ETC IA05BSF10POHT-K

Proximity Sensors Inductive
High Temperature
Types IA, M5, 8, NPN/PNP
• Stainless steel housings
• Sensing distance: 0.8 - 1 mm
• Power supply: 10 to 30 VDC
• Output: Transistor NPN or PNP, make switching
• For flush mounting
• 2 m silicone cable
Product Description
Ordering Key IA 05 BSF 08 NO HT-K
Inductive proximity sensor
with transistor output in M5
and M8 stainless steel housing
for flush mounting in metal.
Type: Ind. prox. switch
Housing style
Housing size
Housing material
Housing length
Detection principle
Sensing distance
Output type
Output configuration
High temperature
Output configuration for
NPN/PNP with NO as standard. Connection with 2 m
silicone cable.
Type Selection
Rated
operating
dist. (Sn)
Connection
type
Housing
dimensions
Ordering no.
Transistor NPN
Make switching
Ordering no.
Transistor PNP
Make switching
0.8 mm
1.0 mm
Cable, 2 m
Cable, 2 m
M5
M8
IA 05 BSF 08 NOHT-K
IA 08 BSF 10 NOHT-K
IA 05 BSF 08 POHT-K
IA 08 BSF 10 POHT-K
Ambient temperature
Operating
Storage
Degree of protection
Housing material
CE-marking
Connection
-25 to +120°C (-13 to +248°F)
-30 to +125°C (-22 to +257°F)
IP 67 (Nema 1, 3, 4, 6, 13)
Stainless steel
Yes
Cable, silicone, 2 m, AWG 26
All types for flush mounting in metal
Specifications
Rated operational volt. (UB)
Ripple
Rated operational current (Ie)
Continuous
No-load supply current (Io)
Voltage drop (Ud)
Frequency of op. cycles (f)
Effective operating dist. (Sr)
Usable operating dist. (Su)
10 to 30 VDC (ripple included)
≤ 10%
≤ 50 mA @ + 25°C (+75°F)
≤ 5 mA (ON)
< 3,0 V (@ Imax)
Ø5: 3 kHz
Ø8: 2 kHz
0.9 x Sn ≤ Sr ≤ 1.1 x Sn
0.85 x Sr ≤ Su ≤ 1.15 x Sr
Specifications are subject to change without notice (07.12.00)
1
IA M5, 8, NPN/PNP
Dimensions
Wiring Diagrams
M8 x 1
M5 x 0,5
1 BN
+
1 BN
+
4 BK
25
30
45
4 BK
3 BU
IA 05 BSF 08 .OHT-K
IA 08 BSF 10 .OHT-K
3 BU
-
NPN - Make switching
-
PNP - Make switching
Installation Hints
To avoid interference from inductive voltage/
current peaks, separate the prox. switch power cables from any other power cables, e.g.
motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Incorrect
Correct
The cable should not be pulled
2
Specifications are subject to change without notice (07.12.00)