PERKINELMER PE300BUV

Imaging
D A T A S H E E T
Lighting
Telecom
Cermax® Xenon Arc Lamps
PE300BF and PE300BUV
CERMAX® XENON ARC LAMPS
Description
The Cermax® xenon arc lamp is an innovative lamp design in the specialty lighting industry. These lamps were introduced in the early 1980’s and are now
used in endoscopes in most major hospitals worldwide, in high brightness projection display systems, and for a wide variety of other high performance applications.
The PE300BF and PE300BUV Cermax®
lamps have an integrated ell parabolic
reflector, enabling high intensity, focused
output of ultraviolet, visible, and infrared
radiation. With their internal reflector and
rugged ceramic body construction,
Cermax® lamps are the safest and most
compact alternative to conventional quartz
xenon lamps. This makes them ideal for
applications that require a high degree of
illumination control.
Applications
Current-regulated or power-regulated
power supplies with output ripples of less
than 5% are recommended. Single shot
ignition pulses are advised because radio
frequency starters may damage the lamps
internal reflector.
In addition to lamps, PerkinElmer
Optoelectronics manufactures Cermax®
arc lamp power supplies, lamp holders,
OEM lighting systems, and fiber optic
light sources.
• Medical and industrial fiber optic illuminators
• Machine vision
• Infrared and visible spotlights/beacons
• Spectroscopy
• Microscopy
• UV Curing
• Video projection
.
www.perkinelmer.com/opto
PE300BF and PE300BUV
Operational Specifications
Physical Specifications
Description
Nominal
Range
Description
Specification
Power
300 watts
180-320 watts
Arc Gap
Current
21 amps (DC)
10-22 amps (DC)
.049 inch (1.24mm)
Parabolic Y2 = 0.5 X (inch)
Operating Voltage
Ignition Voltage
14 volts (DC)
13-16 volts (DC)
23 kilovolts (recommended minimum)
Temperature
150 Þ C (maximum)
Lifetime*
1000 hours (500 hour warranty)
132 grams
Window Diameter
1 inch (25.4 mm)
Focused Output at F/1.0 Lens
* End of lamp life is defined as 50% of initial output.
Output at Nominal Power
F= UV Filtered Output/ UV = UV Enhanced Output
Description
Reflector Geometry
Weight
Description
Visible Output
6mm aperture
3130 Lumens
29 watts
Total Output*
8mm aperture
1410 Lumens
14 watts
* Nominal values at 300 watts after 2 hour burn-in.
Peak Intensity
PE300BF
515x103 candelas
PE300BUV
460x103 candelas
Radiant Output*
50 watts
50 watts
UV Output*
2.6 watts
6.6 watts
IR Output*
28.8 watts
Visible Output*
Notes
1.
Lamp must not be operated with window facing upwards within
45º of vertical.
26.8 watts
2.
Seal temperature must not exceed 150º C.
5000 Lumens
4500 Lumens
3.
Color Temperature
5600 Kelvin
5050 Kelvin
Current/power regulated power supplies and PerkinElmer lamp
housing units are recommended.
Peak Instabilities
4%
4%
4.
Beam Geometry**
5º/6º/7º
5º/6º/7º
Lamp must be operated within recommended current and power
range. Over powering may lead to arc instability, hard starting
and premature aging.
5.
Hot mirror assembly is available for IR filtering.
6.
CERMAX lamps are much safer lamps to use than their quartz
xenon arc lamp equivalents. However, caution must be practiced
when operating lamps because they are under high pressure,
require high voltage, reach temperatures up to 200º C, and their
IR and UV radiation can cause skin burns and eye damage.
Read hazard sheet included with each lamp shipment.
*These values indicate total output in all directions.
Wavelengths = UV<390nm, IR>770nm, Visible 390nm to 770nm.
** Beam Geometry defined as half angle at 10% PTS after 01/100/1000 hours.
Dimensions
1.000
(25.4)
.250 (6.35)
1.000
(25.4)
Spectral Output
.250 (6.35)
.165
(4.19)
F
6-32 UNC 2B X .156 DP
2 x .40
(10.2)
.035
(.899)
1.667
(42.34)
1.298 (32.96)
.066 (1.52)
.125 (3.18)
RELATIVE OUTPUT
100
UV
F + HOT MIRROR
80
60
40
Y
X
20
Focal Point
Cathode
0
200
300
400
500
600
700
800
900
1000
1100
WAVELENGTH (NM)
Dimensions in parentheses are in millimeters.
PerkinElmer welcomes inquiries about special lamps. We would be pleased to discuss the requirements of your application and the feasibility of
designing a lamp specifically suited to your needs.
For more information e-mail us at [email protected] or visit our web site at www.perkinelmer.com/opto.
All values are nominal; specifications subject to change without notice.
USA:
PerkinElmer Optoelectronics
44370 Christy St.
Fremont, CA 94538
Phone: (510) 979-6500
Fax: (510) 687-1140
Toll Free: (800) 775-6786
Europe:
PerkinElmer Optoelectronics GmbH
Wenzel-Jaksch-Str. 31
65199 Wiesbaden
Germany
Phone: +49 611 492 0
Fax: +49 611 492 369
Asia:
PerkinElmer Optoelectronics
47 Ayer Rajah Crescent #06-12
Singapore 139947
Phone: +65 775 2022
Fax: +65 775 1008
.
DS-156 Rev C 1101
© 2000 PerkinElmer inc. All rights reserved.
www.perkinelmer.com/opto