CAR4000 Series 4000 Watt 24 / 48V Front End Features: ∎ ∎ ∎ ∎ ∎ ∎ ∎ Hot-swap N+1 Redundancy Single phase or Three phase Input Power Factor Correction Over Voltage, Over Current and Thermal Protection Visual LED Indicators 19” 3U High / 3-Bay Power Shelf International Safety Approvals FEATURES BENEFITS KEY MARKET SEGMENTS & APPLICATIONS No minimum load requirements Eliminates the need for preload on system backplace ∎ Distributed Power ∎ Blade Servers Modular design Easy insertion and extraction during hot swap ∎ Mid-end servers ∎ Network Equipment Single phase or three phase inputs One stop shopping, breadth of line ∎ Network Storage ∎ Test Equipment Ideal for Network Bus Applications ∎ Storage Area Networks Constant current characteristics SPECIFICATIONS Input Voltage Range Input Current Inrush Current Input Fuse Power Factor Efficiency Output Voltage & Current Adjust Range (Trim Pot) Over Voltage Protection OVP Protection Type CAR4010K1 CAR4010L1 Single Phase Input / 180-264 VAC / 47-63 Hz 25.5Amax 50Amax Single Fuse 30A 3AG 0.99 90% Typical @ 230 VAC +24 VDC @ 167A +48 VDC @ 83.3A 21.6~26.4 43.2~52.8 29.5~30.5 VDC 58.5~59.5 VDC Recycle AC Input to Reset CAR4030K1 CAR4030L1 Three Phase Input / 180-264 VAC / 47-63 Hz 15A per phase max. 50A max (per phase) Single Fuse per Phase 20A 3AG 0.95 90% Typical @ 230 VAC +24 VDC @ 167A +48 VDC @ 83.3A 21.6~26.4 43.2~52.8 29.5~30.5 VDC 58.5~59.5 VDC Standby Voltage Line Regulation Load Regulation Output Ripple & Noise Transient Response Start-up Time Hold-up Time Overshoot / Undershoot Temperature Coefficient Remote ON/OFF Power Fail Signal Over Current Protection Over Temperature Protection MTBF Output Power Good LED Indicators Operating Temperature Cooling EMI/EMC Dimensions Weight Safety Approvals 5VSB @ 500mA 0.5% using remote sense (5% on Stand-by Voltage) 0.5% using remote sense (5% on Stand-by Voltage) <1% (pk-pk) 3% max deviation 0.50ms recovery time for a 25% load change 2 seconds >20ms at low line 1% at turn ON/OFF 0.02% per °C Logic 1 (TTL High) or open enables unit (ON), Logic 0 (TTL Low) or short shuts unit down (OFF) Signal goes low (TTL Low) 2ms before loss output regulation 110-140% V1, 5VSB < 2.5A. Automatic recovery. Automatic shutdown with auto recovery. Thermal shutdown point @ 95°C 300,000 hrs per Bellcore standard TTL High = Power Good, TTL Low = Output out of limits DC Good: Green LED; Temperature OK: Green LED and AC Good: Amber LED 0°C to 50°C at rated output power. Supply derates linearly from 50°C to 65°C at 2.2% per °C Self contained ball bearing fan Meets EN61000-3-2, -3 CISPR22 and FCC Part 15 Class A, Bellcore GR-1089-CORE 14.12 x 5.00 x 5.00” / 333.2 x 127 x 127mm (handle extends additional 1.00” / 25.4mm from faceplate) 11.5 pounds / 5.23 kg UL1950, CSA 22.2 No. 650, TUV EN0950 & CE Mark rev 100506 www.lineagepower.com/oem Lineage Power Lineage Power Lineage Power (China) 3000 Skyline Dr. Mesquite, TX 75149 Phone: (972) 284-2000 2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Shanghai, 201401 China Phone: 021 6710 8910 CAR4000 Series 4000 Watt 24 / 48V Front End OUTLINE DRAWING: 14.12 Side & Bottom Views are of Bus Bar Output Connector Versions SIDE VIEW 5.00 1.04 1.00 1 .02 AIRFLOW 15.12 5.00 Latch BOTTOM VIEW 3.20 LEDs 3 2 1 8.00 0.16 0.822 1.79 0.25 REAR PANEL CONNECTIONS: CAR4030x1 CAR4010x1 1.25 V1 Rtn 1.20 0.641 V1 V1 RTN 1.25 Single Phase Input with Positronic CAR4030x1H Three Phase Input with Positronic V1 1.56 1.56 3.00 CAR4010x1H Three Phase Input with Bus Bar Single Phase Input with Bus Bar 2.99 0.84 0.65 15-PIN D-SUB CONNECTOR1 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 5 VSB 5VSB RTN MODULE PRESENT POWER GOOD ON/OFF I SHARE MOD-ENABLE OVP TEST POINT AC FAIL V PROGRAM + REMOTE SENSE CURRENT MONITOR TEMPERATURE OK - REMOTE SENSE NO CONNECTION THREE PHASE AC INPUT4 4 1 2 3 4 LINE 1 LINE 2 LINE 3 GROUND 0.59 2.44 Positronic Output Connector 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 V1 V1 V1 V1 V1 RETURN V1 RETURN V1 RETURN V1 RETURN V1 5VSB RTN MODULE PRESENT MODULE ENABLE CURRENT SHARE ON/OFF OVP V1 RETURN 5VSB POWER GOOD AC FAIL MARGIN 1 + SENSE TEMP OK MARGIN 2 - SENSE 0.98 3.095 SINGLE PHASE AC INPUT 3 1 2 3 4 5 6 GROUND LINE NEUTRAL GROUND LINE NEUTRAL MATING CONNECTORS 1) AMP 205205-2 Housing with 205090-1 Pins 2) Positronics PLC24F4BN0A1/AA Housing with FC114N2 pins 3) Positronics PLB06F000 Housing with FC114N2 pins 4) Positronics PLA04F8000 Housing with FC114N2 pins Output Bus Bars Mate with Elcon Part Number 538-17-00100 PART NUMBER DEFINITION GUIDE CAR 40 xx xx x xx - 1A CAR 40 xx xx x x Rev. x xx - 1A Series Blank=Non-Compliant 40=4000W Series Rev. Y0=5 of 6 Compliant Power Blank=Non-Compliant 40=4000W Z0=6 of 6 Compliant 10 = 1Ø Y0=5 of 6 Compliant Power RoHS Compliance 30 = 3Ø Z0=6 of 6 Compliant 10 = 1Ø Blank = Bus Bar Input Phase RoHS Compliance 30 = 3Ø H = Positornic K1=+24V Blank = Bus Bar Input Phase L1= +48V Output Connector H = Positronic (front-end only) K1=24V Output V Output Connector L1=48V Output V Blank = Positive Blank = Front End N = Negative T = Rectifier Polarity Type Examples: CAR4010L1-Z01A: 4000W / +48V Front End / Single Phase AC Input / 6 of 6 RoHS Compliant CAR4030L1H-Z01A: 4000W / +48V Front End / 3-Phase AC Input / Positronic Connector / 6 of 6 RoHS Compliant rev 100506 www.lineagepower.com/oem Lineage Power Lineage Power Lineage Power (China) 3000 Skyline Dr. Mesquite, TX 75149 Phone: (972) 284-2000 2841 Dow Avenue Tustin, CA 92780 USA Phone: (714) 544-6665 1353 Chenqiao Road, Shanghai Sengpu Industrial Park Shanghai, 201401 China Phone: 021 6710 8910