AD ADXL345

Three-Axis, ±2/4/8/16g
Digital Accelerometer
ADXL345
Preliminary Technical Data
FEATURES
GENERAL DESCRIPTION
Ultra low power: 25 to 130 µA at VS = 2.5 V (typ)
Power consumption scales automatically with bandwidth
User selectable fixed 10-bit resolution or 4mg/LSB scale
factor in all g-ranges, up to 13-bit resolution at ±16 g
32 level output data FIFO minimizes host processor load
Built in motion detection functions
•
Tap/Double Tap detection
•
Activity/Inactivity monitoring
•
Free-Fall detection
Supply and I/O voltage range: 1.8 V to 3.6 V
SPI (3 and 4 wire) and I2C digital interfaces
Flexible interrupt modes – Any interrupt mappable to either
interrupt pin
Measurement ranges selectable via serial command
Bandwidth selectable via serial command
Wide temperature range (-40 to +85°C)
10,000 g shock survival
Pb free/RoHS compliant
Small and thin: 3 × 5 × 1 mm LGA package
The ADXL345 is a small, thin, low power, three-axis
accelerometer with high resolution (13-bit) measurement up to
±16 g. Digital output data is formatted as 16-bit twos
complement and is accessible through either a SPI (3- or 4wire) or I2C digital interface.
The ADXL345 is well suited for mobile device applications. It
measures the static acceleration of gravity in tilt-sensing
applications, as well as dynamic acceleration resulting from
motion or shock. Its high resolution (4mg/LSB) enables
resolution of inclination changes of as little as 0.25°.
Several special sensing functions are provided. Activity and
inactivity sensing detect the presence or lack of motion and if
the acceleration on any axis exceeds a user-set level. Tap sensing
detects single and double taps. Free-Fall sensing detects if the
device is falling. These functions can be mapped to interrupt
output pins. An integrated 32 level FIFO can be used to store
data to minimize host processor intervention.
Low power modes enable intelligent motion-based power
management with threshold sensing and active acceleration
measurement at extremely low power dissipation.
APPLICATIONS
Handsets
Gaming and pointing devices
Personal navigation devices
HDD protection
Fitness equipment
Digital cameras
The ADXL345 is supplied in a small, thin 3 mm × 5 mm ×
1 mm, 14-lead, plastic package.
FUNCTIONAL BLOCK DIAGRAM
Vs
VDD I/O
POWER
MANAGEMENT
A/D
CONVERTER
3 AXIS
SENSOR
SENSE
ELECTRONICS
DIGITAL
FILTER
CONTROL
AND
INTERRUPT
LOGIC
INT1
INT2
SDA/SDI/SDIO
SERIAL I/O
ADXL345
SDO/ALT
ADDRESS
SCL/SCLK
COM
CS
Figure 1. ADXL345 Simplified Block Diagram
Rev. PrA
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2008 Analog Devices, Inc. All rights reserved.
ADXL345
Preliminary Technical Data
TABLE OF CONTENTS
Features .............................................................................................. 1
I2C................................................................................................. 10
Applications....................................................................................... 1
Interrupts..................................................................................... 11
General Description ......................................................................... 1
FIFO ............................................................................................. 11
Functional Block Diagram .............................................................. 1
Self Test ........................................................................................ 12
Revision History ............................................................................... 2
Register Map ................................................................................... 13
Specifications..................................................................................... 3
Register Definitions ................................................................... 14
Absolute Maximum Ratings............................................................ 4
Application ...................................................................................... 18
ESD Caution.................................................................................. 4
Power Supply Decoupling ......................................................... 18
Pin Configuration and Descriptions.............................................. 5
Mechanical Considerations for Mounting.............................. 18
Typical performance characteristics .............................................. 6
Tap Detection.............................................................................. 18
Functional Description .................................................................... 7
Threshold .................................................................................... 19
Device Operation ......................................................................... 7
Link Mode ................................................................................... 19
Power Sequencing ........................................................................ 7
Recommended PWB Land Pattern.......................................... 20
Power Saving ................................................................................. 7
Recommended Soldering Profile ............................................. 21
Serial Communications ................................................................... 9
Outline Dimensions ....................................................................... 22
SPI................................................................................................... 9
Ordering Guide .......................................................................... 22
REVISION HISTORY
11/08—Rev. PrA - Initial Version
Rev. PrA | Page 2 of 24
Preliminary Technical Data
ADXL345
SPECIFICATIONS
TA = 25°C, VS = 2.5 V, VDD I/O = 1.8 V, Acceleration = 0 g, unless otherwise noted.
Table 1. Specifications1
Parameter
SENSOR INPUT
Measurement Range
Nonlinearity
Inter-Axis Alignment Error
Cross-Axis Sensitivity2
OUTPUT RESOLUTION
All g-ranges
±2 g range
±4 g range
±8 g range
±16 g range
SENSITIVITY
Sensitivity at XOUT, YOUT, ZOUT
Scale Factor at XOUT, YOUT, ZOUT
Sensitivity at XOUT, YOUT, ZOUT
Scale Factor at XOUT, YOUT, ZOUT
Sensitivity at XOUT, YOUT, ZOUT
Scale Factor at XOUT, YOUT, ZOUT
Sensitivity at XOUT, YOUT, ZOUT
Scale Factor at XOUT, YOUT, ZOUT
Sensitivity Change due to Temperature
0 g BIAS LEVEL
0 g Output (XOUT, YOUT, ZOUT)
0 g Offset vs. Temperature
NOISE PERFORMANCE
Noise (x-, y-axes)
Noise (z-axis)
OUTPUT DATA RATE / BANDWIDTH
Measurement Rate3
SELF TEST
Output Change X
Output Change Y
Output Change Z
POWER SUPPLY
Operating Voltage Range (VS)
Interface Voltage Range (VDD I/O)
Supply Current
Supply Current
Standby Mode Leakage Current
Turn-On Time4
TEMPERATURE
Operating Temperature Range
WEIGHT
Device Weight
Conditions
Each axis
User Selectable
Percentage of full scale
Min
Typ
Max
Unit
±2, 4, 8, 16
±0.5
±0.1
±1
g
%
Degrees
%
10
10
11
12
13
Bits
Bits
Bits
Bits
Bits
Each axis
10-bit mode
Full-Resolution
Full-Resolution
Full-Resolution
Full-Resolution
Each axis
VS = 2.5 V, ±2 g 10-bit or Full-Resolution
VS = 2.5 V, ±2 g 10-bit or Full-Resolution
VS = 2.5 V, ±4 g 10-bit mode
VS = 2.5 V, ±4 g 10-bit mode
VS = 2.5 V, ±8 g 10-bit mode
VS = 2.5 V, ±8 g 10-bit mode
VS = 2.5 V, ±16 g 10-bit mode
VS = 2.5 V, ±16 g 10-bit mode
232
3.5
116
7.0
58
14.0
29
28.1
256
3.9
128
7.8
64
15.6
32
31.2
±0.02
286
4.3
143
8.6
71
17.2
36
34.3
LSB/g
mg/LSB
LSB/g
mg/LSB
LSB/g
mg/LSB
LSB/g
mg/LSB
%/°C
Each axis
VS = 2.5 V, TA = 25°C
-150
0
<±1
+150
mg
mg/°C
Data Rate = 100 Hz, ±2 g 10-bit or Full-Res.
Data Rate = 100 Hz, ±2 g 10-bit or Full-Res.
User Selectable
<1
<1.5
0.1
3200
Hz
+0.31
-0.31
+0.46
+1.02
-1.02
+1.64
g
g
g
3.6
VS
150
V
V
µA
µA
µA
ms
2.0
1.7
Data Rate > 100 Hz
Data Rate < 10 Hz
Data Rate = 3200 Hz
2.5
1.8
130
25
0.1
1.4
−40
2
85
20
1
LSB RMS
LSB RMS
°C
mgrams
All minimum and maximum specifications are guaranteed. Typical specifications are not guaranteed.
Cross-axis sensitivity is defined as coupling between any two axes.
3
Bandwidth is half the output data rate.
4
Turn-on and wake-up times are determined by the user defined bandwidth. At 100 Hz data rate the turn-on/wake-up time is approximately 11.1 ms. For additional
data rates the turn-on/wake-up time is approximately τ + 1.1 in milliseconds, where τ is 1/(Data Rate).
2
Rev. PrA | Page 3 of 24
ADXL345
Preliminary Technical Data
ABSOLUTE MAXIMUM RATINGS
Table 2. Absolute Maximum Ratings
Parameter
Acceleration (Any Axis, Unpowered)
Acceleration (Any Axis, Powered)
VS
VDD I/O
All Other Pins
Output Short-Circuit Duration
(Any Pin to Ground)
Temperature Range (Powered)
Temperature Range (Storage)
Rating
10,000 g
10,000 g
−0.3 V to 3.6 V
−0.3 V to 3.6
−0.3 V to 3.6
Indefinite
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
−40°C to +105°C
−40°C to +105°C
ESD CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily accumulate on
the human body and test equipment and can discharge without detection. Although this product features
proprietary ESD protection circuitry, permanent damage may occur on devices subjected to high energy
electrostatic discharges. Therefore, proper ESD precautions are recommended to avoid performance
degradation or loss of functionality.
Rev. PrA | Page 4 of 24
Preliminary Technical Data
ADXL345
PIN CONFIGURATION AND DESCRIPTIONS
SDO/ALT ADDRESS
Figure 2. Pin Configuration (Top View)
Table 3. Pin Descriptions
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Mnemonic
VDD I/O
GND
Reserved
GND
GND
VS
CS
INT1
INT2
GND
Reserved
SDO/ALT ADDRESS
SDA/SDI/SDIO
SCL/SCLK
Description
Digital Interface Supply Voltage
Must be connected to ground
Reserved, must be connected to VS or left open
Must be connected to ground
Must be connected to ground
Supply Voltage
Chip Select
Interrupt 1 Output
Interrupt 2 Output
Must be connected to ground
Reserved, must be connected to GND or left open
Serial Data Out, Alternate I2C Address Select
Serial Data (I2C), Serial Data In (SPI 4-Wire), Serial Data In/Out (SPI 3-Wire)
Serial Communications Clock
Rev. PrA | Page 5 of 24
ADXL345
Preliminary Technical Data
TYPICAL PERFORMANCE CHARACTERISTICS
Rev. PrA | Page 6 of 24
Preliminary Technical Data
ADXL345
FUNCTIONAL DESCRIPTION
DEVICE OPERATION
The ADXL345 is a complete three-axis acceleration
measurement system with a selectable measurement range of
either ±2 g, ±4 g, ±8 g, or ±16 g. It measures both dynamic
acceleration resulting from motion or shock and static
acceleration, such as gravity, which allows it to be used as a tilt
sensor. The sensor is a polysilicon surface-micromachined
structure built on top of a silicon wafer. Polysilicon springs
suspend the structure over the surface of the wafer and provide
a resistance against acceleration forces. Deflection of the
structure is measured using differential capacitors that consist
of independent fixed plates and plates attached to the moving
mass. Acceleration deflects the beam and unbalances the
differential capacitor, resulting in a sensor output whose
amplitude is proportional to acceleration. Phase-sensitive
demodulation is used to determine the magnitude and polarity
of the acceleration.
POWER SEQUENCING
Power may be applied to VS or VDD I/O in any sequence without
damaging the ADXL345. All possible power on states are
summarized in Table 4. The interface voltage level is set with
the interface supply voltage VDD I/O, which must be present to
ensure that the ADXL345 does not create a conflict on the
communications bus. For single-supply operation, VDD I/O can be
the same as the main supply, VS. Conversely, in a dual-supply
application, VDD I/O can differ from VS to accommodate the
desired interface voltage. Once VS is applied, the device enters
standby state, where power consumption is minimized and the
device waits for VDD I/O to be applied and a command to enter
measurement state (setting the MEASURE bit in the
POWER_CTL register). Clearing the MEASURE bit returns the
device to standby state.
Table 4. Power Sequencing
Condition
Power Off
Bus Enabled
VS VDD I/O Description
Completely off, potential for
Off Off
communications bus conflict.
No functions available, but will not create
Off On
conflict on communications bus.
Standby or
On
Measurement
On
At power up the device is in Standby mode
awaiting a command to enter measurement
mode and all sensor functions are off. Once
instructed to enter Measurement mode, all
sensor functions are available.
POWER SAVING
Power Modes
The ADXL345 automatically modulates its power consumption
proportionally with its output data rate as shown in Table 5. If
additional power savings is desired, a lower power mode is
available. In this mode, the internal sampling rate is reduced
allowing for power savings in the 12.5 to 400Hz data rate range
at the expense of slightly greater noise. To enter lower power
mode, set the LOW_POWER bit(D4) in the BW_RATE
register.
Table 5. Current Consumption versus Data Rate
Output Data Bandwidth Rate Code
Rate (Hz)
(Hz)
3200
1600
1111
1600
800
1110
800
400
1101
400
200
1100
200
100
1011
100
50
1010
50
25
1001
25
12.5
1000
12.5
6.25
0111
6.25
3.125
0110
3.125
1.563
0101
1.563
0.782
0100
0.782
0.39
0011
0.39
0.195
0010
0.195
0.098
0001
0.098
0.048
0000
IDD (µA)
130
80
130
130
130
130
80
55
37
25
25
25
25
25
25
25
The current consumption in Low Power Mode is shown in
Table 6. Cases where there is no advantage to using Low Power
Mode are shaded.
Table 6. Current Consumption versus Data Rate in Low
Power Mode
Output Bandwidth Rate Code
Data Rate
(Hz)
3200
1600
1111
1600
800
1110
800
400
1101
400
200
1100
200
100
1011
100
50
1010
50
25
1001
25
12.5
1000
12.5
6.25
0111
6.25
3.125
0110
3.125
1.563
0101
1.563
0.782
0100
0.782
0.39
0011
0.39
0.195
0010
0.195
0.098
0001
0.098
0.048
0000
Rev. PrA | Page 7 of 24
IDD (µA)
130
80
130
80
55
37
30
25
25
25
25
25
25
25
25
25
ADXL345
Preliminary Technical Data
Auto Sleep Mode
Additional power can be saved by having the ADXL345
automatically switch to sleep mode during periods of inactivity.
To enable this feature set the THRESH_INACT register to an
acceleration value that signifies no activity (this value will
depend on the application), set TIME_INACT to an
appropriate inactivity time period (again, this will depend on
the application), and set the AUTO_SLEEP bit and the LINK bit
in the POWER_CTL register. Current consumption at the sub8Hz data rates used in this mode is typically 25 µA.
Standby Mode
For even lower power operation Standby Mode can be used. In
Standby Mode current consumption is reduced to 2µA (typical).
In this mode no measurements are made and communication
with the ADXL345 is limited to single-byte read or writes.
Standby Mode is entered by clearing the MEASURE bit (D3) in
the POWER_CTL register. Placing the device into Standby
Mode will preserve the contents of the FIFO.
Rev. PrA | Page 8 of 24
Preliminary Technical Data
ADXL345
SERIAL COMMUNICATIONS
ADXL345
I C and SPI digital communications are available. In both cases,
the ADXL345 operates as a slave. I2C mode is enabled if the CS
pin is tied high to VDD I/O. In SPI mode, the CS pin is controlled
by the bus master. In both SPI and I2C modes of operation, data
transmitted from the ADXL345 to the master device should be
ignored during writes to the ADXL345.
SCL/SCLK
high at the end as shown in Figure 5. SCLK is the serial port
clock and is supplied by the SPI master. It is stopped high when
CS is high, during period of no transmission. SDI and SDO are
the serial data in and out respectively. Data should be sampled
at the rising edge of SCLK.
To read or write multiple bytes in a single transmission, the
Multi-Byte bit, located after the R/W bit in the first byte
transfer, must be set. After the register addressing and the first
byte of data, continued clock pulses will cause the ADXL345 to
point to the next register for read or write. Continued clock
pulses will continue to shift the register that is pointed to until
the clock pulses are ceased and CS is de-asserted. To perform
reads or writes on different, non-sequential registers, CS must
be de-asserted between transmissions and the new register must
be addressed separately.
D OUT
D IN/OUT
SDO
D IN
SCL/SCLK
D OUT
Figure 3. 4-Wire SPI connection
The timing diagram for 3-wire SPI reads or writes is shown in
Figure 5. The 4-wire equivalents for SPI reads and writes are
shown in Figure 6 and Figure 7 respectively.
CS is the serial port enable line, and is controlled by the SPI
master. It must go low at the start of transmissions and back
tDELAY
D OUT
Figure 4. 3-Wire SPI connection
PROCESSOR
SDA/SDI/SDIO
D IN/OUT
SDO
For SPI, either 3-wire or 4-wire configuration is possible, as
shown in the connection diagrams in Figure 3 and Figure 4.
Clearing the SPI bit in the DATA_FORMAT register selects 4-wire
mode while setting the SPI bit selects 3-wire mode. The maximum
SPI clock speed is 5 MHz, with 12 pF maximum loading and
the timing scheme follows CPOL = 1, CPHA = 1.
CS
D OUT
SDA/SDI/SDIO
SPI
ADXL345
PROCESSOR
CS
2
tSCLK
tS
tM
tQUIET
CS
SCLK
SDI
R/W
MB
A[5]
A[4]
A[3]
A[2]
A[1]
A[0]
D[7] D[6]
D[5] D[4] D[3] D[2]
D[1] D[0]
SDO
tSETUP
tHOLD
tSDO
Figure 5. SPI 3-wire Timing Diagram
tDELAY
tSCLK
tS
tM
tQUIET
CS
SCLK
SDI
R/W
MB
A[5]
A[4]
SDO
A[3]
A[2]
A[1]
A[0]
D[7] D[6]
D[5] D[4]
tSETUP
tHOLD
tSDO
Figure 6. SPI 4-wire Read Timing Diagram
Rev. PrA | Page 9 of 24
D[3] D[2]
D[1] D[0]
ADXL345
Preliminary Technical Data
tDELAY
tSCLK
tS
tM
tQUIET
CS
SCLK
SDI
R/W
MB
A[5]
A[4]
A[3]
A[2]
A[1]
A[0]
D[7] D[6]
D[5] D[4]
D[3] D[2]
D[1] D[0]
SDO
tSETUP
tHOLD
tSDO
Figure 7. SPI 4-wire Write Timing Diagram
Table 7. SPI Timing Specifications
(TA = 25°C, VS = 2.5V, VDD I/O = 1.8V)
for the device is 0x1D, followed by the read/write bit. This
translates to 0x3A for write, 0x3B for read. An alternate I2C
address of 0x53 (followed by the read/write bit) may be chosen
by grounding the SDO pin (pin 12). This translates to 0xA6 for
write, 0xA7 for read.
Parameter Limit
fSCLK
tSCLK
tDELAY
tQUIET
tS
tM
tSDO
tSETUP
tHOLD
Unit
Description
5 MHz max SPI clock frequency
1/(SPI clock frequency) Mark/space
200 ns min
ratio for the SCLK input is 40/60 to
60/40
200 ns min
falling edge to SCLK falling edge
200 ns min
SCLK rising edge to rising edge
0.4 × tSCLK ns min
SCLK low pulse width (space)
0.4 × tSCLK ns min
SCLK high pulse width (mark)
8 ns max
SCLK falling edge to SDO transition
10 ns min
SDI valid before SCLK rising edge
10 ns min
SDI valid after SCLK rising edge
VDD I/O
ADXL345
RP
RP
PROCESSOR
CS
SDA/SDI/SDIO
D IN/OUT
SDO
SCL/SCLK
D OUT
06238- 007
I2C
Figure 8. I2C Connection Diagram (Address = 0x53)
With CS tied high to VDD I/O, the ADXL345 is in I2C mode,
requiring a simple 2-wire connection as shown in Figure 8. The
ADXL345 conforms to The I2C Bus Specification, Version 2.1,
January 2000, available from Phillips Semiconductor. It
supports standard (100 kHz) and fast (400 kHz) data transfer
modes. Single or multiple byte read/writes are supported as
shown in Figure 9. With the SDO pin high the 7 bit I2C address
Single Byte Write
Master
Start
Slave Address + Write
Slave
Ack
Multi-Byte Write
Master
Start
Slave Address + Write
Slave
Ack
Single Byte Read
Master
Start
Slave Address + Write
Slave
Ack
Multi-Byte Read
Master
Start
Slave Address + Write
Slave
Ack
1
This Start is either a restart or a Stop followed by a Start
If other devices are connected to the same I2C bus, the nominal
operating voltage level of these other devices cannot exceed
VDD I/O by more than 0.3 V. Pull-up resistors, RP, should be in the
range of 1k to 20kΩ.
Data
Register Address
Ack
Stop
Ack
Data
Register Address
Ack
Start1
Register Address
Data
Start1
Ack
Slave Address + Read
Ack
Register Address
Stop
Ack
NAck
Ack
Data
Ack
Data
Slave Address + Read
Ack
Figure 9. I2C Timing Diagram
Rev. PrA | Page 10 of 24
Stop
Ack
NAck
Data
Stop
Preliminary Technical Data
ADXL345
INTERRUPTS
OVERRUN
The ADXL345 provides two output pins for driving interrupts:
INT1 and INT2. Each of the interrupt functions are described
in detail below. All functions can be used simultaneously, with
the only limiting feature being that some functions may need to
share interrupt pins. Interrupts are enabled by setting the
appropriate bit in the INT_ENABLE register and are mapped to
either the INT1 or INT2 pins based on the contents of the
INT_MAP register. It is recommended that interrupts be
configured with the interrupts disabled, preventing interrupts
from being accidentally triggered during configuration. This
can be done by writing a value of 0x00 to the INT_ENABLE
register.
OVERRUN is set when new data has replaced unread data. The
precise operation of OVERRUN depends on the FIFO mode.
In Bypass Mode, OVERRUN is set when new data replaces
unread data in the DATAX, DATAY, and DATAZ registers. In
all other modes, OVERRUN is set when the FIFO is filled.
OVERRUN is cleared by reading the FIFO contents, and is
automatically cleared when the data is read.
DATA_READY
DATA_READY is set when new data is available and cleared
when no new data is available.
SINGLE_TAP
FIFO
The ADXL345 contains a 32 level FIFO that can be used to
minimize host processor intervention. The FIFO has four
modes as described in Table 15 in the Register Definitions
section. Mode selection is made by setting the appropriate
MODE bits in the FIFO_CTL register. Each FIFO mode is
described below.
Bypass Mode
SINGLE_TAP is set when single acceleration event that is
greater than the value in the THRESH_TAP register occurs for
a time shorter than specified in the DUR register.
DOUBLE_TAP
DOUBLE_TAP is set when two acceleration events that are
greater than the value in the THRESH_TAP register occur that
are shorter than the time specified in the DUR register, with the
second tap starting after the time specified by the LATENT
register and within the time specified in the WINDOW
register. See the Tap Detection description in the Application
section for more details.
ACTIVITY
ACTIVITY is set when acceleration greater than the value
stored in THRESH_ACT is experienced.
In Bypass Mode the FIFO is not operational and remains empty.
FIFO Mode
In FIFO Mode data from X, Y, and Z measurements go into the
FIFO. When the FIFO is filled to the level specified in
SAMPLES (in the FIFO_CTL register), the WATERMARK
interrupt is set. The FIFO will continue filling until it is full (32
X, Y, and Z samples) and then stop collecting data. After the
FIFO has stopped collecting data the device still continues to
operate, so features like Tap detection, for example, may still be
used once the FIFO is full. The WATERMARK interrupt will
continue to occur until the number of samples in the FIFO is
less than the value of SAMPLES in the FIFO_CTL register.
Stream Mode
INACTIVITY
INACTIVITY is set when acceleration of less than the value
stored in the THRESH_INACT register is experienced for
longer than the time specified in the TIME_INACT register.
The maximum value for TIME_INACT is 255 s.
FREE_FALL
FREE_FALL is set when acceleration of less than the value
stored in the THRESH_FF register is experienced for longer
than the time specified in the TIME_FF register. The
FREE_FALL interrupt differs from INACTIVITY interrupt in
that all axes always participate, the timer period is much smaller
(1.28 s maximum) and it is always DC coupled.
WATERMARK
WATERMARK is set when the FIFO has filled up to the value
stored in SAMPLES. It is cleared automatically when the FIFO
is read and its content emptied below the value stored in
SAMPLES.
In Stream Mode data from X, Y, and Z measurements go into
the FIFO. When the FIFO is filled to the level specified in
SAMPLES (in the FIFO_CTL register), the WATERMARK
interrupt is set. The FIFO will continue filling, and will hold
the latest 32 X, Y, and Z samples, discarding older data as new
data arrives. The WATERMARK interrupt will continue to
occur until the number of samples in the FIFO is less than the
value of SAMPLES in the FIFO_CTL register.
Trigger Mode
In Trigger Mode, the FIFO fills and holds the latest 32 X, Y, and
Z samples. Once a trigger event occurs (as described by the
TRIG_SOURCE bit in the FIFO_CTL register), the FIFO will
keep the last n samples (where n is the value specified by
SAMPLES in the FIFO_CTL register) and then operate in FIFO
mode, collecting new samples only when the FIFO is not full.
Additional trigger events will not be recognized until Trigger
Mode is reset. This can be done by setting the device in Bypass
Mode, reading the FIFO_STATUS register and then setting the
device back into Trigger Mode. The FIFO data should be read
first, as placing the device into Bypass Mode will clear the FIFO.
Rev. PrA | Page 11 of 24
ADXL345
Preliminary Technical Data
Retrieving Data from the FIFO
Table 9. Self Test output in LSB for 4 g 10-bit
FIFO data is read through the DATAX, DATAY and DATAZ
registers. When the FIFO is in FIFO, Stream, or Trigger Modes,
reads to the DATAX, DATAY, and DATAZ registers read data
stored in the FIFO. Each time any data is read from the FIFO
the oldest X, Y, and Z data is placed into the DATAX, DATAY
and DATAZ registers. If a single byte read operation is
performed, the remaining bytes worth of data will be lost.
Therefore, all axes of interest should be read in a burst (or
multi-byte) read operation. To ensure that the FIFO has
completely popped, there must be at least 5 μs between the end
of reading the data registers, signified by the transition to
register 0x38 from 0x37 or the CS pin going high, and the start
of new reads of the FIFO or reading the FIFO_STATUS
register. For SPI operation at 1.5 MHz or lower, the register
addressing portion of the transmission is sufficient delay to
ensure the FIFO has completely popped. It is necessary for SPI
operation greater than 1.5 MHz to de-assert the CS pin to
ensure a total of 5 μs, which is at most 3.4 μs at 5 MHz
operation. This is not a concern when using I2C, as the
communication rate is low enough to ensure a sufficient delay
between FIFO reads.
Vs = 2.5 V
Min.
Max.
Min.
X-Axis
+40
+130
+70
+225
Y-Axis
-40
-130
-70
-225
Z-Axis
+60
+210
+105
+365
Vs = 2.5 V
Min.
Max.
Min.
+65
+35
+113
Y-Axis
-20
-65
-35
-113
Z-Axis
+30
+105
+52
+183
Vs = 2.5 V
Min.
X-Axis
X-Axis
+80
+260
+140
Typ.
-80
-260
-140
-455
+120
+420
+210
+730
Vs = 2.5 V
Max.
Min.
+33
+17
Typ.
Max.
+57
-10
-33
-17
-57
+15
+53
+26
+92
Max.
Z-Axis
+10
Typ.
Z-Axis
+455
Y-Axis
Max.
Y-Axis
Vs = 3.3 V
Min.
Typ.
Table 11. Self Test output in LSB for 16 g 10-bit
Table 8. Self Test output in LSB for 2 g and Full-Resolution
Max.
Typ.
Vs = 2.5 V
+20
The Self Test feature on the ADXL345 exhibits a bi-modal
behavior which depends upon which phase of the clock Self
Test is enabled. Due to this, a typical value for Self Test is not
reported; however, the limits shown in Table 1 and below are
valid for both potential values.
Typ.
Max.
X-Axis
The ADXL345 incorporates a Self Test feature that effectively
tests both its mechanical and electronic systems. When the Self
Test function is enabled (via the SELF_TEST bit in the
DATA_FORMAT register), an electrostatic force is exerted on
the mechanical sensor. This electrostatic force moves the
mechanical sensing element in the same manner as
acceleration, and it is additive to the acceleration experienced
by the device. This added electrostatic force results in an output
change in the X, Y, and Z-axes. Because the electrostatic force is
proportional to VS2, the output change varies with VS.
Vs = 2.5 V
Typ.
Table 10. Self Test output in LSB for 8 g 10-bit
SELF TEST
Min.
Typ.
Vs = 3.3 V
Rev. PrA | Page 12 of 24
Preliminary Technical Data
ADXL345
REGISTER MAP
Table 12. Register Map
Hex
0
1
Dec
0
1
Name
DEVID
Reserved
Type
R
Reset Value
11100101
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R/W
R/W
R/W
R/W
R
R/W
R
R
R
R
R
R
R
R/W
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00001010
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
00000000
to
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
Reserved
THRESH_TAP
OFSX
OFSY
OFSZ
DUR
LATENT
WINDOW
THRESH_ACT
THRESH_INACT
TIME_INACT
ACT_INACT_CTL
THRESH_FF
TIME_FF
TAP_AXES
ACT_TAP_STATUS
BW_RATE
POWER_CTL
INT_ENABLE
INT_MAP
INT_SOURCE
DATA_FORMAT
DATAX0
DATAX1
DATAY0
DATAY1
DATAZ0
DATAZ1
FIFO_CTL
FIFO_STATUS
Rev. PrA | Page 13 of 24
Description
Device ID.
Reserved. Do not access.
Reserved. Do not access.
Reserved. Do not access.
Tap threshold
X axis offset
Y axis offset
Z axis offset
Tap duration
Tap latency
Tap window
Activity threshold
Inactivity threshold
Inactivity time
Axis enable control for ACT/INACT
Free-fall threshold
Free-fall time
Axis control for Tap/Double Tap
Source of Tap/Double Tap
Data Rate and Power Mode control
Power Save features control
Interrupt enable control
Interrupt mapping control
Source of interrupts
Data format control
X axis data
Y axis data
Z axis data
FIFO control
FIFO status
ADXL345
Preliminary Technical Data
0x23 WINDOW (read/write)
REGISTER DEFINITIONS
0x00 DEVID (read-only)
D7
1
D6
1
D5
1
D4
0
D3
0
D2
1
D1
0
D0
1
DEVID holds a fixed device ID code of 0xE5 (345 octal).
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
WINDOW is an unsigned time value representing the amount
of time after the expiration of LATENT during which a second
tap can begin. The scale factor is 1.25 ms/LSB. A zero value will
disable the Double Tap function.
0x1D THRESH_TAP (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
THRESH_TAP holds the threshold value for tap interrupts.
The data format is unsigned, so the magnitude of the tap event
is compared to THRESH_TAP. The scale factor is 62.5 mg/LSB
(i.e. 0xFF = +16 g). A zero value may result in undesirable
behavior if Tap/Double Tap interrupts are enabled.
0x24 THRESH_ACT (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
THRESH_ACT holds the threshold value for activity detection.
The data format is unsigned, so the magnitude of the activity
event is compared to THRESH_ACT. The scale factor is
62.5 mg/LSB. A zero value may result in undesirable behavior if
Activity interrupt is enabled.
0x1E, 0x1F, 0x20 OFSX, OFSY, OFSZ (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
OFSX/OFSY/OFSZ offer user offset adjustments in twoscompliment form with a scale factor of 15.6 mg/LSB (i.e. 0x7F =
+2 g).
0x21 DUR (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
DUR is an unsigned time value representing the maximum
time that an event must be above the THRESH_TAP threshold
to qualify as a tap event. The scale factor is 625 µs/LSB. A zero
value will prevent Tap/Double Tap functions from working.
0x22 LATENT (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
LATENT is an unsigned time value representing the wait time
from the detection of a tap event to the opening of the time
window WINDOW for a possible second tap event. The scale
factor is 1.25 ms/LSB. A zero value will disable the Double Tap
function.
0x25 THRESH_INACT (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
THRESH_INACT holds the threshold value for inactivity
detection. The data format is unsigned, so the magnitude of the
inactivity event is compared to THRESH_INACT. The scale
factor is 62.5 mg/LSB. A zero value may result in undesirable
behavior if Inactivity interrupt is enabled.
0x26 TIME_INACT (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
TIME_INACT is an unsigned time value representing the
amount of time that acceleration must be below the value in
THRESH_INACT for inactivity to be declared. The scale factor
is 1 second/LSB. Unlike the other interrupt functions, which
operate on unfiltered data(See Threshold description in
Application section), the inactivity function operates on the
filtered output data. At least one output sample must be
generated for the inactivity interrupt to be triggered. This will
result in the function appearing un-responsive if the
TIME_INACT register is set with a value less than the time
constant of the Output Data Rate. A zero value will result in an
interrupt when the output data is below THRESH_INACT.
Rev. PrA | Page 14 of 24
Preliminary Technical Data
ADXL345
0x2A TAP_AXES (read/write)
0x27 ACT_INACT_CONTROL (read/write)
D7
D6
D5
D4
D3
D2
D1
D0
ACT ACT_X ACT_Y ACT_Z INACT INACT_X INACT_Y INACT_Z
AC/DC Enable Enable Enable AC/DC Enable
Enable
Enable
X/Y/Z Enable: A ‘1’ enables X, Y, or Z participation in activity
or inactivity detection. A ‘0’ excludes the selected axis from
participation. If all of the axes are excluded, the function is
disabled.
AC/DC: A ‘0’ = DC coupled operation and a ‘1’ = AC coupled
operation. In DC coupled operation, the current acceleration is
compared with THRESH_ACT and THRESH_INACT directly
to determine whether activity or inactivity is detected. In AC
coupled operation for activity detection, the acceleration value
at the start of activity detection is taken as a reference value.
New samples of acceleration are then compared to this
reference value and if the magnitude of the difference exceeds
THRESH_ACT the device will trigger an activity interrupt. In
AC coupled operation for inactivity detection, a reference value
is used again for comparison and is updated whenever the
device exceeds the inactivity threshold. Once the reference
value is selected, the device compares the magnitude of the
difference between the reference value and the current
acceleration with THRESH_INACT. If the difference is below
THRESH_INACT for a total of TIME_INACT, the device is
considered inactive and the inactivity interrupt is triggered.
0x28 THRESH_FF (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
THRESH_FF holds the threshold value for Free-Fall detection.
The data format is unsigned. The root-sum-square(RSS) value
of all axes is calculated and compared to the value in
THRESH_FF to determine if a free fall event may be occurring.
The scale factor is 62.5 mg/LSB. A zero value may result in
undesirable behavior if Free-Fall interrupt is enabled. Values
between 300 and 600 mg (0x05 to 0x09) are recommended.
0x29 TIME_FF (read/write)
D7
MSB
D6
D6
D5
D5
D4
D4
D3
D3
D2
D2
D1
D1
D0
LSB
TIME_FF is an unsigned time value representing the minimum
time that the RSS value of all axes must be less than
THRESH_FF to generate a Free-Fall interrupt. The scale factor
is 5 ms/LSB. A zero value may result in undesirable behavior if
Free-Fall interrupt is enabled. Values between 100 to 350 ms
(0x14 to 0x46) are recommended.
D7
D6
D5
D4
D3
0
0
0
0
SUPPRESS
D2
D1
D0
TAP_X TAP_Y TAP_Z
Enable Enable Enable
TAP_X/Y/Z Enable: A ‘1’ in TAP_X, Y, or Z Enable enables X,
Y, or Z participation in Tap detection. A ‘0’ excludes the
selected axis from participation in Tap detection.
Setting the SUPPRESS bit suppresses Double Tap detection if
acceleration greater than THRESH_TAP is present between
taps. See Tap Detection in the Application Section for more
details.
0x2B ACT_TAP_STATUS (read)
D7
X
D6
D5
D4
D3
D2
D1
D0
ACT_X ACT_Y ACT_Z
TAP_X TAP_Y TAP_Z
ASLEEP
Source Source Source
Source Source Source
X/Y/Z Source: Indicate the first axis involved in a Tap or
Activity event. A ‘1’ corresponds to involvement in the event
and a ‘0’ corresponds to no involvement. They are not cleared,
but overwritten by new data. ACT_TAP_STATUS should be
read before clearing the interrupt. Disabling an axis from
participation will clear the corresponding Source bit when the
next Activity or Tap/Double Tap event occurs.
ASLEEP: A ‘1’ indicates that the part is in the Auto Sleep Mode.
A ‘0’ indicates that the part is not using Auto Sleep Mode. See
the POWER_CTL description for more information on Auto
Sleep Mode.
0x2C BW_RATE (read/write)
D7
D6
D5
D4
X
X
X
LOW_POWER
D3
D2
D1
D0
RATE
LOW_POWER: A ‘0’ = Normal operation and a ‘1’ = Reduced
power operation with somewhat higher noise. (See Power
Modes section for details).
RATE: Selects device bandwidth and output data rate. See Table
5 and Table 6 for details. Default value is 0x0A, or 100 Hz
Output Data Rate. An Output Data Rate should be selected that
is appropriate for the communication protocol and frequency
selected. Selecting too high of an Output Data Rate with a low
communication speed will result in samples being discarded.
Rev. PrA | Page 15 of 24
ADXL345
Preliminary Technical Data
0x2D POWER_CTL (read/write)
D7
D6
X
X
D5
D4
0x2E INT_ENABLE (read/write)
D3
D2
LINK AUTO_SLEEP MEASURE SLEEP
D1
D0
WAKEUP
LINK: A ‘1’ with both the activity and inactivity functions
enabled will delay the start of the activity function until
inactivity is detected. Once activity is detected, inactivity
detection will begin and prevent the detection of activity. This
bit serially links the activity and inactivity functions. When ‘0’
the inactivity and activity functions are concurrent. Additional
information can be found in the Application section under Link
Mode.
D7
D6
D5
D4
D3
D2
D1
D0
DATA_READY SINGLE_TAP DOUBLE_TAP ACTIVITY INACTIVITY FREE_FALL WATERMARK OVERRUN
Setting bits with a value of ‘1’ in this register to enable their
respective functions and generate interrupts. A value of ‘0’ will
prevent the functions from generating an interrupt.
DATA_READY, WATERMARK, and OVERRUN bits only
enable the interrupt output; the functions are always enabled. It
is recommended that interrupts be configured before enabling
their outputs.
AUTO_SLEEP: A ‘1’ sets the ADXL345 to switch to Sleep Mode
when inactivity (acceleration has been below THRESH_INACT
for at least TIME_INACT) is detected and the LINK bit is set.
A ‘0’ disables automatic switching to Sleep Mode. See SLEEP
for further description.
0x2F INT_MAP (read/Write)
MEASURE: A ‘0’ places the part into standby mode and a ‘1’
places the part into measurement mode. The ADXL345 powers
up in standby mode with minimum power consumption.
Any ‘0’ bits in this register send their respective interrupts to
the INT1 pin. Bits set with a ‘1’ send their respective interrupts
to the INT2 pin. All selected interrupts for a given pin are
ORed.
SLEEP: A ‘0’ puts the part into a normal mode of operation. A
‘1’ places the part into Sleep Mode. This suppresses
DATA_READY, stops sending data to the FIFO, and switches
the sampling rate to one specified by the WAKEUP bits. In
Sleep Mode, only the Activity function can be used.
When clearing the LINK, AUTO_SLEEP, or SLEEP bits, it is
recommended that the part be placed into Standby when
clearing the bits and then re-enabling Measurement mode
during a following write. This is done to ensure the device is
properly biased if Sleep mode is manually disabled. Not
toggling Measurement mode may result in the first few after
LINK, AUTO_SLEEP, or SLEEP is cleared having additional
noise, especially if the device was asleep when the bits were
cleared.
WAKEUP: Controls the frequency of readings in Sleep Mode as
shown in
D7
D6
D5
D4
D3
D2
D1
D0
DATA_READY SINGLE_TAP DOUBLE_TAP ACTIVITY INACTIVITY FREE_FALL WATERMARK OVERRUN
0x30 INT_SOURCE (read)
D7
D6
D5
D4
D3
D2
D1
D0
DATA_READY SINGLE_TAP DOUBLE_TAP ACTIVITY INACTIVITY FREE_FALL WATERMARK OVERRUN
Bits set with a ‘1’ in this register indicate that their respective
functions have triggered. A value of ‘0’ indicates that the
corresponding event has not occurred. DATA_READY,
WATERMARK and OVERRUN bits will always be set if
corresponding event occurs, regardless of INT_ENABLE, and
are cleared by reading data from the DATAX/Y/Z registers.
DATA_READY and WATERMARK may require multiple reads,
as per the FIFO Mode descriptions in the FIFO section. Other
bits are cleared by reading INT_SOURCE.
Table 13 below:
0x31 DATA_FORMAT (read/write)
Table 13. WAKEUP Rates
D1
0
0
1
1
D0
0
1
0
1
D7
Frequency (Hz)
8
4
2
1
D6
SELF_TEST SPI
D5
D4
INT_INVERT
X
D3
D2
FULL_RES JUSTIFY
D1
D0
RANGE
DATA_FORMAT controls the presentation of data at registers
0x32 to 0x37. All data, except ±16 g range, must be clipped to
avoid rollover.
SELF_TEST: A ‘1’ applies a Self Test force to the sensor causing
a shift in the output data. A value of ‘0’ disable Self Test.
Rev. PrA | Page 16 of 24
Preliminary Technical Data
ADXL345
SPI: A value of ‘1’ sets the device to 3-wire SPI and a value of ‘0’
sets the device to 4-wire SPI.
TRIGGER: A value of ‘0’ sets the trigger event of Trigger Mode
to INT1 and a value of ‘1’ sets the trigger event to INT2.
INT_INVERT: A value of ‘0’ sets the interrupts to Active High
while a value of ‘1’ sets the interrupts to Active Low.
SAMPLES: Function depends on the FIFO Mode as shown in
Table 16 below. Entering a value of zero in SAMPLES will
immediately set the WATERMARK status bit in
INT_SOURCE, regardless of FIFO mode. Undesirable
operation may occur if a value of zero is used for SAMPLES
when Trigger Mode is used.
FULL_RES: When this bit is set with a value of ‘1’ the device is
in Full-Resolution Mode, where the output resolution increases
with RANGE to maintain a 4 mg/LSB scale factor. When this
bit is ’0’ the device is in 10-bit Mode and RANGE determine the
maximum g-Range and scale factor.
JUSTIFY: A ‘1’ = Left (MSB) justified and a ‘0’ = Right justified
with sign extension.
RANGE: Sets the g-Range based on Table 14 below.
Table 14. g-Range Setting
D1
0
0
1
1
D0
0
1
0
1
g-Range
±2 g
±4 g
±8 g
±16 g
Table 15. FIFO Modes
D7 D6 MODE Function
0
0
0 Bypass
1 FIFO
The FIFO is bypassed
FIFO collects up to 32 values then
stops collecting data
1
0 Stream FIFO holds the last 32 data values.
Once full, the FIFO’s oldest data is
lost as it is replaced with newer data
1
1 Trigger When triggered by the TRIGGER the
FIFO holds the last 32 data values and
stops when full.
0x32, 0x33 DATAX0, DATAX1 (read only)
D7
D6
D5
D4
D3
D2
D1
D0
Table 16. SAMPLES Functions
FIFO Mode Samples Function
None
Bypass
0x34, 0x35 DATAY0, DATAY1 (read only)
FIFO
D7
D6
D5
D4
D3
D2
D1
D0
Stream
Trigger
0x36, 0x37 DATAZ0, DATAZ1 (read only)
D7
D6
D5
D4
D3
D2
D1
Specifies how many FIFO entries are need to trigger
a Watermark interrupt
Specifies how many FIFO entries are need to trigger
a Watermark interrupt
Specifies how many FIFO samples before the trigger
event are retained in the FIFO buffer
D0
0x39 FIFO_STATUS (read)
These six bytes hold the output data for each axis. The output
data is two’s complement with DATAx0 as the LSByte and
DATAx1 as the MSByte. The DATA_FORMAT register (0x31)
controls the format of the data. It is recommended that a burst
read of all of the registers is performed to prevent the change of
data between reads of sequential registers.
0x38 FIFO_CTL (read/write)
D7
D6
D5
FIFO_MODE TRIGGER
D4
D3
D2
D1
D0
SAMPLES
FIFO_MODE: Corresponds to the FIFO Mode as shown in
Table 15 below.
D7
FIFO_TRIG
D6
X
D5
D4
D3
D2
D1
D0
ENTRIES
FIFO_TRIG: A ‘1’ corresponds to a trigger event occurring
while a ‘0’ means that a FIFO trigger event has not yet occurred.
ENTRIES: Reports how many data values are stored in the
FIFO. To collect the data from the FIFO, access is through the
standard DATAX, DATAY, and DATAZ registers. FIFO reads
must be done in burst, or multi-byte, mode as each FIFO level is
cleared after any read, single- or multi-byte, of the FIFO. The
FIFO stores a maximum of 32 entries, which equates to a
maximum of 33 entries available at any given time, due to the
fact that an additional entry is available at the output filter of
device.
Rev. PrA | Page 17 of 24
ADXL345
Preliminary Technical Data
until the opening of the time window, whose value is
contained in the WINDOW register, for a possible
second tap.
APPLICATION
POWER SUPPLY DECOUPLING
In many applications, a 0.1 μF capacitor at VS and VDD I/O placed
close to the ADXL345 supply pins adequately decouples the
accelerometer from noise on the power supply. However, in
applications where noise is present at the 50 kHz internal clock
frequency, or any harmonic thereof, additional care in power
supply bypassing is required because this noise may cause errors
in acceleration measurement. If additional decoupling is
necessary, a 10 Ω resistor or ferrite in series with VS and an
additional larger bypass capacitor (2.2 µF or greater) at VS may
be helpful.
•
The interval time after the expiration of LATENT is
defined by the WINDOW register and is the period of
time during which a second tap must begin. The
second tap need not finish before the end of
WINDOW.
FIRST TAP
XHI BW
Care should be taken that the connection from the ADXL345
ground to the power supply ground be low impedance because
noise transmitted through ground has an effect similar to noise
transmitted through VS.
SECOND TAP
THRESHOLD
(THRESHC)
TIME LIMIT FOR
TAPS (DUR)
ACCELEROMETER
PCB
DOUBLE TAP INTERRUPT
Figure 11. Tap Interrupt Function with Valid Single and Double Taps
If only the single tap function is in use, the single tap interrupt
will trigger at the point that the acceleration goes below the
threshold as long as DUR is not exceeded. If both single and
double tap functions are in use the single tap interrupt will
trigger once the double tap event has been either validated or
invalidated.
Several events can occur to invalidate the second tap of a double
tap event. First, if the SUPPRESS bit in the TAP_AXES register
is set, any acceleration spikes above the threshold during the
LATENT time window will invalidate the double tap as seen in
Figure 12.
06238-014
MOUNTING POINTS
TIME WINDOW FOR
SECOND TAP (INTVL)
SINGLE TAP INTERRUPT
INT
The ADXL345 should be mounted on the PCB in a location
close to a hard mounting point of the PCB to the case.
Mounting the ADXL345 at an unsupported PCB location (that
is, at the end of a “lever,” or in the middle of a “trampoline”), as
shown in Figure 10, may result in large apparent measurement
errors because the accelerometer will see the resonant vibration
of the PCB. Locating the accelerometer near a hard mounting
point ensures that any PCB resonances at the accelerometer are
above the accelerometer’s mechanical sensor resonant
frequency and, therefore, effectively invisible to the
accelerometer.
LATENCY
TIME
(LATENT)
Figure 10. Where Not to Mount an Accelerometer
INVALIDATES DOUBLE TAP IF
SUPPRESS BIT SET
The tap interrupt function is capable of detecting either single
or double taps. The following parameters are shown graphically
in Figure 11 for a valid single and valid double tap event:
•
Tap detection threshold is defined by the
THRESH_TAP register.
•
Maximum tap duration time is defined by the DUR
register.
•
Tap latency time is defined by the LATENT register
and is the waiting period from the end of the first tap
XHI BW
TAP DETECTION
TIME LIMIT
FOR TAPS
(DUR)
LATENCY
TIME (LATENT)
TIME WINDOW FOR SECOND
TAP (WINDOW)
Figure 12. Double Tap event invalid due to high-g event with SUPPRESS set
Rev. PrA | Page 18 of 24
06238-011
MECHANICAL CONSIDERATIONS FOR MOUNTING
Preliminary Technical Data
ADXL345
A double tap event can also be invalidated if an acceleration
above the threshold is detected at the start of WINDOW,
resulting in an invalid double tap at the start of WINDOW,
shown in Figure 13. Additionally, a double tap event can be
invalidated by having an acceleration exceed DUR, resulting in
an invalid double tap at the end of DUR for the second tap
event, also seen in Figure 13.
The lower Output Data Rates are achieved by decimation of a
common sampling frequency inside the device. The activity,
free-fall and tap/double tap detection functions are performed
using the un-filtered data. Since the output data is filtered, the
high frequency and high-g data that is used to determine
activity, free-fall and tap/double tap events may not be present if
the output of the accelerometer is examined. This may result in
trigger events appearing to occur when acceleration does not
appear to trigger an event, such as exceeding a threshold or
remaining below a threshold for a certain period of time.
XHI BW
INVALIDATES DOUBLE TAP
AT START OF WINDOW
THRESHOLD
LINK MODE
The LINK function can be used to reduce the number of
activity interrupts the processor must service by only looking
for activity after inactivity. For proper operation of the link
feature, the processor must still respond to the activity and
inactivity interrupts by reading the INT_SOURCE register to
clear them. If the activity interrupt is not cleared, the part will
not go into Auto Sleep Mode. The ASLEEP bit in the
ACT_TAP_STATUS register indicates if the part is in Auto
Sleep Mode.
TIME LIMIT
FOR TAPS
(DUR)
TIME LIMIT
FOR TAPS
(DUR)
LATENCY
TIME
(LATENT)
TIME WINDOW FOR
SECOND TAP (WINDOW)
XHI BW
TIME LIMIT
FOR TAPS
(DUR)
INVALIDATES
DOUBLE TAP AT
END OF DUR
Figure 13. Tap Interrupt Function with Invalid Double Taps
Single taps, double taps, or both may be detected by setting
their respective bits in the INT_ENABLE register. Control over
participation of each of the three axes in tap/double tap
detection is exerted by setting the appropriate bits in the
TAP_AXES register. For the double tap function to operate,
both LATENT and WINDOW must be non-zero.
Every mechanical system will have somewhat different
tap/double tap response based on the system’s mechanical
characteristics, so some experimentation with values for the
LATENT, WINDOW, and THRESH_TAP registers will be
required. In general a good starting point is LATENT>0x10,
WINDOW>0x10, and THRESH_TAP>3g. Setting very low
values in the LATENT, WINDOW, and/or THRESH_TAP
registers may result in unpredictable response due to the
accelerometer picking up “echoes” of the tap inputs.
After a tap interrupt is received, the first axis to exceed the
THRESH_TAP level is reported in the ACT_TAP_STATUS
register. This register is never cleared, but overwritten with new
data.
Rev. PrA | Page 19 of 24
ADXL345
Preliminary Technical Data
RECOMMENDED PWB LAND PATTERN
3.3400
1.0500
0.5500
0.2500
3.0500
0.2500
1.1450
06238-015
0.3400
5.34
Figure 14. Recommended Printed Wiring Board Land Pattern
(Dimensions Shown in Millimeters)
Rev. PrA | Page 20 of 24
Preliminary Technical Data
ADXL345
RECOMMENDED SOLDERING PROFILE
CRITICAL ZONE
TL TO TP
tP
TP
TL
tL
TSMAX
TSMIN
tS
RAMP-DOWN
PREHEAT
06238-016
TEMPERATURE
RAMP-UP
t25°C TO PEAK
TIME
Figure 15. Recommended Soldering Profile
Table 17. Recommended Soldering Profile1
Profile Feature
Average Ramp Rate (TL to TP)
Preheat
Minimum Temperature (TSMIN)
Maximum Temperature (TSMAX)
Time (TSMIN to TSMAX)(tS)
TSMAX to TL
Ramp-Up Rate
Time Maintained Above Liquidous (TL)
Liquidous Temperature (TL)
Time (tL)
Peak Temperature (TP)
Time Within 5°C of Actual Peak Temperature (tP)
Ramp-Down Rate
Time 25°C to Peak Temperature
Sn63/Pb37
3°C/sec max
Rev. PrA | Page 21 of 24
Condition
Pb-Free
3°C/sec max
100°C
150°C
60 sec to 120 sec
150°C
200°C
60 sec to 180 sec
3°C/sec max
3°C/sec max
183°C
60 sec to 150 sec
240 + 0/−5°C
10 sec to 30 sec
6°C/sec max
6 minutes max
217°C
60 sec to 150 sec
260 + 0/−5°C
20 sec to 40 sec
6°C/sec max
8 minutes max
ADXL345
Preliminary Technical Data
OUTLINE DIMENSIONS
1
Figure 35. 14-Lead Land Grid Array Package [LGA]
3 mm × 5 mm Body, Thick Quad
Dimensions shown in millimeters
Lead finish: matte tin
ORDERING GUIDE
Model
ADXL345BCCZ1
Measurement
Range
±2, 4, 8, 16g
Specified
Voltage (V)
2.5
Temperature
Range
−40°C to +85°C
ADXL345BCCZ–RL1
±2, 4, 8, 16g
2.5
−40°C to +85°C
ADXL345BCCZ–RL71
±2, 4, 8, 16g
2.5
−40°C to +85°C
EVAL-ADXL345Z1
1
Package Description
14-Lead Land Grid Array
Package [LGA]
14-Lead Land Grid Array
Package [LGA]
14-Lead Land Grid Array
Package [LGA]
Evaluation Board
Z = Pb-free part.
Rev. PrA | Page 22 of 24
Package
Option
TBD
TBD
TBD
Preliminary Technical Data
ADXL345
NOTES
Rev. PrA | Page 23 of 24
ADXL345
Preliminary Technical Data
NOTES
©2008 Analog Devices, Inc. All rights reserved. Trademarks and
registered trademarks are the property of their respective
owners.
PR07925-0-11/08(PrA)