ETC CY7C457-30JC

57
CY7C455
CY7C456
CY7C457
512 x 18, 1K x 18, and 2K x 18 Cascadable
Clocked FIFOs with Programmable Flags
Features
• Depth Expansion Capability
• 52-pin PLCC and 52-pin PQFP
• High-speed, low-power, first-in first-out (FIFO)
memories
• 512 x 18 (CY7C455)
• 1,024 x 18 (CY7C456)
• 2,048 x 18 (CY7C457)
• 0.65 micron CMOS for optimum speed/power
• High-speed 83-MHz operation (12 ns read/write cycle
time)
• Low power — ICC=90 mA
• Fully asynchronous and simultaneous read and write
operation
• Empty, Full, Half Full, and programmable Almost Empty
and Almost Full status flags
• TTL compatible
• Retransmit function
• Parity generation/checking
• Output Enable (OE) pins
• Independent read and write enable pins
• Center power and ground pins for reduced noise
• Supports free-running 50% duty cycle clock inputs
• Width Expansion Capability
The CY7C455, CY7C456, and CY7C457 are high-speed,
low-power, first-in first-out (FIFO) memories with clocked read
and write interfaces. All are 18 bits wide. The CY7C455 has a
512-word memory array, the CY7C456 has a 1,024-word
memory array, and the CY7C457 has a 2,048-word memory
array. The CY7C455, CY7C456, and CY7C457 can be cascaded to increase FIFO depth. Programmable features include Almost Full/Empty flags and generation/checking of parity. These FIFOs provide solutions for a wide variety of data
buffering needs, including high-speed data acquisition, multiprocessor interfaces, and communications buffering.
These FIFOs have 18-bit input and output ports that are controlled by separate clock and enable signals. The input port is
controlled by a free-running clock (CKW) and a write enable
pin (ENW).
Pin Configurations
D0 – 17
INPUT
REGISTER
FL/RT
XI
READ
POINTER
RESET
LOGIC
EXPANSION
LOGIC
XI
HF
ENW
E/F
CKW
PAFE/XO
HF
E/F
XO/PAFE
Q0
Q1
Q2
Q3
8
9
10
11
12
13
14
15
16
17
18
19
20
7C455
7C456
7C457
21 22 23 24 25 26 27 28
THREE–STATE
OUTPUT REGISTER
RETRANSMIT
LOGIC
READ
CONTROL
D11
D12
D9
D10
46
45
44
43
42
41
40
39
38
37
36
35
34
29 30 31 32 33
D13
D14
D15
D16
D17
FL/RT
MR
CKR
ENR
OE
Q17/PG2/PE2
Q16
Q15
Q14
MR
RAM
ARRAY
512 x 18
1024 x 18
2048 x 18
D2
D1
D0
Q11
Q12
Q13
FLAG
LOGIC
WRITE
POINTER
7 6 5 4 3 2 1 52 51 50 49 48 47
FLAG/PARITY
PROGRAM
REGISTER
PARITY
WRITE
CONTROL
VCC
VCC(N)
D3
D4
D5
D6
D7
D8
VSS
ENW
Q4
Q5
Q6
Q7
Q8/PG1/PE1
VSS
CKW
PLCC
Top View
VSS(N)
Q9
Q10
Logic Block Diagram
Functional Description
OE
Q0 – 7, Q8/PG1/PE1
Q9– 16, Q17/PG2/PE2
Cypress Semiconductor Corporation
Document #: 38-06003 Rev. **
•
CKR
ENR
3901 North First Street
c455-1
•
c455-2
San Jose
•
CA 95134 • 408-943-2600
Revised January 3, 1997
CY7C455
CY7C456
CY7C457
Pin Configurations (continued)
Functional Description (continued)
D9
D10
D11
D12
VCC
VCC(N)
D3
D4
D5
D6
D7
D8
VSS
PQFP
Top View
52 51 50 49 48 47 46 45 44 43 42 41 40
D2
D1
D0
XI
ENW
CKW
HF
E/F
XO/PAFE
Q0
Q1
Q2
Q3
1
2
3
4
5
6
7
8
9
10
11
12
13
7C455
7C456
7C457
14 15 16 17 18 19 20 21
39
38
37
36
35
34
33
32
31
30
29
28
27
22 23 24 25 26
D13
D14
D15
D16
D17
FL/RT
MR
CKR
ENR
OE
Q17/PG2/PE2
Q16
Q15
Q14
Q11
Q12
Q13
VSS(N)
Q9
Q10
Q4
Q5
Q6
Q7
Q8/PG1/PE1
VSS
c455-3
In the standalone and width expansion configurations, a LOW
on the retransmit (RT) input causes the FIFOs to retransmit
the data. Read enable (ENR) and the write enable (ENW)
must both be HIGH during the retransmit, and then ENR is
used to access the data.When ENW is asserted, data is written into the FIFO on the rising edge of the CKW signal. While
ENW is held active, data is continually written into the FIFO on
each CKW cycle. The output port is controlled in a similar manner by a free-running read clock (CKR) and a read enable pin
(ENR). In addition, the CY7C455, CY7C456, and CY7C457
have an output enable pin (OE). The read (CKR) and write
(CKW) clocks may be tied together for single-clock operation
or the two clocks may be run independently for asynchronous
read/write applications. Clock frequencies up to 83.3 MHz are
achievable in the standalone configuration, and up to 83.3
MHz is achievable when FIFOs are cascaded for depth expansion.
Depth expansion is possible using the cascade input (XI), cascade output (XO), and First Load (FL) pins. The XO pin is
connected to the XI pin of the next device, and the XO pin of
the last device should be connected to the XI pin of the first
device. The FL pin of the first device is tied to VSS.
The CY7C455, CY7C456, and CY7C457 provide three status
pins. These pins are decoded to determine one of six states:
Empty, Almost Empty, Less than or Equal to Half Full, Greater
than Half Full, Almost Full, and Full (see Table 1). The Almost
Empty/Full flag (PAFE) shares the XO pin on the CY7C455,
CY7C456, and CY7C457. This flag is valid in the standalone
and width-expansion configurations. In the depth expansion,
this pin provides the expansion out (XO) information that is
used to signal the next FIFO when it will be activated.
The flags are synchronous, i.e., they change state relative to
either the read clock (CKR) or the write clock (CKW). When
entering or exiting the Empty and Almost Empty states, the
flags are updated exclusively by the CKR. The flags denoting
Half Full, Almost Full, and Full states are updated exclusively
by CKW. The synchronous flag architecture guarantees that
the flags maintain their status for some minimum time. This
time is typically equal to approximately one cycle time.
The CY7C455/6/7 uses center power and ground for reduced
noise. All configurations are fabricated using an advanced
0.65u CMOS technology. Input ESD protection is greater
than 2001V, and latch-up is prevented by the use of guard
rings.
Document #: 38-06003 Rev. **
Page 2 of 23
CY7C455
CY7C456
CY7C457
Selection Guide
7C455/6/7–12
7C455/6/7–14
7C455/6/7–20
7C455/6/7–30
Maximum Frequency (MHz)
83.3
71.4
50
33.3
Maximum Cascadable Frequency
83.3
71.4
50
33.3
Maximum Access Time (ns)
9
10
15
20
Minimum Cycle Time (ns)
12
14
20
30
Minimum Clock HIGH Time (ns)
5
6.5
9
12
Minimum Clock LOW Time (ns)
5
6.5
9
12
Minimum Data or Enable Set-Up (ns)
4
5
6
7
Minimum Data or Enable Hold (ns)
0
0
0
0
Maximum Flag Delay (ns)
Maximum Current
(mA)
9
10
15
20
Commercial
160
160
140
120
Industrial
180
180
160
140
Selection Guide (continued)
Density
OE, Depth Cascadable
Package
CY7C455
CY7C456
CY7C457
512 x 18
1,024 x 18
2,048 x 18
Yes
Yes
Yes
52-Pin PLCC/PQFP
52-Pin PLCC/PQFP
52-Pin PLCC/PQFP
Maximum Ratings
Static Discharge Voltage ........................................... >2001V
(per MIL-STD-883, Method 3015)
(Above which the useful life may be impaired. For user guidelines, not tested.)
Latch-Up Current..................................................... >200 mA
Storage Temperature ................................–65°C to +150 °C
Operating Range
Ambient Temperature with
Power Applied............................................–55°C to +125 °C
Supply Voltage to Ground Potential ............... –0.5V to +7.0V
Range
Ambient
Temperature
VCC
Commercial
0° C to +70 °C
5V ± 10%
–40°C to +85°C
5V ± 10%
DC Voltage Applied to Outputs
in High Z State ............................................... –0.5V to +7.0V
Industrial
DC Input Voltage............................................ –3.0V to +7.0V
Note:
1. TA is the “instant on” case temperature.
Output Current into Outputs (LOW) .............................20 mA
Document #: 38-06003 Rev. **
[1]
Page 3 of 23
CY7C455
CY7C456
CY7C457
Pin Definitions
I/O
Description
D0 − 17
Signal Name
I
Data Inputs: When the FIFO is not full and ENW is active, CKW (rising edge) writes data (D 0 − 17) into
the FIFO’s memory. If MR is asserted at the rising edge of CKW, data is written into the FIFO’s
programming register. D8, 17 are ignored if the device is configured for parity generation.
Q0 − 7
Q9 − 16
O
Data Outputs: When the FIFO is not empty and ENR is active, CKR (rising edge) reads data (Q0 − 7,
Q9 − 16) out of the FIFO’s memory. If MR is active at the rising edge of CKR, data is read from the
programming register.
Q8/PG1/PE1
Q17/PG2/PE2
O
Function varies according to mode:
Parity disabled – same function as Q0 − 7 and Q9 − 16
Parity enabled, generation – parity generation bit (PG x)
Parity enabled, check – Parity Error Flag (PEx)
ENW
I
Enable Write: Enables the CKW input (for both non-program and program modes).
ENR
I
Enable Read: Enables the CKR input (for both non-program and program modes).
CKW
I
Write Clock: The rising edge clocks data into the FIFO when ENW is LOW; updates Half Full, Almost
Full, and Full flag states. When MR is asserted, CKW writes data into the program register.
CKR
I
Read Clock: The rising edge clocks data out of the FIFO when ENR is LOW; updates the Empty and
Almost Empty flag states. When MR is asserted, CKR reads data out of the program register.
HF
O
Half Full Flag: Synchronized to CKW.
E/F
O
Empty or Full Flag: E is synchronized to CKR; F is synchronized to CKW.
PAFE/XO
O
Dual-Mode Pin:
Not Cascaded – programmable Almost Full is synchronized to CKW; Programmable Almost Empty is
synchronized to CKR.
Cascaded – expansion out signal, connected to XI of next device.
XI
I
Expansion-In Pin:
Not Cascaded – XI is tied to VSS.
Cascaded – expansion Input, connected to XO of previous device.
FL/RT
I
First Load/Retransmit Pin:
Cascaded – the first device in the daisy chain will have FL tied to VSS; all other devices will have FL tied
to VCC (Figure 1).
Not Cascaded – tied to VCC.
Retransmit function is also available in standalone mode by strobing RT.
MR
I
Master Reset: Resets device to empty condition.
Non-Programming Mode: Program register is reset to default condition of no parity and PAFE active at
16 or less locations from Full/Empty.
Programming Mode: Data present on D0 - 9,10, or 11 and D15-17 is written into the programmable register
on the rising edge of CKW. Program register contents appear on Q0 - 9,10, or 11 and Q15-17 after the rising
edge of CKR.
OE
I
Output Enable for Q0 − 7, Q 9 − 16, Q8/PG1/PE1 and Q 17/PG2/PE2 pins.
Document #: 38-06003 Rev. **
Page 4 of 23
CY7C455
CY7C456
CY7C457
Electrical Characteristics Over the Operating Range
Parameter
7C455/6/7– 7C455/6/7– 7C455/6/7–
14
20
30
Min.
Test Conditions
Min.
VOH
Output HIGH
Voltage
VCC = Min., IOH = –2.0 mA
2.4
VOL
Output LOW
Voltage
VCC = Min., I OL = 8.0 mA
VIH[2]
Input HIGH Voltage
[2]
Input LOW Voltage
VIL
Description
7C455/6/7–
12
Max
0.4
2.2
Max
2.4
Min.
2.2
Min.
2.2
VCC
2.2
Unit
V
0.4
VCC
Max
2.4
0.4
VCC
Max
2.4
0.4
V
VCC
V
–0.5
0.8
–0.5
0.8
–0.5
0.8
–0.5
0.8
V
IIX
Input Leakage
Current
VCC = Max.
–10
+10
–10
+10
–10
+10
–10
+10
µA
IOS[3]
Output Short
Circuit Current
VCC = Max., VOUT = GND
–90
IOZL
IOZH
Output OFF, High Z
Current
OE > VIH, VSS < VO < VCC
–10
ICC1[4]
Operating Current
VCC = Max.,
IOUT = 0 mA
Com’l
160
160
Ind
180
ICC2[5]
Operating Current
VCC = Max.,
IOUT = 0 mA
Com’l
90
Ind
VCC = Max.,
IOUT = 0 mA
ISB
[6]
Standby Current
–90
–90
–90
mA
+10
µA
140
120
mA
180
160
140
mA
90
90
90
mA
100
100
100
100
mA
Com’l
40
40
40
40
mA
Ind
40
40
40
40
mA
+10
–10
+10
–10
+10
–10
Capacitance[7]
Parameter
Description
CIN
Input Capacitance
COUT
Output Capacitance
Test Conditions
TA = 25° C, f = 1 MHz,
VCC = 5.0V
Max.
Unit
10
pF
12
pF
AC Test Loads and Waveforms[8, 9, 10, 11, 12]
R1 500 Ω
5V
ALL INPUT PULSES
OUTPUT
3.0V
CL
R2
333Ω
INCLUDING
JIG AND
SCOPE
Equivalent to:
THÉVENIN EQUIVALENT
200Ω
OUTPUT
c455-4
GND
≤ 3 ns
90%
10%
90%
10%
≤ 3 ns
c455-5
2V
Notes:
2. The VIH and VIL specifications apply for all inputs except XI. The XI pin is not a TTL input. It is connected to either XO of the previous device or V SS.
3. Test no more than one output at a time for not more than one second.
4. Input signals switch from 0V to 3V with a rise/fall time of less than 3 ns, clocks and clock enables switch at maximum frequency (fMAX), while data inputs
switch at fMAX/2. Outputs are unloaded.
5. Input signals switch from 0V to 3V with a rise/fall time less than 3 ns, clocks and clock enables switch at 20 MHz, while the data inputs switch at 10 MHz.
Outputs are unloaded.
6. All input signals are connected to VCC . All outputs are unloaded. Read and write clocks switch at maximum frequency (fMAX).
7. Tested initially and after any design or process changes that may affect these parameters.
8. CL = 30 pF for all AC parameters except for tOHZ .
9. CL = 5 pF for t OHZ .
10. All AC measurements are referenced to 1.5V except tOE, t OLZ , and t OHZ .
11. tOE and t OLZ are measured at ± 100 mV from the steady state.
12. tOHZ is measured at +500 mV from VOL and – 500 mV from VOH .
Document #: 38-06003 Rev. **
Page 5 of 23
CY7C455
CY7C456
CY7C457
Switching Characteristics Over the Operating Range[13]
7C455/6/7– 7C455/6/7– 7C455/6/7–
12
14
20
Parameter
Description
7C455/6/7–
30
Min. Max. Min. Max. Min. Max. Min. Max.
Unit
tCKW
Write Clock Cycle
12
14
20
30
ns
tCKR
Read Clock Cycle
12
14
20
30
ns
tCKH
Clock HIGH
5
6.5
9
12
ns
tCKL
Clock LOW
5
6.5
9
12
ns
tA
Data Access Time
tOH
Previous Output Data Hold After Read HIGH
0
0
0
0
ns
tFH
Previous Flag Hold After Read/Write HIGH
0
0
0
0
ns
tSD
Data Set-Up
4
5
6
7
ns
tHD
Data Hold
0
0
0
0
ns
tSEN
Enable Set-Up
4
5
6
7
ns
tHEN
Enable Hold
0
tOE
OE LOW to Output Data Valid
9
10
0
9
15
0
10
20
0
15
ns
ns
20
ns
[7, 14]
OE LOW to Output Data in Low Z
[7, 14]
OE HIGH to Output Data in High Z
9
10
15
20
ns
tPG
Read HIGH to Parity Generation
9
10
15
20
ns
tPE
Read HIGH to Parity Error Flag
9
10
15
20
ns
Flag Delay
9
10
15
20
ns
tOLZ
tOHZ
tFD
0
0
0
0
ns
tSKEW1
[15]
Opposite Clock After Clock
0
0
0
0
ns
tSKEW2
[16]
Opposite Clock Before Clock
12
14
20
30
ns
tPMR
Master Reset Pulse Width (MR LOW)
14
14
20
30
ns
tSCMR
Last Valid Clock LOW Set-Up to MR LOW
0
0
0
0
ns
tOHMR
Data Hold From MR LOW
0
0
0
0
ns
tMRR
Master Reset Recovery
(MR HIGH Set-Up to First Enabled Write/Read)
12
14
20
30
ns
tMRF
MR HIGH to Flags Valid
tAMR
MR HIGH to Data Outputs LOW
tSMRP
Program Mode—MR LOW Set-Up
12
14
20
30
ns
tHMRP
Program Mode—MR LOW Hold
9
10
15
20
ns
tFTP
Program Mode—Write HIGH to Read HIGH
12
14
20
30
ns
tAP
Program Mode—Data Access Time
tOHP
Program Mode—Data Hold Time from MR HIGH
0
0
0
0
ns
tPRT
Retransmit Pulse Width
12
14
20
30
ns
tRTR
Retransmit Recovery Time
12
14
20
30
ns
12
14
12
20
14
12
20
14
20
30
ns
30
ns
30
ns
13. Test conditions assume signal transition time of 3 ns or less, timing reference levels of 1.5V, and output loading as shown in AC Test Loads and
Waveforms and capacitance as in notes 8 and 9, unless otherwise specified.
14. At any given temperature and voltage condition, tOLZ is greater than tOHZ for any given device.
15. tSKEW1 is the minimum time an opposite clock can occur after a clock and still be guaranteed not to be included in the current clock cycle
(for purposes of flag update). If the opposite clock occurs less than tSKEW1 after the clock, the decision of whether or not to include the
opposite clock in the current clock cycle is arbitrary. Note: The opposite clock is the signal to which a flag is not synchronized; i.e., CKW is
the opposite clock for Empty and Almost Empty flags, CKR is the opposite clock for the Almost Full, Half Full, and Full flags. The clock is the signal
to which a flag is synchronized; i.e., CKW is the clock for the Half Full, Almost Full, and Full flags, CKR is the clock for Empty and Almost Empty flags.
16. tSKEW2 is the minimum time an opposite clock can occur before a clock and still be guaranteed to be included in the current clock cycle (for
purposes of flag update). If the opposite clock occurs less than tSKEW2 before the clock, the decision of whether or not to include the opposite
clock in the current clock cycle is arbitrary. See Note 15 for definition of clock and opposite clock.
Document #: 38-06003 Rev. **
Page 6 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms
tCKW
Write Clock Timing Diagram
tCKH
CKW
tCKL
ENABLED WRITE
tSD
D0 − 17
DISABLED WRITE
tHD
VALID DATA IN
tSEN
tHEN
ENW
tSEN
tFH
tHEN
E/F,PAFE,HF
tFH
tFD
Read Clock Timing Diagram
tCKR
tCKH
CKR
c455-6
tCKL
ENABLED READ
DISABLED READ
tA
tOH
Q0 − 17
tFD
PREVIOUS WORD
NEW WORD
tSEN
tHEN
ENR
tSEN
tFH
tHEN
E/F,PAFE
tFH
tFD
tFD
c455-7
[17, 18, 19, 20]
MasterReset (Defaultwith Free-RunningClocks) Timing Diagram
tPMR
MR
tSCMR
CKW
tMRR
FIRST
WRITE
ENW
tSCMR
tMRR
CKR
ENR
tOHMR
Q0 − 17
tAMR
ALL DATA
OUTPUTS LOW
VALID DATA
tMRF
E/F,PAFE
tMRF
HF
c455-8
Notes:
17. To only perform reset (no programming), the following criteria must be met: ENW or CKW must be inactive while MR is LOW.
18. To only perform reset (no programming), the following criteria must be met: ENR or CKR must be inactive while MR is LOW.
19. All data outputs (Q0 - 17) go LOW as a result of the rising edge of MR after t AMR .
20. In this example, Q0 - 17 will remain valid until tOHMR if either the first read shown did not occur or if the read occurred soon enough such that the valid
data was caused by it.
Document #: 38-06003 Rev. **
Page 7 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
[19, 20]
Master Reset (Programming Mode) Timing Diagram
tSMRP
tHMRP
MR
tSCMR
CKW
ENW
tCKH
tMRR
LAST
VALID
WRITE
PGM
WRITE
tHD
LAST
WORD
PGM
WORD
tSCMR
CKR
ENR
WORD 1
tSMRP
WORD 2
tHMRP
LAST
VALID
READ
PGM
READ
tCKH
LOW
tOHMR
Q0 − 17
SECOND
WRITE
tFTP
LOW
tSD
D0 − 17
FIRST
WRITE
tAP
VALID DATA
tOHP
tAMR
ALL DATA
OUTPUTS LOW
PGM WORD
c455-9
[19, 20]
Master Reset (Programming Mode with Free-Running Clocks) Timing Diagram
tSMRP
tHMRP
tCKW
MR
tSCMR
CKW
tCKH
LAST
VALID
WRITE
tCKL
tMRR
PGM
WRITE
tSEN
FIRST
WRITE
SECOND
WRITE
tHEN
ENW
tFTP
D0 − 17
LAST
WORD
PGM
WORD
WORD 1
WORD 2
tCKR
tSCMR
CKR
tSMRP
tMRR
tHMRP
PGM
READ
LAST
VALID
READ
tCKH
tSEN
tCKL
tHEN
ENR
tOHMR
Q0 − 17
VALID DATA
tAP
tOHP
PGM WORD
tAMR
ALL DATA
OUTPUTS LOW
c455-10
Document #: 38-06003 Rev. **
Page 8 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
[21, 24, 25]
Read to Empty Timing Diagram
COUNT
3
1
2
1
0
1 (NO CHANGE)
0
LATENT CYCLE
R1
ENABLED
READ
CKR
R2
ENABLED
READ
R3
ENABLED
READ
R4
FLAG
UPDATE
READ
R5
ENABLED
READ
tFD
tFD
ENR
tSKEW1
CKW
ENW
tSKEW2
W1
ENABLED
WRITE
LOW
tFD
E/F
c455-12
[21, 22, 23, 24]
Read to Empty Timing Diagram with Free-RunningClocks
COUNT
1
CKR
0
LATENT CYCLE
1
R1
ENABLED
READ
R2
IGNORED
READ
R3
IGNORED
READ
tSKEW2
R4
FLAG
UPDATE
READ
0
R5
ENABLED
READ
R6
IGNORED
READ
ENR
tSKEW1
CKW
W1
W2
tSKEW2
W3
ENABLED
WRITE
W4
W5
W6
ENW
HF
HIGH
tFD
tFD
tFD
E/F
PAFE
LOW
c455-11
Notes:
21. “Count” is the number of words in the FIFO.
22. The FIFO is assumed to be programmed with P>0 (i.e., PAFE does not transition at Empty or Full).
23. R2 is ignored because the FIFO is empty (count = 0). It is important to note that R3 is also ignored because W3, the first enabled write after empty, occurs
less than tSKEW2 before R3. Therefore, the FIFO still appears empty when R3 occurs. Because W3 occurs greater than t SKEW2 before R4, R4 includes
W3 in the flag update.
24. CKR is clock and CKW is opposite clock.
25. R3 updates the flag to the Empty state by asserting E/F. Because W1 occurs greater than t SKEW1 after R3, R3 does not recognize W1 when updating
flag status. But because W1 occurs tSKEW2 before R4, R4 includes W1 in the flag update and, therefore, updates FIFO to Almost Empty state. It is
important to note that R4 is a latent cycle; i.e., it only updates the flag status regardless of the state of ENR. It does not change the count or the
FIFO’s data outputs.
Document #: 38-06003 Rev. **
Page 9 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
[21, 24, 26]
Read to Almost Empty Timing Diagram with Free-Running Clocks
COUNT
17
16
R1
ENABLED
READ
CKR
18
17
R2
17
R3
16
R4
ENABLED
READ
15
R5
ENABLED
READ
R6
ENABLED
READ
ENR
tSKEW1
CKW
tSKEW2
W2
ENABLED
WRITE
W1
W3
ENABLED
WRITE
W4
W5
W1
W6
ENW
HF
HIGH
E/F
HIGH
tFD
tFD
tFD
PAFE
c455-14
Read to Almost Empty Timing Diagram with Read Flag Update Cycle with Free-Running Clocks
[21, 24, 26, 27, 28]
18 (no change)
COUNT
17
CKR
17
16
R1
ENABLED
READ
FLAG UPDATE CYCLE
18
R2
R3
R4
FLAG
UPDATE
READ
17
16
15
R5
ENABLED
READ
R6
ENABLED
READ
R7
ENABLED
READ
W5
W6
W7
ENR
tSKEW1
CKW
tSKEW2
W2
ENABLED
WRITE
W1
W3
ENABLED
WRITE
W4
ENW
HF
HIGH
E/F
HIGH
tFD
tFD
tFD
PAFE
c455-13
Notes:
26. The FIFO in this example is assumed to be programmed to its default flag values. Almost Empty is 16 words from Empty; Almost Full is 16 locations from Full.
27. R4 only updates the flag status. It does not affect the count because ENR is HIGH.
28. When making the transition from Almost Empty to Intermediate, the count must increase by two (16 Á 18; two enabled writes: W2, W3) before a read (R4)
can update flags to the Less Than Half Full state.
Document #: 38-06003 Rev. **
Page 10 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
[21, 29, 30, 31]
Write to Half Full Timing Diagram with Free-Running Clocks
1024
[512]
[256]
COUNT
1025
[513]
[257]
CKW
W1
ENABLED
WRITE
1024
[512]
[256]
1023
[511]
[255]
W2
W3
1024
[512]
[256]
1025
[513]
[257]
W4
ENABLED
WRITE
1026
[514]
[258]
W6
ENABLED
WRITE
W5
ENABLED
WRITE
ENW
tSKEW1
CKR
tSKEW2
R2
ENABLED
READ
R1
R3
ENABLED
READ
R4
R5
R6
ENR
tFD
tFD
tFD
HF
E/F
HIGH
PAFE
HIGH
c455-15
Write to Half Full Timing Diagram with Write Flag Update Cycle with Free-Running Clocks
1024
COUNT [512]
[256]
CKW
1025
[513]
[257]
1024
[512]
[256]
1023
[511]
[255]
W2
W3
W1
ENABLED
WRITE
1023 [511]
[255] (no change)
FLAG UPDATE CYCLE
1024
[512]
[256]
W4
FLAG
UPDATE
WRITE
W5
ENABLED
WRITE
R4
R5
[21, 29, 30, 31, 32, 33]
1025
[513]
[257]
1026
[514]
[258]
W6
ENABLED
WRITE
W7
ENABLED
WRITE
ENW
tSKEW1
CKR
tSKEW2
R2
ENABLED
READ
R1
R3
ENABLED
READ
R6
R7
ENR
tFD
tFD
tFD
HF
E/F
HIGH
PAFE
HIGH
c455–16
Notes:
29. CKW is clock and CKR is opposite clock.
30. Count = 1,025 indicates Half Full for the CY7C446 and CY7C456. Count = 513 indicates Half Full for the CY7C447 and CY7C457. Count = 257 indicates
Half Full for the CY7C448 and CY7C458.
31. When the FIFO contains 1,024 [512] [256] words, the rising edge of the next enabled write causes the HF to be true (LOW).
32. The HF write flag update cycle does not affect the count because ENW is HIGH. It only updates HF to HIGH.
33. When making the transition from Half Full to Less Than Half Full, the count must decrease by two (i.e., 1,025 Á 1,023; two enabled reads: R2 and R3)
before a write (W4) can update flags to less than Half Full.
Document #: 38-06003 Rev. **
Page 11 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
Write to Almost Full Timing Diagram
COUNT
2030
[1016]
[494]
CKW
2031
[1017]
[495]
[21, 26, 29, 34, 35]
2032
[1018]
[496]
W1
ENABLED
WRITE
2031
[1017]
[495]
2030
[1016]
[494]
W2
ENABLED
WRITE
2031 [1017]
[495]
2032
[496]
2033
[497]
2030 [1016]
[494]
2031 [1017]
[495]
2032 [1018]
[496]
W4
ENABLED
WRITE
W5
ENABLED
WRITE
W3
ENABLED
WRITE
FLAG UPDATE
ENW
LOW
tSKEW1
tSKEW2
R1
ENABLED
READ
CKR
ENR
R2
ENABLED
READ
LOW
tFD
tFD
tFD
tFD
PAFE
HF
LOW
E/F
HIGH
c455-18
[21, 26, 29]
Write to Almost Full Timing Diagram with Free-RunningClocks
COUNT
2031
[1017]
[495]
CKW
2032
[1018]
[496]
W1
ENABLED
WRITE
2031
[1017]
[495]
W2
2030
[1016]
[494]
W3
2031
[1017]
[495]
W4
ENABLED
WRITE
2032
[1018]
[496]
2033
[1019]
[497]
W5
ENABLED
WRITE
W6
ENABLED
WRITE
ENW
tSKEW1
CKR
tSKEW2
R2
ENABLED
READ
R1
R3
ENABLED
READ
R4
R6
R5
ENR
HF
LOW
E/F
HIGH
tFD
tFD
tFD
PAFE
c455-17
Notes:
34. W2 updates the flag to the Almost Full state by asserting PAFE. Because R1 occurs greater than t SKEW1 after W2, W2 does not recognize R1 when
updating flag status. W3 includes R2 in the flag update because R2 occurs greater than tSKEW2 before W3. Note that W3 does not have to be enabled
to update flags.
35. The dashed lines show W3 as a flag update write rather than an enabled write because ENW is HIGH.
Document #: 38-06003 Rev. **
Page 12 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
Write to Almost Full Timing Diagram with Write Flag Update Cycle and Free-Running Clocks
[21, 26, 29]
2030 [1016]
[494] (no change)
2031
COUNT [1017]
[495]
CKW
2031
[1017]
[495]
2032
[1018]
[496]
W1
ENABLED
WRITE
2030
[1016]
[494]
W2
FLAG UPDATE CYCLE
W3
W4
FLAG
UPDATE
WRITE
2031
[1017]
[495]
2033
[1019]
[497]
2032
[1018]
[496]
W5
ENABLED
WRITE
W6
ENABLED
WRITE
W7
ENABLED
WRITE
R5
R6
R7
ENW
tSKEW1
CKR
tSKEW2
R1
R2
ENABLED
READ
R4
R3
ENABLED
READ
ENR
HF
LOW
E/F
HIGH
tFD
tFD
tFD
PAFE
c455-19
Write to Full Flag Timing Diagram with Free-Running Clocks
COUNT
2047
[1023]
[511]
2048
[1024]
[512]
2048
[1024]
[512]
W1
ENABLED
WRITE
CKW
W2
IGNORED
WRITE
[21, 29, 36]
LATENT CYCLE
2047
[1023]
[511]
W3
IGNORED
WRITE
tSKEW2
W4
FLAG
UPDATE
WRITE
2048
[1024]
[512]
W5
ENABLED
WRITE
2048
[1024]
[512]
W6
IGNORED
WRITE
ENW
tSKEW1
CKR
tSKEW2
R2
R1
R3
ENABLED
READ
R4
R6
R5
ENR
HF
LOW
tFD
tFD
tFD
E/F
PAFE
LOW
c455-20
Note:
36. W2 is ignored because the FIFO is full (count = 2,048 [1,024] [512]). It is important to note that W3 is also ignored because R3, the first enabled read after
full, occurs less than tSKEW2 before W3. Therefore, the FIFO still appears full when W3 occurs. Because R3 occurs greater than tSKEW2 before W4,
W4 includes R3 in the flag update.
Document #: 38-06003 Rev. **
Page 13 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
Even Parity Generation Timing Diagram
CKR
[37, 38]
ENABLED READ
DISABLED READ
tPG
PE1, (PE2)
Q0− 7
(Q9 − 16)
PREVIOUS WORD:
EVEN NUMBER OF 1s
NEW WORD:
ODD NUMBER OF 1s
ENR
c455-21
Even Parity GenerationTiming Diagram
CKR
ENABLED READ
DISABLED READ
tPG
PE1, (PE2)
Q0− 7
(Q9 − 16)
[37, 39]
PREVIOUS WORD:
ODD NUMBER OF 1s
NEW WORD:
EVEN NUMBER OF 1s
ENR
c455-22
Notes:
37. In this example, the FIFO is assumed to be programmed to generate even parity. The Q0−7 word is shown. The example is similar for the Q9-16 word.
38. If Q0−7 “new word” also has an even number of 1s, then PG1 stays LOW.
39. If Q0−7 “new word” also has odd number of 1s, then PG1 stays HIGH.
Document #: 38-06003 Rev. **
Page 14 of 23
CY7C455
CY7C456
CY7C457
Switching Waveforms (continued)
Even Par ity Checking
[40]
CKW
WRITE M
WRITE M+1
WRITE M+2
ENW
WORD M:
WORD M+ 1:
ODD NUMBER
OF 1“ s
D0− 7 EVEN NUMBER
OF 1“ s
WORD M+ 2:
EVEN NUMBER
OF 1“s
CKR
READ M
READ M+1
READ M+2
ENR
tPE
tPE
F1
PE1
(PE2)
8 LSBs OF
WORD M-1
Q0− 7
(Q9− 16)
8 LSBs OF
WORD M
8 LSBs OF
WORD M+1
8 LSBs OF
WORD M+2
c455-23
[41, 42]
Output Enable Timing
CKR
ENR
READ M+1
LOW
OE
tOHZ
Q0− 17
tOE
VALID DATA
WORD M
VALID DATA
WORD M+1
tOLZ
c455–24
[43, 44]
Retransmit Timing
FL/RT
tPRT
tRTR
REN/WEN
E/F, HF, PAFE
42X5–21
Notes:
40. In this example, the FIFO is assumed to be programmed to check for even parity. The Q0-7 word is shown.
41. This example assumes that the time from the CKR rising edge to valid word M+1 > tA. The Q 0-7 word is shown.
42. If ENR was HIGH around the rising edge of CKR (i.e., read disabled), the valid data at the far right would once again be word M instead of word M+1.
43. Clocks are free running in this case.
44. The flags may change state during Retransmit as a result of the offset of the read and write pointers, but flags will be valid at tRTR.
Document #: 38-06003 Rev. **
Page 15 of 23
CY7C455
CY7C456
CY7C457
Architecture
The CY7C455/6/7 consists of an array of 512, 1024, or 2048
words of 18 bits each (implemented by a dual-port array of
SRAM cells), a read pointer, a write pointer, control signals
(CKR, CKW, ENR, ENW, and MR), and flags (HF, E/F, PAFE).
The CY7C455/6/7 also includes the control signals OE, FL, XI,
and XO for depth expansion.
Resetting the FIFO
Upon power-up, the FIFO must be reset with a Master Reset
(MR) cycle. This causes the FIFO to enter the Empty condition
signified by E/F and PAFE being LOW and HF being HIGH. All
data outputs (Q0−17) go low at the rising edge of MR. In order
for the FIFO to reset to its default state, a falling edge must
occur on MR and the user must not read or write while MR is
LOW (unless ENR and ENW are HIGH or unless the device is
being programmed). Upon completion of the master reset cycle, all data outputs will go LOW tAMR after MR is deasserted.
All flags are guaranteed to be valid tMRF after MR is taken
HIGH.
FIFO Operation
When the ENW signal is active (LOW), data present on the
D0 − 17 pins is written into the FIFO on each rising edge of the
CKW signal. Similarly, when the ENR signal is active, data in
the FIFO memory will be presented on the Q0−17 outputs. New
data will be presented on each rising edge of CKR while ENR
is active. ENR must set up tSEN before CKR for it to be a valid
read. ENW must occur tSEN before CKW for it to be a valid
write.
An output enable (OE) pin is provided to three-state the Q0−17
outputs when OE is asserted. When OE is enabled (low), data
in the output register will be available to the Q0−17 outputs after
tOE. If devices are cascaded, the OE function will only output
data on the FIFO that is read enabled.
The FIFO contains overflow circuitry to disallow additional
writes when the FIFO is full, and underflow circuitry to disallow
additional reads when the FIFO is empty. An empty FIFO
maintains the data of the last valid read on its Q0–17 outputs
even after additional reads occur.
Programming
The CY7C455/6/7 is programmed during a master reset cycle.
If MR and ENW are LOW, a rising edge on CKW will write the
D0−7,8,or9 and D15–17 inputs into the programming register[45].
MR must be set up a minimum of tSMRP before the program
write rising edge and held tHMRP after the program write falling
edge. The user has the ability to also perform a program read
during the master reset cycle. This will occur at the rising edge
of CKR when MR and ENR are asserted. The program read
must be performed a minimum of tFTP after a program write,
and the program word will be available tAP after the read occurs. If a program write does not occur, a program read may
occur a minimum of tSMRP after MR is asserted. This will read
the default program value.
When free-running clocks are tied to CKW and CKR, programming can still occur during a master reset cycle with the adherence to a few additional timing parameters. The enable pins
must be set-up tSEN before the rising edge of CKW or CKR.
Hold times of tHEN must also be met for ENW and ENR.
Data present on D0−9 during a program write will determine the
distance from Empty (Full) that the Almost Empty (Almost Full)
flags will become active. See Table 1 for a description of the
six possible FIFO states. P in Table 1 refers to the decimal
equivalent of the binary number represented by D0−7, 8 or 9.
Programming options for the CY7C455/6/7 are listed in
Table 4.
The programmable PAFE function on the CY7C455/6/7 is only
valid when not cascaded. If the user elects not to program the
FIFO’s flags, the default is as follows: the Almost Empty condition (Almost Full condition) is activated when the FIFO contains 16 or less words (empty locations).
Parity is programmed with the D15−17 bits. See Table 4 for a
summary of the various parity programming options. Data
present on D15−17 during a program write will determine
whether the FIFO will generate or check even/odd parity for
the data present on D0−7 and D9−16 thereafter. If the user
elects not to program the FIFO, the parity function is disabled.
Flag operation and parity are described in greater detail in subsequent sections.
Flag Operation
The CY7C455/6/7 provides three status pins when not cascaded. The three pins, E/F, PAFE, and HF, allow decoding of
six FIFO states (Table 1). PAFE is not available when the
CY7C455/6/7 is cascaded for depth expansion. All flags are
synchronous, meaning that the change of states is relative to
one of the clocks (CKR or CKW, as appropriate).[46] The Empty and Almost Empty flag states are exclusively updated by
each rising edge of the read clock (CKR). For example, when
the FIFO contains 1 word, the next read (rising edge of CKR
while ENR=LOW) causes the flag pins to output a state that
represents Empty. The Half Full, Almost Full, and Full flag
states are updated exclusively by the write clock (CKW). For
example, if the CY7C457 contains 2,047 words (2,048 words
indicate Full for the CY7C457), the next write (rising edge of
CKW while ENW=LOW) causes the flag pins to output a state
that is decoded as Full.
Since the flags denoting emptiness (Empty, Almost Empty) are
only updated by CKR and the flags signifying fullness (Half
Full, Almost Full, Full) are exclusively updated by CKW, careful
attention must be given to the flag operation. The user must
be aware that if a boundary (Empty, Almost Empty, Half Full,
Almost Full, or Full) is crossed due to an operation from a clock
that the flag is not synchronized to (i.e., CKW does not affect
Empty or Almost Empty), a flag update cycle is necessary to
represent the FIFO’s new state. The signal to which a flag is
not synchronized will be referred to as the opposite clock
(CKW is opposite clock for Empty and Almost Empty flags;
CKR is the opposite clock for Half Full, Almost Full, and Full
flags). Until a proper flag update cycle is executed, the synchronous flags will not show the new state of the FIFO.
Notes:
45. CKW will write D0–9 into the programming register. CKR will read D0–9 during a programming register read.
46. The synchronous architecture guarantees the flags valid for approximately one cycle of the clock they are synchronized to.
Document #: 38-06003 Rev. **
Page 16 of 23
CY7C455
CY7C456
CY7C457
When updating flags, the FIFO must make a decision as to
whether or not the opposite clock was recognized when a
clock updates the flag. For example (when updating the Empty
flag), if a write occurs at least tSKEW1 after a read, the write is
guaranteed not to be included when CKR updates the flag. If
a write occurs at least tSKEW2 before a read, the write is guaranteed to be included when CKR updates flag. If a write occurs
within tSKEW1 after or tSKEW2 before CKR, then the decision of
whether or not to include the write when the flag is updated by
CKR is arbitrary.
The update cycle for non-boundary flags (Almost Empty, Half
Full, Almost Full) is different from that used to update the
boundary flags (Empty, Full). Both operations are described
below.
Boundary and Non-Boundary Flags
Boundary Flags (Empty)
The Empty flag is synchronized to the CKR signal (i.e., the
Empty flag can only be updated by a clock pulse on the CKR
pin). An empty FIFO that is written to will be described with an
Empty flag state until a rising edge is presented to the CKR
pin. When making the transition from Empty to Almost Empty
(or Empty to Less than or Equal to Half Full), a clock cycle on
CKR is necessary to update the flags to the current state. In
such a state (flags showing Empty even though data has been
written to the FIFO), two read clock cycles are required to read
data out of the FIFO. The first read serves only to update the
flags to the Almost Empty or Less than or Equal to Half Full
state, while the second read outputs the data. This first read
cycle is known as the latent or flag update cycle because it
does not affect the data in the FIFO or the count (number of
words in FIFO). It simply deasserts the Empty flag. The flag is
updated regardless of the ENR state. Therefore, the update
occurs even when ENR is deasserted (HIGH), so that a valid
read is not necessary to update the flags to correctly describe
the FIFO. In this example, the write must occur at least tSKEW2
before the flag update cycle in order for the FIFO to guarantee
that the write will be included in the count when CKR updates
the flags. When a free-running clock is connected to CKR, the
flag is updated each cycle. Table 2 shows an example of a
sequence of operations that update the Empty flag.
Boundary Flags (Full)
The Full flag is synchronized to the CKW signal (i.e., the Full
flag can only be updated by a clock pulse on the CKW pin). A
full FIFO that is read will be described with a Full flag until a
rising edge is presented to the CKW pin. When making the
transition from Full to Almost Full (or Full to Greater Than Half
Full), a clock cycle on CKW is necessary to update the flags
to the current state. In such a state (flags showing Full even
through data has been read from the FIFO), two write cycles
are required to write data into the FIFO. The first write serves
only to update the flags to the Almost Full or Greater Than Half
Full state, while the second write inputs the data. This first
write cycle is known as the latent or flag update cycle because
it does not affect the data in the FIFO or the count (number of
words in the FIFO). It simply deasserts the Full flag. The flag
is updated regardless of the ENW state. Therefore, the update
occurs even when ENW is deasserted (HIGH), so that a valid
write is not necessary to update the flags to correctly describe
the FIFO. In this example, the read must occur at least tSKEW2
before the flag update cycle in order for the FIFO to guarantee
that the read will be included in the count when CKW updates
the flags. When a free-running clock is connected to CKW, the
flag updates each cycle. Full flag operation is similar to the
Empty flag operation described in Table 2.
Non-Boundary Flags (Almost Empty, Half Full, Almost Full)
The CY7C455/6/7 features programmable Almost Empty and
Almost Full flags. Each flag can be programmed a specific
distance from the corresponding boundary flags (Empty or
Full). The flags can be programmed to be activated at the
Empty or Full boundary, or at any distance from the Empty/Full
boundary. When the FIFO contains the number of words or
fewer for which the flags have been programmed, the PAFE
flag will be asserted signifying that the FIFO is Almost Empty.
When the FIFO is within that same number of empty locations
from being Full, the PAFE will also be asserted signifying that
the FIFO is Almost Full. The HF flag is decoded to distinguish
the states.
The default distance from where PAFE becomes active to the
boundary (Empty, Full) is 16 words/locations. The Almost Full
and Almost Empty flags can be programmed so that they are
only active at Full and Empty boundaries. However, the operation will remain consistent with the non-boundary flag operation that is discussed below.
.
Table 1. Flag Truth Table[47]
E/F
0
1
1
1
1
0
PAFE
0
0
1
1
0
0
HF
1
1
1
0
0
0
State
Empty
Almost Empty
Less than or Equal to Half Full
Greater than Half Full
Almost Full
Full
7C455
Words in FIFO
0
1 => P
P + 1 => 256
257 => 511 – P
512 – P => 511
512
7C456
Words in FIFO
7C457
Words in FIFO
0
1 => P
P + 1 => 512
513 => 1023 – P
1024 – P => 1023
1024
0
1 => P
P + 1 => 1024
1025 => 2047 – P
2048 – P => 2047
2048
Notes:
47. P is the decimal value of the binary number represented by D0–7 for the CY7C455, D0–8 for the CY7C456, and D 0–9 for the CY7C457. P = 0 signifies that
the Almost Empty state = Empty state.
Document #: 38-06003 Rev. **
Page 17 of 23
CY7C455
CY7C456
CY7C457
Table 2. Empty Flag (Boundary Flag) Operation Example
Status Before Operation
Status After Operation
E/F
AFE
HF
Number
of
Words
in FIFO
E/F
AFE
HF
Number
of
Words
in FIFO
Empty
0
0
1
0
Write
(ENW = 0)
Empty
0
0
1
1
Write
Empty
0
0
1
1
Write
(ENW = 0)
Empty
0
0
1
2
Write
Empty
0
0
1
2
Read
(ENR = X)
AE
1
0
1
2
Flag Update
AE
1
0
1
2
Read
(ENR = 0)
AE
1
0
1
1
Read
AE
1
0
1
1
Read
(ENR = 0)
Empty
0
0
1
0
Read (transition from
Almost Empty to Empty)
Empty
0
0
1
0
Write
(ENR = 0)
Empty
0
0
1
1
Write
Empty
1
0
1
1
Read
(ENR = X)
AE
1
0
1
1
Flag Update
AE
1
0
1
1
Read
(ENR = 0)
Empty
0
0
1
0
Read (transition from
Almost Empty to Empty)
Current
State of
FIFO
Next
State
of FIFO
Operation
Comments
Almost Empty is only updated by CKR while Half Full and Almost Full are updated by CKW. Non-boundary flags employ
flag update cycles similar to the boundary flag latent cycles in
order to update the FIFO status. For example, if the FIFO just
reaches the Greater than Half Full state, and then two words
are read from the FIFO, a write clock (CKW) will be required
to update the flags to the Less than Half Full state. However,
unlike the boundary flag latent cycle, the state of the enable
pin (ENW in this case) affects the operation. Therefore, set-up
and hold times for the enable pins must be met (tSEN and
tHEN). If the enable pin is active during the flag update cycle,
the count and data are updated in addition to PAFE and HF. If
the enable pin is not asserted during the flag update cycle, only
the flags are updated. Table 3 shows an example of a sequence of operations that update the Almost Empty and Almost Full flags
ignored. The parity bits are stored internally as D8 and D17,
and during a subsequent read will be available on the PG1
and PG2 pins along with the data words from which the
parity was generated (Q0–7 and Q9–16). For example, if parity generate is set to ODD and the D0–7 inputs have an
EVEN number of 1s, PG1 will be HIGH.
The CY7C455/6/7 also features even or odd parity checking
and generation. D15–17 are used during a program write to
describe the parity option desired. Table 4 summarizes programmable parity options. If the user elects not to program
the device, then parity is disabled. Parity information is provided on two multi-mode output pins (Q 8/PG1/PE1 and
Q17/PG2/PE2). The three possible modes are described in
the following paragraphs.
Retransmit
Programmable Parity
Parity Disabled (Q8/Q 17 mode)
When parity is disabled (or the user does not program parity
option) the FIFO stores all 18 bits present on D0–17 inputs
internally and will output all 18 bits on Q0–17.
Parity Generate (PG mode)
This mode is used to generate either even or odd parity (as
programmed) from D0–7 and D9–16. D8 and D17 inputs are
Document #: 38-06003 Rev. **
Parity Check (PE mode)
If the FIFO is programmed for parity checking, it will compare
the parity of D0–8 and D9–17 with the program register. For
example, D8 and D17 will be set according to the result of
the parity check on each word. When these words are later
read, PE1 and PE2 will reflect the result of the parity check.
If a parity error occurs in D0–8, D8 will be set LOW internally.
When this word is later read, PE1 will be LOW.
The retransmit feature is beneficial when transferring packets
of data. It enables the receipt of data to be acknowledged by
the receiver and retransmitted if necessary.
The Retransmit (RT) input is active in the standalone and width
expansion modes. The retransmit feature is intended for use
when a number of writes equal to or less than the depth of the
FIFO have occurred since the last MR cycle. A LOW pulse on RT
resets the internal read pointer to the first physical location of the
FIFO. WCLK and RCLK may be free running but must be disabled
during and tRTR after the retransmit pulse. With every valid read cycle
after retransmit, previously accessed data is read and the read pointer is incremented until it is equal to the write pointer. Flags are governed by the relative locations of the read and write pointers and are
updated during a retransmit cycle. Data written to the FIFO after activation of RT are transmitted also.
The full depth of the FIFO can be repeatedly retransmitted.
Page 18 of 23
CY7C455
CY7C456
CY7C457
Width Expansion Modes
next device, with XO of the last device connected to XI of
the first device. The first device has its first load pin (FL)
tied to VSS while all other devices must have this pin tied
to VCC. The first device will be the first to be write and read
enabled after a master reset.
During width expansion all flags (programmable and nonprogrammable) are available. These FIFOs can be expanded in
width to provide word width greater than 18 in increments of
18. During width expansion mode all control line inputs are
common. When the FIFO is being read near the Empty (Full)
boundary, it is important to note that both sets of flags should
be checked to see if they have been updated to the Not Empty
(Not Full) condition to insure that the next read (write) will perform the same operation on all devices.
Proper operation also requires that all cascaded devices have
common CKW, CKR, ENW, ENR, D0–17, Q0–17, and MR
pins. When cascaded, one device at a time will be read
enabled so as to avoid bus contention. By asserting XO
when appropriate, the currently enabled FIFO alerts the
next FIFO that it should be enabled. The next rising edge
on CKR puts Q 0–17 outputs of the first device into a high-impedance state. This occurs regardless of the state of ENR
or the next FIFO’s Empty flag. Therefore, if the next FIFO
is empty or undergoing a latent cycle, the Q 0–17 bus will be
in a high-impedance state until the next device receives its
first read, which brings its data to the Q 0–17 bus.
Checking all sets of flags is critical so that data is not read from
the FIFOs “staggered” by one clock cycle. This situation could
occur when the first write to an empty FIFO and a read are very
close together. If the read occurs less than tSKEW2 after the
first write to two width-expanded devices, A and B, device
A may go Almost Empty (read recognized as flag update)
while device B stays Empty (read ignored). This occurs
because a read can be either recognized or ignored if it
occurs within tSKEW2 of a write. The next read cycle outputs
the first half of the first word on device A while device B
updates its flags to Almost Empty. Subsequent reads will
continue to output “staggered” data assuming more data
has been written to FIFOs.
Program Write/Read of Cascaded Devices
Programming of cascaded FIFOs is the same as for a single
device. Because the controls of the FIFOs are in parallel when
cascaded, they all get programmed the same. During program
mode, only parity is programmed since Almost Full and Almost
Empty flags are not available when CY7C455/6/7 is cascaded.
Only the “first device” (FIFO with FL=LOW) will output its
program register contents on Q0–7 during a program read.
Q0–17 of all other devices will remain in a high-impedance
state to avoid bus contention.
Depth Expansion Mode
The CY7C455/6/7 can operate up to 83.3 MHz when cascaded. Depth expansion is accomplished by connecting expansion out (XO) of the first device to expansion in (XI) of the
CKW
ENW
CKR
ENR
XI
D0 – 17
Q0 – 17
CKW
CKR
CY7C455,6,7
ENW
ENR
MR
HF
OE
E/F
FL/RT
PAFE/XO
DATA OUT
DATA IN
D0– 17
MR
Q0– 17
VSS
XI
D0 – 17
Q0 – 17
CKR
CKW
CY7C455,6,7
ENW
ENR
MR
HF
FULL
E/F
OE
FL/RT
PAFE/XO
VCC
EMPTY
c455-25
Figure 1. Depth Expansion with CY7C455/6/7
Document #: 38-06003 Rev. **
Page 19 of 23
CY7C455
CY7C456
CY7C457
Table 3. Almost Empty Flag (Non-Boundary Flag) Operation Example[48]
Status Before Operation
Current
State of FIFO E/F
Status After Operation
AFE
HF
Number
of Words
in FIFO
Operation
Next State
of FIFO
E/F PAFE
HF
Number
of words
in FIFO
Comments
AE
1
0
1
32
Write
(ENW = 0)
AE
1
0
1
33
Write
AE
1
0
1
33
Write
(ENW = 0)
AE
1
0
1
34
Write
AE
1
0
1
34
Read
(ENR = 0)
<HF
1
1
1
33
Flag Update and
Read
<HF
1
1
1
33
Read
(ENR = 1)
<HF
1
1
1
33
Ignored Read
(ENR = 1)
<HF
1
1
1
33
Read
(ENR = 0)
AE
1
0
1
32
Read (transition from
<HF to AE)
Table 4. Programmable Parity Options
D17
D16
D15
Condition
0
X
X
Parity disabled.
1
0
0
Generate even parity on PG output pin.
1
0
1
Generate odd parity on PG output pin.
1
1
0
Check for even parity. Indicate error on PE output pin.
1
1
1
Check for odd parity. Indicate error on PE output pin.
Note:
48. Applies to CY7C455/6/7 operations when devices are programmed so that Almost Empty becomes active when the FIFO contains 32 or fewer words.
Document #: 38-06003 Rev. **
Page 20 of 23
CY7C455
CY7C456
CY7C457
Ordering Information
512x18 Clocked FIFO
Speed
(ns)
12
14
20
30
Package
Name
Package
Type
Operating
Range
CY7C455–12JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C455–12NC
N52
52-Pin Plastic Quad Flatpack
CY7C455–12JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C455–14JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C455–14NC
N52
52-Pin Plastic Quad Flatpack
CY7C455–14JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C455–20JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C455–20NC
N52
52-Pin Plastic Quad Flatpack
CY7C455–20JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C455–30JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C455–30NC
N52
52-Pin Plastic Quad Flatpack
CY7C455–30JI
J69
52-Lead Plastic Leaded Chip Carrier
Package
Name
Package
Type
Operating
Range
CY7C456–12JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C456–12NC
N52
52-Pin Plastic Quad Flatpack
CY7C456–12JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C456–14JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C456–14NC
N52
52-Pin Plastic Quad Flatpack
CY7C456–14JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C456–20JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C456–20NC
N52
52-Pin Plastic Quad Flatpack
CY7C456–20JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C456–30JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C456–30NC
N52
52-Pin Plastic Quad Flatpack
CY7C456–30JI
J69
52-Lead Plastic Leaded Chip Carrier
Package
Name
Package
Type
Operating
Range
CY7C457–12JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C457–12NC
N52
52-Pin Plastic Quad Flatpack
CY7C457–12JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C457–14JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C457–14NC
N52
52-Pin Plastic Quad Flatpack
CY7C457–14JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C457–20JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C457–20NC
N52
52-Pin Plastic Quad Flatpack
CY7C457–20JI
J69
52-Lead Plastic Leaded Chip Carrier
Industrial
CY7C457–30JC
J69
52-Lead Plastic Leaded Chip Carrier
Commercial
CY7C457–30NC
N52
52-Pin Plastic Quad Flatpack
CY7C457–30JI
J69
52-Lead Plastic Leaded Chip Carrier
Ordering Code
Industrial
1Kx18 Clocked FIFO
Speed
(ns)
12
14
20
30
Ordering Code
Industrial
2Kx18 Clocked FIFO
Speed
(ns)
12
14
20
30
Ordering Code
Document #: 38-06003 Rev. **
Industrial
Page 21 of 23
CY7C455
CY7C456
CY7C457
Package Diagrams
52-Lead Plastic Leaded Chip Carrier J69
52-Lead Plastic Quad Flatpack N52
Document #: 38-06003 Rev. **
Page 22 of 23
© Cypress Semiconductor Corporation, 1997. The information contained herein is subject to change without notice. Cypress Semiconductor Corporation assumes no responsibility for the use
of any circuitry other than circuitry embodied in a Cypress Semiconductor product. Nor does it convey or imply any license under patent or other rights. Cypress Semiconductor does not authorize
its products for use as critical components in life-support systems where a malfunction or failure may reasonably be expected to result in significant injury to the user. The inclusion of Cypress
Semiconductor products in life-support systems application implies that the manufacturer assumes all risk of such use and in doing so indemnifies Cypress Semiconductor against all charges.
CY7C455
CY7C456
CY7C457
Document Title: CY7C455, CY7C456, CY7C457 512 X 18, 1K X 18 and 2K X 18 Cascadable Clocked Fifo’s with Programmable Flags
Document Number: 38-06003
REV.
ECN NO.
Issue
Date
Orig. of
Change
Description of Change
**
106464
07/11/01
SZV
Change from Spec Number: 38-00211 to 38-06003
Document #: 38-06003 Rev. **