rev. page page 1 of 4 date date 10/2007 DESCRIPTION: AC-DC converter PART NUMBER: FSK-S5 series features ·approved to UL60950, CSA C22.2 NO.60950, CB(IEC 60950), CE(EN60950) • universal input 85~264 Vac/ 110~340 VDC • encapsulated, compact case • high efficiency • surface mounting technology • 100kHz fixed frequency • fixed output voltage • thermal shutdown • output short circuit protection • low output ripple and noise • isolated output • 2 year warranty model number FSK-S5-3R3U FSK-S5-5U FSK-S5-12U FSK-S5-15U FSK-S5-24U power max. 4.125 W 5.0 W 5.0 W 5.0 W 5.0 W ripple & noise max. 80 mVp-p 80 mVp-p 120 mVp-p 150 mVp-p 200 mVp-p min 47 85 110 nom (50~60) max 440 264 340 150 80 20 40 0.5 0.75 units Hz VAC VDC mA mA A A mA mA parameter conditions/description voltage tolerance ripple and noise line regulation load regulation dynamic load regulation min -2% -1% -1% -1% -3% nom max +2% +1% +1% +1% +3% units temperature drift rise time -1% AC AC AC AC AC input voltage 85-264V / DC 110-340V 85-264V / DC 110-340V 85-264V / DC 110-340V 85-264V / DC 110-340V 85-264V / DC 110-340V output voltage 3.3V @ 1.25A 5V @ 1.0A 12V @ 0.42A 15V @ 0.33A 24V @ 0.21A INPUT parameter input frequency input voltage input current inrush current leakage current conditions/description output power derated from 85-90 VAC AC input of 110 VAC AC input of 220 VAC measured at 110 VAC at full load, cold start measured at 220 VAC at full load, cold start measured at 110 VAC measured at 220 VAC OUTPUT hold-up time 10 +1% 100 mS mS 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 efficiency (%) 71 75 77 77 77 rev. PART NUMBER: FSK-S5 series page 2 of 4 date 10/2007 DESCRIPTION: AC-DC converter PROTECTION CIRCUIT parameter conditions/description output over current over temperature works at over 105% of the rating and recovers automatically. 150 ºC over voltage clamp, 130~150% GENERAL parameter operating temp. conditions/description storage temp. operating humid. storage humid. isolation voltage (HI-POT) vibration impact MTBF RoHS safety EMC 1 warranty -40 80 ºC non-condensing 20% 90% RH non-condensing 20% 90% RH applied for 1 minute, 10mA primary to secondary, 500 Vdc @ 100 MΩ 3000 VAC at 10G 3 minute period 10 55 Hz 50G for 11mS, once on each X, Y, Z axis 4.5 x 10 5 hours yes approved to UL60950-1(E222889), CSA C22.2 NO.60950, CB(IEC 60950-1), CE(EN60950) 5W, 10W single output: approved; EN61204-3 class B, EN 6100-3-3 (through TUV) standard warranty length 2 years note: min -20 nom max 70 units ºC 1. to meet the standard of EN61204-3 class B, use the external noise filter between L and N (refer to manual) DERATING CURVE 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 rev. page 3 of 4 date 10/2007 DESCRIPTION: AC-DC converter PART NUMBER: FSK-S5 series EMI The figure below is a suggested diagram in order to reduce electromagnetic interference (EMI) on the FSK-S5 series. N VOUT C2 222Y2 C1 224X2 L1 = 10~30mH Common Mode Line Filter C1 = 220nF X2 Capacitor C2, C3 = 2200pF Y2 Capacitor C4 = 2200pF Y1 Capacitor SM PS L GND IN P U T L1 L /F C3 222Y2 F .G . OUTPUT C4 222Y1 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2382 REV. A R 0.3 [0.012] (8 PLCS) 50.8 2.000 DESCRIPTION NEW DRAWING DATE 9/13/2007 25.40 1.000 15.24 0.600 45.72 1.800 5.08 0.200 5 (PLCS) 2 IN 20.32 0.800 OUT TOLERANCE: ±0.3mm UNLESS OTHERWISE SPECIFIED 10.16 0.400 5 1 PIN ASSIGNMENTS Single Output Pin Number 1 AC (N) PC FILE NAME: FSK-S5 COPYRIGHT 2007 BY CUI INC. 1. 2. 3. 4. RoHS 4 Notes: All dimensions are in mm [inches] Weight: 40g or less Case material : PBT, UL94V-0 Construction: Encapsulated soft pot 2 3 4 5 AC (L) NO pin -V out +V out 20050 SW 112th Ave. Tualatin, OR 97062 Phone: 503-612-2300 800-275-4899 Fax: 503-612-2383 Website: www.cui.com TITLE: REV: AC-DC Converter PART NO. FSK-S5 DRAWN BY: JMS A UNITS: MM [INCHES] APPROVED BY: SCALE: 1:1