FAIRCHILD FM75MM8X

www.fairchildsemi.com
FM75
Low Voltage 2-Wire Digital Temperature Sensor
with Thermal Alarm
Features
Description
•
•
•
•
•
•
Within the FM75 are: a high-precision CMOS temperature
sensor, a Delta-Sigma analog-to-digital converter and a
SMBus compatible serial digital interface. Typical accuracy
is ±2°C over the full temperature range of –40°C to 125°C
and to ±1°C over the range of 0°C to 100°C, with 9- to 12-bit
resolution. Default resolution is 9 bits.
User Configurable to 9, 10, 11 or 12-bit Resolution
Precision Calibrated to ±1°C from 0°C to 100°C Typical
Temperature Range: –40°C to 125°C
Low Operating Current (less than 250µA)
Low Self Heating (0.2°C max in still air)
Operating Voltage Range: 2.7V to 5.5V
Thermal Alarm output, OS (Over-limit Signal) supports
Interrupt and Comparator modes. OS is active, if the
user-programmable trip-temperature is exceeded. When
the temperature falls below the trip-temperature plus the
user-programmable hysteresis limit, OS is disabled.
Applications
•
•
•
•
•
•
•
•
•
Battery Management
FAX Management
Printers
Portable Medical Instruments
HVAC
Power Supply Modules
Disk Drives
Computers
Automotive
Available packages are surface mount SOIC-8 (SOP-8) and
MSOP-8.
Application Diagram
2.7 to 5.5V
8
A0
User
Programmable
Address
A1
A2
SMBus
Interface
SDA
SCL
7
6
5
1
FM75
3
O.S.
8 Pin
Configuration
2
4
REV. 1.0.5 10/2/03
FM75
PRODUCT SPECIFICATION
Pin Assignments
SDA
1
8
VDD
SCL
2
7
A0
FM75
O.S.
3
6
A1
GND
4
5
A2
Pin Descriptions
2
Pin #
Name
Direction
1
SDA
Input/Output
Description
Serial Data. Open drain to I/O-data pin for two-wire interface.
2
SCL
Input
3
O.S.
Output
Over-Limit Signal. Open drain thermostat output that indicates if the
temperature has exceeded user-programmable limits. Default is
active low.
Serial Clock. Clock for 2-wire serial interface.
4
GND
Supply
Ground
5, 6, 7
A0, A1, A2
Input
8
VDD
Supply
Address LSBs. User selectable address pins for the 3 LSBs of the
serial interface address.
Supply Voltage
REV. 1.0.5 10/2/03
PRODUCT SPECIFICATION
FM75
Absolute Maximum Ratings1
Parameter
Min.
Typ.
Max.
Units
Supply Voltage
+7
V
Output Voltage
VCC + 0.5
V
Output Current
10
mA
+150
°C
220
°C
2000
250
V
V
Storage Temperature Range
-60
Lead Soldering Temperature
ESD2
Human Body Model
Machine Model
Notes:
1. Absolute maximum ratings are limits beyond which operation may cause permanent damage to the device. These are stress
ratings only; functional operation at or above these limits is not implied.
2. Human Body Model: 100pF capacitor discharged through a 1.5kΩ resistor into each pin. Machine Model: 200pF capacitor
discharged directly into each pin.
Electrical Characteristics3
(-40°C ≤ TA ≤ +125°C, VCC = 5.0V unless otherwise noted. Specifications subject to change without notice.)
Parameter
Symbol
Specified Temperature Range
Temperature Conversion
Conditions
TMIN, TMAX
Min.
Typ.
-40
Time4
Max.
Units
+125
°C
90
Accuracy5
TA = +25°C
TA = +100°C
TA = –40°C (TMIN)
TA = +125°C (TMAX)
-2
-3
-4
-4
ms
+2
+3
+4
+4
°C
Notes:
3. These specifications are guaranteed only for the test conditions listed.
4. This specification only indicates how often temperature information is updated to the Temperature Register. The FM75 can
be read at any time without interrupting the temperature conversion process.
5. Accuracy (expressed in °C) = Difference between the FM75 output temperature and the measured temperature.
Logic Electrical Characteristics
Parameter
Symbol
Conditions
Min
Typ
Max
Units
Min. Input Voltage Logic High
VIH
VDD x 0.7
VDD + 0.5
V
Max. Input Voltage Logic Low
VIL
-0.3
VDD x 0.3
V
Max. Output Voltage Logic
Low
VOL
VDD = 5V, IOL = -3mA
VDD = 3V, IOL = -1.5mA
0.36
0.36
V
V
Quiescent Supply Current
IDD
Interface inactive R/W
Activity on SDA
250
350
500
700
µA
IDD-SD
Interface inactive R/W
Activity on SDA
0.15
83
1
150
µA
±0.1
±1.0
µA
3
mA
5
µA
CL = 400pF, IOL = -3mA
250
ns
All Digital Inputs
20
pF
Shutdown Current
Input Leakage Current
IIN
VIN = 0V or 5V, TA = 25°C
-40°C < TA < 125°C
Output Sink Current
IOL
TA = 25°C, VOL = 0.4V
Output Leakage Current
ILEAK
Output Transition Time
tF
Input Capacitance
REV. 1.0.5 10/2/03
CIN
VOH = 5V, VDD = 0V
0.001
3
FM75
PRODUCT SPECIFICATION
Serial Port Timing
Parameter
Symbol
SCL Clock Period
Conditions
Min.
tSCL
SCL Clock Transition Time
Typ.
1.0
tT:LH, tT:HL
Max.
Units
100
µs
300
ns
SCL Clock Low Period
tLOW
0.470
SCL Clock High Period
tHIGH
0.400
Bus free time between a Stop and
a new Start Condition
tBUF
1.0
µs
Data in Set-up to SCL High
tSU:DAT
100
ns
Data Out Stable after SCL Low
tHD:DAT
0
ns
SCL Low Set-up to SDA Low
(Repeated Start Condition)
tSU:STA
100
ns
SCL High Hold after SDA Low
(Start Condition)
tHD:STA
100
ns
SDA High after SCL High
(Stop Condition
tSU:STO
100
ns
Time in which a FM75 must be
operational after a power-on reset
µs
50
µs
500
tPOR
ms
tSCL
SCL
tSU:STA
tHD:STA
tSU:DAT
tSU:STO
SDA
Data In
tBUF
tLOW
SCL
tHIGH
tT:HL
tT:LH
90%
10%
90%
10%
SDA
Data Out
tHD:DAT
4
REV. 1.0.5 10/2/03
PRODUCT SPECIFICATION
Basic Operation
The FM75 temperature sensing circuitry continuously
produces an analog voltage that is proportional to the device
temperature. At regular intervals the FM75 converts the
analog voltage to a two’s complement digital value, which is
placed into the temperature register.
The FM75 has an SMBus compatible digital serial interface
which allows the user to access the data in the temperature
register at any time. In addition, the serial interface gives the
user easy access to all other FM75 registers to customize
operation of the device.
The FM75 temperature-to-digital conversion can have 9,
10, 11, or 12-bit resolution as selected by the user, providing
0.5°C, 0.25°C, 0.125°C, and 0.0625°C temperature
resolution, respectively. At power-up the default conversion
resolution is 9-bits. The conversion resolution is controlled
by the R0 and R1 bits in the Configuration Register.
Table 1 gives examples of the relationship between the
output digital data and the external temperature. The 9-bit,
10-bit, 11-bit and 12-bit columns in Table 1 indicate the
right-most bit in the output data stream that can contain
temperature information for each conversion accuracy.
Since the output digital data is in two’s-complement format,
the most significant bit of the temperature is the “sign” bit.
If the sign bit is a zero, the temperature is positive and if the
sign bit is a one, the temperature is negative.
The FM75 has a Shutdown Mode that reduces the operating
current of the FM75 to 150nA. This mode is controlled by
the SD bit in the configuration register.
Power Up Default Conditions
The FM75 always powers up in the following default state:
• Thermostat mode: Comparator Mode
• O.S. polarity: active low
• Fault tolerance: 1 fault (i.e., F0 = 0 and F1 = 0 in the
Configuration Register)
• TOS = 80°C
• THYST = 75°C
• Register pointer: 00 (Temperature Register)
• Conversion resolution: 9 bits (i.e., R0 = 0 and R1 = 0 in
the Configuration Register)
After power up these conditions can be reprogrammed via
the serial interface. Refer to the Serial Data Bus Operation
section for FM75 programming instructions.
Thermal Alarm Function
The FM75 thermal alarm function provides user programmable thermostat capability and allows the FM75 to function
as a stand alone thermostat without using the serial interface.
The Over-Limit Signal (O.S.) output is the alarm output. This
signal is an open drain output, and at power-up this pin is
configured with active-low polarity.
REV. 1.0.5 10/2/03
FM75
Table 1. Relationship Between Temperature and
Digital Output
Temperature
Digital Output
Sig
Number of
bits used
by
conversion
resolution
bit
9
bit
10
b it
11
b it
12
12-Bit Resolution
0000
11-Bit Resolution
All
Temperatures
0
0000
0
0
0000
0
0
0
0000
10 -Bit Resolution
9-Bit Resolution
Always
zero
+125°C
0
111
1101
0
0
0
0
0000
+100.0625°C
0
110
0100
0
0
0
1
0000
+50.125°C
0
011
0010
0
0
1
0
0000
+12.25°C
0
000
1100
0
1
0
0
0000
0°C
0
000
0000
0
0
0
0
0000
-20.5°C
1
110
1011
1
0
0
0
0000
-33.25° C
1
101
1110
1
1
0
0
0000
-45.0625°C
1
101
0010
1
1
1
1
0000
-55° C
1
100
1001
0
0
0
0
0000
The O.S. polarity is controlled by the POL bit in the
Configuration Register. The user-programmable upper
trip-point temperature for the thermal alarm is stored in
the TOS Register, and the user-programmable hysteresis temperature (i.e., the lower trip point) is stored in the THYST
Register.
The thermal alarm has two modes of operation: Comparator
Mode and Interrupt Mode. At power-up the default is
Comparator Mode. The alarm mode is controlled by the
CMP/INTR bit in the Configuration Register.
Fault Tolerance
For both Comparator and Interrupt modes, the alarm “fault
tolerance” setting plays a role in determining when the O.S.
output will be activated. Fault tolerance refers to the number
of consecutive times an error condition must be detected
before the user is notified. Higher fault tolerance settings can
help eliminate false alarms caused by noise in the system.
The alarm fault tolerance is controlled by bits F0 and F1 in
the Configuration Register. These bits can be used to set
the fault tolerance to 1, 2, 4 or 6 as shown in Table 4. At
power-up, these bits both default to 0 (fault tolerance = 1).
5
FM75
PRODUCT SPECIFICATION
Comparator Mode
Interrupt Mode
In Comparator Mode, each time a temperature-to-digital
(T-to-D) temperature conversion occurs, the new digital temperature is compared to the value stored in the TOS and
THYST registers. If a fault tolerance number of consecutive
temperature measurements are greater than the value stored
in the TOS register, the O.S. output will be activated.
For example, if bits F1 and F0 are equal to “10” (fault
tolerance = 4), four consecutive temperature measurements
must exceed TOS to activate the O.S. output. Once the O.S
output is active, it will remain active until the first time the
measured temperature drops below the temperature stored in
the THYST register. The operation of the alarm in Comparator
Mode with fault tolerance=2 is illustrated in Figure 1.
In Interrupt Mode the O.S. output will first become active
after a fault tolerance number of consecutive temperature
measurements exceed the value stored in the TOS register
(similar to Comparator Mode). Once O.S. is active, it can
only be cleared by a user read from any of the FM75
registers (Temperature, Configuration, TOS, or THYST) or by
putting the FM75 into Shutdown Mode (i.e., by setting the
shutdown bit in the Configuration Register to “1”). Once
cleared, the O.S. output can only be activated the next time
by a fault tolerance number of consecutive temperature
measurements that are lower than the value stored in THYST.
Again, once it is activated the O.S. output can only be
deactivated by a user read or shutdown. Thus, in Interrupt
Mode the activate/clear cycle for O.S. has the following
pattern: temperature > TOS, clear, temperature < THYST,
clear, temperature > TOS, clear, etc. The operation of the
alarm in Interrupt Mode with fault tolerance=2 is also
illustrated in Figure 1.
Temperature-to-Digital
Conversion
TOS
THYST
O.S. (Comparator Mode)
O.S. (Interrupt Mode)
For this example:
Fault Tolerance = 2
Output Polarity = Active Low
Read (or Shutdown)
Figure 1. Thermal Alarm Operation in Comparator and Interrupt Modes
6
REV. 1.0.5 10/2/03
PRODUCT SPECIFICATION
FM75
Registers
Command Register
The FM75 contains the following five registers:
The Command Register is a one-byte (8-bit) write-only
register. The data stored in the Command Register indicates
which of the other four registers (Temperature, Configuration, TOS, or THYST) the user intends to read from or
write to during an upcoming operation. In other words the
Command Register “points” to the selected register as shown
in Figure 2.
1.
Command Register
2.
Temperature Register
3.
Configuration Register
4.
Over-Limit-Signal Temperature Register (TOS)
5.
Hysteresis Temperature Register (THYST)
All of these registers can be accessed by the user via the
digital serial interface at any time (see Serial Interface
Operation for instructions). A detailed description of these
registers and their functions is provided in the following
paragraphs. A diagram of the register hierarchy is shown in
Figure 2.
The Command Register is illustrated in Figure 3. The P1 and
P0 bits of the Command Register determine which register is
to be accessed as shown in Table 2. The six MSBs of the
Command Register must always be zero. Writing a 1 into
any of these bits will cause the current operation to be
terminated.
The Command Register retains pointer information between
operations. Therefore, this register only needs to be updated
once for consecutive read operations from the same register.
All bits in the Command Register default to zero at
power-up.
SCL
SDA
Temperature Register
Serial Interface
Read/Write
Data
2-byte Read Only
Command Reg. = 00000000
Configuration Register
1-byte Read/Write
Command Reg. = 00000001
Command
(‘Pointer’)
Data
THYST Register
2-byte Read/Write
Command Reg. = 00000010
Command Register
1-byte Write Only
TOS Register
2-byte Read/Write
Command Reg. = 00000011
Figure 2. FM75 Register Hierarchy
MSB
0
LSB
0
0
0
0
0 P1 P0
Figure 3. Command Register Format
REV. 1.0.5 10/2/03
Table 2. Register Assignments for Command
Bits P1 and P2
Register
P1
P0
Temperature Register
0
0
Configuration Register
0
1
THYST Register
1
0
TOS Register
1
1
7
FM75
PRODUCT SPECIFICATION
Temperature Register
Configuration Register
The Temperature Register is a two-byte (16-bit) read-only
register. Digital temperatures from the T-to-D converter are
stored in the Temperature Register in two’s complement
format, and the contents of this register are updated at regular
intervals—i.e., each time the T-to-D conversion is finished.
The Configuration Register is a one-byte (8-bit) read/write
register (see Figure 5). This register allows the user to control
the FM75 Shutdown Mode as well as the following thermal
alarm features: polarity, operating mode, and fault tolerance.
The Configuration Register contains two bits that set the fault
tolerance trip point. The fault tolerance trip point is the number of consecutive times the internal circuit reads the temperature and finds the temperature outside the limits
programmed. The programmed limits are defined by the TOS
Register for the upper limit, and by the THYST Register for
the lower limit. Table 4 shows the relationship between F1
and F0 and the number of consecutive errors or “trips”
needed to activate the alarm. The Configuration Register also
contains the two bits that set the T-to-D conversion resolution
to 9, 10, 11, or 12 bits. Table 3 shows the relationship
between R1 and T0 and the conversion resolution. All bits in
the configuration register default to zero at power-up.
The user can read data from the Temperature Register at any
time. When a T-to-D conversion is completed, the new data is
loaded into a comparator buffer to evaluate fault conditions,
and will update the Temperature Register if a read cycle is
not ongoing. The FM75 is continuously evaluating fault
conditions regardless of read or write activity on the bus. If a
read is ongoing, the previous temperature will be read. The
readable temperature will be updated upon the completion of
the next T-to-D conversion that is not masked by a read
cycle.
The Temperature Register is illustrated in Figure 4. Depending on the resolution of the T-to-D conversion, the 9, 10,
11 or 12 MSBs of the register will contain temperature data.
All unused bits following the digital temperature will be
zero. The MSB position of the Temperature Register always
contains the sign bit for the digital temperature and bit 14
contains the temperature MSB. All bits in the Temperature
Register default to zero at power-up.
MSB 14
13
12
11
10
9
8
SB
T
T
T
T
T
T
TMSB
7
6
5
4
3
2
1
LSB
9-bit
LSB
10-bit
LSB
11-bit
LSB
12-bit
LSB
0
0
0
0
SB = Two’s complement sign bit
TMSB = Temperature MSB
T = Temperature data
9-bit LSB = Temperature LSB for 9-bit conversions
10-bit LSB = Temperature LSB for 10-bit conversions
11-bit LSB = Temperature LSB for 11-bit conversions
12-bit LSB = Temperature LSB for 12-bit conversions
Figure 4. Temperature Register Format
8
MSB
6
5
4
3
2
1
LSB
X R1 R0 F1 F0 POL CMP/
SD
INT
R1 = Resolution bit 1. (See Table 3)
R0 = Resolution bit 0. (See Table 3)
F1 = Fault tolerance bit 1. (See Table 4)
F0 = Fault tolerance bit 0. (See Table 4)
POL = O.S. output polarity. 0 = active low, 1 = active high.
CMP/INT = Thermostat mode. 0 = comparator mode,
1 = interrupt mode.
SD = Shutdown. 0 = normal operation, 1 = shutdown
mode.
Figure 5. Configuration Register Format
Table 3. Conversion Resolution Settings
A-to-D Conversion Resolution
R1
R0
9 Bits
0
0
10 Bits
0
1
11 Bits
1
0
12 Bits
1
1
Fault Tolerance
R1
R0
1
0
0
2
0
1
4
1
0
6
1
1
Table 4. Fault Tolerance Settings
REV. 1.0.5 10/2/03
PRODUCT SPECIFICATION
FM75
Over-Limit-Signal Temperature Register (TOS)
Hysteresis Temperature Register (THYST)
The TOS Register is a two-byte (16-bit) read/write register
that stores the user-programmable upper trip-point
temperature for the thermal alarm in two’s-complement
format. At power-up this register defaults to 80°C
(i.e., 0101 0000 0000 0000).
The THYST Register is a two-byte (16-bit) read/write
register that stores the user programmable lower trip-point
temperature for the thermal alarm in two’s-complement
format. At power-up this register defaults to 75°C (i.e., 0100
1011 0000 0000).
The format of the TOS register is identical to that of the
Temperature Register (see Figure 6). The 4 LSBs of the TOS
Register are hardwired to zero, so data written to these
register bits will be ignored. The MSB position of the TOS
Register contains the sign bit for the digital temperature and
bit 14 contains the temperature MSB.
The THYST register is illustrated in Figure 6. The format of
this register is the same as that of the Temperature Register.
The 4 LSBs of the THYST register are hardwired to zero, so
data written to these bits is ignored.
The resolution setting for the T-to-D conversion determines
how many bits of the THYST Register are used by the thermal
alarm. For example, for 9-bit conversions the hysteresis
temperature is defined by the 9 MSBs of the THYST Register,
and all remaining bits are “don’t cares.”
The resolution setting for the T-to-D conversion determines
how many bits of the TOS Register are used by the thermal
alarm. For example, for 9-bit conversions the trip-point
temperature is defined by the 9 MSBs of the TOS register,
and all remaining bits are “don’t cares.”
.
MSB 14
13
12
11
10
9
8
SB
T
T
T
T
T
T
TMSB
7
6
5
4
3
2
1
LSB
9-bit
LSB
10-bit
LSB
11-bit
LSB
12-bit
LSB
0
0
0
0
SB = Two’s complement sign bit
TMSB = Temperature MSB
T = Temperature data
9-bit LSB = Temperature LSB for 9-bit conversions
10-bit LSB = Temperature LSB for 10-bit conversions
11-bit LSB = Temperature LSB for 11-bit conversions
12-bit LSB = Temperature LSB for 12-bit conversions
Figure 6. THYST Register and TOS Register Format
REV. 1.0.5 10/2/03
9
FM75
PRODUCT SPECIFICATION
Serial Data Bus Operation
Slave Address
General Operation
Each slave device on the bus has a unique 7-bit address so
the master can identify which device is being read from or
written to.
Writing to and reading from the FM75 registers is accomplished via the SMBus-compatible two-wire serial interface.
SMBus protocol requires that one device on the bus initiates
and controls all read and write operations. This device is
called the “master” device. The master device also generates
the SCL signal which is the clock signal for all other devices
on the bus. All other devices on the bus are called “slave”
devices. The FM75 is a slave device. Both the master and
slave devices can send and receive data on the bus.
During SMBus operations, one data bit is transmitted per
clock cycle. All SMBus operations follow a repeating nine
clock-cycle pattern that consists of eight bits (one byte) of
transmitted data followed by an acknowledge (ACK) or not
acknowledge (NACK) from the receiving device. Note that
there are no unused clock cycles during any operation—
therefore there must be no breaks in the stream of data and
ACKs/NACKs during data transfers. Conversely having too
few clock cycles can lead to incorrect operation if an
inadvertent 8-bit read from a 16-bit register occurs.
For most operations, SMBus protocol requires the SDA line
to remain stable (unmoving) whenever SCL is high—i.e.,
transitions on the SDA line can only occur when SCL is low.
The exceptions to this rule are when the master device issues
a start or stop signal. Note that the slave device cannot issue
a start or stop condition.
The following are definitions for some general SMBus
terms:
Start Condition: This condition occurs when the SDA line
transitions from high to low while SCL is high. The master
device uses this condition to indicate that a data transfer is
about to begin.
Stop Condition: This condition occurs when the SDA line
transitions from low to high while SCL is high. The master
device uses this condition to signal the end of a data transfer.
Acknowledge and Not Acknowledge: When data is transferred to the slave device it sends an acknowledge (ACK)
after receiving every byte of data. A master device sends an
acknowledge (ACK) following only the first byte read from a
2-byte register. The receiving device sends an ACK by
pulling SDA low for one clock. Following the last byte,
a master device sends a “not acknowledge” (NACK)
followed by a stop condition. A NACK is indicated by
leaving SDA high during the clock after the last byte.
10
The FM75 address is as follows:
1
0
0
1 A2 A1 A0
The four MSBs of the FM75 address are hardwired to 1001.
The three LSBs are user configurable by tying the A0, A1
and A2 pins to either VDD or ground. This provides eight
different FM75 addresses, which allows up to eight FM75s
to be connected to the same bus.
Writing To and Reading From the FM75
All read and write operations must begin with a start signal
generated by the master device. After the start condition, the
master device must immediately send a slave address (7 bits)
followed by a read/write bit. If the slave address matches the
address of the FM75, the FM75 sends an ACK after
receiving the read/write bit by pulling the SDA line low
for one clock. See Figure 8 through Figure 13 for timing
diagrams for all FM75 operations.
Setting the Pointer
For all operations the pointer stored in the Command
Register must be pointing to the register (Temperature,
Configuration, TOS or THYST) that is going to be written to
or read from. To change the pointer value in the Command
Register, the read/write bit following the address must be 0.
This indicates that the master will now write new information into the Command Register.
After the FM75 sends an ACK in response to receiving the
address and read/write bit, the master device must transmit
an appropriate 8-bit pointer value as explained in the
Registers section of this data sheet. The FM75 will send an
ACK after receiving the new pointer data.
The pointer set operation is illustrated in Figure 8. Anytime a
pointer set is performed, it must be immediately followed by
a read or write operation. Note that the 6 MSBs of the
pointer value must be zero. If the 6 MSBs are not zero, the
FM75 will not send an ACK and will internally terminate the
operation. Also recall that the Command Register retains the
current pointer value between operations. Therefore, once a
register is being pointed to, subsequent read operations do
not require a pointer set cycle. Write operations always
require the pointer be reset.
REV. 1.0.5 10/2/03
PRODUCT SPECIFICATION
FM75
Reading
Writing
If the pointer is already pointing to the desired register, the
master can read from that register by setting the read/write
bit (following the slave address) to a 1. After sending an
ACK, the FM75 will begin transmitting data during the
following clock cycle. If the Configuration Register is
being read, the FM75 will transmit one byte of data (see
Figure 10). The master device should respond with a NACK
followed by a stop condition. If the Temperature, TOS or
THYST Register is being read, the FM75 will transmit two
bytes of data (see Figure 9). The master must respond to the
first byte of data with an ACK and to the second byte of data
with a NACK followed by a stop condition.
All writes must be proceeded by a pointer set as described
previously, even if the pointer is already pointing to the
desired register.
To read from a register other than the one currently being
pointed to by the Command Register, a pointer set to the
desired register must be done as described previously.
Immediately following the pointer set, the master must
perform a repeat start condition (see Figures 8 and 12) which
indicates to the FM75 that a new operation is about to occur.
It is important to note that if the repeat start condition does
not occur, the FM75 will assume that a write is taking place,
and the selected register will be overwritten by the upcoming
data on the data bus. After the start condition, the master
must again send the device address and read/write bit. This
time the read/write bit must be set to 1 to indicate a read. The
rest of the read cycle is the same as described in the previous
paragraph for reading from a preset pointer location.
Immediately following the pointer set, the master must
begin transmitting the data to be written. If the master is
writing to the Configuration Register, one byte of data must
be sent (see Figure 13). If the TOS or THYST Register is
being written to, the master must send two bytes of data
(see Figure 11). After transmitting each byte of data, the
master must release the SDA line for one clock to allow the
FM75 to acknowledge receiving the byte. The write
operation should be terminated by a stop signal from the
master.
Inadvertent 8-Bit Read from a 16-Bit
Register: A Caution
An inadvertent 8-bit read from a 16-bit register, with the
D7 bit low, can cause the FM75 to pause in a state where the
SDA line is pulled low by the output data and is incapable of
receiving either a stop or a start condition from the master.
The only way to remove the FM75 from this state is to
continue clocking for 9 cycles until SDA goes high, at which
time issuing a stop condition will reset the FM75. This
sequence can be seen in Figure 7 below.
Nine additional clock cycles to reset the FM75
SCL
SDA
1
Start
from
Master
0
0
1
A2 A1 A0 R/W A D7 D6 D5 D4 D3 D2 D1 D0 N
Address Byte
Ack
from
FM75
Most Significant
Data Byte
(from FM75)
D7
D6 D5 D4 D3 D2 D1 D0 N
No Ack
from
Master
Stop intended by
Master, but FM75
SDA line locked
low
Master must
detect error
condition on
FM75
No Ack Stop
from Condition
from
Master
Master
Figure 7. Inadvertent 8-Bit Read from 16-Bit Register Where D7 = 0 and Forces Output Low
REV. 1.0.5 10/2/03
11
FM75
PRODUCT SPECIFICATION
Note: This segment of this timing diagram is a generic
pointer set cycle which must be followed by either an
immediate read cycle or write cycle as shown in this
figure and in figures 10, 11, and 12.
....
SCL
SDA
S
1
0
0
A2
1
A1
A0
A
R/W
0
0
Ack
from
FM75
Address Byte
0
0
0
0
P1
....
A
P0
Ack
from
aTS75
Pointer Byte
.SCL
..
SDA
...
S
1
0
1
0
Repeat
Start
from
Master
A2
A1
A0 R/W
A
D7
Ack
from
FM75
Address Byte
D6
D5
D4
D3
D2
D1
D0
A
Ack
from
Master
Most Significant Data
Byte
(from FM75)
D7
D6
D5
D4
0
0
0
0
N
P
No Ack
from
Master
Least Significant Data Byte
(from FM75)
Figure 8. Pointer Set Followed by Immediate Read from A 2-byte Register (Temperature, TOS or THYST Register)
SCL
SDA
S
1
0
0
1
A2
A1
A0
A
R/W
D7
Ack
from
FM75
Address
Byte
D6
D5
D4
D3
D2
D1
D0
A
D7
Ack
from
Master
Most Significant Data
Byte
(from FM75)
D6
D5
D4
0
0
0
Least Significant Data
Byte
(from FM75)
0
N
P
No Ack
from
Master
Figure 9. Two-byte Read from Preset Pointer Location (Temperature, TOS or THYST Register)
SCL
SDA
S
1
0
0
1
A2
A1
Address Byte
A0
R/W
A
Ack
from
FM75
X
D6
D5
D4
D3
D2
D1
D0
Data Byte
(from FM75)
N
P
No Ack
from
Master
Figure 10. One-byte Read from Configuration Register with Preset Pointer
12
REV. 1.0.5 10/2/03
PRODUCT SPECIFICATION
FM75
....
SCL
1
S
SDA
0
0
A2
1
A1
A0
A
R/W
0
0
0
0
Ack
from
FM75
Address Byte
0
0
P1
P0
....
A
Ack
from
FM75
Pointer Byte
....
....
A
D7
D6
D5
D4
D3
D2
D1
D0
A
D7
Ack
from
FM75
Most Significant Data Byte
(from Master)
D6
D5
D4
0
0
0
0
P
A
Ack
from
FM75
Least Significant Data Byte
(from Master)
Figure 11. Pointer Set Followed by Immediate Write to A 2-byte Register (TOS or THYST Register)
SCL
SDA
S
1
0
0
1
A2
A1
A0
A
R/W
0
0
0
Ack
from
FM75
Address Byte
0
0
0
P1
A
P0
S
1
0
0
Ack
from Repeat Start
from
FM75
Master
Pointer Byte
A2
1
A1
A0
R/W
Address Byte
....
....
1
0
0
A2
1
A1
A0
R/W
A
X
D6
D5
Ack
from
FM75
Address Byte
(repeated here for
clarity, transmitted only
once in the actual sequence)
D4
D3
D2
D1
D0
N
P
No Ack
from
Master
Data Byte
(from FM75)
Figure 12. Pointer Set Followed by Immediate Read from Configuration Register
SCL
S
1
0
0
1
A2
A1
A0
R/W
A
0
0
0
0
0
0
P1
P0
A
X
D6 D5
D4
D3
D2
D1
D0
A
P
SDA
Address Byte
Ack
from
FM75
Pointer Byte
Ack
from
FM75
Data Byte
(from Master)
Ack
from
FM75
Figure 13. Pointer Set Followed by Immediate Write to the Configuration Register
REV. 1.0.5 10/2/03
13
FM75
PRODUCT SPECIFICATION
Mechanical Dimensions inches (millimeters) unless otherwise noted
0.189 - 0.197
(4.800 - 5.004)
8 7 6 5
0.228 - 0.244
(5.791 - 6.198)
1 2 3 4
Lead #1
IDENT
0.150 - 0.157
(3.810 - 3.988)
0.010 - 0.020
x 45°
(0.254 - 0.508)
0.0075 - 0.0098
(0.190 - 0.249)
Typ. All Leads
0.053 - 0.069
(1.346 - 1.753)
8° Max, Typ.
All leads
0.004 - 0.010
(0.102 - 0.254)
Seating
Plane
0.004
(0.102)
All lead tips
0.014
(0.356)
0.016 - 0.050
(0.406 - 1.270)
Typ. All Leads
0.014 - 0.020 Typ.
(0.356 - 0.508)
0.050
(1.270)
Typ
Molded Package, Small Outline, 0.15 Wide, 8-Lead (M8)
FS Package Number M08A
0.118 - 0.004
[3 ± 0.1]
8
–A–
SYMM
C
5
(0.189)
[4.8]
0.118 ± 0.004
[3 ± 0.1]
0.193 ± 0.004
[4.9 ± 0.1]
–B–
(0.040)
TYP
[1.02]
PIN 1
IDENT
(0.016)
TYP
[0.41]
1
4
LAND PATTERN RECOMMENDATION
(0.0256) TYP
[0.65]
R
0.030 - 0.037
[0.78 - 0.94]
(0.0256)
TYP
[0.65]
0.005
TYP
[0.13]
R
0.005
TYP
[0.13]
GAGE
PLANE
(0.010)
[0.23]
–C–
0.002 [0.05]
C
0.002 - 0.006
TYP
[0.06 - 0.15]
0.012 ± 0.002
TYP
[0.3 ± 0.05]
0.002 [0.05]
M
0.021 ± 0.005
[0.53 ± 0.12]
(0.033)
[0.84]
A S
B S
0.0375
[0.953]
0°–6° TYP
SEATING PLANE
0.007 ± 0.002
TYP
[0.18 ± 0.05]
8-Lead Molded Mini Small Outline Package (MSOP), JEDEC MO-187, 3.0mm Wide
FS Package Number MA08D
14
REV. 1.0.5 10/2/03
FM75
PRODUCT SPECIFICATION
Ordering Information
Part Number
Package
Temperature Range
Shipping
FM75M8x
8-Lead SOIC
-40°C to +125°C
2500 Units, Tape and Reel
FM75MM8x
8-Lead MSOP
-40°C to +125°C
3000 Units, Tape and Reel
DISCLAIMER
FAIRCHILD SEMICONDUCTOR RESERVES THE RIGHT TO MAKE CHANGES WITHOUT FURTHER NOTICE TO
ANY PRODUCTS HEREIN TO IMPROVE RELIABILITY, FUNCTION OR DESIGN. FAIRCHILD DOES NOT ASSUME
ANY LIABILITY ARISING OUT OF THE APPLICATION OR USE OF ANY PRODUCT OR CIRCUIT DESCRIBED HEREIN;
NEITHER DOES IT CONVEY ANY LICENSE UNDER ITS PATENT RIGHTS, NOR THE RIGHTS OF OTHERS.
LIFE SUPPORT POLICY
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES
OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE PRESIDENT OF FAIRCHILD SEMICONDUCTOR
CORPORATION. As used herein:
1. Life support devices or systems are devices or systems
which, (a) are intended for surgical implant into the body,
or (b) support or sustain life, and (c) whose failure to
perform when properly used in accordance with
instructions for use provided in the labeling, can be
reasonably expected to result in a significant injury of the
user.
2. A critical component in any component of a life support
device or system whose failure to perform can be
reasonably expected to cause the failure of the life support
device or system, or to affect its safety or effectiveness.
www.fairchildsemi.com