CF NEW DUAL POWER AUTOMOTIVE RELAY 22.5 .886 CF-RELAYS FEATURES 16.5 .650 Normally Normally Open Closed • 7 Amp Steady/30 Amp Inrush current capability • Simple footprint enables ease of PC board layout 16.5 .650 Coil 1 Common Open Space Coil 2 mm inch SPECIFICATIONS Contact Arrangement Contact material Characteristics 1 Form C×2 (H bridge) Silver alloy Initial contact resistance, max. (By voltage drop 6 V DC 1 A) Contact voltage drop, max. Nominal switching capacity Max. switching power Max. switching voltage Rating Max. make current 50 mΩ 0.2 V (at 20 A switching) N.O.: 20A 14 V DC N.C.: 10A 14 V DC 140 W 16 V DC 10 A (Continuous), 30 A (within 1 min.; coil applied voltage: 12 V, at 20°C) 30 A (2 minutes ), 20A (1 hour) Max. carrying current (coil applied voltage: 12 V, at 20°C) Mechanical (at 180 cpm) 106 resistive load Min.105 Expect 7 A 14 V DC, ed life Inrush 30 A 2×105 (min. Electrical (Motor load) ope.) 20 A 14 V DC Min.5×104 (Motor lock) Coil Nominal operating power 640 mW Max. operating speed (at rated load) Initial insulation resistance*1 Initial breakdown voltage*2 6 cpm Min. 100 mΩ (at 500 V DC) Between open contacts Between contacts and coil 1,000 Vrms for 1 min. 1,000 Vrms for 1 min. Operate time* (at nominal voltage) Release time (without diode)*3 (at nominal voltage) Functional*4 Shock resistance Destructive*5 3 Vibration resistance Conditions for operation, transport and storage*7 (Not freezing and condensing at low temperature) Unit weight Max. 10 ms Max. 10 ms Min. 100 m/s2 {10 G} Min. 1,000 m/s2 {100 G} Approx. 44.1 m/s2 {4.5 G}, 10 to 100 Hz Approx. 44.1 m/s2 {4.5 G}, 10 to 500 Hz –40°C to + 85°C –40°F to +185°F Functional*6 Destructive Ambient temp. Humidity 5 to 85%R.H. Standard type Approx. 15 g .529 oz Remarks * Specifications will vary with foreigh standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage" section *2 Detection current: 10mA *3 Excluding contact bounce time *4 Half-wave pulse of sine wave: 11ms; detection time: 10µs *5 Half-wave pulse of sine wave: 6ms *6 Detection time: 10µs *7 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61) TYPICAL APPLICATIONS ORDERING INFORMATION • Automotive: Power-window, power sunroof, etc. Ex. CF 2 – 12 V Contact arrangement Coil voltage(DC) 1 Form C × 2 12 V Standard packing: Carton: 35pcs.; Case: 700pcs. 367 CF TYPES AND COIL DATA (at 20°C 68°F) Part No. Nominal voltage, V DC Pick-up voltage, V DC (max.) Drop-out voltage, V DC (min.) Coil resistance, Ω (±10%) CF2-12V 12 7.2 1.0 225 Nominal operating current, mA (±10%) 53.3 Nominal operating Power, mW Usable voltage range, VDC 640 10 to 16 DIMENSIONS mm inch Recommended PC board pattern (6-4 dia.) (6-.157 dia.) Land diameter 16.5 .650 3.5 .138 0.3 .012 0.4 .016 1.1 .043 0.4 .016 8-1.5 dia.±0.1 8-.059 dia.±.004 3.81±0.1 .150±.004 7.62±0.1 10.16±0.1 .300±.004 .400±.004 5.08 .200 2.54 .100 5.08 .200 12.7 .500 16.5 .650 (0.8) (.031) 6.35±0.1 .250±.004 1.1 .043 1 .039 1.1 .043 5.08±0.1 .200±.004 2.54±0.1 .100±.004 (3) 5.08±0.1 (.118) .200±.004 12.7±0.1 .500±.004 0.3 .012 0.3 .012 1.1 .043 (R1.5) 1.27±0.1 .050±.004 1.2 max. .047 max. Schematic 3.81 .150 7.62 10.16 .300 .400 22.5 .886 N.O. COM1 N.C. COM2 Dimension: Max. 1mm .039 inch: 1 to 3mm .039 to .118 inch: Min. 3mm .118 inch: General tolerance ±0.1 ±.004 ±0.2 ±.008 ±0.3 ±.012 EXAMPLE OF CIRCUITS Forward/reverse control circuits of DC motor for power window N.O. COM 12 V DC N.C. SW A M N.O. COM N.C. SW B M : Power window motor 368 SW A OFF ON OFF SW B OFF OFF ON Motor Stop Forward Reverse CF REFERENCE DATA 1-(1). Coil temperature rise (at 23°C 73°F) 1-(2). Coil temperature rise (at 85°C 185°F) 2-(1). Electrical life test (Motor lock) Tested sample: CF2-12V, 6pcs. Contact carrying current: 0A, 7A, 10A, 15A, 20A Tested sample: CF2-12V, 6pcs. Contact carrying current: 10A, 15A, 20A Tested sample: CF2-12V, 3pcs. Load: 20A 14V DC Operating frequency: ON 1s, OFF 5s 10 100 100 Pick-up and drop-out voltage, V 20 A 80 15 A 10 A 7A 0A 70 60 50 40 80 Temperature rise, °C Temperature rise, °C 90 20A 15A 60 10A 40 30 20 Contact welding: 0 times Miscontact: 0 times 8 Pick-up voltage Max. X Min. 6 4 Drop-out voltage Max. X Min. 2 20 10 0 12 14 16 0 Coil applied voltage, V 12 14 0 16 0 5 No. of operations, ×104 Coil applied voltage, V 2-(2). Electrical life test (Motor free) Tested sample: CF2-12V, 3pcs. Load: 7A steady, Inrush 30A, 14V DC Operating frequency: ON 1s, OFF 5s Sample M Pick-up and drop-out voltage, V 10 Contact welding: 0 times Miscontact: 0 times 8 Pick-up voltage Max. X Min. 6 4 Drop-out voltage Max. X Min. 2 0 0 10 20 No. of operations, ×104 For Cautions for use, see Relay Technical Information (Page 48 to 76). 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, 369 Ltd. Go To Online Catalog