INFINEON BAR66

BAR66...
Silicon PIN Diode Array
• Surge protection device
• Designed for surge overvoltage clamping
in antiparallel connection
• Pb-free (RoHS compliant) package 1)
• Qualified according AEC Q101
BAR66
!
, ,
Type
BAR66
Package
SOT23
Configuration
series
LS(nH)
1.8
Marking
PMs
Maximum Ratings at TA = 25°C, unless otherwise specified
Parameter
Symbol
Value
Unit
Diode reverse voltage
VR
150
V
Forward current
IF
200
mA
Total power dissipation
Ptot
250
mW
ESD contact discharge2)
VESD
25
kV
Peak pulse current (tp = 8 / 20 µs)3)
I pp
12
A
Junction temperature
Tj
150
°C
Operating temperature range
T op
-55 ... 125
Storage temperature
T stg
-55 ... 150
Ts ≤ 25 °C
Thermal Resistance
Parameter
Symbol
Value
Unit
Junction - soldering point 4), BAR 66
RthJS
≤ 290
K/W
1Pb-containing
package may be available upon special request
according
to IEC61000-4-2, only valid if pin 1 and pin 2 are connected
ESD
2V
3I
pp according to IEC61000-4-5, only valid if pin 1 and pin 2 are connected
calculation of RthJA please refer to Application Note Thermal Resistance
4For
1
2007-04-19
BAR66...
Electrical Characteristics at TA = 25°C, unless otherwise specified
Parameter
Symbol
Values
Unit
min.
typ.
max.
150
-
-
V
IR
-
-
20
nA
VF
-
0.95
1.2
V
VESD = ± 15 kV (contact) 1)
-
tbd
-
IPP = 12 A, tp = 8/20 µs2)
-
7
-
DC Characteristics
Breakdown voltage
V(BR)
I(BR) = 5 µA
Reverse current
VR = 100 V
Forward voltage
IF = 50 mA
Clamping voltage
VCL
AC Characteristics
Diode capacitance
pF
CT
VR = 35 V, f = 1 MHz
-
0.4
0.6
VR = 0 V, f = 100 MHz
-
0.35
0.9
gP
-
220
-
µS
rf
-
1.5
1.8
Ω
τ rr
-
0.7
-
µs
Zero bias conductance
VR = 0 V, f = 1 GHz
Forward resistance
I F = 5 mA, f = 100 MHz
Charge carrier life time
I F = 10 mA, IR = 6 mA, measured at IR = 3 mA,
RL = 100 Ω
1V
ESD according to IEC61000-4-2, only valid if pin 1 and pin 2 are connected
pp according to IEC61000-4-5, only valid if pin 1 and pin 2 are connected
2I
2
2007-04-19
BAR66...
Diode capacitance CT = ƒ (VR)
f = Parameter
Forward resistance rf = ƒ (I F)
f = 100MHz
10 3
0.8
Ohm
pF
10 2
0.5
rf
CT
0.6
0.3
10 1
1MHz
0.4
100MHz
10 0
0.2
0.1
0
0
5
10
15
20
25
V
10 -1 -2
10
35
10
-1
10
0
10
VR
1
mA 10 2
IF
Forward current IF = ƒ (VF)
Forward current IF = ƒ (T S)
TA = Parameter
BAR66
10 0
A
220
mA
10 -1
180
160
IF
IF
10 -2
140
120
10 -3
100
-40 °C
25 °C
85 °C
125 °C
10 -4
80
60
10 -5
40
20
10 -6
0
0.2
0.4
0.6
0.8
V
0
0
1.2
VF
20
40
60
80
100
120 °C
150
TS
3
2007-04-19
BAR66...
Permissible Puls Load RthJS = ƒ (tp)
Permissible Pulse Load
BAR66
IFmax / I FDC = ƒ (t p)
BAR66
10
3
10 2
I Fmax/IFDC
K/W
R thJS
10 2
10 1
D=0
0.005
0.01
0.02
0.05
0.1
0.2
0.5
10 1
0.5
0.2
0.1
0.05
0.02
0.01
0.005
D=0
10 0
10 -1 -6
10
-
10
-5
10
-4
10
-3
10
-2
s
10
10 0 -6
10
0
tP
10
-5
10
-4
10
-3
10
-2
s
10
0
tP
4
2007-04-19
Package SOT23
BAR66...
0.4 +0.1
-0.05
1)
2
0.08...0.1
C
0.95
1.3 ±0.1
1
2.4 ±0.15
3
0.1 MAX.
10˚ MAX.
B
1 ±0.1
10˚ MAX.
2.9 ±0.1
0.15 MIN.
Package Outline
A
5
0...8˚
1.9
0.2
0.25 M B C
M
A
1) Lead width can be 0.6 max. in dambar area
Foot Print
0.8
0.9
1.3
0.9
0.8
1.2
Marking Layout (Example)
Manufacturer
EH s
2005, June
Date code (YM)
Pin 1
BCW66
Type code
Standard Packing
Reel ø180 mm = 3.000 Pieces/Reel
Reel ø330 mm = 10.000 Pieces/Reel
4
0.2
8
2.13
2.65
0.9
Pin 1
1.15
3.15
5
2007-04-19
BAR66...
Edition 2006-02-01
Published by
Infineon Technologies AG
81726 München, Germany
© Infineon Technologies AG 2007.
All Rights Reserved.
Attention please!
The information given in this dokument shall in no event be regarded as a guarantee
of conditions or characteristics (“Beschaffenheitsgarantie”). With respect to any
examples or hints given herein, any typical values stated herein and/or any information
regarding the application of the device, Infineon Technologies hereby disclaims any
and all warranties and liabilities of any kind, including without limitation warranties of
non-infringement of intellectual property rights of any third party.
Information
For further information on technology, delivery terms and conditions and prices
please contact your nearest Infineon Technologies Office ( www.infineon.com).
Warnings
Due to technical requirements components may contain dangerous substances.
For information on the types in question please contact your nearest
Infineon Technologies Office.
Infineon Technologies Components may only be used in life-support devices or
systems with the express written approval of Infineon Technologies, if a failure of
such components can reasonably be expected to cause the failure of that
life-support device or system, or to affect the safety or effectiveness of that
device or system.
Life support devices or systems are intended to be implanted in the human body,
or to support and/or maintain and sustain and/or protect human life. If they fail,
it is reasonable to assume that the health of the user or other persons
may be endangered.
6