TAIYO-YUDEN FK2125TZ201C170T

Notice for TAIYO YUDEN products Please read this notice before using the TAIYO YUDEN products.
REMINDERS
■ Product information in this catalog is as of October 2012. All of the contents specified herein are subject to change
without notice due to technical improvements, etc. Therefore, please check for the latest information carefully before practical application or usage of the Products.
Please note that Taiyo Yuden Co., Ltd. shall not be responsible for any defects in products or equipment incorporating such products, which are caused under the conditions other than those specified in this catalog or individual
specification.
■ Please contact Taiyo Yuden Co., Ltd. for further details of product specifications as the individual specification is
available.
■ Please conduct validation and verification of products in actual condition of mounting and operating environment
before commercial shipment of the equipment.
■ All electronic components or functional modules listed in this catalog are developed, designed and intended for
use in general electronics equipment.(for AV, office automation, household, office supply, information service,
telecommunications, (such as mobile phone or PC) etc.). Before incorporating the components or devices into any
equipment in the field such as transportation,( automotive control, train control, ship control), transportation signal,
disaster prevention, medical, public information network (telephone exchange, base station) etc. which may have
direct influence to harm or injure a human body, please contact Taiyo Yuden Co., Ltd. for more detail in advance.
Do not incorporate the products into any equipment in fields such as aerospace, aviation, nuclear control, submarine system, military, etc. where higher safety and reliability are especially required.
In addition, even electronic components or functional modules that are used for the general electronic equipment,
if the equipment or the electric circuit require high safety or reliability function or performances, a sufficient reliability evaluation check for safety shall be performed before commercial shipment and moreover, due consideration to
install a protective circuit is strongly recommended at customer's design stage.
■ The contents of this catalog are applicable to the products which are purchased from our sales offices or distributors (so called“TAIYO YUDEN’
s official sales channel”).
It is only applicable to the products purchased from any of TAIYO YUDEN’s official sales channel.
■ Please note that Taiyo Yuden Co., Ltd. shall have no responsibility for any controversies or disputes that may occur in connection with a third party's intellectual property rights and other related rights arising from your usage of
products in this catalog. Taiyo Yuden Co., Ltd. grants no license for such rights.
■ Caution for export
Certain items in this catalog may require specific procedures for export according to“Foreign Exchange and Foreign Trade Control Law”of Japan,“U.S. Export Administration Regulations”, and other applicable regulations.
Should you have any question or inquiry on this matter, please contact our sales staff.
13
MULTILAYER EMI SUPPRESSION FILTERS
REFLOW
■ FEATURES
■ APPLICATIONS
◦2×1.25mm size EMI filter unifying multilayer capacitor and inductor T
series with rapid attenuation characteristics and TZ series with effective maintaining of waveform quality of digital signal are lined up.
◦Noise countermeasure in visual signal such as DVD, DSC, PDP, etc.
(T series)
◦Noise countermeasure and maintaining waveform quality in digital
signal processing circuit in personal computer, communication equipment, etc. (TZ series)
◦Same shape as multilayer capacitor which is suitable for high speed mounting by automatic machine.
■ OPERATING TEMPERATURE RANGE
◦-25~+85℃
■ ORDERING CODE
【T Series】
/ MULTILAYER EMI SUPPRESSION FILTERS
NOISE SUPPRESSION COMPONENTS
F
K
2
1
❶
FK
2
5
T
❷
❶Type
Multilayer EMI
Suppression Filter
2
❸
❸Equivalence circuit
T
T type
5
6
❹
L ー T ○
❺
❻
❼
❻Rated Voltage[V]
L
10
❹Cutoff frequency
example
186
256
A
ーT
❽
❼Packaging
Tape & Reel
△
❽Internal Code
Standard products
△=Blank space
18 MHz
25 MHz
❷External dimensions
(L×W)[mm]
2125(0805) 2.0×1.25
❺Characteristic
example
Sharp
A
【TZ Series】
F
K
2
❶
FK
❶Type
Multilayer EMI
Suppression Filter
1
2
5
T
❷
Z
❸
2
0
1
C
8
5
❹
❸Equivalence circuit
T
T type
❺
❹Nominal Impedance
[100MHz]
Z700
70Ω
Z101
100Ω
Z201
200Ω
❷External dimensions
(L×W)[mm]
2125(0805) 2.0×1.25
T ○
0
❺Nominal Capacitance
[1MHz]
C170
17pF
C500
50pF
C850
85pF
T
❻
❻Packaging
Tape & Reel
△
❼
❼Internal Code
Standard products
△=Blank space
■ EXTERNAL DIMENSIONS/STANDARD QUANTITY
L
W
T
e1
e2
Standard Quantity [pcs]
Embossed tape
2.0±0.2
(0.079±0.008)
1.25±0.2
(0.049±0.008)
1.0±0.2
(0.039±0.008)
0.3±0.2
(0.012±0.008)
0.4±0.2
(0.016±0.008)
3000
Unit : mm (inch)
■ PART NUMBERS
●T Series
Ordering code
EHS (Environmental
Hazardous
Substances)
Cut-Off
Frequency
FK2125T186AL
FK2125T256AL
FK2125T406AL
FK2125T107AL
FK2125T167AL
FK2125T207AL
FK2125T407AL
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
18MHz±3.6MHz
25MHz±5MHz
40MHz±10MHz
100MHz±20MHz
160MHz±30MHz
200MHz±40MHz
400MHz±80MHz
Characteristic
DC
Rated
Rated Insulation
attnuation
resistance
insertion-loss
Voltage current resistance
max.
[1MHz] [50MHz] [100MHz][200MHz][350MHz][500MHz][600MHz][800MHz]
≧20dB
≧20dB
ー
ー
≧20dB
ー
ー
≧15dB
≧20dB
ー
ー
≧20dB
ー
ー
2Ω
ー
≧15dB
≧20dB
ー
≧20dB
ー
ー
100mA
≦1.0dB
ー
ー
≧20dB
ー
≧20dB
ー
ー
3Ω 10V DC
≧30MΩ
DC
ー
ー
ー
≧20dB
≧20dB
ー
ー
ー
ー
ー
≧20dB
≧20dB
ー
ー
2Ω
ー
ー
ー
ー
ー
≧20dB
≧20dB
●TZ Series
Ordering code
FK2125TZ700C170
FK2125TZ700C500
FK2125TZ700C850
FK2125TZ101C170
FK2125TZ101C500
FK2125TZ101C850
FK2125TZ201C850
EHS (Environmental
Hazardous
Substances)
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
RoHS
impedance
(terminal1-3)
[100MHz]
70Ω±30%
70Ω±30%
70Ω±30%
100Ω±30%
100Ω±30%
100Ω±30%
200Ω±30%
capacitance
(terminal1-2)
[1MHz]
17pF±20%
50pF±20%
85pF±20%
17pF±20%
50pF±20%
85pF±20%
85pF±20%
DC resistance
max.
Rated
Voltage
Rated
current
Insulation
resistance
2Ω
10V DC
100mA
DC
≧30MΩ
▶This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
112
13
MULTILAYER EMI SUPPRESSION FILTERS
■PACKAGING
①Minimum Quantity
●Taped package
Type
FK 2125(0805)
Thickness
mm(inch)
1.0(0.039)
Standard Quantity [pcs]
Embossed tape
3000
②Tape material
●Embossed Tape
③Taping dimensions
●Embossed tape 8mm wide (0.031 inches wide)
Type
FK 2125(0805)
Chip cavity
A
B
1.5±0.2
2.3±0.2
(0.059±0.008)
(0.091±0.008)
Insertion pitch
F
4.0±0.1
(0.157±0.004)
Tape thickness
K
T
2.0 max.
0.3 max.
(0.079 max.)
(0.012 max.)
Unit : mm(inch)
④Leader and Blank portion
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
emifilter_pack_e-01
⑤Reel size
Unit : mm(inch)
⑥Top tape strength
The top tape requires a peel;-off force of 0.1~0.7N in the direction of the arrow as illustrated below.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
emifilter_pack_e-01
MULTILAYER EMI SUPPRESSION FILTERS
■RELIABILITY DATA
1. Operating Temperature Range
Specified Value
-25~+85℃
2. Storage Temperature Range
Specified Value
-25~+85℃
3. Rated Voltage
Specified Value
10V DC
4. Rated Current
Specified Value
100mA DC
5. Cutoff frequency (T Series)
Specified Value
18MHz±3.6MHz, 25MHz±5MHz, 40MHz±10MHz, 100MHz±20MHz,
160MHz±30MHz, 200MHz±40MHz, 400MHz±80MHz
Test Methods and
Remarks
Measuring equipment
Measuring source
Input-Output impedance
: 8753D (or its equivalent)
: 0dBm
: 50Ω
6. Impedance (TZ Series)
Specified Value
70Ω±30%, 100Ω±30%, 200Ω±30%
Test Methods and
Remarks
Measuring
Measuring
Measuring
Measuring
frequency
equipment
jig
source
:
:
:
:
100MHz
4291A (or its equivalent)
16192A
-20dBm
7. Capacitance (TZ Series)
Specified Value
17pF±20%, 50pF±20%, 85pF±20%
Test Methods and
Remarks
Measuring equipment
: 4194A (or its equivalent)
Measuring voltage
: 0.5V
Measuring frequency
: 1MHz
Capacitance measurement between Terminals 1 and 2.
8. DC Resistance
Specified Value
2Ω max., 3Ω max. (FK2125T107AL)
Test Methods and
Remarks
Conduct measurement between Terminals 1 and 3.
9. Insulation Resistance
Specified Value
30MΩ min.
Test Methods and
Remarks
Conduct measurement between Terminals 1 and 2.
Applied voltage : 10VDC
10. Resistance to Flexure of Substrate
Specified Value
No mechanical damage.
Warp
: 2mm
Testing board : glass epoxy-resin substrate
Thickness
: 0.8mm
Test Methods and
Remarks
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
emifilter_reli_e-01
11. Solderability
Specified Value
At least 75% of terminal electrode is covered by new solder.
Test Methods and
Remarks
Solder temperature
Duration
Preheating temperature
Preheating time
Flux
:
:
:
:
:
230±5℃
4±1 sec.
150 to 180℃
2 to 3 min.
Immersion into methanol solution with colophony for 3 to 5 sec.
12. Resistance to Soldering
Specified Value
No significant abnormality in appearance.
Test Methods and
Remarks
Solder temperature
Duration
Preheating temperature
Preheating time
Flux
:
:
:
:
:
260±5℃
10±0.5 sec.
150 to 180℃
2 to 3 min.
Immersion into methanol solution with colophony for 3 to 5 sec.
13. Thermal Shock
Specified Value
Test Methods and
Remarks
No mechanical damage.
Insulation resistance (between 1 and 2)
DC resistance (between 1 and 3)
: 20MΩ min.
: 2Ω max.
: 3Ω max. (FK2125T107AL)
Conditions for 1 cycle
Step
Temperature (℃)
1
Minimum operating temperature +0/-3
2
Room temperature
3
Maximum operating temperature +3/-0
4
Room temperature
Number of cycles
Recovery
Duration (min)
30±3
2 to 3
30±3
2 to 3
:5
: 2 to 3 hrs of recovery under the standard condition after the test.
14. Damp Heat steady state
Specified Value
Test Methods and
Remarks
No mechanical damage.
Insulation resistance (between 1 and 2)
DC resistance (between 1 and 3)
Temperature
Humidity
Duration
Recovery
:
:
:
:
: 20MΩ min.
: 2Ω max.
: 3Ω max. (FK2125T107AL)
40±2℃
90 to 95%RH
500±12 hrs
2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
15. Loading under Damp Heat
Specified Value
Test Methods and
Remarks
No mechanical damage.
Insulation resistance (between 1 and 2)
DC resistance (between 1 and 3)
Temperature
Humidity
Applied voltage
Applied current
Duration
Recovery
: 20MΩ min.
: 2Ω max.
: 3Ω max. (FK2125T107AL)
: 40±2℃
: 90 to 95%RH
: Rated voltage (between 1 and 2)
: Rated current (between 1 and 3)
: 500±12 hrs
: 2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
16. Loading at High Temperature
Specified Value
Test Methods and
Remarks
No mechanical damage.
Insulation resistance (between 1 and 2)
DC resistance (between 1 and 3)
Temperature
Applied voltage
Applied current
Duration
Recovery
: 20MΩ min.
: 2Ω max.
: 3Ω max. (FK2125T107AL)
: 85±2℃
: Rated voltage (between 1 and 2)
: Rated current (between 1 and 3)
: 500±12 hrs
: 2 to 3 hrs of recovery under the standard condition after the removal from test chamber.
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
emifilter_reli_e-01
Note on standard condition :
"standard condition" referred to herein is defined as follows :
5 to 35℃ of temperature, 45 to 85% relative humidity and 86 to 106kPa of air pressure.
When there are questions concerning measurement results:
In order to provide correlation data, the test shall be conducted under condition of 20±2℃ of temperature, 60 to 70% relative humidity and 86 to 106kPa of
air pressure.
Unless otherwise specified, all the tests are conducted under the "standard condition."
※Circuit diagram
▶ This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/) .
emifilter_reli_e-01