RHOMBUS-IND F-129G

PARAMETER
(1)
Inductance
(1)
Leakage Inductance
(1)
High Frequency
Data Line Filter
UNITS
85.0 Min.
µH
0.25 Max.
µH
12 Max.
pF
0.30 Max.
Ω
500 Min.
VRMS
20
MHz
10k Min.
MΩ
250
mW
Interwinding Capacitance
Primary DC Resistance
Isolation (HI-POT)
SRF (Ref.)
Insulation Resistance
Power Rating
3 Coils 6 Data Lines
F-129G
Schematic Diagram
Crosstalk 60 dB @ 5 MHz Nominal
50 dB @ 10 MHz Nominal
Longitudinal Conversion Loss
0 - 300KHz
56 dB Min.
300 KHz - 500KHz 52 db Min.
500 KHz - 1MHz
46 dB Min.
1MHz - 5 MHz
36 db Min.
Operating Temperature Range -40OC TO +85OC
Storage Temperature Range -55OC TO +125OC
Turns ratio 1:1 + 0%
Current Rating: 100mA
1
Tested at 100KHz and 500 mVRMS
Dimensions in inches (mm)
.285
(7.24)
.885
(22.48)
MAX.
MAX.
.205
(5.21)
MAX.
.020
(0.51)
TYP.
.050
(1.27)
TYP.
.100
(2.54)
TYP.
.015
(0.38)
TYP.
.030
(0.76)
TYP.
.008 R
(0.20)
.010
(0.25)
TYP.
.430 (10.92)
.400 (10.16)
1/25/01
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
High Frequency
Data Line Filter:
P/N F-129G
Impedance
Impedance
(Ω)
3500
3000
2500
2000
1500
1000
500
1 MHz
Frequency
500 MHz
Crosstalk
Crosstalk ( dB )
- 40
- 50
- 60
- 70
- 80
1 MHz
Frequency
10 MHz
7/29/97
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971
Crosstalk
D.U.T = F-129G
Sine Wave 2VRMS
up to 10MHz
RS = 50 Ω
RL = 135 Ω
20 Log V/E
Longitudinal Conversion Loss
D.U.T = F-129G
Resistors Matched to within 0.03%
R1 + R2 = 67.5 Ω
R3 + R4 = 67.5 Ω
20 Log EL/ETr
Rhombus
Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971