Solid-state Relay G3NE Compact, Low-cost, SSR Switching 5 to 20 A • Wide load voltage range: 75 to 264 VAC. Both 100-V and 200V loads can be handled with the same model. • Dedicated, compact aluminum PCB and power elements used. • Built-in varistor effectively absorbs external surges. • Quick-connect #110 input terminals and #250 output connections. • UL, CSA, and IEC/EN (TÜV) approval obtained for “-US” models. Ordering Information ■ List of Models Isolation Zero cross function Phototriac Yes Indicator No Rated output load 5 A at 100 to 240 VAC Rated input voltage 5, 12, 24 VDC G3NE-205T G3NE-205T-US G3NE-205T-2-US G3NE-210T G3NE-210T-US G3NE-210T-2-US G3NE-220T G3NE-220T-US G3NE-220T-2-US G3NE-205TL G3NE-205TL-US G3NE-205TL-2-US G3NE-210TL G3NE-210TL-US G3NE-210TL-2-US G3NE-220TL G3NE-220TL-US G3NE-220TL-2-US 10 A at 100 to 240 VAC 20 A at 100 to 240 VAC No Model 5 A at 100 to 240 VAC 10 A at 100 to 240 VAC 20 A at 100 to 240 VAC Note: When ordering, specify the input voltage. ■ Accessories (Order Separately) Heat Sinks Model SSR The following heat sinks are thin and can be DIN-track mounted. See Dimensions for details. Applicable SSR Y92B-N50 G3NE-205T(L)(-2)(-US)/-210T(L)(-2)(-US) Y92B-N100 G3NE-220T(L)(-2)(-US) Specifications ■ Ratings Input Rated voltage Operating voltage Voltage level Must operate Must release Input impedance With zero cross function Without zero cross function 5 VDC 4 to 6 VDC 4 VDC max. 250 Ω±20% 300 Ω±20% 12 VDC 9.6 to 14.4 VDC 9.6 VDC max. 600 Ω±20% 800 Ω±20% 24 VDC 19.2 to 28.8 VDC 19.2 VDC max. 1.6 kΩ±20% 1 VDC min. Note: Each model has 5-VDC, 12-VDC, and 24-VDC input versions. Solid-state Relay G3NE J-17 Output Model Applicable load Rated load voltage Load voltage range Load current (See note 1.) With heat sink 75 to 264 VAC Without heat sink 0.1 to 5 A 0.1 to 5 A 60 A (60 Hz, 1 cycle) G3NE-210T(L)-(-2)(US) 0.1 to 10 A (See note 2.) 0.1 to 5 A 150 A (60 Hz, 1 cycle) G3NE-220T(L)-(-2)(US) 0.1 to 20 A (See note 2.) 0.1 to 5 A 220 A (60 Hz, 1 cycle) G3NE-205T(L)-(-2)(US) 100 to 240 VAC Inrush current Note: 1. The load current varies depending on the ambient temperature. Refer to Load Current vs. Ambient Temperature under Engineering Data for details. 2. These values apply when using a dedicated radiator or a radiation plate of specified size. ■ Characteristics Item G3NE-2@@T-(-2)(US) Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.6 V (RMS) max. Leakage current 2 mA max. (at 100 VAC) 5 mA max. (at 200 VAC) G3NE-2@@TL-(-2)(US) 1 ms max. Insulation resistance 100 MΩ min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Shock resistance Destruction: 1,000 m/s2 Ambient temperature Operating: –30°C to 80°C (with no icing or condensation) Storage: –30°C to 100°C (with no icing or condensation) Ambient humidity Operating: 45% to 85% Approved standards (only for -US models) UL508 File No.E64562/CSA C22.2 (No.0, No.14) File No. LR35535 TÜV R9051064 (VDE0435) (EN60950) Weight Approx. 37 g Engineering Data Load Current vs. Ambient Temperature G3NE-210T(L)-(-2)(US) Load current (A) Load current (A) J-18 Solid-state Relay G3NE With standard heat sink (Y92B-N100) or aluminum plate measuring 300 mm x 300 mm x t3 mm (W x H x D) With standard heat sink (Y92B-N50) or aluminum plate measuring 100 mm x 100 mm x t2 mm (W x H x D) Without heat sink Ambient temperature (°C) G3NE-220T(L)-(-2)(US) Without heat sink Ambient temperature (°C) Load current (A) G3NE-205T(L)-(-2)(US) Without heat sink Ambient temperature (°C) Inrush Current Resistivity: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. Inrush current (A. Peak) G3NE-220T(L)-(-2)(US) Inrush current (A. Peak) G3NE-210T(L)-(-2)(US) Inrush current (A. Peak) G3NE-205T(L)-(-2)(US) Energizing time (ms) Energizing time (ms) Energizing time (ms) Dimensions Note: All units are in millimeters unless otherwise indicated. G3NE-205T(L)/210T(L)/220T(L)-(-2)(US) 3.5 dia. hole Terminal Arrangement/ Internal Connections (Top View) 47.5 max. 37.5 max. 14.5 Input voltage Two #110 (t = 0.5) (Faston tab or equivalent)* 6.5 Two #250 (t = 0.8) (Faston tab or equivalent) Input 4− Output Load 2 Load power supply 7.95 7.1 2.9 6 11.5 max. 3 Mounting Holes Two, 3.5-dia. or M3 holes * G3NE-2@@T(L)-2-US: Two, #187 (t=0.5) (Faston tab or equivalent) 30±0.2 Mounting Holes 4.6 dia. hole Two, M3 holes Two, M4 holes Two, 3.2-dia. holes 44 max. 30 35 30.5±0.3 47.6 5.6 5 77 max. 90±0.3 100 max. Y92B-N100 4.6 dia. hole Two, M3 holes 47 max. 6 4.5 51 max. Weight: approx. 200 g 35±0.2 Two, M4 holes Two, 3.2-dia. holes Mounting Holes 71 max. 30 35 30.5±0.3 90±0.4 Two, 4.4-dia. or M4 holes SSR Heat Sink Y92B-N50 1 3+ 30+0.5 75 max. 90±0.4 47.6 77 max. 5 5.6 28 100 max. 13 4.5 Two, 4.4-dia. or M4 holes 90±0.3 100 max. 35±0.2 Weight: approx. 400 g Solid-state Relay G3NE J-19 Precautions Refer to the Technical Information for SSRs (Cat. No. J137) for general precautions. ■ Correct Use Do not apply excessive force to the terminals. Exercise care when pulling or inserting the terminal clips for the Quick Connector (QC). When attaching a heat sink to the G3NE, in order to facilitate heat dissipation, apply heat conductive grease on the heat sink. Tighten the mounting screws of the heat sink with a torque of 0.59 to 0.98 N·m. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. K062-E1-03 J-20 In the interest of product improvement, specifications are subject to change without notice. Solid-state Relay G3NE