FCI EGFZ20G

EGFZ20A . . . 20M Series
Preliminary Data Sheet 2.0 Amp Glass Passivated
Sintered Fast Efficient
Rectifiers
Mechanical Dimensions
Description
4.06/4.60
3.30/3.90
Cathode
Package
‘‘SMB’’
5.10/5/58
.11/.30
1.65/2.19
1.91/2.41
.01/.20
1.90/2.15
Features
n LOWEST COST FOR GLASS SINTERED
FAST EFFICIENT CONSTRUCTION
n 2.0 AMP OPERATION @ TA = 55°C, WITH
NO THERMAL RUNAWAY
n LOWEST VF FOR GLASS SINTERED
FAST EFFICIENT CONSTRUCTION
n SINTERED GLASS CAVITY-FREE
JUNCTION
n TYPICAL IR < 100 nAmps
Electrical Characteristics @ 25 o C.
Maximum Ratings
EGFZ20A . . . 20M Series
20A
20B
20D
20G
20J
Units
20K
20M
Peak Repetitive Reverse Voltage...VRRM
50
100
200
400
600
800
1000
Volts
RMS Reverse Voltage...VR(rms)
35
70
140
280
420
560
700
Volts
DC Blocking Voltage...VDC
50
100
200
400
600
800
1000
Volts
Average Forward Rectified Current...I F(av)
@ TL = 55°C (Note 2)
............................................. 2.0 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
8.3mS, ½ Sine Wave Superimposed on Rated Load
............................................. 6 5 ...............................................
Amps
Forward Voltage @ 2.0A...VF
< ............. 1.0 ........... >
Volts
1.3
< .............. 1.7 ............ >
............................................. 5.0 ...............................................
............................................. 1 0 0 ...............................................
µAmps
Typical Junction Capacitance...CJ (Note 1)
............................................. 3 5 ...............................................
pF
Typical Thermal Resistance...RθJA (Note 2)
............................................. 1 6 ...............................................
°C / W
Maximum Reverse Recovery Time...tRR (Note 3)
< ...................... 5 0 ................... > < ............. 7 5 ........... >
nS
Operating & Storage Temperature Range...TJ, TSTRG ......................................... -65 to 150 ..........................................
°C
DC Reverse Current...IR(max)
@ Rated DC Blocking Voltage
TA = 25°C
TA = 125°C
Preliminary Data Sheet 2.0 Amp Glass Passivated
Die Dimension (mils)
Avg. Forward Rectified Current (A)
Forward Current Derating Curve
A
T
D
Glass
G
d
D
96
Ambient Temperature (°°C)
T
11
A
15+1
Typical Junction Capacitance
Non-Repetitive Peak Forward Surge Current
Reverse Voltage (V)
Number of Cycles @ 60 HZ
d
G
64 2+0.5
EGFZ20A . . . 20M Series
Sintered Fast Efficient
Rectifiers
Junction Capacitance (pF)
Typical Instantaneous Forward Characteristics
Typical Reverse Characteristics
Forward Current (A)
Reverse Leakage Current (µ
µ A)
Peak Forward Surge Current (A)
Forward Voltage (V)
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
Percent of Rated Peak Voltage (%)
NOTES: 1. Measured @ 1 MHZ and applied reverse voltage of 4.0V.
2. Thermal Resistance from Junction to Ambient at 3/8" Lead Length, P.C. Board Mounted.
3. Reverse Recovery Condition IF = 0.5A, IR = 1.0A, IRR = 0.25A.
For Capacitive
Load, Derate
Current by 20%.