ETC G7L-1A-T-CB-AC12

General Purpose Relay
■
■
■
■
■
■
G7L
A high-capacity, high-withstand voltage relay
compatible with mometary voltage drops
No contact chattering for mometary voltage
drops up to 50% of rated voltage
UL Class B construction standard
Wide-range AC-activated coil that handles
100 to 120 VAC at either 50 or 60 Hz
Miniature hinge for maximum switching
capacity, particularly for inductive loads
Flame resistant materials (UL94V-0-qualifying) used for all insulation material
Quick-connect, screw, and PCB terminals
available
■ Standard models are UL, CSA, and TUV
approved; VDE versions now available
■ Conforming to IEC 950
■
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Replaces G5D series.
Type
E bracket
E bracket
(with test button)
Upper bracket
Upper bracket
(with test button)
PCB mounting
Contact form
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
Part number
Quick-connect terminal
G7L-1A-T-CB (see note 1)
G7L-2A-T-CB (see note 1)
G7L-1A-TJ-CB (see note 1)
G7L-2A-TJ-CB (see note 1)
G7L-1A-TUB-CB
G7L-2A-TUB-CB
G7L-1A-TUBJ-CB
G7L-2A-TUBJ-CB
—
—
Screw terminal
G7L-1A-B-CB (see note 1)
G7L-2A-B-CB (see note 1)
G7L-1A-BJ-CB (see note 1)
G7L-2A-BJ-CB (see note 1)
G7L-1A-BUB-CB
G7L-2A-BUB-CB
G7L-1A-BUBJ-CB
G7L-2A-BUBJ-CB
—
—
PCB terminal
—
—
—
—
—
—
—
—
G7L-1A-P-CB
G7L-2A-P-CB
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and
part numbers.
2. For VDE approved versions, please consult OMRON.
G7L
G7L
■ MODEL NUMBER LEGEND
G7L- ■ ■
■- ■ ■ ■ ■
1 2 3 4 5 6
1. Contact form
1A: SPST-NO
2A: DPST-NO
3. Mounting construction
No symbol: E bracket type
UB:
Upper bracket type
2. Terminal shape
T:
Quick-connect terminals
P:
PCB terminals
B:
Screw terminals
4. Special functions
No symbol: Without test button
J:
With test button
5. 80: VDE approved version
(includes UL, CSA and TÜV)
6. CB: Class B insulation
7. Rated coil voltage
■ ACCESSORIES
Quick-connect terminals
Description
E-brackets
Track mounting adaptor
Front connecting socket
Cover
Model
Contact form
SPST-NO
G7L-1A-T
G7L-1A-TJ
DPST-NO
G7L-2A-T
G7L-2A-TJ
Model
Contact form
SPST-NO
G7L-1A-B
G7L-1A-BJ
DPST-NO
G7L-2A-B
G7L-2A-BJ
Part number
R99-07G5D
P7LF-D
P7LF-06 (see note)
P7LF-C
Screw terminals
Description
E-brackets
Track mounting adaptor
Part number
R99-07G5D
P7LF-D
Note: P7LF-C cover is supplied with the P7LF-06 socket.
Specifications
■ CONTACT DATA
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
G7L-1A-T, G7L-1A-B
Resistive load
Inductive load
(cosϕ = 1)
(cosϕ = 0.4)
30 A, 220 VAC
25 A, 220 VAC
AgCdO
30 A
250 VAC
30 A
6,600 VA
5,500 VA
100 mA, 5 VDC
G7L-2A-T, G7L-2A-B
Resistive load
Inductive load
(cosϕ = 1)
(cosϕ = 0.4)
G7L-1A-P, G7L-2A-P
Resistive load
Inductive load
(cosϕ = 1)
(cosϕ = 0.4)
20 A, 220 VAC
25 A
20 A
25 A
20 A
4,400 VA
Note: P level: λ60 = 0.1 x 10-6 operation.
■ COIL INTERNAL CIRCUIT
DC operating coil
2
AC operating coil
G7L
G7L
■ COIL DATA
AC
Rated voltage
(V)
Rated current
(mA)
Resistance
(Ω)
6
12
24
50
100/120
200/240
283
142
71
34
17.00/20.40
8.50/10.20
18.90
75
303
1,310
5,260
21,000
Rated voltage
(V)
Rated current
(mA)
Resistance
(Ω)
6
12
24
48
100
317
158
79
40
19
18.90
75
303
1,220
5,260
Must operate
Must release
% of rated voltage
75% max.
15% min.
Max. voltage
Power
consumption
110% max.
Approx.1.70
to 2.50 VA
75 volts
150 volts
132 volts
264 volts
18 volts
36 volts
DC
Must operate
Must release
% of rated voltage
75% max.
15% min.
Max. voltage
Power
consumption
110% max.
Approx.1.90 W
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for
AC rated current and ±15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).
■ CHARACTERISTICS
Contact resistance
Operate time
Release time
Max. operating
frequency
Mechanical
Electrical
Insulation resistance
Dielectric strength
Impulse withstand voltage
Vibration
Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Life expectancy
Mechanical
Electrical
Ambient temperature
Humidity
Weight
50 mΩ max.
30 ms max.
30 ms max.
1,800 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)
Between coil and contact: 10,000 V (impulse wave used: 1.20 x 50 µs)
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
1,000 m/s2 (approx. 100 G)
1,000 m/s2 (approx.10 G)
5,000,000 operations min. (at 1,800 operations/hour)
100,000 operations min. (at 1,800 operations/hour under rated load)
-20° to 85°C (-4° to 185°F)
35% to 85% RH
Quick-connect terminal type: approx. 90 g (3.17 oz)
PCB terminal type: approx. 100 g (3.52 oz)
Screw terminal type: approx. 120 g (4.23 oz)
Note: Data shown are of initial value.
3
G7L
G7L
■ CHARACTERISTIC DATA
Electrical service life
Switching current (A)
Service life (x 103 operations)
Maximum switching capacity
Switching voltage (V)
Switching current (A)
Dimensions
Unit: mm (inch)
■ RELAYS
G7L-1A-T
(E Bracket Attached)*
G7L-2A-T
(E Bracket Attached)*
* E bracket must be ordered separately.
4
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L
G7L-1A-TJ
(E Bracket Attached)*
G7L-2A-TJ
(E Bracket Attached)*
G7L
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-1A-TUB
G7L-2A-TUB
* E bracket must be ordered separately.
5
G7L
G7L
Unit: mm (inch)
■ RELAYS (continued)
G7L-1A-TUBJ
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-TUBJ
G7L-1A-B
(E bracket Attached)*
G7L-2A-B
(E bracket Attached)*
* E bracket must be ordered separately.
6
G7L
G7L-1A-BJ
(E bracket Attached)*
G7L-2A-BJ
(E bracket Attached)*
G7L
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-1A-BUB
G7L-2A-BUB
* E bracket must be ordered separately.
7
G7L
G7L
Unit: mm (inch)
■ RELAYS (continued)
G7L-1A-BUBJ
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-BUBJ
G7L-1A-P
G7L-2A-P
8
G7L
G7L
■ ACCESSORIES
E bracket
R99-07G5D
Adaptor
P7LF-D
Front connecting socket
P7LF-06
Mounting holes
(Bottom view)
Mounting holes
(Bottom view)
Mounting holes
(Bottom view)
Note: 1. To protect against electric shock, use the P7LF-C cover on terminals.
2. P7LF-C cover is supplied with P7LF-06 socket
9
G7L
G7L
Unit: mm (inch)
■ ACCESSORIES (continued)
Cover
P7LF-C
Note: P7LF-C cover is supplied with P7LF-06 socket
Mounting track
PFP-100N, PFP-50N
PFP-100N2
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.
2. L = Length
PFP-100N ................. L = 1 m (39.00 in)
PFP-50N ................. L = 50 cm (19.60 in)
PFP-100N2 ............... L = 1 m (39.00 in)
End plate
PFP-M
Spacer
PFP-S
10
G7L
G7L
■ APPROVALS
UL recognized type (File No. E41643)/ CSA certified type (File No. LR35535)
Type
Contact form
G7L-1A-T-CB
SPST-NO
G7L-1A-TJ-CB
G7L-1A-TUB-CB
G7L-1A-TUBJ-CB
G7L-1A-B-CB
G7L-1A-BJ-CB
G7L-1A-BUB-CB
G7L-1A-BUBJ-CB
G7L-1A-P-CB
Terminal type
Quick-connect
G7L-2A-T-CB
DPST-NO
G7L-2A-TJ-CB
G7L-2A-TUB-CB
G7L-2A-TUBJ-CB
G7L-2A-B-CB
G7L-2A-BJ-CB
G7L-2A-BUB-CB
G7L-2A-BUBJ-CB
G7L-2A-P-CB
Quick-connect
Screw
PCB
Screw
PCB
Contact ratings
30 A, 277 VAC (Resistive) 30,000 c
30 A, 120 VAC (General purpose) 30,000 c
30 A, 277 VAC (General purpose) 30,000 c
1.5 kW, 120 VAC (Tungsten)
1.5 HP, 120 VAC
3 HP, 240/265/277 VAC
20 FLA/120 LRA, 120 VAC, 30,000 c
17 FLA/102 LRA, 277 VAC, 30,000 c
TV-10, 120 VAC
20 A (2.4 kW), 120 VAC (Tungsten)
30 A, 277 VAC (Resistive) 30,000 c
30 A, 120 VAC (General purpose) 30,000 c
30 A, 277 VAC (General purpose) 30,000 c
1.5 kW, 120 VAC (Tungsten)
1.5 HP, 120 VAC
3 HP, 240/265/277 VAC
20 FLA/120 LRA, 120 VAC, 30,000 c
17 FLA/102 LRA, 277 VAC, 30,000 c
TV-10, 120 VAC
20 A (2.4 kW), 120 VAC (Tungsten)
TÜV (File No. R9251551)
Type
Contact form
G7L-1A-T-CB
SPST-NO
G7L-1A-TJ-CB
G7L-1A-TUB-CB
G7L-1A-TUBJ-CB
G7L-1A-B-CB
G7L-1A-BJ-CB
G7L-1A-BUB-CB
G7L-1A-BUBJ-CB
G7L-1A-P-CB
Coil ratings
6, 12, 24, 48,
100, 110, 200,
220 VDC
Terminal type
Quick-connect
Contact ratings
25 A, 240 VAC, (cosϕ = 1)
25 A, 240 VAC, (cosϕ = 0.4)
12, 24, 50,
100/120, 200/240
VAC
Screw
30 A, 240 VAC, (cosϕ = 1)
25 A, 240 VAC, (cosϕ = 0.4)
30 A, 240 VAC, (cosϕ = 0.4)
PCB
20 A, 240 VAC, (cosϕ = 1)
20 A, 240 VAC, (cosϕ = 0.4)
25 A, 240 VAC, (cosϕ = 1)
25 A, 240 VAC, (cosϕ = 0.4)
G7L-2A-T-CB
DPST-NO
G7L-2A-TJ-CB
G7L-2A-TUB-CB
G7L-2A-TUBJ-CB
G7L-2A-B-CB
G7L-2A-BJ-CB
G7L-2A-BUB-CB
G7L-2A-BUBJ-CB
G7L-2A-P-CB
Quick-connect
Screw
25 A, 240 VAC, (cosϕ = 1)
25 A, 240 VAC, (cosϕ = 0.4)
PCB
20 A, 240 VAC, (cosϕ = 1)
20 A, 240 VAC, (cosϕ = 0.4)
VDE recognized type (Licence no. 1530 UG)
Note: 1. Please consult OMRON for details of VDE approvals.
2. The G7L relay conforms to the following standards: Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83
DIN VDE 0435 Teil 201 A1/05. 90
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81
DIN EN 60 950/VDE 0805/11. 93
EMC:
prEN 50082-2, EN 55022
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance
characteristics individually defined in this catalog.
4. In the interest of product improvement, specifications are subject to change.
11
G7L
G7L
Precautions
■ HANDLING
■ OPERATING COIL
• To preserve initial performance, do not drop or otherwise
subject the power relay to shock.
• As a rule, either a battery or a DC power supply with a
maximum 5% ripple is used for the operating voltage for DC
relays. Before using a rectified AC supply, confirm that the
ripple is not greater than 5%. Ripple greater than this can
lead to variations in the operating and reset voltages.
• The case is not designed to be removed during normal
handling and operation. Doing so may affect performance.
• Use the power relay in a dry environment free from
excessive dust, SO2, H2S, or organic gas.
As excessive ripple can generate beats, the insertion of a
smoothing capacitor is recommended as shown below.
• Do not allow a voltage greater than the maximum allowable
coil voltage to be applied continuously.
• Do not use the power relay outside of specified voltages and
currents.
• Do not allow the ambient operating temperature to exceed
the specified limit.
■ INSTALLATION
• Although there are not specific limits on the installation site,
it should be as dry and dust-free as possible.
• PCB terminal-equipped relays weigh approximately 100 g.
Be sure that the PCB is strong enough to support them. We
recommend dual-side through-hole PCBs to reduce solder
cracking from heat stress.
• Quick-connect terminals can be connected to fast on
receptacle #250 and positive-lock connectors.
• Allow suitable slack on leads when wiring, and do not
subject the terminals to excessive force.
■ CLEANING PCB TERMINALS
• When driving a transistor, check the leakage current and
connect a bleeder resistor if necessary.
• Momentary voltage drops on coil input voltage should not
exceed one second duration after contact mating with no
shock or vibration.
• PCB terminals have semi-sealed construction which
prevents flux from entering the relay base. It is
recommended that the user should apply a tape seal over
the vent hole prior to wave soldering or cleaning. The tape
should then be removed after processing.
■ APPLICATIONS
• Compressors for package air conditioners and heater
switching controllers
• Lamp control, motor drivers, and power supply switching in
copy machines, facsimiles, and other OA equipment
• Switching controllers for power tools or motors
• Lighting controllers
• Power controllers for water heaters
• Power controllers for packers or food processing equipment
• Power controllers for dryers
• Magnetron control in microwaves
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
12
01/00
Specifications subject to change without notice.
Printed in the U.S.A.