AGERE 1340CNPC

Data Sheet
January 2000
1340-Type Lightwave Receiver
■
CMOS (TTL) link-status flag output
■
Operation at 1.3 µm or 1.55 µm wavelengths
■
Operating case temperature range of
–40 °C to +85 °C
Applications
Operating at 1.1 µm through 1.6 µm wavelengths and at
155 Mbits/s, 622 Mbits/s, or 1.25 Gbits/s, the versatile
1340-Type Receiver is manufactured in a 20-pin, plastic DIP
with a multimode fiber pigtail.
Features
■
Backward compatible with 1310 receiver family
■
Space-saving, self-contained, 20-pin plastic DIP
■
Silicon-based ICs
■
Single 5 V power supply operation including photocurrent monitor capability
■
Exceeds all SONET (GR-253-CORE) and ITU-T
G.958 jitter requirements
■
Wide dynamic range
■
Qualified to meet the intent of Telcordia Technologies * reliability practices
■
Operates at data rates of 155 Mbits/s,
622 Mbits/s, or 1.25 Gbits/s
■
Positive ECL (PECL) data outputs
■
Telecommunications:
— Inter- and intraoffice SONET/ITU-T SDH
— Subscriber loop
— Metropolitan area networks
■
High-speed data communications
Description
The 1340-Type receiver is designed for use in transmission systems or medium- to high-speed data
communications applications at data rates up to
1.25 Gbits/s. Compact packaging, along with wide
dynamic range, makes these receivers ideal for both
telecommunications and data communications applications.
The following three versions of the receiver are available:
■
SONET/SDH compliant with OC-3/STM-1
■
SONET/SDH compliant with OC-12/STM-4
■
1.25 Gbits for data applications.
* Telcordia Technologies is a trademark of Telcordia Technologies,
Inc.
Data Sheet
January 2000
1340-Type Lightwave Receiver
Description (continued)
The SONET/SDH versions of the receiver are fully
compliant with the latest issue of Telcordia Technologies GR-253- CORE and the most recent issues of ITU
recommendations G.957 and G.958. The 1340-Type
receiver requires only a single 5 V power supply for
operation. All versions of the receiver are characterized
for operation over the case operating range of –40 °C
to +85 °C at the appropriate data rate for each version.
Manufactured in a 20-pin DIP, the receivers use a planar, rear illuminated InGaAs PIN photodetector that
allows these receivers to be used at wavelengths from
1.1 µm to 1.6 µm. The photocurrent output of the PIN
detector is amplified and converted to a voltage by a
silicon amplifier. A silicon quantizer provides additional
signal amplification, data threshold detection, and
PECL data outputs. The incoming optical signal is coupled into the receiver through a 62.5 µm core multimode fiber pigtail. The outer jacket diameter of the
pigtail is 900 µm. The receiver can be ordered with the
pigtail terminated in an FC/PC, SC, or ST ® optical connector. Other connectors are available on special order.
See your Agere account representative for ordering
conditions and information.
The receiver has differential PECL data outputs and,
depending on the version selected, either differential
PECL link status flag or complementary CMOS link
status flag outputs. The link status flag outputs indicate
the presence or absence of a minimum acceptable
level of optical input signal.
VCC
FLAG
FLAG
FILTER
InGaAs
PIN
GaAs
PREAMPLIFIER
Si
COMPARATOR
FILTER
VPIN
DATA
DATA
1-414(F)
Figure 1. Block Diagram
2
Agere Systems Inc.
Data Sheet
January 2000
Description (continued)
To help ensure high product reliability and customer
satisfaction, Agere is committed to an intensive quality
program that starts in the design phase and proceeds
through the manufacturing and shipping process. Optoelectronics subsystems are qualified to Agere internal
standards using MIL-STD-883 test methods and procedures and sampling techniques consistent with Telcordia Technologies requirements. The 1340 receiver
qualification program meets the intent of Telcordia
Technologies TR-NWT-000468 andTA-TSY-000983.
Application Information
The 1340 receiver is a highly sensitive fiber-optic
receiver. Although the data outputs are digital logic levels (PECL), the device should be thought of as an analog component. When laying out the printed-wiring
board (PWB), the 1340 receiver should be given the
same type of consideration one would give to a sensitive analog component.
At a minimum, a double-sided printed-wiring board with
a large component-side ground plane beneath the
receiver must be used. In applications that include
many other high-speed devices, a multilayer PWB is
highly recommended. This permits the placement of
power and ground connections on separate layers,
which helps minimize the coupling of unwanted signal
noise into the power supplies of the receiver.
Layout Considerations
A fiber-optic receiver employs a very high-gain, widebandwidth transimpedance amplifier. The amplifier
detects and amplifies signals that are only tens of nA in
amplitude. Any unwanted signal currents that couple
into the receiver circuitry cause a decrease in the
receiver’s sensitivity and can also degrade the performance of the receiver’s loss of signal (FLAG) circuit.
To minimize the coupling of unwanted noise into the
receiver, route high-level, high-speed signals such as
transmitter inputs and clock lines as far away as possible from the receiver pins. If this is not possible, then
the PWB layout engineer should consider interleaving
the receiver signal and flag traces with ground traces in
order to provide the required isolation.
Agere Systems Inc.
1340-Type Lightwave Receiver
Noise that couples into the receiver through the power
supply pins can also degrade device performance. The
application schematics, Figures 3—5, show recommended power supply filtering that helps minimize
noise coupling into the receiver. The bypass capacitors
should be high-quality ceramic devices rated for RF
applications. They should be surface-mount components placed as close as possible to the receiver power
supply pins. The ferrite bead should have as high an
impedance as possible in the frequency range that is
most likely to cause problems. This will vary for each
application and is dependent on the signaling frequencies present on the application circuit card. Surfacemount, high-impedance beads are available from several manufacturers.
Data and Flag Outputs
The data outputs of the 1340 receiver are driven by
open-emitter NPN transistors which have an output
impedance of approximately 7 Ω. Each output can provide approximately 50 mA maximum output current.
Due to the high switching speeds of ECL outputs,
transmission line design must be used to interconnect
components. To ensure optimum signal fidelity, both
data outputs (DATA and DATA) should be terminated
identically. The signal lines connecting the data outputs
to the next device should be equal in length and should
have matched impedances.
Controlled impedance stripline or microstrip construction must be used to preserve the quality of the signal
into the next component and to minimize reflections
back into the receiver. Excessive ringing due to reflections caused by improperly terminated signal lines
makes it difficult for the component receiving these signals to decipher the proper logic levels and may cause
transitions to occur where none were intended. Also, by
minimizing high frequency ringing due to reflections
caused by improperly designed and terminated signal
lines, possible EMI problems can be avoided. The
applications sections in the Signetics*ECL 10K/100K
Data Manual or the National Semiconductor † ECL
Logic Databook and Design Guide provide excellent
design information on ECL interfacing.
* Signetics is a registered trademark of Signetics Corp.
† National Semiconductor is a registered trademark of National
Semiconductor Corporation.
3
Data Sheet
January 2000
1340-Type Lightwave Receiver
Data and Flag Outputs (continued)
The FLAG and FLAG outputs of the OC-3/STM-1
155 Mbits/s version of the 1340 receiver are PECL
logic levels driven by open emitter transistors with the
same characteristics as the data outputs. These outputs must be properly terminated in order to obtain the
correct logic levels. Since the FLAG function is basically a dc switch that indicates the loss of optical input
signal, it can be interfaced to much slower TTL or
CMOS logic circuits.
The circuit shown in Figure 2 provides one example of
how to create a TTL logic output from the PECL FLAG
output signal. The outputs of the LT1016 are TTL-compatible and provide both true and inverted logic levels.
The Q output of this circuit will be a TTL high (>2.5 V)
when the 1340 is receiving an optical signal greater
than the FLAG switching threshold and will be a TTL
low (<0.4 V) whenever the optical signal is absent or is
below the FLAG switching threshold. The FLAG and
FLAG outputs of the OC-12/STM-4 and 1.25 Gbits/s
receivers are 5 V TTL logic level compatible. The FLAG
output is provided directly by the comparator IC. However, the FLAG output is derived from the FLAG output
through an inverter. Excessive loading of the FLAG output can cause the FLAG output to malfunction.
+5 V
+5 V
11
1340
RX
12
+
Q
FLAG
TTL (TRUE)
LT1016*
FLAG
14
–
10 k•
Q
TTL (INVERTED)
10 k•
1-800(C).a
* Part available from Linear Technology Corporation of Milpitas, CA 95035.
Figure 2. Converting PECL FLAG Outputs to TTL
4
Agere Systems Inc.
Data Sheet
January 2000
1340-Type Lightwave Receiver
A single 50 Ω resistor terminated to (VCC – 2 V) could
also be used, but this requires a second power supply.
Other methods of terminating ECL-type outputs are
discussed in the references previously mentioned.
Pin 10
Pin 10 on the 1340-Type receiver is a not internally
connected (NIC) pin. This definition allows the 1340 to
be used in most customer 20-pin receiver module
applications. Customer’s printed-wiring boards that are
designed with ground, +5V, –5V, or no connection to
this pin are all acceptable options. For those applications that require monitoring the photocurrent of the
PIN photodetector for power monitoring purposes,
there are versions of the 1340 that require +5 V or –5 V
applied to Pin 10. CheckTables 4 and 5 for ordering
information.
Figure 5 shows an example of a circuit that can be
used to interface the PECL outputs of the 1340 receiver
with a device which requires true, negative voltage ECL
inputs. The 100314 is an ECL line receiver and is
shown here only as an example to demonstrate this
coupling procedure. The DATA lines are terminated in a
50 Ω equivalent impedance but are ac-coupled to the
100314. The capacitive coupling isolates and permits
level shifting of the positiveDATA outputs of the
receiver to the proper negative level required by the
inputs of the 100314. The V BB output of the 100314
provides the reference voltage required to center the
voltage swing of theDATA signals around the input
switching threshold of the 100314. The Thévenin
equivalent of the 166 Ω and 250 Ω resistor pair is
100 Ω, which, in parallel with the 100 Ω resistor connected to VBB, results in a 50 Ω equivalent impedance
for the load on each of the data lines. Alternatively, if
there is no VBB reference available, a second pair of
166 Ω/250 Ω resistor networks could be used on the
data lines on the 100314 side of the coupling capacitor.
Recommended User Interface
The 1340 receiver is designed to be operated from a
5 V power supply and provides raised or pseudo-ECL
(PECL) data outputs. Figures 3 and 4 show two possible application circuits for the 1340 receiver. Figure 3
represents an application for the version with PECL
FLAG outputs while Figure 4 shows a possible application for the version with the TTL-compatible FLAG
outputs.
In both instances, the DATA outputs are terminated with
a Thévenin equivalent circuit, which provides the equivalent of a 50 Ω load terminated to (VCC – 2 V).
+5.0 V
2.2 µF †
0.1 µF
0.1 µF
82 •
FERRITE
BEAD ‡
0.1 µF
11
82 •
82 •
12
FLAG*
0.1 µF
82 •
9
DATA †
1340
14
7
DATA †
FLAG*
124 •
124 •
124 •
124 •
* 50 Ω to (VCC – 2) V.
† DATA and DATA are 50 Ω impedance transmission lines; both lines can be ac- or dc-coupled into the next device.
‡ Fair-Rite Products Corporation part number 2743037447 or equivalent.
1-500(C).d
Note: All unused outputs must be terminated as shown. All resistors are 1/8 W, thin-film, ceramic chips. All capacitors are
25 Vdc, ceramic X7R, or equivalent.
Figure 3. Interfacing to the 155 Mbits/s 1340 Receiver
Agere Systems Inc.
5
Data Sheet
January 2000
1340-Type Lightwave Receiver
Recommended User Interfaces (continued)
+5.0 V
2.2 µF
†
FERRITE
BEAD
‡
0.1 µF
0.1 µF
0.1 µF
11
82 •
12
FLAG*
82 •
9
1340
7
14
FLAG*
DATA
†
DATA
†
124 •
124 •
* TTL (CMOS) compatible level.
† DATA and DATA are 50 Ω impedance transmission lines; both lines can be ac- or dc-coupled into the next device.
‡ Fair-Rite Products Corporation part number 2743037447 or equivalent.
1-500(C).c
Figure 4. Interfacing to the 622 Mbits/s and 1.25 Gbits/s 1340 Receivers
V EE
+5 V
2.2 µF †
FERRITE
BEAD ‡
0.1 µF
0.1 µF
0.1 µF
0.1 µF
0.1 µF
0.1 µF
11
82 •
166 •
82 •
12
FLAG*
0.1 µF
124 •
18
166 •
V EE
0.1 µF
9*
124 •
16
D
Q
D
Q
11
DATA †
1340
14
FLAG*
0.1 µF
7*
17
10
DATA †
100314
124 •
124 •
100 •
250 •
250 •
100 •
82 •
19
82 •
V BB
–
0.1 µF
+
10 µF
6, 7
1-572(C).b
* 50 Ω to (VCC – 2) V.
† 50 Ω to –2 V. DATA and DATA are 50 Ω impedance transmission lines.
‡ Fair-Rite Products Corporation part number 2743037447 or equivalent.
Figure 5. Interfacing the 155 Mbits/s 1340 Receiver to a True ECL Circuit
6
Agere Systems Inc.
Data Sheet
January 2000
1340-Type Lightwave Receiver
Pin Information
Table 1. Pin Descriptions
Pin Number
Description
1
Ground
2
Ground
3
Ground
4
Ground
5
No User Connection*
6
Ground
7
DATA
8
Ground
9
DATA
10
NIC or Optional VPIN
11
Vcc (5 V)
12
FLAG†
13
Ground
14
FLAG
15
Ground
16
Ground
17
No User Connection*
18
No User Connection*
19
No User Connection*
20
No User Connection*
* Pins designated as no user connection are not connected internally within the receiver. However, to allow for future functional upgrades, it is
recommended that the user not make any connections to these pin positions.
† The link-status flag is a logic output that indicates the presence or absence of a minimum acceptable level of optical input. A logic high on
FLAG indicates the presence of a valid optical signal.
Handling Precautions
Mounting and Connections
The pigtail consists of a 39 in. ± 4 in. (1 m ± 10 cm), 62.5 µm core/125 µm cladding multimode fiber. The standard
fiber has a 0.036 in. (914 µm) diameter tight-buffered outer jacket. The minimum fiber bending radius during operation is 1.0 in. (25.4 mm).
Agere Systems Inc.
7
1340-Type Lightwave Receiver
Data Sheet
January 2000
Electrostatic Discharge
Caution: This device is susceptible to damage as a result of electrostatic discharge (ESD). Take proper
precautions during both
handling and testing. Follow EIA* Standard EIA-625.
Although protection circuitry is designed into the device, take proper precautions to avoid exposure to ESD.
Agere employs a human-body model (HBM) for ESD susceptibility testing and protection-design evaluation. ESD
voltage thresholds are dependent on the critical parameters used to define the model. A standard HBM (resistance
= 1.5 kΩ, capacitance = 100 pF) is widely used and, therefore, can be used for comparison purposes. The HBM
ESD threshold established for the 1340 receiver is ±1000 V.
Receiver Processing
The 1340-type receiver devices can withstand normal wave-soldering processes. The complete receiver module is
not hermetically sealed; therefore, it should not be immersed in or sprayed with any cleaning solution or solvents.
The process cap and fiber pigtail jacket deformation temperature is 85 °C. The receiver pins can be wave-soldered
at maximum temperature of 250 °C for 10 seconds.
Installation Considerations
Although the receiver features a robust design, care should be used during handling. The optical connector should
be kept free from dust, and the process cap should be kept in place as a dust cover when the device is not connected to a cable. If contamination is present on the optical connector, the use of canned air with an extension tube
should remove any debris. Other cleaning procedures are identified in the technical note,Cleaning Fiber-Optic
Assemblies (TN95-010LWP).
* EIA is a registered trademark of Electronic Industries Association.
8
Agere Systems Inc.
Data Sheet
January 2000
1340-Type Lightwave Receiver
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations section of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Parameter
Symbol
Min
Max
Unit
VCC
TC
Tstg
—
λ
—
—
–40
–40
—
1.1
1.0 (25.4)
5.5
85
85
250/10
1.6
—
V
°C
°C
°C/s
µm
in. (mm)
Supply Voltage
Operating Case Temperature Range
Storage Case Temperature Range
Lead Soldering Temperature/Time
Operating Wavelength Range
Minimum Fiber Bend Radius
Operating Characteristics
Minimum and maximum values specified over operating case temperature range and end-of-life (EOL).
Typical values are measured at beginning-of-life (BOL) room temperature unless otherwise noted.
Table 2. Optical Characteristics
Data Rate
(Mbits/s)
Min
Typ*
Max
Unit
PR
155
622
1250
—
—
—
–38
–32
–28
–36
–29
–24
dBm
dBm
dBm
Maximum Input Power*
PMAX
155
622
1250
–3.0
–6.0
–3.0
0
–3.0
–2.0
—
—
—
dBm
dBm
dBm
Link Status Switching Threshold:
Decreasing Light Input
LSTD
155
622
1250
–53.0
–45.0
–36.0
–40
–34
–31.0
–36.0
–28.0
–26.0
dBm
dBm
dBm
Increasing Light Input
LSTI
155
622
1250
–52.5
–45.5
–35.5
–38
–31
–29.0
–35.5
–27.5
–25.5
dBm
dBm
dBm
Hysteresis
HYS
All Data
Rates
0.5
3.0
6.0
dBm
All Data
Rates
0.7
0.8
1.2
A/W
Parameter
Measured Average Sensitivity*
Detector Responsivity
Symbol
R
* For 1 x 10–10 BER with an optical input using a 2 23 – 1 pseudorandom word having a 50% average duty cycle.
Agere Systems Inc.
9
Data Sheet
January 2000
1340-Type Lightwave Receiver
Operating Characteristics (continued)
Table 3. Electrical Characteristics
Parameter
Symbol
Min
Typ
Max
Unit
dc Power Supply Voltage
VCC
4.75
5.0
5.25
V
PIN Photodetector Supply Voltage (Pin 10)*
VPIN
VPIN
4.75
–5.25
5.0
–5.0
5.25
–4.75
V
V
Power Supply Current
ICC
IPIN
—
—
80
—
150
1
mA
mA
Output Data Voltage:†
Low
High
VOL
VOH
VCC – 1.81
VCC –1.025
VCC – 1.70
VCC – 0.95
VCC – 1.62
VCC – 0.88
V
V
Output Rise Time/Fall Time:
OC-3/STM-1 Versions
OC-12/STM-4 Versions
tR/tF
tR/tF
—
—
700
350
1400
400
ps
ps
VFL
VFH
—
VCC – 1.025
VCC – 1.90
VCC – 1.0
VCC – 1.65
—
V
V
VFL
VFH
0
VCC – 0.5
—
—
0.5
VCC
V
V
IOL
IOH
—
—
5
20
50
50
mA
mA
IOL
IOH
—
—
5
20
50
50
mA
mA
IOL
IOH
0
0
10
10
15
15
mA
mA
Output Flag Voltage:
OC-3/STM-1 Versions:‡
Low
High
OC-12/STM-4 Versions:‡
Low
High
Output Data Current:†
Low
High
Output Flag Current:
OC-3/STM-1 Versions:
Low
High
OC-12/STM-4 Versions:
Low
High
* Customers have the option for either a +5 V or –5 V supply.
† Measured from VCC with a 50 Ω load to (VCC – 2) V.
‡ Internally terminated CMOS output.
Qualification Tests and Reliability
To help ensure high product reliability and customer satisfaction, Agere is committed to an intensive quality program that starts in the design phase and proceeds through the manufacturing process. Optoelectronics modules
are qualified to Agere internal standards using MIL-STD-883 test methods and procedures and using sampling
techniques consistent with Telcordia Technologies requirements. The 1340-Type receivers have undergone an
extensive and rigorous set of qualification tests. This qualification program fully meets the intent of Telcordia Technologies reliability practices TR-NWT-000468 and TA-NWT-000983. In addition, the design, development, and manufacturing facility of Agere’s Optoelectronics unit has been certified to be in full compliance with the latest ISO *9001 Quality System Standards.
* ISO is a registered trademark of The International Organization for Standardization.
10
Agere Systems Inc.
Data Sheet
January 2000
1340-Type Lightwave Receiver
Outline Diagram
Dimensions are in inches and (millimeters). Unless noted otherwise, tolerances are 0.005 in. (0.127 mm).
1.339
(34.01)
0.968
(24.58)
PIN 1 INDICATOR
0.147
(3.73)
0.635
(16.14)
TOP VIEW
0.350 (8.89)
0.110
(2.80)
0.100
(2.54)
0.125
(3.17)
0.018
(0.46)
0.900
(22.86)
PIN 11
PIN 20
0.400
(10.16)
PIN 10
PIN 1
1-988(C)
Agere Systems Inc.
11
1340-Type Lightwave Receiver
1340-Type
Lightwave Receiver
for
OC-1,3/STM-1
Advance Data Sheet
January 2000
Ordering Information
Table 4. OC-3/STM-1 Receiver Versions
Device Code
Connector
Pin 10 Requirements
Comcode
1340FMPC
1340CMPC
1340TMPC
1340FAPC
1340CAPC
1340TAPC
FC-PC
SC
ST
FC-PC
SC
ST
No
Internal
Connection
Requires +5 V or –5 V
(Used for photocurrent
monitoring)
108162322
108354408
108572264
108468687
108359175
108572249
Table 5. OC-12/STM-4 Receiver Versions
Device Code
Connector
Pin 10 Requirements
Comcode
1340FNPC
1340CNPC
1340TNPC
1340FBPC
1340CBPC
1340TBPC
FC-PC
SC
ST
FC-PC
SC
ST
No
Internal
Connection
Requires +5 V or –5 V
(Used for photocurrent
monitoring)
108155680
108354416
108155755
108155672
108468679
108572256
Table 6. 1.25 Gbits/s Receiver Versions
Device Code
Connector
Pin 10 Requirements
Comcode
1340FCPC
1340CCPC
FC-PC
SC
Requires
+5 V or –5 V
108400342
108400334
Table 7. Related Products
Description
1241/1243/1245-Type Receivers for SONET/SDH Applications
1345-Type Receiver with Clock Recovery and Data Retiming
Document Number
DS99-073LWP
DS00-099OPTO
For additional information, contact your Agere Systems Account Manager or the following:
INTERNET:
http://www.agere.com
E-MAIL:
[email protected]
N. AMERICA: Agere Systems Inc., 555 Union Boulevard, Room 30L-15P-BA, Allentown, PA 18109-3286
1-800-372-2447, FAX 610-712-4106 (In CANADA: 1-800-553-2448, FAX 610-712-4106)
ASIA:
Agere Systems Hong Kong Ltd., Suites 3201 & 3210-12, 32/F, Tower 2, The Gateway, Harbour City, Kowloon
Tel. (852) 3129-2000, FAX (852) 3129-2020
CHINA: (86) 21-5047-1212 (Shanghai), (86) 10-6522-5566 (Beijing), (86) 755-695-7224 (Shenzhen)
JAPAN: (81) 3-5421-1600 (Tokyo), KOREA: (82) 2-767-1850 (Seoul), SINGAPORE: (65) 778-8833, TAIWAN: (886) 2-2725-5858 (Taipei)
EUROPE:
Tel. (44) 7000 624624, FAX (44) 1344 488 045
Agere Systems Inc. reserves the right to make changes to the product(s) or information contained herein without notice. No liabi lity is assumed as a result of their use or application. ST is a
registered trademark of Agere Systems Inc.
Copyright © 2000 Agere Systems Inc.
All Rights Reserved
Printed in U.S.A.
January 2000
DS00-098OPTO (Replaces DS99-072LWP)