OMRON E39-L143

Manual Fiber Amplifier
E3X-NA
CSM_E3X-NA_DS_E_2_2
Simple and Easy-to-Use Amplifiers
with a Sensitivity Adjuster
Provided as a Standard Feature
■ Intuitive LED bar display shows light levels at a glance.
■ Utilizes OMRON’s innovative wire-saving connector.
■ Reduced wiring and space requirements for power
lines.
■ Optical communications prevents mutual interference
for up to 5 amplifiers
■ High-speed detection, mark-detecting, and waterresistant models also available.
Be sure to read Safety Precautions on
page 10.
Ordering Information
Amplifier Units
Amplifier Units with Cables (2m)
Item
Appearance
Model
Control output
Standard models
With self-diagnosis function
High-speed detection models
ON/OFF output
Mark-detecting models
Water-resistant models
NPN output
PNP output
E3X-NA11 2M
E3X-NA41 2M
E3X-NA21 2M
E3X-NA51 2M
E3X-NA11F 2M
E3X-NA41F 2M
E3X-NAG11 2M
E3X-NAG41 2M
E3X-NA11V 2M
E3X-NA41V 2M
Amplifier Units with Connectors
Item
Applicable Connector
(order separately)
Appearance
Master
E3X-CN11
Slave
E3X-CN12
Control output
Standard models
Model
NPN output
PNP output
E3X-NA6
E3X-NA8
E3X-NA14V
E3X-NA44V
ON/OFF output
Water-resistant
models
(M8 connectors)
XS3F-M421-40@-A
XS3F-M422-40@-A
Amplifier Unit Connectors (Order Separately)
Item
Note: Stickers for Connectors are included as accessories.
Appearance
Cable length
Master Connector
No. of
conductors
Model
3
E3X-CN11
1
E3X-CN12
2m
Slave Connector
1
E3X-NA
Combining Amplifier Units and Connectors
Refer to the following tables when placing an order.
Basically, Amplifier Units and Connectors are sold
separately.
Type
Standard
models
Amplifier Units
NPN
E3X-NA6
PNP
+
E3X-NA8
Applicable Connectors (Order Separately)
Master Connector
Slave Connector
E3X-CN11 (3-wire)
E3X-CN12 (1-wire)
When Using 5 Amplifier Units
5 Amplifier Units
+
1 Master Connector + 4 Slave Connectors
Sensor I/O Connectors (Order Separately)
Size
Cable specifications
Appearance
Cable type
2m
Four5m
conductor
2m
cable
5m
Straight connector
M8
Standard cable
L-shaped connector
Model
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Note: Refer to Introduction to Sensor I/O Connectors for details.
Accessories (Order Separately)
Mounting Brackets
Appearance
Applicable models
End Plate
Model
E3X-NA@
E3X-NA@F
E3X-NAG@
E39-L143
E3X-NA@V
E39-L148
Quantity
Appearance
Model
PFP-M
Quantity
1
1
2
E3X-NA
Ratings and Specifications
Amplifier Units
Type
Model
Item
Standard models
High-speed
detection models
Mark-detecting models
Water-resistant models
E3X-NA@
E3X-NA@F
E3X-NAG@
E3X-NA@V
NPN
output
PNP
output
Light source
(wavelength)
Red LED (680 nm)
Power supply
voltage
12 to 24 VDC ”10%, ripple (p-p): 10% max.
Current
consumption
35 mA max.
Control output
Load current: 50 mA max.; residual voltage: 1 V max.; NPN/PNP (depends on model) open collector; Light-ON/Dark-ON mode selector
Self-diagnosis
output
None
Response time
Operate or reset: 200 Ps max. *1
Sensitivity
adjustment
8-turn sensitivity adjuster (with indicator)
Protection circuits
Reverse polarity, output short-circuit, mutual interference prevention (optically synchronized) *2
Timer function
OFF-delay timer: 40 ms (fixed)
Ambient illumination
(Receiver side)
Incandescent lamp: 10,000 lux max.
Sunlight:
20,000 lux max.
Ambient
temperature range
Operating:Groups of 1 to 3 Amplifiers: 25“C to 55“C
Groups of 4 to11 Amplifiers: 25“C to 50“C
Groups of 12 to16 Amplifiers: 25“C to 45“C
Storage: 30“C to 70“C (with no icing or condensation)
Ambient humidity
range
Operating and storage: 35% to 85% (with no condensation)
Green LED (520 nm)
35 mA max.
(for 24-VDC power supply)
Yes
Red LED (680 nm)
35 mA max.
None
Operate: 20 Ps max.
Reset: 30 Ps max.
Operate or reset: 200 Ps max. *1
Insulation resistance 20 M: min. (at 500 VDC)
Dielectric strength
1,000 VAC at 50/60 Hz for 1 minute *3
Vibration resistance
Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions
Shock resistance
Destruction: 500 m/s2, for 3 times each in X, Y and Z directions
Degree of protection
IEC 60529 IP50 (with Protective Cover attached)
Connection method
Pre-wired (standard cable length: 2 m) or connector
Weight
(packed state)
Pre-wired models: approx. 100 g, Connector models: approx. 55 g (See note 4.) *4
Material
Case
Polybutylene terephthalate (PBT)
Cover
Polycarbonate
Accessories
*1.
*2.
*3.
*4.
IEC 60529 IP66 (with Protective Cover attached)
Polyethersulfone (PES)
Instruction manual
When there are 8 or more Units mounted side-by-side, the response time will be 350 Ps max.
High-speed detection models do not have the mutual interference prevention function.
The dielectric strength for water-resistant models with M8 connectors is 500 VAC.
Add 10 g to the weight for water-resistant models.
Amplifier Unit Connectors
Item
Model
E3X-CN11
E3X-CN12
Rated current
2.5 A
Rated voltage
50 V
Contact resistance
20 m: max. (20 mVDC max., 100 mA max.)
(The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.)
Number of insertions
Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector)
Material
Housing
Polybutylene terephthalate (PBT)
Contact
Phosphor bronze/gold-plated nickel
Weight
(packed state)
Approx. 55 g
Approx. 25 g
3
E3X-NA
Sensing Distance
Through-beam Models
(Unit: mm)
Model
Type
Flexible
(new standard)
Standard
models
Standard
Break resistant
Fluorine coating
Long distance,
high power
Special-beam
models
Ultracompact,
ultrafine sleeve
Fine beam (narrow vision field)
Area sensing
Heat resistant
Environmentresistive
models
Chemical
resistant
Vacuum
resistant
E32-T11R/E32-T12R/E32-T15XR/E32-TC200BR(B4R)
E32-T14LR/E32-T15YR/E32-T15ZR
E32-T21R/E32-T22R/E32-T222R/E32-T25XR/
E32-TC200FR(F4R)
E32-T24R/E32-T25YR/E32-T25ZR
E32-TC200/E32-T12/E32-T15X/E32-TC200B(B4)
E32-T14L/E32-T15Y/E32-T15Z
E32-TC200A
E32-TC200E/E32-T22/E32-T222/E32-T25X/E32-TC200F(F4)
E32-T24/E32-T25Y/E32-T25Z
E32-T11/E32-T12B/E32-T15XB
E32-T21/E32-T221B/E32-T22B
E32-T25XB
E32-T11U
E32-T17L
E32-TC200 + E39-F1
E32-T11R + E39-F1
E32-T11 + E39-F1
E32-T14
E32-T11L/E32-T12L
E32-T11L + E39-F2
E32-T11R + E39-F2
E32-T11 + E39-F2
E32-T21L/E32-T22L
E32-T223R
E32-T33-S5
E32-T333-S5
E32-T334-S5
E32-T22S
E32-T24S
E32-T16PR
E32-T16P
E32-T16JR
E32-T16J
E32-T16WR
E32-T16W
E32-T16
E32-M21
E32-T51
E32-T54
E32-T81R-S
E32-T61-S + E39-F2
E32-T61-S + E39-F1
E32-T84S-S
E32-T61-S
E32-T11F
E32-T12F
E32-T14F
E32-T51F
E32-T81F-S
E32-T51V
E32-T51V + E39-F1V
E32-T54V
E32-T54V + E39-F1V
E32-T84SV
E3X-NA@
General-purpose
models
280
110
E3X-NA@F
High-speed
models
80
33
60
18
30
400
240
360
100
90
360
100
75
360
14000
3000
2100
2000
1800
700
500
220
360
200
60
20
5
2.5
1000
700
450
600
390
520
690
920
1500
300
400
130
180
390
3000
700
300
1050
1600
200
700
350
100
600
65
390
250
9
120
70
100
30
27
100
30
20
100
4200
900
630
600
540
210
150
65
100
60
18
6
1.5
0.8
300
210
130
180
110
150
200
270
450
90
120
35
50
130
900
210
90
380
480
60
200
100
-----------
4
E3X-NA
Reflective Models
(Unit: mm)
Model
Type
E32-D11R/E32-D12R/E32-D15XR/E32-DC200BR(B4R)
E32-D14LR
E32-D15YR/E32-D15ZR
Flexible
(new standard) E32-D211R/E32-D21R/E32-D22R/E32-D25XR/
E32-DC200FR(F4R)
E32-D24R
E32-D25YR/E32-D25ZR
E32-DC200/E32-D15X/E32-DC200B(B4)
E32-D12
E32-D14L
Standard
models
E32-D15Y/E32-D15Z
Standard
E32-D211/E32-DC200E/E32-D22/E32-D25X/
E32-DC200F(F4)
E32-D24
E32-D25Y/E32-D25Z
E32-D11/E32-D15XB
E32-D21B/E32-D221B
Break resistant
E32-D21/E32-D22B
E32-D25XB
Fluorine coating E32-D11U
E32-D16
Long distance,
E32-D11L
high power
E32-D21L/E32-D22L
Ultracompact, E32-D33
ultrafine sleeve E32-D331
E32-CC200R
E32-CC200
E32-D32L
E32-C31/E32-D32
E32-C42 + E39-F3A
Coaxial,
E32-D32 + E39-F3A
small spot
E32-C41 + E39-F3A-5
Special-beam
E32-C31 + E39-F3A-5
models
E32-C41 + E39-F3B
E32-C31 + E39-F3B
E32-C31 + E39-F3C
Area sensing E32-D36P1
E32-R21 + E39-R3 (provided)
Retro-reflective
E32-R16 + E39-R1 (provided)
E32-L25/E32-L25A
E32-L24S
E32-L24L
Convergentreflective
E32-L25L
E32-L86
E32-L16
E32-D51
Heat resistant E32-D81R/E32-D61
EnvironmentE32-D73
resistive models
E32-D12F
Chemical
resistant
E32-D14F
E3X-NA@
General-purpose
models
90
16
20
E3X-NA@F
High-speed
models
30
5
5
15
5
7
4
150
120
40
50
2.3
1.2
50
40
13
15
36
12
15
5
10
3.3
90
30
35
10
15
5
25
8
90
30
40 to 400
55 to 70
200
65
50
17
10
3.3
1.5
0.5
75
25
150
50
80
25
40
13
Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm.
Spot diameter of 0.5 to 1mm at 6 to 15 mm.
Spot diameter of 0.1 mm at 7 mm
Spot diameter of 0.5 mm at 7 mm.
Spot diameter of 0.2 mm at 17 mm.
Spot diameter of 0.5 mm at 17 mm.
Spot diameter of 4 mm max. at 0 to 20 mm.
75
25
10 to 250
150 to 1500
150 to 1000
3.3
0 to 4
2 to 6 (center 4)
5.4 to 9 (center 7.2)
4 to 10
0 to 15
0 to 13
120
40
45
15
30
10
50
16
20
6.5
5
E3X-NA
Application-specific Models
(Unit: mm)
Model
Type
Label detection
Applicationspecific Models
E32-G14
E32-T14
E32-D36T
E32-D82F1(F2)
Green Light Source Models
(Unit: mm)
Model
Type
Through-beam
models
Reflective
Application
specific
E3X-NA@F
High-speed
models
10
1800
540
Applicable tube: Transparent tube with a
diameter in the range 8 to 10 mm and a
recommended wall thickness of 1 mm
Applicable tube: Transparent tube
(no diameter restrictions )
Liquid-contact model
E32-L25T
Liquid-level
detection
E3X-NA@
General-purpose
models
E32-T11R/E32-T12R/E32-T15XR/E32-TC200BR(B4R)
E32-T14LR/E32-T15YR/E32-T15ZR
Standard
E32-TC200/E32-T12/E32-T15X/E32-TC200B(B4)
E32-T14L/E32-T15Y/E32-T15Z
Special beam E32-T11L/E32-T12L
E32-D11R/E32-D12R/E32-D15XR/E32-DC200BR(B4R)
E32-D14LR
E32-D15YR/E32-D15ZR
Standard
E32-DC200/E32-D15X/E32-DC200B(B4)
E32-D14L
E32-D15Y/E32-D15Z
E32-D11L
E32-CC200R
Special beam E32-CC200
E32-D32L
E32-C31/E32-D32
E32-T14
Label detection
E32-G14
E3X-NAG@
Mark-detecting Models
50
20
75
45
130
15
3.5
3.3
25
10
8
35
12
25
12
6
330
10
Refer to E32 Series for details on Fiber Units.
6
E3X-NA
Engineering Data (Typical)
Number of Turns of Sensitivity Adjuster vs. Sensing Distance
E32-D11L
1.2
Distance (mm)
Distance (m)
E32-T11L
1.0
0.8
E3X-NA@(V)
400
300
E3X-NA@(V)
200
0.6
0.4
100
0.2
E3X-NA@F
2
0
4
6
E3X-NA@F
8
10
0
2
4
6
8
10
Number of turns
Number of turns
Sensing Distance vs. Differential Travel
E32-D11L
100
Differential travel (mm)
Differential travel (mm)
E32-T11L
80
60
E3X-NA@(V)
40
15
10
E3X-NA@(V)
5
20
0
20
100
200
300
400
500
600 700
Distance (mm)
0
50
100
150
200
Distance (mm)
7
E3X-NA
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Timing charts
Operation
selector
Output circuit
Incident light
Light-ON
E3X-NA11
E3X-NA6
E3X-NAG11
E3X-NA11F
E3X-NA11V
E3X-NA14V
No incident light
Operation
ON
indicator
(orange)
OFF
Output
transistor
T
LIGHT ON
(L-ON)
ON
Operation indicator
(orange)
Photoelectric
Sensor
main
circuit
OFF
Operate
Load
(relay)
Reset
(Between brown and black leads)
Brown
1
Load
Black
4
Control output
12 to
24 VDC
Blue
3
Incident light
Dark-ON
No incident light
Operation
ON
indicator
(orange)
OFF
Output
transistor
T
DARK ON
(D-ON)
ON
OFF
M8 Connector Pin Arrangement
2 4
1
3
Note: Pin 2 is not used.
Operate
Load
(relay)
Reset
(Between brown and black leads)
Incident light
Light-ON
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
transistor
OFF
T
LIGHT ON
(L-ON)
Photoelectric
Sensor
main
circuit
E3X-NA21
Incident light
Dark-ON
Output
transistor
Brown
12 to
24 VDC
Load
(relay)
Operate
Load
(relay)
Reset
(Between brown and black leads)
No incident light
Operation
ON
indicator
(orange)
OFF
Operation indicator
(orange)
Black Control
output
Orange
Load
(relay)
Self-diagnosis output
T
ON
DARK ON
(D-ON)
Incident level
indicators
(4 green, 1 red)
Blue
0V
OFF
Operate
Load
(relay)
Reset
(Between brown and black leads)
8
E3X-NA
PNP Output
Operation
mode
Model
Operation
selector
Timing charts
Output circuit
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
ON
Output
Light-ON
LIGHT ON
(L-ON)
OFF
transistor
Load
Operate
(relay)
Reset
E3X-NA41
E3X-NA8
E3X-NAG41
E3X-NA41F
E3X-NA41V
E3X-NA44V
Brown
Operation
indicator
(orange)
T
1
Photoelectric
Sensor
main
circuit
Black
Control
output
12 to
24 VDC
4
Load
Blue
(Between blue and black leads)
3
Incident light
No incident light
Operation
ON
indicator
(orange)
OFF
Dark-ON
Output
transistor
T
M8 Connector Pin Arrangement
DARK ON
(D-ON)
ON
2 4
1
3
Note: Pin 2 is not used.
OFF
Operate
Load
(relay)
Reset
(Between blue and black leads)
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
Light-ON
Output
transistor
T
LIGHT ON
(L-ON)
ON
OFF
Operate
Load
(relay)
Reset
(Between blue and black leads)
E3X-NA51
Dark-ON
Output
transistor
Orange
Photoelectric
Sensor
main
circuit
Incident light
No incident light
Operation
ON
indicator
OFF
(orange)
Brown
Operation indicator
(orange)
Control
Black output
DARK ON
(D-ON)
Self-diagnosis output
Load
(relay)
Load
(relay)
T
ON
12 to
24 VDC
Incident level
indicators
(4 green, 1 red)
Blue
0V
OFF
Operate
Load
(relay)
Reset
(Between blue and black leads)
Plug (Sensor I/O Connector)
Terminal number
4
3
2
1
Wire color
Classification
Wire color
Connection pin
Brown
1
White
2
Blue
3
Black
4
Brown
White
Blue
Black
1
2
3
4
DC
XS3F-M421-402-A
XS3F-M421-405-A
XS3F-M422-402-A
XS3F-M422-405-A
Application
Power supply
(+V)
--Power supply
(0 V)
Output
Note: Pin 2 is not used.
Nomenclature
Amplifier Units
Sensitivity indicator
8-turn sensitivity adjuster
Lock lever
Incident level indicators
Operation Indicator
Operation Selector
Use to switch between
Light-ON and Dark-ON
Timer switch
ON: Timer function is ON.
OFF: Timer function is OFF.
9
E3X-NA
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
Precautions for Correct Use
Do not use the product in atmospheres or environments that exceed
product ratings.
Fiber Connection and Disconnection
The E3X Amplifier Unit has a lock lever. Connect or disconnect the
fibers to or from the E3X Amplifier Unit using the following
procedures:
1. Connection
Open the Protective Cover, insert the fibers according to the fiber
insertion marks on the side of the Amplifier Unit, and lower the lock
lever.
Amplifier Units
Insertion position
Lock button
● Designing
Communications Hole
The hole on the side of the Amplifier Unit is a communications hole for
preventing mutual interference when Amplifier Units are mounted
side-by-side. The E3X-MC11 Mobile Console (order separately)
cannot be used.
If an excessive amount of light is received via the Sensor, the mutual
interference prevention function may not work. In this case, make the
appropriate adjustments using the sensitivity adjuster.
The mutual interference prevention function will not operate when the
E3X-NA is used side-by-side with E3X-DA-N models.
Fiber
Fiber insertion mark
10.7 mm
2. Disconnection
Remove the Protective Cover and raise the lock lever to pull out the
fiber.
● Mounting
DIN Track Mounting/Removal
Protective cover
Mounting Amplifier Units
1. Mount the Amplifier Units one at a time onto the DIN track.
Locked
Unlocked
Note:To maintain the fiber properties, confirm that the lock is released
before removing the fiber.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
3. Precautions for Fiber Connection/Disconnection
Be sure to lock or unlock the lock lever within an ambient temperature
range between 10“C and 40“C.
● Operating Environment
Ambient Conditions
Clip
Click into
place
Removing Amplifier Units
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
If dust or dirt adhere to the hole for optical communications, it may
prevent normal communications. Be sure to remove any dust or dirt
before using the Units.
● Other
Protective Cover
Be sure to mount the Protective Cover before use.
Note: 1. The specifications for ambient temperature will vary according to the
number of Amplifier Units used together. For details, refer to Ratings
and Specifications.
2. Always turn OFF the power supply before mounting or removing
Amplifier Units.
10
E3X-NA
Amplifier Units with Connectors
● Mounting
Mounting Connectors
Mounting End Plate (PFP-M)
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
Depending on how it is mounted, an Amplifier Unit may move during
operation. In this case, use an End Plate.
Before mounting an End Plate, remove the clip from the master
Amplifier Unit using a nipper or similar tool.
Insert
2. Join Amplifier Units together as required after all the Master and
Slave Connectors have been inserted.
3. Attach the seals (provided as accessories) to the sides of Master
and Slave Connectors that are not connected to other Connectors.
Clip
The clip can also be removed using the following mechanism, which
is incorporated in the construction of the section underneath the clip.
1. Insert the clip to be removed into the slit underneath the clip on
another Amplifier Unit.
Sticker
Sticker
Note: Attach the stickers to the sides with grooves.
Removing Connectors
1. Slide the slave Amplifier Unit for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Press down
Lever
2. Remove the clip by rotating the Amplifier Unit.
Rotate
Remove
Pull Strengths for Connectors (Including Cables)
E3X-CN11: 30 N max.
E3X-CN12: 12 N max.
11
E3X-NA
Dimensions
(Unit: mm)
Amplifier Units
Amplifier Units with Cables
E3X-NA11
E3X-NA11F
E3X-NA41
E3X-NA41F
E3X-NAG11
E3X-NAG41
E3X-NA21
E3X-NA51
With Mounting Bracket Attached
Incident level indicators
A (See note 1.)
Operation indicator
4-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.2
mm2; Insulator diameter: 1.1 mm),
Standard length: 2 m.
* The EX3-NA21 and E3X-NA51 use
4-conductor cable.
13.05
15.75
9.2
3
Two, 2.4 dia.
64.3
10
38.6
5.3
Mounting Holes
Two, M3
31.5
8
9.9
10.7
16
10.75
4.1
Hole for optical communications (See note 2.)
2.4
16
22.4
13
4
34.8
Two, 3.2-dia. holes
22.4
Mounting bracket (E39-L143) (Order separately)
Stainless steel (SUS304)
16
4.4
3.4
4.4
Amplifier Units with Cables, Water-resistant Models
E3X-NA11V
E3X-NA41V
3.4
With Mounting Bracket Attached
28.65
25.95
9.2
(See note 2.)
Operation indicator
Incident level indicators
81.5
6.9
40
12
Note: 1. The mounting bracket can also be
used on side A.
2. The hole for optical
communications is for preventing
mutual interference. There is no
hole for E3X-NA@F models.
A (See note 1.)
Two, 2.4 dia.
2.8
33
8
9.9
11.2
10.7
16
37
67.2
23.9
14.4
3.9 3.4 4.3
11.5
Mounting Holes
Two, M3
23.9
16
3.4
Hole for
optical
communications
6.6
Mounting bracket (E39-L148) (Order separately)
5.4 Stainless steel (SUS304)
16
5.4
3.4
Note: 1. The mounting bracket can also be used on
side A.
2. 4-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.45
mm2, Insulator diameter: 1.1 mm),
Standard length: 2 m.
12
E3X-NA
Amplifier Units with Connectors
E3X-NA6
E3X-NA8
Incident level indicators
Operation indicator
13.05
15.75
10
9.2
3
Two, 2.4 dia.
64.3
31.5
8
14
9.9
10.7
5.5
3.4
1.8
38.6
13
5.1 3.9
1.7
36.7
Hole for optical communications
(for preventing mutual interference)
1.8
4.2
6.2
1.7
Dimensions with Master Connector Connected
Dimensions with Slave Connector Connected
71
67.5
64.3
71
67.5
64.3
E3X-CN12:
2.6 dia.
E3X-CN11:
4.0 dia.
31.5
31.5
1.5
1.8 5.1 3.9
17.45
12.95 11.55
1.5
12.95
4
10
1.8 5.1 3.9
3
4.8
4
10
13
E3X-NA
With Mounting Bracket Attached
Amplifier Units with Connectors, Water-resistant
Models
* The mounting bracket can also be
E3X-NA14V
used on this side.
E3X-NA44V
28.65
25.95
9.2
Operation indicator
Incident level indicators
81.5
6.9
40
12
*
Two, 2.4 dia.
2.8 M8
33
8
9.9
11.2
10.7
11.5
Mounting Holes
Two, M3
23.9
Hole for
optical
communications
16
37
67.2
23.9
14.4
3.9 3.4 4.3
16
3.4
11
5.4
Mounting bracket (E39-L148) (Order separately)
Stainless steel (SUS304)
16
5.4
3.4
Amplifier Unit Connectors
Sensor I/O Connectors
Accessories (Order Separately)
Mounting Brackets
End Plates
Refer to E32 Series for details on Fiber Units.
14