Miniature Power Relay G4A High switching capacity from normally open contact loop terminal construction ■ Miniature power relay ideal for motor switching in appliances and HVAC equipment ■ Designed specifically for high inrush compressor loads ■ Space-saving design ■ Semi-sealed construction, standard ■ Standard versions approved by UL, CSA, and VDE ■ Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G4A-1A-E-DC12). Type Standard Contact form SPST-NO Construction Semi-sealed Part number PCB and quick-connect G4A-1A-E PCB terminal G4A-1A-P-E Specifications ■ CONTACT DATA Load Rated load Contact material Max. carry current Max. operating voltage Max. operating current Max. switching capacity Min. permissible load Motor load Inrush 80 A (cosø 0.7) 0.35/20 A steady state (cosø 0.9) AgSnO2 20 A 250 VAC 20 A 5,000 VA 100 mA at 5 VDC ■ COIL DATA Rated voltage (VDC) Rated current (mA) Coil resistance (Ω) 12 24 75 37.50 160 640 Pick-up voltage Dropout voltage Maximum voltage % of rated voltage 70% max. Power consumption (W) 10% min. 110% Approx. 0.90 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10% for DC coil resistance. 2. Operating characteristics are measured at a coil temperature of 23°C (73°F). G4A G4A ■ CHARACTERISTICS Contact resistance Operate time Release time Maximum operating frequency Mechanical Electrical Insulation resistance Dielectric strength Vibration Mechanical durability Malfunction durability Shock Mechanical durability Malfunction durability Life expectancy Mechanical Electrical Ambient operating temperature Ambient operating humidity Weight 100 mΩ 20 ms max. 10 ms max. 18,000 operations/hour 1,200 operations/hour (under rated load) 1,000 MΩ min (at 500 VDC) 4,500 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range for 2 hours 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range for 5 minutes 1,000 m/s2 (approx. 100 G) 200 m/s2 (approx. 20 G) 2 million operations min. (at 18,000 operations/hour) 200,000 operations min. (at 1,200 operations/hour under rated) -25° to 60°C (-13° to 140°F) with no icing 35% to 85% 23 g (0.81 oz) Note: Data shown are of initial value. ■ CHARACTERISTIC DATA G4A-1A Switching current (A) Switching voltage (V) 2 Electrical service life Life expectancy (x103 operations) Maximum switching capacity Switching current (A) G4A G4A Dimensions Unit: mm (inch) ■ RELAYS G4A-1A-E Terminal arrangement/ Internal connections Tab terminals PCB terminals (Top view) (Bottom terminals) Mounting holes (Bottom view) G4A-1A-P-E Terminal arrangement/ Internal connections (Bottom view) Mounting holes (Bottom view) 3 G4A G4A ■ APPROVALS UL (File No. E41643)/CSA (File No. LR31928) Type G4A-1A-E G4A-1A-P-E Contact form SPST-NO Coil ratings 5 to 100 VDC Contact ratings Motor load 80 A, 250 VAC (make) 20 A, 250 VAC (break), 100,000 cycles Horsepower 1 HP, 120 VAC, 125 VAC, 240 VAC, 250 VAC, 277 VAC 2 HP, 240 VAC, 277 VAC, 30,000 cycles FLA/LRA 16 FLA, 96 LRA, 120 VAC, 30,000 cycles 12 FLA, 72 LRA, 150 VAC, 30,000 cycles 12 FLA, 72 LRA, 240 VAC, 30,000 cycles 23 A, 277 VAC, 30,000 cycles 15 A, 30 VDC 20 A, 250 VAC, 100,000 cycles 18 FLA, 90.5 LRA, 240 VAC, 100,000 cycles, 55°C (131°F) ambient 20 A, 120 VAC, 6,000 cycles 20 A, 277 VAC, 6,000 cycles General purpose Resistive Definite purpose Tungsten Ballast Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4. OMRON ELECTRONICS, INC. OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. GC RLY7 4 01/00 Specifications subject to change without notice. Printed in the U.S.A.