HVCA 2CL60KV0.1A

HVCA
2CL60KV0.1A (60kV 100mA )
HIGH VOLTAGE AXIAL LEAD FLAT PACK RECTIFIER
FIGURE
13
Finds use in applications such as X-ray
machines and electrostatic precipitators.
HVS
Outline Drawings : mm
Axial Lead Glass Passivated Rectifier Assembly
FIGURE
13
Lead Diameter 1.20
8.00
9.00
23 Min.
60.00
Maximum Ratings and Characteristics
Absolute Maximum Ratings
Items
Symbols
Condition
2CL60KV0.1A
Units
60
kV
0.1
A peak
I FSM
10
A peak
Junction Temperature
Tj
155
°C
Allowable Operation Case Temperature
Tc
125
°C
Storage Temperature
Tstg
-40 to +155
°C
Repetitive Peak Renerse Voltage
Average Output Current
Suege Current
V RRM
IO
Ta=25°C,Resistive Load
Electrical Characteristics (Ta=25°C Unless otherwise specified )
Items
Symbols
Conditions
2CL60KV0.1A
Units
Maximum Forward Voltage Drop
VF
at 25°C,IF =IF(AV)
80
V
Maximum Reverse Current
IR1
at 25°C,VR =VRRM
5.0
uA
IR2
at 100°C,V R =VRRM
50
uA
Maximum Reverse Recovery Time
Trr
at 25°C
--
nS
Junction Capacitance
Cj
at 25°C,VR=0V,f=1MHz
--
pF
GETE ELECTRONICS CO.,LTD
Http://www.getedz.com
E-mail:[email protected]
2012