EMERSON-NETWORKPOWER EXB250

EXB250 Series
Single output
DC-DC CONVERTERS
72-165 W High Efficiency DC-DC Converters
1
• High efficiency topology, 90% typical at 3.3 V
• Industry standard footprint
• Wide baseplate temperature, -40 ˚C to +100 ˚C
(natural convection)
• 90% to 110% output trim
• No minimum load
• Overvoltage protection
• Remote ON/OFF
• Available RoHS compliant
The EXB250 is a new high efficiency, open-frame, isolated 165 Watt converter series in an
industry standard half-brick footprint. The EXB250 delivers very high output current at low
voltages, and excellent useable power density for today’s high end applications. The design takes
advantage of open frame construction to provide a low weight, low thermal impedance baseplate
design. The seven models in the series feature an input voltage range of 33 Vdc to 75 Vdc and
are available in output voltages of 12 V, 5 V, 3.3 V, 2.5 V, 1.8 V, 1.5 V and 1.2 V. The output voltage
on each model is adjustable from 90% to 110% of the nominal value. Typical efficiencies for the
models are 90% for the 3.3 V, 88% for the 2.5 V and 87% for the 1.8 V version. The EXB250
series also has a remote ON/OFF capability. Overcurrent and overvoltage protection features are
included as standard. With full international safety approval including EN60950 (TÜV Rheinland)
and UL/cUL1950, the EXB250 reduces compliance costs and time to market.
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
OUTPUT SPECIFICATIONS
EMC CHARACTERISTICS
Voltage adjustability
90% to 110%
Set point accuracy
±1.6% max.
Line regulation
Low line to high line
1.2 V model
All other models
±0.2% max.
±0.1% max.
Load regulation
Full load to min. load
±0.2% max.
Minimum load
0%
Conducted emissions
EN55022 (See Note 2)
EN55022 (See Note 2)
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
EN61000-4-2
8 kV (NP), 15 kV
EN61000-4-2
6 kV (NP), 8 kV
EN61000-4-3
10 V/m
EN61000-4-6
10 V
EN61000-4-6
10 V
ETS 300 132-2, ETR 283
Overshoot
At turn-on and turn-off
None
GENERAL SPECIFICATIONS
Undershoot
1.2 V, 1.5 V (Z), 1.8 V (Z),
2.5 V (Z) and 3.3 V (Z) models
None
Efficiency
Ripple and noise
5 Hz to 20 MHz
Transient response
(See Note 1)
60 mV pk-pk
20 mV rms
6% max. deviation
150 µs recovery to
within total error band
Input/output
Input/baseplate
Switching frequency
Fixed
Input voltage range
48 Vin nominal
Weight
Input current
No load
Remote OFF
Input current (max.)
(See Note 3)
Input reflected ripple
33-75 Vdc
145 mA max.
35 mA max.
MTBF
5.7 A max. @ Io max.
and Vin = 33-75 Vdc
(See Note 5)
Active high remote ON/OFF
Logic compatibility
ON
OFF
350 mA (pk-pk) typ.
Undervoltage lockout
Power up
Power down
32.5 V (typ.)
30.5 V (typ.)
Start-up time
(See Note 6)
Power up
Remote ON/OFF
10 ms (typ.)
3 ms (typ.)
EN60950 (TÜV Rheinland)
UL/cUL1950
UL94V-0
73 g (2.6 oz)
Telcordia SR-332
@ 25 °C, 100% load
ground benign
Demonstrated
1,598,243 hours
>2,000,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Open collector ref to -input
Open circuit or >4.0 Vdc
<1.2 Vdc
1500 Vdc
1500 Vdc
400 kHz typ.
Approvals and
standards (See Note 4)
Material flammability
(NP)
(NP)
(NP)
(NP)
(NP)
See table
Operational
INPUT SPECIFICATIONS
Level A
Level B
Operating baseplate -40 °C to +100 °C
temperature
Non-operating
-40 °C to +125 °C
File Name: exb250s.pdf Rev (02): 06 Dec 2005
EXB250 Series
Single output
DC-DC CONVERTERS
72-165 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
OUTPUT
POWER
(MAX.)
INPUT
VOLTAGE
OVP
OUTPUT
VOLTAGE
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
EFFICIENCY
(TYP.)
LINE
LOAD
MODEL
NUMBER (8,9)
72 W
33-75 Vdc
1.44 Vdc
1.2 V
0A
60 A
84.0%
±0.2%
±0.2%
EXB250-48S1V2J
90 W
33-75 Vdc
1.8 Vdc
1.5 V
0A
60 A
85.5%
±0.1%
±0.2%
EXB250-48S1V5J
108 W
33-75 Vdc
2.2 Vdc
1.8 V
0A
60 A
87.0%
±0.1%
±0.2%
EXB250-48S1V8J
150 W
33-75 Vdc
3 Vdc
2.5 V
0A
60 A
88.0%
±0.1%
±0.2%
EXB250-48S2V5J
165 W
33-75 Vdc
4 Vdc
3.3 V
0A
50 A
90.0%
±0.1%
±0.2%
EXB250-48S3V3J
165 W
33-75 Vdc
6 Vdc
5V
0A
33 A
91.7%
±0.1%
±0.2%
EXB250-48S05J
165 W
33-75 Vdc
14.4 Vdc
12 V
0A
13.75 A
92.0%
±0.1%
±0.2%
EXB250-48S12J
Part Number System with Options
EXB250-48S1V2-ZRNJ
RoHS Compliance (8,9)
J = Pb-free (RoHS 6/6 compliant)
EX = Open Frame, Through Hole
B = 1/2 Brick
Pin Length of Standard Product
Blank = 0.210 ” (5.33 mm)
Pin Length of Modified Standard Products
N = 0.145 ” (3.68 mm)
K = 0.110 ” (2.79 mm)
Output Wattage Class
250 = 250 Watts
Input Voltage
48 = 48 Volts (33 Vdc to 75 Vdc range)
Control Logic
Blank = Positive
R = Negative
Number of Outputs
S = Single
Blank = Standard Product
Z = Zero Undershoot,
Soft Turn-off Characteristic
(Applies to 1.5 V, 1.8 V,
2.5 V and 3.3 V models only)
Output Voltage
1V2 = 1.2 V, 1V5 = 1.5 V etc
Notes
1
2
3
4
5
6
7
8
9
REGULATION
di/dt = 0.1 A/µs, Vin = 48 Vdc, Tc = 25 °C, load change = 0.5 lo max.
to 0.75 lo max. and 0.75 lo max. to 0.5 lo max.
The EXB250 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 119.
Recommended input fusing is a 10 A HRC 200 V rated fuse.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured with no external Pi filter. Significant reduction possible with
external filter. See Application Note 119.
Start-up into resistive load.
For the pin length of Modified Standard products please consult the
factory.
The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
PROTECTION
Short circuit
Continuous
Overvoltage
Non-latching clamp
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2 input voltage
and current requirements
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
File Name: exb250s.pdf Rev (02): 06 Dec 2005
EXB250 Series
Single output
DC-DC CONVERTERS
72-165 W High Efficiency DC-DC Converters
3
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
Ø0.040
(7 PLS)
Ø0.080
(2 PLS)
4
1.700 [43.18]
1.300 [33.02]
1.000 [25.40]
0.700 [17.78]
0.300 [7.62]
0.000 [0.00]
5
6
BOTTOM 7
VIEW
8
2
3
9
1
0.500 [12.70]
*0.21 [5.33]
M3x0.5 Threaded
Through (4 PLS)
*Standard available pin length.
0.145 (3.68) and 0.110 (2.79)
options also available. (See
Notes 8 and 9 for ordering details).
2.280 [57.91]
2.000
[50.80]
2.400
[60.96]
TOP
VIEW
0.200 [5.08]
0.190 [4.83]
1.900 [48.26]
Ø0.128 [Ø3.25]
(4 PLS)
Ø0.094 [Ø2.39]
(2 PLS)
0.000 [0.00]
0.300 [7.62]
1
9
0.700 [17.78]
2
1.300 [33.02]
1.700 [43.18]
3
8
7
6
4
5
Ø0.054 [Ø1.37]
(7 PLS)
1.000 [25.40]
ALL DIMENSIONS IN INCHES [mm]
Recommended Hole Pattern
PIN CONNECTIONS
PIN NUMBER
FUNCTION
1
+Vin
2
Remote On/Off
3
No Function
4
-Vin
5
-Vout
6
-Sense
7
Trim
8
+Sense
9
+Vout
International Safety Standard Approvals
UL/cUL : UL1950 File No. E135734
TÜV
TÜV Rheinland File No. 10401-336-0209. Licence No. 40013414
CB Scheme No.DE1-32227
Datasheet © Artesyn Technologies® 2005
The information and specifications contained in this datasheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. The information and specifications contained or described herein are subject to change in any manner at any time without notice. No rights under any patent
accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items: Application Note Longform Datasheet
www.artesyn.com
File Name: exb250s.pdf Rev (02): 06 Dec 2005