EE06 Series Small Size Transmitter for Humidity and Temperature EE06 series are compact transmitters for humidity, and combined humidity/temperature measurement with excellent price / performance ratio. They are optimised for OEM applications and available with or without housing. With appropriate filter cap EE06 can operate successfully even in harsh environments. The analogue output for both humidity and temperature is 0-1 V. The temperature output signal can be active or passive. The very small dimensions, low energy consumption and supply voltages down to 4.5 V allow cost-effective and easy positioning of the transmitters. EE06 T ypical A pplica tions Fea tur es very small dimensions excellent price-performance-ratio long term stability easy installation low energy consumption humidifiers and dehumidifiers climate controls in museums, hotels monitoring of storage rooms photostatic machines control meteorological applications Tec hnical Da ta Measuring values Relative humidity Sensor Output appropriate 0...100% RH Working range Accuracy at 20°C (68°F), 12V DC Temperature dependence model F/FT model FP HC101 0-1 V -0.2 mA < IL < 0.2 mA model A 0...100% RH model C model B 0...95% RH ±3% RH (0...95% RH) d RH = -0.00035 x RH x (T-20°C) d RH = typ. (-0.003 x RH + 0.01) x (T-20°C) 0...100% RH Temperature (active output) Sensor Output appropriate -40...60°C (-40...140°F) Accuracy at 12V DC ∆°Χ Pt1000 (class A, DIN EN 60751) 0-1 V -0.2 mA < IL < 0.2 mA °C Temperature (passive output) Type of T-Sensor please see ordering guide General Supply voltage Current consumption Housing Sensor protection Electromagnetic compatibility Temperature range 4.5V DC - 30V DC typ. 1.5 mA Polycarbonat / IP65 (Model A) in vertical mounting (filter cap upside) membrane filter, plastic grid, metal grid filter EN 61000-6-3 EN 61000-6-1 FCC Part15 ClassB ICES-003 ClassB working temperature: -40...60°C (-40...140°F) storage temperature: -40...65°C (-40...149°F) EE06 v2.2 37 Housing dimensions (mm) 1 mm = 0.03937” / 1” = 25.4 mm Type B Type A 2 Ø1 34 2 Ø1 Type C 34 34 82 60 2 Ø1 80 7 M10x1 cable length standard = 500mm (19.7”) cable length standard = 200mm (7.9”) cable length standard = 500mm (19.7”) Connection Dia g r am power supply 4.5...30V DC + +V (white) - GND (brown) V V RH (green) T (yellow) power supply 4.5...30V DC + +V (white) - GND (brown) V W RH (green) Tpassive1 (yellow) Tpassive2 (gray) Or dering Guide MODEL OUTPUT T-SENSOR humidity and temperature (FT) humidity (F) humidity and temperature passive (FP) 0-1V (only passive) (1) Pt 100 DIN A Pt 100 DIN B Pt 1000 DIN A Pt 1000 DIN B NTC 10K at 25°C (A) (B) (C) (D) (E) TYPE FILTER CABLE LENGTH with housing (A) without housing (B) with thread (C) membrane filter plastic grid metal grid filter (Type A + C) (1) (4) (6) 0.5m (1.6ft) 1.5m (4.9ft) 3m (9.8ft) 5m (16.4ft) 10m (32.8ft) (no code) (K150) (K300) (K500) (K1000) EE06- Accessories - radiation shield (for more information please refer to data sheet “Accessories”) (HA010502) Or der Example EE06-FT1A1-K300 model: output: housing: filter: cable length EE06 38 humidity and temperature 0-1 V with housing membrane filter 3m (9.8ft)