CT1820 Data Terminal Bit Processor for MIL-STD-1553 A & B Features General Description E I NC . C 1 ISO S A E RO B • Performs Encoder, Decoder, Logic and Control functions of a Data Bus Terminal to MIL-STD-1553 specifications, including Address, Mode Code and Broadcast Decoding and Terminal Fail Safe • Flexibility - all control lines accessible • Parallel tri-state subsystem l/O bus compatible with both 16 bit and 8 bit systems • Dual rank l/O registers for versatile subsystem tlmlng X LA LE • Operates from +5VDC @ 40mA typical (25mA CT1820) F • Self-contained oscillator and clock driver • Look-ahead serial receive data output • Self-test, on-line wraparound, plus off-line capability 9001 RTIFIED 43 43 43 LOAD DATA 2 SECOND RANK XMT REG DO - D7 LOAD DATA 1 FIRST RANK XMT REG DO - D7 LATCH DATA 1 53 LATCH DATA 2 56 54 6 5 4 3 2 42 41 44 50 48 47 46 45 56 (OPTIONAL) SERIAL INPUT D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 (MSB) D15 SECOND RANK REC’V REG DO - D7 (LSB) D0 FIRST RANK REC’V REG DO - D7 DATA SELECT 1 7 43 DATA SELECT 2 The CT1555-3/CT1820 Bit Processor Unit (BPU) is an advanced Hybrid Microcircuit that provides the interface between a MIL-STD-1553 Transceiver such as CT3231M or CT3232M, and the subsystem internal parallel data bus. The unit can be employed as the mux bus interface for Remote Subsystems or Master Terminal Bus Controllers, thus providing a common interface for all systems communicating over the bus. The unit places no restrictions on Command, Response or polling operations as it transfers all Command, Status and Data words from the bus to parallel output lines, together with error information, bus status and handshaking signals. It also contains 5 Bit Address Recognition, Broadcast and Mode Code Decode, Terminal Fail Safe Signal and Self Test. In the transmit mode, it accepts parallel data from the user and transmits Command, Status and Data words, under subsystem control, to the data bus. Positive handshaking signals provide logic control synchronisation between the unit and the subsystem for direct data flow. The hybrid is completely compatible with all the electrical and functional spec requirements of MIL-STD-1553 A & B. Vcc 1 +5V GND GND 11 34 FIRST RANK REC’V REG D8 - D15 { 5 BIT ADDRESS SECOND RANK XMT REG D8 - D15 BUILT IN TEST SELECT (MSB) A4 A3 ADDRESS DECODE A1 (LSB) A0 BROADCAST DATA OUT MANCHESTER DECODER & CONTROL LOGIC 10 39 DATA IN BIT SELECT A2 9 13 20 DATA IN RT ENABLE 12 8 CASE SERIAL DATA OUT 36 32 FIRST RANK XMT REG D8 - D15 SECOND RANK REC’V REG D8 - D15 MANCHESTER ENCODER & CONTROL LOGIC BROADCAST DECODE DATA OUT FAIL SAFE TIMER & CONTROL FAIL SAFE SEND DATA ESCOUT SYNC SEL 40 14 16 33 37 31 MODE CODE ENC ENA MODE CODE DECODE OUTPUT INH MRST VALID WORD COMM/DATA SYNC DEC RST TAKE DATA +5V OSC / CLOCK POWER OSC & CLOCK DRIVER XTAL CLOCK OUT 21 22 19 25 26 15 27 28 24 23 35 38 30 29 18 DSC OUT CLOCK IN 17 Figure 1 – Functional Diagram eroflex Circuit Technology – Data Bus Modules For The Future © SCDCT1820 REV D 6/25/99 RX DATA IN 32 DATA OUT 25 TX DATA OUT 26 DATA 25 33 DATA IN 1 TX DATA OUT CT1820 OR CT1553 BIT PROCESSOR CT3231 T/R HYBRID DATA BUS TX DATA OUT TX DATA IN 7 2 RX DATA OUT RX DATA 10 OUT 26 RX DATA IN DATA IN 21 DATA IN 29 16 BIT OR 8 BIT SUBSYSYEM XTAL 12 MHz 22 CONTROL 31 TX INHIBIT Figure 2 – Typical MIL-STD-1553 Data Terminal Absolute Maximum Ratings Parameter Units +7.0 V Logic Input Voltage -0.3 to +5.5 V Logic Input Current -20 to +4 mA 15 mA -0.3 to VCC +0.3V V Storage Temperature Range -65 to +150 °C Operating Case Temperature Range -55 to +125 °C Supply Voltage Clock Output Current (Pin 18) Clock In (Pin 17) Electrical Characteristics (VCC = 5.0V ±5%) Sym Parameter / Conditions Min Typ VIH Logic "1" Input Voltage 2.0 - - V VIL Logic "0" Input Voltage - - 0.7 V VOH Logic "1" Output Voltage See Pin assignments and Loading VOL Logic "0" Output Voltage See Pin assignments and Loading VIHC Logic "1" Input Voltage (CLOCK) VCC-0.5 - V VILC Logic "0" Input Voltage (CLOCK) - GND+0.5 V VOHC Logic "1" Output Voltage (CLOCK) VCC-0.3 - V VOLC Logic "0" Output Voltage (CLOCK) - GND+0.3 V lOC Logic Supply Current - 40 - mA lOSC Oscillator / Clock Supply Current 8 13 mA Aeroflex Circuit Technology 2 Max Units SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 PIN ASSIGNMENTS AND LOADING In the following table, the symbols are defined as follows: IIH= maximum input HIGH current with V IN = 2.5 volts IIL = maximum input LOW current with VIN = 0.4 volts IOH = maximum output HIGH current for VOUT = 2.5 volts minimum IOL = maximum output LOW current for VOUT = 0.4 volts maximum * Indicates use of an internal pull-up resistor Pin No Name CT1555-3 CT1820 CT1820-2 I IH (µA) IIL (µA) IOH IOL IIH IIL IOH (µA) (mA (µA) (µA) (µA) 40 -0.4 -1000 2.4 20 Description IOL (mA IOL (mA) 20 -0.4 -1000 6.0 10.0 -0.4 20 -0.4 A LOW on this input applies the contents of the SECOND RANK REC’V REG to the D8-D15 I/O pins -1500 -3.2 20 -0.4 Part of 5 Bit ADDRESS INPUT -1500 -3.2 20 -0.4 1 VCC 2 D8 +5V Power Input 3 D9 4 D10 5 D11 6 D12 7 DATA SELECT 1 8 A3* 9 A2* 10 A1* 11 GROUND 12 A4* 13 A0* 14 VALID WORD -400 2.4 -400 4.0 4.0 A LOW on this output indicates receipt of avalid word 15 FAIL SAFE -400 2.4 -400 4.0 4.0 A HIGH on this output indicates termination of a transmitted message that exceeds 768µs. 16 COMM / DATA SYNC - 380 2.4 -400 4.0 4.0 A HIGH on this output indicates COMMAND (or STATUS) word reception. A LOW indicates DATA word reception. 17 CLOCK IN 18 CLOCK OUT 19 S / T SELECT 20 CASE 21 Part of 16 Bit TRI-STATE l/O Logic and power return MSB of 5 Bit ADDRESS INPUT LSB of 5 Bit ADDRESS INPUT ±30 ±0.003 +100 +100 -3 -3 -1000 1.0 Input for 12MHz clock (20pf load). -1000 1.0 1.0 Output of OSCILLATOR AND CLOCK DRIVER. 40 -0.8 20 -0.4 DATA IN 20 -0.4 20 -0.4 A HIGH on this input represents a positive state on the bus. 22 DATA IN 20 -0.4 20 -0.4 A HIGH on this input represents a negative state on the bus. (Pins 21 and 22 must both be high when the bus is inactive.) 23 ENC ENA 20 -0.4 20 -0.4 A LOW on this input initiates a transmit cycle. 24 SYNC SEL 20 -0.4 20 -0.4 Actuates COMMAND (or STATUS) sync for an input LOW and DATA sync for an input HIGH. 25 DATA OUT 360 2.4 -400 4.0 4.0 A HIGH on this output produces a positive state on the bus. 26 DATA OUT 360 2.4 -400 4.0 4.0 A HIGH on this output produces a negative state on the bus. 27 SEND DATA 380 2.4 -400 4.0 4.0 A HlGH on this output indicates data shifting during the transmit cycle. 28 ESC OUT 1000 1.2 -1000 1.2 1.2 LOW to HIGH transitions on thls output during HIGH SEND DATA cause the transmit cycle data shifting to occur. 29 XTAL 30 +5V OSC POWER 31 DSC OUT -1000 1.2 -1000 1.2 1.2 LOW to HIGH transitions on this output during LOW TAKE DATA cause receive cycle data shifting to occur. 32 RT ENABLE -400 -400 4.0 A HIGH on this output indicates reception of a valid COMMAND (or STATUS) word containing the terminalís address. It also resets the FAIL SAFE. Aeroflex Circuit Technology A HIGH on this input sets the unit in the self test mode. CASE CONNECTION A 12MHz (parallel resonant) crystal is connected between this pin and ground. / CLOCK +5V power for OSCILLATOR AND CLOCK POWER DRIVER. 2.4 3 4.0 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 Pin No Name CT1555-3 CT1820 CT1820-2 I IH (µA) IIL (µA) IOH IOL IIH IIL IOH (µA) (mA (µA) (µA) (µA) 20 -0.4 20 -0.4 20 -0.4 20 -0.4 IOL (mA Description IOL (mA) 33 DEC RST A LOW on this input (for 1µs minimum) resets the decoder to a condition ready for a new word, resets the COMM / DATA SYNC output LOW, and resets the VALID WORD output HIGH. 34 GROUND 35 OUTPUT INH 36 SERIAL DATA OUT -400 1.6 -400 4.0 4.0 The received serial data in NRZ format is available at this pin during LOW TAKE DATA. 37 TAKE DATA -360 2.4 -400 4.0 4.0 A LOW on this output indicates data shifting during the receive cycle. 38 MRST 39 BROADCAST* -300 1.6 -400 4.0 4.0 A HIGH on this output indicates reception of a valid COMMAND (or STATUS) word containing all ONES in the address field. 40 MODE CODE* -600 2.4 -600 6.0 6.0 A LOW on this output indicates reception of a valid COMMAND (or STATUS) word containing all ONES or all ZEROS in the sub-address field. 41 D6 20 -0.4 -1000 6.0 10.0 Part of 16 Bit TRI-STATE l/O 42 D7 43 20 -0.4 20 -0.4 -1000 6.0 Logic and Power Return. 60 -1.2 20 -0.4 A LOW on this input (for 1µs minimum) interrupts and clears the transmit cycle, resets the FAIL SAFE, and also performs the same functions as DEC RST. 40 -0.4 DATA SELECT 2 20 -0.4 44 D5 40 -0.4 45 D0 LSB of 16BIT TRI-STATE I/O 46 D1 Part of 16 Bit TRI-STATE l/O 47 D2 Part of 16 Bit TRI-STATE l/O 48 D3 49 LATCH DATA 2 20 -0.4 50 D4 40 -0.4 51 LOAD DATA 2 60 -1.2 A LOW on this input loads the D0-D7 data into the SECOND RANK XMT REG. A HIGH on this input then locks out the data inputs to permit serial shifting. 52 LATCH DATA 1 20 -0.4 A HIGH on this input allows the l/O data on D8-D15 to appear at the output of the FIRST RANK XMT REG. A LOW on this input holds the register outputs in their last state. 53 LOAD DATA 1 60 -1.2 54 D13 40 -0.4 55 D14 56 D15 Aeroflex Circuit Technology -1000 2.4 A LOW on this input holds output pins 25 and 26 LOW. -1000 2.4 A LOW on this input applies the contents of the SECOND RANK REC’V REG to the D0-D7 I/O pins. 10.0 Part of 16 Bit TRI-STATE l/O Part of 16 Bit TRI-STATE l/O A HIGH on this input allows the l/O data on D0-D7 to appear at the output of the FIRST RANK XMT REG. A LOW on this input holds the register outputs in their last state. -1000 2.4 -1000 6.0 20 -1000 2.4 Part of 16 Bit TRl-STATE l/O -0.4 A LOW on this input loads the D8-D15 data into the SECOND RANK XMT REG. A HIGH on this input then locks out the data inputs to permit serial shifting. -1000 6.0 4 10.0 Part of 16 Bit TRl-STATE l/O. OPTIONAL SERIAL INPUT. SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 TRANSMIT CYCLE OPERATION SEND DATA remains high for 16 ESC periods, during which the parallel transmit data is clocked to the MANCHESTER ENCODER ③ to ④. After the sync and Manchester coded data are transmitted through the DATA OUT and DATA OUT outputs, the ENCODER adds on the parity bit for that word ⑤. ENCODER SHIFT CLOCK (ESC) (see Figure 3) operates at the data rate (1MHz). A low at ENCODER ENABLE (ENC ENA) during a falling edge of ESC ① starts the Transmit cycle, which lasts for twenty ESC clock periods. The SYNC SELECT (SYNC SEL) input is valid at the next low-to-high transition of ESC ②. A high at SYNC SEL will produce a data sync, or a low will produce a command sync for that word. If the transmitted word is to be the last word of the transmission, ENC ENA must go high by ⑤ to prevent initiation of another transmit cycle. At any time, a low applied to OUTPUT INHIBIT will force both DATA OUT and DATA OUT to a low state without affecting any other operations. Parallel data must be stable at the second rank transmit register before SEND DATA goes high ③. Since ENC ENA is not synchronous with ESC, the minimum time to ③ is 3µsec from ENC ENA leading edge. The entire transmit cycle may be interrupted and cleared by applying a minimum of 1µsec negative pulse to the MASTER RESET (MRST) input. For 8-BlT I/O subsystems, D0 is tied to D8, D1 to D9, etc., through D7 tied to D15, and data is inputted in 8-BlT bytes by using LATCH DATA 1 and LATCH DATA 2 and / or LOAD DATA 1 and LOAD DATA 2 independently. The first-rank transmit register may be operated transparently (LATCH DATA always high), or may be used to hold data ready for transmission, independent of the activity on the 16-line subsystem l/O bus. As long as LATCH DATA is held high, data present on the subsystem l/O bus appears at the output of the first rank transmit register. Stable data may be latched and held at the first rank register output by bringing LATCH DATA low. Data to be transmitted may be latched any time before the low-to high transition of SEND DATA (SEND DATA, when appled to the LOAD DATA inputs, locks out the data inputs to the second rank transmit register.) For multiple word transmissions, the next word may be inputted and latched any time after ③, but before the next low to-high transition of SEND DATA. 0 1 2 3 4 5 16 17 For serial data applications, D15 input serves as the serial transmit input. With LOAD DATA 1 held low and LATCH DATA 1 held high, D15 input is applied to the ENCODERís serial data input. Inputted data must be at the ESC rate with the MSB starting at the low-to-high transition of SEND DATA. If a message length ever exceeds 768µsec, the 768µsec TIME OUT (FAIL SAFE) flag goes high, and DATA OUT and DATA OUT are both forced to a low state. This condition will remain until a valid command word (containing the terminalís address) is received or until MRST goes low. 18 19 0 1 2 3 4 5 16 17 18 19 ESC ENC ENA SYNC SEL DON’T CARE VALID VALID DON’T CARE DATA SELECT LATCH DATA DON’T CARE DON’T CARE DEPENDS ON "LATCH" TIMING DON’T CARE SEE TEXT DEPENDS ON "LATCH" TIMING SEE TEXT OPTIONAL NEXT-WORD LATCH OPTIONAL NEXT-WORD LATCH SEND DATA & LOAD DATA DATA OUT ½ SYNC ½ SYNC 15 14 13 2 1 0 P ½ SYNC ½ SYNC 15 14 13 2 1 0 P DATA OUT ½ SYNC ½ SYNC 15 14 13 2 1 0 P ½ SYNC ½ SYNC 15 14 13 2 1 0 P IF USED 1 2 3 4 5 Figure 3 – Transmit Cycle Timing Aeroflex Circuit Technology 5 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 0 2 1 ENCODER SHIFT CLOCK TE1 ENCODER ENABLE TE 3 TE2 SYNC SELECT VALID TE 5 TE 4 SEND DATA & LOAD DATA TE6 LATCH DATA (IF USED) TE7 TE8 PARALLEL DATA IN TE 9 TE10 DATA SELECT TE11 Symbol Description Min Max Units TE1 ENCODER ENABLE SET-UP TIME 100 - ns TE2 ENCODER ENABLE PULSE WIDTH 180 - ns TE3 SYNC SELECT SET-UP TIME 190 - ns TE4 SYNC SELECT 'VALID' PULSE WIDTH 150 - ns TE5 SEND DATA DELAY - 70 ns TE6 LATCH DATA HOLD TIME 25 - ns TE7 LATCH DATA SET UP TIME 50 - ns TE8 LATCH DATA PULSE WIDTH LOW 50 - ns TE9 PARALLEL DATA 'VALID' WIDTH 75 - ns TE10 DATA SELECT DISABLE TIME 25 - ns TE11 DATA SELECT PULSE WIDTH HIGH 100 - ns Figure 4 – Encoder Timing Detail Aeroflex Circuit Technology 6 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 RECEIVE CYCLE OPERATION bus by setting DATA SELECT lines low. DECODER SHIFT CLOCK (DSC) (see Figure 5) operates at the data rate (1MHz). When the DECODER recognises a valid sync and two valid Manchester data bits ①, a receive cycle is initiated. The new sync is indicated at the COMMAND/DATA SYNC (C/D SYNC) output and the TAKE DATA output goes low ②. The C/D sync output will remain in its valid state until a new sync is detected on a subsequent word or until DECODER RESET (DEC RST) or MRST goes low. A low at DEC RST or MRST causes C/D SYNC to go low. After all data has been loaded into the receive registers, the data is checked for odd parity. A low on VALID WORD (VW) output ③, indicates successful reception of a word without any Manchester or parity errors. For consecutive word receptions, VW will go high again in 3 to 3.5µs. In the absence of succeeding valid syncs, VW will return high in 20µs. A DEC RST (low) at any time will reset VW high. All decoded commands, including RT ENABLE (address recognition), BROADCAST and MODE CODE are enabled internally by VW and remain valid only as long as VW is low. TAKE DATA remains low for 16 DSC periods during which time the 16 serial data bits appear at the SERIAL DATA OUTPUT (SDO). This data is simultaneously loaded into the first-rank receive register. The low-to-high transition of TAKE DATA ③ makes the new data available at the output of the second-rank receive register. This data remains available until the next low-to-high transitions of TAKE DATA. It is not reset or cleared by any other signals. This data is applied to the D0 to D15 I/O 0 1 2 3 4 5 16 17 18 19 For 8-BIT l/O subsystems (D0 tied to D8, through D7 tied to D15), data may be extracted in 8 BIT bytes by selectively activating DATA SELECT 1 and DATA SEL.ECT 2. For serial data systems, SERIAL DATA OUTPUT is available at the DSC rate from ② to ③. 0 1 2 3 4 5 16 17 18 19 OSC DATA IN ½ SYNC ½ SYNC 15 14 13 2 1 0 P ½ SYNC ½ SYNC 15 14 13 2 1 0 P DATA IN ½ SYNC ½ SYNC 15 14 13 2 1 0 P ½ SYNC ½ SYNC 15 14 13 2 1 0 P TAKE DATA C/D SYNC SDO VW VALID FOR CURRENT WORD FROM PREVIOUS WORD 15 UNDEFINED 4 3 2 1 0 VALID FOR CURRENT WORD UNDEFINED 15 4 3 2 1 0 FROM PREVIOUS WORD DECODE COMMANDS (see text) SECOND-RANK REC’V REGISTER CONTENT DATA SELECT VALID NOT VALID FROM PREVIOUS WORD NEW DATA OPTIONAL–HIGH = TRISTATE HI-Z AT D0 TO D15 1 NOT VALID VALID NEW DATA OPTIONAL–HIGH = TRISTATE HI-Z AT D0 TO D15 3 2 4 Figure 5 – Receive Cycle Timing Aeroflex Circuit Technology 7 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 4 5 19 DECODER SHIFT CLOCK TD1 TD 2 TAKE DATA TD 3 C/D SYNC LAST STATE NEW SYNC TD4 VALID WORD LAST STATE TD 5 BROADCAST TD 6 RT ENABLE TD 7 MODE CODE TD8 DATA SELECT TD 9 PARALLEL DATA OUT Symbol NEW DATA Description Min Max Units TD1 TAKE DATA RELAY ON - 125 ns TD2 TAKE DATA DELAY OFF - 125 ns TD3 SYNC DELAY - 50 ns TD4 VALID WORD DELAY - 125 ns TD5 BROADCAST DELAY - 70 ns TD6 RT ENABLE DELAY - 100 ns TD7 MODE CODE DELAY - 100 ns TD8 DATA SELECT INPUT DELAY 0 (Note 1) - ns TD9 PARALLEL DATA OUTPUT DELAY - 50 (Note 2) ns Notes: 1. DATA SELECT may be applied at any tlme that the 16 line I/O is otherwise free. The parallel DATA OUT, however, is not ’NEWDATA’ until 50ns after TAKE DATA goes high. 2. 180ns max for CT1555-3. Figure 6 – Decoding Timing Detail Aeroflex Circuit Technology 8 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 SELF TEST FUNCTION clock or an external clock source. A high on the S/T SELECT input sets the hybrid in the SELF TEST mode. In this mode, the DATA and DATA output lines are connected to the Decoder inputs so that the unit may operate in the "wraparound" mode without actually going through the data bus transceiver. Note that the DATA and DATA output lines are active in this mode and the S/T SELECT command must also be used to inhibit the data bus transmitter to prevent arbitrary transmission on the data bus. For internal clock operation, a 12MHz parallel-resonant fundamental-mode crystal must be connected from XTAL to ground. Power (+5V) must be applied to +5V OSC/CLOCK POWER and CLOCK OUT must be connected to CLOCK IN. For external clock operation, no power is applied to +5V OSC/CLOCK POWER and the external clock is applied to CLOCK IN (CLOCK OUT not connected). The external clock must be capable of driving a 20 picofarad load to within 0.5 volts of VCC and within 0.5 volts of ground with rise and fall times of less than 10 nanoseconds. Standard TTL levels are not satisfactory. For a normal 1MHz data rate, the clock frequency must be 12MHz. TERMINAL FAIL SAFE In order to satisfy the Terminal Fail Safe requirements of MIL-STD-1553B, the DATA and DATA output lines are continuously monitored for length of message. A transmitted message in excess of 768µs sets the FAIL SAFE output high and terminates the transmission by setting both DATA and DATA output lines low. As a redundant safety factor, the FAlLSAFE output may be applied to the lNHlBlT input of the data bus transmitter (if so equipped). Further transmissions are prevented until the FAIL SAFE flag is reset either by reception of a valid command word containing the terminal address or by a negative pulse on the MRST input. Note: Transmissions containing gaps of 3µs or less are considered continuous, even if the gap is caused by a MRST pulse. FALSE RT ENABLE Terminals that continuously monitor their own transmissions are subject to "END-AROUND" operation due to a false RT ENABLE. The terminal can erroneously interpret its own status word as a new command word. If no measures are taken to prevent or re-set RT ENABLE, it will remain high for 20µs or until the DECODER recognises a new valid sync (whichever time is shorter). RT ENABLE may be inhibited by interrupting the RECEIVE CYCLE during a status word transmission. Inverted SEND DATA applied to DEC RST will prevent reception of the status word. If continuous monitoring is required, RT ENABLE may be reset immediately after it goes high by a 1µs (minimum) low at DEC RST. The status word will then be available at the second-rank receive register. TERMINAL ADDRESS LINES The five-bit terminal address is set by hard wiring the 5-BlT ADDRESS lines. The hybrid contains internal pull-up resistors so that logic "1" lines may be left open circuited. Logic "0" lines must be grounded. In operation, RT ENABLE goes high when a valid command word containing the hard-wired address is received. See "RECEIVE CYCLE OPERATION" for timing. OSCILLATOR AND CLOCK DRIVER The hybrid may be operated with either the internal Aeroflex Circuit Technology 9 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700 CIRCUIT TECHNOLOGY Ordering Information Model Number Package 2.155" x 1.14" Metal Plug In CT1820 Plug-In Package Outline 2.155 MAX 1.900 29 48 49 28 TOP VIEW .450 REF 1.155 .900 56 21 1 20 .100 TYP .200 MAX .175 MIN .018 DIA TYP ±.002 Aeroflex Circuit Technology 35 South Service Road Plainview New York 11830 Telephone: (516) 694-6700 FAX: (516) 694-6715 Toll Free Inquiries: 1-(800)THE-1553 Specifications subject to change without notice. Aeroflex Circuit Technology 10 SCDCT1820 REV D 6/25/99 Plainview NY (516) 694-6700