MEDER DIL12-1A72-13EL

DIL Series
MEDER electronic
Sealed DIL Version w/ up to 4.25
kVDC Breakdown Voltage Option
DESCRIPTION
Several pin out options are possible with the 14
pin DIL series. Suitable for telecommunication
applications where breakdown voltages up to 4.25
kVDC is required.
FEATURES
CHARACTERISTICS
• 2 Form C available
• High resistance available
• 2 Form A switches available
• Magnetic shield available
• 4.25 kVDC breakdown voltage available
• High power switching available
• Compatible with DIL socket
• Coil resistance up to 11 kΩ
• Diode option
DIMENSIONS
All dimensions in mm [inches]
ORDER INFORMATION
Part Number Example
Series
Nominal
Voltage
Contact
Form
Switch
Model
Pin Out
Option
() Version with
magnetic Shield
Version
DIL
XX -
XX
XX -
XX
X
XX
1A
66, 72, 75
13*,15
2A
66, 72, 75
21
05, 12
1C
90
51*
05, 12, 24
2C
90
62, 63
HR, L
05, 12, 24
Options
* When HR is selected, 24 V coil is not available.
L = No Option.
L(M),D(Q),E(R)t,
F(S)tt
HR, L
L
t
Not available with Pin out 62, 63.
www.meder.com
134
L
DIL12 - 1A72 - 10LHR
12 is the nominal voltage
1A is the contact form
72 is the switch model
13 is the pin out
L is the option
HR is the high resistance version
DIL Series
MEDER electronic
Sealed DIL Version w/ up to 4.25
kVDC Breakdown Voltage Option
PIN OUT
OPTIONS
( ) Versions with magnetic shield
Please note: Any option can affect the coil resistance, the breakdown voltage or other electrical data. Please contact us.
Special performance:
The following special options are available on request:
• Other pinning layouts
• Other coil resistance values
• Other switches available
www.meder.com
135
DIL Series
MEDER electronic
Sealed DIL Version w/ up to 4.25
kVDC Breakdown Voltage Option
RELAY DATA
All Data at 20° C
Switch Model →
Contact Form →
Contact Ratings
Conditions
Switching Power
Any DC combination of V & A not
to exceed their individual max.‘s.
Switching Voltage
Switch 66
Form A
Switch 72
Form A
Min. Typ. Max. Min. Typ. Max. Units
10
15
W
DC or peak AC
200
200
V
Switching Current
DC or peak AC
0.5
1.0
A
Carry Current
DC or peak AC
1.25
1.25
A
Static Contact Resistance
w/ 0.5 V & 50mA
150
150
mΩ
Dynamic Contact
Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
200
200
mΩ
Insulation Resistance
(100 Volts applied)
Across Contact
Contact to coil
1010
1012
1012
1012
Ω
Breakdown Voltage
Across Contact
Contact to coil
225
1.5*
250
1.5*
VDC
kVDC
Operate Time incl. Bounce
With nominal voltage
0.5
0.7
ms
Release Time
Measured w/ no coil suppression
0.1
0.1
ms
Capacitance
Across Contact
Contact to coil
0.2
4.0
0.2
4.0
pF
1000
1000
106
Cycles
Life Expectancies
Switching 5V - 10 mA
DC <10 pF stray cap.
For other load requirements, see the life test section on P. 112.
Environmental Data
Shock Resistance
1/2 sine wave duration for 11 ms
50
50
Vibration Resistance
From 10 - 2000 Hz
20
20
Ambient Temperature
max. 10°C/ minute allowable
-20
70
-20
Storage Temperature
max. 10°C/ minute allowable
-25
85
-35
Soldering Temperature
5 sec. dwell
* 4.25 kVDC / 3.0 kVRMS for Pin-outs 13 and 15.
www.meder.com
136
260
g
g
70
o
C
95
o
C
260
o
C
MEDER electronic
DIL Series
Sealed DIL Version w/ up to 4.25
kVDC Breakdown Voltage Option
RELAY DATA
All Data at 20° C
Switch Model →
Contact Form →
Contact Ratings
Conditions
Switching Power
Any DC combination of V & A not
to exceed their individual max.‘s.
Switching Voltage
Switch 75
Form A
Switch 90
Form C
Min. Typ. Max. Min. Typ. Max. Units
10
10
W
DC or peak AC
500
175
V
Switching Current
DC or peak AC
0.5
0.5
A
Carry Current
DC or peak AC
1.0
1.0
A
Static Contact Resistance
w/ 0.5 V & 50mA
200
150
mΩ
Dynamic Contact
Resistance
Measured w/ 0.5 V & 50mA ,
1.5 ms after closure
200
250
mΩ
Insulation Resistance
(100 Volts applied)
Across Contact
Contact to coil
1010
1012
109
1012
Ω
Breakdown Voltage
Across Contact
Contact to coil
1500
1.5*s
200
1.5
VDC
kVDC
Operate Time incl. Bounce
With nominal voltage
0.5
0.7
ms
Release Time
Measured w/ no coil suppression
0.1
1.5
ms
Capacitance
Across Contact
Contact to coil
0.4
4.0
1.0
4.0
pF
DC <10 pF stray cap.
500
100
106
Cycles
Life Expectancies
Switching 5V - 10 mA
For other load requirements, see the life test section on P. 112.
Environmental Data
Shock Resistance
1/2 sine wave duration for 11 ms
50
50
Vibration Resistance
From 10 - 2000 Hz
20
20
Ambient Temperature
max. 10°C/ minute allowable
-20
70
-20
Storage Temperature
max. 10°C/ minute allowable
-25
85
-25
Soldering Temperature
5 sec. dwell
260
g
g
70
o
C
85
o
C
260
o
C
* 4.25 kVDC / 3.0 kVRMS for Pin-outs 13 and 15.
www.meder.com
137
DIL Series
MEDER electronic
Sealed DIL Version w/ up to 4.25
kVDC Breakdown Voltage Option
COIL DATA
Contact
Form
Switch
Model
All Data
at 20 °C
1A
2A
66
72
75
66
72
75
1C
Coil
Voltage
Coil
Resistance
Pull-in
Voltage
Drop-Out
Voltage
Nominal
Coil Power
VDC
Ω
VDC
VDC
mW
Nom.
Max.
Min.
Typ.
Max.
Max.
Min.
Typ.
5
7.5
405
450
495
3.5
0.75
55
12
16
1620
1800
1980
8.4
1.8
80
24
30
4050
4500
4950
16.8
3.6
130
5
7.5
180
200
220
3.5
0.75
125
12
16
621
680
748
8.4
1.8
210
24
30
1800
2000
2200
16.8
3.6
290
5
7.5
180
200
220
3.5
0.75
125
12
16
900
1000
1100
8.4
1.8
145
24
30
2700
3000
3300
16.8
3.6
190
5
7.5
145
150
165
3.5
0.75
165
12
16
612
680
748
8.4
1.8
210
24
30
1800
2000
2200
16.8
3.6
290
90
2C
The pull-in, drop-out voltages and coil resisitance will change at the rate of 0,4 % per °C.
www.meder.com
138