OMRON D2QW

Sealed Ultra Subminiature Basic Switch
D2QW
Sealed long stroke sliding contact switch
with reliable ON/OFF action in severe
environmental conditions.
• Extra-long stroke. (OT: 2.7 mm)
• Clip contacts with highly reliable slide contact mechanism.
• Sliding contact allows for quiet operating sound.
• High temperature resistance and drip-proof structure for
wide range of applications and environmental conditions.
• Switch body conforms to IP67
• RoHS Compliant
Ordering Information
Actuator
Terminals
Contact form
Model
Pin plunger
D2QW-C003H
Solder
Simulated roller leaf lever
SPST-NO
D2QW-C073H
Note: Contact Omron for other terminal or lever configuration and for use in automotive applications.
Model Number Legend:
D2QW1 2 3 4 5
1.
Mounting
C: Mounted with M3 screws
3.
Actuator
0: Pin Plunger
7: Simulated roller leaf lever
2.
Ratings
0: 1 mA at 5 VDC to 0.1 A at 30 VDC
4.
Contact Form
3: SPST-NO
5.
Terminals
H: Solder terminals
Sealed Ultra Subminiature Basic Switch
D2QW
1
Specifications
■ Characteristics
Item
Specification
Operating speed
1 mm to 500 m/s
Operating frequency
30 operations/min
Insulation resistance
100 MΩ min. (at 500 VDC)
Contact resistance
100 mΩ max.
Dielectric strength
600 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and
between each terminal and non-current-carrying metal parts
Vibration resistance (See note 2)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (See note 2)
Destruction: 1,000 m/s2 max.
Malfunction: 300 m/s2 max.
Ambient operating temperature
–40 to 85 °C (with no icing)
Ambient operating humidity
95% max. (for 5 to 35°C)
Degree of protection
IEC IP67 (excluding the terminals on terminal models)
Degree of protection against electric shock
Class I
Proof tracking index (PTI)
175
Life expectancy
Mechanical
(30 operations/min)
500,000 operations min.
Electrical
(20 operations/min)
200,000 operations min. (at 30 VDC 0.1 A)
500,000operations min. (at 14 VDC 10 mA)
Weight
Approx. 0.7 g (for pin plunger models with terminals)
Note: 1. Data shown are of initial value.
2. For pin plunger models, the above values apply for use at the free position, operating position, and total travel position. For models with
levers, the values apply at the total travel position.
■ Ratings
■ Contact Specifications
Rated voltage (V)
30 VDC
14 VDC
Resistive load
Item
0.1 A
10 mA
Note: The resistive load ratings apply under the following test conditions:
Ambient Temperature = 20±2°C,
Ambient Humidity = 65±5%,
Operating frequency = 30 operations/min.
2
Sealed Ultra Subminiature Basic Switch
Specification
Specification
Slide
Material
Gold plated
Minimum applicable load
(reference value)
1 mA at 5 VDC
Note: Minimum applicable loads are indicated by N standard reference values. This value represents the failure rate at a 60%
(λ60) reliability level (JIS C5003).
The equation λ60=0.5 x 10-6 / operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
D2QW
Engineering Data
■ Mounting Structure and Reference Positions for Operating Characteristics
Note: 1. All units are in millimeters unless otherwise indicated.
1.7 dia.
8.3±0.1
(4)
Mounting Hole Dimensions (Reference)
8.2±0.2
5.3±0.2
(depth: 1.5 mm min.)
OT
FP OP
3.2
TTP
0
.1
3 −0
M3 tap
3 +0.1
0 dia. hole
ia.
.1d
±0
5.1
3 +0.1
0
ia.
d
8.3±0.1
4.2
13.3±0.2
■ Terminals
■ Contact Form
Terminal (H)
SPST-NO
COM
3
1.8
1.2
2
4.53
NO
0.4
Dimensions and Operating Characteristics
Note: 1. All units are in millimeters unless otherwise indicated.
Pin Plunger Models
D2QW-C003F
8.3±0.1
1.7 dia.
8.2±0.2
(4)
Characteristic
5.3±0.2
OT
FP
OP
TTP
0
0.1
±
3.2
3 +0.1
0
.
0.1
−
3.2
.
dia
5.1
dia
Models with posts
OF max.
1.5 N {153 gf}
OT ref.
(2.7 mm)
FP max.
OP
TTP max.
9.2 mm
8.4±0.3 mm
5.9 mm
4.2
3
1.8
4.53
Two-1.2
Two-2
0.4
13.3±0.2
Simulated Roller Leaf Lever Models
D2QW-C073H
8.2±0.2
5.3±0.2
3.4
t = 0.2 stainless
A steel lever
OT
(0.45)
FP
OP
TTP
(1.7)
.
dia
.1
0
2±
3.
0
dia
OT ref.
(3.5 mm)
FP max.
OP
TTP max.
14.4 mm
12.0±0.5 mm
8.7 mm
5.1
4.2
3
1.8
Two-1.2
Two-2
Models with posts
1.5 N {153 gf}
3 +0.1
0
.
.1
3 −0
Characteristic
OF max.
4.53
0.4
13.3±0.2
Sealed Ultra Subminiature Basic Switch
D2QW
3
Precautions
Be sure to read the precautions and information common to all Snap Action and Detection Switches, contained in the Technical User’s Guide,
“Snap Action Switches, Technical Information” for correct use.
■ Cautions
■ Correct Use
Degree of Protection
Mounting
IEC Publication 529, degree of protection IP67.
Turn OFF the power supply before mounting or removing the Switch,
wiring, or performing maintenance or inspection. Failure to do so may
result in electric shock or burning.
Do not use this product in water. Although molded lead wire models
satisfy the test conditions for the standard given above, this test is to
check the ingress of water into the switch enclosure after submerging
the Switch in water for a given time. Satisfying this test condition
does not mean that the Switch can be used in water.
Do not operate the Switch when it is exposed to water spray, or when
water drops adhere to the Switch surface, or during sudden temperature changes, otherwise water may intrude into the interior of the
Switch due to a suction effect.
Prevent the Switch from coming into contact with oil and chemicals.
Otherwise, damage to or deterioration of Switch materials may
result.
Do not use the Switch in areas where it is exposed to silicon
adhesives, oil, or grease, otherwise faulty contact may result due to
the generation of silicon oxide.
Soldering
When soldering the lead wire to the terminal, first insert the lead wire
conductor through the terminal hole and then conduct soldering.
Complete soldering within 3 s using a soldering iron with a capacity
of 50 W max. and a tip temperature of 300 °C max.
Also, do not apply an external force to the Switch for 1 minute after
the completion of soldering.
Improper soldering involving an excessively high temperature or
excessive soldering time may deteriorate the characteristics of the
Switch.
When using automatic soldering, solder at at 260 °C max and complete soldering with 5 seconds.
For M3-screw mounting models, use M3 mounting screws with plane
washers or spring washers to securely mount the Switch. Tighten the
screws to a torque of 0.29 N·m {3 kgf·cm}. Exceeding the specified
torque may result in deterioration of the sealing or damage.
For models with posts, secure the posts by thermal caulking or by
pressing into an attached device. When pressed into an attached
device, provide guides on the opposite ends of the posts to ensure
that they do not fall out or rattle.
Mount the Switch onto a flat surface. Mounting on an uneven surface
may cause deformation of the Switch, resulting in faulty operation or
damage.
Operating Body
Use an operating body with low frictional resistance and of a shape
that will not interfere with the sealing rubber, otherwise the plunger
may be damaged or the sealing may deteriorate.
Handling
Do not handle the Switch in a way that may cause damage to the
sealing rubber.
When handling the Switch, ensure that pressure is not applied to the
posts in the directions shown in the following diagram. Also, ensure
that uneven pressure or pressure in a direction other than the operating direction is not applied to the Actuator as shown in the following
diagram. Otherwise, the post, Actuator, or Switch may be damaged,
or the service life may be reduced.
Side-actuated (Cam/Dog) Operation
When using a cam or dog to operate the Switch, factors such as the
operating speed, operating frequency, push-button indentation, and
material and shape of the cam or dog will affect the durability of the
Switch. Confirm performance specifications under actual operation
conditions before using the Switch in applications.
Wiring Molded Lead Wire Models
When wiring molded lead wire models, ensure that there is no weight
on the wire or that there are no sharp bends near the parts where the
wire is drawn out. Otherwise, damage to the Switch or deterioration
in the sealing may result.
Using Micro Loads
Even when using micro load models within the operating range,
inrush currents or surges may decrease the life expectancy of the
Switch. Therefore, insert a contact protection circuit where necessary.
4
Sealed Ultra Subminiature Basic Switch
D2QW
MEMO
Sealed Ultra Subminiature Basic Switch
D2QW
5
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. B117-E-01
6
11/10
Specifications subject to change without notice
Sealed Ultra Subminiature Basic Switch
D2QW