EN29LV640T/B EN29LV640T/B 64 Megabit (8M x 8-bit / 4M x 16-bit) Flash Memory Boot Sector Flash Memory, CMOS 3.0 Volt-only FEATURES • Single power supply operation - Full voltage range: 2.7 to 3.6 volts read and write operations • Standard DATA# polling and toggle bits feature • High performance - Access times as fast as 70 ns • Erase Suspend / Resume modes: Read and program another Sector during Erase Suspend Mode • Low power consumption (typical values at 5 MHz) - 9 mA typical active read current - 20 mA typical program/erase current - Less than 1 μA current in standby or automatic sleep mode. • Flexible Sector Architecture: - Eight 8-Kbyte sectors, One hundred and twenty-seven 32K-Word / 64K-byte sectors. - 8-Kbyte sectors for Top or Bottom boot. - Sector/Sector Group protection: Hardware locking of sectors to prevent program or erase operations within individual sectors Additionally, temporary Sector Group Unprotect allows code changes in previously locked sectors. • - High performance program/erase speed Word program time: 8µs typical Sector erase time: 500ms typical Chip erase time: 64s typical • JEDEC Standard compatible • Unlock Bypass Program command supported • Support JEDEC Common Flash Interface (CFI). • Low Vcc write inhibit < 2.5V • Minimum 100K program/erase endurance cycles. • RESET# hardware reset pin - Hardware method to reset the device to read mode. • WP#/ACC input pin - Write Protect (WP#) function allows protection of outermost two boot sectors, regardless of sector protect status - Acceleration (ACC) function provides accelerated program times • Package Options - 48-pin TSOP (Type 1) - 48 ball 6mm x 8mm FBGA • Commercial and Industrial Temperature Range. GENERAL DESCRIPTION The EN29LV640T/B is a 64-Megabit, electrically erasable, read/write non-volatile flash memory, organized as 8,388,608 bytes or 4,194,304 words. Any word can be programmed typically in 8µs. The EN29LV640T/B features 3.0V voltage read and write operation, with access times as fast as 70ns to eliminate the need for WAIT states in high-performance microprocessor systems. The EN29LV640T/B has separate Output Enable (OE#), Chip Enable (CE#), and Write Enable (WE#) controls, which eliminate bus contention issues. This device is designed to allow either single Sector or full Chip erase operation, where each Sector can be individually protected against program/erase operations or temporarily unprotected to erase or program. The device can sustain a minimum of 100K program/erase cycles on each Sector. . This Data Sheet may be revised by subsequent versions 1 or modifications due to changes in technical specifications. ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B CONNECTION DIAGRAMS This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 2 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B LOGIC DIAGRAM TABLE 1. PIN DESCRIPTION Pin Name Function A0-A21 22 Address inputs DQ0-DQ14 15 Data Inputs/Outputs DQ15 / A-1 DQ15 (data input/output, in word mode), A-1 (LSB address input, in byte mode) CE# Chip Enable OE# Output Enable WE# Write Enable WP#/ACC Write Protect / Acceleration Pin RESET# Hardware Reset Pin BYTE# Byte/Word mode selection RY/BY# Ready/Busy Output Vcc Supply Voltage (2.7-3.6V) Vss Ground NC Not Connected to anything This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 3 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B ORDERING INFORMATION EN29LV640 T― 70 T C P PACKAGING CONTENT (Blank) = Conventional P = Pb Free TEMPERATURE RANGE C = Commercial (0°C to +70°C) I = Industrial (-40°C to +85°C) PACKAGE T = 48-pin TSOP B = 48-Ball Fine Pitch Ball Grid Array (FBGA) 0.80mm pitch, 6mm x 8mm package SPEED 70 = 70ns 90 = 90ns BOOT CODE SECTOR ARCHITECTURE T = Top boot Sector B = Bottom boot Sector BASE PART NUMBER EN = EON Silicon Solution Inc. 29LV = FLASH, 3V Read, Program and Erase 640 = 64 Megabit (8M x 8 / 4M x 16) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 4 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Table 2A. Top Boot Sector Address Tables (EN29LV640T) U 64/32 Address Range (h) Byte mode (x8) 000000–00FFFF Address Range (h) Word Mode (x16) 000000–007FFF 0000001xxx 64/32 010000–01FFFF 008000–00FFFF SA2 0000010xxx 64/32 020000–02FFFF 010000–017FFF SA3 0000011xxx 64/32 030000–03FFFF 018000–01FFFF SA4 0000100xxx 64/32 040000–04FFFF 020000–027FFF SA5 0000101xxx 64/32 050000–05FFFF 028000–02FFFF SA6 0000110xxx 64/32 060000–06FFFF 030000–037FFF SA7 0000111xxx 64/32 070000–07FFFF 038000–03FFFF SA8 0001000xxx 64/32 080000–08FFFF 040000–047FFF SA9 0001001xxx 64/32 090000–09FFFF 048000–04FFFF SA10 0001010xxx 64/32 0A0000–0AFFFF 050000–057FFF SA11 0001011xxx 64/32 0B0000–0BFFFF 058000–05FFFF SA12 0001100xxx 64/32 0C0000–0CFFFF 060000–067FFF SA13 0001101xxx 64/32 0D0000–0DFFFF 068000–06FFFF SA14 0001110xxx 64/32 0E0000–0EFFFF 070000–077FFF SA15 0001111xxx 64/32 0F0000–0FFFFF 078000–07FFFF SA16 0010000xxx 64/32 100000–10FFFF 080000–087FFF SA17 0010001xxx 64/32 110000–11FFFF 088000–08FFFF SA18 0010010xxx 64/32 120000–12FFFF 090000–097FFF SA19 0010011xxx 64/32 130000–13FFFF 098000–09FFFF SA20 0010100xxx 64/32 140000–14FFFF 0A0000–0A7FFF SA21 0010101xxx 64/32 150000–15FFFF 0A8000–0AFFFF SA22 0010110xxx 64/32 160000–16FFFF 0B0000–0B7FFF SA23 0010111xxx 64/32 170000–17FFFF 0B8000–0BFFFF SA24 0011000xxx 64/32 180000–18FFFF 0C0000–0C7FFF SA25 0011001xxx 64/32 190000–19FFFF 0C8000–0CFFFF SA26 0011010xxx 64/32 1A0000–1AFFFF 0D0000–0D7FFF SA27 0011011xxx 64/32 1B0000–1BFFFF 0D8000–0DFFFF SA28 0011100xxx 64/32 1C0000–1CFFFF 0E0000–0E7FFF SA29 0011101xxx 64/32 1D0000–1DFFFF 0E8000–0EFFFF SA30 0011110xxx 64/32 1E0000–1EFFFF 0F0000–0F7FFF SA31 0011111xxx 64/32 1F0000–1FFFFF 0F8000–0FFFFF SA32 0100000xxx 64/32 200000–20FFFF 100000–107FFF SA33 0100001xxx 64/32 210000–21FFFF 108000–10FFFF SA34 0100010xxx 64/32 220000–22FFFF 110000–117FFF SA35 0100011xxx 64/32 230000–23FFFF 118000–11FFFF SA36 0100100xxx 64/32 240000–24FFFF 120000–127FFF SA37 0100101xxx 64/32 250000–25FFFF 128000–12FFFF Sector A21 – A12 Sector Size (Kbytes / Kwords) SA0 0000000xxx SA1 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 5 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SA38 0100110xxx 64/32 260000–26FFFF 130000–137FFF SA39 0100111xxx 64/32 270000–27FFFF 138000–13FFFF SA40 0101000xxx 64/32 280000–28FFFF 140000–147FFF SA41 0101001xxx 64/32 290000–29FFFF 148000–14FFFF SA42 0101010xxx 64/32 2A0000–2AFFFF 150000–157FFF SA43 0101011xxx 64/32 2B0000–2BFFFF 158000–15FFFF SA44 0101100xxx 64/32 2C0000–2CFFFF 160000–167FFF SA45 0101101xxx 64/32 2D0000–2DFFFF 168000–16FFFF SA46 0101110xxx 64/32 2E0000–2EFFFF 170000–177FFF SA47 0101111xxx 64/32 2F0000–2FFFFF 178000–17FFFF SA48 0110000xxx 64/32 300000–30FFFF 180000–187FFF SA49 0110001xxx 64/32 310000–31FFFF 188000–18FFFF SA50 0110010xxx 64/32 320000–32FFFF 190000–197FFF SA51 0110011xxx 64/32 330000–33FFFF 198000–19FFFF SA52 0110100xxx 64/32 340000–34FFFF 1A0000–1A7FFF SA53 0110101xxx 64/32 350000–35FFFF 1A8000–1AFFFF SA54 0110110xxx 64/32 360000–36FFFF 1B0000–1B7FFF SA55 0110111xxx 64/32 370000–37FFFF 1B8000–1BFFFF SA56 0111000xxx 64/32 380000–38FFFF 1C0000–1C7FFF SA57 0111001xxx 64/32 390000–39FFFF 1C8000–1CFFFF SA58 0111010xxx 64/32 3A0000–3AFFFF 1D0000–1D7FFF SA59 0111011xxx 64/32 3B0000–3BFFFF 1D8000–1DFFFF SA60 0111100xxx 64/32 3C0000–3CFFFF 1E0000–1E7FFF SA61 0111101xxx 64/32 3D0000–3DFFFF 1E8000–1EFFFF SA62 0111110xxx 64/32 3E0000–3EFFFF 1F0000–1F7FFF SA63 0111111xxx 64/32 3F0000–3FFFFF 1F8000–1FFFFF SA64 1000000xxx 64/32 400000–40FFFF 200000–207FFF SA65 1000001xxx 64/32 410000–41FFFF 208000–20FFFF SA66 1000010xxx 64/32 420000–42FFFF 210000–217FFF SA67 1000011xxx 64/32 430000–43FFFF 218000–21FFFF SA68 1000100xxx 64/32 440000–44FFFF 220000–227FFF SA69 1000101xxx 64/32 450000–45FFFF 228000–22FFFF SA70 1000110xxx 64/32 460000–46FFFF 230000–237FFF SA71 1000111xxx 64/32 470000–47FFFF 238000–23FFFF SA72 1001000xxx 64/32 480000–48FFFF 240000–247FFF SA73 1001001xxx 64/32 490000–49FFFF 248000–24FFFF SA74 1001010xxx 64/32 4A0000–4AFFFF 250000–257FFF SA75 1001011xxx 64/32 4B0000–4BFFFF 258000–25FFFF SA76 1001100xxx 64/32 4C0000–4CFFFF 260000–267FFF SA77 1001101xxx 64/32 4D0000–4DFFFF 268000–26FFFF SA78 1001110xxx 64/32 4E0000–4EFFFF 270000–277FFF SA79 1001111xxx 64/32 4F0000–4FFFFF 278000–27FFFF This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 6 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SA80 1010000xxx 64/32 500000–50FFFF 280000–287FFF SA81 1010001xxx 64/32 510000–51FFFF 288000–28FFFF SA82 1010010xxx 64/32 520000–52FFFF 290000–297FFF SA83 1010011xxx 64/32 530000–53FFFF 298000–29FFFF SA84 1010100xxx 64/32 540000–54FFFF 2A0000–2A7FFF SA85 1010101xxx 64/32 550000–55FFFF 2A8000–2AFFFF SA86 1010110xxx 64/32 560000–56FFFF 2B0000–2B7FFF SA87 1010111xxx 64/32 570000–57FFFF 2B8000–2BFFFF SA88 1011000xxx 64/32 580000–58FFFF 2C0000–2C7FFF SA89 1011001xxx 64/32 590000–59FFFF 2C8000–2CFFFF SA90 1011010xxx 64/32 5A0000–5AFFFF 2D0000–2D7FFF SA91 1011011xxx 64/32 5B0000–5BFFFF 2D8000–2DFFFF SA92 1011100xxx 64/32 5C0000–5CFFFF 2E0000–2E7FFF SA93 1011101xxx 64/32 5D0000–5DFFFF 2E8000–2EFFFF SA94 1011110xxx 64/32 5E0000–5EFFFF 2F0000–2F7FFF SA95 1011111xxx 64/32 5F0000–5FFFFF 2F8000–2FFFFF SA96 1100000xxx 64/32 600000–60FFFF 300000–307FFF SA97 1100001xxx 64/32 610000–61FFFF 308000–30FFFF SA98 1100010xxx 64/32 620000–62FFFF 310000–317FFF SA99 1100011xxx 64/32 630000–63FFFF 318000–31FFFF SA100 1100100xxx 64/32 640000–64FFFF 320000–327FFF SA101 1100101xxx 64/32 650000–65FFFF 328000–32FFFF SA102 1100110xxx 64/32 660000–66FFFF 330000–337FFF SA103 1100111xxx 64/32 670000–67FFFF 338000–33FFFF SA104 1101000xxx 64/32 680000–68FFFF 340000–347FFF SA105 1101001xxx 64/32 690000–69FFFF 348000–34FFFF SA106 1101010xxx 64/32 6A0000–6AFFFF 350000–357FFF SA107 1101011xxx 64/32 6B0000–6BFFFF 358000–35FFFF SA108 1101100xxx 64/32 6C0000–6CFFFF 360000–367FFF SA109 1101101xxx 64/32 6D0000–6DFFFF 368000–36FFFF SA110 1101110xxx 64/32 6E0000–6EFFFF 370000–377FFF SA111 1101111xxx 64/32 6F0000–6FFFFF 378000–37FFFF SA112 1110000xxx 64/32 700000–70FFFF 380000–387FFF SA113 1110001xxx 64/32 710000–71FFFF 388000–38FFFF SA114 1110010xxx 64/32 720000–72FFFF 390000–397FFF SA115 1110011xxx 64/32 730000–73FFFF 398000–39FFFF SA116 1110100xxx 64/32 740000–74FFFF 3A0000–3A7FFF SA117 1110101xxx 64/32 750000–75FFFF 3A8000–3AFFFF SA118 1110110xxx 64/32 760000–76FFFF 3B0000–3B7FFF SA119 1110111xxx 64/32 770000–77FFFF 3B8000–3BFFFF SA120 1111000xxx 64/32 780000–78FFFF 3C0000–3C7FFF SA121 1111001xxx 64/32 790000–79FFFF 3C8000–3CFFFF This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 7 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SA122 1111010xxx 64/32 7A0000–7AFFFF 3D0000–3D7FFF SA123 1111011xxx 64/32 7B0000–7BFFFF 3D8000–3DFFFF SA124 1111100xxx 64/32 7C0000–7CFFFF 3E0000–3E7FFF SA125 1111101xxx 64/32 7D0000–7DFFFF 3E8000–3EFFFF SA126 1111110xxx 64/32 7E0000–7EFFFF 3F0000–3F7FFF SA127 1111111000 8/4 7F0000–7F1FFF 3F8000–3F8FFF SA128 1111111001 8/4 7F2000–7F3FFF 3F9000–3F9FFF SA129 1111111010 8/4 7F4000–7F5FFF 3FA000–3FAFFF SA130 1111111011 8/4 7F6000–7F7FFF 3FB000–3FBFFF SA131 1111111100 8/4 7F8000–7F9FFF 3FC000–3FCFFF SA132 1111111101 8/4 7FA000–7FBFFF 3FD000–3FDFFF SA133 1111111110 8/4 7FC000–7FDFFF 3FE000–3FEFFF SA134 1111111111 8/4 7FE000–7FFFFF 3FF000–3FFFFF Note: The address bus is A21:A-1 in byte mode where BYTE# = V IL or A20:A0 in word mode where BYTE# = V IH B B B B Table 2B. Bottom Boot Sector Address Tables (EN29LV640B) U 8/4 Address Range (h) Byte mode (x8) 000000–001FFF Address Range (h) Word Mode (x16) 000000–000FFF 0000000001 8/4 002000–003FFF 001000–001FFF SA2 0000000010 8/4 004000–005FFF 002000–002FFF SA3 0000000011 8/4 006000–007FFF 003000–003FFF Sector A21 – A12 Sector Size (Kbytes / Kwords) SA0 0000000000 SA1 SA4 0000000100 8/4 008000–009FFF 004000–004FFF SA5 0000000101 8/4 00A000–00BFFF 005000–005FFF SA6 0000000110 8/4 00C000–00DFFF 006000–006FFF SA7 0000000111 8/4 00E000–00FFFF 007000–007FFF SA8 0000001xxx 64/32 010000–01FFFF 008000–00FFFF SA9 0000010xxx 64/32 020000–02FFFF 010000–017FFF SA10 0000011xxx 64/32 030000–03FFFF 018000–01FFFF SA11 0000100xxx 64/32 040000–04FFFF 020000–027FFF SA12 0000101xxx 64/32 050000–05FFFF 028000–02FFFF SA13 0000110xxx 64/32 060000–06FFFF 030000–037FFF SA14 0000111xxx 64/32 070000–07FFFF 038000–03FFFF SA15 0001000xxx 64/32 080000–08FFFF 040000–047FFF SA16 0001001xxx 64/32 090000–09FFFF 048000–04FFFF SA17 0001010xxx 64/32 0A0000–0AFFFF 050000–057FFF This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 8 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SA18 0001011xxx 64/32 0B0000–0BFFFF 058000–05FFFF SA19 0001100xxx 64/32 0C0000–0CFFFF 060000–067FFF SA20 0001101xxx 64/32 0D0000–0DFFFF 068000–06FFFF SA21 0001110xxx 64/32 0E0000–0EFFFF 070000–077FFF SA22 0001111xxx 64/32 0F0000–0FFFFF 078000–07FFFF SA23 0010000xxx 64/32 100000–10FFFF 080000–087FFF SA24 0010001xxx 64/32 110000–11FFFF 088000–08FFFF SA25 0010010xxx 64/32 120000–12FFFF 090000–097FFF SA26 0010011xxx 64/32 130000–13FFFF 098000–09FFFF SA27 0010100xxx 64/32 140000–14FFFF 0A0000–0A7FFF SA28 0010101xxx 64/32 150000–15FFFF 0A8000–0AFFFF SA29 0010110xxx 64/32 160000–16FFFF 0B0000–0B7FFF SA30 0010111xxx 64/32 170000–17FFFF 0B8000–0BFFFF SA31 0011000xxx 64/32 180000–18FFFF 0C0000–0C7FFF SA32 0011001xxx 64/32 190000–19FFFF 0C8000–0CFFFF SA33 0011010xxx 64/32 1A0000–1AFFFF 0D0000–0D7FFF SA34 0011011xxx 64/32 1B0000–1BFFFF 0D8000–0DFFFF SA35 0011100xxx 64/32 1C0000–1CFFFF 0E0000–0E7FFF SA36 0011101xxx 64/32 1D0000–1DFFFF 0E8000–0EFFFF SA37 0011110xxx 64/32 1E0000–1EFFFF 0F0000–0F7FFF SA38 0011111xxx 64/32 1F0000–1FFFFF 0F8000–0FFFFF SA39 0100000xxx 64/32 200000–20FFFF 100000–107FFF SA40 0100001xxx 64/32 210000–21FFFF 108000–10FFFF SA41 0100010xxx 64/32 220000–22FFFF 110000–117FFF SA42 0100011xxx 64/32 230000–23FFFF 118000–11FFFF SA43 0100100xxx 64/32 240000–24FFFF 120000–127FFF SA44 0100101xxx 64/32 250000–25FFFF 128000–12FFFF SA45 0100110xxx 64/32 260000–26FFFF 130000–137FFF SA46 0100111xxx 64/32 270000–27FFFF 138000–13FFFF SA47 0101000xxx 64/32 280000–28FFFF 140000–147FFF SA48 0101001xxx 64/32 290000–29FFFF 148000–14FFFF SA49 0101010xxx 64/32 2A0000–2AFFFF 150000–157FFF SA50 0101011xxx 64/32 2B0000–2BFFFF 158000–15FFFF SA51 0101100xxx 64/32 2C0000–2CFFFF 160000–167FFF SA52 0101101xxx 64/32 2D0000–2DFFFF 168000–16FFFF SA53 0101110xxx 64/32 2E0000–2EFFFF 170000–177FFF SA54 0101111xxx 64/32 2F0000–2FFFFF 178000–17FFFF SA55 0110000xxx 64/32 300000–30FFFF 180000–187FFF SA56 0110001xxx 64/32 310000–31FFFF 188000–18FFFF SA57 0110010xxx 64/32 320000–32FFFF 190000–197FFF SA58 0110011xxx 64/32 330000–33FFFF 198000–19FFFF SA59 0110100xxx 64/32 340000–34FFFF 1A0000–1A7FFF This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 9 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SA60 0110101xxx 64/32 350000–35FFFF 1A8000–1AFFFF SA61 0110110xxx 64/32 360000–36FFFF 1B0000–1B7FFF SA62 0110111xxx 64/32 370000–37FFFF 1B8000–1BFFFF SA63 0111000xxx 64/32 380000–38FFFF 1C0000–1C7FFF SA64 0111001xxx 64/32 390000–39FFFF 1C8000–1CFFFF SA65 0111010xxx 64/32 3A0000–3AFFFF 1D0000–1D7FFF SA66 0111011xxx 64/32 3B0000–3BFFFF 1D8000–1DFFFF SA67 0111100xxx 64/32 3C0000–3CFFFF 1E0000–1E7FFF SA68 0111101xxx 64/32 3D0000–3DFFFF 1E8000–1EFFFF SA69 0111110xxx 64/32 3E0000–3EFFFF 1F0000–1F7FFF SA70 0111111xxx 64/32 3F0000–3FFFFF 1F8000–1FFFFF SA71 1000000xxx 64/32 400000–40FFFF 200000–207FFF SA72 1000001xxx 64/32 410000–41FFFF 208000–20FFFF SA73 1000010xxx 64/32 420000–42FFFF 210000–217FFF SA74 1000011xxx 64/32 430000–43FFFF 218000–21FFFF SA75 1000100xxx 64/32 440000–44FFFF 220000–227FFF SA76 1000101xxx 64/32 450000–45FFFF 228000–22FFFF SA77 1000110xxx 64/32 460000–46FFFF 230000–237FFF SA78 1000111xxx 64/32 470000–47FFFF 238000–23FFFF SA79 1001000xxx 64/32 480000–48FFFF 240000–247FFF SA80 1001001xxx 64/32 490000–49FFFF 248000–24FFFF SA81 1001010xxx 64/32 4A0000–4AFFFF 250000–257FFF SA82 1001011xxx 64/32 4B0000–4BFFFF 258000–25FFFF SA83 1001100xxx 64/32 4C0000–4CFFFF 260000–267FFF SA84 1001101xxx 64/32 4D0000–4DFFFF 268000–26FFFF SA85 1001110xxx 64/32 4E0000–4EFFFF 270000–277FFF SA86 1001111xxx 64/32 4F0000–4FFFFF 278000–27FFFF SA87 1010000xxx 64/32 500000–50FFFF 280000–287FFF SA88 1010001xxx 64/32 510000–51FFFF 288000–28FFFF SA89 1010010xxx 64/32 520000–52FFFF 290000–297FFF SA90 1010011xxx 64/32 530000–53FFFF 298000–29FFFF SA91 1010100xxx 64/32 540000–54FFFF 2A0000–2A7FFF SA92 1010101xxx 64/32 550000–55FFFF 2A8000–2AFFFF SA93 1010110xxx 64/32 560000–56FFFF 2B0000–2B7FFF SA94 1010111xxx 64/32 570000–57FFFF 2B8000–2BFFFF SA95 1011000xxx 64/32 580000–58FFFF 2C0000–2C7FFF SA96 1011001xxx 64/32 590000–59FFFF 2C8000–2CFFFF SA97 1011010xxx 64/32 5A0000–5AFFFF 2D0000–2D7FFF SA98 1011011xxx 64/32 5B0000–5BFFFF 2D8000–2DFFFF SA99 1011100xxx 64/32 5C0000–5CFFFF 2E0000–2E7FFF SA100 1011101xxx 64/32 5D0000–5DFFFF 2E8000–2EFFFF SA101 1011110xxx 64/32 5E0000–5EFFFF 2F0000–2F7FFF This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 10 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SA102 1011111xxx 64/32 5F0000–5FFFFF 2F8000–2FFFFF SA103 1100000xxx 64/32 600000–60FFFF 300000–307FFF SA104 1100001xxx 64/32 610000–61FFFF 308000–30FFFF SA105 1100010xxx 64/32 620000–62FFFF 310000–317FFF SA106 1100011xxx 64/32 630000–63FFFF 318000–31FFFF SA107 1100100xxx 64/32 640000–64FFFF 320000–327FFF SA108 1100101xxx 64/32 650000–65FFFF 328000–32FFFF SA109 1100110xxx 64/32 660000–66FFFF 330000–337FFF SA110 1100111xxx 64/32 670000–67FFFF 338000–33FFFF SA111 1101000xxx 64/32 680000–68FFFF 340000–347FFF SA112 1101001xxx 64/32 690000–69FFFF 348000–34FFFF SA113 1101010xxx 64/32 6A0000–6AFFFF 350000–357FFF SA114 1101011xxx 64/32 6B0000–6BFFFF 358000–35FFFF SA115 1101100xxx 64/32 6C0000–6CFFFF 360000–367FFF SA116 1101101xxx 64/32 6D0000–6DFFFF 368000–36FFFF SA117 1101110xxx 64/32 6E0000–6EFFFF 370000–377FFF SA118 1101111xxx 64/32 6F0000–6FFFFF 378000–37FFFF SA119 1110000xxx 64/32 700000–70FFFF 380000–387FFF SA120 1110001xxx 64/32 710000–71FFFF 388000–38FFFF SA121 1110010xxx 64/32 720000–72FFFF 390000–397FFF SA122 1110011xxx 64/32 730000–73FFFF 398000–39FFFF SA123 1110100xxx 64/32 740000–74FFFF 3A0000–3A7FFF SA124 1110101xxx 64/32 750000–75FFFF 3A8000–3AFFFF SA125 1110110xxx 64/32 760000–76FFFF 3B0000–3B7FFF SA126 1110111xxx 64/32 770000–77FFFF 3B8000–3BFFFF SA127 1111000xxx 64/32 780000–78FFFF 3C0000–3C7FFF SA128 1111001xxx 64/32 790000–79FFFF 3C8000–3CFFFF SA129 1111010xxx 64/32 7A0000–7AFFFF 3D0000–3D7FFF SA130 1111011xxx 64/32 7B0000–7BFFFF 3D8000–3DFFFF SA131 1111100xxx 64/32 7C0000–7CFFFF 3E0000–3E7FFF SA132 1111101xxx 64/32 7D0000–7DFFFF 3E8000–3EFFFF SA133 1111110xxx 64/32 7E0000–7EFFFF 3F0000–3F7FFF SA134 1111111xxx 64/32 7F0000–7FFFFF 3F8000–3FFFFF Note: The address bus is A21:A-1 in byte mode where BYTE# = V IL or A20:A0 in word mode where BYTE# = V IH B B B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 11 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B PRODUCT SELECTOR GUIDE Product Number EN29LV640T/B -70 -90 Max Access Time, ns (t acc ) 70 90 Max CE# Access, ns (t ce ) 70 90 Max OE# Access, ns (t oe ) 30 35 Speed Option B B B B B B BLOCK DIAGRAM This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 12 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B TABLE 3. OPERATING MODES 64M FLASH USER MODE TABLE Operation Read Write CE# L L OE# L H WE# H L RESET # H H Accelerated Program L H L H WP#/AC C L/H (Note 1) A0A21 A IN A IN DQ0DQ7 D OUT D IN V HH A IN D IN B B B B B B B B B B DQ8-DQ15 BYTE# BYTE# = V IH = V IL D OUT DQ8DQ14= D IN High-Z, DQ15 = D IN A-1 B B B B B B B B B B B B B V cc 0.3V H L X X X V cc 0.3V H X High-Z High-Z High-Z X H X X H X H H L H L/H L/H High-Z High-Z High-Z High-Z High-Z High-Z High-Z High-Z High-Z Sector (Group) Protect L H L V ID (Note 2) X X Sector Unprotect L H L V ID X X X SA, A6=L, A1=H, A0=L SA, A6=H, A1=H, A0=L (Note 2) X X Temporary Sector Unprotect X X X V ID A IN (Note 2) (Note 2) High-Z B CMOS Standby TTL Standby Output Disable Hardware Reset B B B B B B L/H B (Note 1) B (Note 1) B B B L=logic low= V IL , H=Logic High= V IH , V ID =V HH =11 0.5V = 10.5-11.5V, X=Don’t Care (either L or H, but not floating ), SA=Sector Addresses, D IN =Data In, D OUT =Data Out, A IN =Address In B B B B B B B B B B B B B Notes: 1. If WP#/ACC = V IL , the two outermost boot sectors remain protected. If WP# / ACC = V IH , the outermost boot sector protection depends on whether they were last protected or unprotected. If WP#/ACC = V HH , all sectors will be unprotected. B B B B B B 2. Please refer to “Sector/Sector Group Protection & Chip Unprotection”, Flowchart 7a and Flowchart 7b. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 13 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B TABLE 4. Autoselect Codes (Using High Voltage, V ID ) B B 64M FLASH MANUFACTURER/DEVICE ID TABLE CE# OE# WE# A21 to A12 A11 to A10 A9 Manufacturer ID: Eon L L H X X V ID Device ID L Description 2 P P A8 H A6 A5 to A2 A1 A0 DQ8 to DQ15 X L X L L X 1 P B A7 B 1Ch P L Word L H (top boot sector) Byte L L H Device ID Word L L H (bottom boot sector) Byte L L H L L H X X V ID B B X 7Fh X L X L H X X V ID X X L X L H SA X V ID X X L X H L B B 22h B B C9h X C9h 22h CBh X CBh 01h X Sector Protection Verification DQ7 to DQ0 X (Protected) 00h (Unprotected) L=logic low= V IL , H=Logic High= V IH , V ID =11 0.5V, X=Don’t Care (either L or H, but not floating!), SA=Sector Addresses B B B B B B Note: 1. A8=H is recommended for Manufacturing ID check. If a manufacturing ID is read with A8=L, the chip will output a configuration code 7Fh. 2. A9 = V ID is for HV A9 Autoselect mode only. A9 must be ≤ Vcc (CMOS logic level) for Command Autoselect Mode. B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 14 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B USER MODE DEFINITIONS Word / Byte Configuration The signal set on the BYTE# pin controls whether the device data I/O pins DQ15-DQ0 operate in the byte or word configuration. When the BYTE# Pin is set at logic ‘1’, then the device is in word configuration, DQ15-DQ0 are active and are controlled by CE# and OE#. On the other hand, if the BYTE# Pin is set at logic ‘0’, then the device is in byte configuration, and only data I/O pins DQ0-DQ7 are active and controlled by CE# and OE#. The data I/O pins DQ8-DQ14 are tristated, and the DQ15 pin is used as an input for the LSB (A-1) address function. Standby Mode The EN29LV640T/B has a CMOS-compatible standby mode, which reduces the current to < 1µA (typical). It is placed in CMOS-compatible standby when the CE# pin is at V CC ± 0.5. RESET# and BYTE# pin must also be at CMOS input levels. The device also has a TTL-compatible standby mode, which reduces the maximum V CC current to < 1mA. It is placed in TTL-compatible standby when the CE# pin is at V IH . When in standby modes, the outputs are in a high-impedance state independent of the OE# input. B B B B B B B Automatic Sleep Mode The EN29LV640T/B has a automatic sleep mode, which minimizes power consumption. The devices will enter this mode automatically when the states of address bus remain stable for tacc + 30ns. ICC4 in the DC Characteristics table shows the current specification. With standard access times, the device will output new data when addresses change. Read Mode The device is automatically set to reading array data after device power-up or hardware reset. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm After the device accepts an Sector Erase Suspend command, the device enters the Sector Erase Suspend mode. The system can read array data using the standard read timings, except that if it reads at an address within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Sector Erase Suspend mode, the system may once again read array data with the same exception. See “Sector Erase Suspend/Resume Commands” for more additional information. The system must issue the reset command to re-enable the device for reading array data if DQ5 goes high or while in the autoselect mode. See the “Reset Command” for additional details. Output Disable Mode When the OE# pin is at a logic high level (V IH ), the output from the EN29LV640T/B is disabled. The output pins are placed in a high impedance state. B B Autoselect Identification Mode The autoselect mode provides manufacturer and device identification, and sector protection verification, through identifier codes output on DQ15–DQ0. This mode is primarily intended for programming equipment to automatically match a device to be programmed with its corresponding programming algorithm. However, the autoselect codes can also be accessed in-system through the command register. When using programming equipment, the autoselect mode requires V ID (10.5 V to 11.5 V) on address pin A9. Address pins A6, A1, and A0 must be as shown in Autoselect Codes table. In addition, when verifying B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. B 15 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B sector protection, the sector address must appear on the appropriate highest order address bits. Refer to the corresponding Sector Address Tables. The “Command Definitions” table shows the remaining address bits that are don’t-care. When all necessary bits have been set as required, the programming equipment may then read the corresponding identifier code on DQ15–DQ0. To access the autoselect codes in-system; the host system can issue the autoselect command via the command register, as shown in the Command Definitions table. This method does not require V ID . See “Command Definitions” for details on using the autoselect mode. B B Writing Command Sequences To write a command or command sequence to program data to the device or erase data, the system has to drive WE# and CE# to V IL, and OE# to V IH . B B B For program operations, the BYTE# pin determines whether the device accepts program data in bytes or words. An erase operation can erase one sector or the whole chip. The system can also read the autoselect codes by entering the autoselect mode, which need the autoselect command sequence to be written. Please refer to the “Command Definitions” for all the available commands. RESET#: Hardware Reset When RESET# is driven low for t RP , all output pins are tristates. All commands written in the internal state machine are reset to reading array data. B B Please refer to timing diagram for RESET# pin in “AC Characteristics”. Sector/Sector Group Protection & Chip Unprotection The hardware sector group protection feature disables both program and erase operations in any sector. The hardware chip unprotection feature re-enables both program and erase operations in previously protected sectors. A sector group implies three or four adjacent sectors that would be protected at the same time. Please see the following tables which show the organization of sector groups. There are two methods to enable this hardware protection circuitry. The first one requires only that the RESET# pin be at VID and then standard microprocessor timings can be used to enable or disable this feature. See Flowchart 7a and 7b for the algorithm and Figure. 12 for the timings. When doing Chip Unprotect, all the unprotected sector groups must be protected prior to any unprotect write cycle. The second method is for programming equipment. This method requires VID to be applied to both OE# and A9 pins and non-standard microprocessor timings are used. This method is described in a separate document named EN29LV640T/B Supplement, which can be obtained by contacting a representative of Eon Silicon Solution, Inc. U This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 16 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Top Boot Sector/Sector Group Organization Table (EN29LV640T) for (Un)Protection Sector Group Sectors A21-A12 Sector Group Size SG 0 SG 1 SG 2 SG 3 SG 4 SG 5 SG 6 SG 7 SG 8 SG 9 SG10 SG11 SG12 SG13 SG14 SG15 SG16 SG17 SG18 SG19 SG20 SG21 SG22 SG23 SG24 SG25 SG26 SG27 SG28 SG29 SG30 SA 0-SA 3 SA 4-SA 7 SA 8-SA 11 SA 12-SA 15 SA 16-SA 19 SA 20-SA 23 SA 24-SA 27 SA 28-SA 31 SA 32-SA 35 SA 36-SA 39 SA 40-SA 43 SA 44-SA 47 SA 48-SA 51 SA 52-SA 55 SA 56-SA 59 SA 60-SA 63 SA 64-SA 67 SA 68-SA 71 SA 72-SA 75 SA 76-SA 79 SA 80-SA 83 SA 84-SA 87 SA 88-SA 91 SA 92-SA 95 SA 96-SA 99 SA100-SA103 SA104-SA107 SA108-SA111 SA112-SA115 SA116-SA119 SA120-SA123 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 SG31 SA124-SA126 SG32 SG33 SG34 SG35 SG36 SG37 SG38 SG39 SA127 SA128 SA129 SA130 SA131 SA132 SA133 SA134 00000XXXXX 00001XXXXX 00010XXXXX 00011XXXXX 00100XXXXX 00101XXXXX 00110XXXXX 00111XXXXX 01000XXXXX 01001XXXXX 01010XXXXX 01011XXXXX 01100XXXXX 01101XXXXX 01110XXXXX 01111XXXXX 10000XXXXX 10001XXXXX 10010XXXXX 10011XXXXX 10100XXXXX 10101XXXXX 10110XXXXX 10111XXXXX 11000XXXXX 11001XXXXX 11010XXXXX 11011XXXXX 11100XXXXX 11101XXXXX 11110XXXXX 1111100XXX 1111101XXX 1111110XXX 1111111000 1111111001 1111111010 1111111011 1111111100 1111111101 1111111110 1111111111 64 Kbytes x 3 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes Bottom Boot Sector/Sector Group Organization Table (EN29LV640B) for (Un)Protection Sector Group Sectors A21-A12 Sector Group Size SG39 SG38 SG37 SG36 SG35 SG34 SG33 SG32 SG31 SG30 SG29 SA134-SA131 SA130-SA127 SA126-SA123 SA122-SA119 SA118-SA115 SA114-SA111 SA110-SA107 SA106-SA103 SA102-SA 99 SA 98-SA 95 SA 94-SA 91 11111XXXXX 11110XXXXX 11101XXXXX 11100XXXXX 11011XXXXX 11010XXXXX 11001XXXXX 11000XXXXX 10111XXXXX 10110XXXXX 10101XXXXX 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 17 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B SG28 SG27 SG26 SG25 SG24 SG23 SG22 SG21 SG20 SG19 SG18 SG17 SG16 SG15 SG14 SG13 SG12 SG11 SG10 SG 9 SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA SA 90-SA 86-SA 82-SA 78-SA 74-SA 70-SA 66-SA 62-SA 58-SA 54-SA 50-SA 46-SA 42-SA 38-SA 34-SA 30-SA 26-SA 22-SA 18-SA 14-SA 87 83 79 75 71 67 63 59 55 51 47 43 39 35 31 27 23 19 15 11 SG 8 SA 10-SA 8 SG SG SG SG SG SG SG SG SA SA SA SA SA SA SA SA 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 10100XXXXX 10011XXXXX 10010XXXXX 10001XXXXX 10000XXXXX 01111XXXXX 01110XXXXX 01101XXXXX 01100XXXXX 01011XXXXX 01010XXXXX 01001XXXXX 01000XXXXX 00111XXXXX 00110XXXXX 00101XXXXX 00100XXXXX 00011XXXXX 00010XXXXX 00001XXXXX 0000011XXX 0000010XXX 0000001XXX 0000000111 0000000110 0000000101 0000000100 0000000011 0000000010 0000000001 0000000000 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 3 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 4 64 Kbytes x 3 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes 8 Kbytes Write Protect / Accelerated Program (WP# / ACC) The WP#/ACC pin provides two functions. The Write Protect (WP#) function provides a hardware method of protecting the outermost two 8K-byte Boot Sector. The ACC function allows faster manufacturing throughput at the factory, using an external high voltage. When WP#/ACC is Low, the device protects the outermost tw 8K-byte Boot Sector; no matter the sectors are protected or unprotected using the method described in “Sector/Sector Group Protection & Chip Unprotection”, Program and Erase operations in these sectors are ignored. When WP#/ACC is High, the device reverts to the previous protection status of the outermost two 8K-byte boot sector. Program and Erase operations can now modify the data in the two outermost 8K-byte Boot Sector unless the sector is protected using Sector Protection. When WP#/ACC is raised to VHH the memory automatically enters the Unlock Bypass mode(please refer to “Command Definitions”), temporarily unprotects every protected sectors, and reduces the time required for program operation. The system would use a two-cycle program command sequence as required by the Unlock Bypass mode. When WP#/ACC returns to VIH or VIL, normal operation resumes. The transitions from VIH or VIL to VHH and from VHH to VIH or VIL must be slower than tBVHHB, see Figure 11. Note that the WP#/ACC pin must not be left floating or unconnected. In addition, WP#/ACC pin must not be at VHH for operations other than accelerated programming. It could cause the device to be damaged. Never raise this pin to VHH from any mode except Read mode, otherwise the memory may be left in an indeterminate state. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 18 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B A 0.1µF capacitor should be connected between the WP#/ACC pin and the VSS Ground pin to decouple the current surges from the power supply. The PCB track widths must be sufficient to carry the currents required during Unlock Bypass Program. Temporary Sector Unprotect Start This feature allows temporary unprotection of previously protected sector groups to change data while in-system. The Temporary Sector Unprotect mode is activated by setting the RESET# pin to VBIDB. During this mode, formerly protected sectors can be programmed or erased by simply selecting the sector addresses. Once VBIDB is removed from the RESET# pin, all the previously protected sectors are protected again. See accompanying flowchart and figure 10 for more timing details. Reset#=VID (note 1) B B B Perform Erase or Program Operations RESET#=VIH B B Temporary Sector Unprotect Completed (note 2) Notes: 1. All protected sectors are unprotected. (If WP#/ACC=VIL, outermost boot sectors will remain protected.) 2. Previously protected sectors are protected again. B B B B COMMON FLASH INTERFACE (CFI) The common flash interface (CFI) specification outlines device and host systems software interrogation handshake, which allows specific vendor-specified software algorithms to be used for entire families of devices. Software support can then be device-independent, JEDEC IDindependent, and forward- and backward-compatible for the specified flash device families. Flash vendors can standardize their existing interfaces for long-term compatibility. This device enters the CFI Query mode when the system writes the CFI Query command, 98h, to address 55h in word mode (or address AAh in byte mode), any time the device is ready to read array data. The system can read CFI information at the addresses given in Tables 5-8.In word mode, the upper address bits (A7–MSB) must be all zeros. To terminate reading CFI data, the system must write the reset command. The system can also write the CFI query command when the device is in the autoselect mode. The device enters the CFI query mode and the system can read CFI data at the addresses given in Tables 5–8. The system must write the reset command to return the device to the autoselect mode. Table 5. CFI Query Identification String Addresses (Word Mode) 10h 11h 12h 13h 14h 15h 16h 17h 18h 19h 1Ah Adresses (Byte Mode) 20h 22h 24h 26h 28h 2Ah 2Ch 2Eh 30h 32h 34h Data 0051h 0052h 0059h 0002h 0000h 0040h 0000h 0000h 0000h 0000h 0000h Description Query Unique ASCII string “QRY” Primary OEM Command Set Address for Primary Extended Table Alternate OEM Command set (00h = none exists) Address for Alternate OEM Extended Table (00h = none exists) This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 19 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Table 6. System Interface String Addresses (Word Mode) Addresses (Byte Mode) 1Bh 36h 1Ch 38h 1Dh 1Eh 1Fh 3Ah 3Ch 3Eh 20h 40h 21h 22h 23h 24h 25h 42h 44h 46h 48h 4Ah 26h 4Ch Data 0027h 0036h 0000h 0000h 0004h 0000h 000Ah 0000h 0005h 0000h 0004h 0000h Description Vcc Min (write/erase) DQ7-DQ4: volt, DQ3 –DQ0: 100 millivolt Vcc Max (write/erase) DQ7-DQ4: volt, DQ3 –DQ0: 100 millivolt Vpp Min. voltage (00h = no Vpp pin present) Vpp Max. voltage (00h = no Vpp pin present) Typical timeout per single byte/word write 2 N S Typical timeout for Min, size buffer write 2 N S (00h = not supported) Typical timeout per individual block erase 2 N ms Typical timeout for full chip erase 2 N ms (00h = not supported) Max. timeout for byte/word write 2 N times typical Max. timeout for buffer write 2 N times typical Max. timeout per individual block erase 2 N times typical Max timeout for full chip erase 2 N times typical (00h = not supported) P P P P P P P P P P P P P P P P Table 7. Device Geometry Definition Addresses (Word mode) 27h 28h 29h 2Ah 2Bh 2Ch 2Dh 2Eh 2Fh 30h 31h 32h 33h 34h 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch Addresses (Byte Mode) 4Eh 50h 52h 54h 56h 58h 5Ah 5Ch 5Eh 60h 62h 64h 66h 68h 6Ah 6Ch 6Eh 70h 72h 74h 76h 78h Data 0017h 0002h 0000h 0000h 0000h 0002h 0007h 0000h 0020h 0000h 007Eh 0000h 0000h 0001h 0000h 0000h 0000h 0000h 0000h 0000h 0000h 0000h Description Device Size = 2 N bytes P P Flash Device Interface description (refer to CFI publication 100) Max. number of byte in multi-byte write = 2 N (00h = not supported) Number of Erase Block Regions within device P P Erase Block Region 1 Information (refer to the CFI specification of CFI publication 100) Erase Block Region 2 Information Erase Block Region 3 Information Erase Block Region 4 Information This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 20 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Table 8. Primary Vendor-specific Extended Query Addresses (Word Mode) 40h 41h 42h 43h 44h Addresses (Byte Mode) 80h 82h 84h 86h 88h Data 0050h 0052h 0049h 0031h 0031h 45h 8Ah 0000h 46h 8Ch 0002h 47h 8Eh 0004h 48h 90h 0001h 49h 92h 0004h 4Ah 94h 0000h 4Bh 96h 0000h 4Ch 98h 0000h 4Dh 9Ah 00A5h 4Eh 9Ch 00B5h 4Fh 9Eh 0002h/ 0003h Description Query-unique ASCII string “PRI” Major version number, ASCII Minor version number, ASCII Address Sensitive Unlock 0 = Required, 1 = Not Required Erase Suspend 0 = Not Supported, 1 = To Read Only, 2 = To Read & Write Sector Protect 0 = Not Supported, X = Number of sectors in per group Sector Temporary Unprotect 00 = Not Supported, 01 = Supported Sector Protect/Unprotect scheme 01 = 29F040 mode, 02 = 29F016 mode, 03 = 29F400 mode, 04 = 29LV800A mode Simultaneous Operation 00 = Not Supported, 01 = Supported Burst Mode Type 00 = Not Supported, 01 = Supported Page Mode Type 00 = Not Supported, 01 = 4 Word Page, 02 = 8 Word Page Minimum ACC (Acceleration) Supply Voltage 00 = Not Supported, DQ7-DQ4 : Volts, DQ3-DQ0 : 100mV Maximum ACC (Acceleration) Supply Voltage 00 = Not Supported, DQ7-DQ4 : Volts, DQ3-DQ0 : 100mV Top/Bottom Boot Sector Identifier 02h = Bottom Boot, 03h = Top Boot This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 21 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Hardware Data protection The command sequence requirement of unlock cycles for programming or erasing provides data protection against inadvertent writes as seen in the Command Definitions table. Additionally, the following hardware data protection measures prevent accidental erasure or programming, which might otherwise be caused by false system level signals during Vcc power up and power down transitions, or from system noise. Low V CC Write Inhibit B B When Vcc is less than V LKO , the device does not accept any write cycles. This protects data during Vcc power up and power down. The command register and all internal program/erase circuits are disabled, and the device resets. Subsequent writes are ignored until Vcc is greater than V LKO . The system must provide the proper signals to the control pins to prevent unintentional writes when Vcc is greater than V LKO . B B B B B B Write Pulse “Glitch” protection Noise pulses of less than 5 ns (typical) on OE#, CE# or WE# do not initiate a write cycle. Logical Inhibit Write cycles are inhibited by holding any one of OE# = V IL , CE# = V IH , or WE# = V IH . To initiate a write cycle, CE# and WE# must be a logical zero while OE# is a logical one. If CE#, WE#, and OE# are all logical zero (not recommended usage), it will be considered a read. B B B B B B Power-up Write Inhibit During power-up, the device automatically resets to READ mode and locks out write cycles. Even with CE# = V IL , WE#= V IL and OE# = V IH , the device will not accept commands on the rising edge of WE#. B B B B B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 22 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B COMMAND DEFINITIONS The operations of the device are selected by one or more commands written into the command register. Commands are made up of data sequences written at specific addresses via the command register. The sequences for the specified operation are defined in the Command Definitions table (Table 9). Incorrect addresses, incorrect data values or improper sequences will reset the device to Read Mode. Command Sequence Cycles Table 9. EN29LV640T/B Command Definitions Bus Cycles 1 st Cycle Addr Data P P Read 1 RA RD Reset 1 xxx F0 Word Manufacturer ID 555 4 Autoselect Byte Device ID Top Boot Word Device ID Bottom Boot Word Sector Protect Verify Program Byte 4 AAA 555 2AA AA AA 555 2AA 90 555 55 55 AAA 555 Word 555 2AA 555 4 Byte Word Byte 4 AA 6 6 AAA A0 XXX 90 AAA 555 AAA AA AA Sector Erase Suspend 1 xxx B0 Sector Erase Resume 1 xxx 30 Word Byte 1 55 AA 55 555 PD XXX 00 555 2AA 555 555 th Cycle Addr Data P P 000 100 000 200 x01 7F 1C 7F 1C 22C9 x02 C9 x01 22CB x02 CB 90 (SA) X02 (SA) X04 A0 PA 5 th th Addr 2AA 555 P P P Cycle Data 00 01 00 01 PD 55 55 AAA 555 AAA 555 AAA 20 80 80 555 AAA 555 AAA AA AA 555 2AA 555 55 55 98 Address and Data values indicated are in hex. Unless specified, all bus cycles are write cycles RA = Read Address: address of the memory location to be read. This is a read cycle. RD = Read Data: data read from location RA during Read operation. This is a read cycle. PA = Program Address: address of the memory location to be programmed. X = Don’t-Care PD = Program Data: data to be programmed at location PA SA = Sector Address: address of the Sector to be erased or verified. Address bits A20-A12 uniquely select any Sector. Notes: 1. The data is 00H for an unprotected sector/sector block and 01H for a protected sector/sector block. 2. The data is 88H for factory locked and 08H for not factory locked. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 6 Cycle Addr Data P 555 55 PA 2AA 90 4 AAA 2AA AA XXX 555 2AA 90 AAA 555 555 3 2 Byte Word Byte 555 55 555 AAA 2 Word AA AAA P AAA AAA Unlock Bypass Reset CFI Query 55 555 Unlock Bypass Program Sector Erase 555 AAA Word Chip Erase 2AA P Byte Byte Unlock Bypass Cycle Addr Data P 555 555 3 rd Cycle Addr Data P AA AAA 4 2 nd 23 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 AAA SA 10 30 EN29LV640T/B Reading Array Data The device is automatically set to reading array data after power up. No commands are required to retrieve data. The device is also ready to read array data after completing an Embedded Program or Embedded Erase algorithm. Following a Sector Erase Suspend command, Sector Erase Suspend mode is entered. The system can read array data using the standard read timings from sectors other than the one which is being erase-suspended. If the system reads at an address within erase-suspended sectors, the device outputs status data. After completing a programming operation in the Sector Erase Suspend mode, the system may once again read array data with the same exception. The Reset command must be issued to re-enable the device for reading array data if DQ5 goes high during an active program or erase operation or while in the autoselect mode. See next section for details on Reset. Reset Command Writing the reset command to the device resets the device to reading array data. Address bits are don’t-care for this command. The reset command may be written between the cycle sequences in an erase command sequence before erasing begins. This resets the device to reading array data. Once erasure begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the sequence cycles in a program command sequence before programming begins. This resets the device to reading array data (also applies to programming in Sector Erase Suspend mode). Once programming begins, however, the device ignores reset commands until the operation is complete. The reset command may be written between the cycle sequences in an autoselect command sequence. Once in the autoselect mode, the reset command must be written to return to reading array data. If DQ5 goes high during a program or erase operation, writing the reset command returns the device to reading array data (also applies in Sector Erase Suspend mode). Autoselect Command Sequence The autoselect command sequence allows the host system to access the manufacturer and devices ID codes, and determine whether or not a sector (group) is protected. The Command Definitions table shows the address and data requirements. This is an alternative to the method that requires V ID on address bit A9 and is intended for commercial programmers. B B Two unlock cycles followed by the autoselect command initiate the autoselect command sequence. Autoselect mode is then entered and the system may read at addresses shown in Table 9 any number of times, without needing another command sequence. The system must write the reset command to exit the autoselect mode and return to reading array data. Word / Byte Programming Command The device can be programmed by byte or by word, depending on the state of the BYTE# Pin. Programming the EN29LV640T/B is performed by using a four-bus-cycle operation (two unlock write cycles followed by the Program Setup command and Program Data Write cycle). When the program command is executed, no additional CPU controls or timings are necessary. An internal timer This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 24 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B terminates the program operation automatically. Address is latched on the falling edge of CE# or WE#, whichever is last; data is latched on the rising edge of CE# or WE#, whichever is first. Any commands written to the device during the program operation are ignored. Programming status can be checked by sampling data on DQ7 (DATA# polling) or on DQ6 (toggle bit). When the program operation is successfully completed, the device returns to read mode and the user can read the data programmed to the device at that address. Note that data can not be programmed from a “0” to a “1”. Attempting to do so may halt the operation and set DQ5 to “1”, or cause the Data# Polling algorithm to indicate the operation was successful. However, a succeeding read will show that the data is still “0”. Only erase operations can convert a “0” to a “1”. When programming time limit is exceeded, DQ5 will produce a logical “1” and a Reset command can return the device to Read mode. Programming is allowed in any sequence across sector boundaries. Unlock Bypass To speed up programming operation, the Unlock Bypass Command may be used. Once this feature is activated, the shorter two-cycle Unlock Bypass Program command can be used instead of the normal four-cycle Program Command to program the device. During the unlock bypass mode, only the Unlock Bypass Program and Unlock Bypass Reset command can be accepted. This mode is exited after issuing the Unlock Bypass Reset Command. The device powers up with this feature disabled The device provides accelerated program operations through the WP#/ACC pin. When WP#/ACC is asserted to V HH , the device automatically enters the Unlock Bypass mode. The system may then write the two-cycle Unlock Bypass Program command sequence. B B Chip Erase Command Chip erase is a six-bus-cycle operation. The chip erase command sequence is initiated by writing two unlock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the chip erase command, which in turn invokes the Embedded Erase algorithm. The device does not require the system to preprogram prior to erase. The Embedded Erase algorithm automatically preprograms and verifies the entire memory for an all zero data pattern prior to electrical erase. The system is not required to provide any controls or timings during these operations. The Command Definitions table shows the address and data requirements for the chip erase command sequence. Any commands written to the chip during the Embedded Chip Erase algorithm are ignored. The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. See “Write Operation Status” for information on these status bits. When the Embedded Erase algorithm is complete, the device returns to reading array data and addresses are no longer latched. Sector Erase Command Sequence Sector erase is a six bus cycle operation. The sector erase command sequence is initiated by writing two un-lock cycles, followed by a set-up command. Two additional unlock write cycles are then followed by the address of the sector to be erased, and the sector erase command. The Command Definitions table shows the address and data requirements for the sector erase command sequence. Once the sector erase operation has begun, only the Sector Erase Suspend command is valid. All other commands are ignored. If there are several sectors to be erased, Sector Erase Command sequences must be issued for each sector. That is, only a sector address can be specified for each Sector Erase command. Users must issue another Sector Erase command for the next sector to be erased after the previous one is completed. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 25 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B When the Embedded Erase algorithm is completed, the device returns to reading array data and addresses are no longer latched. The system can determine the status of the erase operation by using DQ7, DQ6, or DQ2. Refer to “Write Operation Status” for information on these status bits. Flowchart 4 illustrates the algorithm for the erase operation. Refer to the Erase/Program Operations tables in the “AC Characteristics” section for parameters, and to the Sector Erase Operations Timing diagram for timing waveforms. Sector Erase Suspend / Resume Command The Sector Erase Suspend command allows the system to interrupt a sector erase operation and then read data from, or program data to, any sector not selected for erasure. This command is valid only during the sector erase operation. The Sector Erase Suspend command is ignored if written during the chip erase operation or Embedded Program algorithm. Addresses are don’t-cares when writing the Sector Erase Suspend command. When the Sector Erase Suspend command is written during a sector erase operation, the device requires a maximum of 20 µs to suspend the erase operation. After the erase operation has been suspended, the system can read array data from or program data to any sector not selected for erasure. Normal read and write timings and command definitions apply. Please note that Autoselect command sequence can not be accepted during Sector Erase Suspend. Reading at any address within erase-suspended sectors produces status data on DQ7–DQ0. The system can use DQ7, or DQ6 and DQ2 together, to determine if a sector is actively erasing or is erase-suspended. See “Write Operation Status” for information on these status bits. After an erase-suspended program operation is complete, the system can once again read array data within non-suspended sectors. The system can determine the status of the program operation using the DQ7 or DQ6 status bits, just as in the standard program operation. See “Write Operation Status” for more information. The Autoselect command is not supported during Sector Erase Suspend Mode. The system must write the Sector Erase Resume command (address bits are don’t-care) to exit the sector erase suspend mode and continue the sector erase operation. Further writes of the Resume command are ignored. Another Sector Erase Suspend command can be written after the device has resumed erasing. WRITE OPERATION STATUS DQ7: DATA# Polling The EN29LV640T/B provides DATA# polling on DQ7 to indicate the status of the embedded operations. The DATA# Polling feature is active during the Word/Byte Programming, Sector Erase, Chip Erase, and Sector Erase Suspend. (See Table 10) When the embedded programming is in progress, an attempt to read the device will produce the complement of the data written to DQ7. Upon the completion of the programming operation, an attempt to read the device will produce the true data written to DQ7. DATA# polling is valid after the rising edge of the fourth WE# or CE# pulse in the four-cycle sequence for program. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 26 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B When the embedded Erase is in progress, an attempt to read the device will produce a “0” at the DQ7 output. Upon the completion of the embedded Erase, the device will produce the “1” at the DQ7 output during the read cycles. For Chip Erase or Sector Erase, DATA# polling is valid after the rising edge of the last WE# or CE# pulse in the six-cycle sequence. DATA# Polling must be performed at any address within a sector that is being programmed or erased and not a protected sector. Otherwise, DATA# polling may give an inaccurate result if the address used is in a protected sector. Just prior to the completion of the embedded operations, DQ7 may change asynchronously when the output enable (OE#) is low. This means that the device is driving status information on DQ7 at one instant of time and valid data at the next instant of time. Depending on the time the system samples the DQ7 output, it may read the status of valid data. Even if the device has completed the embedded operation and DQ7 has a valid data, the data output on DQ0-DQ6 may be still invalid. The valid data on DQ0-DQ7 should be read on the subsequent read attempts. The flowchart for DATA# Polling (DQ7) is shown on Flowchart 5. The DATA# Polling (DQ7) timing diagram is shown in Figure 6. RY/BY#: Ready/Busy Status output The RY/BY# is a dedicated, open-drain output pin that indicates whether an Embedded Algorithm is in progress or completed. The RY/BY# status is valid after the rising edge of the final WE# pulse in the command sequence. Since RY/BY# is an open-drain output, several RY/BY# pins can be tied together in parallel with a pull-up resistor to Vcc. In the output-low period, signifying Busy, the device is actively erasing or programming. This includes programming in the Erase Suspend mode. If the output is high, signifying the Ready, the device is ready to read array data (including during the Erase Suspend mode), or is in the standby mode. DQ6: Toggle Bit I The EN29LV640T/B provides a “Toggle Bit” on DQ6 to indicate the status of the embedded programming and erase operations. (See Table 10) During an embedded Program or Erase operation, successive attempts to read data from the device at any address (by active OE# or CE#) will result in DQ6 toggling between “zero” and “one”. Once the embedded Program or Erase operation is completed, DQ6 will stop toggling and valid data will be read on the next successive attempts. During Programming, the Toggle Bit is valid after the rising edge of the fourth WE# pulse in the four-cycle sequence. During Erase operation, the Toggle Bit is valid after the rising edge of the sixth WE# pulse for sector erase or chip erase. In embedded programming, if the sector being written to is protected, DQ6 will toggles for about 2 μs, then stop toggling without the data in the sector having changed. In Sector Erase or Chip Erase, if all selected sectors are protected, DQ6 will toggle for about 100 μs. The chip will then return to the read mode without changing data in all protected sectors. The flowchart for the Toggle Bit (DQ6) is shown in Flowchart 6. The Toggle Bit timing diagram is shown in Figure 7. DQ5: Exceeded Timing Limits DQ5 indicates whether the program or erase time has exceeded a specified internal pulse count limit. Under these conditions DQ5 produces a “1.” This is a failure condition that indicates the program or erase cycle was not successfully completed. Since it is possible that DQ5 can become a 1 when the device has successfully completed its operation and has returned to read mode, the user must check again to see if the DQ6 is toggling after detecting a “1” on DQ5. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 27 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B The DQ5 failure condition may appear if the system tries to program a “1” to a location that is previously programmed to “0.” Only an erase operation can change a “0” back to a “1.” Under this condition, the device halts the operation, and when the operation has exceeded the timing limits, DQ5 produces a “1.” Under both these conditions, the system must issue the reset command to return the device to reading array data. DQ3: Sector Erase Timer After writing a sector erase command sequence, the output on DQ3 can be checked to determine whether or not an erase operation has begun. (The sector erase timer does not apply to the chip erase command.) When sector erase starts, DQ3 switches from “0” to “1”. This device does not support multiple sector erase (continuous sector erase) command sequences so it is not very meaningful since it immediately shows as a “1” after the first 30h command. Future devices may support this feature. DQ2: Erase Toggle Bit II The “Toggle Bit” on DQ2, when used with DQ6, indicates whether a particular sector is actively erasing (that is, the Embedded Erase algorithm is in progress), or whether that sector is erasesuspended. Toggle Bit II is valid after the rising edge of the final WE# pulse in the command sequence. DQ2 toggles when the system reads at addresses within those sectors that have been selected for erasure. (The system may use either OE# or CE# to control the read cycles.) But DQ2 cannot distinguish whether the sector is actively erasing or is erase-suspended. DQ6, by comparison, indicates whether the device is actively erasing, or is in Erase Suspend, but cannot distinguish which sectors are selected for erasure. Thus, both status bits are required for sector and mode information. Refer to the following table to compare outputs for DQ2 and DQ6. Flowchart 6 shows the toggle bit algorithm, and the section “DQ2: Toggle Bit” explains the algorithm. See also the “DQ6: Toggle Bit I” subsection. Refer to the Toggle Bit Timings figure for the toggle bit timing diagram. The DQ2 vs. DQ6 figure shows the differences between DQ2 and DQ6 in graphical form. Reading Toggle Bits DQ6/DQ2 Refer to Flowchart 6 for the following discussion. Whenever the system initially begins reading toggle bit status, it must read DQ7–DQ0 at least twice in a row to determine whether a toggle bit is toggling. Typically, a system would note and store the value of the toggle bit after the first read. After the second read, the system would compare the new value of the toggle bit with the first. If the toggle bit is not toggling, the device has completed the program or erase operation. The system can read array data on DQ7–DQ0 on the following read cycle. However, after the initial two read cycles, the system determines that the toggle bit is still toggling. And the system also should note whether the value of DQ5 is high (see the section on DQ5). If it is, the system should then determine again whether the toggle bit is toggling, since the toggle bit may have stopped toggling just as DQ5 went high. If the toggle bit is no longer toggling, the device has successfully completed the program or erase operation. If it is still toggling, the device did not complete the operation successfully, and the system must write the reset command to return to reading array data. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 28 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Write Operation Status Operation Standard Mode Erase Suspend Mode DQ7 DQ6 DQ5 DQ3 DQ2 RY/BY# Embedded Program Algorithm DQ7# Toggle 0 N/A No toggle 0 Embedded Erase Algorithm 0 Toggle 0 1 Toggle 0 1 No Toggle 0 N/A Toggle 1 Data Data Data Data Data 1 DQ7# Toggle 0 N/A N/A 0 Reading within Erase Suspended Sector Reading within Non-Erase Suspended Sector Erase-Suspend Program Table 10. Status Register Bits DQ Name Logic Level ‘1’ 7 DATA# POLLING ‘0’ DQ7 DQ7# ‘-1-0-1-0-1-0-1-’ 6 TOGGLE BIT DQ6 ‘-1-1-1-1-1-1-1-‘ 5 ERROR BIT 3 SECTOR ERASE TIME BIT 2 TOGGLE BIT Definition Erase Complete or erased sector in Sector Erase Suspend Erase On-Going Program Complete or data of non-erased sector during Sector Erase Suspend Program On-Going Erase or Program On-going Read during Sector Erase Suspend Erase Complete ‘1’ Program or Erase Error ‘0’ Program or Erase On-going ‘1’ Erase operation start ‘0’ Erase timeout period on-going ‘-1-0-1-0-1-0-1-’ DQ2 Chip Erase, Sector Erase or Read within EraseSuspended sector. (When DQ5=1, Erase Error due to currently addressed Sector or Program on Erase-Suspended sector Read on addresses of non Erase-Suspend sectors Notes: DQ7: DATA# Polling: indicates the P/E status check during Program or Erase, and on completion before checking bits DQ5 for Program or Erase Success. DQ6: Toggle Bit: remains at constant level when P/E operations are complete or erase suspend is acknowledged. Successive reads output complementary data on DQ6 while programming or Erase operation are on-going. DQ5: Error Bit: set to “1” if failure in programming or erase DQ3: Sector Erase Command Timeout Bit: Operation has started. Only possible command is Erase suspend (ES). DQ2: Toggle Bit: indicates the Erase status and allows identification of the erased Sector. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 29 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B EMBEDDED ALGORITHMS Flowchart 1. Embedded Program START Write Program Command Sequence (shown below) Data# Poll Device Verify Data? Increment Address Last No Address? Yes Programming Done Flowchart 2. Embedded Program Command Sequence (See the Command Definitions section for more information.) 555H / AAH 2AAH / 55H 555H / A0H PROGRAM ADDRESS / PROGRAM DATA This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 30 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Flowchart 3. Embedded Erase START Write Erase Command Sequence Data Poll from System or Toggle Bit successfully completed Data =FFh? No Yes Erase Done Flowchart 4. Embedded Erase Command Sequence (See the Command Definitions section for more information.) Chip Erase Sector Erase 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/80H 555H/80H 555H/AAH 555H/AAH 2AAH/55H 2AAH/55H 555H/10H Sector Address/30H This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 31 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Flowchart 5. DATA# Polling Algorithm Start Read Data DQ7 = Data? Yes No No DQ5 = 1? Yes Read Data (1) Notes: (1) This second read is necessary in case the first read was done at the exact instant when the status data was in transition. Yes DQ7 = Data? No Fail Pass Start Flowchart 6. Toggle Bit Algorithm Read Data twice No DQ6 = Toggle? Yes No DQ5 = 1? Yes Read Data twice (2) Notes: (2) This second set of reads is necessary in case the first set of reads was done at the exact instant when the status data was in transition. No DQ6 = Toggle? Yes Fail This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 32 Pass ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Flowchart 7a. In-System Sector (Group) Protect Flowchart START PLSCNT = 1 RESET# = VID Wait 1 μs No First Write Cycle = 60h? Temporary Chip Unprotect Mode Yes Set up sector (group) address To Protect: Write 60h to sector addr with A6 = 0, A1 = 1, A0 = 0 Wait 150 μs To Verify: Write 40h to sector(group) address with A6 = 0, A1 = 1, A0 = 0 Increment PLSCNT Reset PLSCNT = 1 Wait 0.4 μs Read from sector address with A6 = 0, A1 = 1, A0 No PLSCNT = 25? No Data = 01h? Yes Yes Device failed Protect another sector? Yes No Remove VID from RESET# Write reset command Sector Protect Algorithm This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Sector Protect complete 33 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Flowchart 7b. In-System Chip Unprotect Flowchart START PLSCNT = 1 Protect all sectors (groups): The indicated portion of the sector protect algorithm must be performed for all unprotected sectors prior to issuing the first sector unprotect address (see Diagram 7a.) RESET# = VID Wait 1 μS No Temporary Chip Unprotect Mode First Write Cycle = 60h? Yes No All sectors protected? Yes Set up first sector address Chip Unprotect: Write 60H to sector address with A6 = 1, A1 = 1, A0 = 0 Wait 15 ms Increment PLSCNT Verify Chip Unprotect: Write 40h to sector address with A6 = 1, A1 = 1, A0 =0 Wait 0.4 μS No PLSCCNT = 1000? Read from sector address with A6 = 1, A1 = 1, A0 = 0 No Yes Yes Device failed Set up next sector (group) address Data = 00h? Last sector verified? No Yes Chip Unprotect Algorithm Remove VID from RESET# This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 34 Write reset command Chip Unprotect complete ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B ABSOLUTE MAXIMUM RATINGS Parameter Value Unit Storage Temperature -65 to +125 C Plastic Packages -65 to +125 C -55 to +125 C 200 MA -0.5 to +11.5 V -0.5 to Vcc+0.5 V -0.5 to + 4.0 V Ambient Temperature With Power Applied Output Short Circuit Current 1 P P A9, OE#, RESET# and WP#/ACC 2 P Voltage with Respect to Ground All other pins P P P 3 P P Vcc Notes: 1. No more than one output shorted at a time. Duration of the short circuit should not be greater than one second. 2. Minimum DC input voltage on A9, OE#, RESET# and WP#/ACC pins is –0.5V. During voltage transitions, A9, OE#, RESET# and WP#/ACC pins may undershoot V ss to –1.0V for periods of up to 50ns and to –2.0V for periods of up to 20ns. See figure below. Maximum DC input voltage on A9, OE#, and RESET# is 11.5V which may overshoot to 12.5V for periods up to 20ns. 3. Minimum DC voltage on input or I/O pins is –0.5 V. During voltage transitions, inputs may undershoot V ss to –1.0V for periods of up to 50ns and to –2.0 V for periods of up to 20ns. See figure below. Maximum DC voltage on output and I/O pins is V cc + 0.5 V. During voltage transitions, outputs may overshoot to V cc + 1.5 V for periods up to 20ns. See figure below. 4. Stresses above the values so mentioned above may cause permanent damage to the device. These values are for a stress rating only and do not imply that the device should be operated at conditions up to or above these values. Exposure of the device to the maximum rating values for extended periods of time may adversely affect the device reliability. B B B B B B RECOMMENDED OPERATING RANGES 1 P Value Unit 0 to 70 -40 to 85 C Full Voltage Range: 2.7 to 3.6V V Ambient Operating Temperature Commercial Devices Industrial Devices 1. B P Parameter Operating Supply Voltage Vcc B Recommended Operating Ranges define those limits between which the functionality of the device is guaranteed. Vcc +1.5V Maximum Negative Overshoot Waveform This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. Maximum Positive Overshoot Waveform 35 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B DC Characteristics Table 11. DC Characteristics (T a = 0°C to 70°C or - 40°C to 85°C; V CC = 2.7-3.6V) B B B Symbol I LI B Parameter Test Conditions Input Leakage Current B B B Unit 0V≤ V IN ≤ Vcc ±5 µA 0V≤ V OUT ≤ Vcc ±5 µA (read) CMOS Word 9 16 mA 9 16 mA 20 30 mA 1 5.0 µA 1 5.0 mA 1 5.0 uA -0.5 0.7 x Vcc 0.8 Vcc ± 0.3 V 10.5 11.5 V 10.5 11.5 V 0.45 V B B B CE# = V IL , OE# = B I CC2 B Supply Current (Program or Erase) B I CC3 B I CC4 B Supply Current (Standby - CMOS) B B Reset Current B Automatic Sleep Mode B B B B V IL = Vss ± 0.3V Input High Voltage V IH B B #WP/ACC Voltage (Write Protect / Program Acceleration) Voltage for Autoselect or Temporary Sector Unprotect Output Low Voltage V HH B B V ID B B V OL B B Input Low Voltage B B Output High Voltage TTL I OL = 4.0 mA B B I OH = -2.0 mA B B V OH B B Output High Voltage CMOS V LKO B B B V IH = Vcc ± 0.3V B V IL B RESET# = Vss ± 0.3V B I CC5 B V IH , WE# = V IL CE# = BYTE# = RESET# = Vcc ± 0.3V (Note 1) B Typ B CE# = V IL ; OE# = V IH ; f = 5MHZ B B Min B B Supply Current (read) CMOS Byte I CC1 Max B Output Leakage Current I LO B B I OH = -100 A, B B Supply voltage (Erase and Program lock-out) 0.85 x Vcc Vcc 0.4V 2.3 V V V 2.5 V Notes: 1. BYTE# pin can also be GND ± 0.3V. BYTE# and RESET# pin input buffers are always enabled so that they draw power if not at full CMOS supply voltages. 2. Maximum I CC specifications are tested with Vcc = Vcc max. B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 36 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Test Conditions 3.3 V 2.7 kΩ Device under Test CL 6.2 kΩ Note: Diodes are IN3064 or equivalent Test Specifications Test Conditions -70 Output Load -90 Unit 1 TTL Gate Output Load Capacitance, C L 30 100 pF Input Rise and Fall times 5 5 ns Input Pulse Levels Input timing measurement reference levels Output timing measurement reference levels 0.0-3.0 0.0-3.0 V 1.5 1.5 V 1.5 1.5 V B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 37 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B AC CHARACTERISTICS Hardware Reset (RESET#) Parameter Std tREADY tREADY tRP tRH tRPD Description Reset# Pin Low to Read or Write Embedded Algorithms Reset# Pin Low to Read or Write Non Embedded Algorithms Reset# Pulse Width Reset# High Time Before Read Reset# to Standby Mode Test Setup Speed options -70 -90 Unit Max 20 s Max 500 nS Min Min Min 500 50 20 nS nS s Figure 1. AC Waveforms for RESET# Reset# Timings RY/BY# 0V CE# OE# tRH RESET# tRP tREADY Reset Timings NOT During Automatic Algorithms RY/BY# tREADY CE# OE# RESET# tRP tRH Reset Timings During Automatic Algorithms This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 38 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B AC CHARACTERISTICS Word / Byte Configuration (BYTE#) Std Parameter t BCS t CBH t RBH B B B B B B Speed Description BYTE# to CE# switching setup time CE# to BYTE# switching hold time RY/BY# to BYTE# switching hold time Min Min Min -70 0 0 0 -90 0 0 0 Figure 2. AC Waveforms for BYTE# CE# OE# Byte# tCBH tBCS Byte# timings for Read Operations CE# WE# Byte# tRBH tBCS RY/BY# Byte #timings for Write Operations Note: Switching BYTE# pin not allowed during embedded operations This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 39 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 Unit ns ns ns EN29LV640T/B AC CHARACTERISTICS Table 12. Read-only Operations Characteristics Parameter Symbols Speed Options Test Setup JEDEC Standard Description t AVAV t RC Read Cycle Time -70 -90 Unit Min 70 90 ns CE# = V IL OE# = V IL Max 70 90 ns OE# = V IL Max 70 90 ns Output Enable to Output Delay Max 30 35 ns t DF Chip Enable to Output High Z Max 20 20 ns t GHQZ t DF Output Enable to Output High Z Max 20 20 ns t AXQX t OH Output Hold Time from Addresses, CE# or OE#, whichever occurs first Min 0 0 ns Read Min 0 0 ns Toggle and Data# Polling Min 10 10 ns B B B B B t AVQV B t ACC B B Address to Output Delay B B B t ELQV B t GLQV B t CE B B t OE B B t EHQZ B B B B B B B B B Chip Enable To Output Delay B B B B B Output Enable Hold Time t OEH B Notes: For - 70 - 90 B B B B B B B B B Vcc = 3.0V – 3.6V Output Load: 1 TTL gate and 30pF Input Rise and Fall Times: 5ns Input Pulse Levels: 0.0 V to 3.0 V Timing Measurement Reference Level, Input and Output: 1.5 V Vcc = 2.7V – 3.6V Output Load: 1 TTL gate and 100 pF Input Rise and Fall Times: 5 ns Input Pulse Levels: 0.0 V to 3.0 V Timing Measurement Reference Level, Input and Output: 1.5 V Figure 3. AC Waveforms for READ Operations tRC B B Addresses Stable Addresses tACC B CE# tDF B tOE B OE# B tOEH B WE# B tCE B tOH B B Output Valid Outputs HIGH Z RESET# RY/BY# 0V This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 40 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B AC CHARACTERISTICS Table 13. Write (Erase/Program) Operations Parameter Symbols Speed Options JEDEC Standard t AVAV t WC B B t WLAX B 90 ns Address Setup Time Min 0 0 ns t AH Address Hold Time Min 45 40 ns t DS Data Setup Time Min 30 40 ns B Data Hold Time Min 0 0 ns Output Enable Setup Time Min 0 0 ns Min 10 20 ns Min 0 0 ns CE# Setup Time Min 0 0 ns CE# Hold Time Min 0 0 ns Write Pulse Width Min 45 30 ns Write Pulse Width High Min 20 25 ns Byte Typ 8 8 Word Typ 8 8 Accelerated Programming Operation (Word AND Byte Mode) Typ 7 5 µs Sector Erase Operation Typ 0.5 0.5 s Chip Erase Operation Typ 70 64 s tVHH VHH Rise and Fall Time Min 250 250 ns t VCS Vcc Setup Time Min 50 50 µs B t AS B B t WHDX B B B B B B t DH B B B t OES B B Output Enable Hold Time during Toggle and DATA# Polling Read Recovery Time before Write (OE# High to WE# Low) t OEH B t GHWL B t ELWL B B B B B t CH B B B t WLWH t WP t WHDL t WPH B B B B B t WHW1 B t WHW1 B t WHW2 B t WHW3 B B t CS t WHEH B B t GHWL B B B B B B B Unit 70 B B -90 Min B t DVWH -70 Write Cycle Time B t AVWL Description B t WHWH1 B t WHWH1 B t WHWH2 B t WHWH3 B B B B B B B Programming Operation µs This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 41 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B AC CHARACTERISTICS Table 14. Write (Erase/Program) Operations Alternate CE# Controlled Writes Parameter Symbols Speed Options JEDEC Standard t AVAV t WC t AVEL t AS t ELAX Description -70 -90 Unit Write Cycle Time Min 70 90 ns Address Setup Time Min 0 0 ns t AH Address Hold Time Min 45 40 ns t DVEH t DS Data Setup Time Min 30 40 ns t EHDX t DH Data Hold Time Min 0 0 ns Output Enable Setup Time Min 0 0 ns Read Recovery Time before Write (OE# High to CE# Low) Min 0 0 ns WE# Setup Time Min 0 0 ns WE# Hold Time Min 0 0 ns CE# Pulse Width Min 35 45 ns CE# Pulse Width High Min 20 20 ns Byte Typ 8 8 Word Typ 8 8 Accelerated Programming Operation (Word AND Byte Mode) Typ 7 5 µs Sector Erase Operation Typ 0.5 0.5 s B B B B B B B B B B B B B B B B B B B B t OES B t GHEL B B t GHEL B t WLEL B t WS B t EHWH B B B B t WH B B B t ELEH t CP t EHEL t CPH B B B B t WHW1 B t WHW1 B t WHW2 B B B B B B B B B t WHWH1 B t WHWH1 B t WHWH2 B B B B Programming Operation This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. µs 42 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B AC CHARACTERISTICS Figure 4. AC Waveforms for Chip/Sector Erase Operations Timings Erase Command Sequence (last 2 cycles) Addresses tWC tAS 0x2AA SA Read Status Data (last two cycles) tAH VA VA 0x555 for chip erase CE# tGHW L OE# tCH tWP WE# tWPH tCS tWHWH2 or tWHWH3 Data 0x55 0x30 tDS tDH Status DOUT tBUSY tRB RY/BY# VCC tVCS Notes: 1. SA=Sector Address (for sector erase), VA=Valid Address for reading status, D out =true data at read address. 2. V cc shown only to illustrate t vcs measurement references. It cannot occur as shown during a valid command sequence. B B B B B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 43 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Figure 5. Program Operation Timings Program Command Sequence (last 2 cycles) Addresses tWC tAS 0x555 PA Program Command Sequence (last 2 cycles) tAH PA PA CE# tGHWL OE# tWP WE# tCH tWPH tWHWH1 tCS Data PD OxA0 Status tDS tRB tBUSY tDH DOUT RY/BY# tVCS VCC Notes: 1. PA=Program Address, PD=Program Data, D OUT is the true data at the program address. 2. V CC shown in order to illustrate t VCS measurement references. It cannot occur as shown during a valid command sequence. B B B B B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 44 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Figure 6. AC Waveforms for /DATA Polling During Embedded Algorithm Operations tRC Addresses VA VA VA tACC tCH tCE CE# tOE OE# tOEH tDF WE# tOH Complement Complement DQ[7] DQ[6:0] Status Data Status Data True Valid Data True Valid Data tBUS RY/BY# Notes: 1. VA=Valid Address for reading Data# Polling status data 2. This diagram shows the first status cycle after the command sequence, the last status read cycle and the array data read cycle. Figure 7. AC Waveforms for Toggle Bit During Embedded Algorithm Operations tRC Addresses VA VA VA VA tACC tCH tCE CE# tOE OE# tOEH WE# tDF tOH Valid Status DQ6, DQ2 tBUSY (first read) Valid Status (second d) Valid Status Valid Data (stops toggling) RY/BY# This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 45 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Figure 8. Alternate CE# Controlled Write Operation Timings PA for Program SA for Sector Erase 0x555 for Chip Erase 0x555 for Program 0x2AA for Erase Addresses VA tAS tWC tAH WE# tWH tGHEL OE# tCP tCPH tWS tCWHWH1 / tCWHWH2 / tCWHWH3 CE# tDS tBUSY tDH Status Data DOUT PD for Program 0x30 for Sector Erase 0x10 for Chip Erase 0xA0 for Program RY/BY# tRH Reset# Notes: PA = address of the memory location to be programmed. PD = data to be programmed at byte address. VA = Valid Address for reading program or erase status D out = array data read at VA Shown above are the last two cycles of the program or erase command sequence and the last status read cycle RESETt# shown to illustrate t RH measurement references. It cannot occur as shown during a valid command sequence. B B B B Figure 9. DQ2 vs. DQ6 Enter Embedded Erase WE# Enter Erase Suspend Program Erase Suspend Erase Erase Resume Enter Suspend Program Enter Suspend Read Erase Suspend Read Erase DQ6 DQ2 This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 46 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 Erase Complete EN29LV640T/B AC CHARACTERISTICS Temporary Sector Unprotect Parameter Std Description t VIDR V ID Rise and Fall Time V HH Rise and Fall Time RESET# Setup Time for Temporary Sector Unprotect B t VIHH B B B t RSP B B B B B B Speed Option -70 -90 Unit Min 500 Ns Min 500 Ns Min 4 µs Figure 10. Temporary Sector Unprotect Timing Diagram VID RESET# 0 or 3 V 0 or 3 V tVIDR tVIDR CE# WE# tRSP RY/BY# AC CHARACTERISTICS Write Protect / Accelerated Program Figure 11. Accelerated Program Timing Diagram VHH B B WP#/ACC 0 or 3 V 0 or 3 V tVHH B tVHH B B B CE# WE# tRSP B B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 47 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B AC CHARACTERISTICS Sector (Group) Protect and Chip Unprotect Figure 12. Sector (Group) Protect and Chip Unprotect Timing Diagram VID Vcc RESET# 0V 0V tVIDR tVIDR SA, A6,A1,A0 Data 60h Valid Valid Valid 60h 40h Status Sector Protect/Unprotect Verify CE# >0.4μS WE# >1μS Protect: 150 uS Unprotect: 15 mS OE# Notes: Use standard microprocessor timings for this device for read and write cycles. For Sector (Group) Protect, use A6=0, A1=1, A0=0. For Chip Unprotect, use A6=1, A1=1, A0=0. This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 48 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B ERASE AND PROGRAM PERFORMANCE Parameter Limits Max Typ Sector Erase Time 0.5 Chip Erase Time 64 Accelerated Word Program Time 5 120 µS Word Programming Time 8 300 µS Chip Programming Time 20 60 Sec Erase/Program Endurance Comments Unit 10 Sec Sec 100K Excludes 00h programming prior to erasure Minimum 100K cycles Cycles Note: Typical Conditions are room temperature, 3V and checkboard pattern programmed. LATCH UP CHARACTERISTICS Parameter Description Min Max Input voltage with respect to V ss on all pins except I/O pins (including A9, Reset and OE#) -1.0 V 12.0 V Input voltage with respect to V ss on all I/O Pins -1.0 V Vcc + 1.0 V Vcc Current -100 mA 100 mA B B B B Note: These are latch up characteristics and the device should never be put under these conditions. Refer to Absolute Maximum ratings for the actual operating limits. 48-PIN TSOP PACKAGE CAPACITANCE Parameter Symbol Parameter Description Test Setup Typ Max Unit Input Capacitance V IN = 0 6 7.5 pF C OUT Output Capacitance V OUT = 0 8.5 12 pF C IN2 Control Pin Capacitance V IN = 0 7.5 9 pF C IN B B B B B B B B B B B B Note: Test conditions are Temperature = 25°C and f = 1.0 MHz. DATA RETENTION Parameter Description Test Conditions Min Unit 150°C 10 Years 125°C 20 Years Minimum Pattern Data Retention Time This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 49 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B FIGURE 13. TSOP 12mm x 20mm This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 50 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 51 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B FIGURE 14. 48TFBGA package outline This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 52 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16 EN29LV640T/B Revisions List Revision No Description A Initial Release 2007/3/13 1. Move the feature of SECURED SILICON SECTOR 2. Change the notes for 70 ns products from Vcc = 2.7V – 3.6V 2007/05/16 to Vcc = 3.0V – 3.6V at Table 12. Read-only Operations Characteristics in page 40 B Date This Data Sheet may be revised by subsequent versions or modifications due to changes in technical specifications. 53 ©2004 Eon Silicon Solution, Inc., www.essi.com.tw Rev. B, Issue Date: 2007/05/16