48 Series - Relay Interface Modules 8 - 10 - 16 A 48.31 48.52 48.61 - 1 pole, 10 A - 35 mm rail (EN 50022) mounting - 2 pole, 8 A - 35 mm rail (EN 50022) mounting - 1 pole, 16 A - 35 mm rail (EN 50022) mounting - Relay interface modules for use with PLC systems, 15.5 mm wide - AC or sensitive DC coil versions available - Instant removal of relay using plastic retaining clip - Supply status indication or coil protection module provided - Identification label - 35 mm rail (EN 50022) mounting 75.3 60.9 17.5 17.5 COM 11 14 NO 12 NC 21 11 COM 21 11 COM 24 14 NO 24 14 NO 22 12 NC 22 12 NC A2 A1 COIL A2 A1 COIL 78.6 25.9 15.8 32 A2 A1 * for 400 V applications, requirements for pollution degree 2 are met. COIL Contact specifications Contact configuration Rated current/Maximum peak current A Rated voltage/Maximum switching voltage V AC Rated load in AC1 VA Rated load in AC15 (230 VAC) VA Single phase motor rating (230 VAC) kW/HP Breaking capacity in DC1: 30/110/220V Minimum switching load A mW (V/mA) Standard contact material 1 CO (SPDT) 2 CO (DPDT) 1 CO (SPDT) 10/20 8/15 16/30 250/400* 250/250 250/400* 2,500 2,000 4,000 500 400 750 0.37/0.6 0.3/0.4 0.55/0.8 10/0.3/0.12 8/0.3/0.12 16/0.3/0.12 300 (5/5) 300 (5/5) 500 (10/5) AgNi AgNi AgCdO 12 - 24 - 110 - 120 - 230 12 - 24 - 110 - 120 - 230 12 - 24 - 110 - 120 - 230 12 - 24 - 125 12 - 24 - 125 12 - 24 - 125 1.2/0.5 1.2/0.5 1.2/0.5 Coil specifications Nominal voltage (UN) V AC (50/60 Hz) V DC Rated power AC/sens. DC VA (50 Hz)/W Operating range AC (50 Hz) (0.8…1.1)UN (0.8…1.1)UN (0.8…1.1)UN DC/sens. DC (0.73…1.75)UN (0.73…1.75)UN (0.8…1.5)UN Holding voltage AC/DC 0.8 UN /0.4 UN 0.8 UN /0.4 UN 0.8 UN /0.4 UN Must drop-out voltage AC/DC 0.2 UN /0.1 UN 0.2 UN /0.1 UN 0.2 UN /0.1 UN Technical data Mechanical life AC/DC cycles 10 · 106/20 · 106 10 · 106/— 10 · 106/20 · 106 Electrical life at rated load AC1 cycles 200 · 103 150 · 103 100 · 103 10/10 - (15/12 sens.) 10/10 - (15/12 sens.) 10/10 - (15/12 sens.) Insulation according to EN 61810-5 3.6 kV/3 3.6 kV/3 3.6 kV/3 Insulation between coil and contacts (1.2/50µs) kV 6 (8mm) 6 (8mm) 6 (8mm) Operate/release time (bounce included) Dielectric strenght between open contacts Ambient temperature range Protection category Approvals (relay): (according to type) ms V AC °C 1,000 1,000 1,000 –40…+70 –40…+70 –40…+70 IP 20 IP 20 BEAB GOST IP 20 RINA ® C US 41 48 Series - Relay Interface Modules 8 - 10 - 16 A 48.62 - Relay interface modules for use with PLC systems, 15.5mm wide - AC or sensitive DC coil versions available - Instant removal of relay using plastic retaining clip - Supply status indication or coil protection module provided - Identification label - 35 mm rail (EN 50022) mounting - 2 pole, 10 A - 35 mm rail (EN 50022) mounting 75.3 60.9 17.5 17.5 21 11 COM 24 14 NO 22 12 NC A2 A1 COIL 78.6 25.9 15.8 32 * for 400 V applications requirements for pollution degree 2 are met. Contact specification Contact configuration 2 CO (DPDT) Rated current/Maximum peak current A 10/20 Rated voltage/Maximum switching voltage V AC Rated load in AC1 250/400* VA Rated load in AC15 (230 VAC) 2,500 VA Single phase motor rating (230 VAC) Breaking capacity in DC1: 30/110/220V Minimum switching load 500 kW/HP 0.37/0.6 A 10/0.3/0.12 mW (V/mA) 300 (5/5) Standard contact material AgNi Coil specifications Nominal voltage (UN) V AC (50/60 Hz) — V DC Rated power AC/sens. DC 12 - 24 - 125 VA (50 Hz)/W Operating range —/0.5 AC (50 Hz) — DC/sens. DC (0.8…1.7)UN Holding voltage AC/DC 0.8 UN /— Must drop-out voltage AC/DC 0.2 UN /— Mechanical life AC/DC cycles —/20 · 106 Electrical life at rated load AC1 cycles 100 · 103 Technical data Operate/release time (bounce included) ms 10/10 Insulation according to EN 61810-5 3.6 kV/3 Insulation between coil and contacts (1.2/50µs) kV 6 (8mm) Dielectric strenght between open contacts Ambient temperature range V AC 1,000 °C –40…+70 Protection category Approvals (relay): (according to type) 42 IP 20 ® C US GOST RINA 48 Series - Relay Interface Modules 8 - 10 - 16 A ORDERING INFORMATION Example: a 48 series 35 mm rail (EN 50022) mount relay interface module with 2 CO (DPDT) 6 A, coil rated 24 V sensitive DC, green LED + diode. A 4 8 . 5 2 . 7 . 0 2 4 . 0 Series Type 3 = 35 mm rail mount 5 = 35 mm rail mount 6 = 35 mm rail mount B C D 0 5 0 A: Contact material 0 = Standard D: Special applications 0 = Standard B: Contact circuit 0 = Standard C: Options 5 = Standard for DC: green LED + diode (polarity +A1) 6 = Standard for AC: green LED + Varistor No. of poles 1 = 1 CO (SPDT) for 48.31, 10 A 48.61, 16 A 2 = 2 CO (DPDT) for 48.52, 8 A 48.62, 10 A, DC only Coil version 7 = Sensitive DC 8 = AC (50/60 Hz) Coil voltage see coil specifications TECHNICAL DATA INSULATION INSULATION according to EN 61810-5 insulation rated voltage rated impulse withstand voltage V 250 kV 3.6 pollution degree 3 (48.31/61/62) overvoltage category III 2 (48.52) IMMUNITY CONDUCTED DISTURBANCE IMMUNITY BURST (according to EN 61000-4-4) level 4 (4kV) SURGE (according to EN 61000-4-5) level 3 (2kV) OTHER DATA VIBRATION RESISTANCE (10…55Hz): NO/NC POWER LOST IN THE ENVIRONMENT g/g without contact current W with rated current W 12 14 11 A1 1.2 (48.31) 1.3 (48.52) 12 14 22 24 12 14 22 24 11 11 21 11 21 +A1 –A2 DC Type 48.31 3/3 (2 CO) 12 14 A2 AC 10/4 (1 CO) 0.7 A1 A2 1.2 (48.61) (22) 12 14 (24) AC Type 48.52 Type 48.62 11 (21) A2 +A1 –A2 DC (22) 12 14 (24) 11 (21) A1 +A1 1.2 (48.62) –A2 DC AC Type 48.61 43 48 Series - Relay Interface Modules 8 - 10 - 16 A CONTACT SPECIFICATIONS 10 7 10 6 10 5 F 48/2 CYCLES CYCLES F 48/1 1 0 2 8 4 12 10 7 10 6 10 5 16 H 48/2 1 2 3 10 6 4 2 B A 1 0.2 0.1 60 100 140 180 220 DC VOLTAGE (V) Breaking capacity for DC1 load. 1 - Type 48.61. 2 - Type 48.31. 3 - Type 48.52. A - Load applied to 1 contact B - Load applied to 2 contacts in series • When switching a resistive load (DC1) having voltage and current values under the curve the expected electrical life is ≥ 100·103 cycles. • In case of DC13 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC1 load. Note: the release time of load will be increase. DC BREAKING CURRENT (A) H 48/1 DC BREAKING CURRENT (A) Electrical life vs AC1 load. Type 48.62 (10 A). 20 12 16 LOAD RATED CURRENT (A) Electrical life vs AC1 load. 1 - Type 48.52 (8 A). 2 - Type 48.31 (10 A). Type 48.61 (16 A). 20 44 8 4 0 LOAD RATED CURRENT (A) 20 10 6 4 2 B A 1 0.2 0.1 20 60 100 140 180 220 DC VOLTAGE (V) Breaking capacity for DC1 load. 1 - Type 48.62. A - Load applied to 1 contact B - Load applied to 2 contacts in series • When switching a resistive load (DC1) having voltage and current values under the curve the expected electrical life is ≥ 100·103 cycles. • In case of DC13 loads the connection of a diode in parallel with the load will permit the same electrical life as for a DC1 load. Note: the release time of load will be increase. 48 Series - Relay Interface Modules 8 - 10 - 16 A COIL SPECIFICATIONS DC VERSION DATA (0.5 W sensitive) AC VERSION DATA Nominal voltage UN V 12 24 110 120 230 Coil code Operating range Umin V 9.6 19.2 88 96 184 8.012 8.024 8.110 8.120 8.230 Umax V 13.2 26.4 121 132 253 Rated coil absorption I at UN (50Hz) mA 90.5 46 10.1 11.8 60.2 Nominal voltage UN V 12 24 125 Coil code Umin* V 8.8 17.5 92 7.012 7.024 7.152 Umax V 21 42 218 Rated coil absorption I at UN mA 41 22.2 4 *Umin = 0.8 UN for 48.61 and 48.62 R 48 sens. DC R 48 AC U 2.0 UN U 2.0 UN 1.5 Operating range 1.5 1 1 1.0 1.0 48.61/62 48.31/52 2 2 0.5 0.5 -20 0 20 40 60 80 -20 0 AMBIENT TEMPERATURE (°C) Operating range (sensitive DC version) vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature 20 40 60 80 AMBIENT TEMPERATURE (°C) Operating range (AC version) vs ambient temperature. 1 - Max coil voltage permitted 2 - Min pick-up voltage with coil at ambient temperature ACCESSORIES 8-way jumper link for 48 series 095.18 15 15.8 15.8 15.8 15.8 15.8 15 10.3 - RATED VALUES: 10 A - 250 V 5.1 7 095.18 3.3 110.5 45