ETC 6CWQ04F

PD-2.313 rev. A 12/97
6CWQ03F
6CWQ04F
SCHOTTKY RECTIFIER
6.6 Amp
Major Ratings and Characteristics
Description/Features
Characteristics
6CWQ..F
Units
I F(AV) Rectangular
6.6
A
30/40
V
I FSM @ tp = 5 µs sine
470
A
VF
0.55
V
- 40 to 125
°C
waveform
VRRM
@ 3 Apk, TJ = 25°C
(per leg)
TJ
The 6CWQ..F surface mount, center tap, Schottky rectifier
has been designed for applications requiring low forward drop
and small foot prints on PC boards. Typical applications are
in disk drives, switching power supplies, converters, freewheeling diodes, battery charging, and reverse battery
protection.
Popular D-PAK outline
Center tap configuration
Small foot print, surface mountable
Low forward voltage drop
High frequency operation
Guard ring for enhanced ruggedness and long term
reliability
CASE STYLE AND DIMENSIONS
D - PAK Outline (Similar to TO-252AA)
Dimensions in millimeters and inches
www.irf.com
1
6CWQ03F, 6CWQ04F
PD-2.313 rev. A 12/97
Voltage Ratings
Part number
VR
Max. DC Reverse Voltage (V)
VRWM Max. Working Peak Reverse Voltage (V)
6CWQ03F
6CWQ04F
30
40
Absolute Maximum Ratings
Parameters
6CWQ..F Units
IF(AV) Max. Average Forward Current
6.6
A
Conditions
50% duty cycle @ TC = 97 °C, rectangular wave form
* See Fig. 5
IFSM
Max. Peak One Cycle Non-Repetitive
470
Surge Current (Per Leg) * See Fig. 7
42
A
5µs Sine or 3µs Rect. pulse
10ms Sine or 6ms Rect. pulse
Following any rated
load condition and with
rated V RRMapplied
Electrical Specifications
Parameters
VFM
IRM
6CWQ..F Units
Max. Forward Voltage Drop
(Per Leg) * See Fig. 1
(1)
Conditions
0.55
0.71
0.50
V
V
V
@ 3A
@ 6A
@ 3A
0.63
V
@ 6A
Max. Reverse Leakage Current
3
mA
TJ = 25 °C
(Per Leg) * See Fig. 2
20
mA
TJ = 125 °C
(1)
T J = 25 °C
TJ = 125 °C
VR = rated VR
CT
Typical Junction Capacitance (Per Leg)
180
pF
VR = 5VDC , (test signal range 100Khz to 1Mhz) 25°C
LS
Typical Series Inductance (Per Leg)
5.0
nH
Measured lead to lead 5mm from package body
10,000
V/ µs
dv/dt Max. Voltage Rate of Change
(Rated VR)
(1) Pulse Width < 300µs, Duty Cycle <2%
Thermal-Mechanical Specifications
Parameters
6CWQ..F Units
TJ
Max. Junction Temperature Range
-40 to 125
°C
Tstg
Max. Storage Temperature Range
-40 to 125
°C
RthJC Max. Thermal Resistance Junction
to Case
5.0
°C/W DCoperation
RthJA Max. Thermal Resistance Junction
to Ambient
80
°C/W DCoperation
PC Board mounted print land = 20x20mm
wt
Approximate Weight
Case Style
2
Conditions
0.3 (0.01)
* See Fig. 4
g (oz.)
D - PAK
Similar to TO-252AA
www.irf.com
6CWQ03F, 6CWQ04F
PD-2.313 rev. A 12/97
100
ReverseCurrent - I (mA)
R
10
10
T =125°C
J
1
100°C
75°C
.1
50°C
.01
25°C
.001
.0001
0
5
10
15
20
25
30
35
40
ReverseVoltage - VR(V)
Fig. 2 - Typical Values Of Reverse Current
Vs. Reverse Voltage (Per Leg)
T =125°C
J
T = 25°C
J
1000
JunctionCapacitance- C (pF)
T
Instantaneous ForwardCurrent - I (A)
F
100
1
.1
.1 .2 .3 .4 .5 .6 .7 .8 .9
T =25°C
J
100
10
0
1 1.1 1.2 1.3
5
10 15 20 25 30 35 40 45
ForwardVoltage Drop - V (V)
FM
ReverseVoltage- VR(V)
Fig. 3 - Typical Junction Capacitance
Vs. Reverse Voltage (Per Leg)
Fig. 1 - Max. Forward Voltage Drop Characteristics
(PerLeg)
Thermal Impedance- Z
(°C/W
)
thJC
10
D=0.50
1
D=0.33
D=0.25
P
DM
D=0.17
t
1
t2
D=0.08
.1
Notes:
1. Dutyfactor D= t1/ t2
Single Pulse
(Thermal Resistance)
.01
.00001
.0001
.001
.01
2. PeakT =P x Z
+T
J DM thJC C
.1
1
10
100
t1, Rectangular Pulse Duration(Seconds)
Fig. 4 - Max. Thermal Impedance ZthJC Characteristics (Per Leg)
www.irf.com
3
6CWQ03F, 6CWQ04F
PD-2.313 rev. A 12/97
3
RthJC(DC) =5.0°C/W
Average Power Loss- (Watts)
AllowableCaseTemperature -(°C)
130
125
120
DC
115
110
0
1
2
3
4
D=0.08
D=0.17
D=0.25
D=0.33
2 D=0.50
2.5
DC
1.5
RMSLimit
1
.5
0
0 .5 1 1.5 2 2.5 3 3.5 4 4.5 5
5
AverageForwardCurrent - I
AverageForwardCurrent - IF(AV) (A)
Fig. 5 - Max. Allowable Case Temperature
Vs. Average Forward Current (Per Leg)
F(AV)
(A)
Fig. 6 - Forward Power Loss Characteristics
(PerLeg)
Non-Repetitive Surge Current - I
FSM
(A)
1000
100
At Any Rated Load Condition
And With Rated V
Applied
RRM
Following Surge
10
10
100
1000
10000
Square Wave Pulse Duration - t p (microsec)
Fig. 7 - Max. Non-Repetitive Surge Current (Per Leg)
4
www.irf.com