POWER-SYSTEMS CXA-L10L

DC-AC INVERTER UNIT
CXA-L10L (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
DESCRIPTION :
TDK DC/AC Inverter, CXA-series, are low-noise, high frequency
power sources developed for driving Cold Cathode Fluorescent
Lamps operating at 20~80 kHz. These inverters are designed to
handle a wide range of lamp characteristics.
FEATURES :
Constant current output ensures compatibility with a wide
range of discharge lamps.
High efficiency resonant circuitry produces low-noise,
sinusoidal-wave output.
One-lamp/two-lamp combined-use capability allows use in
four different configurations.
Common ground or floating bulb configurations.
Compact size and light weight facilitate PC board mounting.
High Efficiency (80%)
TEMPERATURE & HUMDITY :
Operating Temperature Range
-10 °C ~ +60°C
Storage Temperature Range
-20 °C ~ +85°C
Humidity
95%RH max (No dew)
DIMENSIONS :
(Bottom View)
(Side View)
21Max
16.5±0.2
15.24±0.2
Weight: 11.4 (g) typ.
(1.0)
2
3
5
7.5±0.2
44Max
38.1±0.2
5.08±0.2
3-φ1.6±0.15
26±0.2
1
Unit : mm
5Min 13Max
4
Jumper (*1)
0.5±0.2
R1.15±0.2
5-φ0.8±0.1 or 5- 0.64±0.07
(Solder plated obstinate copper wire)
*1 Remove for Isolated
Ground
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 1 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-L10L (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
CONNECTOR CONFIGURATION:
Pin No. Symbols
ABSOLUTE MAXIMUM RATINGS:
Ratings
Items
Symbols
Specification
Unit
12V
Input Voltage
Vin
0~14.4
VDC
Output Power
Pout
4.5
W
Vin
1
(STANDARD)
2
GND
0V
3
OUT1
300Vrms
4
OUT2
300Vrms
5
OUT GND
0V
ELECTRICAL CHARACTERISTICS:
Ite m s
S ym bols
Output
Curre nt
Iout
Input Curre nt
Fre que ncy
Conditions
V in [V ]
Ta [°C]
S pe cifica tion
RL [K Ω ]
M in.
Typ.
Max.
Unit
12±0.12
23±5
30
9
10
11
12±0.6
-10~ 60
23~ 37
8
10
12
Iin
12±0.6
-10~ 60
23~ 37
-
320
480
m A DC
F
12±0.6
-10~ 60
23~ 37
25
30
35
kHz
Ope n Circuit
V olta ge
V ope n
12±0.6
-10~ 60
∞
800
900
-
V rm s
Output
Curre nt
Iout
Input Curre nt
Iin
12±0.6
-10~ 60
Fre que ncy
F
12±0.6
-10~ 60
Ope n Circuit
V olta ge
V ope n
m Arm s
12±0.12
23±5
50
5.3
6
6.7
12±0.6
-10~ 60
38~ 62
4.7
6
7.3
38~ 62
-
200
300
m A DC
38~ 62
30
35
40
kHz
V rm s
12±0.6
-10~ 60
∞
800
900
-
12±0.12
23±5
60
4.5
5
5.6
12±0.6
-10~ 60
45~ 75
4.0
5
6.1
Conne ction
1
m Arm s
Output
Curre nt
Iout
Input Curre nt
Iin
12±0.6
-10~ 60
45~ 75
-
180
270
m A DC
Fre que ncy
F
12±0.6
-10~ 60
45~ 75
25
30
35
kHz
Ope n Circuit
V olta ge
V ope n
12±0.6
-10~ 60
∞
800
900
-
V rm s
Output
Curre nt
Iout1 /
Iout2
12±0.12
23±5
60
4.5/4.5
5/5
5.5/5.5
12±0.6
-10~ 60
45~ 75
4/4
5/5
6/6
Input Curre nt
Iin
12±0.6
-10~ 60
45~ 75
-
320
480
m A DC
Fre que ncy
F
12±0.6
-10~ 60
45~ 75
25
30
35
kHz
Ope n Circuit
V olta ge
V ope n
12±0.6
-10~ 60
∞
800
900
-
V rm s
2
m Arm s
3
m Arm s
4
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 2 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-L10L (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
APPLICATION
Connection 1
Connection 3
Pin1 (Vin)
Vin
Pin3 (out1)
Pin4 (out2)
Pin2 (GND)
Pin1 (Vin)
CCFL
Vin
CCFL
Pin4 (out2)
Pin5 (out GND)
Pin2 (GND)
Connection 2
Pin3 (out1)
Pin5 (out GND)
Connection 4
Pin1 (Vin)
Vin
Pin3 (out1)
Pin4 (out2)
Pin2 (GND)
Pin1 (Vin)
CCFL
Pin3 (out1)
CCFL2
Vin
Pin4 (out2)
Pin5 (out GND)
Pin2 (GND)
CCFL1
Pin5 (out GND)
Note 1.
For circuit connection, please prefer to test circuit diagram.
Note 2.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
Note 4.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
Note 5.
For operation in floating mode, please remove jumper (J1) on top side of PCB that pin2 and pin5.
Note 6.
To prevent electrical discharge from high voltage area, please use non-conductive fastener in U mounting
hole.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 3 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-L10L (4.5W DUAL OUTPUTS, PCB MOUNTABLE TYPE)
(STANDARD)
TEST CIRCUIT:
Connection
Test circuit
lin
A
(1)Vin
V Vin
Notes
OUT1(3)
OUT2 (4)
1
RL
Short of OUT1,OUT2
(2)GND
OUT GND(5)
1000:1
lin
A
(1)Vin
V Vin
A
lout
V
OUT1 (3)
OUT2(4)
NC
OUT GND(5)
A
2
RL
Open of OUT2
(2)GND
1000:1
lin
A
(1)Vin
V Vin
3
lout
V
OUT1 (3)
RL
OUT2(4)
Short of OUT2,OUT GND
(2)GND
OUT GND(5)
1000:1
lin
A
(1)Vin
V Vin
A
lout
V
OUT1 (3)
OUT2 (4)
4
(2)GND
OUT GND(5)
1000:1
V
RL1
lout2
A
RL2
A
lout1
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 4 / 4 )
VER, 04 October 2002