MA-COM CB-1046B-38

Catalog 1308242
Issued 3-03
P&B
CB series
CMOS IC Time Delay Relay
• Choice of timing modes
– Delay on operate
– Delay on release
– Interval on with or without control switch
• Knob adjustable
• 10A output relay with SPDT or DPDT contacts
• Various models time from 0.1 sec. to 100 min.
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Timing Modes
Contact Data @ 25°C
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
Arrangements: 2 Form C (DPDT), except 8-pin delay on release model
has 1 Form C (SPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC;
1/3 HP @ 120VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
INPUT
VOLTAGE
ON
OFF
N.O. RELAY ON
CONTACTS OFF
TIME
Delay on release – Input voltage must be applied continuously to operate
the internal relay. When the control switch is closed, the relay energizes.
When the control switch is opened, timing begins. When timing is
complete, the relay will de-energize. Time may be reset to zero during
timing by closing the control switch.
CONTROL
SWITCH
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
ON
OFF
N.O. RELAY ON
CONTACTS OFF
TIME
Interval on (without control switch) – The relay energizes and timing
begins when input voltage is applied. At the end of the time delay period
the relay will de-energize. Reset is accomplished by removing, then
reapplying, the input voltage.
INPUT
VOLTAGE
Initial Dielectric Strength
ON
OFF
Input Data @ 25°C
Voltage: 24 and 120VAC, and 12 and 24VDC.
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Input Voltages & Limits @ 25°C
N.O. RELAY ON
CONTACTS OFF
TIME
Interval on (with control switch) – Input voltage must be applied
continuously to operate the internal relay. The relay energizes and timing
begins when the external switch is closed. At the end of the time delay
period the relay will de-energize. Reset is accomplished by opening and
reclosing the control switch.
CONTROL
SWITCH
Maximum
Voltage
AC
24
120
12
24
20
105
11
20
28
130
13
32
DC
Environmental Data
Timing Ranges: From 0.1 to 1.0 sec. through 10 to 100 min.
Timing Adjustment: Knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types: –0, +30% of max. specified at high end of timing range;
min. specified, or less, at low end.
Fixed Types: ± 10%.
Res. Adj. Types: ± 10% at high end of timing range; min. specified, or less,
at low end.
Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%.
Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%.
Release Time: 60 ms, typ.; 100 ms, max.
Recycle Time: 60 ms, typ.; 100 ms, max.
Dimensions are shown for
Minimum
Voltage
TIME
Timing Specifications
1228 reference purposes only.
Nominal
Voltage
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
ON
OFF
N.O. RELAY ON
CONTACTS OFF
Voltage
Type
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Temperature Range: Storage: -55°C to +85°C.
Operating: -10°C to +55°C.
Mechanical Data
Termination: 8- or 11-pin octal style plug.
Enclosure: White plastic case. Knob adjustable types have dial scale for
reference only.
Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
27E892 (snap-on) screw terminal sockets.
Weight: 6 oz. (170g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03
P&B
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
Delay on Operate Models
Voltage
Time
24VAC
0.1 to 10 Sec.
1.8 to 180 Sec
120VAC
12VDC
Wiring Dia.
Part Number
Voltage
Time
Knob
1
CB-1041B-30
CB-1042B-30
24VAC
0.1 to 10 Sec.
1.8 to 180 Sec
0.1 to 1 Sec.
0.1 to 5 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
1 to 10 Min.
10 to 100 Min.
Knob
0.1 to 10 Sec.
Knob
0.1 to 1 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
24VDC
Delay on Release Models
Adjustment
CB-1001B-70
CB-1002B-70
CB-1003B-70
CB-1004B-70
CB-1005B-70
CB-1006B-70
CB-1007B-70
1
1
Knob
CB-1047D-20
120VAC
24VDC
0.1 to 10 Sec.
1.8 to 180 Sec.
Wiring Dia.
Part Number
Knob
3
CB-1045B-38
CB-1046B-38
3
5
3
3
CB-1021B-78
CB-1022B-78
CB-1023B-78
CB-1024B-78
Knob
3
CB-1038D-38
CB-1039D-38
Knob
Interval on Models
CB-1026D-30
CB-1028D-30
CB-1029D-30
CB-1030D-30
1
0.1 to 10 Sec.
0.1 to 10 Sec.
0.6 to 60 Sec.
1.8 to 180 Sec.
Adjustment
Voltage
Time
Adjustment
Wiring Dia.
Part Number
24VAC
0.1 to 10 Sec.
Knob
1
CB-1043B-39
120VAC
0.1 to 5 Sec.
0.1 to 10 Sec.
1 to 10 Min.
Knob
1
1
1
CB-1011B-79
CB-1014B-79
CB-1018B-79
Knob
1
CB-1034D-39
CB-1036D-39
24VDC
0.1 to 5 Sec.
1.8 to 180 Sec.
➛
Outline Dimensions
2.406 MAX.
(61.1)
➛
2.937 MAX.
(74.6)
➛
➛
➛
.56
(14.2)
➛
➛
.60
(15.2)
1.781 MAX.
(45.2)
➛
Wiring Diagrams - Bottom Views (pins numbered clockwise from keyway)
EXTERNAL
CONTROL
SWITCH*
EXTERNAL
CONTROL
SWITCH*
➛
➛
➛
➛
➛
➛
➛
➛
➛
➛
_
+
_
+
_
INPUT (DC POLARITY
INDICATED)**
CONTINUOUS
SUPPLY
INPUT
(DC POLARITY INDICATED)**
CONTINUOUS
SUPPLY
INPUT
(DC POLARITY INDICATED)**
Fig. 1
8 Pin
Fig. 3
11 Pin
Fig. 5
8 Pin
+
* If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A
“dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly.
** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
1229
Refer to inside back cover.