TI 74AC11151

74AC11151
1-OF-8 DATA SELECTOR/MULTIPLEXER
SCAS066A – JUNE 1989 – REVISED APRIL 1993
•
•
•
•
•
•
D OR N PACKAGE
(TOP VIEW)
8-Line to 1-Line Multiplexers Can Perform
as Boolean Function Generators,
Parallel-to-Serial Converters, or Data
Source Selectors
Flow-Through Architecture Optimizes
PCB Layout
Center-Pin VCC and GND Configurations
Minimize High-Speed Switching Noise
EPIC  (Enhanced-Performance Implanted
CMOS) 1-µm Process
500-mA Typical Latch-Up Immunity
at 125°C
Package Options Include Plastic
Small-Outline Packages and Standard
Plastic 300-mil DIPs
D0
OE
Y
GND
W
A
B
C
1
16
2
15
3
14
4
13
5
12
6
11
7
10
8
9
D1
D2
D3
D4
VCC
D5
D6
D7
description
This monolithic data selector/multiplexer provides full binary decoding to select one-of-eight data sources. The
strobe output-enable (OE) input must be at a low logic level to enable the inputs. A high level at the strobe
terminal forces the W output high and the Y output low.
The 74AC11151 is characterized for operation from – 40°C to 85°C.
logic symbol†
FUNCTION TABLE
INPUTS
SELECT
OUTPUTS
2
C
B
A
STROBE
OE
X
X
X
H
L
H
L
L
L
L
D0
D0
L
L
H
L
D1
D1
C
Y
W
OE
A
B
L
H
L
L
D2
D2
D0
L
H
H
L
D3
D3
D1
H
L
L
L
D4
D4
D2
H
L
H
L
D5
D5
D3
H
H
L
L
D6
D6
H
H
H
L
D7
D7
D5
H = high level, L= low level, X = irrelevant
D0, D1, . . . D7 = the level of the respective D input
D6
D4
D7
6
MUX
EN
0
7
8
1
16
15
14
13
11
10
9
G0
7
2
0
1
3
Y
5
W
2
3
4
5
6
7
† This symbol is in accordance with ANSI/IEEE Std 91-1984
and IEC Publication 617-12.
EPIC is a trademark of Texas Instruments Incorporated.
Copyright  1993, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–1
74AC11151
1-OF-8 DATA SELECTOR/MULTIPLEXER
SCAS066A – JUNE 1989 – REVISED APRIL 1993
logic diagram (positive logic)
OE
D0
D1
D2
D3
1
16
15
14
3
Data
Inputs
D4
D5
D6
D7
A
Data
Select
(Binary)
2
B
C
13
5
Y
W
11
10
9
6
7
8
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Supply voltage range, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to 7 V
Input voltage range, VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Output voltage range, VO (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VCC + 0.5 V
Input clamp current, IIK (VI < 0 or VI > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA
Output clamp current, IOK (VO < 0 or VO > VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous output current, IO (VO = 0 to VCC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 50 mA
Continuous current through VCC or GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 100 mA
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed.
2–2
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
74AC11151
1-OF-8 DATA SELECTOR/MULTIPLEXER
SCAS066A – JUNE 1989 – REVISED APRIL 1993
recommended operating conditions
VCC
Supply voltage
VIH
High-level input voltage
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
MIN
NOM
MAX
3
5
5.5
V
3.85
0.9
VIL
Low-level input voltage
VI
VO
Input voltage
0
Output voltage
0
IOH
High-level output current
1.35
VCC = 5.5 V
Input transition rise or fall rate
TA
Operating free-air temperature
V
V
–4
– 24
mA
– 24
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
∆t /∆v
V
1.65
VCC
VCC
VCC = 3 V
VCC = 4.5 V
VCC = 5.5 V
Low-level output current
V
2.1
3.15
VCC = 3 V
VCC = 4.5 V
IOL
UNIT
12
24
mA
24
0
10
ns / V
– 40
85
°C
electrical characteristics over recommended operating free-air temperature range (unless
otherwise noted)
PARAMETER
TEST CONDITIONS
IOH = – 50 µA
VOH
MIN
3V
2.9
2.9
4.5 V
4.4
4.4
5.4
5.4
3V
2.58
2.48
4.5 V
3.94
3.8
IOH = – 24 mA
A
5.5 V
4.94
IOH = – 75 mA†
5.5 V
IOL = 12 mA
IOL = 24 mA
II
ICC
TA = 25°C
MIN
TYP
MAX
5.5 V
IOH = – 4 mA
IOL = 50 µA
VOL
VCC
MAX
UNIT
V
4.8
3.85
3V
0.1
0.1
4.5 V
0.1
0.1
5.5 V
0.1
0.1
3V
0.36
0.44
4.5 V
0.36
0.44
5.5 V
0.36
0.44
V
IOL = 75 mA†
5.5 V
VI = VCC or GND
VI = VCC or GND,
5.5 V
± 0.1
±1
µA
5.5 V
8
80
µA
IO = 0
Ci
VI = VCC or GND
5V
3.5
† Not more than one output should be tested at a time, and the duration of the test should not exceed 10 ms.
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
1.65
pF
2–3
74AC11151
1-OF-8 DATA SELECTOR/MULTIPLEXER
SCAS066A – JUNE 1989 – REVISED APRIL 1993
switching characteristics over recommended operating free-air temperature range,
VCC = 3.3 V ± 0.3 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A B,
A,
B or C
Y
tPLH
tPHL
A B,
A,
B or C
W
tPLH
tPHL
Any D
Y
tPLH
tPHL
Any D
W
tPLH
tPHL
OE
Y
tPLH
tPHL
OE
W
TA = 25°C
MIN
MAX
3.2
8.9
10.7
3.2
12
3.4
8.9
10.8
3.4
12.1
3.2
8.6
10.3
3.2
11.6
3.1
8.7
10.7
3.1
12
1.9
6.5
8.1
1.9
9.2
1.9
6.4
8.1
1.9
8.9
1.7
6.1
7.7
1.7
8.6
1.9
6.4
8
1.9
8.8
1.3
4
5.5
1.3
6
1.6
4.5
5.9
1.6
6.5
2
5.2
6.7
2
7.4
1.7
4.7
6.2
1.7
6.7
UNIT
ns
ns
ns
ns
ns
ns
switching characteristics over recommended operating free-air temperature range,
VCC = 5 V ± 0.5 V (unless otherwise noted) (see Figure 1)
PARAMETER
FROM
(INPUT)
TO
(OUTPUT)
tPLH
tPHL
A B,
B or C
A,
Y
tPLH
tPHL
A B,
A,
B or C
W
tPLH
tPHL
Any D
Y
tPLH
tPHL
Any D
W
tPLH
tPHL
OE
Y
tPLH
tPHL
OE
W
MIN
TA = 25°C
TYP
MAX
MIN
MAX
2.5
5.4
7.3
2.5
8.3
2.7
5.6
7.5
2.7
8.5
2.6
5.3
7.2
2.6
8.1
2.6
5.4
7.4
2.6
8.4
1.5
4.1
5.8
1.5
6.5
1.5
4
5.7
1.5
6.4
1.4
3.7
5.5
1.4
6
1.6
4.1
5.8
1.6
6.4
1.1
2.7
4.2
1.1
4.6
1.4
3.1
4.6
1.4
5
1.7
3.5
5.1
1.7
5.6
1.4
3.1
4.6
1.4
5
UNIT
ns
ns
ns
ns
ns
ns
operating characteristics, VCC = 5 V, TA = 25°C
PARAMETER
Cpd
2–4
TEST CONDITIONS
Power dissipation capacitance
CL = 50 pF,
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
f = 1 MHz
TYP
UNIT
52
pF
74AC11151
1-OF-8 DATA SELECTOR/MULTIPLEXER
SCAS066A – JUNE 1989 – REVISED APRIL 1993
PARAMETER MEASUREMENT INFORMATION
VCC
Input
(see Note B)
50%
50%
0V
tPHL
tPLH
From Output
Under Test
CL = 50 pF
(see Note A)
500 Ω
In-Phase
Output
50% VCC
tPLH
tPHL
Out-of-Phase
Output
VOH
50% VCC
VOL
50% VCC
VOH
50% VCC
VOL
VOLTAGE WAVEFORMS
LOAD CIRCUIT
NOTES: A. CL includes probe and jig capacitance.
B. Input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr = 3 ns, tf = 3 ns.
C. The outputs are measured one at a time with one input transition per measurement.
Figure 1. Load Circuit and Voltage Waveforms
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
2–5
74AC11151
1-OF-8 DATA SELECTOR/MULTIPLEXER
SCAS066A – JUNE 1989 – REVISED APRIL 1993
2–6
POST OFFICE BOX 655303
• DALLAS, TEXAS 75265
IMPORTANT NOTICE
Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue
any product or service without notice, and advise customers to obtain the latest version of relevant information
to verify, before placing orders, that information being relied on is current and complete. All products are sold
subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those
pertaining to warranty, patent infringement, and limitation of liability.
TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in
accordance with TI’s standard warranty. Testing and other quality control techniques are utilized to the extent
TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily
performed, except those mandated by government requirements.
CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF
DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (“CRITICAL
APPLICATIONS”). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR
WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER
CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO
BE FULLY AT THE CUSTOMER’S RISK.
In order to minimize risks associated with the customer’s applications, adequate design and operating
safeguards must be provided by the customer to minimize inherent or procedural hazards.
TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent
that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other
intellectual property right of TI covering or relating to any combination, machine, or process in which such
semiconductor products or services might be or are used. TI’s publication of information regarding any third
party’s products or services does not constitute TI’s approval, warranty or endorsement thereof.
Copyright  1998, Texas Instruments Incorporated