XPPOWER CPF5US12

AC-DC PCB Mount
5-10 Watts
THE XPERTS IN POWER
CPF Series
•
PCB Mounting
•
Low Cost
•
Universal Input
•
Small Footprint
•
Rugged Design
•
Surface Mount Technology
•
Accessory Mounting Boards
Specification
Input
General
Input Voltage
Input Frequency
Input Current
•
•
•
85-264 VAC (110-370 VDC)
47-440 Hz
0.3 A max (110 VAC Io = 100%)
Inrush Current
•
15 A typical (110 VAC Io = 100%),
30 A typical (230 VAC = Io 100%)
Switching Frequency •
Earth Leakage
Current
•
at cold start
0.5 mA max at 230 VAC 60 Hz
Environmental
Output
Output Voltage
Minimum Load
Start-Up Delay
Hold-Up Time
Initial Set Accuracy
Drift
Line Regulation
Load Regulation
Ripple & Noise
Overvoltage
Protection
Overcurrent
Protection
Temperature
Coefficient
•
•
•
•
•
•
•
•
•
•
•
•
See Table
No minimum load required
700 ms max at rated input & load
10 ms min
-3%, +6% max
0.6% max
See Table
See Table
260 mV pk-pk max, 20 MHz bandwidth
Operates >115% Vnom, clamps by
zener diode
Operates >125% of rating,
auto recovery
0.04%/°C
Efficiency
Isolation
•
•
Operating
Temperature
Storage
Temperature
Humidity
Shock
Vibration
•
•
See Table
3000 VAC Input to Output
2000 VAC Input to Ground
500 VAC Output to Ground
100 kHz typical
-10 °C to +55 °C (derate linearly above
+55 °C to 25% at +70 °C)
-20 °C to +75 °C
•
•
•
20-95% RH non-condensing
20 G 11 ms once each X, Y & Z axis
2 G 10-55 Hz 3 min period for 60 mins
along X, Y & Z axis
Emissions
•
ESD Susceptibility
•
Radiated
Susceptibility
EFT/Burst
Surge
•
EN55022 Level B conducted
EN55022 Level B radiated
EN61000-4-2 Level 3 Air,
Level 2 Contact
EN61000-4-3 Level 3
•
•
Safety Approvals
•
EMC & Safety
EN61000-4-4 Level 3
EN61000-4-5 Level 3 line to line,
Level 4 line to ground
UL1950, C-UL, EN60950, VDE 0160
•
•
www.xpplc.com
[email protected]
OUTPUT VOLTAGE & CURRENT RATINGS
Output
Voltage
3.3 V
5.0 V
12.0 V
15.0 V
24.0 V
3.3 V
5.0 V
12.0 V
15.0 V
24.0 V
Output
Current
1.00 A
1.00 A
0.45 A
0.35 A
0.22 A
2.00 A
2.00 A
0.90 A
0.70 A
0.45 A
Peak
(1)
Current
1.20 A
1.20 A
0.54 A
0.42 A
0.27 A
2.40 A
2.04 A
1.08 A
0.84 A
0.54 A
Efficiency
Typical
68%
77%
78%
77%
81%
65%
74%
78%
81%
81%
CPF
Line
(2)
Regulation
20 mV
20 mV
48 mV
60 mV
96 mV
20 mV
20 mV
48 mV
60 mV
96 mV
Load
(3)
Regulation
40 mV
40 mV
100 mV
120 mV
150 mV
40 mV
40 mV
100 mV
120 mV
150 mV
Model
Number
CPF5US03
CPF5US05
CPF5US12
CPF5US15
CPF5US24
CPF10US03
CPF10US05
CPF10US12
CPF10US15
CPF10US24
Notes
1. Peak rating duration ≤10 seconds with a max duty cycle of 35%..
2. Measured low line to high line.
3. Measured no load to full load.
•
Mechanical Details
5 W MODEL
10 W MODEL
Dimensions in inches (mm).
Weight 30g
CPF Board
Weight 40g
The CPF board is designed to accept any of the CPF Series models.
Order CPFBOARD-M for molex connectors or CPFBOARD-T for screw terminals.
CPFBOARD-M
CPFBOARD-T
Max height
17.5 mm
Mounting hole M3 clearance.
Mating Housing Molex 09-91-0500
Crimp Pins Molex 15-04-0219
www.xpplc.com
Mounting hole M3 clearance.
All connections screw terminals 10 mm pitch
[email protected]