ETC EZE480A18

Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
•
•
•
•
nect terminals. The Series EZ is the
preferred choice for replacement of
120V and 240V Electro-mechanical
relays. Output consists of an SCR
switch and is available in Zero-Cross
and Random Turn-On (Phase
Controlable) versions.
Manufactured in Crydom’s ISO 9001
Certified facility for optimum product
performance and reliability.
Low Leakage
Quick Connect Terminals
SCR Output
24V Control Available
(EZE Models)
The Series EZ SPST-NO AC output
relays offer a low profile package
with the convenience of quick con-
AC CONTROL (120Vac)
(24Vac)
MODEL NUMBERS
DC CONTROL (5Vdc)
(24Vdc)
EZ240A12
EZE240A12
EZ240A18
EZE240A18
EZ480A12
EZE480A12
EZ480A18
EZE480A18
EZ240D5
EZ240D12
EZE240D12
EZ240D18
EZE240D18
EZ480D12
EZE480D12
EZ480D18
EZE480D18
24-280
24-280
24-280
48-660
48-660
OUTPUT SPECIFICATIONS ➀
Operating Voltage (47-63 Hz) [Vrms]
5
12
18
12
18
Min. Load Current, [mArms]
150
150
150
150
150
Transient Overvoltage [Vpk]
600
600
600
1200
1200
Max. Surge Current, (16.6ms) [Apk]
40
150
200
150
200
Max. On-State Voltage Drop @ Rated Current [Vpk]
1.5
1.5
1.5
1.5
1.5
Thermal Resistance Junction to Case (R θJC) [°C/W]
2.0
2.0
1.1
2.0
1.1
Maximum I 2 t for Fusing, (8.3 msec.) [A 2sec]
95
95
170
95
170
Max. Off-State Leakage Current @
Rated Voltage [mArms] ➄
0.1
0.1
0.1
0.1
0.1
Min. Off-State dv/dt @ Max. Rated Voltage [V/ µsec] ➁
500
500
500
500
500
0.5
0.5
Max. Load Current ➃ [Arms]
Max. Turn-On Time
➅
1/2 Cycle (DC Input), 10.0 msec (AC Input)
1/2 Cycle (DC Input), 40.0 msec (AC Input)
Max. Turn-Off Time
0.5
Power Factor (Min.) with Max. Load
INPUT SPECIFICATIONS ➀
Nominal Voltage
0.5
0.5
DC CONTROL
5Vdc
5Vdc
5Vdc
AC CONTROL
EZ240D05
EZ240D12
EZ240D18
EZ480D12
EZ480D18
24Vdc
EZE240D12
EZE240D18
EZE480D12
EZE480D18
Control Voltage Range
4-15 Vdc
3-15 Vdc
4-15 Vdc
15-32 Vdc
90-140 Vrms
18-36 Vrms
Max. Turn-On Voltage
4.0 Vdc
3.0 Vdc
4.0 Vdc
15.0 Vdc
90.0 Vrms
18.0 Vrms
Min. Turn-Off Voltage
1.0 Vdc
1.0 Vdc
1.0 Vdc
1.0 Vdc
10.0 Vrms
2.0 Vrms
300 Ohms
300 Ohms
240 Ohms
1500 Ohms
10.6k Ohms
1.8k Ohms
13 mAdc
15 mAdc
15 mAdc
15 mAdc
10 mArms
10 mArms
MODEL NUMBERS
Nominal Input Impedance
Typical Input Current @ Nominal Voltage
GENERAL NOTES
➀
➁
➂
➃
➄
120Vac
EZ240A12
EZ240A18
EZ480A12
EZ480A18
24Vac
EZE240A12
EZE240A18
EZE480A12
EZE480A18
©2000 CRYDOM CORP, Specifications subject to change without notice.
All parameters at 25° C unless otherwise specified.
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
240V, DC control models only, all others 2500Vrms.
Heat sinking required, for derating curves see page 2.
For recommended applications and more information contact:
Off-State leakage for snubbered
USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280
version (suffix S) is 10.0 mArms.
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: [email protected]
➅ Turn-on time for random turn-on versions
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
is 0.1 msec (DC Control Models).
UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House
FastFax Document No.160
Brook Road, Wimborne, Dorset, England BH21 2BH, Email: [email protected].
SERIES EZ.101000, PAGE 1 OF 2
GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH
Series EZ
5-18Amp • 120/240, 480 Vac • AC Output
GENERAL SPECIFICATIONS
Dielectric Strength ➂ 50/60Hz Input/Output/Base
4000 Vrms*
109 Ohm
Insulation Resistance (Min.) @ 500 Vdc
Max. Capacitance Input/Output
8 pF
Ambient Operating Temperature Range
-40 to 80°C
Ambient Storage Temperature Range
-40 to 125°C
MECHANICAL SPECIFICATIONS
Weight: (typical)
1.5 oz. (43g)
Encapsulation:
Thermally Conductive Epoxy
Terminals:
.25 Inch Faston
AVAILABLE OPTIONS
*240V, DC Control Models Only.
2.63
(66.8)
S
Internal Snubber
Example: EZ240D12S
R
Random Turn-On Switching (240V Only)
Example: EZ240D12R, EZ240D12RS
EZ240D5R
2.24
(56.9)
1
1.00
(25.4)
2
OUTPUT
.49
(12.4)
SOLID-STATE RELAY
3+
1.50
(38.1)
PIN
PIN
PIN
PIN
4
INPUT
FASTON
TERMINAL
.250 X .032
4 PLCS.
Crydom Heat Sinks offer excellent thermal management and are perfectly
matched to the load current ratings of
Crydom panel mount relays. Request
Crydom’s Heat Sink specification sheet for
all the details.
.197 DIA.
(2 PLCS)
1:
2:
3:
4:
AC LOAD
AC LOAD
+DC CONTROL
--- DC CONTROL
.40
(10.2)
1.73
(43.9)
.12
(3.0)
.95
(24.1)
All dimensions are in inches (millimeters)
CURRENT DERATING CURVES
12A
5A
18
2
120
10
6°C/W
116
NO HEATSINK
5
120
2°C/W
12
5°C/W
116
NO HEATSINK
6
112
120
1
124
0
1
2
3
4
5
Load Current [Arms]
10
20
40
60
80
Max Ambient Temp. [°C]
2
4
6
8
10
Load Current [Arms]
12
20
40
60
80
Max Ambient Temp. [°C]
124
0
3
6
9
12
15
Load Current [Arms]
18
20
40
60
80
Max Ambient Temp. [°C]
©2000 CRYDOM CORP, Specifications subject to change without notice.
APPROVALS
UL
E116950
CSA LR81689
VDE 10139 UG (240V DC Control Only)
FastFax Document No.160
SERIES EZ.101000, PAGE 2 OF 2
For recommended applications and more information contact:
USA: (800) 8 CRYDOM • (800) 827-9366 •(619) 715-7200 • fax (619) 715-7280
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • Email: [email protected]
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191
UK: (44)1202 857300 • fax (44)1202 857340 Crydom International Ltd., Riverside House
Brook Road, Wimborne, Dorset, England BH21 2BH, Email: [email protected].
GERMANY: 0180 3000 506 • fax (49)(0)6874 182585 Crydom GmbH,
Base Plate Temp [°C]
115
112
4°C/W
Power Dissipation [W]
NO HEATSINK
3
Power Dissipation [W]
4
Base Plate Temp [°C]
110
5°C/W
Base Plate Temp [°C]
2°C/W
10°C/W
5
Power Dissipation
18A
15