ETC G4A-1A-E

Miniature Power Relay
G4A
High switching capacity from normally
open contact loop terminal construction
■ Miniature power relay ideal for motor
switching in appliances and HVAC
equipment
■ Designed specifically for high inrush
compressor loads
■
Space-saving design
■ Semi-sealed construction, standard
■ Standard versions approved by UL,
CSA, and VDE
■
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G4A-1A-E-DC12).
Type
Standard
Contact form
SPST-NO
Construction
Semi-sealed
Part number
PCB and quick-connect
G4A-1A-E
PCB terminal
G4A-1A-P-E
Specifications
■ CONTACT DATA
Load
Rated load
Contact material
Max. carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
Motor load
Inrush 80 A (cosø 0.7) 0.35/20 A steady state (cosø 0.9)
AgSnO2
20 A
250 VAC
20 A
5,000 VA
100 mA at 5 VDC
■ COIL DATA
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
12
24
75
37.50
160
640
Pick-up
voltage
Dropout
voltage
Maximum
voltage
% of rated voltage
70% max.
Power
consumption
(W)
10% min.
110%
Approx. 0.90
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10% for DC coil
resistance.
2. Operating characteristics are measured at a coil temperature of 23°C (73°F).
G4A
G4A
■ CHARACTERISTICS
Contact resistance
Operate time
Release time
Maximum operating
frequency
Mechanical
Electrical
Insulation resistance
Dielectric strength
Vibration
Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Life expectancy
Mechanical
Electrical
Ambient operating temperature
Ambient operating humidity
Weight
100 mΩ
20 ms max.
10 ms max.
18,000 operations/hour
1,200 operations/hour (under rated load)
1,000 MΩ min (at 500 VDC)
4,500 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range for 2 hours
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude range for 5 minutes
1,000 m/s2 (approx. 100 G)
200 m/s2 (approx. 20 G)
2 million operations min. (at 18,000 operations/hour)
200,000 operations min. (at 1,200 operations/hour under rated)
-25° to 60°C (-13° to 140°F) with no icing
35% to 85%
23 g (0.81 oz)
Note: Data shown are of initial value.
■ CHARACTERISTIC DATA
G4A-1A
Switching current (A)
Switching voltage (V)
2
Electrical service life
Life expectancy (x103 operations)
Maximum switching capacity
Switching current (A)
G4A
G4A
Dimensions
Unit: mm (inch)
■ RELAYS
G4A-1A-E
Terminal arrangement/
Internal connections
Tab terminals
PCB terminals
(Top view)
(Bottom terminals)
Mounting holes
(Bottom view)
G4A-1A-P-E
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
3
G4A
G4A
■ APPROVALS
UL (File No. E41643)/CSA (File No. LR31928)
Type
G4A-1A-E
G4A-1A-P-E
Contact form
SPST-NO
Coil ratings
5 to 100 VDC
Contact ratings
Motor load
80 A, 250 VAC (make)
20 A, 250 VAC (break), 100,000 cycles
Horsepower
1 HP, 120 VAC, 125 VAC, 240 VAC, 250 VAC, 277 VAC
2 HP, 240 VAC, 277 VAC, 30,000 cycles
FLA/LRA
16 FLA, 96 LRA, 120 VAC, 30,000 cycles
12 FLA, 72 LRA, 150 VAC, 30,000 cycles
12 FLA, 72 LRA, 240 VAC, 30,000 cycles
23 A, 277 VAC, 30,000 cycles
15 A, 30 VDC
20 A, 250 VAC, 100,000 cycles
18 FLA, 90.5 LRA, 240 VAC,
100,000 cycles, 55°C (131°F) ambient
20 A, 120 VAC, 6,000 cycles
20 A, 277 VAC, 6,000 cycles
General purpose
Resistive
Definite purpose
Tungsten
Ballast
Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually
defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
4
01/00
Specifications subject to change without notice.
Printed in the U.S.A.