writing (=0) of the indicated DA bits when the M bit of the COLM packet is one. DQA1 DA1 DA10 DA19 DA28 DA37 DA46 DA55 DA64 DQA0 DA0 DA9 DA18 DA27 DA36 DA45 DA54 DA63 MA0 MA1 MA2 MA3 MA4 MA5 MA6 MA7 Figure 5: Mapping Between COLM Packet and D Packet for WR Command INFINEON Technologies Version 1.0 Preliminary Information Page 11 Direct RAMBUS 72 Mbit (256kx18x16d) ROW-to-ROW Packet Interaction T0 T 1 T2 T 3 T4 T 5 T6 T 7 T8 T 9 T10 T 11 T12 T 13 T 14 T 15 T16 T17 T18 T 19 T CTM/CFM tRRDELAY ROW2 ..ROW0 ROPa a0 ROPb b0 Cases RR5 through RR8 show an ACT command followed by a PRER command. In cases RR5 and RR6, there are no restrictions since the commands are to different devices or to non-adjacent banks of the same device. In cases RR7 and RR8, the tRAS restriction means the activated bank must wait before it can be precharged. COL4 ..COL0 DQA8..0 DQB8..0 Transaction a: ROPa Transaction b: ROPb Cases RR1 through RR4 show two successive ACT commands. In case RR1, there is no restriction since the ACT commands are to different devices. In case RR2, the tRR restriction applies to the same device with nonadjacent banks. Cases RR3 and RR4 are illegal (as shown) since bank Ba needs to be precharged. If a PRER to Ba, Ba+1, or Ba-1 is inserted, tRRDELAY is tRC (tRAS to the PRER command, and tRP to the next ACT). a0 = {Da,Ba,Ra} b0= {Db,Bb,Rb} Figure 6: ROW-to-ROW Packet Interaction- Timing Figure 6 shows two packets on the ROW pins separated by an interval tRRDELAY which depends upon the packet contents. No other ROW packets are sent to banks {Ba,Ba+1,Ba-1} between packet “a” and packet “b” unless noted otherwise. Table 9 summarizes the tRRDELAY values for all possible cases. Cases RR9 through RR12 show a PRER command followed by an ACT command. In cases RR9 and RR10, there are essentially no restrictions since the commands are to different devices or to non-adjacent banks of the same device. RR10a and RR10b depend upon whether a bracketed bank (Ba+-1) is precharged or activated. In cases RR11 and RR12, the same and adjacent banks must all wait tRP for the sense amp and bank to precharge before being activated. Table 9: ROW-to-ROW Packet Interaction - Rules Case # ROPa Da Ba Ra ROPb Db Bb Rb tRRDELAY Example RR1 ACT Da Ba Ra ACT /= Da xxxx x..x tPACKET Figure 11 RR2 ACT Da Ba Ra ACT == Da /= {Ba,Ba+1,Ba-1} x..x tRR Figure 11 RR3 ACT Da Ba Ra ACT == Da == {Ba+1,Ba-1} x..x tRC - illegal unless PRER to Ba/Ba+1/Ba-1 Figure 10 RR4 ACT Da Ba Ra ACT == Da == {Ba} x..x tRC - illegal unless PRER to Ba/Ba+1/Ba-1 Figure 10 RR5 ACT Da Ba Ra PRER /= Da xxxx x..x tPACKET Figure 11 RR6 ACT Da Ba Ra PRER == Da /= {Ba,Ba+1,Ba-1} x..x tPACKET Figure 11 RR7 ACT Da Ba Ra PRER == Da == { Ba+1,Ba-1} x..x tRAS Figure 10 RR8 ACT Da Ba Ra PRER == Da == {Ba} x..x tRAS Figure 15 RR9 PRER Da Ba Ra ACT /= Da xxxx x..x tPACKET Figure 12 RR10 PRER Da Ba Ra ACT == Da /= {Ba,Ba+-1,Ba+-2} x..x tPACKET Figure 12 RR10a PRER Da Ba Ra ACT == Da == {Ba+2} x..x tPACKET/tRP if Ba+1 is precharged/activated. RR10b PRER Da Ba Ra ACT == Da == {Ba-2} x..x tPACKET/tRP if Ba-1 is precharged/activated. RR11 PRER Da Ba Ra ACT == Da == {Ba+1,Ba-1} x..x tRP Figure 10 RR12 PRER Da Ba Ra ACT == Da == {Ba} x..x tRP Figure 10 RR13 PRER Da Ba Ra PRER /= Da xxxx x..x tPACKET Figure 12 RR14 PRER Da Ba Ra PRER == Da /= {Ba,Ba+1,Ba-1} x..x tPP Figure 12 RR15 PRER Da Ba Ra PRER == Da == {Ba+1,Ba-1} x..x tPP Figure 12 RR16 PRER Da Ba Ra PRER == Da == Ba x..x tPP Figure 12 Page 12 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) ROW-to-ROW Interaction - continued Cases RR13 through RR16 summarize the combinations of two successive PRER commands. In case RR13 there is no restriction since two devices are addressed. In RR14, tPP applies, since the same device is addressed. In RR15 and RR16, the same bank or an adjacent bank may be given repeated PRER commands with only the tPP restriction. Two adjacent banks can’t be activate simultaneously. A precharge command to one bank will thus affect the state of the adjacent banks (and sense amps). If bank Ba is activate and a PRER is directed to Ba, then bank Ba will be precharged along with sense amps Ba-1/Ba and Ba/Ba+1. If bank Ba+1 is activate and a PRER is directed to Ba, then bank Ba+1 will be precharged along with sense amps Ba/Ba+1 and Ba+1/Ba+2. If bank Ba-1 is activate and a PRER is directed to Ba, then bank Ba-1 will be precharged along with sense amps Ba/Ba-1 and Ba-1/Ba-2. A ROW packet may contain commands other than ACT or PRER. The REFA and REFP commands are equivalent to ACT and PRER for interaction analysis purposes. The interaction rules of the NAPR, NAPRC, PDNR, RLXR, ATTN, TCAL, and TCEN commands are discussed in later sections (see Table 6 for cross-ref). ROW-to-COL Packet Interaction Figure 7 shows two packets on the ROW and COL pins. They must be separated by an interval tRCDELAY which depends upon the packet contents. Table 10 summarizes the tRCDELAY values for all possible cases. Note that if the COL packet is earlier than the ROW packet, it is considered a COL-to-ROW packet interaction. Cases RC1 through RC5 summarize the rules when the ROW packet has an ACT command. Figure 15 and Figure 16 show examples of RC5 - an activation followed by a read or write. RC4 is an illegal situation, since a read or write of a precharged banks is being attempted (remember that for a bank to be activated, adjacent banks must be precharged). In cases RC1, RC2, and RC3, there is no interaction of the ROW and COL packets. T0 T 1 T2 T 3 T4 T5 T6 T7 T8 T9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T18 T 19 T CTM/CFM tRCDELAY ROW2 ..ROW0 ROPa a0 COL4 ..COL0 COPb b1 DQA8..0 DQB8..0 Transaction a: ROPa Transaction b: COPb a0 = {Da,Ba,Ra} b1= {Db,Bb,Cb1} Figure 7: ROW-to-COL Packet Interaction- Timing Cases RC6 through RC8 summarize the rules when the ROW packet has a PRER command. There is either no interaction (RC6 through RC9) or an illegal situation with a read or write of a precharged bank (RC9). The COL pins can also schedule a precharge operation with a RDA, WRA, or PREC command in a COLC packet or a PREX command in a COLX packet. The constraints of these precharge operations may be converted to equivalent PRER command constraints using the rules summarized in Figure 14. Table 10: ROW-to-COL Packet Interaction - Rules Case # ROPa Da Ba Ra COPb Db Bb Cb1 tRCDELAY RC1 ACT Da Ba Ra NOCOP,RD,retire /= Da xxxx x..x 0 RC2 ACT Da Ba Ra NOCOP == Da xxxx x..x 0 RC3 ACT Da Ba Ra RD,retire == Da /= {Ba,Ba+1,Ba-1} x..x 0 RC4 ACT Da Ba Ra RD,retire == Da == {Ba+1,Ba-1} x..x Illegal RC5 ACT Da Ba Ra RD,retire == Da == Ba x..x tRCD RC6 PRER Da Ba Ra NOCOP,RD,retire /= Da xxxx x..x 0 RC7 PRER Da Ba Ra NOCOP == Da xxxx x..x 0 RC8 PRER Da Ba Ra RD,retire == Da /= {Ba,Ba+1,Ba-1} x..x 0 RC9 PRER Da Ba Ra RD,retire == Da == {Ba+1,Ba-1} x..x Illegal INFINEON Technologies Version 1.0 Preliminary Information Example Figure 15 Page 13 Direct RAMBUS 72 Mbit (256kx18x16d) COL-to-COL Packet Interaction T0 T 1 T2 T 3 T4 T 5 T6 T 7 T8 T 9 T10 T 11 T12 T 13 T 14 T 15 gap is needed. For cases CC1, CC2, CC4, and CC5, there is no restriction (tCCDELAY is tCC). T16 T17 T18 T 19 T CTM/CFM ROW2 ..ROW0 COL4 ..COL0 tCCDELAY COPa a1 COPb b1 COPc c1 DQA8..0 DQB8..0 Transaction a: COPa Transaction b: COPb Transaction c: COPc a1 = {Da,Ba,Ca1} b1 = {Db,Bb,Cb1} c1 = {Dc,Bc,Cc1} Figure 8: COL-to-COL Packet Interaction- Timing Figure 8 shows three arbitrary packets on the COL pins. Packets “b” and “c” must be separated by an interval tCCDELAY which depends upon the command and address values in all three packets. Table 11 summarizes the tCCDELAY values for all possible cases. Cases CC1 through CC5 summarize the rules for every situation other than the case when COPb is a WR command and COPc is a RD command. In CC3, when a RD command is followed by a WR command, a gap of tCAC -tCWD must be inserted between the two COL packets. See Figure 4 for more explanation of why this In cases CC6 through CC10, COPb is a WR command and COPc is a RD command. The tCCDELAY value needed between these two packets depends upon the command and address in the packet with COPa. In particular, in case CC6 when there is WR-WR-RD command sequence directed to the same device, a gap will be needed between the packets with COPb and COPc. The gap will need a COLC packet with a NOCOP command directed to any device in order to force an automatic retire to take place. Figure 18 (right) provides a more detailed explanation of this case. In case CC10, there is a RD-WR-RD sequence directed to the same device. If a prior write to the same device is unretired when COPa is issued, then a gap will be needed between the packets with COPb and COPc as in case CC6. The gap will need a COLC packet with a NOCOP command directed to any device in order to force an automatic retire to take place. Cases CC7, CC8, and CC9 have no restriction (tCCDELAY is tCC). For the purposes of analyzing COL-to-ROW interactions, the PREC, WRA, and RDA commands of the COLC packet are equivalent to the NOCOP, WR, and RD commands. These commands also cause a precharge operation PREC to take place. This precharge may be converted to an equivalent PRER command on the ROW pins using the rules summarized in Figure 14. Table 11: COL-to-COL Packet Interaction - Rules Case # COPa Da Ba Ca1 COPb Db Bb Cb1 COPc Dc Bc Cc1 tCCDELAY CC1 xxxx xxxxx x..x x..x NOCOP Db Bb Cb1 xxxx xxxxx x..x x..x tCC CC2 xxxx xxxxx x..x x..x RD,WR Db Bb Cb1 NOCOP xxxxx x..x x..x tCC CC3 xxxx xxxxx x..x x..x RD Db Bb Cb1 WR xxxxx x..x x..x tCC+tCAC -tCWD Figure 4 CC4 xxxx xxxxx x..x x..x RD Db Bb Cb1 RD xxxxx x..x x..x tCC Figure 15 CC5 xxxx xxxxx x..x x..x WR Db Bb Cb1 WR xxxxx x..x x..x tCC Figure 16 CC6 WR == Db x x..x WR Db Bb Cb1 RD == Db x..x x..x tRTR Figure 18 CC7 WR == Db x x..x WR Db Bb Cb1 RD /= Db x..x x..x tCC CC8 WR /= Db x x..x WR Db Bb Cb1 RD == Db x..x x..x tCC CC9 NOCOP == Db x x..x WR Db Bb Cb1 RD == Db x..x x..x tCC CC10 RD x x..x WR Db Bb Cb1 RD == Db x..x x..x tCC == Db COL-to-ROW Packet Interaction Example pins. They must be separated by an interval tCRDELAY which depends upon the command and address values Figure 9 shows arbitrary packets on the COL and ROW Page 14 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T13 T 14 T 15 T16 T17 T 18 T 19 T CTM/CFM tCRDELAY ROW2 ..ROW0 COL4 ..COL0 ROPb b0 CR5 is illegal because an adjacent bank can’t be activated or precharged until bank Ba is precharged first. In case CR6, the COLC packet contains a RD command, and the ROW packet contains a PRER command for the same bank. The tRDP parameter specifies the required spacing. Likewise, in case CR7, the COLC packet causes an automatic retire to take place, and the ROW packet contains a PRER command for the same bank. The tRTP parameter specifies the required spacing. COPa a1 DQA8..0 DQB8..0 Transaction a: COPa Transaction b: ROPb a1= {Da,Ba,Ca1} b0= {Db,Bb,Rb} Figure 9: COL-to-ROW Packet Interaction- Timing in the packets. Table 12 summarizes the tCRDELAY value for all possible cases. Cases CR1, CR2, CR3, and CR9 show no interaction between the COL and ROW packets, either because one of the commands is a NOP or because the packets are directed to different devices or to non-adjacent banks. Case CR4 is illegal because an already-activated bank is to be re-activated without being precharged Case Case CR8 is labeled “Hazardous” because a WR command should always be followed by an automatic retire before a precharge is scheduled. Figure 19 shows an example of what can happen when the retire is not able to happen before the precharge. For the purposes of analyzing COL-to-ROW interactions, the PREC, WRA, and RDA commands of the COLC packet are equivalent to the NOCOP, WR, and RD commands. These commands also cause a precharge operation to take place. This precharge may converted to an equivalent PRER command on the ROW pins using the rules summarized in Figure 14. A ROW packet may contain commands other than ACT or PRER. The REFA and REFP commands are equivalent to ACT and PRER for interaction analysis purposes. The interaction rules of the NAPR, PDNR, and RLXR commands are discussed in a later section. Table 12: COL-to-ROW Packet Interaction - Rules Case # COPa Da Ba Ca1 ROPb Db Bb Rb tCRDELAY CR1 NOCOP Da Ba Ca1 x..x xxxxx xxxx x..x 0 CR2 RD/WR Da Ba Ca1 x..x /= Da xxxx x..x 0 CR3 RD/WR Da Ba Ca1 x..x == Da /= {Ba,Ba+1,Ba-1} x..x 0 CR4 RD/WR Da Ba Ca1 ACT == Da == {Ba} x..x Illegal CR5 RD/WR Da Ba Ca1 ACT == Da == {Ba+1,Ba-1} x..x Illegal CR6 RD Da Ba Ca1 PRER == Da == {Ba,Ba+1,Ba-1} x..x tRDP CR7 retirea Da Ba Ca1 PRER == Da == {Ba,Ba+1,Ba-1} x..x tRTP Figure 16 CR8 WRb Da Ba Ca1 PRER == Da == {Ba,Ba+1,Ba-1} x..x 0 Figure 19 CR9 xxxx Da Ba Ca1 NOROP xxxxx xxxx x..x 0 Example Figure 15 a. This is any command which permits the write buffer of device Da to retire (see Table 7). “Ba” is the bank address in the write buffer. b. This situation is hazardous because the write buffer will be left unretired while the targeted bank is precharged. See Figure 19. INFINEON Technologies Version 1.0 Preliminary Information Page 15 Direct RAMBUS 72 Mbit (256kx18x16d) ROW-to-ROW Examples commands to the same bank must also satisfy the tRC timing parameter (RR4). Figure 10 shows examples of some of the the ROW-toROW packet spacings from Table 9. A complete sequence of activate and precharge commands is directed to a bank. The RR8 and RR12 rules apply to this sequence. In addition to satisfying the tRAS and tRP timing parameters, the separation between ACT When a bank is activated, it is necessary for adjacent banks to remain precharged. As a result, the adjacent banks will also satisfy parallel timing constraints; in the example, the RR11 and RR3 rules are analogous to the RR12 and RR4 rules. Same Device Same Device Same Device Same Device Same Device T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 Adjacent Bank Adjacent Bank Same Bank Adjacent Bank Same Bank T 26 T 27 T28 T 29 T 30 T 31 T32 T33 a0 = {Da,Ba,Ra} a1 = {Da,Ba+1} b0 = {Da,Ba+1,Rb} b0 = {Da,Ba,Rb} b0 = {Da,Ba+1,Rb} b0 = {Da,Ba,Rb} RR7 RR3 RR4 RR11 RR12 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM ROW2 ..ROW0 ACT a0 PRER a1 ACT b0 COL4 ..COL0 tRAS tRP DQA8..0 DQB8..0 tRC Figure 10: Row Packet Example unless they are directed to the same or adjacent banks or unless they are a similar command type (both PRER or both ACT) directed to the same device. Figure 11 shows examples of the ACT-to-ACT (RR1, RR2) and ACT-to-PRER (RR5, RR6) command spacings from Table 9. In general, the commands in ROW packets may be spaced an interval tPACKET apart Different Device Same Device Different Device Same Device T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 Any Bank Non-adjacent Bank Any Bank Non-adjacent Bank T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 a0 = {Da,Ba,Ra} b0 = {Db,Bb,Rb} c0 = {Da,Bc,Rc} b0 = {Db,Bb,Rb} c0 = {Da,Bc,Rc} RR1 RR2 RR5 RR6 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM ROW2 ..ROW0 COL4 ..COL0 ACT a0 tPACKET ACT b0 ACT a0 ACT c0 tRR ACT a0 PRER b0 tPACKET ACT a0 PRER c0 tPACKET DQA8..0 DQB8..0 Figure 11: Row Packet Example Page 16 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Figure 12 shows examples of the PRER-to-PRER (RR13, RR14) and PRER-to-ACT (RR9, RR10) command spacings from Table 10. The RR15 and RR16 cases (PRER-to-PRER to same or adjacent banks) are not shown, but are similar to RR14. In general, the commands in ROW packets may be spaced an interval tPACKET apart unless they are directed to the same or adjacent banks or unless they are a similar command type (both PRER or both ACT) directed to the same device. Different Device Same Device Same Device Same Device Different Device Same Device T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 Any Bank Non-adjacent Bank Adjacent Bank Same Bank Any Bank Non-adjacent Bank T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 a0 = {Da,Ba,Ra} b0 = {Db,Bb,Rb} c0 = {Da,Bc,Rc} c0 = {Da,Ba,Rc} c0 = {Da,Ba+1Rc} b0 = {Db,Bb,Rb} c0 = {Da,Bc,Rc} RR13 RR14 RR15 RR16 RR9 RR10 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM ROW2 ..ROW0 PRER a0 PRER b0 PRER a0 PRER c0 tPACKET PRER a0 tPACKET tPP ACT b0 PRER a0 ACT c0 tPACKET COL4 ..COL0 DQA8..0 DQB8..0 Figure 12: Row Packet Examples Row and Column Cycle Description Activate: A row cycle begins with the activate (ACT) operation. The activation process is destructive; the act of sensing the value of a bit in a bank’s storage cell transfers the bit to the sense amp, but leaves the original bit in the storage cell with an incorrect value. Restore: Because the activation process is destructive, a hidden operation called restore is automatically performed. The restore operation rewrites the bits in the sense amp back into the storage cells of the activated row of the bank. Read/Write: While the restore operation takes place, the sense amp may be read (RD) and written (WR) using column operations. If new data is written into the sense amp, it is automatically forwarded to the storage cells of the bank so the data in the activated row and the data in the sense amp remain identical. Precharge: When both the restore operation and the column operations are completed, the sense amp and bank are precharged (PRE). This leaves them in the proper state to begin another activate operation. Intervals: The activate operation requires the interval tRCD,MIN to complete. The hidden restore operation INFINEON Technologies Version 1.0 requires the interval tRAS,MIN - tRCD,MIN to complete. Column read and write operations are also performed during the tRAS,MIN - tRCD,MIN interval (if more than about four column operations are performed, this interval must be increased). The precharge operation requires the interval tRP,MIN to complete. Adjacent Banks: An RDRAM with a “d” designation (256Kx16dx16/18) indicates it contains “doubled banks”. This means the sense amps are shared between two adjacent banks. The only exception is that sense amp 0 and sense amp 15 are not shared. When a row in a bank is activated, the two adjacent sense amps are connected to (associated with) that bank and are not available for use by the two adjacent banks. These two adjacent banks must remain precharged while the selected bank goes through its activate, restore, read/write, and precharge operations. For example (referring to the block diagram of Figure 2), if bank 5 is accessed, sense amp 4/5 and sense amp 5/6 will both be loaded with one of the 512 rows (with 512 bytes loaded into each sense amp from the 1Kbyte row - 256 bytes to the DQA side and 256 bytes to the DQB side). While this row from bank 5 is being accessed, no rows may be accessed in banks 4 or 6 because of the sense amp sharing. Preliminary Information Page 17 Direct RAMBUS 72 Mbit (256kx18x16d) Precharge Mechanisms Figure 13 shows an example of precharge with the ROWR packet mechanism. The PRER command must occur a time tRAS after the ACT command, and a time tRP before the next ACT command. This timing will serve as a baseline aginst which the other precharge mechanisms can be compared. a0 = {Da,Ba,Ra} a5 = {Da,Ba} b0 = {Da,Ba,Rb} T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM ROW2 ..ROW0 ACT a0 PRER a5 ACT b0 COL4 ..COL0 tRAS tRP DQA8..0 DQB8..0 tRC Figure 13: Precharge via PRER Command in ROWR Packet Figure 14 (top) shows an example of precharge with a RDA command. A bank is activated with an ROWA packet on the ROW pins. Then, a series of four dualocts are read with RD commands in COLC packets on the COL pins. The fourth of these commands is a RDA, which causes the bank to automatically precharge when the final read has finished. The timing of this automatic precharge is equivalent to a PRER command in an ROWR packet on the ROW pins that is offset a time tOFFP from the COLC packet with the RDA command. The RDA command should be treated as a RD command in a COLC packet as well as a simultaneous (but offset) PRER command in an ROWR packet when analyzing interactions with other packets. Figure 14 (middle) shows an example of precharge with a WRA command. As in the RDA example, a bank is activated with an ROWA packet on the ROW pins. Then, two dualocts are written with WR commands in COLC packets on the COL pins. The second of these commands is a WRA, which causes the bank to automatically precharge when the final write has been retired. The timing of this automatic precharge is equivalent to a PRER command in an ROWR packet on the ROW pins that is offset a time tOFFP from the COLC packet that causes the automatic retire. The WRA command should be treated as a WR command in a COLC packet as well as a simultaneous (but offset) PRER command in an ROWR packet when Page 18 analyzing interactions with other packets. Note that the automatic retire is triggered by a COLC packet a time tRTR after the COLC packet with the WR command unless the second COLC contains a RD command to the same device. This is described in more detail in Figure 17. Figure 14 (bottom) shows an example of precharge with a PREX command in an COLX packet. A bank is activated with an ROWA packet on the ROW pins. Then, a series of four dualocts are read with RD commands in COLC packets on the COL pins. The fourth of these COLC packets includes an COLX packet with a PREX command. This causes the bank to precharge with timing equivalent to a PRER command in an ROWR packet on the ROW pins that is offset a time tOFFP from the COLX packet with the PREX command. Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) COLC Packet: RDA Precharge Offset T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM The RDA precharge is equivalent to a PRER command here ROW2 ..ROW0 ACT a0 ACT b0 PRER a5 tOFFP COL4 ..COL0 RD a1 RD a2 RD a3 DQA8..0 DQB8..0 RDA a4 Q (a1) Transaction a: RD a0 = {Da,Ba,Ra} Q (a2) a1 = {Da,Ba,Ca1} a3 = {Da,Ba,Ca3} Q (a3) Q (a4) a2 = {Da,Ba,Ca2} a4 = {Da,Ba,Ca4} a5 = {Da,Ba} COLC Packet: WDA Precharge Offset T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM The WRA precharge (triggered by the automatic retire) is equivalent to a PRER command here ROW2 ..ROW0 ACT a0 PRER a5 tRTR COL4 ..COL0 WR a1 WRA a2 tOFFP retire (a1) retire (a2) MSK (a1) MSK (a2) DQA8..0 DQB8..0 D (a1) Transaction a: WR ACT b0 a0 = {Da,Ba,Ra} D (a2) a1 = {Da,Ba,Ca1} a2 = {Da,Ba,Ca2} a5 = {Da,Ba} COLX Packet: PREX Precharge Offset T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM The PREX precharge command is equivalent to a PRER command here ROW2 ..ROW0 ACT a0 PRER a5 ACT b0 tOFFP COL4 ..COL0 RD a1 RD a2 RD a3 DQA8..0 DQB8..0 RD a4 PREX a5 Q (a1) Transaction a: RD a0 = {Da,Ba,Ra} Q (a2) a1 = {Da,Ba,Ca1} a3 = {Da,Ba,Ca3} Q (a3) Q (a4) a2 = {Da,Ba,Ca2} a4 = {Da,Ba,Ca4} a5 = {Da,Ba} Figure 14: Offsets for Alternate Precharge Mechanisms INFINEON Technologies Version 1.0 Preliminary Information Page 19 Direct RAMBUS 72 Mbit (256kx18x16d) Read Transaction - Example device and bank address as the a0, a1, and a2 addresses. The PRER command must occur a time tRAS or more after the original ACT command (the activation operation in any DRAM is destructive, and the contents of the selected row must be restored from the two associated sense amps of the bank during the tRAS interval). The PRER command must also occur a time tRDP or more after the last RD command. Note that the tRDP value shown is greater than the tRDP,MIN specification in Table 22. This transaction example reads two dualocts, but there is actually enough time to read three dualocts before tRDP becomes the limiting parameter rather than tRAS. If four dualocts were read, the packet with PRER would need to shift right (be delayed) by one tCYCLE (note - this case is not shown). Figure 15 shows an example of a read transaction. It begins by activating a bank with an ACT a0 command in an ROWA packet. A time tRCD later a RD a1 command is issued in a COLC packet. Note that the ACT command includes the device, bank, and row address (abbreviated as a0) while the RD command includes device, bank, and column address (abbreviated as a1). A time tCAC after the RD command the read data dualoct Q(a1) is returned by the device. Note that the packets on the ROW and COL pins use the end of the packet as a timing reference point, while the packets on the DQA/DQB pins use the beginning of the packet as a timing reference point. A time tCC after the first COLC packet on the COL pins a second is issued. It contains a RD a2 command. The a2 address has the same device and bank address as the a1 address (and a0 address), but a different column address. A time tCAC after the second RD command a second read data dualoct Q(a2) is returned by the device. Finally, an ACT b0 command is issued in an ROWR packet on the ROW pins. The second ACT command must occur a time tRC or more after the first ACT command and a time tRP or more after the PRER command. This ensures that the bank and its associated sense amps are precharged. This example assumes that the second transaction has the same device and bank address as the first transaction, but a different row address. Transaction b may not be started until transaction a has finished. However, transactions to other banks or other devices may be issued during transaction a. Next, a PRER a3 command is issued in an ROWR packet on the ROW pins. This causes the bank to precharge so that a different row may be activated in a subsequent transaction or so that an adjacent bank may be activated. The a3 address includes the same T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM tRC ROW2 ..ROW0 ACT a0 PRER a3 tRAS COL4 ..COL0 RD a1 tRCD tRP RD a2 tCC tRDP DQA8..0 DQB8..0 Q (a1) tCAC Transaction a: RD Transaction b: xx ACT b0 a0 = {Da,Ba,Ra} b0 = {Da,Ba,Rb} Q (a2) tCAC a1 = {Da,Ba,Ca1} a2 = {Da,Ba,Ca2} a3 = {Da,Ba} Figure 15: Read Transaction Example Page 20 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Write Transaction - Example delayed, then the COLM packet (if used) must also be delayed. Figure 16 shows an example of a write transaction. It begins by activating a bank with an ACT a0 command in an ROWA packet. A time tRCD-tRTR later a WR a1 command is issued in a COLC packet (note that the tRCD interval is measured to the end of the COLC packet with the first retire command). Note that the ACT command includes the device, bank, and row address (abbreviated as a0) while the WR command includes device, bank, and column address (abbreviated as a1). A time tCWD after the WR command the write data dualoct D(a1) is issued. Note that the packets on the ROW and COL pins use the end of the packet as a timing reference point, while the packets on the DQA/DQB pins use the beginning of the packet as a timing reference point. Next, a PRER a3 command is issued in an ROWR packet on the ROW pins. This causes the bank to precharge so that a different row may be activated in a subsequent transaction or so that an adjacent bank may be activated. The a3 address includes the same device and bank address as the a0, a1, and a2 addresses. The PRER command must occur a time tRAS or more after the original ACT command (the activation operation in any DRAM is destructive, and the contents of the selected row must be restored from the two associated sense amps of the bank during the tRAS interval). A PRER a3 command is issued in an ROWR packet on the ROW pins. The PRER command must occur a time tRTP or more after the last COLC which causes an automatic retire. A time tCC after the first COLC packet on the COL pins a second COLC packet is issued. It contains a WR a2 command. The a2 address has the same device and bank address as the a1 address (and a0 address), but a different column address. A time tCWD after the second WR command a second write data dualoct D(a2) is issued. Finally, an ACT b0 command is issued in an ROWR packet on the ROW pins. The second ACT command must occur a time tRC or more after the first ACT command and a time tRP or more after the PRER command. This ensures that the bank and its associated sense amps are precharged. This example assumes that the second transaction has the same device and bank address as the first transaction, but a different row address. Transaction b may not be started until transaction a has finished. However, transactions to other banks or other devices may be issued during transaction a. A time tRTR after each WR command an optional COLM packet MSK (a1) is issued, and at the same time a COLC packet is issued causing the write buffer to automatically retire. See Figure 17 for more detail on the write/retire mechanism. If a COLM packet is not used, all data bytes are unconditionally written. If the COLC packet which causes the write buffer to retire is T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM tRC ROW2 ..ROW0 ACT a0 PRER a3 tRCD ACT b0 tRAS COL4 ..COL0 WR a1 WR a2 tRP retire (a1) retire (a2) MSK (a1) MSK (a2) tRTR DQA8..0 DQB8..0 tRTR D (a1) tCC tRTP D (a2) tCWD tCWD Transaction a: WR Transaction b: xx a0 = {Da,Ba,Ra} b0 = {Da,Ba,Rb} a1 = {Da,Ba,Ca1} a2 = {Da,Ba,Ca2} a3 = {Da,Ba} Figure 16: Write Transaction Example INFINEON Technologies Version 1.0 Preliminary Information Page 21 Direct RAMBUS 72 Mbit (256kx18x16d) Write/Retire - Examples The process of writing a dualoct into a sense amp of an RDRAM bank occurs in two steps. The first step consists of transporting the write command, write address, and write data into the write buffer. The second step happens when the RDRAM automatically retires the write buffer (with an optional bytemask) into the sense amp. This two-step write process reduces the natural turn-around delay due to the internal bidirectional data pins. Figure 17 (left) shows an example of this two step process. The first COLC packet contains the WR command and an address specifying device, bank and column. The write data dualoct follows a time tCWD later. This information is loaded into the write buffer of T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 CTM/CFM ROW2 ..ROW0 COL4 ..COL0 T16 T17 the specified device. The COLC packet which follows a time tRTR later will retire the write buffer. The retire will happen automatically unless (1) a COLC packet is not framed (no COLC packet is present and the S bit is zero), or (2) the COLC packet contains a RD command to the same device. If the retire does not take place at time tRTR after the original WR command, then the device continues to frame COLC packets, looking for the first that is not a RD directed to itself. A bytemask MSK(a1) may be supplied in a COLM packet aligned with the COLC that retires the write buffer at time tRTR after the WR command. The memory controller must be aware of this two-step write/retire process. Controller performance can be improved, but only if the controller design accounts for several side effects. T 18 T 19 T20 T 21 T 22 T23 0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T10 T 11 T12 T 13 T14 T 15 T16 T17 T18 T 19 T20 T21 T22 T23 CTM/CFM Retire is automatic here unless: (1) No COLC packet (S=0) or (2) COLC packet is RD to device Da WR a1 retire (a1) MSK (a1) This RD gets the old data ROW2 ..ROW0 COL4 ..COL0 RD b1 retire (a1) MSK (a1) RD c1 tRTR D (a1) DQA8..0 DQB8..0 tCWD Transaction a: WR tCAC tCAC WR a1 tRTR DQA8..0 DQB8..0 This RD gets the new data D (a1) tCWD Transaction a: WR Transaction b: RD Transaction c: RD a1= {Da,Ba,Ca1} Q (b1) Q( a1= {Da,Ba,Ca1} b1= {Da,Ba,Ca1} c1= {Da,Ba,Ca1} Figure 17: Normal Retire (left) and Retire/Read Ordering (right) Figure 17 (right) shows the first of these side effects. The first COLC packet has a WR command which loads the address and data into the write buffer. The third COLC causes an automatic retire of the write buffer to the sense amp. The second and fourth COLC packets (which bracket the retire packet) contain RD commands with the same device, bank and column address as the original WR command. In other words, the same dualoct address that is written is read both before and after it is actually retired. The first RD returns the old dualoct value from the sense amp before it is overwritten. The second RD returns the new dualoct value that was just written. Figure 18 (left) shows the result of performing a RD command to the same device in the same COLC packet slot that would normally be used for the retire opera- Page 22 tion. The read may be to any bank and column address; all that matters is that it is to the same device as the WR command. The retire operation and MSK(a1) will be delayed by a time tPACKET as a result. If the RD command used the same bank and column address as the WR command, the old data from the sense amp would be returned. If many RD commands to the same device were issued instead of the single one that is shown, then the retire operation would be held off an arbitrarily long time. However, once a RD to another device or a WR or NOCOP to any device is issued, the retire will take place. Figure 18 (right) illustrates a situation in which the controller wants to issue a WR-WR-RD COLC packet sequence, with all commands addressed to the same device, but addressed to any combination of banks and columns. Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Write/Retire Examples - continued COLC packet. Therefore, it is required in this situation that the controller issue a NOCOP command in the third COLC packet, delaying the RD command by a time of tPACKET. This situation is explicitly shown in Table 12 for the cases in which tCCDELAY is equal to tRTR. The RD will prevent a retire of the first WR from automatically happening. But the first dualoct D(a1) in the write buffer will be overwritten by the second WR dualoct D(b1) if the RD command is issued in the third T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 CTM/CFM T0 T1 T2 T3 T4 T8 T9 T5 T6 T7 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 CTM/CFM The retire operation for a write can be held off by a read to the same device ROW2 ..ROW0 ROW2 ..ROW0 The controller must insert a NOCOP to retire (a1) to make room for the data (b1) in the write buffer tCAC COL4 ..COL0 WR a1 RD b1 tCAC COL4 ..COL0 retire (a1) MSK (a1) WR a1 WR b1 tRTR + tPACKET DQA8..0 DQB8..0 retire (a1) MSK (a1) RD c1 tRTR Q (b1) DQA8..0 D (a1) D (b1) D (a1) DQB8..0 tCWD Transaction a: WR Transaction b: RD tCWD Transaction a: WR Transaction b: WR Transaction c: RD a1= {Da,Ba,Ca1} b1= {Da,Bb,Cb1} a1= {Da,Ba,Ca1} b1= {Da,Bb,Cb1} c1= {Da,Bc,Cc1} Figure 18: Retire Held Off by Read (left) and Controller Forces WWR Gap (right) Figure 19 shows a possible result when a retire is held off for a long time (an extended version of Figure 18left). After a WR command, a series of six RD commands are issued to the same device (but to any combination of bank and column addresses). In the meantime, the bank Ba to which the WR command was originally directed is precharged, and a different row Rc is activated. When the retire is automatically performed, it is made to this new row, since the write T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 buffer only contains the bank and column address, not the row address. The controller can insure that this doesn’t happen by never precharging a bank with an unretired write buffer. Note that in a system with more than one RDRAM, there will never be more than two RDRAMs with unretired write buffers. This is because a WR command issued to one device automatically retires the write buffers of all other devices written a time tRTR before or earlier. T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM The retire operation puts the write data in the new row tRC ROW2 ..ROW0 ACT a0 PRER a2 ACT c0 tRAS COL4 ..COL0 WR a1 tRCD DQA8..0 DQB8..0 tRP RD b1 RD b2 RD b3 Transaction c: WR RD b5 RD b6 retire (a1) MSK (a1) tRTR D (a1) Transaction a: WR Transaction b: RD RD b4 tCWD tCAC a0 = {Da,Ba,Ra} a1 = {Da,Ba,Ca1} b1 = {Da,Bb,Cb1} b2 = {Da,Bb,Cb2} b4 = {Da,Bb,Cb4} b5 = {Da,Bb,Cb5} c0 = {Da,Ba,Rc} Q (b1) Q (b2) a2 = {Da,Ba} b3= {Da,Bb,Cb3} b6 = {Da,Bb,Cb6} Q (b3) Q (b4) Q (b5) WARNING This sequence is hazardous and must be used with caution Figure 19: Retire Held Off by Reads to Same Device, Write Buffer Retired to New Row INFINEON Technologies Version 1.0 Preliminary Information Page 23 Direct RAMBUS 72 Mbit (256kx18x16d) Interleaved Write - Example rather than the PRER command in an ROWR packet on the ROW pins. Figure 20 shows an example of an interleaved write transaction. Transactions similar to the one presented in Figure 16 are directed to non-adjacent banks of a single RDRAM. This allows a new transaction to be issued once every tRR interval rather than once every tRC interval (four times more often). The DQ data pin efficiency is 100% with this sequence. In this example, the first transaction is directed to device Da and bank Ba. The next three transactions are directed to the same device Da, but need to use different, non-adjacent banks Bb, Bc, Bd so there is no bank conflict. The fifth transaction could be redirected back to bank Ba without interference, since the first transaction would have completed by then (tRC has elapsed). Each transaction may use any value of row address (Ra, Rb, ..) and column address (Ca1, Ca2, Cb1, Cb2, ...). With two dualocts of data written per transaction, the COL, DQA, and DQB pins are fully utilized. Banks are precharged using the WRA autoprecharge option T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM Transaction e can use the same bank as transaction a tRC ROW2 ..ROW0 ACT a0 ACT b0 ACT c0 ACT d0 tRCD COL4 ..COL0 ACT e0 ACT f0 tRR WR z1 WRA z2 WR a1 WRA a2 WR b1 WRA b2 WR c1 WRA c2 WR d1 WR d2 WR e1 WR e2 MSK (y1) MSK (y2) MSK (z1) MSK (z2) MSK (a1) MSK (a2) MSK (b1) MSK (b2) MSK (c1) MSK (c2) MSK (d1) MSK (d2) tCWD DQA8..0 DQB8..0 D (x2) D (y1) D (y2) Transaction y: WR Transaction z: WR Transaction a: WR Transaction b: WR Transaction c: WR Transaction d: WR Transaction e: WR Transaction f: WR D (z1) D (z2) D (a1) y0 = {Da,Ba+4,Ry} z0 = {Da,Ba+6,Rz} a0 = {Da,Ba,Ra} b0 = {Da,Ba+2,Rb} c0 = {Da,Ba+4,Rc} d0 = {Da,Ba+6,Rd} e0 = {Da,Ba,Re} f0 = {Da,Ba+2,Rf} D (a2) D (b1) y1 = {Da,Ba+4,Cy1} z1 = {Da,Ba+6,Cz1} a1 = {Da,Ba,Ca1} b1 = {Da,Ba+2,Cb1} c1 = {Da,Ba+4,Cc1} d1 = {Da,Ba+6,Cd1} e1 = {Da,Ba,Ce1} f1 = {Da,Ba+2,Cf1} D (b2) D(c1) y2= {Da,Ba+4,Cy2} z2= {Da,Ba+6,Cz2} a2= {Da,Ba,Ca2} b2= {Da,Ba+2,Cb2} c2= {Da,Ba+4,Cc2} d2= {Da,Ba+6,Cd2} e2= {Da,Ba,Ce2} f2= {Da,Ba+2,Cf2} D (c2) D (d1) Q (d y3 = {Da,Ba+4} z3 = {Da,Ba+6} a3 = {Da,Ba} b3 = {Da,Ba+2} c3 = {Da,Ba+4} d3 = {Da,Ba+6} e3 = {Da,Ba} f3 = {Da,Ba+2} Figure 20: Interleaved Write Transaction with Two Dualoct Data Length Interleaved Read - Example Figure 21 shows an example of interleaved read transactions. Transactions similar to the one presented in Figure 15 are directed to non-adjacent banks of a single RDRAM. The address sequence is identical to the one used in the previous write example. The DQ data pins efficiency is also 100%. The only difference with the write example (aside from the use of the RD command rather than the WR command) is the use of the PREX command in a COLX packet to precharge the banks rather than the RDA command. This is done because the PREX is available for a readtransaction but is not available for a masked write transaction. Interleaved RRWW - Example Figure 22 shows a steady-state sequence of 2-dualoct RD/RD/WR/WR.. transactions directed to non-adja- Page 24 cent banks of a single RDRAM. This is similar to the interleaved write and read examples in Figure 20 and Figure 21 except that bubble cycles need to be inserted by the controller at read/write boundaries. The DQ data pin efficiency for the example in Figure 22 is 32/42 or 76%. If there were more RDRAMs on the Channel, the DQ pin efficiency would approach 32/34 or 94% for the two-dualoct RRWW sequence (this case is not shown). In Figure 22, the first bubble type tCBUB1 is inserted by the controller between a RD and WR command on the COL pins. This bubble accounts for the round-trip propagation delay that is seen by read data, and is explained in detail in Figure 4. This bubble appears on the DQA and DQB pins as tDBUB1 between a write data dualoct D and read data dualoct Q. This bubble also appears on the ROW pins as tRBUB1. Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T40 T41 T 38 T 39 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM Transaction e can use the same bank as transaction a tRC ROW2 ..ROW0 ACT a0 ACT b0 ACT c0 ACT d0 ACT e0 tRCD ACT f0 tRR COL4 ..COL0 RD z1 RD z2 PREX y3 RD a1 RD a2 PREX z3 DQA8..0 DQB8..0 Q (x2) Q (y1) Q (y2) Q (z1) RD b1 RD b2 PREX a3 RD c1 RD c2 PREX b3 RD d1 RDd2 PREX c3 RD e1 RD e2 PREX d3 Q (a1) Q (a2) Q (b1) Q (b2) Q (c1) Q (c2) Q (d1) tCAC Transaction y: RD Transaction z: RD Transaction a: RD Transaction b: RD Transaction c: RD Transaction d: RD Transaction e: RD Transaction f: RD Q (z2) y0 = {Da,Ba+4,Ry} z0 = {Da,Ba+6,Rz} a0 = {Da,Ba,Ra} b0 = {Da,Ba+2,Rb} c0 = {Da,Ba+4,Rc} d0 = {Da,Ba+6,Rd} e0 = {Da,Ba,Re} f0 = {Da,Ba+2,Rf} y1 = {Da,Ba+4,Cy1} z1 = {Da,Ba+6,Cz1} a1 = {Da,Ba,Ca1} b1 = {Da,Ba+2,Cb1} c1 = {Da,Ba+4,Cc1} d1 = {Da,Ba+6,Cd1} e1 = {Da,Ba,Ce1} f1 = {Da,Ba+2,Cf1} y2= {Da,Ba+4,Cy2} z2= {Da,Ba+6,Cz2} a2= {Da,Ba,Ca2} b2= {Da,Ba+2,Cb2} c2= {Da,Ba+4,Cc2} d2= {Da,Ba+6,Cd2} e2= {Da,Ba,Ce2} f2= {Da,Ba+2,Cf2} y3 = {Da,Ba+4} z3 = {Da,Ba+6} a3 = {Da,Ba} b3 = {Da,Ba+2} c3 = {Da,Ba+4} d3 = {Da,Ba+6} e3 = {Da,Ba} f3 = {Da,Ba+2} Figure 21: Interleaved Read Transaction with Two Dualoct Data Length The second bubble type tCBUB2 is inserted (as a NOCOP command) by the controller between a WR and RD command on the COL pins when there is a WR-WR-RD sequence to the same device. This bubble enables write data to be retired from the write buffer without being lost, and is explained in detail in T0 T4 T1 T2 T3 T5 T6 T7 T8 T 9 T 10 T 11 T12 T13 T 14 T 15 T16 T17 T 18 T 19 Figure 18. There would be no bubble if address c0 and address d0 were directed to different devices. This bubble appears on the DQA and DQB pins as tDBUB2 between a write data dualoct D and read data dualoct Q. This bubble also appears on the ROW pins as tRBUB2. T20 T21 T 22 T 23 T24 T25 T26 T 27 T28 T29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T42 T 43 T44 T45 T 46 T 47 CTM/CFM ROW2 ..ROW0 ACT a0 ACT b0 tCBUB2 COL4 ..COL0 RD z1 ACT c0 ACT d0 RD z2 RD a1 RD a2 PREX z3 WR b1 MSK (y2) D (y2) WRA b2 PREX a3 WR c1 WRA c2 NOCOP NOCOP MSK (b1) MSK (b2) MSK (c1) MSK (c2) RDd0 RDf tDBUB1 Q (z1) Transaction y: WR Transaction z: RD Transaction a: RD Transaction b: WR Transaction c: WR Transaction d: RD Transaction e: RD Transaction f: WR ACT e0 tCBUB2 tCBUB1 tDBUB2 tDBUB1 DQA8..0 DQB8..0 Transaction e can use the same bank as transaction a tRBUB2 tRBUB1 Q (z2) y0 = {Da,Ba+4,Ry} z0 = {Da,Ba+6,Rz} a0 = {Da,Ba,Ra} b0 = {Da,Ba+2,Rb} c0 = {Da,Ba+4,Rc} d0 = {Da,Ba+6,Rd} e0 = {Da,Ba,Re} f0 = {Da,Ba+2,Rf} Q (a1) Q (a2) y1 = {Da,Ba+4,Cy1} z1 = {Da,Ba+6,Cz1} a1 = {Da,Ba,Ca1} b1 = {Da,Ba+2,Cb1} c1 = {Da,Ba+4,Cc1} d1 = {Da,Ba+6,Cd1} e1 = {Da,Ba,Ce1} f1 = {Da,Ba+2,Cf1} D (b1) D (b2) D (c1) y2= {Da,Ba+4,Cy2} z2= {Da,Ba+6,Cz2} a2= {Da,Ba,Ca2} b2= {Da,Ba+2,Cb2} c2= {Da,Ba+4,Cc2} d2= {Da,Ba+6,Cd2} e2= {Da,Ba,Ce2} f2= {Da,Ba+2,Cf2} D (c2) y3 = {Da,Ba+4} z3 = {Da,Ba+6} a3 = {Da,Ba} b3 = {Da,Ba+2} c3 = {Da,Ba+4} d3 = {Da,Ba+6} e3 = {Da,Ba} f3 = {Da,Ba+2} Figure 22: Interleaved RRWW Sequence with Two Dualoct Data Length and two CMOS input/output pins SIO0 and SIO1. These provide serial access to a set of control registers Control Register Transactions The RDRAM has two CMOS input pins SCK and CMD INFINEON Technologies Version 1.0 Preliminary Information Page 25 Direct RAMBUS 72 Mbit (256kx18x16d) in the RDRAM. These control registers provide configuration information to the controller during the initialization process. They also allow an application to select the appropriate operating mode of the RDRAM. SIO1 are connected (in a daisy chain fashion) from one RDRAM to the next. In normal operation, the data on SIO0 is repeated on SIO1, which connects to SIO0 of the next RDRAM (the data is repeated from SIO1 to SIO0 for a read data packet). The controller connects to SIO0 of the first RDRAM. SCK (serial clock) and CMD (command) are driven by the controller to all RDRAMs in parallel. SIO0 and SCK T20 T4 T36 T52 T68 1 0 next transaction CMD 00000000...00000000 1111 0000 00000000...00000000 00000000...00000000 00000000...00000000 1 1111 0 SIO0 1 SRQ - SWR command SA SD SINT SA SD SINT 0 Each packet is repeated from SIO0 to SIO1 SIO1 SRQ - SWR command 1 0 Figure 23: Serial Write (SWR) Transaction to Control Register Write and read transactions are each composed of four packets, as shown in Figure 23 and Figure 24. Each packet consists of 16 bits, as summarized in Table 14 and Table 15. The packet bits are sampled on the falling edge of SCK. A transaction begins with a SRQ (Serial Request) packet. This packet is framed with a 11110000 pattern on the CMD input (note that the CMD bits are sampled on both the falling edge and the rising edge of SCK). The SRQ packet contains the SOP3..SOP0 (Serial Opcode) field, which selects the transaction type. The SDEV5..SDEV0 (Serial Device address) selects one of the 32 RDRAMs. If SBC (Serial Broadcast) is set, then all RDRAMs are selected. The SA (Serial Address) SCK T20 T4 packet contains a 12 bit address for selecting a control register. A write transaction has a SD (Serial Data) packet next. This contains 16 bits of data that is written into the selected control register. A SINT (Serial Interval) packet is last, providing some delay for any sideeffects to take place. A read transaction has a SINT packet, then a SD packet. This provides delay for the selected RDRAM to access the control register. The SD read data packet travels in the opposite direction (towards the controller) from the other packet types. The SCK cycle time will accomodate the total delay. T36 T52 T68 1 0 next transaction CMD 1111 0000 1 00000000...00000000 00000000...00000000 00000000...00000000 addressed RDRAM drives 0/SD15..SD0/0 on SIO0 SIO0 SRQ - SRD command SIO1 00000000...00000000 SA SINT 0 controller drives 0 on SIO0 0 First 3 packets are repeated from SIO0 to SIO1 SRQ - SRD command 1111 SD 1 0 0 non-addressed RDRAMs pass 0/SD15..SD0/0 from SIO1 to SIO0 SA SINT 0 SD 1 0 0 Figure 24: Serial Read (SRD) Transaction Control Register Page 26 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Control Register Packets T20 T4 1 Table 13 summarizes the formats of the four packet types for control register transactions. Table 14 summarizes the fields that are used within the packets. SCK 0 1 CMD Figure 25 shows the transaction format for the SETR, CLRR, and SETF commands. These transactions consist of a single SRQ packet, rather than four packets like the SWR and SRD commands. The same framing sequence on the CMD input is used, however. These commands are used during initialization prior to any control register read or write transactions. 00000000...00000000 1111 0000 0 1 SIO0 SRQ packet - SETR/CLRR/SETF 0 The packet is repeated from SIO0 to SIO1 SIO1 1 SRQ packet - SETR/CLRR/SETF 0 Figure 25: SETR, CLRR,SETF Transaction Table 13: Control Register Packet Formats SCK Cycle SIO0 or SIO1 for SRQ SIO0 or SIO1 for SA SIO0 or SIO1 for SINT SIO0 or SIO1 for SD SCK Cycle SIO0 or SIO1 for SRQ SIO0 or SIO1 for SA SIO0 or SIO1 for SINT SIO0 or SIO1 for SD 0 rsrv rsrv 0 SD15 8 SOP1 SA7 0 SD7 1 rsrv rsrv 0 SD14 9 SOP0 SA6 0 SD6 2 rsrv rsrv 0 SD13 10 SBC SA5 0 SD5 3 rsrv rsrv 0 SD12 11 SDEV4 SA4 0 SD4 4 rsrv SA11 0 SD11 12 SDEV3 SA3 0 SD3 5 SDEV5 SA10 0 SD10 13 SDEV2 SA2 0 SD2 6 SOP3 SA9 0 SD9 14 SDEV1 SA1 0 SD1 7 SOP2 SA8 0 SD8 15 SDEV0 SA0 0 SD0 Table 14: Field Description for Control Register Packets Field Description rsrv Reserved. Should be driven as “0” by controller. SOP3..SOP0 0000 - SRD. Serial read of control register {SA11..SA0} of RDRAM {SDEV5..SDEV0}. 0001 - SWR. Serial write of control register {SA11..SA0} of RDRAM {SDEV5..SDEV0}. 0010 - SETR. Set Reset bit, all control registers assume their reset values.a 16 tSCYCLE delay until CLRR command. 0100 - SETF. Set fast (normal) clock mode. 4 tSCYCLE delay until next command. 1011 - CLRR. Clear Reset bit, all control registers retain their reset values.a 4 t SCYCLE delay until next command. 1111 - NOP. No serial operation. 0011, 0101-1010, 1100-1110 - RSRV. Reserved encodings. SDEV5..SDEV0 Serial device. Compared to SDEVID5..SDEVID0 field of INIT control register field to select the RDRAM to which the transaction is directed. SBC Serial broadcast. When set, RDRAMs ignore {SDEV5..SDEV0} for RDRAM selection. SA11..SA0 Serial address. Selects which control register of the selected RDRAM is read or written. SD15..SD0 Serial data. The 16 bits of data written to or read from the selected control register of the selected RDRAM. a. The SETR and CLRR commands must always be applied in two successive transactions to RDRAMs; i.e. they may not be used in isolation. This is called “SETR/CLRR Reset”. INFINEON Technologies Version 1.0 Preliminary Information Page 27 Direct RAMBUS 72 Mbit (256kx18x16d) Initialization T16 T0 1 o 3.3 Write TEST77 Register - The TEST77 register must be explicitly written with zeros before any other registers are read or written. o 3.4 Write TCYCLE Register - The TCYCLE register is written with the cycle time tCYCLE of the CTM clock (for Channel and RDRAMs) in units of 64ps. The tCYCLE value is determined in stage 1.0. o 3.5 Write SDEVID Register - The SDEVID (serial device identification) register of each RDRAM is written with a unique address value so that directed SIO read and write transactions can be performed. This address value increases from 0 to 31 according to the distance an RDRAM is from the ASIC component on the SIO bus (the closest RDRAM is address 0). o 3.6 Write DEVID Register - The DEVID (device identification) register of each RDRAM is written with a unique address value so that directed memory read and write transactions can be performed. This address value increases from 0 to 31. The DEVID value is not necessarily the same as the SDEVID value. RDRAMs are sorted into regions of the same core configuration (number of bank, row, and column address bits and core type). o 3.7 Write PDNX,PDNXA Registers - The PDNX and PDNXA registers are written with values that are used to measure the timing intervals connected with an exit from the PDN (powerdown) power state. o 3.8 Write NAPX Register - The NAPX register is written with values that are used to measure the timing intervals connected with an exit from the NAP power state. o 3.9 Write TPARM Register - The TPARM register is written with values which determine the time interval between a COL packet with a memory read command and the Q packet with the read data on the Channel. The values written set each RDRAM to the minimum value permitted for the system. This will be adjusted later in stage 6.0. o 3.10 Write TCDLY1 Register - The TCDLY1 register is written with values which determine the time interval between a COL packet with a memory read command and the Q packet with the read data on the Channel. The values written set each RDRAM to the minimum value permitted for the system. This will be adjusted later in stage 6.0. SCK 0 1 CMD 00001100 00000000...00000000 0 1 SIO0 0000000000000000 The packet is repeated from SIO0 to SIO1 SIO1 0 1 0000000000000000 0 Figure 26: SIO Reset Sequence Initialization refers to the process that a controller must go through after power is applied to the system or the system is reset. The controller prepares the RDRAM sub-system for normal Channel operation by (primarily) using a sequence of control register transactions on the serial CMOS pins. The following steps outline the sequence seen by the various memory subsystem components (including the RDRAM components) during initialization. This sequence is available in the form of reference code. Contact Rambus Inc. for more information. 1.0 Start Clocks - This step calculates the proper clock frequencies for PClk (controller logic), SynClk (RAC block), RefClk (DRCG component), CTM (RDRAM component), and SCK (SIO block). 2.0 RAC Initialization - This step causes the INIT block to generate a sequence of pulses which resets the RAC, performs RAC maintainance operations, and measures timing intervals in order to ensure clock stability. 3.0 RDRAM Initialization - This stage performs most of the steps needed to initialize the RDRAMs. The rest are performed in stages 5.0, 6.0, and 7.0. All of the steps in 3.0 are carried out through the SIO block interface. o 3.1/3.2 SIO Reset - This reset operation is performed berore any SIO control register read or write transactions. It clears six registers (TEST34, CCA, CCB, SKIP, TEST78, and TEST79) and places the INIT register into a special state (all bits cleared except SKP and SDEVID fields are set to ones). Page 28 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) o 3.11 Write TFRM Register - The TFRM register is written with a value that is related to the tRCD parameter for the system. The tRCD parameter is the time interval between a ROW packet with an activate command and the COL packet with a read or write command. o 3.12 SETR/CLRR - Each RDRAM is given a SETR command and a CLRR command through the SIO block. This sequence performs a second reset operation on the RDRAMs. o 3.13 Write CCA and CCB Registers - These registers are written with a value halfway between their minimum and maximum values. This shortens the time needed for the RDRAMs to reach their steady-state current control values in stage 5.0. o 3.14 Powerdown Exit - The RDRAMs are in the PDN power state at this point. A broadcast PDNExit command is performed by the SIO block to place the RDRAMs in the RLX (relax) power state in which they are ready to receive ROW packets. o 3.15 SETF - Each RDRAM is given a SETF command through the SIO block. One of the operations performed by this step is to generate a value for the AS (autoskip) bit in the SKIP register and fix the RDRAM to a particular read domain. 4.0 Controller Configuration- This stage initializes the controller block. Each step of this stage will set a field of the ConfigRMC[63:0] bus to the appropriate value. Other controller implementations will have similar initialization requirements, and this stage may be used as a guide. o 4.1 Initial Read Data Offset- The ConfigRMC bus is written with a value which determines the time interval between a COL packet with a memory read command and the Q packet with the read data on the Channel. The value written sets RMC.d1 to the minimum value permitted for the system. This will be adjusted later in stage 6.0. o 4.2 Configure Row/Column Timing - This step determines the values of the tRAS,MIN, tRP,MIN, tRC,MIN, tRCD,MIN, tRR,MIN, and tPP,MIN RDRAM timing parameters that are present in the system. The ConfigRMC busis written with values that will be compatible with all RDRAM devices that are present. o that are present in the system. The ConfigRMC bus is written with a value that will be compatible with all RDRAM devices that are present. o 4.4 Set Current Control Interval - This step determines the values of the tCCTRL,MAX RDRAM timing parameter that are present in the system. The ConfigRMC bus is written with a value that will be compatible with all RDRAM devices that are present. o 4.5 Set Slew Rate Control Interval - This step determines the values of the tTEMP,MAX RDRAM timing parameter that are present in the system. The ConfigRMC bus is written with a value that will be compatible with all RDRAM devices that are present. o 4.6 Set Bank/Row/Col Address Bits - This step determines the number of RDRAM bank, row, and column address bits that are present in the system. It also determines the RDRAM core types (independent, doubled, or split) that are present. The ConfigRMC bus is written with a value that will be compatible with all RDRAM devices that are present. 5.0 RDRAM Current Control - This step causes the INIT block to generate a sequence of pulses which performs RDRAM maintainance operations. 6.0 RDRAM Core, Read Domain Initialization- This stage completes the RDRAM initialization o 6.1 RDRAM Core Initialization - A sequence of 192 memory refresh transactions is performed in order to place the cores of all RDRAMs into the proper operating state. o 6.2 RDRAM Read Domain Initialization - A memory write and memory read transaction is performed to each RDRAM to determine which read domain each RDRAM occupies. The programmed delay of each RDRAM is then adjusted so the total RDRAM read delay (propagation delay plus programmed delay) is constant. The TPARM and TCDLY1 registers of each RDRAM are rewritten with the appropriate read delay values. The ConfigRMC bus is also rewritten with an updated value. 7.0 Other RDRAM Register Fields - This stage rewrites the INIT register with the final values of the LSR, NSR, and PSR fields. 4.3 Set Refresh Interval - This step determines the values of the tREF,MAX RDRAM timing parameter INFINEON Technologies Version 1.0 Preliminary Information Page 29 Direct RAMBUS 72 Mbit (256kx18x16d) In essence, the controller must read all the read-only configuration registers of all RDRAMs (or it must read the SPD device present on each RIMM), it must process this information, and then it must write all the readwrite registers to place the RDRAMs into the proper operating mode. Initialization Note [1]: During the initialization process, it is necessary for the controller to perform 128 current control operations (3xCAL, 1xCAL/SAM) and one temperature calibrate operation (TCEN/TCAL) after reset or after powerdown (PDN) exit. Initialization Note [2]: There are two classes of 64/72Mbit RDRAM. They are distinguished by the “S28IECO” bit in the SPD. The behavior of the RDRAM at initialization is slightly different for the two types: S28IECO=0: Upon powerup the device enters ATTN state. The serial operations SETR, CLRR, and SETF are performed without requiring a SDEVID match of the SBC bit (broadcast) to be set. S28IECO=1: Upon powerup the device enters PDN state. The serial operations SETR, CLRR, and SETF require a SDEVID match. See the document detailing the reference initialization procedure for more information on how to handle this in a system. Initialization Note [3]: After the step of equalizing the total read delay of each RDRAM has been completed (i.e. after the TCDLY0 and TCDLY1 fields have been written for the final time), a single final memory read transaction should be made to each RDRAM in order to ensure that the output pipeline stages have been cleared. Initialization Note [4]: The SETF command (in the serial SRQ packet) should only be issued once during the Initialization process, as should the SETR and CLRR commands. Initialization Note [5]: The CLRR command (in the serial SRQ packet) leaves some of the contents of the memory core in an indeterminate state. Control Register Summary Table 15 summarizes the RDRAM control registers. Detail is provided for each control register in Figure 27 through Figure 43. Read-only bits which are shaded gray are unused and return zero. Read-write bits which are shaded gray are reserved and should always be written with zero. The RIMM SPD Application Note (DL-0054) describes additional read-only configuration registers which are present on Direct RIMMs. The state of the register fields are potentially affected by the IO Reset operation or the SETR/CLRR operation. This is indicated in the text accompanying each register diagram. Table 15: Control Register Summary SA11..SA0 Register Field read-write/ read-only Description 02116 INIT SDEVID read-write, 6 bits Serial device ID. Device address for control register read/write. PSX read-write, 1 bit Power select exit. PDN/NAP exit with device addr on DQA5..0. 02216 TEST34 02316 CNFGA Page 30 SRP read-write, 1 bit SIO repeater. Used to initialize RDRAM. NSR read-write, 1 bit NAP self-refresh. Enables self-refresh in NAP mode. PSR read-write, 1 bit PDN self-refresh. Enables self-refresh in PDN mode. LSR read-write, 1 bit Low power self-refresh. Enables low power self-refresh. TEN read-write, 1 bit Temperature sensing enable. TSQ read-write, 1 bit Temperature sensing output. DIS read-write, 1 bit RDRAM disable. TEST34 read-write, 16 bits Test register. Do not read or write after SIO reset. REFBIT read-only, 3 bit Refresh bank bits. Used for multi-bank refresh. DBL read-only, 1 bit Double. Specifies doubled-bank architecture MVER read-only, 6 bit Manufacturer version. Manufacturer identification number. PVER read-only, 6 bit Protocol version. Specifies version of Direct protocol supported. Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Table 15: Control Register Summary SA11..SA0 Register Field read-write/ read-only Description 02416 CNFGB BYT read-only, 1 bit Byte. Specifies an 8-bit or 9-bit byte size. DEVTYP read-only, 3 bit Device type. Device can be RDRAM or some other device category. SPT read-only, 1 bit Split-core. Each core half is an individual dependent core. CORG read-only, 6 bit Core organization. Bank, row, column address field sizes. SVER read-only, 6 bit Stepping version. Mask version number. 04016 DEVID DEVID read-write, 5 bits Device ID. Device address for memory read/write. 04116 REFB REFB read-write, 4 bits Refresh bank. Next bank to be refreshed by self-refresh. 04216 REFR REFR read-write, 9 bits Refresh row. Next row to be refreshed by REFA, self-refresh. 04316 CCA CCA read-write, 7 bits Current control A. Controls IOL output current for DQA. ASYMA read-write, 2 bits Asymmetry control. Controls asymmetry of V OL/VOH swing for DQA. 04416 CCB CCB read-write, 7 bits Current control B. Controls I OL output current for DQB. ASYMB read-write, 2 bits Asymmetry control. Controls asymmetry of V OL/VOH swing for DQB. NAPXA read-write, 5 bits NAP exit. Specifies length of NAP exit phase A. NAPX read-write, 5 bits NAP exit. Specifies length of NAP exit phase A + phase B. DQS read-write, 1 bits DQ select. Selects CMD framing for NAP/PDN exit. 04516 NAPX 04616 PDNXA PDNXA read-write, 13 bits PDN exit. Specifies length of PDN exit phase A. 04716 PDNX PDNX read-write, 13 bits PDN exit. Specifies length of PDN exit phase A + phase B. 04816 TPARM TCAS read-write, 2 bits tCAS-C core parameter. Determines tOFFP datasheet parameter. TCLS read-write, 2 bits tCLS-C core parameter. Determines tCAC and tOFFP parameters. TCDLY0 read-write, 3 bits tCDLY0-C core parameter. Programmable delay for read data. TFRM read-write, 4 bits tFRM-C core parameter. Determines ROW-COL packet framing interval. 04916 TFRM 04a16 TCDLY1 TCDLY1 read-write, 3 bits tCDLY1-C core parameter. Programmable delay for read data. 04c16 TCYCLE TCYCLE read-write, 14 bits tCYCLE datasheet parameter. Specifies cycle time in 64ps units. 04b16 SKIP AS read-only, 1 bit Autoskip value established by the SETF command. MSE read-write, 1 bit Manual skip enable. Allows the MS value to override the AS value. MS read-write, 1 bit Manual skip value. 04d16- TEST77 TEST77 read-write, 16 bits Test register. Write with zero after SIO reset. 04e16- TEST78 TEST78 read-write, 16 bits Test register. Do not read or write after SIO reset. 04f16- TEST79 TEST79 read-write, 16 bits Test register. Do not read or write after SIO reset. 08016 - 0ff16 reserved reserved vendor-specific Vendor-specific test registers. Do not read or write after SIO reset. INFINEON Technologies Version 1.0 Preliminary Information Page 31 Direct RAMBUS 72 Mbit (256kx18x16d) . Control Register: INIT 15 14 13 12 11 10 9 0 8 7 Address: 02116 6 SDE VID DIS TSQ TEN LSR PSR NSR SRP PSX 5 5 4 0 SDEVID4..SDEVID0 3 2 1 0 . Read/write register. Reset values are undefined except as affected by SIO Reset as noted below. SETR/CLRR Reset does not affect this register. SDEVID5..0 - Serial Device Identification. Compared to SDEV5..0 serial address field of serial request packet for register read/write transactions. This determines which RDRAM is selected for the register read or write operation. SDEVID resets to 3f 16. PSX - Power Exit Select. PDN and NAP are exited with (=0) or without (=1) a device address on the DQA5..0 pins. PDEV5 (on DQA5) selectes broadcast (1) or directed (0) exit. For a directed exit, PDEV4..0 (on DQA4..0) is compared to DEVID4..0 to select a device. SRP - SIO Repeater. Controls value on SIO1; SIO1=SIO0 if SRP=1, SIO1=1 if SRP=0. SRP resets to 1. NAP Self-Refresh. NSR=1 enables self-refresh in NAP mode. NSR can’t be set while in NAP mode. NSR resets to 0. PDN Self-Refresh. PSR=1 enables self-refresh in PDN mode. PSR can’t be set while in PDN mode. PSR resets to 0. Low Power Self-Refresh. LSR=1 enables longer self-refresh interval. The self-refresh supply current is reduced. LSR resets to 0. Temperature Sensing Enable. TEN=1 enables temperature sensing circuitry, permitting the TSQ bit to be read to determine if a thermal trip point has been exceeded. TEN resets to 0. Temperature Sensing Output. TSQ=1 when a temperature trip point has been exceeded, TSQ=0 when it has not. TSQ is available during a current control operation (see Figure 51). RDRAM Disable. DIS=1 causes RDRAM to ignore NAP/PDN exit sequence, DIS=0 permits normal operation. This mechanism disables an RDRAM. DIS resets to 0. Figure 27: INIT Register Control Register: CNFGA 15 14 13 12 11 10 9 0 0 PVER5..0 0 =0000001 0 0 0 8 7 6 5 MVER5..0 0= mmmmmm 0 0 0 Address: 02316 Read-only register. 4 REFBIT2..0 - Refresh Bank Bits. Specifies the number of bank address bits used by REFA and REFP commands. Permits multi-bank refresh in future RDRAMs. 0 3 2 1 0 DBL REFBIT2..0 01 0 = 0100 0 DBL - Doubled-Bank. DBL=1 means the device uses a doubled-bank architecture with adjacent-bank dependency. DBL=0 means no dependency. MVER5..0 - Manufacturer Version. Specifies the manufacturer identification number. Note: In RDRAMs with protocol version 1 PVER[5:0] = 000001, the range of the PDNX field (PDNX[2:0] in the PDNX register) may not be large enough to specify the location of the restricted interval in Figure 47. In this case, the effective tS4 parameter must increase and no row or column packets may overlap the restricted interval. See Figure 47 and Table 19. PVER5..0 - Protocol Version. Specifies the Direct Protocol version used by this device: 0 - Compliant with version 0.62. 1 - Compliant with version 0.7 through this version. 2 to 63 - Reserved. Figure 28: CNFGA Register Page 32 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Control Register: CNFGB 15 14 13 12 11 10 9 0 0 SVER5..0 0 =0ssssss 0 0 0 8 7 Address: 02416 6 CORG4..0 0 = xxxxx 0 0 5 0 4 3 2 1 0 SPT DEVTYP2..0 BYT 00 0 = 0000 0 0B .. Read-only register. BYT - Byte width. B=1 means the device reads and writes 9-bit memory bytes. B=0 means 8 bits. DEVTYP2..0 - Device type. DEVTYP = 000 means that this device is an RDRAM. SPT - Split-core. SPT=1 means the core is split, SPT=0 means it is not. CORG4..0 - Core organization. This field specifies the number of bank (3, 4, 5, or 6 bits), row (9, 10, 11, or 12 bits), and column (5, 6, or 7 bits) address bits. The encoding of this field will be specified in a later version of this document. SVER5..0 - Stepping version. Specifies the mask version number of this device. Figure 29: CNFGB Register Control Register: TEST34 Address: 02216 Control Register: DEVID Address: 04016 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 8 7 6 5 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 4 3 2 1 0 DEVID4..DEVID0 Read/write register. Reset value of TEST34 is zero (from SIO Reset) This register are used for testing purposes. It must not be read or written after SIO Reset. Read/write register. Reset value is undefined. Device Identification register. DEVID4..DEVID0 is compared to DR4..DR0, DC4..DC0, and DX4..DX0 fields for all memory read or write transactions. This determines which RDRAM is selected for the memory read or write transaction. Figure 30: TEST Register Figure 31: DEVID Register INFINEON Technologies Version 1.0 Preliminary Information Page 33 Direct RAMBUS 72 Mbit (256kx18x16d) Control Register: REFB 15 14 13 12 11 10 9 8 7 6 5 4 0 0 0 0 0 0 0 0 0 0 0 0 Control Register: REFR Address: 04116 3 2 1 0 REFB3..REFB0 15 14 13 12 11 10 9 0 0 0 0 0 0 8 7 Address: 04216 6 0 5 4 3 2 1 0 REFR8..REFR0 Read/write register. Reset value is zero (from SETR/CLRR). Refresh Bank register. REFB3..REFB0 is the bank that will be refreshed next during self-refresh. REFB3..0 is incremented after each self-refresh activate and precharge operation pair. Read/write register. Reset value is zero (from SETR/CLRR). Refresh Row register. REFR8..REFR0 is the row that will be refreshed next by the REFA command or by self-refresh. REFR8..0 is incremented when BR3..0=1111 for the REFA command. REFR8..0 is incremented when REFB3..0=1111 for self-refresh. Figure 32: REFB Register Figure 34: REFR Register Control Register: CCA 15 14 13 12 11 10 9 0 0 0 0 0 0 0 8 7 Control Register: CCB Address: 04316 6 ASYMA 0 0 .0 5 4 3 2 1 0 15 14 13 12 11 10 9 0 CCA6..CCA0 0 0 0 0 0 0 8 7 ASYMB 0 0 ..0 Address: 04416 6 5 4 3 2 1 0 CCB6..CCB0 Read/write register. Reset value is zero (SETR/CLRR or SIO Reset). CCA6..CCA0 - Current Control A. Controls the IOL output current for the DQA8..DQA0 pins. Read/write register. Reset value is zero (SETR/CLRR or SIO Reset). CCB6..CCB0 - Current Control B. Controls the IOL output current for the DQB8..DQB0 pins. ASYMB0 control the asymmetry of the VOL/V OH voltage swing about the VREF reference voltage for the DQA8..0 pins. ASYMB0 control the asymmetry of the VOL/VOH voltage swing about the V REF reference voltage for the DQB8..0 pins. Figure 33: CCA Register Figure 35: CCB Register Page 34 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Control Register: NAPX 15 14 13 12 11 10 9 0 0 0 0 0 DQS 0 8 7 Address: 04516 6 5 4 NAPX4..0 3 2 1 0 NAPXA4..0 . Read/write register. Reset value is undefined Note - tSCYCLE is tCYCLE1 (SCK cycle time). NAPXA4..0 - Nap Exit Phase A. This field specifies the number of SCK cycles during the first phase for exiting NAP mode. It must satisfy: NAPXA•tSCYCLE ≥ tNAPXA,MAX Do not set this field to zero. NAPX4..0 - Nap Exit Phase A plus B. This field specifies the number of SCK cycles during the first plus second phases for exiting NAP mode. It must satisfy: NAPX•tSCYCLE ≥ NAPXA•tSCYCLE+tNAPXB,MAX Do not set this field to zero. DQS - DQ Select. This field specifies the number of SCK cycles (0 => 0.5 cycles, 1 => 1.5 cycles) between the CMD pin framing sequence and the device selection on DQ5..0. See Figure 48 - This field must be written with a “1” for this RDRAM. Figure 36: NAPX Register Control Register: PDNXA 15 14 13 12 11 10 9 0 0 0 8 7 Address: 04616 6 5 4 3 2 1 0 Control Register: PDNX 15 14 13 12 11 10 9 0 PDNXA12..0 0 0 8 7 Address: 04716 6 5 4 3 2 1 0 PDNX12..0 Read/write register. Reset value is undefined PDNXA4..0 - PDN Exit Phase A. This field specifies the number of (64•SCK cycle) units during the first phase for exiting PDN mode. It must satisfy: PDNXA•64•tSCYCLE ≥ tPDNXA,MAX Do not set this field to zero. Note - only PDNXA5..0 are implemented. Note - tSCYCLE is tCYCLE1 (SCK cycle time). Read/write register. Reset value is undefined PDNX4..0 - PDN Exit Phase A plus B. This field specifies the number of (256•SCK cycle) units during the first plus second phases for exiting PDN mode. It should satisfy: PDNX•256•tSCYCLE ≥ PDNXA•64•tSCYCLE+ tPDNXB,MAX If this cannot be satisfied, then the maximum PDNX value should be written, and the tS4/tH4 timing window will be modified (see Figure 49). Do not set this field to zero. Note - only PDNX2..0 are implemented. Note - tSCYCLE is t CYCLE1 (SCK cycle time). Figure 37: PDNXA Register Figure 38: PDNX Register INFINEON Technologies Version 1.0 Preliminary Information Page 35 Direct RAMBUS 72 Mbit (256kx18x16d) Control Register: TPARM Address: 04816 15 14 13 12 11 10 9 8 7 6 0 0 0 0TCDLY0 0 0 0 0 0 0 0 0 . The equations relating the core parameters to the datasheet parameters follow: tCAS-C = 2•tCYCLE tCLS-C = 2•tCYCLE tCPS-C = 1•tCYCLE Not programmable 5 4 3 2 TCLS 1 0 TCAS Read/write register. Reset value is undefined. TCAS1..0 - Specifies the tCAS-C core parameter in tCYCLE units. This should be “10” (2•tCYCLE). tOFFP = tCPS-C + tCAS-C + tCLS-C - 1•tCYCLE = 4•tCYCLE tRCD = tRCD-C + 1•tCYCLE - tCLS-C = tRCD-C - 1•tCYCLE TCLS1..0 - Specifies the tCLS-C core parameter in tCYCLE units. Should be “10” (2•tCYCLE). TCDLY0 - Specifies the tCDLY0-C core parameter in tCYCLE units. This adds a programmable delay to Q (read data) packets, permitting round trip read delay to all devices to be equalized. This field may be written with the values “010” (2•tCYCLE) through “101” (5•tCYCLE). tCAC = 3•tCYCLE + tCLS-C + tCDLY0-C + tCDLY1-C (see table below for programming ranges) TCDLY0 tCDLY0-C TCDLY1 tCDLY1-C tCAC @ tCYCLE = 3.3ns tCAC @ tCYCLE = 2.5ns 010 2•tCYCLE 000 0•tCYCLE 7•tCYCLE not allowed 011 3•tCYCLE 000 0•tCYCLE 8•tCYCLE 8•tCYCLE 011 3•tCYCLE 001 1•tCYCLE 9•tCYCLE 9•tCYCLE 011 3•tCYCLE 010 2•tCYCLE 10•tCYCLE 10•tCYCLE 100 4•tCYCLE 010 2•tCYCLE 11•tCYCLE 11•tCYCLE 101 5•tCYCLE 010 2•tCYCLE 12•tCYCLE 12•tCYCLE Figure 39: TPARM Register Control Register: TFRM Address: 04916 15 14 13 12 11 10 9 8 7 6 5 4 0 0 0 0 0 0 0 0 0 0 0 0 3 2 1 0 TFRM3..0 Control Register: TCDLY1 Address: 04a16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 0 0 0 0 0 0 0 0TCDLY1 0 0 0 0 0 0 1 0 Read/write register. Reset value is undefined. TFRM3..0 - Specifies the position of the framing point in tCYCLE units. This value must be greater than or equal to the tFRM,MIN parameter. This is the minimum offset between a ROW packet (which places a device at ATTN) and the first COL packet (directed to that device) which must be framed. This field may be written with the values “0111” (7•tCYCLE) through “1010” (10•tCYCLE). TFRM is usually set to the value which matches the largest tRCD,MIN parameter (modulo 4•tCYCLE) that is present in an RDRAM in the memory system. Thus, if an RDRAM with tRCD,MIN = 11•tCYCLE were present, then TFRM would be programmed to 7•tCYCLE. Read/write register. Reset value is undefined. TCDLY1 - Specifies the value of the tCDLY1-C core parameter in tCYCLE units. This adds a programmable delay to Q (read data) packets, permitting round trip read delay to all devices to be equalized. This field may be written with the values “000” (0•tCYCLE) through “010” (2•tCYCLE). Refer to Figure 39 for more details. Figure 40: TFRM Register Figure 41: TRDLY Register Page 36 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Control Register: SKIP Address: 04b16 Control Register: TCYCLE 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 15 14 13 12 11 10 9 0 0 0 0 0 0 0 0 0 0 0 0 0 AS 0 MSE 0 MS 0 0 Read/write register (except AS field). Reset value is zero (SIO Reset). AS - Autoskip. Read-only value determined by autoskip circuit and stored when SETF serial command is received by RDRAM during initialization. In figure 58, AS=1 corresponds to the early Q(a1) packet and AS=0 to the Q(a1) packet one tCYCLE later for the four uncertain cases. MSE - Manual skip enable (0=auto, 1=manual). MS - Manual skip (MS must be 1 when MSE=1).> During initialization, the RDRAMs at the furthest point in the fifth read domain may have selected the AS=0 value, placing them at the closest point in a sixth read domain. Setting the MSE/MS fields to 1/1 overrides the autoskip value and returns them to the furthest point of the fifth read domain. 0 Address: 04d16 Control Register: TEST78 Address: 04e16 Control Register: TEST79 Address: 04f16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 6 5 4 3 2 1 0 TCYCLE13..TCYCLE0 Figure 44: TCYCLE Register Control Register: TEST77 0 7 Read/write register. Reset value is undefined TCYCLE13..0 - Specifies the value of the tCYCLE datasheet parameter in 64ps units. For the tCYCLE,MIN of 2.5ns (2500ps), this field should be written with the value “0002716” (39•64ps). Figure 42: SKIP Register 0 8 Address: 04c16 Read/write registers. Reset value of TEST78,79 is zero ( SIO Reset). Do not read or write TEST78,79 after SIO reset. TEST77 must be written with zero after SIO reset. These registers must only be used for testing purposes. Figure 43: TEST Registers INFINEON Technologies Version 1.0 Preliminary Information Page 37 Direct RAMBUS 72 Mbit (256kx18x16d) Power State Management long exit latency because the TCLK/RCLK block must resynchronize itself to the external clock signal. Table 16 summarizes the power states available to a Direct RDRAM. In general, the lowest power states have the longest operational latencies. For example, the relative power levels of PDN state and STBY state have a ratio of about 1:110, and the relative access latencies to get read data have a ratio of about 250:1. PDN state is the lowest power state available. The information in the RDRAM core is usually maintained with self-refresh; an internal timer automatically refreshes all rows of all banks. PDN has a relatively NAP state is another low-power state in which either self-refresh or REFA-refresh are used to maintain the core. See “Refresh” on page 42 for a description of the two refresh mechanisms. NAP has a shorter exit latency than PDN because the TCLK/RCLK block maintains its synchronization state relative to the external clock signal at the time of NAP entry. This imposes a limit (tNLIMIT) on how long an RDRAM may remain in NAP state before briefly returning to STBY or ATTN to update this synchronization state. Table 16: Power State Summary Power State Description Blocks consuming power Power State Description Blocks consuming power PDN Powerdown state. Self-refresh NAP Nap state. Similar to PDN except lower wake-up latency. Self-refresh or REFA-refresh TCLK/RCLK-Nap STBY Standby state. Ready for ROW packets. REFA-refresh TCLK/RCLK ROW demux receiver ATTN Attention state. Ready for ROW and COL packets. REFA-refresh TCLK/RCLK ROW demux receiver COL demux receiver ATTNR Attention read state. Ready for ROW and COL packets. Sending Q (read data) packets. REFA-refresh TCLK/RCLK ROW demux receiver COL demux receiver DQ mux transmitter Core power ATTNW Attention write state. Ready for ROW and COL packets. Ready for D (write data) packets. REFA-refresh TCLK/RCLK ROW demux receiver COL demux receiver DQ demux receiver Core power Figure 45 summarizes the transition conditions needed for moving between the various power states. Note that NAP and PDN have been divided into two substates (NAP-A/NAP-S and PDN-A/PDN-S) to account for the fact that a NAP or PDN exit may be made to either ATTN or STBY states. At initialization, the SETR/CLRR Reset sequence will put the RDRAM into PDN-S state. The PDN exit sequence involves an optional PDEV specification and bits on the CMD and SIOIN pins. Once the RDRAM is in STBY, it will move to the ATTN/ATTNR/ATTNW states when it receives a nonbroadcast ROWA packet or non-broadcast ROWR packet with the ATTN command. The RDRAM returns to STBY from these three states when it receives a RLX command. Alternatively, it may enter NAP or PDN state from ATTN or STBY states with a NAPR or PDNR command in an ROWR packet. The PDN or NAP exit sequence involves an optional PDEV specification and bits on the CMD and SIO0 pins. The Page 38 RDRAM returns to the ATTN or STBY state it was originally in when it first entered NAP or PDN. An RDRAM may only remain in NAP state for a time tNLIMIT. It must periodically return to ATTN or STBY. The NAPRC command causes a napdown operation if the RDRAM’s NCBIT is set. The NCBIT is not directly visible. It is undefined on reset. It is set by a NAPR command to the RDRAM, and it is cleared by an ACT command to the RDRAM. It permits a controller to manage a set of RDRAMs in a mixture of power states. STBY state is the normal idle state of the RDRAM. In this state all banks and sense amps have usually been left precharged and ROWA and ROWR packets on the ROW pins are being monitored. When a non-broadcast ROWA packet or non-broadcast ROWR packet (with the ATTN command) packet addressed to the RDRAM is seen, the RDRAM enters ATTN state (see the right side of Figure 46). This requires a time tSA during which the RDRAM activates the specified row of the specified bank. A time TFRM•tCYCLE after the ROW Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) packet, the RDRAM will be able to frame COL packets (TFRM is a control register field - see Figure 40). Once in ATTN state, the RDRAM will automatically transition to the ATTNW and ATTNR states as it receives WR and RD commands. automatic The RDRAM may be in ATTN or STBY state when the NAPR command is issued. When NAP state is exited, the RDRAM will return to the original starting state (ATTN or STBY). If it is in ATTN state and a RLXR command is specified with NAPR, then the RDRAM will return to STBY state when NAP is exited. automatic automatic automatic ATTNW automatic automatic ATTNR ATTN RLX tNLIMIT NAPR • RLXR NAP-A PDEV.CMD•SIO0 NAP NAPR • RLXR NAP-S PDEV.CMD•SIO0 PDNR • RLXR PDN-A PDEV.CMD•SIO0 PDN PDNR • RLXR NAPR PDNR ATTN PDN-S PDEV.CMD•SIO0 SETR/CLRR STBY Notation: SETR/CLRR - SETR/CLRR Reset sequence in SRQ packets PDNR - PDNR command in ROWR packet NAPR - NAPR command in ROWR packet RLXR - RLX command in ROWR packet RLX - RLX command in ROWR,COLC,COLX packets SIO0 - SIO0 input value PDEV.CMD - (PDEV=DEVID)•(CMD=01) ATTN - ROWA packet (non-broadcast) or ROWR packet (non-broadcast) with ATTN command Figure 45: Power State Transition Diagram Once the RDRAM is in ATTN, ATTNW, or ATTNR states, it will remain there until it is explicitly returned to the STBY state with a RLX command. A RLX command may be given in an ROWR, COLC , or COLX packet (see the left side of Figure 46). It is usually given after all banks of the RDRAM have been precharged; if other banks are still activated, then the RLX command would probably not be given. If a broadcast ROWA packet or ROWR packet (with the ATTN command) is received, the RDRAM’s power state doesn’t change. If a broadcast ROWR packet with RLXR command is received, the RDRAM goes to STBY. INFINEON Technologies Version 1.0 Figure 47 shows the NAP entry sequence (left). NAP state is entered by sending a NAPR command in a ROW packet. A time tASN is required to enter NAP state (this specification is provided for power calculation purposes). The clock on CTM/CFM must remain stable for a time tCD after the NAPR command. Figure 47 also shows the PDN entry sequence (right). PDN state is entered by sending a PDNR command in a ROW packet. A time tASP is required to enter PDN state (this specification is provided for power calculation purposes). The clock on CTM/CFM must remain stable for a time tCD after the PDNR command. The RDRAM may be in ATTN or STBY state when the PDNR command is issued. When PDN state is exited, the RDRAM will return to the original starting state (ATTN or STBY). If it is in ATTN state and a RLXR command is specified with PDNR, then the RDRAM will return to STBY state when PDN is exited. The current- and slew-rate-control levels are re-established. The RDRAM’s write buffer must be retired with the appropriate COP command before NAP or PDN are entered. Also, all the RDRAM’s banks must be precharged before NAP or PDN are entered. The exception to this is if NAP is entered with the NSR bit of the INIT register cleared (disabling self-refresh in NAP). The commands for relaxing, retiring, and precharging may be given to the RDRAM as late as the ROPa0, COPa0, and XOPa0 packets in Figure 47. No broadcast packets nor packets directed to the RDRAM entering Nap or PDN may overlay the quiet window. This window extends for a time tNPQ after the packet with the NAPR or PDNR command. Figure 48 shows the NAP and PDN exit sequences. These sequences are virtually identical; the minor differences will be highlighted in the following description. Before NAP or PDN exit, the CTM/CFM clock must be stable for a time tCE. Then, on a falling and rising edge of SCK, if there is a “01” on the CMD input, NAP or PDN state will be exited. Also, on the falling SCK edge the SIO0 input must be at a 0 for NAP exit and 1 for PDN exit. Preliminary Information Page 39 Direct RAMBUS 72 Mbit (256kx18x16d) If the PSX bit of the INIT register is 0, then a device PDEV5..0 is specified for NAP or PDN exit on the DQA5..0 pins. This value is driven on the rising SCK edge 0.5 or 1.5 SCK cycles after the original falling edge, depending upon the value of the DQS bit of the NAPX register. If the PSX bit of the INIT register is 1, then the RDRAM ignores the PDEV5..0 address packet and exits NAP or PDN when the wake-up sequence is presented on the CMD wire. The ROW and COL pins must be quiet at a time tS4/tH4 around the indicated falling SCK edge (timed with the PDNX or NAPX register fields). After that, ROW and COL packets may T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 CTM/CFM T16 T17 be directed to the RDRAM which is now in ATTN or STBY state. Figure 49 shows the constraints for entering and exiting NAP and PDN states. On the left side, an RDRAM exits NAP state at the end of cycle T3. This RDRAM may not re-enter NAP or PDN state for an interval of tNU0. The RDRAM enters NAP state at the end of cycle T13. This RDRAM may not re-exit NAP state for an interval of tNU1. The equations for these two parameters depend upon a number of factors, and are shown at the bottom of the figure. NAPX is the value in the NAPX field in the NAPX register. T 18 T 19 T20 T 21 T 22 T23 0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T10 T 11 T12 T 13 T14 T 15 CTM/CFM ROW2 ..ROW0 ROW2 ..ROW0 RLXR COL4 ..COL0 COP a1 COP a1 XOP a1 COP a1 XOP a1 COP a1 COP a0 XOP a1 XOP a1 XOP a0 DQA8..0 DQB8..0 tAS Power State tSA ATTN STBY Power State T20 T21 T22 T23 a0 = {d0,b0,r0} a1 = {d1,b1,c1} ROP a0 TFRM•tCYCLE DQA8..0 DQB8..0 T 19 ROP = non-broadcast ROWA or ROWR/ATTN COL4 ..COL0 RLXC RLXX T16 T17 T18 STBY ATTN No COL packets may be placed in the three indicated positions; i.e. at (TFRM - {1,2,3})•tCYCLE . A COL packet to device d0 (or any other device) is okay at (TFRM)•tCYCLE or later. A COL packet to another device (d1!= d0) is okay at (TFRM - 4)•tCYCLE or earlier. Figure 46: STBY Entry (left) and STBY Exit (right) T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 CTM/CFM T16 T17 T 18 T 19 T20 T 21 T 22 T23 0 T1 T2 T3 T4 ROP a0 (NAPR) restricted quiet ROP a1 ROP a0 (PDNR) COP a0 XOP a0 restricted quiet COL4 ..COL0 COP a1 XOP a1 COP a0 XOP a0 quiet restricted quiet ATTN/STBYa COP a1 XOP a1 Power State ATTN/STBYa T20 T21 T22 T23 ROW or COL packets to a device other than d0 may overlap the restricted interval. tASP NAP T 19 No ROW or COL packets directed to device d0 may overlap the restricted interval. No broadcast ROW packets may overlap the quiet interval. ROP a1 DQA8..0 DQB8..0 tASN a restricted T16 T17 T18 a0 = {d0,b0,r0,c0} a1 = {d1,b1,r1,c1} tNPQ DQA8..0 DQB8..0 Power State T 9 T10 T 11 T12 T 13 T14 T 15 tCD ROW2 ..ROW0 tNPQ COL4 ..COL0 T8 CTM/CFM tCD ROW2 ..ROW0 T5 T6 T7 PDN ROW or COL packets directed to device d0 after the restricted interval will be ignored. The (eventual) NAP/PDN exit will be to the same ATTN/STBY state the RDRAM was in prior to NAP/PDN entry Figure 47: NAP Entry (left) and PDN Entry (right) On the right side of Figure 48, an RDRAM exits PDN state at the end of cycle T3. This RDRAM may not re- Page 40 enter PDN or NAP state for an interval of tPU0. The RDRAM enters PDN state at the end of cycle T13. This Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) of the figure. PDNX is the value in the PDNX field in the PDNX register. RDRAM may not re-exit PDN state for an interval of tPU1. The equations for these two parameters depend upon a number of factors, and are shown at the bottom T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM If PSX=1 in Init register, then NAP/PDN exit is broadcast (no PDEV field). ROW2 ..ROW0 COL4 ..COL0 No ROW packets may overlap the restricted interval b PDEV5..0 tCE PDEV5..0 DQS=0 b,c ROP restricted tS4 tH4 No COL packets may overlap the restricted interval if device PDEV is exiting the NAP-A or PDNA states tS3 tH3 tS3 tH3 DQA8..0 DQB8..0 ROP COP XOP COP XOP restricted tS4 tH4 b DQS=1 b SCK CMD 0 SIO0 0/1a 1 Effective hold becomes tH4’=tH4+[PDNXA•64•tSCYCLE+tPDNXB,MAX]-[PDNX•256•tSCYCLE ] if [PDNX•256•tSCYCLE ] < [PDNXA•64•tSCYCLE +tPDNXB,MAX]. The packet is repeated from SIO0 to SIO1 SIO1 0/1a (NAPX)•tSCYCLE)/(256•PDNX•tSCYCLE) Power State STBY/ATTNd NAP/PDN DQS=0 b DQS=1b c a Use 0 for NAP exit, 1 for PDN exit b Device selection timing slot is selected by DQS field of NAPX register d The DQS field must be written with “1” for this RDRAM. Exit to STBY or ATTN depends upon whether RLXR was asserted at NAP or PDN entry time Figure 48: NAP and PDN Exit T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 CTM/CFM T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 T 10 T 11 T12 T13 T 14 T 15 T16 T17 T 18 T 19 T20 T2 CTM/CFM NAP entry ROW2 ..ROW0 PDN entry ROW2 ..ROW0 NAPR SCK PDNR SCK NAP exit CMD 0 PDN exit 1 tNU0 no entry to NAP or PDN tNU0 = 5•tCYCLE + (2+NAPX)•tSCYCLE tNU1 = 8•t CYCLE - (0.5•tSCYCLE ) if NSR=0 = 23•t CYCLE if NSR=1 0 1 CMD tNU1 no exit 0 1 0 1 tPU0 tPU1 no exit no entry to NAP or PDN tPU0 = 5•t CYCLE + (2+256•PDNX)•tSCYCLE tPU1 = 8•t CYCLE - (0.5•t SCYCLE) if PSR=0 = 23•t CYCLE if PSR=1 Figure 49: NAP Entry/Exit Windows (left) and PDN Entry/Exit Windows (right) INFINEON Technologies Version 1.0 Preliminary Information Page 41 Direct RAMBUS 72 Mbit (256kx18x16d) Refresh precharge the refreshed bank in all RDRAMs. After a bank is given a REFA command, no other core operations (activate or precharge) should be issued to it until it receives a REFP. RDRAMs, like any other DRAM technology, use volatile storage cells which must be periodically refreshed. This is accomplished with the REFA command. Figure 50 shows an example of this. It is also possible to interleave refresh transactions (not shown). In the figure, the ACT b0 command would be replaced by a REFA b0 command. The b0 address would be broadcast to all devices, and would be {Broadcast,Ba+2,REFR}. Note that the bank address should skip by two to avoid adjacent bank interference. A possible bank incrementing pattern would be: {13, 11, 9, 7, 5, 3, 1, 8, 10, 12, 14, 0, 2, 4, 6, 15}. Every time bank 15 is reached, the REFA command would automatically increment the REFR register. The REFA command in the transaction is typically a broadcast command (DR4T and DR4F are both set in the ROWR packet), so that in all devices bank number Ba is activated with row number REFR, where REFR is a control register in the RDRAM. When the command is broadcast and ATTN is set, the power state of the RDRAMs (ATTN or STBY) will remain unchanged. The controller increments the bank address Ba for the next REFA command. When Ba is equal to its maximum value, the RDRAM automatically increments REFR for the next REFA command. A second refresh mechanism is available for use in PDN and NAP power states. This mechanism is called self-refresh mode. When the PDN power state is entered, or when NAP power state is entered with the NSR control register bit set, then self-refresh is automatically started for the RDRAM. On average, these REFA commands are sent once every tREF/2BBIT+RBIT (where BBIT are the number of bank address bits and RBIT are the number of row address bits) so that each row of each bank is refreshed once every tREF interval. Self-refresh uses an internal time base reference in the RDRAM. This causes an activate and precharge to be carried out once in every tREF/2BBIT+RBIT interval. The REFB and REFR control registers are used to keep track of the bank and row being refreshed. The REFA command is equivalent to an ACT command, in terms of the way that it interacts with other packets (see Table 10). In the example, an ACT command is sent after tRR to address b0, a different (non-adjacent) bank than the REFA command. Before a controller places an RDRAM into self-refresh mode, it should perform REFA/REFP refreshes until the bank address is equal to the maximum value. This ensures that no rows are skipped. Likewise, when a controller returns an RDRAM to REFA/REFP refresh, it should start with the minimum bank address value (zero). A second ACT command can be sent after a time tRC to address c0, the same bank (or an adjacent bank) as the REFA command. Note that a broadcast REFP command is issued a time tRAS after the initial REFA command in order to T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM tRC ROW2 ..ROW0 REFA a0 ACT b0 REFP a1 tRAS COL4 ..COL0 ACT c0 REFA d0 tRP tRR tREF/2BBIT+RBIT DQA8..0 DQB8..0 Transaction a: REFA a0 = {Broadcast,Ba,REFR} Transaction b: xx b0 = {Db, /={Ba,Ba+1,Ba-1}, Rb} Transaction c: xx c0 = {Dc, ==Ba, Rc} Transaction d: REFA d0 = {Broadcast,Ba+1,REFR} a1 = {Broadcast,Ba} BBIT = # bank address bits RBIT = # row address bits REFB = REFB3..REFB0 REFR = REFR8..REFR0 Figure 50: REFA/REFP Refresh Transaction Example Page 42 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Current and Temperature Control Figure 51 shows an example of a transaction which performs current control calibration. It is necessary to perform this operation once to every RDRAM in every tCCTRL interval in order to keep the IOL output current in its proper range. This example uses four COLX packets with a CAL command. These cause the RDRAM to drive four calibration packets Q(a0) a time tCAC later. An offset of tRDTOCC must be placed between the Q(a0) packet and read data Q(a1)from the same device. These calibration packets are driven on the DQA4..3 and DQB4..3 wires. The TSQ bit of the INIT register is driven on the DQA5 wire during same interval as the calibration packets. The remaining DQA and DQB wires are not used during these calibration packets. The last COLX packet also contains a SAM command (concatenated with the T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 CAL command). The RDRAM samples the last calibration packet and adjusts its IOL current value. Unlike REF commands, CAL and SAM commands cannot be broadcast. This is because the calibration packets from different devices would interfere. Therefore, a current control transaction must be sent every tCCTRL/N, where N is the number of RDRAMs on the Channel. The device field Da of the address a0 in the CAL/SAM command should be incremented after each transaction. Figure 23 shows an example of a temperature calibration sequence to the RDRAM. This sequence is broadcast once every tTEMP interval to all the RDRAMs on the Channel. The TCEN and TCAL are ROP commands, and cause the slew rate of the output drivers to adjust for temperature drift. During the quiet interval tTCQUIET the devices being calibrated can’t be read, but they can be written. T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM Read data from the same device from an earlier RD command must be at this packet position or earlier. ROW2 ..ROW0 Read data from a different device from an earlier RD command can be anywhere prior to the Q(a0) packet. . tCCTRL COL4 ..COL0 CAL a0 CAL a0 CAL a0 Read data from a different device from a later RD command can be anywhere after to the Q(a0) packet. CAL/SAM a0 CAL a2 tCAC DQA8..0 DQB8..0 Read data from the same device from a later RD command must be at this packet position or later. CAL tCCSAMTOREAD Q (a1) Q (a0) Q (a1) DQA5 of the first calibrate packet has the inverted TSQ bit of INIT control register; i.e. logic 0 or high voltage means hot temperature. When used for monitoring, it should be enabled with the DQA3 bit (current control one value) in case there is no RDRAM present: HotTemp = DQA5•DQA3 Note that DQB3 could be used instead of DQA3. tREADTOCC Transaction a0: CAL/SAM Transaction a1: RD Transaction a2: CAL/SAM a0 = {Da, Bx} a1 = {Da, Bx} a2 = {Da, Bx} Figure 51: Current Control CAL/SAM Transaction Example T0 T1 T2 T3 T4 T5 T6 T7 T8 T 9 T 10 T 11 T12 T 13 T 14 T 15 T16 T17 T 18 T 19 T20 T 21 T 22 T 23 T24 T25 T 26 T 27 T28 T 29 T 30 T 31 T32 T33 T 34 T 35 T36 T37 T 38 T 39 T40 T41 T 42 T 43 T44 T 45 T 46 T 47 CTM/CFM tTEMP ROW2 ..ROW0 TCEN TCAL tTCEN COL4 ..COL0 TCEN tTCAL tTCQUIET Any ROW packet may be placed in the gap between the ROW packets with the TCEN and TCAL commands. DQA8..0 DQB8..0 No read data from devices being calibrated Figure 52: Temperature Calibration (TCEN-TCAL) Transactions to RDRAM INFINEON Technologies Version 1.0 Preliminary Information Page 43 Direct RAMBUS 72 Mbit (256kx18x16d) Electrical Conditions Table 17: Electrical Conditions Symbol Parameter and Conditions Min Max Unit TJ Junction temperature under bias TBD TBD °C VDD, VDDA Supply voltage 2.50 - 0.13 2.50 + 0.13 V VDD,N, VDDA,N Supply voltage droop (DC) during NAP interval (tNLIMIT) - 2.0 % vDD,N, vDDA,N Supply voltage ripple (AC) during NAP interval (tNLIMIT) -2.0 2.0 % VCMOS Supply voltage for CMOS pins (2.5V controllers) Supply voltage for CMOS pins (1.8V controllers) 2.50 - 0.13 1.80 - 0.1 2.50 + 0.25 1.80 + 0.2 V V VTERM Termination voltage 1.80 - 0.1 1.80 + 0.1 V VREF Reference voltage 1.40 - 0.2 1.40 + 0.2 V VDIL RSL data input - low voltage VREF - 0.5 VREF - 0.2 V VDIH RSL data input - high voltage VREF + 0.2 VREF + 0.5 V VDIS RSL data input swing: VDIS = VDIH - VDIL 0.4 1.0 V ADI RSL data asymmetry: ADI = [(V DIH - VREF) + (VDIL - VREF)]/VDIS 0 -20 % VX RSL clock input - crossing point of true and complement signals 1.3 1.8 V VCM RSL clock input - common mode VCM = (VCIH+VCIL)/2 1.4 1.7 V VCIS,CTM RSL clock input swing: V CIS = VCIH - VCIL (CTM,CTMN pins). 0.35 0.70 V VCIS,CFM RSL clock input swing: V CIS = VCIH - VCIL (CFM,CFMN pins). 0.125 0.70 V VIL,CMOS CMOS input low voltage - 0.3 VCMOS/2 - 0.25 V VIH,CMOS CMOS input high voltage VCMOS/2 + 0.25 V CMOS+0.3 V Timing Conditions Table 18: Timing Conditions Symbol Parameter Min Max Unit Figure(s) tCYCLE CTM and CFM cycle times (-600) CTM and CFM cycle times (-711) CTM and CFM cycle times (-800) 3.33 2.80 2.50 3.83 3.83 3.83 ns ns ns Figure 53 Figure 53 Figure 53 tCR, tCF CTM and CFM input rise and fall times 0.2 0.5 ns Figure 53 tCH, tCL CTM and CFM high and low times 40% 60% tCYCLE Figure 53 tTR CTM-CFM differential (MSE/MS=0/0) CTM-CFM differential (MSE/MS=1/1)a 0.0 0.9 1.0 1.0 tCYCLE Figure 42 Figure 53 tDCW Domain crossing window -0.1 0.1 tCYCLE Figure 59 tDR, tDF DQA/DQB/ROW/COL input rise/fall times 0.2 0.65 ns Figure 54 Page 44 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Table 18: Timing Conditions Symbol Parameter Min Max Unit Figure(s) tS , tH DQA/DQB/ROW/COL-to-CFM set/hold @ tCYCLE=3.33ns DQA/DQB/ROW/COL-to-CFM set/hold @ tCYCLE=2.81ns DQA/DQB/ROW/COL-to-CFM set/hold @ tCYCLE=2.50ns 0.275b,d 0.240c,d 0.200d - ns ns ns Figure 54 Figure 54 Figure 54 tDR1, tDF1 SIO0, SIO1 input rise and fall times - 5.0 ns Figure 56 tDR2, tDF2 CMD, SCK input rise and fall times - 2.0 ns Figure 56 tCYCLE1 SCK cycle time - Serial control register transactions 1000 - ns Figure 56 10 - ns Figure 56 4.25 - ns Figure 56 1 - ns Figure 56 SCK cycle time - Power transitions tCH1, tCL1 SCK high and low times falling edgee tS1 CMD setup time to SCK rising or tH1 CMD hold time to SCK rising or falling edgec 1 - ns Figure 56 tS2 SIO0 setup time to SCK falling edge 40 - ns Figure 56 tH2 SIO0 hold time to SCK falling edge 40 - ns Figure 56 tS3 PDEV setup time on DQA5..0 to SCK rising edge. 0 - ns tH3 PDEV hold time on DQA5..0 to SCK rising edge. 5.5 - ns Figure 48, Figure 57 tS4 ROW2..0, COL4..0 setup time for quiet window -1 - tCYCLE Figure 48 tH4 ROW2..0, COL4..0 hold time for quiet windowf 5 - tCYCLE Figure 48 vIL,CMOS CMOS input low voltage - over/undershoot voltage duration is less than or equal to 5ns - 0.7 VCMOS/2 - 0.6 V vIH,CMOS CMOS input high voltage - over/undershoot voltage duration is less than or equal to 5ns VCMOS/2 + 0.6 VCMOS + 0.7 V tNPQ Quiet on ROW/COL bits during NAP/PDN entry 4 - tCYCLE Figure 47 tREADTOCC Offset between read data and CC packets (same device) 12 - tCYCLE Figure 51 tCCSAMTOREAD Offset between CC packet and read data (same device) 8 - tCYCLE Figure 51 tCE CTM/CFM stable before NAP/PDN exit 2 - tCYCLE Figure 48 tCD CTM/CFM stable after NAP/PDN entry 100 - tCYCLE Figure 47 tFRM ROW packet to COL packet ATTN framing delay 7 - tCYCLE Figure 46 tNLIMIT Maximum time in NAP mode 10.0 µs Figure 45 tREF Refresh interval 32 ms Figure 50 tCCTRL Current control interval 100ms ms/tCYCLE Figure 51 tTEMP Temperature control interval 100 ms Figure 23 tTCEN TCE command to TCAL command 150 - tCYCLE Figure 23 tTCAL TCAL command to quiet window 2 2 tCYCLE Figure 23 tTCQUIET Quiet window (no read data) 140 - tCYCLE Figure 23 tPAUSE RDRAM delay (no RSL operations allowed) 200.0 µs page 28 34 tCYCLE a. MSE/MS are fields of the SKIP register. For this combination (skip override) the tDCW parameter range is effectively 0.0 to 0.0. INFINEON Technologies Version 1.0 Preliminary Information Page 45 Direct RAMBUS 72 Mbit (256kx18x16d) b. This parameter also applies to a -800 or -711 part when operated with tCYCLE=3.33ns. c. This parameter also applies to a -800 part when operated with tCYCLE=2.81ns. d. tS,MIN and tH,MIN for other tCYCLE values can be interpolated between or extrapolated from the timings at the 3 specified tCYCLE values. e. With VIL,CMOS=0.5VCMOS-0.6V and VIH,CMOS=0.5VCMOS+0.6V f. Effective hold becomes tH4 ’=tH4+[PDNXA•64•tSCYCLE+tPDNXB,MAX]-[PDNX•256•tSCYCLE] if [PDNX•256•tSCYCLE] < [PDNXA•64•tSCYCLE+tPDNXB,MAX]. See Figure 48. Page 46 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Electrical Characteristics Table 19: Electrical Characteristics Symbol Parameter and Conditions Min ΘJC Junction-to-Case thermal resistance IREF VREF current @ VREF,MAX IOH RSL output high current @ (0≤VOUT≤VDD) Max Unit TBD °C/Watt -10 10 µA -10 10 µA 30.0 90.0 mA - 2.0 mA 150 - Ω -10.0 10.0 µA - 0.3 V VCMOS-0.3 - V a IALL RSL IOL current @ VOL = 0.9V, VDD,MIN , TJ,MAX ∆IOL RSL IOL current resolution step rOUT Dynamic output impedance II,CMOS CMOS input leakage current @ (0≤VI,CMOS≤VCMOS) VOL,CMOS CMOS output voltage @ IOL,CMOS= 1.0mA VOH,CMOS CMOS output high voltage @ I OH,CMOS = -0.25mA a. This measurement is made in manual current control mode; i.e. with all output device legs sinking current. Timing Characteristics Table 20: Timing Characteristics Symbol Parameter Min Max Unit Figure(s) tQ CTM-to-DQA/DQB output time @ tCYCLE =3.33ns CTM-to-DQA/DQB output time @ tCYCLE =2.81ns CTM-to-DQA/DQB output time @ tCYCLE =2.50ns -0.350a,c -0.300b,c -0.260c +0.350a,c +0.300b,c +0.260c ns ns ns Figure 55 Figure 55 Figure 55 tQR, tQF DQA/DQB output rise and fall times 0.2 0.45 ns Figure 55 tQ1 SCK(neg)-to-SIO0 delay @ CLOAD,MAX = 20pF (SD read data valid). - 10 ns Figure 58 tHR SCK(pos)-to-SIO0 delay @ CLOAD,MAX = 20pF (SD read data hold). 2 - ns Figure 58 tQR1, tQF1 SIOOUT rise/fall @ CLOAD,MAX = 20pF - 5 ns Figure 58 tPROP1 SIO0-to-SIO1 or SIO1-to-SIO0 delay @ CLOAD,MAX = 20pF - 10 ns Figure 58 tNAPXA NAP exit delay - phase A - 50 ns Figure 48 tNAPXB NAP exit delay - phase B - 40 ns Figure 48 tPDNXA PDN exit delay - phase A - 4 µs Figure 48 tPDNXB PDN exit delay - phase B - 9000 tCYCLE Figure 48 tAS ATTN-to-STBY power state delay - 1 tCYCLE Figure 46 tSA STBY-to-ATTN power state delay - 0 tCYCLE Figure 46 tASN ATTN/STBY-to-NAP power state delay - 8 tCYCLE Figure 47 tASP ATTN/STBY-to-PDN power state delay - 8 tCYCLE Figure 47 a. This parameter also applies to a -800 or -711 part when operated with tCYCLE=3.33ns. b. This parameter also applies to a -800 part when operated with tCYCLE =2.81ns. c. tQ,MIN and tQ,MAX for other tCYCLE values can be interpolated between or extrapolated from the timings at the 3 specified tCYCLE values. INFINEON Technologies Version 1.0 Preliminary Information Page 47 Direct RAMBUS 72 Mbit (256kx18x16d) RSL - Clocking outputs. Most timing is measured relative to the points where they cross. The tCYCLE parameter is measured from the falling CTM edge to the falling CTM edge. The tCL and tCH parameters are measured from falling to rising and rising to falling edges of CTM. The tCR and tCF rise- and fall-time parameters are measured at the 20% and 80% points. Figure 53 is a timing diagram which shows the detailed requirements for the RSL clock signals on the Channel. The CTM and CTMN are differential clock inputs used for transmitting information on the DQA and DQB, tCYCLE tCL tCH tCR tCR CTM VCIH 80% VXVCM 50% VX+ 20% VCIL CTMN tCF tTR tCF tCR tCR CFM VCIH 80% VXVCM 50% VX+ 20% VCIL CFMN tCF tCL tCYCLE tCF tCH Figure 53: RSL Timing - Clock Signals The CFM and CFMN are differential clock outputs used for receiving information on the DQA, DQB, ROW and COL outputs. Most timing is measured relative to the points where they cross. The tCYCLE parameter is measured from the falling CFM edge to the falling CFM edge. The tCL and tCH parameters are measured from falling to rising and rising to falling Page 48 edges of CFM. The tCR and tCF rise- and fall-time parameters are measured at the 20% and 80% points. The tTR parameter specifies the phase difference that may be tolerated with respect to the CTM and CFM differential clock inputs (the CTM pair is always earlier). Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) RSL - Receive Timing Figure 54 is a timing diagram which shows the detailed requirements for the RSL input signals on the Channel. The DQA, DQB, ROW, and COL signals are inputs which receive information transmitted by a Direct RAC on the Channel. Each signal is sampled twice per tCYCLE interval. The set/hold window of the sample points is tS/tH. The sample points are centered at the 0% and 50% points of a cycle, measured relative to the crossing points of the falling CFM clock edge. The set and hold parameters are measured at the VREF voltage point of the input transition. The tDR and tDF rise- and fall-time parameters are measured at the 20% and 80% points of the input transition. CFM VCIH 80% VXVCM 50% VX+ 20% VCIL CFMN DQA 0.5•tCYCLE tDR tS DQB tH tS tH VDIH ROW 80% COL even odd VREF 20% VDIL tDF Figure 54: RSL Timing - Data Signals for Receive INFINEON Technologies Version 1.0 Preliminary Information Page 49 Direct RAMBUS 72 Mbit (256kx18x16d) RSL - Transmit Timing Figure 55 is a timing diagram which shows the detailed requirements for the RSL output signals on the Channel. The DQA and DQB signals are outputs to transmit information that is received by a Direct RAC on the Channel. Each signal is driven twice per tCYCLE interval. The beginning and end of the even transmit window is at the 75% point of the previous cycle and at the 25% point of the current cycle. The beginning and end of the odd transmit window is at the 25% point and at the 75% point of the current cycle. These transmit points are measured relative to the crossing points of the falling CTM clock edge. The size of the actual transmit window is less than the ideal tCYCLE/2, as indicated by the non-zero values of tQ,MIN and tQ,MAX. The tQ parameters are measured at the 50% voltage point of the output transition. The tQR and tQF rise- and fall-time parameters are measured at the 20% and 80% points of the output transition. CTM VCIH 80% VXVCM 50% VX+ 20% CTMN VCIL 0.75•tCYCLE 0.75•tCYCLE 0.25•tCYCLE DQA tQ,MAX tQR tQ,MAX tQ,MIN DQB tQ,MIN VQH 80% even odd 50% 20% VQL tQF Figure 55: RSL Timing - Data Signals for Transmit Page 50 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) CMOS - Receive Timing and SIO0 are tDR1 and tDF1, measured at the 20% and 80% levels. Figure 56 is a timing diagram which shows the detailed requirements for the CMOS input signals . The CMD and SIO0 signals are inputs which receive information transmitted by a controller (or by another RDRAM’s SIO1 output. SCK is the CMOS clock signal driven by the controller. All signals are high true. The cycle time, high phase time, and low phase time of the SCK clock are tCYCLE1, tCH1 and tCL1, all measured at the 50% level. The rise and fall times of SCK, CMD, The CMD signal is sampled twice per tCYCLE1 interval, on the rising edge (odd data) and the falling edge (even data). The set/hold window of the sample points is tS1/tH1. The SCK and CMD timing points are measured at the 50% level. The SIO0 signal is sampled once per tCYCLE1 interval on the falling edge. The set/hold window of the sample points is tS2/tH2. The SCK and SIO0 timing points are measured at the 50% level. tDR2 VIH,CMOS SCK 80% 50% 20% tCYCLE1 tCH1 tDF2 tDR2 VIL,CMOS tCL1 tS1 tH1 tS1 tH1 VIH,CMOS CMD 80% even odd 50% 20% VIL,CMOS tDF2 tDR1 tS2 tH2 VIH,CMOS SIO0 80% 50% 20% VIL,CMOS tDF1 Figure 56: CMOS Timing - Data Signals for Receive INFINEON Technologies Version 1.0 Preliminary Information Page 51 Direct RAMBUS 72 Mbit (256kx18x16d) The SCK clock is also used for sampling data on RSL inputs in one situation. Figure 48 shows the PDN and NAP exit sequences. If the PSX field of the INIT register is one (see Figure 27), then the PDN and NAP exit sequences are broadcast; i.e. all RDRAMs that are in PDN or NAP will perform the exit sequence. If the PSX field of the INIT register is zero, then the PDN and NAP exit sequences are directed; i.e. only one RDRAM that is in PDN or NAP will perform the exit sequence. The address of that RDRAM is specified on the DQA[5:0] bus in the set hold window tS3/tH3 around the rising edge of SCK. This is shown in Figure 57. The SCK timing point is measured at the 50% level, and the DQA[5:0] bus signals are measured at the VREF level. VIH,CMOS SCK 80% 50% 20% VIL,CMOS tS3 tH3 VDIH DQA[5:0] 80% PDEV VREF 20% VDIL Figure 57: CMOS Timing - Device Address for NAP or PDN Exit Page 52 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) CMOS - Transmit Timing Figure 58 is a timing diagram which shows the detailed requirements for the CMOS output signals. The SIO0 signal is driven once per tCYCLE1 interval on the falling edge. The clock-to-output window is tQ1,MIN/tQ1,MAX. The SCK and SIO0 timing points are measured at the 50% level. The rise and fall times of SIO0 are tQR1 and tQF1, measured at the 20% and 80% levels. VIH,CMOS SCK 80% 50% 20% tQ1,MAX VIL,CMOS tHR,MIN tQR1 VOH,CMOS SIO0 80% 50% 20% VOL,CMOS tQF1 tDR1 VIH,CMOS SIO0 or SIO1 80% 50% 20% tPROP1,MAX tDF1 tPROP1,MIN VIL,CMOS tQR1 VOH,CMOS SIO1 or SIO0 80% 50% 20% VOL,CMOS tQF1 Figure 58: CMOS Timing - Data Signals for Transmit INFINEON Technologies Version 1.0 Preliminary Information Page 53 Direct RAMBUS 72 Mbit (256kx18x16d) Figure 58 also shows the combinational path connecting SIO0 to SIO1 and the path connecting SIO1 to SIO0 (read data only). The tPROP1 parameter specified this propagation delay. The rise and fall times of SIO0 and SIO1 inputs must be tDR1 and tDF1, measured at the 20% and 80% levels. The rise and fall times of SIO0 and SIO1 outputs are tQR1 and tQF1, measured at the 20% and 80% levels. RSL - Domain Crossing Window When read data is returned by the RDRAM, imformation must cross from the receive clock domain (CFM) to the transmit clock domain (CTM). The tTR parameter permits the CFM to CTM phase to vary through an entire cycle; i.e. there is no restriction on the alignment of these two clocks. A second parameter tDCW is needed in order to describe how the delay between a CFM ••• tTR DQA/B Case A tTR=0 tCAC-tTR Case A’ tTR=0 tCAC -tTR-tCYCLE tTR DQA/B Case B tTR=tDCW,MAX tCAC-tTR Case B’ tTR=tDCW,MAX tCAC-tTR-tCYCLE tTR Case C tTR=0.5•tCYCLE tTR Q(a1) tCAC-tTR Case D tTR=tCYCLE+tDCW,MIN Q(a1) tCAC-tTR Case D’ tTR=tCYCLE+tDCW,MIN DQA/B Q(a1) tCAC-tTR+tCYCLE Q(a1) ••• CTM DQA/B Q(a1) ••• CTM DQA/B Q(a1) ••• CTM DQA/B Q(a1) ••• CTM DQA/B tCYCLE RD a1 CTM DQA/B Figure 59 shows this timing for five distinct values of tTR. Case A (tTR=0) is what has been used throughout this document. The delay between the RD command and read data is tCAC. As tTR varies from zero to tCYCLE (cases A through E), the command to data delay is (tCAC-tTR). When the tTR value is in the range 0 to tDCW,MAX, the command to data delay can also be (tCAC-tTR-tCYCLE). This is shown as cases A’ and B’ (the gray packets). Similarly, when the tTR value is in the range (tCYCLE+tDCW,MIN) to tCYCLE, the command to data delay can also be (tCAC-tTR+tCYCLE). This is shown as cases D’ and E’ (the gray packets). The RDRAM will work reliably with either the white or gray packet timing. The delay value is selected at initialization, and remains fixed thereafter. ••• COL DQA/B RD command packet and read data packet varies as a function of the tTR value. tTR Case E tTR=tCYCLE tCAC-tTR Case E’ tTR=tCYCLE tCAC-tTR+tCYCLE Q(a1) Q(a1) Figure 59: RSL Transmit - Crossing Read Domains Page 54 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Timing Parameters Table 21: Timing Parameter Summary Min Min Min Min Min Min Min -40 -45 -50 -45 -50 -45 -53 Max Units -800 -800 -800 -711 -711 -600 -600 Parameter Description tRC Row Cycle time of RDRAM banks -the interval between ROWA packets with ACT commands to the same bank. 28 28 34 28 28 22 28 - tCYCLE Figure 15 Figure 16 tRAS RAS-asserted time of RDRAM bank - the interval between 20 ROWA packet with ACT command and next ROWR packet with PRERa command to the same bank. 20 24 20 20 16 20 64µs tCYCLE Figure 15 Figure 16 tRP Row Precharge time of RDRAM banks - the interval between ROWR packet with PRERa command and next ROWA packet with ACT command to the same bank. 8 8 10 8 8 6 8 - tCYCLE Figure 15 Figure 16 tPP Precharge-to-precharge time of RDRAM device - the inter- 8 val between successive ROWR packets with PRER a commands to any banks of the same device. 8 8 8 8 8 8 - tCYCLE Figure 12 tRR RAS-to-RAS time of RDRAM device - the interval between successive ROWA packets with ACT commands to any banks of the same device. 8 8 8 8 8 8 8 - tCYCLE Figure 13 tRCD RAS-to-CAS Delay - the interval from ROWA packet with ACT command to COLC packet with RD or WR command). Note - the RAS-to-CAS delay seen by the RDRAM core (tRCD-C) is equal to tRCD-C = 1 + tRCD because of differences in the row and column paths through the RDRAM interface. 7 9 11 7 9 5 7 - tCYCLE Figure 15 Figure 16 tCAC CAS Access delay - the interval from RD command to Q read data. The equation for tCAC is given in the TPARM register in Figure 39. 8 8 8 8 8 7 8 12 tCYCLE Figure 4 Figure 39 tCWD CAS Write Delay (interval from WR command to D write data. 6 6 6 6 6 6 6 6 tCYCLE Figure 4 tCC CAS-to-CAS time of RDRAM bank - the interval between successive COLC commands). 4 4 4 4 4 4 4 - tCYCLE Figure 15 Figure 16 tPACKET Length of ROWA, ROWR, COLC, COLM or COLX packet. 4 4 4 4 4 4 4 4 tCYCLE Figure 3 tRTR Interval from COLC packet with WR command to COLC packet which causes retire, and to COLM packet with bytemask. 8 8 8 8 8 8 8 - tCYCLE Figure 17 tOFFP The interval (offset) from COLC packet with RDA command, or from COLC packet with retire command (after WRA automatic precharge), or from COLC packet with PREC command, or from COLX packet with PREX command to the equivalent ROWR packet with PRER. The equation for tOFFP is given in the TPARM register in Figure 39. 4 4 4 4 4 4 4 4 tCYCLE Figure 14 Figure 39 tRDP Interval from last COLC packet with RD command to ROWR packet with PRER. 4 4 4 4 4 4 4 - tCYCLE Figure 15 tRTP Interval from last COLC packet with automatic retire com- 4 mand to ROWR packet with PRER. 4 4 4 4 4 4 - tCYCLE Figure 16 b Figure(s) a. Or equivalent PREC or PREX command. See Figure 14. b. This is a constraint imposed by the core, and is therefore in units of µs rather than tCYCLE. INFINEON Technologies Version 1.0 Preliminary Information Page 55 Direct RAMBUS 72 Mbit (256kx18x16d) Absolute Maximum Ratings Table 22: Absolute Maximum Ratings Symbol Parameter Min Max Unit VI,ABS Voltage applied to any RSL or CMOS pin with respect to Gnd - 0.3 VDD+0.3 V VDD,ABS, V DDA,ABS Voltage on VDD and VDDA with respect to Gnd - 0.5 VDD+1.0 V TSTORE Storage temperature - 50 100 °C IDD - Supply Current Profile Table 23: Supply Current Profile IDD value RDRAM blocks consuming power @ tCYCLE=2.5nsa Min Max Unit IDD,PDN Self-refresh only for INIT.LSR=0 TBD 1500 µA IDD,PDN,L Self-refresh only for INIT.LSR= 1 TBD 700 µA IDD,NAP T/RCLK-Nap TBD 4.2 mA IDD,STBY T/RCLK, ROW-demux TBD 101 mA IDD,ATTN T/RCLK, ROW-demux, COL-demux TBD 148 mA b mA mA IDD,ATTN-W T/RCLK, ROW-demux,COL-demux,DQ-demux,1•WR-SenseAmp,4•ACT-Bank TBD 575/635 IDD,ATTN-R T/RCLK, ROW-demux,COL-demux,DQ-mux,1•RD-SenseAmp,4•ACT-Bank c TBD 567/575b a. The CMOS interface consumes power in all power states. b. x16/x18 RDRAM data width. c. This does not include the IOL sink current. The RDRAM dissipates IOL•VOL in each output driver when a logic one is driven. IDD value RDRAM blocks consuming power @ tCYCLE=3.3nsa Min Max Unit IDD,PDN Self-refresh only for INIT.LSR=0 TBD 1500 µA IDD,PDN,L Self-refresh only for INIT.LSR= 1 TBD 700 µA IDD,NAP Refresh, T/RCLK-Nap TBD TBD mA IDD,STBY Refresh, T/RCLK, ROW-demux TBD TBD mA IDD,ATTN Refresh, T/RCLK, ROW-demux, COL-demux TBD TBD mA IDD,ATTN-W Refresh,T/RCLK, ROW-demux,COL-demux,DQ-demux,1•WR-SenseAmp,4•ACT-Bank TBD TBD mA IDD,ATTN-R Refresh,T/RCLK, ROW-demux,COL-demux,DQ-mux,1•RD-SenseAmp,4•ACT-Bank b TBD TBD mA a. The CMOS interface consumes power in all power states. b. This does not include the IOL sink current. The RDRAM dissipates IOL•V OL in each output driver when a logic one is driven. Page 56 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Capacitance and Inductance Figure 60 shows the equivalent load circuit of the RSL and CMOS pins. The circuit models the load that the device presents to the Channel. LI Pad DQA,DQB,RQ Pin CI RI Gnd Pin LI Pad CTM,CTMN, CFM,CFMN Pin CI RI Gnd Pin LI,CMOS Pad SCK,CMD Pin CI,CMOS Gnd Pin LI,CMOS Pad SIO0,SIO1 Pin CI,CMOS,SIO Gnd Pin Figure 60: Equivalent Load Circuit for RSL Pins INFINEON Technologies Version 1.0 Preliminary Information Page 57 Direct RAMBUS 72 Mbit (256kx18x16d) This circuit does not include pin coupling effects that are often present in the packaged device. Because coupling effects make the effective single-pin inductance LI, and capacitance CI, a function of neighboring pins, these parameters are intrinsically data-dependent. For purposes of specifying the device electrical loading on the Channel, the effective L I and CI are defined as the worst-case values over all specified operating conditions. ment places each RSL signal adjacent to an AC ground (a Gnd or Vdd pin), the effective inductance must be defined based on this configuration. Therefore, LI assumes a loop with the RSL pin adjacent to an AC ground. CI is defined as the effective pin capacitance based on the device pin assignment. It is the sum of the effective package pin capacitance and the IO pad capacitance. LI is defined as the effective pin inductance based on the device pin assignment. Because the pad assignTable 24: RSL Pin Parasitics Symbol Parameter and Conditions - RSL pins Min Max Unit LI RSL effective input inductance 4.0 nH L12 Mutual inductance between any DQA or DQB RSL signals. 0.2 nH Mutual inductance between any ROW or COL RSL signals. 0.6 nH ∆LI Difference in LI value between any RSL pins of a single device. - 1.8 nH CI RSL effective input capacitancea RSL effective input capacitancea RSL effective input capacitancea 2.0 2.0 2.0 2.4 2.4 2.6 pF pF pF C12 Mutual capacitance between any RSL signals. - 0.1 pF ∆CI Difference in CI value between average of CTM/CFM and any RSL pins of a single device. - 0.06 pF RI RSL effective input resistance 4 15 Ω -800 -711 -600 a. This value is a combination of the device IO circuitry and package capacitances. Table 25: CMOS Pin Parasitics Symbol LI ,CMOS Parameter and Conditions - CMOS pins Min CMOS effective input inductance a Max Unit 8.0 nH CI ,CMOS CMOS effective input capacitance (SCK,CMD) 1.7 2.1 pF CI ,CMOS,SIO CMOS effective input capacitance (SIO1, SIO0)a - 7.0 pF a. This value is a combination of the device IO circuitry and package capacitances. Page 58 Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) Center-Bonded uBGA Package Figure 61 shows the form and dimensions of the recommended package for the center-bonded CSP device class. D A B C D E F G H Top J Bottom 1 2 3 4 A 5 6 7 e2 8 e1 d Bottom E1 E Bottom Table 26 lists the numerical values corresponding to dimensions shown in Figure 61. Figure 61: Center-Bonded uBGA Package Table 26: Center-Bonded uBGA Package Dimensions Symbol Parameter Min Max Unit e1 Ball pitch (x-axis) 1.00 1.00 mm e2 Ball pitch (y-axis) 0.8 0.8 mm A Package body length notea notea - D Package body width notea notea - E Package total thickness 0.65 1.20 mm E1 Ball height 0.20 0.43 mm d Ball diameter 0.33 0.50 mm a. Package length and width vary with die size for chip scale packages. INFINEON Technologies Version 1.0 Preliminary Information Page 59 Direct RAMBUS 72 Mbit (256kx18x16d) Glossary of Terms controller A logic-device which drives the ROW/COL /DQ wires for a Channel of RDRAMs. ACT Activate command from AV field. COP Column opcode field in COLC packet. activate To access a row and place in sense amp. core The banks and sense amps of an RDRAM. adjacent Two RDRAM banks which share sense amps (also called doubled banks). CTM,CTMN Clock pins for transmitting packets. ASYM CCA register field for RSL VOL/VOH. ATTN Power state - ready for ROW/COL packets. D Write data packet on DQ pins. ATTNR Power state - transmitting Q packets. DBL CNFGB register field - doubled-bank. ATTNW Power state - receiving D packets. DC Device address field in COLC packet. AV Opcode field in ROW packets. device An RDRAM on a Channel. DEVID Control register with device address that is matched against DR, DC, and DX fields. Device match for ROW packet decode. RBIT CBIT IOL value of RSL output drivers. bank A block of 2 •2 core of the RDRAM. BC Bank address field in COLC packet. DM BBIT CNFGA register field - # bank address bits. doubled-bank RDRAM with shared sense amp. broadcast An operation executed by all RDRAMs. DQ DQA and DQB pins. BR Bank address field in ROW packets. DQA Pins for data byte A. bubble Idle cycle(s) on RDRAM pins needed because of a resource constraint. DQB Pins for data byte B. BYT CNFGB register field - 8/9 bits per byte. DQS NAPX register field - PDN/NAP exit. BX Bank address field in COLX packet. C Column address field in COLC packet. dualoct 16 bytes - the smallest addressable datum. CAL DX Device address field in COLX packet. CBIT Calibrate (IOL) command in XOP field. CNFGB register field - # column address bits. field A collection of bits in a packet. CCA Control register - current control A. INIT Control register with initialization fields. CCB Control register - current control B. initialization Configuring a Channel of RDRAMs so they are ready to respond to transactions. CFM,CFMN Clock pins for receiving packets. LSR Channel ROW/COL/DQ pins and external wires. CNFGA register field - low-power selfrefresh. CLRR Clear reset command from SOP field. M Mask opcode field (COLM/COLX packet). CMD CMOS pin for initialization/power control. MA Field in COLM packet for masking byte A. CNFGA Control register with configuration fields. MB Field in COLM packet for masking byte B. CNFGB Control register with configuration fields. MSK Mask command in M field. COL Pins for column-access control. MVER Control register - manufacturer ID. COL COLC,COLM,COLX packet on COL pins. NAP Power state - needs SCK/CMD wakeup. COLC Column operation packet on COL pins. NAPR Nap command in ROP field. COLM Write mask packet on COL pins. NAPRC Conditional nap command in ROP field. column Rows in a bank or activated row in sense amps have 2CBIT dualocts column storage. NAPXA NAPX register field - NAP exit delay A. NAPXB NAPX register field - NAP exit delay B. command A decoded bit-combination from a field. NOCOP No-operation command in COP field. COLX Extended operation packet on COL pins. NOROP No-operation command in ROP field. NOXOP No-operation command in XOP field. Page 60 storage cells in the current control Periodic operations to update the proper DR,DR4T,DR4F Device address field and packet framing fields in ROWA and ROWR packets. Preliminary Information Version 1.0 INFINEON Technologies Direct RAMBUS 72 Mbit (256kx18x16d) NSR INIT register field- NAP self-refresh. RQ Alternate name for ROW/COL pins. packet A collection of bits carried on the Channel. RSL Rambus Signaling Levels. PDN Power state - needs SCK/CMD wakeup. SAM PDNR Powerdown command in ROP field. SA PDNXA Control register - PDN exit delay A. Sample (IOL) command in XOP field. Serial address packet for control register transactions w/ SA address field. PDNXB Control register - PDN exit delay B. SBC Serial broadcast field in SRQ. SCK CMOS clock pin.. SD Serial data packet for control register transactions w/ SD data field. pin efficiency The fraction of non-idle cycles on a pin. PRE PREC,PRER,PREX precharge commands. PREC Precharge command in COP field. SDEV Serial device address in SRQ packet. precharge Prepares sense amp and bank for activate. SDEVID INIT register field - Serial device ID. PRER Precharge command in ROP field. self-refresh Refresh mode for PDN and NAP. PREX Precharge command in XOP field. sense amp Fast storage that holds copy of bank’s row. PSX INIT register field - PDN/NAP exit. SETF Set fast clock command from SOP field. PSR INIT register field - PDN self-refresh. SETR Set reset command from SOP field. PVER CNFGB register field - protocol version. SINT Q Read data packet on DQ pins. Serial interval packet for control register read/write transactions. R Row address field of ROWA packet. SIO0,SIO1 CMOS serial pins for control registers. RBIT CNFGB register field - # row address bits. SOP Serial opcode field in SRQ. RD/RDA Read (/precharge) command in COP field. SRD Serial read opcode command from SOP. read Operation of accesssing sense amp data. SRP INIT register field - Serial repeat bit. receive Moving information from the Channel into the RDRAM (a serial stream is demuxed). SRQ Serial request packet for control register read/write transactions. REFA Refresh-activate command in ROP field. STBY Power state - ready for ROW packets. REFB Control register - next bank (self-refresh). SVER Control register - stepping version. REFBIT CNFGA register field - ignore bank bits (for REFA and self-refresh). SWR Serial write opcode command from SOP. TCAS REFP Refresh-precharge command in ROP field. TCLS TCLSCAS register field - tCAS core delay. TCLSCAS register field - tCLS core delay. REFR Control register - next row for REFA. TCLSCAS refresh Periodic operations to restore storage cells. TCYCLE retire The automatic operation that stores write buffer into sense amp after WR command. TDAC RLX RLXC,RLXR,RLXX relax commands. RLXC Relax command in COP field. RLXR Relax command in ROP field. RLXX Relax command in XOP field. ROP Row-opcode field in ROWR packet. row Control register - tCAS and tCLS delays. Control register - tCYCLE delay. TEST77 Control register - tDAC delay. Control register - for test purposes. TEST78 Control register - for test purposes. TRDLY Control register - tRDLY delay. transaction ROW,COL,DQ packets for memory access. transmit Moving information from the RDRAM onto the Channel (parallel word is muxed). 2CBIT dualocts of cells (bank/sense amp). WR/WRA Write (/precharge) command in COP field. ROW Pins for row-access control write Operation of modifying sense amp data. ROW ROWA or ROWR packets on ROW pins. XOP Extended opcode field in COLX packet. ROWA Activate packet on ROW pins. ROWR Row operation packet on ROW pins. INFINEON Technologies Version 1.0 Preliminary Information Page 61 Direct RAMBUS 72 Mbit (256kx18x16d) Table Of Contents Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Key Timing Parameters/Part Numbers. . . . . . . . . . . . 1 Pinouts and Definitions . . . . . . . . . . . . . . . . . . . . . . . 2 Pin Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Packet Format . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6,7 Field Encoding Summary . . . . . . . . . . . . . . . . . . . . .8,9 DQ Packet Timing . . . . . . . . . . . . . . . . . . . . . . . . . . 10 COLM Packet to D Packet Mapping . . . . . . . . . . .10,11 ROW-to-ROW Packet Interaction . . . . . . . . . . . . 12, 13 ROW-to-COL Packet Interaction . . . . . . . . . . . . . . . 13 COL-to-COL Packet Interaction . . . . . . . . . . . . . . . . 14 COL-to-ROW Packet Interaction . . . . . . . . . . . . . . . 15 ROW-to-ROW Examples . . . . . . . . . . . . . . . . . . .16,17 Row and Column Cycle Description . . . . . . . . . . . . 17 Precharge Mechanisms . . . . . . . . . . . . . . . . . . . .18,19 Read Transaction - Example . . . . . . . . . . . . . . . . . . 20 Write Transaction - Example . . . . . . . . . . . . . . . . . . 21 Write/Retire - Examples . . . . . . . . . . . . . . . . . . . 22, 23 Interleaved Write - Example. . . . . . . . . . . . . . . . . . . 24 Interleaved Read - Example. . . . . . . . . . . . . . . . . . . 25 Interleaved RRWW. . . . . . . . . . . . . . . . . . . . . . . . . . 25 Control Register Transactions . . . . . . . . . . . . . . . . . 26 Control Register Packets . . . . . . . . . . . . . . . . . . . . . 27 Initialization . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-29 Control Register Summary. . . . . . . . . . . . . . . . . 30-37 Power State Management . . . . . . . . . . . . . . . . . 38-41 Refresh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 Current and Temperature Control . . . . . . . . . . . . . . 43 Electrical Conditions . . . . . . . . . . . . . . . . . . . . . . . . 44 Timing Conditions . . . . . . . . . . . . . . . . . . . . . . . .44-45 Electrical Characteristics . . . . . . . . . . . . . . . . . . . . . 46 Timing Characteristics . . . . . . . . . . . . . . . . . . . . . . . 46 RSL Clocking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 RSL - Receive Timing . . . . . . . . . . . . . . . . . . . . . . . 48 RSL - Transmit Timing . . . . . . . . . . . . . . . . . . . . . . . 49 CMOS - Receive Timing . . . . . . . . . . . . . . . . . . .50-51 CMOS - Transmit Timing . . . . . . . . . . . . . . . . . . .52-53 RSL - Domain Crossing Window . . . . . . . . . . . . . . . 53 Timing Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Absolute Maximum Ratings . . . . . . . . . . . . . . . . . . . 55 IDD - Supply Current Profile . . . . . . . . . . . . . . . . . . . 55 Page 62 Capacitance and Inductance . . . . . . . . . . . . . . . .56-57 Center-Bonded mBGA Package . . . . . . . . . . . . . . . 58 Glossary of Terms . . . . . . . . . . . . . . . . . . . . . . . .59-60 Preliminary Information Version 1.0 INFINEON Technologies