OMRON D6F

MEMS Air Velocity Sensor
D6F-W
MEMS precision technology for
repeatable airflow velocity detection.
• Precision uni-directional air velocity detection with ±5%
full-scale repeatable accuracy.
• Integral passive Dust Segregation System (DSS) prevents
contamination of sensor element.
• Compact size: 39 (L) x 20 (W) x 9 (H) mm
• Output signal amplified & temperature compensated.
• User friendly - no adjustment necessary.
• RoHS Compliant
Ordering Information
Description
Velocity Sensor
Cable Connector Assembly
Case
Applicable Gas
Flow Range
PPS
Air (See note 1.)
0-1 m/sec
D6F-W01A1
0-4 m/sec
D6F-W04A1
0-10 m/sec
D6F-W10A1
---
---
---
Model
D6F-W CABLE
Note: 1. Dry gas must not contain large particles, eg dust, oil, mist.
2. Cable Assembly is sold separately.
Specifications
■ Characteristics
Models
Flow Range (See note 1.)
Applicable Gas (See note 2.)
Electrical Connection
Power Supply
Current Consumption
Operating Output Voltage (VDC)
Output Voltage (Max.)
Output Voltage (Min.)
Accuracy
Repeatability (See note 3.)
Case Material
Degree of Protection
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Temperature Characteristics
Insulation Resistance
Dielectric Strength
Weight
D6F-W01A1
D6F-W04A1
D6F-W10A1
0 to 1 m/s
0 to 4 m/s
0 to 10 m/s
Air
Connector (3 wire)
10.8 to 26.4 VDC
Max. 15 mA (no load, Vcc = 12 to 24VDC, 25°C)
1 to 5 VDC
5.7 VDC (Lead resistance 10kΩ)
0 VDC (Lead resistance 10kΩ)
± 5% F.S. max. of detected characteristics at 25 °C
± 0.4% F.S.
PPS
IP40
-10 to 60°C (with no icing or condensation)
35 to 85% RH (with no icing or condensation)
-40 to 80°C (with no icing or condensation)
35 to 85% RH (with no icing or condensation)
± 5% F.S. max. of detected characteristics at 25 °C (within -10 to 60°C)
20 MΩ (500 VDC between lead terminal and the case)
500 VAC, 50/60 Hz for 1 minute. (Leakage current typ. Max. 1 mA) between lead terminals and case.
6.3 g
Note: 1. Flow range at 0°C, 101.3kPa.
2. Dry gas. (must not contain large particles, dust, oil, mist)
3. Reference (typical)
MEMS Air Velocity Sensor
D6F-W
31
■ Absolute Maximum Rating
Symbol
Rating
Unit
Power supply voltage
Item
Vcc
26.4
VDC
Output voltage
Vout
6.0
VDC
■ Output Voltage Characteristics
D6F-W04A1
D6F-W10A1
6.0
6.0
5.0
5.0
5.0
4.0
3.0
2.0
1.0
0.0
0.00
0.25
0.50
0.75
Flow Velocity (m/s)
Output Voltage (V)
6.0
Output Voltage (V)
Output Voltage (V)
D6F-W01A1
4.0
3.0
2.0
1.0
0.0
0.00
1.00
1.00
2.00
3.00
Flow Velocity (m/s)
4.0
3.0
2.0
1.0
0.0
0
4.00
2
4
6
Flow Velocity (m/s)
8
10
D6F-W01A1
Flow Velocity (m/s)
Output Voltage (VDC)
0.00
0.25
0.50
0.75
1.00
1.00±0.2
1.35±0.2
2.01±0.2
3.27±0.2
5.00±0.2
D6F-W04A1
Flow Velocity (m/s)
Output Voltage (VDC)
0
1
2
3
4
1.00±0.2
1.58±0.2
2.88±0.2
4.11±0.2
5.00±0.2
Note: 1. Air velocity. D6F-W is optimally adjusted for air velocity detection, derived from mass air-flow measurement according
to our in-house test method using a wind tunnel φ 48 mm as
shown in Fig. 1.
2. Measurement condition: Power supply voltage 12±0.1 VDC,
ambient temperature 25±5°C. and dry air.
Fig. 1.
Flow rate measurement positoin
Air Velocity Sensor
48 dia.
20.8
60
D6F-W10A1
Flow Velocity (m/s)
Output Voltage (VDC)
0
2
4
6
8
10
1.00±0.24
1.94±0.24
3.23±0.24
4.25±0.24
4.73±0.24
5.00±0.24
Note: 1. Air velocity. D6F-W is optimally adjusted for air velocity detection, derived from mass air-flow measurement according
to our in-house test method using a wind tunnel φ 155 mm
as shown in Fig. 2.
2. Measurement condition: Power supply voltage 12±0.1 VDC,
ambient temperature 25±5 °C. and dry air.
Fig. 2.
Honeycomb air flow laminater
Air Velocity Sensor
155 dia.
18
Flow rate measurement positoin
10
100
Connections
2. Vout.
The connector linked to this product should use the following JST
Mfg.Co.,Ltd. housing, contacts and electrical wire
3. GND.
1. Vcc.
1) Contact:
Wire:
Connections
Enlarged view
Pin No.
Connector
1: Vcc
2: Vout
3: GND
S3B-ZR-SM2-TF
(Made by JST Mfg. Co.,Ltd.)
32
MEMS Air Velocity Sensor
D6F-W
SZH-002T-P0.5
AWG#28 to #26
OR
2) Contact: SZH-003T-P0.5
Wire: AWG#32 to #28
Housing:
ZHR-3
Dimensions
Note: All units are in millimeters unless otherwise indicated.
D6F-W01A1
D6F-W04A1
D6F-W10A1
9
3.2±0.2
20
1.2
2.6
8
Two, R: 1.6
2.6
1.2
R: 4
Two, M3 screws
8
4.2±0.2
IN
OUT
MADE IN JAPAN
30.5±0.05
5
39 24
5
30.5±0.2
19.5
OUT
2-dia. holes,
Depth: 2.5
4
7
R: 4
3.2±0.2 dia.
D6F-W CABLE
(Sold separately)
5±1
Blue wire
3. GND
Black wire
Brown wire
2. Vout
15±3
30±10
100±10
50±10
1. Vcc
Packaging
TYPE D6F-W
1
3
Item
1
Sock liner
Material
CCNB
2
Tray (25pcs)
Polyethylene
3
Box (100 pcs)
CCNB
55
2
No.
Display seal
25
5
21
5
Application Example
Clogged Filter Detection
The D6F-W air flow sensor detects the decrease in air velocity through the filter as it becomes more contaminated with particles. The moment the
velocity drops below a certain threshold, a warning signal is sent out, indicating the need for filter replacement.
Note: Be sure to read the precautions and information common to all D6F sensors, contained in the Technical User’s Guide, “D6F Technical Information”
for correct use.
MEMS Air Velocity Sensor
D6F-W
33
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
OMRON ELECTRONIC
COMPONENTS LLC
Global - http://www.omron.com
USA - http://www.components.omron.com
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
Cat. No. X305-E-1
10/10
MEMS Air Velocity Sensor
Specifications subject to change without notice
D6F-W