Direct RDRAM™ K4R571669D/K4R881869D 256/288Mbit RDRAM(D-die) 512K x 16/18bit x 32s banks Direct RDRAMTM Version 1.4 July 2002 Page -1 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Change History Version 1.4( July 2002) - First Copy ( Version 1.4 is named to unify the version of component and device operation datasheets) - Based on the 256/288Mb A-die RDRAM Version 1.4 Page 0 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Overview The RDRAM device is a general purpose high-performance memory device suitable for use in a broad range of applications including computer memory, graphics, video, and any other application where high bandwidth and low latency are required. SAMSUNG 230 K4RXXXX69D-Fxxx The 256/288-Mbit RDRAM devices are extremely highspeed CMOS DRAMs organized as 16M words by 16 or 18 bits. The use of Rambus Signaling Level (RSL) technology permits up to 1066 MHz transfer rates while using conventional system and board design technologies. RDRAM devices are capable of sustained data transfers up to 0.938ns per two bytes (7.5ns per sixteen bytes). The architecture of RDRAM devices allows the highest sustained bandwidth for multiple, simultaneous randomly addressed memory transactions. The separate control and data buses with independent row and column control yield over 95% bus efficiency. The RDRAM device's 32 banks support up to four simultaneous transactions. Figure 1: Direct RDRAM CSP Package System oriented features for mobile, graphics and large memory systems include power management, byte masking, and x18 organization. The two data bits in the x18 organization are general and can be used for additional storage and bandwidth or for error correction. The 256/288-Mbit RDRAM devices are offered in a CSP horizontal package suitable for desktop as well as lowprofile add-in card and mobile applications. Key Timing Parameters/Part Numbers Speed Features I/O Freq. MHz tRAC (Row Access Time) ns Part Number Bin -CT9 1066 32P K4R571669D-FbCcT9 -CN9 1066 32 K4R571669D-FCN9 -CM9 1066 35 K4R571669D-FCM9 -CM8 800 40 K4R571669D-FCM8 -CK8 800 45 K4R571669D-FCK8 -CT9 1066 32P K4R881869D-FCT9 -CN9 1066 32 K4R881869D-FCN9 -CM9 1066 35 K4R881869D-FCM9 -CM8 800 40 K4R881869D-FCM8 -CK8 800 45 K4R881869D-FCK8 Organization ♦ Highest sustained bandwidth per DRAM device - 2.1GB/s sustained data transfer rate - Separate control and data buses for maximized efficiency - Separate row and column control buses for easy scheduling and highest performance - 32 banks: four transactions can take place simultaneously at full bandwidth data rates 512Kx16x32sa ♦ Low latency features - Write buffer to reduce read latency - 3 precharge mechanisms for controller flexibility - Interleaved transactions 512Kx18x32s ♦ Advanced power management: - Multiple low power states allows flexibility in power consumption versus time to transition to active state - Power-down self-refresh ♦ Organization: 2kbyte pages and 32 banks, x 16/18 a.“32s” - 32 banks which use a “split” bank architecture. b.“F” - WBGA package. - x18 organization allows ECC configurations or increased storage/bandwidth - x16 organization for low cost applications c.“C” - RDRAM core uses normal power self refresh. ♦ Uses Rambus Signaling Level (RSL) for up to 1066MHz operation Page 1 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Pinouts and Definitions Center-Bonded Devices These tables shows the pin assignments of the center-bonded RDRAM package. The mechanical dimensions of this package are shown in a later section. Refer to Section “Center-Bonded WBGA Package” on page 18. Note - pin #1 is at the A1 position. Table 1: Center-Bonded Device (top view) 10 VDD GND VDD GND VDD VDD VDD VDD GND VDD 9 8 GND VDD CMD VDD GND GNDa GNDa VDD VDD GND GND VDD VDD GND GND VCMOS VDD GND 7 VDD DQA8 DQA7 DQA5 DQA3 DQA1 CTMN CTM RQ7 RQ5 RQ3 RQ1 DQB1 DQB3 DQB5 DQB7 DQB8 VDD 4 GND GND DQA6 DQA4 DQA2 DQA0 CFM CFMN RQ6 RQ4 RQ2 RQ0 DQB0 DQB2 DQB4 DQB6 GND GND 3 VDD GND SCK VCMOS GND VDD GND VDDa VREF GND VDD GND GND VDD SIO0 SIO1 GND VDD VDD GND GND VDD GND GND GND GND GND VDD B C E F G M N P S T 6 5 2 1 A D H J K L R U ROW COL SAMSUNG 230 K4RXXXX69D-Fxxx Top View Chip The pin #1(ROW 1, COL A) is located at the A1 position on the top side and the A1 position is marked by the marker “ ”. Page 2 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Table 2: Pin Description # Pins center Signal I/O Type SIO1,SIO0 I/O CMOSa 2 Serial input/output. Pins for reading from and writing to the control registers using a serial access protocol. Also used for power management. CMD I CMOSa 1 Command input. Pins used in conjunction with SIO0 and SIO1 for reading from and writing to the control registers. Also used for power management. SCK I CMOSa 1 Serial clock input. Clock source used for reading from and writing to the control registers VDD 24 Supply voltage for the RDRAM core and interface logic. VDDa 1 Supply voltage for the RDRAM analog circuitry. VCMOS 2 Supply voltage for CMOS input/output pins. GND 28 Ground reference for RDRAM core and interface. GNDa Description 2 Ground reference for RDRAM analog circuitry. I/O RSLb 9 Data byte A. Nine pins which carry a byte of read or write data between the Channel and the RDRAM device. DQA8 is not used (no connection) by RDRAM device with a x16 organization. CFM I RSLb 1 Clock from master. Interface clock used for receiving RSL signals from the Channel. Positive polarity. CFMN I RSLb 1 Clock from master. Interface clock used for receiving RSL signals from the Channel. Negative polarity 1 Logic threshold reference voltage for RSL signals DQA8..DQA0 VREF CTMN I RSLb 1 Clock to master. Interface clock used for transmitting RSL signals to the Channel. Negative polarity. CTM I RSLb 1 Clock to master. Interface clock used for transmitting RSL signals to the Channel. Positive polarity. RQ7..RQ5 or ROW2..ROW0 I RSLb 3 Row access control. Three pins containing control and address information for row accesses. RQ4..RQ0 or COL4..COL0 I RSLb 5 Column access control. Five pins containing control and address information for column accesses. I/O RSLb 9 Data byte B. Nine pins which carry a byte of read or write data between the Channel and the RDRAM device. DQB8 is not used (no connection) by RDRAM device with a x16 organization. DQB8.. DQB0 Total pin count per package 92 a. All CMOS signals are high-true; a high voltage is a logic one and a low voltage is logic zero. b. All RSL signals are low-true; a low voltage is a logic one and a high voltage is logic zero. Page 3 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D RQ7..RQ5 or ROW2..ROW0 3 DQB8..DQB0 9 RQ4..RQ0 or COL4..COL0 5 CTM CTMN SCK,CMD SIO0,SIO1 CFM CFMN 2 2 DQA8..DQA0 9 RCLK RCLK 1:8 Demux 1:8 Demux TCLK RCLK Control Registers Packet Decode ROWR ROWA 11 5 5 9 ROP DR BR AV Match DM 6 R REFR Power Modes Mux DEVID Packet Decode COLC 5 5 5 7 COLX 5 5 XOP DX BX COP DC BC M S Match Row Decode Match C COLM 8 MB MA Write Buffer XOP Decode PRER ACT 8 PREX Mux Mux Column Decode & Mask Bank 17 Bank 18 Bank 29 Bank 30 Bank 31 ••• 9 ••• ••• RCLK ••• SAmp SAmp SAmp 15 14/15 13/14 SAmp SAmp SAmp 17/18 16/17 16 ••• Bank 16 8:1 Mux SAmp SAmp SAmp 31 30/31 29/30 Bank 15 9 TCLK Write Buffer Bank 14 9 1:8 Demux 1:8 Demux Bank 13 9 Write Buffer TCLK Bank 2 72 SAmp SAmp SAmp 29/30 30/31 31 8:1 Mux Bank 1 Internal DQA Data Path SAmp SAmp SAmp 16 16/17 17/18 9 9 Bank 0 72 SAmp SAmp SAmp 13/14 14/15 15 9 9 64x72 RCLK 9 64x72 512x128x144 ••• 72 72 RD, WR PREC DRAM Core SAmp SAmp SAmp 0 0/1 1/2 Internal DQB Data Path SAmp SAmp SAmp 1/2 0/1 0 Sense Amp 64x72 9 Figure 2: 256/288-Mbit (512Kx16/18x32s) RDRAM Device Block Diagram Page 4 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D General Description Figure 2 is a block diagram of the 256/288-Mbit RDRAM device. It consists of two major blocks: a “core” block built from banks and sense amps similar to those found in other types of DRAM, and a Direct RambusTM interface block which permits an external controller to access this core at up to 2.1GB/s. Control Registers: The CMD, SCK, SIO0, and SIO1 pins appear in the upper center of Figure 2. They are used to write and read a block of control registers. These registers supply the RDRAM configuration information to a controller and they select the operating modes of the device. The REFR value is used for tracking the last refreshed row. Most importantly, the five bit DEVID specifies the device address of the RDRAM device on the Channel. Clocking: The CTM and CTMN pins (Clock-To-Master) generate TCLK (Transmit Clock), the internal clock used to transmit read data. The CFM and CFMN pins (Clock-FromMaster) generate RCLK (Receive Clock), the internal clock signal used to receive write data and to receive the ROW and COL pins. DQA,DQB Pins: These 16/18 pins carry read (Q) and write (D) data across the Channel. They are multiplexed/demultiplexed from/to two 64/72-bit data paths (running at one-eighth the data frequency) inside the RDRAM. Banks: The 32Mbyte core of the RDRAM device is divided into thirty two 1Mbyte banks, each organized as 512 rows, with each row containing 128 dualocts, and each dualoct containing 16/18 bytes. A dualoct is the smallest unit of data that can be addressed. Sense Amps: The RDRAM device contains 34 sense amps. Each sense amp consists of 1kbyte of fast storage (512 bytes for DQA and 512 bytes for DQB) and can hold onehalf of one row of one bank of the RDRAM device. The sense amp may hold any of the 1024 half-rows of an associated bank. However, each sense amp is shared between two adjacent banks of the RDRAM device (except for sense amps 0, 15, 16, and 31). This introduces the restriction that adjacent banks may not be simultaneously accessed. RQ Pins: These pins carry control and address information. They are broken into two groups. RQ7..RQ5 are also called ROW2..ROW0, and are used primarily for controlling row accesses. RQ4..RQ0 are also called COL4..COL0, and are used primarily for controlling column accesses. amps of the RDRAM device. These pins are de-multiplexed into a 24-bit ROWA (row-activate) or ROWR (row-operation) packet. COL Pins: The principle use of these five pins is to manage the transfer of data between the DQA/DQB pins and the sense amps of the RDRAM device. These pins are demultiplexed into a 23-bit COLC (column-operation) packet and either a 17-bit COLM (mask) packet or a 17-bit COLX (extended-operation) packet. ACT Command: An ACT (activate) command from an ROWA packet causes one of the 512 rows of the selected bank to be loaded to its associated sense amps (two 512 bytes sense amps for DQA and two for DQB). PRER Command: A PRER (precharge) command from an ROWR packet causes the selected bank to release its two associated sense amps, permitting a different row in that bank to be activated, or permitting adjacent banks to be activated. RD Command: The RD (read) command causes one of the 128 dualocts of one of the sense amps to be transmitted on the DQA/DQB pins of the Channel. WR Command: The WR (write) command causes a dualoct received from the DQA/DQB data pins of the Channel to be loaded into the write buffer. There is also space in the write buffer for the BC bank address and C column address information. The data in the write buffer is automatically retired (written with optional bytemask) to one of the 128 dualocts of one of the sense amps during a subsequent COP command. A retire can take place during a RD, WR, or NOCOP to another device, or during a WR or NOCOP to the same device. The write buffer will not retire during a RD to the same device. The write buffer reduces the delay needed for the internal DQA/DQB data path turnaround. PREC Precharge: The PREC, RDA and WRA commands are similar to NOCOP, RD and WR, except that a precharge operation is performed at the end of the column operation. These commands provide a second mechanism for performing precharge. PREX Precharge: After a RD command, or after a WR command with no byte masking (M=0), a COLX packet may be used to specify an extended operation (XOP). The most important XOP command is PREX. This command provides a third mechanism for performing precharge. ROW Pins: The principle use of these three pins is to manage the transfer of data between the banks and the sense Page 5 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Packet Format Figure 3 shows the formats of the ROWA and ROWR packets on the ROW pins. Table 3 describes the fields which comprise these packets. DR4T and DR4F bits are encoded to contain both the DR4 device address bit and a framing bit which allows the ROWA or ROWR packet to be recognized by the RDRAM device. The AV (ROWA/ROWR packet selection) bit distinguishes between the two packet types. Both the ROWA and ROWR packet provide a five bit device address and a five bit bank address. An ROWA packet uses the remaining bits to specify a nine bit row address, and the ROWR packet uses the remaining bits for an eleven bit opcode field. Note the use of the “RsvX” notation to reserve bits for future address field extension. Table 3: Field Description for ROWA Packet and ROWR Packet Field Description DR4T,DR4F Bits for framing (recognizing) a ROWA or ROWR packet. Also encodes highest device address bit. DR3..DR0 Device address for ROWA or ROWR packet. BR4..BR0 Bank address for ROWA or ROWR packet. RsvB denotes bits ignored by the RDRAM device. AV Selects between ROWA packet (AV=1) and ROWR packet (AV=0). R8..R0 Row address for ROWA packet. RsvR denotes bits ignored by the RDRAM device. ROP10..ROP0 Opcode field for ROWR packet. Specifies precharge, refresh, and power management functions. Figure 3 also shows the formats of the COLC, COLM, and COLX packets on the COL pins. Table 4 describes the fields which comprise these packets. The COLC packet uses the S (Start) bit for framing. A COLM or COLX packet is aligned with this COLC packet, and is also framed by the S bit. The 23 bit COLC packet has a five bit device address, a five bit bank address, a seven bit column address, and a four bit opcode. The COLC packet specifies a read or write command, as well as some power management commands. The remaining 17 bits are interpreted as a COLM (M=1) or COLX (M=0) packet. A COLM packet is used for a COLC write command which needs bytemask control. The COLM packet is associated with the COLC packet from at least tRTR earlier. A COLX packet may be used to specify an independent precharge command. It contains a five bit device address, a five bit bank address, and a five bit opcode. The COLX packet may also be used to specify some housekeeping and power management commands. The COLX packet is framed within a COLC packet but is not otherwise associated with any other packet. Table 4: Field Description for COLC Packet, COLM Packet, and COLX Packet Field Description S Bit for framing (recognizing) a COLC packet, and indirectly for framing COLM and COLX packets. DC4..DC0 Device address for COLC packet. BC4..BC0 Bank address for COLC packet. RsvB denotes bits reserved for future extension (controller drives 0 ’ s). C6..C0 Column address for COLC packet. RsvC denotes bits ignored by the RDRAM device. COP3..COP0 Opcode field for COLC packet. Specifies read, write, precharge, and power management functions. M Selects between COLM packet (M=1) and COLX packet (M=0). MA7..MA0 Bytemask write control bits. 1=write, 0=no-write. MA0 controls the earliest byte on DQA8..0. MB7..MB0 Bytemask write control bits. 1=write, 0=no-write. MB0 controls the earliest byte on DQB8..0. DX4..DX0 Device address for COLX packet. BX4..BX0 Bank address for COLX packet. RsvB denotes bits reserved for future extension (controller drives 0’ s). XOP4..XOP0 Opcode field for COLX packet. Specifies precharge, IOL control, and power management functions. Page 6 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D T0 T1 T2 T3 T8 CTM/CFM T9 T10 T11 CTM/CFM ROW2 DR4T DR2 BR0 BR3 RsvR R8 R5 R2 ROW2 DR4T DR2 BR0 BR3 ROW1 DR4F DR1 BR1 BR4 RsvR R7 R4 R1 ROW1 DR4F DR1 BR1 BR4 ROP9 ROP7 ROP4 ROP1 ROW0 DR3 DR0 BR2 RsvB AV=1 R6 R3 R0 ROW0 DR3 DR0 BR2 RsvB AV=0 ROP6 ROP3 ROP0 ROWA Packet T0 T1 T2 ROP10 ROP8 ROP5 ROP2 ROWR Packet T3 T0 T1 T2 T3 T4 T5 T6 T7 T8 T9 T10 T11 T12 T13 T14 T15 CTM/CFM CTM/CFM S=1 C6 C4 C5 C3 COL4 DC4 COL3 DC3 COL2 DC2 COP1 RsvB BC2 C2 COL1 DC1 COP0 BC4 BC1 C1 COL0 DC0 COP2 COP3 BC3 BC0 C0 ROW2 ..ROW0 ACT a0 COL4 ..COL0 WR b1 PRER c0 tPACKET MSK (b1) PREX d0 DQA8..0 DQB8..0 COLC Packet T8 T9 T10 T11 CTM/CFM a T12 T13 T14 T15 CTM/CFM COL4 S=1a MA7 MA5 MA3 MA1 COL4 S=1b DX4 XOP4 RsvB BX1 COL3 M=1 MA6 MA4 MA2 MA0 COL3 M=0 DX3 XOP3 BX4 BX0 COL2 MB7 MB4 MB1 COL2 DX2 XOP2 BX3 COL1 MB6 MB3 MB0 COL1 DX1 XOP1 BX2 COL0 MB5 MB2 COL0 DX0 XOP0 The COLM is associated with a previous COLC, and is aligned with the present COLC, indicated by the Start bit (S=1) position. b The COLM Packet COLX Packet COLX is aligned with the present COLC, indicated by the Start bit (S=1) position. Figure 3: Packet Formats Page 7 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Field Encoding Summary Table 5 shows how the six device address bits are decoded for the ROWA and ROWR packets. The DR4T and DR4F encoding merges a fifth device bit with a framing bit. When neither bit is asserted, the device is not selected. Note that a broadcast operation is indicated when both bits are set. Broadcast operation would typically be used for refresh and power management commands. If the device is selected, the DM (DeviceMatch) signal is asserted and an ACT or ROP command is performed. Table 5: Device Field Encodings for ROWA Packet and ROWR Packet DR4T DR4F Device Selection Device Match signal (DM) 1 1 All devices (broadcast) DM is set to 1 0 1 One device selected DM is set to 1 if {DEVID4..DEVID0} == {0,DR3..DR0} else DM is set to 0 1 0 One device selected DM is set to 1 if {DEVID4..DEVID0} == {1,DR3..DR0} else DM is set to 0 0 0 No packet present DM is set to 0 Table 6 shows the encodings of the remaining fields of the ROWA and ROWR packets. An ROWA packet is specified by asserting the AV bit. This causes the specified row of the specified bank of this device to be loaded into the associated sense amps. An ROWR packet is specified when AV is not asserted. An 11 bit opcode field encodes a command for one of the banks of this device. The PRER command causes a bank and its two associated sense amps to precharge, so another row or an adjacent bank may be activated. The REFA (refresh-activate) command is similar to the ACT command, except the row address comes from an internal register REFR, and REFR is incremented at the largest bank address. The REFP (refresh-precharge) command is identical to a PRER command. The NAPR, NAPRC, PDNR, ATTN, and RLXR commands are used for managing the power dissipation of the RDRAM device and are described in more detail in “Power State Management” on page 50. The TCEN and TCAL commands are used to adjust the output driver slew rate and they are described in more detail in “Current and Temperature Control” on page 56. Table 6: ROWA Packet and ROWR Packet Field Encodings ROP10..ROP0 Field DMa AV Name 10 9 - 8 - 7 - 6 - 5 - 4 - 3 0 - - 1 1 Row address - 1 0 1 1 0 0 0 xc x x 1 0 0 0 0 1 1 0 0 x Command Description 2:0 --- - No operation. ACT Activate row R8..R0 of bank BR4..BR0 of device and move device to ATTNb. 000 PRER Precharge bank BR4..BR0 of this device. 000 REFA Refresh (activate) row REFR8..REFR0 of bank BR4..BR0 of device. Increment REFR if BR4..BR0 = 11111 (see Figure 52). 1 0 1 0 1 0 1 0 0 x 000 REFP Precharge bank BR4..BR0 of this device after REFA (see Figure 52). 1 0 x x 0 0 0 0 1 x 000 PDNR Move this device into the powerdown (PDN) power state (see Figure 49). 1 0 x x 0 0 0 1 0 x 000 NAPR Move this device into the nap (NAP) power state (see Figure 49). 1 0 x x 0 0 0 1 1 x 000 NAPRC Move this device into the nap (NAP) power state conditionally 1 0 x x x x x x x 0 000 ATTNb Move this device into the attention (ATTN) power state (see Figure 47). 1 0 x x x x x x x 1 000 RLXR Move this device into the standby (STBY) power state (see Figure 48). 1 0 0 0 0 0 0 0 0 x 001 TCAL Temperature calibrate this device (see Figure 55). 1 0 0 0 0 0 0 0 0 x 010 TCEN Temperature calibrate/enable this device (see Figure 55). 1 0 0 0 0 0 0 0 0 0 000 NOROP No operation. a. The DM (Device Match signal) value is determined by the DR4T,DR4F, DR3..DR0 field of the ROWA and ROWR packets. See Table 5. b. The ATTN command does not cause a RLX-to-ATTN transition for a broadcast operation (DR4T/DR4F=1/1). c. An “x” entry indicates which commands may be combined. For instance, the three commands PRER/NAPRC/RLXR may be specified in one ROP value (011000111000). Page 8 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Table 7 shows the COP field encoding. The device must be in the ATTN power state in order to receive COLC packets. The COLC packet is used primarily to specify RD (read) and WR (write) commands. Retire operations (moving data from the write buffer to a sense amp) happen automatically. See Figure 18 for a more detailed description. The COLC packet can also specify a PREC command, which precharges a bank and its associated sense amps. The RDA/WRA commands are equivalent to combining RD/WR with a PREC. RLXC (relax) performs a power mode transition. See “Power State Management” on page 50. Table 7: COLC Packet Field Encodings S DC4.. DC0 (select device)a COP3..0 Name Command Description 0 ---- ----- - No operation. 1 /= (DEVID4 ..0) ----- - Retire write buffer of this device. 1 == (DEVID4 ..0) x000b NOCOP Retire write buffer of this device. 1 == (DEVID4 ..0) x001 WR Retire write buffer of this device, then write column C6..C0 of bank BC4..BC0 to write buffer. 1 == (DEVID4 ..0) x010 RSRV Reserved, no operation. 1 == (DEVID4 ..0) x011 RD Read column C6..C0 of bank BC4..BC0 of this device. 1 == (DEVID4 ..0) x100 PREC Retire write buffer of this device, then precharge bank BC4..BC0 (see Figure 15). 1 == (DEVID4 ..0) x101 WRA Same as WR, but precharge bank BC4..BC0 after write buffer (with new data) is retired. 1 == (DEVID4 ..0) x110 RSRV Reserved, no operation. 1 == (DEVID4 ..0) x111 RDA Same as RD, but precharge bank BC4..BC0 afterward. 1 == (DEVID4 ..0) 1xxx RLXC Move this device into the standby (STBY) power state (see Figure 48). a. “/=” means not equal, “==” means equal. b. An “x” entry indicates which commands may be combined. For instance, the two commands WR/RLXC may be specified in one COP value (1001). Table 8 shows the COLM and COLX field encodings. The M bit is asserted to specify a COLM packet with two 8 bit bytemask fields MA and MB. If the M bit is not asserted, an COLX is specified. It has device and bank address fields, and an opcode field. The primary use of the COLX packet is to permit an independent PREX (precharge) command to be specified without consuming control bandwidth on the ROW pins. It is also used for the CAL(calibrate) and SAM (sample) current control commands (see “Current and Temperature Control” on page 56), and for the RLXX power mode command (see “Power State Management” on page 50). Table 8: COLM Packet and COLX Packet Field Encodings M DX4 .. DX0 (selects device) XOP4..0 Name Command Description 1 ---- - MSK MB/MA bytemasks used by WR/WRA. 0 /= (DEVID4 ..0) - - No operation. 0 == (DEVID4 ..0) 00000 NOXOP No operation. 0 == (DEVID4 ..0) 1xxx0a PREX Precharge bank BX3..BX0 of this device (see Figure 15). 0 == (DEVID4 ..0) x10x0 CAL Calibrate (drive) IOL current for this device (see Figure 54). 0 == (DEVID4 ..0) x11x0 CAL/SAM Calibrate (drive) and Sample ( update) IOL current for this device (see Figure 54). 0 == (DEVID4 ..0) xxx10 RLXX Move this device into the standby (STBY) power state (see Figure 48). 0 == (DEVID4 ..0) xxxx1 RSRV Reserved, no operation. a. An “x” entry indicates which commands may be combined. For instance, the two commands PREX/RLXX may be specified in one XOP value (10010). Page 9 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Electrical Conditions Table 9: Electrical Conditions Symbol Parameter and Conditions Min Max Unit - 100 °C 2.50 - 0.13 2.50 + 0.13 V TJ Junction temperature under bias VDD, VDDA Supply voltage VDD,N, VDDA,N Supply voltage droop (DC) during NAP interval (tNLIMIT) - 2.0 % vDD,N, vDDA,N Supply voltage ripple (AC) during NAP interval (tNLIMIT) -2.0 2.0 % VCMOSa Supply voltage for CMOS pins (2.5V controllers) Supply voltage for CMOS pins (1.8V controllers) VDD 1.80 - 0.1 VDD 1.80 + 0.2 V V VREF Reference voltage 1.40 - 0.2 1.40 + 0.2 V VDIL RSL data input - low voltage @ tCYCLE=1.875ns VREF - 0.5 VREF - 0.15 RSL data input - low voltage @ tCYCLE=2.50ns VREF - 0.5 VREF - 0.2 VREF + 0.15 VREF + 0.5 VREF + 0.2 VREF + 0.5 V VDIH RSL data input - high voltageb @ tCYCLE=1.875ns RSL data input - high voltageb V @ tCYCLE=2.50ns RDA RSL data asymmetry : RDA = (VDIH - VREF) / (VREF - VDIL) 0.67 1.00 - VCM RSL clock input - common mode VCM = (VCIH+VCIL)/2 1.3 1.8 V VCIS,CTM RSL clock input swing: VCIS = VCIH - VCIL (CTM,CTMN pins). 0.35 1.00 V VCIS,CFM RSL clock input swing: VCIS = VCIH - VCIL (CFM,CFMN pins). 0.225 1.00 V 0.3c VCMOS/2 - 0.25 VIL,CMOS VIH,CMOS CMOS input low voltage - CMOS input high voltage VCMOS/2 + 0.25 VCMOS+0.3 d V V a. VCMOS must remain on as long as VDD is applied and cannot be turned off. b. VDIH is typically equal to VTERM (1.8V±0.1V) under DC conditions in a system. c. Voltage undershoot is limited to -0.7V for a duration of less than 5ns. d. Voltage overshoot is limited toVCMOS +0.7V for a duration of less than 5ns Page 10 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Electrical Characteristics Table 10: Electrical Characteristics Symbol Parameter and Conditions ΘJC Junction-to-Case thermal resistance IREF VREF current @ VREF,MAX IOH RSL output high current @ (0≤VOUT≤VDD) RSL IOL current @ tCYCLE= 1.875ns VOL = 0.9V, VDD,MIN , TJ,MAX IALL RSL IOL current @ tCYCLE= 2.50ns VOL = 0.9V, VDD,MIN , TJ,MAX ∆IOL RSL IOL current resolution step rOUT Dynamic output impedance @ VOL= 0.9V IOL,NOM RSL IOL current @ VOL = 1.0V RSL IOL current @ VOL = b,c@ 1.0Vb,c tCYCLE=1.875ns a a Min Max Unit - 0.5 °C/Watt -10 10 µA -10 10 µA 32.0 90.0 30.0 90.0 - 1.5 mA 150 - Ω 27.1 30.1 26.6 30.6 -10.0 10.0 µA - 0.3 V VCMOS-0.3 - V mA mA @ tCYCLE=2.50ns II,CMOS CMOS input leakage current @ (0≤VI,CMOS≤VCMOS) VOL,CMOS CMOS output voltage @ IOL,CMOS= 1.0mA VOH,CMOS CMOS output high voltage @ IOH,CMOS= -0.25mA a. This measurement is made in manual current control mode; i.e. with all output device legs sinking current. b. This measurement is made in automatic current control mode after at least 64 current control calibration operations to a device and after CCA and CCB are initialized to a value of 64. This value applies to all DQA and DQB pins. c. This measurement is made in automatic current control mode in a 25Ω test system with VTERM= 1.714V and VREF= 1.357V and with the ASYMA and ASYMB register fields set to 0. Page 11 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Timing Conditions Table 11: Timing Conditions Symbol Parameter Min Max Unit Figure(s) CTM and CFM cycle times (-1066) 1.875 2.5 CTM and CFM cycle times (-800) 2.50 3.33 ns Figure 56 tCR, tCF CTM and CFM input rise and fall times. Use the minimum value of these parameters during testing. 0.2 0.5 ns Figure 56 tCH, tCL CTM and CFM high and low times 40% 60% tCYCLE Figure 56 CTM-CFM differential (MSE/MS=0/0) CTM-CFM differential (MSE/MS=1/1)a 0.0 0.9 1.0 1.0 tCYCLE CTM-CFM differential only for 1.875ns (MSE/MS=1/0) -0.1 0.1 tDCW Domain crossing window -0.1 0.1 tCYCLE Figure 62 tDR, tDF DQA/DQB/ROW/COL input rise/fall times (20% to 80%). Use the minimum value of these parameters during testing. 0.2 0.45 ns Figure 57 DQA/DQB/ROW/COL-to-CFM set/hold @ t CYCLE=1.875ns 0.160b - 0.200b.c ns Figure 57 DQA/DQB/ROW/COL-to-CFM set/hold @ t CYCLE=2.50ns - tCYCLE tTR tS, tH Figure 43 Figure 56 tDR1, tDF1 SIO0, SIO1 input rise and fall times - 5.0 ns Figure 59 tDR2, tDF2 CMD, SCK input rise and fall times - 2.0 ns Figure 59 1000 - SCK cycle time - Power transitions @ t CYCLE=1.875ns 7.5 - ns Figure 59 SCK cycle time - Power transitions @ t CYCLE=2.50ns 10 - SCK high and low times @ t CYCLE=1.875ns 3.5 ns Figure 59 SCK high and low times @ t CYCLE=2.50ns 4.25 - CMD setup time to SCK rising or falling edged @ t CYCLE=1.875ns 1.0 ns Figure 59 1.25 - SCK cycle time - Serial control register transactions tCYCLE1 tCH1, tCL1 tS1 CMD setup time to SCK rising or falling edged @ t CYCLE=2.50ns tH1 CMD hold time to SCK rising or falling edged 1 - ns Figure 59 tS2 SIO0 setup time to SCK falling edge 40 - ns Figure 59 tH2 SIO0 hold time to SCK falling edge 40 - ns Figure 59 tS3 PDEV setup time on DQA5..0 to SCK rising edge. 0 - ns Figure 50 tH3 PDEV hold time on DQA5..0 to SCK rising edge. 5.5 - ns Figure 60 tS4 ROW2..0, COL4..0 setup time for quiet window -1 - tCYCLE Figure 50 tH4 ROW2..0, COL4..0 hold time for quiet windowe 5 - tCYCLE Figure 50 tNPQ Quiet on ROW/COL bits during NAP/PDN entry 4 - tCYCLE Figure 49 tREADTOCC Offset between read data and CC packets (same device) 12 - tCYCLE Figure 54 tCCSAMTOREAD Offset between CC packet and read data (same device) 8 - tCYCLE Figure 54 tCE CTM/CFM stable before NAP/PDN exit 2 - tCYCLE Figure 50 Page 12 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Table 11: Timing Conditions Symbol Parameter Min Max Unit Figure(s) tCD CTM/CFM stable after NAP/PDN entry 100 - tCYCLE Figure 49 tFRM ROW packet to COL packet ATTN framing delay 7 - tCYCLE Figure 48 tNLIMIT Maximum time in NAP mode 10.0 µs Figure 47 tREF Refresh interval 32 ms Figure 52 tBURST Interval after PDN or NAP (with self-refresh) exit in which all banks of the RDRAM device must be refreshed at least once. 200 µs Figure 53 tCCTRL Current control interval 100ms ms/tCYCLE Figure 54 tTEMP Temperature control interval 100 ms Figure 55 tTCEN TCE command to TCAL command 150 - tCYCLE Figure 55 tTCAL TCAL command to quiet window 2 2 tCYCLE Figure 55 tTCQUIET Quiet window (no read data) 140 - tCYCLE Figure 55 tPAUSE RDRAM device delay (no RSL operations allowed) 200.0 µs page 38 34 tCYCLE a. MSE/MS are fields of the SKIP register. For this combination (skip override) the tDCW parameter range is effectively 0.0 to 0.0. b. tS,MIN and tH,MIN for other tCYCLE values can be interpolated between or extrapolated from the timings at the 2 specified t CYCLE values. c. This parameter also applies to a-1066 part when operated with tCYCLE = 2.50ns d. With VIL,CMOS=0.5VCMOS-0.4V and VIH,CMOS=0.5VCMOS+0.4V e. Effective hold becomes tH4’=tH4+[PDNXA•64•tSCYCLE+tPDNXB,MAX]-[PDNX•256•tSCYCLE] if [PDNX•256•tSCYCLE] < [PDNXA•64•tSCYCLE+tPDNXB,MAX]. See Figure 50. Page 13 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Timing Characteristics Table 12: Timing Characteristics Symbol Parameter Min Max CTM-to-DQA/DQB output time @ tCYCLE=1.875ns -0.195a +0.195a CTM-to-DQA/DQB output time @ tCYCLE=2.5ns -0.260a,b +0.260a,b DQA/DQB output rise and fall times @ tCYCLE=1.875ns 0.2 0.32 DQA/DQB output rise and fall times @ tCYCLE=2.5ns 0.2 0.45 tQ tQR, tQF Unit Figure(s) ns Figure 58 ns Figure 58 tQ1 SCK(neg)-to-SIO0 delay @ CLOAD,MAX = 20pF (SD read data valid). - 10 ns Figure 61 tHR SCK(pos)-to-SIO0 delay @ CLOAD,MAX = 20pF (SD read data hold). 2 - ns Figure 61 tQR1, tQF1 SIOOUT rise/fall @ CLOAD,MAX = 20pF - 12 ns Figure 61 tPROP1 SIO0-to-SIO1 or SIO1-to-SIO0 delay @ CLOAD,MAX = 20pF - 20 ns Figure 61 tNAPXA NAP exit delay - phase A - 50 ns Figure 50 tNAPXB NAP exit delay - phase B - 40 ns Figure 50 tPDNXA PDN exit delay - phase A - 4 µs Figure 50 tPDNXB PDN exit delay - phase B - 9000 tCYCLE Figure 50 tAS ATTN-to-STBY power state delay - 1 tCYCLE Figure 48 tSA STBY-to-ATTN power state delay - 0 tCYCLE Figure 48 tASN ATTN/STBY-to-NAP power state delay - 8 tCYCLE Figure 49 tASP ATTN/STBY-to-PDN power state delay - 8 tCYCLE Figure 49 a. tQ,MIN and tQ,MAX for other tCYCLE values can be interpolated between or extrapolated from the timings at the 3 specified tCYCLE values. b.This parameter also applies to a-1066 part when operated with tCYCLE = 2.50ns Page 14 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Timing Parameters Table 13: Timing Parameter Summary Parameter Min Min Min Min -32P -32 -35 -40 -1066 -1066 -1066 -800 Description Min -45 -800 Max Units Figure(s) tRC Row Cycle time of RDRAM banks -the interval between ROWA packets with ACT commands to the same bank. 28 28 32 28 28 - tCYCLE Figure 16 Figure 17 tRAS RAS-asserted time of RDRAM bank - the interval between ROWA packet with ACT command and next ROWR packet with PRERa command to the same bank. 20 20 22 20 20 64µsb tCYCLE Figure 16 Figure 17 tRP Row Precharge time of RDRAM banks - the interval between ROWR packet with PRERa command and next ROWA packet with ACT command to the same bank. 8 8 10 8 8 - tCYCLE Figure 16 Figure 17 tPP Precharge-to-precharge time of RDRAM device - the interval between successive ROWR packets with PRERa commands to any banks of the same device. 8 8 8 8 8 - tCYCLE Figure 13 tRR RAS-to-RAS time of RDRAM device - the interval between successive ROWA packets with ACT commands to any banks of the same device. 8 8 8 8 8 - tCYCLE Figure 14 tRCD RAS-to-CAS Delay - the interval from ROWA packet with ACT command to COLC packet with RD or WR command). Note - the RAS-toCAS delay seen by the RDRAM core (tRCD-C) is equal to tRCD-C = 1 + tRCD because of differences in the row and column paths through the RDRAM interface. 9 9 9 7 9 - tCYCLE Figure 16 Figure 17 tCAC CAS Access delay - the interval from RD command to Q read data. The equation for tCAC is given in the TPARM register in Figure 40. 8 9 9 8 8 12 tCYCLE Figure 5 Figure 40 tCWD CAS Write Delay (interval from WR command to D write data. 6 6 6 6 6 6 tCYCLE Figure 5 tCC CAS-to-CAS time of RDRAM bank - the interval between successive COLC commands). 4 4 4 4 4 - tCYCLE Figure 16 Figure 17 tPACKET Length of ROWA, ROWR, COLC, COLM or COLX packet. 4 4 4 4 4 4 tCYCLE Figure 3 tRTR Interval from COLC packet with WR command to COLC packet which causes retire, and to COLM packet with bytemask. 8 8 8 8 8 - tCYCLE Figure 18 tOFFP The interval (offset) from COLC packet with RDA command, or from COLC packet with retire command (after WRA automatic precharge), or from COLC packet with PREC command, or from COLX packet with PREX command to the equivalent ROWR packet with PRER. The equation for tOFFP is given in the TPARM register in Figure 40. 4 4 4 4 4 4 tCYCLE Figure 15 Figure 40 tRDP Interval from last COLC packet with RD command to ROWR packet with PRER. 4 4 4 4 4 - tCYCLE Figure 16 tRTP Interval from last COLC packet with automatic retire command to ROWR packet with PRER. 4 4 4 4 4 - tCYCLE Figure 17 a. Or equivalent PREC or PREX command. See Figure 15. b. This is a constraint imposed by the core, and is therefore in units of µs rather than tCYCLE. Page 15 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Absolute Maximum Ratings Table 14: Absolute Maximum Ratings Symbol Parameter Min Max Unit VI,ABS Voltage applied to any RSL or CMOS pin with respect to Gnd - 0.3 VDD+0.3 V VDD,ABS, VDDA,ABS Voltage on VDD and VDDA with respect to Gnd - 0.5 VDD+1.0 V TSTORE Storage temperature - 50 100 °C TMIN Minimum operation temperature 0 Note* °C Note*) Component : refer to TJ,ΘJC RIMM: refre to TPLATE, MAX IDD - Supply Current Profile Table 15: Supply Current Profile Min Max (1066MHz, 32P/-32/-35) Max (800MHz, -40/-45) Unit Device in PDN, self-refresh enabled and INIT.LSR=0. - 6000 6000 µA IDD,NAP Device in NAP. - 4 4 mA IDD,STBY Device in STBY. This is the average for a device in STBY with (1) no packets on the Channel, and (2) with packets sent to other devices. - 100 80 mA IDD,REFRESH Device in STBY and refreshing rows at the tREF,MAX period. - 100 80 mA IDD,ATTN Device in ATTN. This is the average for a device in ATTN with (1) no packets on the Channel, and (2) with packets sent to other devices. - 150 120 mA IDD,ATTN-W Device in ATTN. ACT command every 8•tCYCLE, PRE command every 8•tCYCLE, WR command every 4•tCYCLE, and data is 1100..1100 - 790(x18)b 620(x18) mA 730(x16) 575(x16) Device in ATTN. ACT command every 8•tCYCLE, PRE command every 8•tCYCLE, RD command every 4•tCYCLE, and data is 1111..1111c - 700(x18) 560(x18) 650(x16) 530(x16) IDD value RDRAM Power State and Steady-State Transaction Ratesa IDD,PDN IDD,ATTN-R mA a. CMOS interface consumes power in all power states. b. x18/x16 RDRAM data width. c. This does not include the IOL sink current. The RDRAM dissipates IOL•VOL in each output driver when a logic one is driven. Table 16: Supply Current at Initialization Symbol Parameter Allowed Range of tCYCLE VDD Min Max Unit mA mA IDD,PWRUP,D IDD from power -on to SETR 1.875ns to 2.5ns VDD,MIN - 200a IDD,SETR,D IDD from SETR to CLRR 1.875ns to 2.5ns VDD,MIN - 332 a. The supply current will be 150mA when tCYCLE is in the range 15ns to 1000ns. Page 16 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Capacitance and Inductance Table 17: RSL Pin Parasitics Symbol LI L12 Parameter and Conditions - RSL pins Min Max Unit Figure RSL effective input inductance @ tCYCLE=1.875ns - 3.5 RSL effective input inductance @ tCYCLE=2.5ns - 4.0 nH Figure 63 Mutual inductance between any DQA or DQB RSL signals. - 0.2 nH Mutual inductance between any ROW or COL RSL signals. - 0.6 nH Difference in LI value between any RSL pins of a single device. - 1.8 nH Figure 63 2.0 2.3 pF Figure 63 2.0 2.4 Figure 63 ∆LI RSL effective input capacitancea @ tCYCLE=1.875ns CI RSL effective input capacitancea @ t CYCLE=2.5ns C12 Mutual capacitance between any RSL signals. - 0.1 pF Figure 63 ∆CI Difference in CI value between average of {CTM, CTMN, CFM, CFMN} and any RSL pins of a single device. - 0.06 pF Figure 63 RSL effective input resistance @ tCYCLE=1.875ns 4 10 Ω Figure 63 RSL effective input resistance @ tCYCLE=2.5ns 4 15 Min Max Unit Figure RI a. This value is a combination of the device IO circuitry and package capacitances Table 18: CMOS Pin Parasitics Symbol Parameter and Conditions - CMOS pins LI ,CMOS CMOS effective input inductance CI ,CMOS CMOS effective input capacitance (SCK,CMD)a CI ,CMOS,SIO CMOS effective input capacitance (SIO1, SIO0)a 8.0 nH 1.7 2.1 pF - 7.0 pF Figure 63 a. This value is a combination of the device IO circuitry and package capacitances. Page 17 Version 1.4 July 2002 Direct RDRAM™ K4R571669D/K4R881869D Center-Bonded WBGA Package (92balls) Figure 4 shows the form and dimensions of the recommended package for the 92balls center-bonded WBGA device class. D A B C D E F Bottom G H J K L M N P R S T U Bottom Top 1 2 3 4 A 5 6 7 8 e2 9 10 d e1 Bottom E E1 Figure 4: Center-Bonded WBGA Package Table lists the numerical values corresponding to dimensions shown in Figure 4. Table 19: Center-Bonded WBGA Package Dimensions Symbol Parameter Min. Max. Unit e1 Ball pitch (x-axis) 0.80 0.80 mm e2 Ball pitch (y-axis) 0.80 0.80 mm A Package body length 9.2 9.4 mm D Package body width 15.0 15.2 mm E Package total thickness 0.98 1.08 mm E1 Ball height 0.30 0.40 mm d Ball diameter 0.40 0.50 mm Page 18 Version 1.4 July 2002