Jumbo-LED ELJ-830-629 07.05.2008 Radiation Type Technology Case Infrared 4W AlGaAs/AlGaAs Plastic lens, metal case Description 1,5 Ø1,7 Ø11 High-power infrared LED in an aluminium case, with thread socket for easy handling and heat sink mounting 2 4,5 1 Outline: 7,9 H = 12.4 mm (± 0.5) D = 16 mm (± 0.5) 8 Applications Medical appliances, remote control and optical communications, light barriers, measurement systems 2 Ø16 5,08 Ø12,5 rev. 01 13 Thread M10 1 2 Pin 1 – cathode Pin 2 – anode M10 Absolute Maximum Ratings at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Parameter Test сonditions Symbol Value Unit on heat sink IF 1.2 A tp≤100 µs, D = 0,05 IFM 2.0 A Power dissipation on heat sink P 2.8 W Operating temperature range on heat sink Tamb -25 to +100 °C Storage temperature range on heat sink Tstg -25 to +100 °C Junction temperature on heat sink Tj 100 °C Typ Max Unit DC forward current Peak forward current Electrical Characteristics Tamb = 25°C, unless otherwise specified Parameter Test conditions Symbol Min Forward voltage IF = 350 mA VF 1.6 1.9 V Forward voltage* IF = 1000 mA VF 2.0 2.4 V Switching time IF = 350 mA tr , tf 20 ns Reverse voltage IR = 10 µA VR 10 K/W Thermal resistance junction-case RthJC 5 *only recommended on optimal heat sink We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each application by the customers themselves. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 1 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-830-629 07.05.2008 rev. 01 Optical Characteristics at Tamb = 25°C, on heat sink (S ≥ 200 cm²), unless otherwise specified Test Parameter Symbol Min conditions Typ Max Unit Radiant power IF = 350 mA Φe Radiant power* IF = 1000 mA Φe Radiant intensity IF = 350 mA Ιe Radiant intensity* IF = 1000 mA Ιe Peak wavelength IF = 350 mA λp Spectral bandwidth at 50% IF = 350 mA ∆λ0.5 35 nm Full viewing angle IF = 350 mA 2ϕ 20 deg 80 450 820 100 mW 270 mW 750 mW/sr 2100 mW/sr 830 840 nm *only recommended on optimal heat sink Note: All measurements carried out with EPIGAP equipment, on blank aluminium heat sink, S = 180 cm², passive cooling. Measurement results and curve characteristics obtained with other heat sinks may differ. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each application by the customers themselves. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 2 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-830-629 07.05.2008 Radiant Power vs. Forward Current (typical) Normalized to ΦE @IF= 350 mA 3,5 rev. 01 Forward Current vs. ForwardVoltage (typical) 1300 1200 3,0 1100 900 800 2,0 IF (mA) Rel. Radiant Power Φe (rel.) 1000 2,5 1,5 700 600 500 400 1,0 300 200 0,5 100 0 1,2 0,0 0 200 400 600 800 1000 1200 1,4 1,6 Spectral Power Distribution (typical) at IF = 350 mA 2,0 2,2 Typical Wavelength Shift vs. Forward Current (rel. to λP @IF = 350 mA) 12 1,0 10 8 0,8 Wavelength Shift (nm) Rel. Intensity (arb. units) 1,8 UF (V) IF (mA) 0,6 0,4 6 4 2 0 0,2 -2 0,0 700 750 800 850 900 950 Wavelength (nm) 0 200 400 600 800 1000 1200 IF (mA) Ambient Temperature vs. Maximal Forward Current Max. Forward Current (A) 1,5 1,0 0,5 0,0 0 20 40 60 80 100 120 Ambient Temperature (°C) We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each application by the customers themselves. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 3 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-830-629 07.05.2008 rev. 01 Remarks concerning optical radiation safety* This LED may be classified as LED product Class 1 according to standard IEC 60825-1:A2 at low forward current (<100 mA) and continuous operation. Class 1 products are safe to eyes and skin under reasonable predictable conditions. This implicates a direct observation of the light beam by means of optical instruments. This product should be classified as LED product Class 1M according to standard IEC 60825-1:A2 if driven with higher continuous forward current (up to 700 mA). Class 1M products are safe to eyes and skin under normal conditions, even when users look into the light beam directly. Class 1M products produce either a highly divergent beam or a large diameter beam, so only a small part of the whole radiation beam can enter the eye. However, such optical products can be harmful to the retina using magnifying optical instruments. Therefore, users should not incorporate optics that could focus the output into the eyes. If it is intended to operate the LED at very high continuous current (>1 A), this product has to be (potentially) classified as Class 3B LED. Class 3B LEDs may have sufficient power to cause an eye injury both by the direct beam and by reflections therefore these products are considered hazardous to the eye. However, the extent and severity of any eye injury arising from an exposure to the light beam of a Class 3B product will depend upon several factors including the radiant power entering the eye and the duration of the exposure. Nonetheless, adequate precautions should be taken to avoid direct or indirect looking into the beam. *Note: Safety classification of an optical component mainly depends on the intended application and the way the component is being used. Furthermore, all statements made to classification are based on calculations and are only valid for this LED "as it is" and at continuous operation. Using pulsed current or altering the radiation beam with additional optics may lead to different safety classifications. Therefore these remarks should be taken as recommendation and guideline only. INFRARED RADIATION Do not expose to the beam LED Class 3B accord. DIN EN/IEC 60825-1:2001-11 We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each application by the customers themselves. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 4 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545 Jumbo-LED ELJ-830-629 07.05.2008 rev. 01 Handling precautions To prevent damage to the LED during soldering and assembly, following precautions have to be taken into account. a) The bending point of the lead frame should be located at least 2.5 mm away from the body. b) While bending, the base of the lead frame has to be fixed with radio pliers or similar. c) To ensure an adequate strain relief, the lead frames have to be firmly fixed during soldering. d) To avoid any damage of the LED during soldering the lead frames should not be distorted especially when they have been heated e) LEDs are static sensitive devices, so adequate handling precautions have to be taken, e.g. wearing grounding wrist straps. We reserve the right to make changes to improve technical design and may do so without further notice. Parameters can vary in different applications. All operating parameters must be validated for each application by the customers themselves. EPIGAP Optoelektronik GmbH, D-12555 Berlin, Köpenicker Str.325 b, Haus 201 5 of 5 Tel.: +49-30-6576 2543, Fax : +49-30-6576 2545