Simple Fiber Amplifier E3X-SD The Standard for Fiber Amplifiers with Simple Operation and High Performance ■ Operation so simple that essentially anyone can use the amplifier right way. ■ Immediately determine operation and amount of light with a simple, bright display. ■ General-purpose capabilities to simply handle a broad range of applications. Ordering Information Amplifier Units Amplifier Unit Connectors (Order Separately) Digital Display and Direct Key Setting Item Appearance Standard models Note: Stickers for Connectors are included as accessories. Model Connection Ratings and method Specifications Pre-wired NPN output Item PNP output Appearance Cable length Master Connector Slave Connector Wire-saving connector Model 3 E3X-CN11 1 E3X-CN12 2m E3X-SD11 E3X-SD41 --- No. of conductors E3X-SD6 E3X-SD8 Amplifier Units Combining Amplifier Units and Connectors (Basically, Amplifier Units and Connectors are sold separately) Refer to the following tables when placing an order. Applicable Connectors (Order Separately) Type NPN PNP Standard models E3X-SD6 E3X-SD8 + Master Connector Slave Connector E3X-CN11 (3-wire) E3X-CN12 (1-wire) When Using 5 Amplifier Units 5 Amplifier Units + 1 Master Connector + 4 Slave Connectors Sensor I/O Connectors (Order Separately) Size Cable specifications M8 Appearance Cable type Straight connector 2m L-shaped connector 2m 5m Standard cable Model XS3F-M421-402-A Fourconductor cable 5m XS3F-M421-405-A XS3F-M422-402-A XS3F-M422-405-A Accessories (Order Separately) Mounting Brackets Appearance End Plate Applicable models E3X-SD@ Model Quantity E39-L143 1 Appearance Model Quantity PFP-M 1 1 E3X-SD Ratings and Specifications Amplifier Units Digital display and direct key setting Type Item Standard models Model E3X-SD@ Light source (wavelength) Red LED (620 nm) Power supply voltage 12 to 24 VDC ±10%, ripple (p-p): 10% max. Current consumption 960 mW max. (Power supply: 24 V, Current consumption: 40 mA max.) Control output Open-collector output (NPN or PNP) Load power supply: 26.4 V max., Load current: 50 mA max. (Residual voltage: 1.5 V max.) Light-ON/Dark-ON mode selector Response time Operate or reset: 200 μs max. Sensitivity adjustment UP/DOWN direct key setting, teaching Protection circuits Power supply reverse polarity protection, output short-circuit protection, output reverse polarity protection Timer function ON/OFF-delay timer: 10 ms (each fixed) Mutual interference prevention Up to 5 Amplifiers (optically synchronized) Ambient illumination Receiver side Incandescent lamp: 10,000 lux max. Sunlight: 20,000 lux max. Ambient temperature range Operating: Groups of 1 to 3 Amplifiers: −25°C to 55°C Groups of 4 to 11 Amplifiers: −25°C to 50°C Groups of 12 to 16 Amplifiers: −25°C to 45°C Storage: −30°C to 70°C (with no icing or condensation) Ambient humidity range Operating and storage: 35% to 85% (with no condensation) Insulation resistance 20 MΩ. min. (at 500 VDC) Dielectric strength 1,000 VAC at 50/60 Hz for 1 minute (*) Vibration resistance Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hrs each in X, Y and Z directions Shock resistance Destruction: 500 m/s2, for 3 times each in X, Y and Z directions Degree of protection IEC 60529 IP50 (with Protective Cover attached) Connection method Pre-wired (standard cable length: 2 m), or connector Weight (packed state) Material Pre-wired model: Approx. 100 g, Model with connector: Approx. 55 g Case Polybutylene terephthalate (PBT) Cover Polycarbonate Accessories Instruction manual * Models with connectors have a dielectric strength of 500 VAC. Amplifier Unit Connectors Item Model 2.5 A Rated voltage 50 V Contact resistance 20 mΩ max. (20 mVDC max., 100 mA max.) (The above figure is for connection to the Amplifier Unit and the adjacent Connector. It does not include the conductor resistance of the cable.) Number of insertions Material Destruction: 50 times (for connection to the Amplifier Unit and the adjacent Connector) Housing Polybutylene terephthalate (PBT) Contact Phosphor bronze/gold-plated nickel Weight (packed state) 2 E3X-CN11 Rated current Approx. 55 g E3X-SD Fiber Unit Overview No snagging, no breaking: Right-angle (L-shaped) Models Feature 90 mm 1 L-shaped Attachment Feature 2 New Head Shape Reflective model, M6 screw E32-D11N 10 mm* 280 mm Through-beam model, M4 screw E32-T11N No snagging during maintenance. Fiber flexibility prevents breaking. 8 mm* Convenient design accommodates two wrench sizes. Allows quick tightening. *For M6 models. Flat and flexible fiber models are easy to mount and will not break. Feature No Breaking Reflective Fiber Units Flat View E32-D15ZR Conventional fiber Flexible fiber Cores Cladding 20 mm A large number of ultrafine cores are all surrounded by cladding. As a result, the fiber is flexible and can be bent without significantly reducing the light intensity. This helps solve problems, such as fiber being broken by getting caught on other objects. Size: 15 × 10 × 3 mm Through-beam Fiber Units Top View E32-T15XR Side View E32-T15YR Flat View E32-T15ZR 110 mm 280 mm 110 mm Size: 15 × 8 × 3 mm 3 E3X-SD Sensing Distance Through-beam Models (Unit: mm) Model Type E3X-SD@ Standard models E32-T11R/E32-T12R/E32-T15XR/E32-TC200BR (B4R) E32-T14LR/E32-T15YR/E32-T15ZR Flexible E32-T21R/E32-T22R/E32-T222R/E32-T25XR/ (new standard) E32-TC200FR (F4R) E32-T24R/E32-T25YR/E32-T25ZR E32-TC200/E32-T12/E32-T15X/E32-TC200B (B4) E32-T14L/E32-T15Y/E32-T15Z Standard models Standard E32-TC200A E32-TC200E/E32-T22/E32-T222/E32-T25X/E32-TC200F (F4) E32-T24/E32-T25Y/E32-T25Z E32-T11/E32-T12B/E32-T15XB Break resistant E32-T21/E32-T221B/E32-T22B E32-T25XB Fluorine coating E32-T11U E32-T17L E32-TC200 + E39-F1 E32-T11R + E39-F1 E32-T11 + E39-F1 E32-T14 Long distance, high power E32-T11L/E32-T12L E32-T11L + E39-F2 E32-T11R + E39-F2 E32-T11 + E39-F2 E32-T21L/E32-T22L E32-T223R SpecialE32-T33-S5 Ultracompact, beam ultrafine sleeve E32-T333-S5 models E32-T334-S5 E32-T22S Fine beam (narrow vision field) E32-T24S E32-T16PR E32-T16P E32-T16JR E32-T16J Area sensing E32-T16WR E32-T16W E32-T16 E32-M21 E32-T51 E32-T54 E32-T81R-S Heat resistant E32-T61-S + E39-F2 E32-T61-S + E39-F1 E32-T84S-S E32-T61-S E32-T11F Environment resistive E32-T12F Chemical models E32-T14F resistant E32-T51F E32-T81F-S E32-T51V E32-T51V + E39-F1V Vacuum E32-T54V resistant E32-T54V + E39-F1V E32-T84SV 280 110 60 30 400 240 360 100 90 360 100 75 360 14000 3000 2100 2000 1800 700 500 220 360 200 60 20 5 2.5 1000 700 450 600 390 520 690 920 1500 300 400 130 180 390 3000 700 300 1050 1600 200 700 350 100 600 65 390 250 For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354). 4 E3X-SD Reflective Models (Unit: mm) Model Type E3X-SD@ Standard models Flexible (new standard) Standard models Standard Break resistant Fluorine coating Long distance, high power Ultracompact, ultrafine sleeve E32-D11R/E32-D12R/E32-D15XR/E32-DC200BR (B4R) E32-D14LR E32-D15YR/E32-D15ZR E32-D211R/E32-D21R/E32-D22R/E32-D25XR/ E32-DC200FR (F4R) E32-D24R E32-D25YR/E32-D25ZR E32-DC200/E32-D15X/E32-DC200B (B4) E32-D12 E32-D14L E32-D15Y/E32-D15Z E32-D211/E32-DC200E/E32-D22/E32-D25X/ E32-DC200F (F4) E32-D24 E32-D25Y/E32-D25Z E32-D11/E32-D15XB E32-D21B/E32-D221B E32-D21/E32-D22B E32-D25XB E32-D11U E32-D16 E32-D11L E32-D21L/E32-D22L E32-D33 E32-D331 E32-CC200R E32-CC200 E32-D32L E32-C31/E32-D32 E32-C42 + E39-F3A Coaxial, small spot E32-D32 + E39-F3A Specialbeam models E32-C41 + E39-F3A-5 E32-C31 + E39-F3A-5 E32-C41 + E39-F3B E32-C31 + E39-F3B E32-C31 + E39-F3C Area sensing Environment resistive models E32-D36P1 E32-R21 + E39-R3 (provided) Retro-reflective E32-R16 + E39-R1 (provided) E32-L25/E32-L25A E32-L24S E32-L24L Convergentreflective E32-L25L E32-L86 E32-L16 E32-D51 Heat resistant E32-D81R/E32-D61 E32-D73 E32-D12F Chemical resistant E32-D14F 90 16 20 15 7 4 150 120 40 50 36 15 10 90 35 15 25 90 40 to 400 200 50 10 1.5 75 150 80 40 Spot diameter of 0.1 to 0.6 mm at 6 to 15 mm. Spot diameter of 0.5 to 1 mm at 6 to 15 mm. Spot diameter of 0.1 mm at 7 mm. Spot diameter of 0.5 mm at 7 mm. Spot diameter of 0.2 mm at 17 mm. Spot diameter of 0.5 mm at 17 mm. Spot diameter of 4 mm max. at 0 to 20 mm. 75 10 to 250 150 to 1500 3.3 0 to 4 2 to 6 (center 4) 5.4 to 9 (center 7.2) 4 to 10 0 to 15 120 45 30 50 20 For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E354). 5 E3X-SD I/O Circuit Diagrams Output form Output transistor operation mode Model Incident light No incident light Operation ON indicator OFF (orange) Light-ON Output transistor Load (relay) NPN Output Operation selector Timing charts Output circuit T Brown LIGHT ON (L-ON) ON OFF Operate Load Photoelectric Sensor main circuit Reset (Between brown and black leads) E3X-SD11 E3X-SD6 1 Operation indicator (orange) * Black 4 Control output 12 to 24 VDC Blue Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Dark-ON 3 T DARK ON (D-ON) • M8 Connector Pin Arrangement 2 4 1 3 Note: Pin 2 is not used. Operate Reset (Between brown and black leads) Load (relay) Incident light No incident light Operation ON indicator OFF (orange) ON Output transistor OFF Light-ON T Brown LIGHT ON (L-ON) Operation indicator (orange) Operate Reset (Between blue and black leads) Load (relay) PNP Output E3X-SD41 E3X-SD8 1 Photoelectric Sensor main circuit Black Control output * 4 Load Blue Incident light No incident light T Operation ON indicator OFF (orange) ON Output transistor OFF Operate Load (relay) Reset (Between blue and black leads) Dark-ON 3 DARK ON (D-ON) • M8 Connector Pin Arrangement 2 1 4 3 Note: Pin 2 is not used. Note: Timing Charts for Timer Settings (T: Set Time) ON delay Incident light No incident light ON OFF ON D-ON OFF OFF delay Incident light No incident light T L-ON ON OFF ON D-ON OFF T L-ON T T Plug (Sensor I/O Connector) Terminal number 4 3 2 1 Brown White Blue Black XS3F-M421-402-A XS3F-M421-405-A 6 Wire color 1 2 3 4 XS3F-M422-402-A XS3F-M422-405-A Classification DC Note: Pin 2 is not used. Wire color Connection pin Application Brown 1 Power supply (+V) White 2 --- Blue 3 Power supply (0 V) Black 4 Output 12 to 24 VDC E3X-SD Nomenclature Amplifier Units E3X-SD@ Operation Keys Sensitivity adjustment (UP/DOWN or teaching) Operation Selector Use to switch between Light-ON and Dark-ON Operation Indicator Lock lever Timer switch OFF/D: OFF-delay timer ON/D: ON-delay timer OFF: Timer function is OFF. Incident level indicators TEACH/RUN Mode Selector Used to select TEACH or RUN mode. Safety Precautions WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Caution Do not exceed the rated voltage. Excess voltage may result in malfunction or fire. Do not use an AC power supply. Using an AC power supply may result in rupturing. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safety. 1. Do not use the product in locations where flammable or explosive gas is present. 2. Do not use the product in locations subject to splashing water, oil, or chemicals, or in locations subject to steam. 3. Do not attempt to disassemble, repair, or modify the product. 4. Do not apply voltage or current in excess of the rated ranges. 5. Do not use the product in atmospheres or environments that exceed product ratings. 6. Do not wire the product incorrectly, such as using incorrect power supply polarity. 7. Connect the load properly. 8. Do not short-circuit both ends of the load. 9. Do not use the product if the case is damaged. 10. When disposing of the product, dispose of it as industrial waste. 11. Do not use the product in locations subject to direct sunlight. 12. The surface temperature of the product may rise as a result of the ambient temperature, power supply, or other usage conditions. Use caution when performing maintenance and washing. Failure to do so may result in burn injury. 7 E3X-SD Precautions for Correct Use Do not use the product in atmospheres or environments that exceed product ratings. Amplifier Units ● Designing Communications Hole The hole on the side of the Amplifier Unit is a communications hole for preventing mutual interference when Amplifier Units are mounted side-by-side. The E3X-MC11 Mobile Console (order separately) cannot be used. If an excessive amount of light is received via the Sensor, the mutual interference prevention function may not work. In this case, make the appropriate adjustments using the sensitivity adjuster. The mutual interference prevention function will not operate when the E3X-SD/NA is used side-by-side with E3X-DA-N models. ● Mounting DIN Track Mounting/Removal Mounting Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN track. Fiber Connection and Disconnection The E3X Amplifier Unit has a lock lever. Connect or disconnect the fibers to or from the E3X Amplifier Unit using the following procedures: 1. Connection Open the Protective Cover, insert the fibers according to the fiber insertion marks on the side of the Amplifier Unit, and lower the lock lever. Insertion position Lock lever Fiber Fiber insertion mark 2. Disconnection Remove the Protective Cover and raise the lock lever to pull out the fiber. Protective Cover Locked 2. Slide the Amplifier Units together, line up the clips, and press the Amplifier Units together until they click into place. 10.7 mm Unlocked Note:To maintain the fiber properties, confirm that the lock is released before removing the fiber. 3. Precautions for Fiber Connection/Disconnection Be sure to lock or unlock the lock lever within an ambient temperature range between −10°C and 40°C. Clip Click into place Removing Amplifier Units Slide Amplifier Units away from each other, and remove from the DIN track one at a time. (Do not attempt to remove Amplifier Units from the DIN track without separating them first.) Note 1. The specifications for ambient temperature will vary according to the number of Amplifier Units used together. For details, refer to Ratings and Specifications. 2. Always turn OFF the power supply before mounting or removing Amplifier Units. 8 ● Operating Environment Ambient Conditions If dust or dirt adhere to the hole for optical communications, it may prevent normal communications. Be sure to remove any dust or dirt before using the Units. ● Other Protective Cover Be sure to mount the Protective Cover before use. E3X-SD Amplifier Units with Connectors ● Mounting Mounting Connectors 1. Insert the Master or Slave Connector into the Amplifier Unit until it clicks into place. Mounting End Plate (PFP-M) Depending on how it is mounted, an Amplifier Unit may move during operation. In this case, use an End Plate. Before mounting an End Plate, remove the clip from the master Amplifier Unit using a nipper or similar tool. Insert 2. Join Amplifier Units together as required after all the Master and Slave Connectors have been inserted. 3. Attach the stickers (provided as accessories) to the sides of Master and Slave Connectors that are not connected to other Connectors. Clip The clip can also be removed using the following mechanism, which is incorporated in the construction of the section underneath the clip. 1. Insert the clip to be removed into the slit underneath the clip on another Amplifier Unit. Sticker Sticker Note: Attach the stickers to the sides with grooves. Removing Connectors 1. Slide the slave Amplifier Unit for which the Connector is to be removed away from the rest of the group. 2. After the Amplifier Unit has been separated, press down on the lever on the Connector and remove it. (Do not attempt to remove Connectors without separating them from other Amplifier Units first.) Press down Lever 2. Remove the clip by rotating the Amplifier Unit. Rotate Remove Pull Strengths for Connectors (Including Cables) E3X-CN11: 30 N max. E3X-CN12: 12 N max. 9 E3X-SD Dimensions (Unit: mm) Amplifier Units Amplifier Units with Cables 10 E3X-SD11 E3X-SD41 15 Vinyl-insulated round cable 4 dia. cable / 3 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Operation indicator DIN track mounting 3 128.95 180° 93.75 Hole for optical communications 31.5 8 (16.5) 10.7 10.75 Two, 2.4 dia. 3.4 2.4 13 Multiple connection diagram 4 30.4 End Plate (sold separately) PFP-M 12.4 L 64.3 Center of DIN track DIN track (sold separately) PFP-@N 10 Fiber Attachment mounted (E39-F9) 10 10 The number of expansion L (mm) 1 10 2 20 3 30 4 40 5 50 6 60 7 70 8 80 9 90 10 100 With Mounting Bracket Attached 3 128.95 180° 93.75 Hole for optical communications 31.5 8 (16.5) 10.7 10.75 Two, 2.4 dia. 3.4 2.4 Two, 3.2 dia. holes 4.3 13 (9.4) 4 16 64.3 Mounting Bracket (E39-L143) SUS304 stainless steel Mounting Holes Two, M3 3.4 4.4 16 22.4 16 Fiber Attachment mounted (E39-F9) 10 E3X-SD Amplifier Units with Connectors E3X-SD6 10 E3X-SD8 15 Operation indicator DIN track mounting 3 128.95 180° 93.75 31.5 8 Hole for optical communications A dia. (16.5) 12.95 10.7 Two, 2.4 dia. 3.4 Multiple connection diagram 13 30.4 End Plate (sold separately) PFP-M 12.4 L 64.3 Center of DIN track DIN track (sold separately) PFP-@N 10 Fiber Attachment mounted (E39-F9) 10 The number of expansion L (mm) 1 10 2 20 * Cable Diameters E3X-CN11 (3 conductors) 4.0-mm dia. 3 30 E3X-CN12 (1 conductor) 2.6-mm dia. 4 40 5 50 6 60 7 70 8 80 10 9 90 10 100 With Mounting Bracket Attached 3 128.95 180° 93.75 31.5 8 Hole for optical communications A dia. (16.5) 12.95 10.7 Two, 2.4 dia. 3.4 Two, 3.2 dia. holes 4.3 13 (9.4) 16 64.3 Mounting Bracket (E39-L143) SUS304 stainless steel Mounting Holes Two, M3 3.4 4.4 16 22.4 16 Fiber Attachment mounted (E39-F9) 11 E3X-SD Amplifier Unit Connectors Master Connector E3X-CN11 2,000 +500 Edge of amplifier (7) * * E3X-CN11: 4 dia. cable / 3 conductors / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Slave Connector E3X-CN12 2,000 +500 Edge of amplifier (7) * * E3X-CN12: 2.6 dia. cable / 1 conductor / Standard length: 2 m (Conductor cross section: 0.2 mm2 (AWG24), Insulator diameter: 1.1 mm) Accessories (Order Separately) Mounting Brackets E39-L143 34.8 22 16 2.5 (10.3) 3 Mounting Holes Two, M3 7.3 5.3 26.8 Two, 3.2 dia. 3 16 7 16±0.1 3 Four, R1.7 3.4 10.3 10 max. 7 Material: Stainless steel (SUS304) 1 3.4 End Plates PFP-M 11.5 1 50 M4 × 8 panhead screw 10 M4 spring washer 4.8 6.2 10 1 1.3 1.8 35.5 1.8 35.3 For information on Fiber Units, refer to the E32 Series Fiber Sensor Best Selection (Cat. No. E353). 12 E3X-SD Operating Procedure E3X-SD@ 1 Displays A 7-segment display showing excess gain is provided in addition to the orange operation indicator. Use these when adjusting the light axis and setting the sensitivity at setup. Display/indicator status (for L/ON) Excess gain Description 999% (10 times) 110% min. Stable incident light Operation indicator Excess gain display 100% 0% 90% to 110% Unstable incident light or Unstable interrupted light 90% max. Stable interrupted light 2 Sensitivity Setting The sensitivity can be set with the UP and DOWN Keys similar to using an adjuster knob. The sensitivity can also be easily set by using the following three teaching functions. 2-1. Maximum Sensitivity Setting The sensitivity can be set to the maximum. This is the optimal setting for resistance against the effects of dust. Operation description Set the TEACH/RUN selector switch to TEACH. Press the UP Key for 3 s min. Set the TEACH/RUN selector switch to RUN (start of measurement). Switch/Key Display TEACH RUN UP TEACH RUN 2-2. Teaching with/without a Workpiece Two points (one with the workpiece and the other without) are detected, and the operating level is set to the midpoint. Operation description Set the TEACH/RUN selector switch to TEACH. Switch/Key Press the UP Key with the workpiece present. UP Press the UP Key with the workpiece not present. UP Set the TEACH/RUN selector switch to RUN (start of measurement). Display TEACH RUN TEACH RUN 2-3. Automatic Teaching Changes within a time are detected, and the operating level is set to the midpoint between the maximum and the minimum values of the changes. This setting is optimal for when the workpieces cannot be stopped. Operation description Set the TEACH/RUN selector switch to TEACH. Switch/Key Display TEACH RUN UP Press the UP Key. Hold down the UP Key during UP detection. Let the workpiece pass while the key is held down. Set the TEACH/RUN selector TEACH RUN switch to RUN (start of measurement). 13 MEMO 14 E3X-SD READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON’s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON’S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer’s application or use of the product. At the customer’s request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: • Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. • Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. • Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof. COPYRIGHT AND COPY PERMISSION This document shall not be copied for sales or promotions without permission. This document is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this document in any manner, for any other purpose. If copying or transmitting this document to another, please copy or transmit it in its entirety. This document provides information mainly for selecting suitable models. Please read the Instruction sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. OMRON Corporation Industrial Automation Company Authorized Distributor: Tokyo, JAPAN Contact: www.ia.omron.com Regional Headquarters OMRON EUROPE B.V. Sensor Business Unit Carl-Benz-Str. 4, D-71154 Nufringen, Germany Tel: (49) 7032-811-0/Fax: (49) 7032-811-199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg, IL 60173-5302 U.S.A. Tel: (1) 847-843-7900/Fax: (1) 847-843-7787 OMRON ASIA PACIFIC PTE. LTD. No. 438A Alexandra Road # 05-05/08 (Lobby 2), Alexandra Technopark, Singapore 119967 Tel: (65) 6835-3011/Fax: (65) 6835-2711 OMRON (CHINA) CO., LTD. Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 © OMRON Corporation 2009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_2_1_0114 Cat. No. E388-E1-02 0410