AC-DC 660 - 1680 Watts xppower.com CPB1K/1K5 Series • Universal PFC Input • Low Profile (61 mm) • Wide Output Voltage Adjustment • Remote On/Off • Power Good Signal • Remote Sense • Peak Current Available Specification Input Input Voltage Input Frequency Input Current Inrush Current Power Factor Earth Leakage Current General • • • • • • 85-264 VAC (120-370 VDC) 47-63 Hz 19 A at 115 VAC 40 A at 230 VAC 0.98/0.95 at 115/230 VAC 1.5 mA max at 230 VAC/60Hz Output Output Voltage Output Voltage Trim Minimum Load Start Up Time Hold Up Time Drift Line Regulation Load Regulation Ripple & Noise Overvoltage Protection Overtemperature Protection Overload Protection Temperature Coefficient Remote Sense Remote On/Off • • • • • • • • • • • See tables See tables No minimum load required 400 ms typical at 230 VAC, 100% load 20 ms typical at 100% load ±0.4% max ±0.5% max ±1.0% max 0-100% load ±1.0% pk-pk, 20MHz BW 110-130% Vnom, recycle input to reset Operates in the event of fan failure or if the operating temperature / derating criteria is exceeded • Operates at 105% of rated current (101% of pk rating), <5 s auto recovery, >5 s recycle input to reset • ±1.25% max -20 ºC to +50 ºC • Compensates for up to 0.3 V drop max if not required, sense teminals must be connected locally i.e +S to +M and -S to -M on CN1 • 12 V 3 mA applied between RCG & RC2 will inhibit the output of the unit and the fan Efficiency Isolation Switching Frequency • See tables • 3000 VAC Input to Output 2000 VAC Input to Ground 500 VAC Output to Ground • 130 kHz PFC, 200 kHz PWM Environmental Operating Temperature • -20 ºC to +70 ºC, derate linearly from +50 ºC to 50% at +70 ºC Relative Humidity • 20-90% non-condensing Storage Temperature • -20 ºC to +75 ºC Shock • 20 G 11 ms, once each x, y and z axis Vibration • 2 G, 10 Hz to 55 kHz, 3 min periods for 60 min along each x, y and z axis EMC & Safety Emissions ESD Immunity Radiated Immunity EFT/Burst Surge Safety Approvals • EN55022, level B conducted EN55022, level A radiated • EN61000-4-2, level 2 contact, level 3 air • EN61000-4-3, level 3 • EN61000-4-4, level 3 • EN61000-4-5, level 3 line to line, level 4 line to ground • EN60950, UL60950, cUL (CSA 60950) Current Input Voltage Regulation Ripple & Noise(2) Efficiency(3) Model Number 40 mV 120 mV 76% CPB1KPS3V3 40 mV 120 mV 81% CPB1KPS05 36 mV 60 mV 150 mV 83% CPB1KPS7V5 - 48 mV 100 mV 150 mV 84% CPB1KPS12 - 60 mV 120 mV 150 mV 84% CPB1KPS15 96 mV 150 mV 150 mV 86% CPB1KPS24 - 114 mV 150 mV 200 mV 86% CPB1KPS36 - 192 mV 300 mV 200 mV 86% CPB1KPS48 Max Peak Line Load 3.3 V (2.64 - 3.96) 200 A - 20 mV 5.0 V (3.96 - 6.00) 200 A - 20 mV 7.5 V (5.25 - 8.25) 134 A - 12 V (8.25 - 13.20) 88 A 15 V (10.50 - 16.50) 70 A 24 V (16.50 - 26.40) 44 A 36 V (25.20 - 39.60) 29 A 48 V (38.40 - 56.00) 22 A 51 A (1) Notes 1. Peak current duration 10 s max with duty cycle ≤ 35% 170-264 VAC only. 2. Measured over a 20 MHz bandwidth from 0 ºC to +50 ºC. 3. Measured at nominal 230 VAC input and 100% load. Mechanical Details Input terminal cover 110 ±0.5 150 H V .A D J CN 2 C N1 C N3 Output terminal(+ ) 2.5 Output terminal(- ) ( 24) Output voltage adjustable potentiometer LED 51.25 165 ±0.5 240 29 (35) Notes: 1. Tolerance: ±1. 2. Weight: 2.2 Kg. 3. Dimensions in mm. 6max 8-M4 Mounting Hole (Both sides) 7 13 165±0.5 29 AIR FLOW 11.5 ( 18) ( 25) 38±0.5 2-M4 2-º 9 61 10 FG 79 AC ( N) CN3 CN2 CN1 25max 20 13 9 ( 7.5) AC ( L) AC(L) AC(N) FG( ) 4-M4 Mounting Hole (Bottom sides) Name plate 104.75 M4 15.85 Peak Current CN1/CN2 PIN CONNECTIONS Function +M + Output Voltage Monitoring +S + Remote Sensing -M - Output Voltage Monitoring -S - Remote Sensing VB Voltage Balance CB Current Balance TRM Adjustment of Output Voltage - Remote Sensing -S RC2 Remote On/Off RCG Remote On/Off Ground Pin 1 2 3 4 5 6 7 8 CN3 PIN CONNECTIONS Function -S - Remote Sensing -S - Remote Sensing AUX Auxiliary Output (12V/0.1A) RC1 Remote On/Off AUXG AUX Ground N.C No Connection PG Power Good Signal PGG Power Good Ground Peak Current Conditions: • • • • l 170-264 VAC t1 ≤ 10 s lp ≤ Rated peak current lave ≤ Rated current • Duty = t1 t1 + t2 x 100 [%] ≤ 35% p (Peak Current) Output Current (A) Pin 1 2 3 4 5 6 7 8 9 10 l ave (Average Current) t1 t2 Mating Connector & Terminal - CN1, CN2 & CN3 Connector CN1 CN2 CN3 Mating Connector S10B-PHDSS PHDR-10VS S8B-PHDSS PHDR-8VS Terminal Reel SPHD-002T-P0.5 Loose BPHD-001T-P0.5 BPHD-002T-P0.5 Manufacturer J.S.T AC-DC CPB1K Models and Ratings Current Input Voltage Regulation Ripple & Noise(3) Efficiency(4) Model Number(3) 40 mV 120 mV 75% CPB1K5PS3V3 40 mV 120 mV 81% CPB1K5PS05 36 mV 60 mV 150 mV 81% CPB1K5PS7V5 - 48 mV 100 mV 150 mV 82% CPB1K5PS12 - 60 mV 120 mV 150 mV 86% CPB1K5PS15 Max Peak Line Load 3.3 V (2.64 - 3.96) 300 A - 20 mV 5.0 V (3.96 - 6.00) 300 A - 20 mV 7.5 V (5.25 - 8.25) 200 A - 12 V (8.25 - 13.20) 125 A 15 V (10.50 - 16.50) 100 A 24 V (16.50 - 26.40) 70 A (1) 105 A (2) 96 mV 150 mV 150 mV 86% CPB1K5PS24 36 V (25.20 - 39.60) 47 A (1) 70 A (2) 114 mV 150 mV 200 mV 86% CPB1K5PS36 48 V (38.40 - 56.00) 35 A 192 mV 300 mV 200 mV 86% CPB1K5PS48 (1) - Notes 1. At low input voltage i.e. 115 V nom derate to 65 A, 42 A and 32 A. 2. Peak current duration 10 s max with duty cycle ≤ 35% 170-264 VAC only. 3. Measured over a 20 MHz bandwidth from 0 ºC to +50 ºC. 4. Measured at nominal 230 VAC input and 100% load. ( 7.5) 8-M4 Mounting Hole (Both sides) 25max CN1 178 V.ADJ CN2 CN3 152.4 ±0.5 FG 132 NC ) CN1 CN2 CN3 Input terminal cover 107 AC ( N) FG( AC ( L) AC(L) AC(N) NC Name plate 13 9 M4 15.85 12.8 Mechanical Details 10 4 LED Output terminal(-) ( 24) Output voltage adjustable potentiometer Output terminal(+) 51.25 Notes: 1. Tolerance: ±1. 2. Weight: 3.4 Kg. 3. Dimensions in mm. 19 (45) 171.5 ±0.5 268 6max 8-M4 Mounting Hole (Both sides) 4-M4 2-º 9 CN1/CN2 PIN CONNECTIONS Function +M + Output Voltage Monitoring +S + Remote Sensing -M - Output Voltage Monitoring -S - Remote Sensing VB Voltage Balance CB Current Balance TRM Adjustment of Output Voltage - Remote Sensing -S RC2 Remote On/Off RCG Remote On/Off Ground Output Voltage Adjustment Peak Current Conditions: 60-110% of the rated output voltage is achieved by: • • • • 1. Using on-board potentiometer 2. Applying a voltage externally between TRM & -S on CN1 or CN2 3. Connecting a resistor externally between TRM & -S on CN1 or CN2 The external voltage level is calculated below and should not be less than -0.7 V or more than 3.0 V. External Trim Voltage = Pin 1 2 3 4 5 6 7 8 CN3 PIN CONNECTIONS Function -S - Remote Sensing -S - Remote Sensing AUX Auxiliary Output (12V/0.1A) RC1 Remote On/Off AUXG AUX Ground N.C No Connection PG Power Good Signal PGG Power Good Ground 04 AUG 05 171.5 ±0.5 Required Vout x 2.5 Vnom 170-264 VAC t1 ≤ 10 s lp ≤ Rated peak current lave ≤ Rated current • Duty = x 100 [%] ≤ 35% t1 t1 + t2 Peak Current l p (Peak Current) Output Current (A) Pin 1 2 3 4 5 6 7 8 9 10 19 11.5 10 15 61 38 ±0.5 AIR FLOW ( 18) ( 25) AC-DC CPB1K5 Models and Ratings l ave (Average Current) t1 t2 Mating Connector & Terminal - CN1, CN2 & CN3 Connector CN1 CN2 CN3 Mating Connector S10B-PHDSS PHDR-10VS S8B-PHDSS PHDR-8VS Terminal Reel SPHD-002T-P0.5 Loose BPHD-001T-P0.5 BPHD-002T-P0.5 Manufacturer J.S.T