INFINEON ESD5V0H1U-02LS

ESD5V0H1U-02LS
Ultra-Low Capacitance TVS Diode
• Avalanche diode with low clamping / trigger
voltage designed for replacement of polymer
suppressor devices
• ESD / transient protection of high-speed
data lines exceeding
IEC61000-4-2 (ESD): 16 kV (contact)
IEC61000-4-4 (EFT): 2.5 kV / 50 A (5/50 ns)
• No degradation or shifting of characteristics even
after 1000 ESD pulses and lower peak voltage
than polymer devices
(see curve on page 4)
• Very low capacitance: 0.2 pF typ. @ 1.8 GHz
• Smallest form factor: 0.6 x 0.3 x 0.3 mm
• Working voltage: 5 V (can be extended to 60 V)
• Response time typ. < 0.5 ns @ 8 kV
• Pb-free (RoHS) compliant) package
• Qualified according AEC Q101
Applications
• 10/100/1000 Ethernet
• HDMI & DVI Interfaces
• Mobile communication and LCD displays
• Consumer products ( STB, MP3, DVD, DSC...)
• Notebooks and desktop computers, peripherals
ESD5V0H1U-02LS
1
2
Type
ESD5V0H1U-02LS
Package
TSSLP-2-1
Configuration
1 line, uni-directional
1
Marking
P
2009-06-18
ESD5V0H1U-02LS
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter
Symbol
ESD contact discharge1)
VESD
Operating temperature range
Storage temperature
Value
Unit
16
kV
T op
-55...125
°C
T stg
-65...150
Electrical Characteristics at TA = 25°C, unless otherwise specified
Parameter
Symbol
Values
Unit
min.
typ.
max.
Characteristics
Reverse working voltage
VRWM
-
-
5
V
Avalanche breakdown voltage
V(BR)
-
200
-
IR
-
-
0.1
µA
VCL
-
40
-
V
I(BR) = 1 mA, from pin 2 to 1
Reverse current
VR = 5 V
Clamping voltage1) after 30 ns
VESD = 8 kV, contact, from pin 2 to 1
Line capacitance2)
pF
CT
VR = 0 V, f = 1.8 GHz
-
0.2
0.4
VR = 0 V, f = 1 MHz
-
0.27
0.42
-
0.2
-
Series inductance
LS
nH
1V
ESD according to IEC61000-4-2
2Total
capacitance line to ground
2
2009-06-18
ESD5V0H1U-02LS
Reverse current IR = ƒ (TA)
Diode capacitance CT = ƒ (VR)
f = 1GHz
VR = 5 V
10 -6
VR
0.4
10 -7
pF
Ct
IR
10
-8
10 -9
0.2
10
-10
10 -11
0.1
10 -12
10 -13
0
25
50
75
100
°C
0
0
150
TA
5
10
15
20
25
30
V
40
VR
Line capacitance CT = ƒ (f)
VR = 0 V
0.4
Ct
pF
0.2
0.1
0
0
500
1000
1500
2000
MHz
3000
f
3
2009-06-18
ESD5V0H1U-02LS
Application example
single channel, uni-directional
Connector
Protected signal line
I/O
1
2
The protection diode
should be placed very
close to the location
where the ESD can
occur to keep loops and
inductances as small as
possible.
4
ESD
sensitive
device
2009-06-18
ESD5V0H1U-02LS
Clamping voltage at real ESD event according to IEC61000-4-2, 8 kV
contact discharge: comparison with polymer suppressor.
ESD gun: C=150pF/R=330Ω... with 6 GHz oscilloscope (50 Ω)
5
2009-06-18
Package TSSLP-2-1
6
ESD5V0H1U-02LS
2009-06-18
ESD5V0H1U-02LS
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office ( www.infineon.com ).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.
7
2009-06-18