here to - American Zettler, Inc.

XMCK Series
Definite Purpose Contactors
Description
American Zettler XMCK series of Definite Purpose Contactors are electromecahnical switching devices designed ideally for the HVAC industry. The
most common applications of our contactors are found in refrigeration,
ARI conditioning, and heating. Other applications include elevators, food
service equipment, cranes, hoists, welding machines, power supplies,
vending machines, lighting, pumps and compressors. XMCK contactors
are built to the ARI 780/790 standard in our ISO 9001 manufacturing
facility for high performance and great reliabililty. XMCK is a affordable
solution with 1 to 2 pole configurations and ratings up to 50 amps.
Features
• A variety of termination options for specific application requirements
• Universal mounting plate: Easy replacement of competitor's contactors
• Convenient non-position sensitive mounting
• Performance unaffected by position mounting
• Dust-free internal construction
• UL, CUR file no. E222994
1/31/12
XMCK Series
PART NUMBERING SYSTEM
XMCK
-
50
D
024
C
-
XXX
Contact Ratings
Number of Poles
Coil Voltage
Terminal
Custom Special Code
Contact Ratings
30
25 FLA
40
30 FLA
50
40 FLA
Terminal with Quick Connects
Number of Poles
D
DN
2
1-pole
1-pole + 1 shunt
2-pole
A
B
Screw w/ quick connect
Sems clamp w/ quick connect
C
D
E
Slotted & Hex head washer w/ quick connect
Box Lug w/ quick connect
Box Lug w/ quick connect ( Line)
Slotted Hex head washer w/ quick connect (Load)
F
Slotted & Hex head washer w/ quick connect (Line)
Box Lug w/ quick connect (Load)
Coil Voltage
24
120
240
277
50Hz
24
110-120
208-240
---
60Hz
24
110-120
208-240
277
1/31/12
XMCK Series
Definite Purpose Contactors
General Data
Rated insulation voltage 690 Vrms
UL,CUR file E220475
Agency approvals
Vertical and Horizontal mounting recommended
Operating position
Ambient temperature
Weight
Torque
QC Wiring
-20°C to 70°C
-40°C to 70°C
1Pole - 210g, 2Pole - 290g
Screws 25 lb-in/Lugs 25 lb-in
The female connector should meet IEC 60760, necessary
to ensure the reliability of connection between female
connectors and QCterminals
Electrical
Rated Operating voltage
Switching frequency
Electrical endurance (ARI 780/790)
Mechanical endurance (ARI 780/790)
12V-600V max.
360 operations/hour
100,000 cycles
500,000 cycles
Electrical Ratings
Full Load Resistive
Locked Rotor Amps (LRA)
Amps
Load Amps
240/277V
480V
600V
(FLA)
(RLA)
25
32
40
30
40
50
Pole Form
150
125
100
150
125
-
150
75
50
180
150
-
240
160
100
240
150
-
1P
1P+1shunt
2P
1P
1P+1shunt
2P
1P
1P+1shunt
2P
Inrush
VA
Sealed
VA
Sealed
(W)
32
7.0
2.0-4.0
40
8.0
2.5-4.5
Order Number
XMCK- 30D
XMCK- 30DN
XMCK - 302
XMCK -40D
XMCK -40DN
XMCK - 402
XMCK - 50D
XMCK - 50DN
XMCK - 502
Coil Data
Pole Form
1 pole (D)
1 pole + 1 shunt (DN)
2 pole (2)
Pickup
Voltage
Dropout
Voltage
<¡Â0.8
0. 8Us*
Us
>
¡Ã0.2
0. 2Us*
Us
*Us = nominal coil voltage
1/31/12
XMCK Series
Definite Purpose Contactors
Note:
1. The locking torque for load circuit screw (M5) : 2.5N.m ~ 3.0 N.m.
2. If using terminal wiring, the harness should conform to IEC 60760 standard to insure safe wiring connection.
1 Pole/ 1Pole +1 Shunt (25-40FLA)
2 pole (25-40FLA)
1/31/12