ETC 195-MB11

Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Contactors
Bulletin 100-M, 100-C,
CAB6
• Bulletin 100-M
2.2 … 5.5 kW
• Bulletin 100-C
4 … 45 kW
• Bulletin CAB6
45 … 220 kW
4
Pages
4-9 … 4-64
Bulletin 100S, 104S
Safety Contactors
w
e
N
• Bulletin 100S, 104S
4 … 45 kW
Bulletin 100-G
Contactors
Pages
4-65 … 4-78
• Bulletin 100-G
315 … 710 kW
Contactor Overview
AC-3 / 400 VAC
100-G (550…1200 A)
CAB6 (85…420 A)
100-C (9…85 A)
100-M (5…12 A)
[kW] 2.2
Rockwell Automation
4
5.5
45
220
710
4-1
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin 100-M
Connection module (Eco starter)
for circuit breakers 140M
4
Auxiliary contact block
2 poles
Miniature Contactor
100-M12N…
Auxiliary contact block
4 poles
Suppressor module
RC, Diode,
Varistor
Connecting kit
Latched miniature contactor
100-ML09N…
Mechanical
interlock
Timer
for pick-up delay
Timer for Y-∆ control
switching delay
Reversing contactor
104-M
4-2
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin 100-M
Minimum Space Requirements for Accessories
Auxiliary contact blocks and timers can be mounted onto the contactor
without requiring additional panel space.
4
Positive Guidance of the Contacts
Positive guidance of the contacts according to IEC 60947-5-1 is given
when it is ensured, that N.C. and N.O. contacts can never be closed at
the same time. Therefore a minimum opening distance of 0.5 mm is
prescribed in the event of failure. All contacts in the basic device are
positively guided as well as the normally closed contacts in the auxiliary
contact block except Bulletin 700-MB bifurcated contacts. This permits
use within safety controls.
High Contact Reliability
Bulletin 100-M Miniature Contactors are rated for extra-low voltage. In
addition to the isolation of the contact housing, high contact reliability is
ensured by the special design of the auxiliary contacts:
• cross-stamped in the main contactor
• in the auxiliary contact block and in the bifurcated contacts (see chapter 8, Bulletin 700-M timers), H-contact bridges with constant sliding
rolling motion and 4 multiple current path.
Rockwell Automation
4-3
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin 100-C
Connection module
for circuit breakers 140M
Interface
4
Suppressor module
RC, Diode, Varistor
Solid-State timing module
for Y-∆ control
switching delay
Solid-State timing module
pick-up delay
Contactor
100-C30, C37
Contactor
100-C09…C23
Pneumatic
timing module
4-4
Mechanical
latch
Connection set
Mechanical
interlock
Contactor
100-C60…C85
Contactor
100-C43
Auxiliary contact blocks
for side mounting
1- and 2-pole
Auxiliary contact blocks
for front mounting
2-pole
Auxiliary contact blocks
for front mounting
4-pole
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin 100-C, 100S-C
Compact design
Bulletin 100-C contactors switch more power and use less panel space. Despite
their small dimensions, they are powerful enough for use with the high starting
currents of today’s modern motors.
45 mm
9 A, 12 A,
16 A, 23 A
45 mm
30 A,
37 A
54 mm
43 A
72 mm
60 A, 72 A,
85 A
4
(AC-3 at 400/415 V)
Bulletin 100-C contactors for good connections
Two separate power connections per pole offer ease of wiring and high connection
reliability. The modern connection technology used by Bulletin 100-C contactors
saves both time and money.
Coil always positioned correctly
The dual connection technology always positions the coil connection for optimal
accessibility, whether below (on starters with circuit breakers), or above (on starters
using the revolutionary Bulletin 193-E Electronic Overload relay). Space- and costsaving coil modules (interface devices, protection elements, Electronic timers) can
always be added. When ordering, select the desired position of the coil connections. The position of the coil connections can also be adapted locally within seconds, using simple tools.
Uniform accessories for the entire line of contactors
All Bulletin 100-C accessories can be used with all contactor sizes.The mechanical
interlock with integrated interlock contacts can be used alone to interlock the smallest AC contactor with the largest.
Bulletin 100-C contactors for highest security
Bulletin 100-C contactors are rated for high personal protection and functional
security. The safety package consists of amongst other things
finger and back of hand accidental contact protection.
• Secure isolation of electric circuits
• Positively guided contacts
• Cover to prevent manual operation.
Comprehensive Safety for Operating Personnel and the Machine
The safety of both operators and machinery becomes more and more important.
Electrical controls can play an important contribution to safety. Various rules and
standards define the components and systems that are used in safety applications.
•
•
•
•
Positively guided contacts according to IEC 947-5-1
Fixed coupling of contactor and auxiliary contact block
Protection against unintended actuation
Auxiliary contacts that are electronically compatible according to DIN 19240
Positive Guidance of the Contacts
Positive guidance of contacts according to IEC 60947-5-1 is given when it
is ensured, that N.C. and N.O. contacts are never able to be closed at the same
time. Therefore a minimum opening distance of 0.5 mm is prescribed in the event
of failure. All contacts in the basic device are positively guided as well as the
normally closed contacts in the auxiliary contact block. The contacts in the basic
device as well as in the auxiliary contact blocks are guided restricted. The restricted
guidance also applies between basic device and accessories.
Rockwell Automation
4-5
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin CAB6
Terminal block
Star Bridge
4
Auxiliary contact block
Connection set
Contactor
CAB6-85…
Contactor
CAB6-210…
Mechanical
interlock
Auxiliary contact blocks
Suppressor module
RC, Diode, Varistor
Easy-to-wire coil connections
Interface integrated with CAB6-105-EI
Threaded connections
Max. 2 auxiliary contacts per
side, left- and right-side mounted
Completely enclosed arcing chamber
Isolated switching position inhibits
manual operation
4-6
Safety lock for arcing chamber and
contact holders
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin CAB6
Bulletin CAB6 Contactors with electronically controlled Coil Mechanism
Bulletin CAB6 contactors are equipped with electronically controlled coil mechanisms and integrated interface starting from size
CAB6-105-EI. Size CAB6-85 is equipped with conventional coils and sizes CAB6-105 and CAB6-140 can be equipped with either
conventional or electronic coils. Contactors with electronic coils are characterised by the -El suffix. By offering control options, a
multitude of possibilities are at the user's disposal:
• Integrated interface
The factory supplied CAB6-EI range features an interface module that can be
activated and deactivated via an externally accessible jumper unit. With the
interface, the contactor can be addressed directly by a 24 V DC signal from a
programmable logic controller. The max. allowable current of the interface is 15
mA (DIN VDE 19240). The Interface input is separated from the coil circuit by
photoelectric.
• Protective circuit included
All EI-type contactors have a protective circuit as standard.
• Low pick-up and holding power
When compared with conventional contactors, the current requirement is substantially lowered by the construction of the contactor, particularly via the electronic control.
• Wide voltage range
Despite the wide voltage range (e.g., 208...277 V AC) the min./max. values of
the IEC tolerances are kept between -0.85 and +1.1.
110 mm
• Compact dimensions
New, compact construction solutions and the application of electronics substantially reduces the dimensions. Two housing sizes cover the entire range from
85...420 A (AC-3). Simple and efficient wiring is ensured by the identical connection height of the main pole on both housing sizes.
CAB6-85…170
Bulletin CAB6 contactors can be mechanically interlocked, without needing additional mounting space.
CAB6-210…420
• Defined on- and off- points
Electronic control guarantees defined points of switching on and off, thus preventing chatter and damage to the contactor.
• Environmentally friendly
Construction and contact materials do not contain cadmium, asbestos or PCBs
and can be recycled at the end of the contactor life. Most plastic parts are characterised according to DIN 54840.
• Frame terminal blocks
Go safe! Contact protection is fulfilled by attachable terminal covers according
to DIN VDE 0106 and VBG 4. By using framework terminal blocks the contactor
automatically becomes finger-safe per IP20.
Rockwell Automation
4-7
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6, 100-G
Contactors
Overview - Bulletin 100-G / CA 5
Supply module
Contactor
100-G / CA 5
4
Mechanical interlock
(horizontal construction)
Auxiliary contact block
Mechanical interlock
(vertical construction)
Fourth pole
Coil sets
Mechanical latch
Good reasons to select Rockwell
Automation contactors
• Allen-Bradley contactors are built for a global marketplace
and fulfill all applicable IEC 947 requirements.
• Worldwide acceptance and high stock availability in all
countries increases security for the user.
• A wide range of accessories (e.g., auxiliary contact blocks,
interfaces, control and timing modules) make contactors
ideal and economical building blocks for individual
control needs.
4-8
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Bulletin 100-M
Miniature Contactors
• Bulletin 100-M
2.2 … 5.5 kW (5 … 12 A)
Bulletin 100-C, CAB6
Contactors
• Bulletin 100-C
4 … 45 kW (9 … 85 A)
• Bulletin 104-C
4 … 45 kW (9 … 85 A)
• Bulletin CAB6
45 … 220 kW (85 … 420 A)
Bulletin 100S, 104S
Safety Contactors
• Bulletin 100S-C
4 … 45 kW (9 … 85 A)
• Bulletin 104S-C
4 … 45 kW (9 … 85 A)
Table of Contents
Description
Page
Description
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Specifications
Product Selection
Page
Performance Data / Characteristics . . . . . . . . . . . . . . . . . . . . .4-36
AC Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-44
DC Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-12
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-49
Special Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-14
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-51
Reversing Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-16
Permissible Switching Rate . . . . . . . . . . . . . . . . . . . . . . . . . . .4-57
Safety Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-18
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-61
Accessories
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-24
Mounting Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-31
Labelling Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-33
Rockwell Automation
4-9
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
3-pole Contactors
• AC control
• 3 main contacts
4
100-M
100-C
CAB6
Auxiliary
Contacts
Integrated
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
AC-1
(40 °C)
[A]
100-C
[kW] ➊
230 V
400 / 415 V
[A]
500 V
690 V
230 V
400 / 415 V
500 V
690 V
1
0
100-M05N
0
1
100-M05N
1
0
100-M09N
20
3
4
4
—
12
9
7
—
0
1
100-M09N
1
0
100-M12N
20
3
5.5 ➋
4
—
12
12 ➋
7
—
0
1
100-M12N
1
0
100-C09
32
3
4
4
4
12
9
7
5
0
1
100-C09
1
0
100-C12
32
4
5.5
5.5
5.5
15
12
10
7
0
1
100-C12
1
0
100-C16
32
5.5
7.5
7.5
7.5
20
16
14
9
0
1
100-C16
1
0
100-C23
32
7.5
11
13
10
26.5
23
20
12
0
1
100-C23
0
0
100-C30
50
10
15
15
15
35
30
25
18
0
0
100-C37
50
11
18.5 / 20
20
18.5
38
37
30
21
0
0
100-C43
85
13
22
25
22
44
43
38
25
0
0
100-C60
100
18.5
32
37
32
62
60
55
34
0
0
100-C72
100
22
40
45
40
72
72
67
42
0
0
100-C85
100
25
45
55
45
85
85
80
49
0
0
CAB6-85-00160
25
45
55
80
85
85
85
85
1
1
CAB6-85-110
0
CAB6-105-001
1
CAB6-105-11160
32
55
63
100
105
105
105
105
0
0
CAB6-105-EI-001
1
CAB6-105-EI-110
0
CAB6-140-0080
110
140
140
115
115
1
1
CAB6-140-11250
45
75
0
0
CAB6-140-EI-0090
132
140
140
140
140
1
1
CAB6-140-EI-110
0
CAB6-170-EI-00250
55
90 / 100
110
160
170
170
170
170
1
1
CAB6-170-EI-110
0
CAB6-210-EI-00350
63
110
150
200
210
210
210
210
1
1
CAB6-210-EI-110
0
CAB6-250-EI-00350
80
132 / 150
160
250
250
250
250
250
1
1
CAB6-250-EI-110
0
CAB6-300-EI-00450
90
160
200
300
300
300
300
300
1
1
CAB6-300-EI-110
0
CAB6-420-EI-00500
132
220 / 250
420
420
300 ➌ 425 ➌
420 ➌ 420 ➌
1
1
CAB6-420-EI-11Bulletin CAB contactors are suitable for use with operating voltages up to 1000V. Bulletin CAB6-...-El contactors are equipped with electronic coil control
20
1.5
2.2
2.2
—
6.5
5.3
4
PQ
Cat. No.
—
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊕
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
3
31
3
31
3
31
10
01
10
01
10
01
10
01
00
00
00
00
00
00
✪
✪
✪
✪
✪
✪
✫
✫
✫
✫
✫
✫
✫
✫
✫
✫
1
1
➊ Power ratings: Preferred values according to IEC 60072-1
➋ Value applies only to AC-2 and AC-3
➌ Value applies only to AC-2 and AC-3; AC-4: 360 A
PQ = Package Quantity
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
4-10
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
Selection of Options
Options
Cat. No. Suffix
⊕ Coil connection position
⊗ Voltage suffix code
✪ Package quantity 100-M
✫ Package quantity 100-C
!
Description
No Entry
Ordering Example
Line-side coil connection (above, standard quantity)
U
e.g. KJ
No Entry
100-C09⊗10
Load-side coil connection (below)
Voltage suffix code from table below
Multi-pack (10 pieces) (Only KD, D, KF, KK)
100-C09U⊗10
100-C09KJ10
100-M09N⊗3
S
Single item (1 piece, standard quantity)
100-M09N⊗3S
No Entry
Single item (1 piece, standard quantity)
100-C09⊗10
Multi-pack (20 pieces)
100-C09⊗10M
M
4
Attention:
Bulletin 100-M…S: standard quantity = single item (1 piece)
Bulletin 100-C, CAB6: standard quantity = single item (1 piece)
⊗ Voltage Suffix Codes for AC Control
[V]
100-M
50 Hz
60 Hz
50/60 Hz
[V]
100-C
50 Hz
60 Hz
50/60 Hz
[V]
50 Hz
60 Hz
50/60 Hz
24
48
110
110120
230
240
380- 400400 415
—
—
KD
—
—
KH
D
—
—
—
D
—
—
—
KF
(A)
—
—
—
(A)
—
—
—
(KT)
KK
—
—
KK
—
12
24
32
36
42
48
100
100110
110
120
127
200
(R)
(Q)
—
(K)
(J)
KJ
(V)
—
—
(W)
(V)
—
(X)
—
—
(Y)
(X)
KY
(KP) —
— (KP)
(KP) —
(D)
—
KD
(P)
(D)
—
(S)
—
—
(KG)
—
—
(KG)
(KG)
—
—
—
(KL)
—
(L)
—
240
277
347
380
380400
400
400415
440
480
500
550
600
(VA) (T)
—
(A)
— (KA)
—
(T)
—
—
(I)
—
—
(E)
—
(N)
—
—
—
—
KN
(G)
—
—
(B)
(N)
(KB)
—
(B)
—
(M)
—
—
(C)
—
—
—
(C)
—
220230230
230
240
220- 230230 240
200220
200- 208230 240
(F)
—
—
—
—
KF
24
28
48
55
110
127
220230
230
240
260
277
380400
415
440460
480
05
—
—
—
05
—
08
—
—
—
08
—
10
—
(48)
—
10
—
13
—
—
—
—
54
(15)
—
(55)
—
13
—
—
(15)
—
16
—
—
(17)
—
—
—
16
—
—
(17)
—
2428
4365
50/60 Hz
05
08
10
14
16
CAB6-300-EI…CAB6-420-EI ➎ 50/60 Hz
—
08
10
14
16
[V]
CAB6-85…CAB6-140 ➍
50 Hz
60 Hz
50/60 Hz
[V]
CAB6-105-EI…CAB6-250-E ➎
Price Adder for:
Special control voltages
110- 208- 380130 277 400
Type
Available Control Voltages
No Surcharge
100-M
100-C
CAB6-85…CAB6-140 ➍
12…500 V 50 Hz, 12…600 V 60 Hz
12…600 V 50 Hz, 12…600 V 60 Hz
21…550 V 50 Hz, 21…575 V 60 Hz, 110…240 V 50/60 Hz
> 25 pieces
> 20 pieces
> 25 pieces
( ) Control voltages in parentheses: No inventory
➍ 50/60 Hz coil only available for CAB6-85 and 105
➎ Signal voltage of the CAB6...EI electronic interface:
Ue: 24 VDC / Ie: 15 mA
Logical 1: 13.0 VDC…30.2 VDC
Logical 0: -3.0 VDC…+5.0 VDC
Accessories - Site 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
Rockwell Automation
4-11
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
3-pole Contactors
• DC control
• 3 main contacts
4
100-M..Z
100-C..Z
[kW] ➊
230 V
400 / 415 V
[A]
500 V
690 V
230 V
400 / 415 V
500 V
CAB6
Auxiliary
Contacts
Internal
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
AC-1
(40 °C)
[A]
100-C..Z
Cat. No.
PQ
690 V
1
0
100-M05N
⊗ 3 ✪
1
100-M05N
⊗ 31 ✪
0
0
100-M09N
⊗ 3 ✪
1
20
3
4
4
—
12
9
7
—
1
100-M09N
⊗ 31 ✪
0
0
100-M12N
⊗ 3 ✪
1
20
3
5.5 ➋
4
—
12
12 ➋
7
—
0
1
100-M12N
⊗ 31 ✪
0
100-C09
⊕ ⊗ 10 ✫
1
32
3
4
4
4
12
9
7
5
1
100-C09
⊕ ⊗ 01 ✫
0
0
100-C12
⊕ ⊗ 10 ✫
1
32
4
5.5
5.5
5.5
15
12
10
7
1
100-C12
⊕ ⊗ 01 ✫
0
0
100-C16
⊕ ⊗ 10 ✫
1
32
5.5
7.5
7.5
7.5
20
16
14
9
0
1
100-C16
⊕ ⊗ 01 ✫
0
100-C23
⊕ ⊗ 10 ✫
1
32
7.5
11
13
10
26.5
23
20
12
1
100-C23
⊕ ⊗ 01 ✫
0
50
10
15
15
15
35
30
25
18
0
0
100-C30
⊕ ⊗ 00 ✫
100-C37
⊕ ⊗ 00 ✫
50
11
18.5 / 20
20
18.5
38
37
30
21
0
0
100-C43
⊕ ⊗ 00
85
13
22
25
22
44
43
38
25
0
0
100-C60
⊕ ⊗ 00
100
18.5
32
37
32
62
60
55
34
0
0
1
100-C72
⊕ ⊗ 00
100
22
40
45
40
72
72
67
42
0
0
100-C85
⊕ ⊗ 00
100
25
45
55
45
85
85
80
49
0
0
160
25
45
55
80
85
85
85
85
2
2
CAB6-85-L22⊗
2
2
CAB6-105-L22⊗
160
32
55
63
100
105
105
105
105
0
0
CAB6-105-EI-00⊗
1
1
CAB6-105-EI-11⊗
80
110
140
140
115
115
2
2
CAB6-140-L22⊗
250
45
75
0
0
CAB6-140-EI-00⊗
90
132
140
140
140
140
1
1
CAB6-140-EI-11⊗
0
0
CAB6-170-EI-00⊗
250
55
90 / 100
110
160
170
170
170
170
1
1
CAB6-170-EI-11⊗
1
0
0
CAB6-210-EI-00⊗
350
63
110
150
200
210
210
210
210
1
1
CAB6-210-EI-11⊗
0
0
CAB6-250-EI-00⊗
350
80
132 / 150
160
250
250
250
250
250
1
1
CAB6-250-EI-11⊗
0
0
CAB6-300-EI-00⊗
450
90
160
200
300
300
300
300
300
1
1
CAB6-300-EI-11⊗
0
0
CAB6-420-EI-00⊗
500
132
220 / 250
300 ➌ 425 ➌
420
420
420 ➌ 420 ➌
1
1
CAB6-420-EI-11⊗
Bulletin CAB contactors are suitable for use with operating voltages up to 1000V. Bulletin CAB6-...-El contactors are equipped with electronic coil control
20
1.5
2.2
2.2
—
6.5
5.3
4
—
➊ Power ratings: Preferred values according to IEC 60072-1
➋ Value applies only to AC-2 and AC-3
➌ Value applies only to AC-2 and AC-3; AC-4: 360 A
PQ = Package Quantity
Accessories - Site 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
4-12
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
Selection of Options
Options
Cat. No. Suffix
⊕ Coil connection position
⊗ Voltage suffix code
✪ Package quantity 100-M
✫ Package quantity 100-C
Description
No Entry
Ordering Example
Line-side coil connection (above, standard quantity)
U
e.g. ZJ
No Entry
100-C09⊗10
Load-side coil connection (below)
Voltage suffix code from table below
Multi-pack (10 pieces) (Only Z24, ZD24)
100-C09U⊗10
100-C09ZJ10
100-M09N⊗3
S
Single item (1 piece, standard quantity)
No Entry
Single item (1 piece, standard quantity)
100-C09⊗10
Multi-pack (20 pieces)
100-C09⊗10M
M
100-M09N⊗3S
4
Attention:
Bulletin 100-M…S: standard quantity = single item (1 piece)
Bulletin 100-C, CAB6: standard quantity = single item (1 piece)
!
⊗ Voltage Suffix Codes for DC Control
[V]
100-M
DC
with diode protection circuit DC
100-C09…C43
[V]
DC
CAB6-105-EI…CAB6-300-EI
CAB6-420-EI
Price Adder for:
Special control voltages
()
➍
➎
➏
48
110
220
Z24
ZD24
(Z48)
—
Z11
—
(Z2)
[V] 9 ➍
DC
with diode protection circuit DC
100-C60…C85
DC
with diode protection circuit DC
CAB6-85…CAB6-140 ➏
24
[V]
DC
DC
12
24 ➎
(ZR)
—
—
(DR)
(ZQ)
—
—
(DQ)
ZJ
DJ
—
DJ
24
48
110
36
48
60
64
72
80
(ZW) (ZY) (ZZ) (ZB) (ZG) (ZE)
—
—
—
—
—
—
—
—
—
—
—
—
(DW) (DY) (DZ) (DB) (DG) (DE)
110
115
ZD
—
—
DD
(ZP) (ZS) (ZA) (ZF) (ZT)
—
—
—
—
—
—
—
—
—
—
(DP) (DS) (DA) (DF) (DT)
125
220
230
250
220
66
(70)
76
(86)
2428
4872
90135
110135
66
—
(70)
(70)
76
—
—
76
170- 190255 255
(86)
—
—
(86)
Type
Available Control Voltages
No Surcharge
100-M..Z
100-C..Z
CAB6-85…CAB6-140
12…250 VDC
12…250 VDC
24…240 VDC
> 25 pieces
> 20 pieces
> 25 pieces
Control voltages in parentheses: No inventory
Extended operating limits 0.65…1.3 x Us
Extended operating limits 0.7…1.25 x Us
With conventional DC control, the pickup winding must be interconnected with the late-breaking auxiliary contacts
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
Rockwell Automation
4-13
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
Special Versions
• AC / DC control
•
• 4-pole contactors
• Latched contactors
4
100-M
100-C
100-ML
4-pole Contactors Bulletin 100-M, 100-C
Main Poles
(Fitted)
Switching of 3-phase Motors AC-2, AC-3, AC-4 ➊ (60 °C)
AC-1
(40°C)
[kW] ➋
[A]
[A]
230 V
400 / 415 V
500 V
690 V
230 V
400 / 415 V
500 V
690 V
20
3
4
4
—
12
9
7
—
32
7.5
11
13
10
26.5
23
20
12
4
4
3
2
0
0
1
2
Available
Options
Cat. No.
AC/DC
AC/DC
100-M09N
100-C23 ⊕
100-C23 ⊕
AC/DC ➌
100-C23 ⊕
PQ
⊗ 4
⊗ 400
⊗ 300
⊗ 200
✪
✫
✫
✫
(4-pole 100-C09…C16 contactors available upon request)
Latched Contactors Bulletin 100-ML
Auxiliary
Contacts
Latched
Contactors
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
AC-1
(40°C)
[kW]
230 V
400 / 415 V
500 V
690 V
230 V
400 / 415 V
500 V
690 V
20
3
4
4
—
12
9
7
—
Cat. No. Suffix
⊕ Coil connection position
⊗ Tension de commande
✪ Package quantity 100-M
✫ Package quantity 100-C
Cat. No.
PQ
AC
AC
100-ML09N⊗3
100-ML09N⊗31
1
[A]
[A]
Options
Available
Options
No Entry
U
e.g. KJ
No Entry
S
No Entry
M
1
0
0
1
Description
Ordering Example
Line-side coil connection (above, standard quantity)
Load-side coil connection (below)
Voltage suffix code from table below
Multi-pack (10 pieces) (Only KD, D, KF, KK, Z24, ZD24)
Single item (1 piece, standard quantity)
Single item (1 piece, standard quantity)
Multi-pack (20 pieces)
100-C23⊗400
100-C23U⊗400
100-C23KJ400
100-M09N⊗4
100-M09N⊗4S
100-C23⊗400
100-C23⊗400M
➊ AC-4 value only for contact assembly with 3 resp, 4 N.O. contacts
➋ Power ratings: Preferred values according to IEC 60072-1
➌ No inventory
!
Attention:
Bulletin 100-M…S: standard quantity = single item (1 piece)
Bulletin 100-C: standard quantity = single item (1 piece)
PQ = Package Quantity
Accessories - Site 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
4-14
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
⊗ Voltage Suffix Codes for AC Control
100-M
100-C
[V]
24
48
110
110120
230
220230
230240
240
380400
400415
50 Hz
60 Hz
50/60 Hz
—
—
KD
—
—
KH
D
—
—
—
D
—
—
—
KF
(A)
—
—
—
(A)
—
—
—
(KT)
KK
—
—
KK
—
[V]
12
24
32
36
42
48
100
100110
110
120
127
200
200220
200230
208240
50 Hz
60 Hz
50/60 Hz
(R)
(Q)
—
(K)
(J)
KJ
(V)
—
—
(W)
(V)
—
(X)
—
—
(Y)
(X)
KY
(KP)
—
(KP)
—
(KP)
—
(D)
—
KD
(P)
(D)
—
(S)
—
—
(KG) —
— (KG)
(KG) —
—
—
(KL)
—
(L)
—
[V]
220230
230
230240
240
277
347
380
380400
400
400415
440
480
500
550
600
(F)
—
—
—
—
KF
(VA)
—
—
(T)
(A)
(KA)
—
(T)
—
—
(I)
—
—
(E)
—
(N)
—
—
—
—
KN
(G)
—
—
(B)
(N)
(KB)
—
(B)
—
(M)
—
—
(C)
—
—
—
(C)
—
64
72
80
110
115
125
220
230
250
ZD
—
—
DD
(ZP) (ZS)
—
—
—
—
(DP) (DS)
(ZA)
—
—
(DA)
(ZF)
—
—
(DF)
(ZT)
—
—
(DT)
50 Hz
60 Hz
50/60 Hz
⊗ Voltage Suffix Codes for DC Control
100-M
DC
with diode protection circuit DC
100-C09…C43
DC
with diode protection circuit DC
100-C60…C85
DC
with diode protection circuit DC
[V]
110
220
Z24 (Z48) Z11
ZD24 —
—
24
(Z2)
[V] 9 ➍
48
12
(ZR) (ZQ)
—
—
—
—
(DR) (DQ)
24 ➎
ZJ
DJ
—
DJ
36
48
(ZW) (ZY)
—
—
—
—
(DW) (DY)
60
(ZZ)
—
—
(DZ)
(ZB) (ZG) (ZE)
—
—
—
—
—
—
(DB) (DG) (DE)
Price Adder for:
Type
Available Control Voltages
No Surcharge
Special control voltages
100-M
100-C
12…500 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC
> 25 pieces
> 20 pieces
( ) Control voltages in parentheses: No inventory
➍ Extended operating limits 0.65…1.3 x Us
➎ Extended operating limits 0.7…1.25 x Us
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
Rockwell Automation
4-15
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
Reversing Contactors
• 3 main contacts, coil connections above
• Mechanical / Electrical interlock included
• Wiring set for main pole interconnection included
4
AC-1
(40°C)
[kW] ➊
[A]
Auxiliary
Contact
per Contactor
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
Auxiliary
Contact
on Interlock
Cat. No.
PQ
[A]
230 V 400 / 415 V 500 V 690 V 230 V 400 / 415 V 500 V 690 V
20
1.5
2.2
2.2
—
6.5
5.3
4
—
20
3
4
4
—
12
9
7
—
20
3
5.5 ➍
4
—
12
12 ➍
7
—
32
3
4
4
4
12
9
7
5
32
4
5.5
5.5
5.5
15
12
10
7
32
5.5
7.5
7.5
7.5
20
16
14
9
32
7.5
11
13
10
26.5
23
20
12
50
50
85
100
100
100
10
11
13
18.5
22
25
15
18.5 / 20
22
32
40
45
15
20
25
37
45
55
15
18.5
22
32
40
45
35
38
44
62
72
85
30
37
43
60
72
85
25
30
38
55
67
80
18
21
25
34
42
49
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
0
1
1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
0
0
1
1
1
0
0
0
0
0
0
0
0
2
0
2
0
2
0
2
2
2
0
0
0
➋➌
➋
➋➌
➋
➋➌
➋
➎
➎
➎
104-M05N
104-M05N
104-M09N
104-M09N
104-M12N
104-M12N
104-C09
104-C09
104-C12
104-C12
104-C16
104-C16
104-C23
104-C23
104-C30
104-C37
104-C43
104-C60
104-C72
104-C85
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
3
31
3
31
3
31
10
00
10
00
10
00
10
00
00
00
00
10
10
10
Bulletin CAB contactors are suitable for use with operating voltages up to 1000V. Bulletin CAB6-...-El contactors are equipped with electronic coil control
160
25
45
55
80
85
85
85
85
1
1
0
CAU ✤ B6-85CAU ✤ B6-105160
32
55
63
100
105
105
105
105
1
1
0
CAU ✤ B6-105-EI80
110
140
140
115
115
1
1
0
CAU ✤ B6-140250
45
75
CAU ✤ B6-140-EI90
132
140
140
140
140
1
1
0
250
55
90 / 100
110
160
170
170
170
170
1
1
0
CAU ✤ B6-170-EICAU ✤ B6-210-EI350
63
110 / 125
150
200
210
210
210
210
1
1
0
350
80
132 / 150
160
250
250
250
250
250
1
1
0
CAU ✤ B6-250-EICAU ✤ B6-300-EI450
90
160
200
300
300
300
300
300
1
1
0
CAU ✤ B6-420-EI500
132
220 / 250 300 ➏ 425 ➏ 420
420
420 ➏ 420➏
1
1
0
Options
◆ Mechanical interlock
✤ Mechanical interlock
⊗ Voltage suffix code
Cat. No. Suffix
No Entry
-X
No Entry
M
e.g. KJ
Description
10
10
10
10
10
10
10
10
10
10
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
⊗
1
1
1
Ordering Example
with mechanical interlock (standard)
without mechanical interlock
without mechanical interlock (standard)
with mechanical interlock
Voltage suffix code from the table on the next page
➊ Power ratings: Preferred values according to IEC 60072-1
➋ DC-control only available without mechanical interlock
➌ For electronic interlock additional N.C. contacts required
-E
-E
-E
-E
-E
-E
-E
-E
-E
-E
-E
-E
-E
-E
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
104-M05N⊗3
104-M05N⊗3-X
CAU-B6-105-EI-10⊗
CAUMB6-105-EI-10⊗
104-M05NKJ3
➍ Value applies only to AC-2 and AC-3
➎ Bulletin 100-MCA00 mechanical interlock. Electrical interlock via the
front mounted auxiliary contact block (2 pole)
➏ Value applies only to AC-2 and AC-3; AC-4: 360 A
PQ = Package Quantity
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
4-16
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
⊗ Voltage Suffix Codes for AC Control
[V]
104-M
50 Hz
60 Hz
50/60 Hz
[V]
24
48
110
—
—
KD
—
—
KH
D
—
—
12
24
32
(R)
(Q)
—
220[V]
230
(F)
50 Hz
—
60 Hz
50/60 Hz —
50 Hz
60 Hz
50/60 Hz
104-C
[V]
CAUB6-85…CAUB6-140 ➐
CAUB6-300-EI…CAUB6-420-EI
(V)
—
—
230230
240
— (VA)
—
—
KF —
24
28
05
—
—
24[V]
28
50/60 Hz 05
50/60 Hz —
50 Hz
60 Hz
50/60 Hz
CAUB6-105-EI…CAUB6-250-EI
(K)
(J)
KJ
48
—
08
05
—
—
—
43- 11065 130
08 10
08 10
110220- 230230
240
120
230 240
—
—
(A)
—
—
D
—
—
(A)
—
—
KF
—
— (KT)
10036
42
48 100
110
(W) (X) (Y) (KP) —
(V)
—
(X)
— (KP)
—
—
KY (KP) —
380240 277 347 380
400
(T)
—
—
—
(N)
(A) (T)
(I)
(E)
—
(KA) —
—
—
—
22055 110 127
230
230
—
10
—
13
—
08
—
10
—
—
— (48) —
—
54
208- 380277 400
14
16
14
16
380- 400400 415
KK
— KK
—
—
110
(D)
—
KD
120
127
200- 200208208
220 230
240
(KG) —
—
—
—
— (KG) — (H) (L)
(KG) — (KL) —
—
200
(P) (S)
(D)
—
—
—
400400
440 480 500 550 600
415
— (G) (B)
—
(M) (C) —
—
—
(N) (B)
—
— (C)
KN — (KB) —
—
—
—
380440240 260 277
415
480
400
460
(15) —
—
16 (17) —
—
—
13 (15) —
—
16 (17)
(55) —
—
—
—
—
—
⊗ Voltage Suffix Codes for DC Control
104-M
[V]
24
Z24
DC
ZD24
with diode protection circuit DC
[V] 9 ➑
104-C09…C43
DC
(ZR)
—
with diode protection circuit DC
104-C60…C85
DC
—
(DR)
with diode protection circuit DC
[V] 24
CAB6-85…CAB6-140
DC
66
24[V]
CAB6-105-EI…CAB6-300-EI
28
66
DC
—
CAB6-420-EI
DC
Price Adder for:
Special control voltages
48
Type
104-M
104-C
CAUB6-85…CAUB6-140 ➐
()
E
➐
➑
➒
110
220
(Z48) Z11 (Z2)
—
—
12
24 ➒ 36
48
60
64
72
80 110 115 125 220 230 250
(ZQ)
ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE) ZD (ZP) (ZS) (ZA) (ZF) (ZT)
—
DJ
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
(DQ) DJ (DW) (DY) (DZ) (DB) (DG) (DE) DD (DP) (DS) (DA) (DF) (DT)
48
110 220
(70)
76
(86)
4890- 110- 170- 19072
135 135 255 255
(70)
76
—
(86) —
(70)
—
76
— (86)
Available Control Voltages
12…500 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC
21…550 V 50 Hz, 21…575 V 60 Hz, 110…240 V 50/60 Hz,
24…240 VDC
No Surcharge
> 25 pieces
> 20 pieces
> 25 pieces
Control voltages in parentheses: No inventory
Wiring per IEC standard
50/60 Hz coils for CAB6-140 contactor not available
Extended operating limits 0.65…1.3 x Us
Extended operating limits 0.7…1.25 x Us
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
Rockwell Automation
4-17
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
Safety Contactors
•
•
•
•
•
•
4
AC / DC control
3 / 4 main contacts
Positively guided contacts according to IEC 947-5-1
Mechanically coupled Contactor and Auxiliary contact block
Protection against unintended actuation
Auxiliary contacts are electronically compatible according to
DIN 19240
With 3 Main Contacts
AC-1
(40°C)
Positively Guided
Auxiliary Contacts
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
[kW] ➊
[A]
[A]
230 V
400 / 415 V
500 V
690 V
230 V
400 / 415 V
500 V
690 V
32
3
4
4
4
11.5
9
7
5
32
4
5.5
5.5
5.5
14.5
12
10
7
32
5.5
7.5
7.5
7.5
20
16 / 15
13
9.3
32
7.5
11
11
10
24
23 / 22
18
12
50
10
15
15
15
34
30 / 29
24
17
50
11
18.5
18.5
18.5
37
37 / 36
30
20
85
13
22
22
22
42
43 / 41
34
25
100
18.5
30
30
30
62
60 / 58
45
34
100
22
37
37
37
70
72 / 69
56
42
100
25
45
45
45
85
85 / 82
67
49
0
1
2
0
1
2
0
1
2
0
1
2
0
2
0
2
0
2
0
2
0
2
0
2
5
4
3
5
4
3
5
4
3
5
4
3
4
2
4
2
4
2
4
2
4
2
4
2
Cat. No.
PQ
100S-C09⊗05C
100S-C09⊗14C
100S-C09⊗23C
100S-C12⊗05C
100S-C12⊗14C
100S-C12⊗23C
100S-C16⊗05C
100S-C16⊗14C
100S-C16⊗23C
100S-C23⊗05C
100S-C23⊗14C
100S-C23⊗23C
100S-C30⊗04C
100S-C30⊗22C
100S-C37⊗04C
100S-C37⊗22C
100S-C43⊗04C
100S-C43⊗22C
100S-C60⊗04C
100S-C60⊗22C
100S-C72⊗04C
100S-C72⊗22C
100S-C85⊗04C
100S-C85⊗22C
1
Cat. No.
PQ
100S-C23⊗404C
100S-C23⊗304C
100S-C23⊗422C
100S-C23⊗322C
1
With 4 Main Contacts
[A]
32
Positively Guided
Auxiliary Contacts
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
AC-1
(40°C)
[kW] ➊
230 V
400 / 415 V
7.5
11
[A]
500 V
11
690 V
10
230 V
24
400 / 415 V
23 / 22
500 V
18
690 V
12
0
0
2
2
4
4
2
2
PQ = Package Quantity
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
4-18
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Product Selection
Reversing-Safety Contactors
•
•
•
•
•
•
•
•
•
AC / DC control
3 main contacts, coil connections above
Positively guided contacts acc. to IEC 947-5-1
Mechanically coupled Contactor and Auxiliary contact block
Protection against unintended actuation
Auxiliary contacts are electronically compatible according
to DIN 19240
Mechanical / Electrical interlock included
Wiring set for main pole interconnection included
4
With 3 Main Contacts
AC-1
(40°C)
Positively Guided
Aux. contact per Contactor
Switching of 3-phase Motors AC-2, AC-3, AC-4 (60 °C)
[kW] ➊
Cat. No.
PQ
104S-C09⊗012C
104S-C09⊗010C
104S-C12⊗012C
104S-C12⊗010C
104S-C16⊗012C
104S-C16⊗010C
104S-C23⊗012C
104S-C23⊗010C
104S-C30⊗010C
104S-C30⊗008C
104S-C37⊗010C
104S-C37⊗008C
104S-C43⊗010C
104S-C43⊗008C
104S-C60⊗010C
104S-C60⊗008C
104S-C72⊗010C
104S-C72⊗008C
104S-C85⊗010C
104S-C85⊗008C
1
[A]
[A]
230 V
400 / 415 V
500 V
690 V
230 V 400 / 415 V 500 V
690 V
32
3
4
4
4
11.5
9
7
5
32
4
5.5
5.5
5.5
14.5
12
10
7
32
5.5
7.5
7.5
7.5
20
16 / 15
13
9.3
32
7.5
11
11
10
24
23 / 22
18
12
50
10
15
15
15
34
30 / 29
24
17
50
11
18.5
18.5
18.5
37
37 / 36
30
20
85
13
22
22
22
42
43 / 41
34
25
100
18.5
30
30
30
62
60 / 58
45
34
100
22
37
37
37
70
72 / 69
56
42
100
25
45
45
45
85
85 / 82
67
49
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
5
5
5
5
5
5
5
5
4
4
4
4
4
4
4
4
4
4
4
4
➋
➋
➋
➋
➋
➋
➋
➋
➋
➋
⊗ Voltage Suffix Codes for AC Control
[V]
100S-C. 104S-C
12
50 Hz
60 Hz
50/60 Hz
(R)
(Q)
—
220[V]
230
50 Hz
(F)
60 Hz
—
50/60 Hz —
24
(K)
(J)
KJ
230
—
—
KF
32
36
(V) (W)
—
(V)
—
—
230240
240
(VA) (T)
—
(A)
— (KA)
42
48
(X)
—
—
(Y)
(X)
KY
277
347
—
(T)
—
—
(I)
—
100110
(KP) —
— (KP)
(KP) —
380380
400
—
(N)
(E)
—
—
—
100
110
120
(D)
—
KD
(P)
(S)
(D)
—
—
—
400440
415
(G)
(B)
—
(N)
— (KB)
400
—
—
KN
127
200- 200- 208220 230 240
(KG) —
—
—
— (KG) —
(L)
(KG) — (KL) —
200
480
500
550
600
—
(B)
—
(M)
—
—
(C)
—
—
—
(C)
—
⊗ Voltage Suffix Codes for DC Control
100S-C09…C43, 104S-C09…C43
DC
with diode protection circuit DC
100S-C60…C85, 104S-C60…C85 DC
with diode protection circuit DC
Price Adder for:
Special control voltages
[V] 9 ➌
12 24 ➍ 36
48
60
64
72
80
(ZR) (ZQ) ZJ (ZW) (ZY) (ZZ) (ZB) (ZG) (ZE)
—
—
DJ
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
(DR) (DQ) DJ (DW) (DY) (DZ) (DB) (DG) (DE)
Type
100S-C. 104S-C
110
ZD
—
—
DD
115 125 220 230 250
(ZP) (ZS) (ZA) (ZF) (ZT)
—
—
—
—
—
—
—
—
—
—
(DP) (DS) (DA) (DF) (DT)
Available Control Voltages
12…600 V 50 Hz, 12…600 V 60 Hz, 12…250 VDC
No Surcharge
> 20 pieces
( ) Control voltages in parentheses: No inventory
➊ Power ratings: Preferred values according to IEC 60072-1
➋ With mechanical and electrical locking 100-MCA02
➌ Extended operating limits 0.65…1.3 x Us
➍ Extended operating limits 0.7…1.25 x Us
Accessories - Page 4-24
Specifications - Page 4-36
Dimensions - Page 4-61
Rockwell Automation
4-19
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Assignment of Contacts
Contactors with 3 Main Contacts
4
51 61 71 81
51 61 71 81
53 61 71 83
52 62 72 82
52 62 72 82
54 62 72 84
1
3
5
21
2
4
6
22
100S-C09⊗05C…C23⊗05C
1
3
5
13
2
4
6
14
100S-C09⊗14C…C23⊗14C
11 21 31 41
13 21 31 43
12 22 32 42
14 22 32 44
1
3
5
1
3
5
2
4
6
2
4
6
100S-C30⊗04C…C85⊗04C
1
3
5
21
2
4
6
22
100S-C09⊗23C…C23⊗23C
100S-C30⊗22C…C85⊗22C
Contactors with 4 Main Contacts
11 21 31 41
11 21 31 41
12 22 32 42
12 22 32 42
1
2
3
5
7
1
4
6
8
2
100S-C23⊗404C
3
5
R1
4
6
R2
100S-C23⊗304C
13 21 31 43
13 21 31 43
14 22 32 44
14 22 32 44
1
3
5
7
1
3
5
R1
2
4
6
8
2
4
6
R2
100S-C23⊗422C
100S-C23⊗322C
Product Selection - Page 4-10
4-20
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Assignment of Contacts
Reversing-Safety Contactors with 3 Main Contacts
51 61 71 81
21
51 61 71 81
51 61 71 81
51 61 71 81
52 62 72 82
22
52 62 72 82
52 62 72 82
52 62 72 82
1
3
5
21
21
1
3
5
21
1
3
5
21
1
3
5
21
2
4
6
22
22
2
4
6
22
2
4
6
22
2
4
6
22
104S-C09⊗012C…C23⊗012C
4
104S-C09⊗010C…C23⊗010C
51 61 71 81
21
51 61 71 81
51 61 71 81
51 61 71 81
52 62 72 82
22
52 62 72 82
52 62 72 82
52 62 72 82
1
3
5
21
1
3
5
1
3
5
1
3
5
2
4
6
22
2
4
6
2
4
6
2
4
6
104S-C30⊗010C…C85⊗010C
104S-C30⊗008C…C85⊗008C
Product Selection - Page 4-10
Rockwell Automation
4-21
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Assignment of Contacts
Device Combinations in Accordance with EN Standards
Auxiliary Contact Blocks
Contactors 100-C (AC / DC Control)
Circuit Diagram Control
100-C09⊕⊗10
100-C12⊕⊗10
100-C16⊕⊗10
100-C23⊕⊗10
A1
1
3
5
13
K1
A1
1
3
5
2
4
6
14
100-C30⊕⊗00
100-C37⊕⊗00
100-C43⊕⊗00
100-C60⊕⊗00
100-C72⊕⊗00
100-C85⊕⊗00
A1
21
1
3
A2
2
4
6
22
100-C23⊕⊗400
5
K1
K1
A2
A1
1
3
5
2
4
6
A1
7
K1
A2
100-C23⊕⊗300
1
3
5
R1
K1
A2
2
4
6
8
100-C23⊕⊗200
A1
1
R1 R3 3
A2
2
R2 R4 4
K1
A2
2
4
6
R2
Front-mounted ➊
51 61
100-FA02
AC / DC
10 + 02 = 12
01 + 02 = 03
00 + 02 = 02
00 + 02 = 02
00 + 02 = 02
00 + 02 = 02
AC / DC
10 + 11 = 21
01 + 11 = 12
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
AC / DC
—
—
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
AC / DC
10 + 11 = 21
01 + 11 = 12
—
—
—
—
AC / DC
10 + 20 = 30
01 + 20 = 21
00 + 20 = 20
00 + 20 = 20
00 + 20 = 20
00 + 20 = 20
—
—
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
AC / DC
10 + 22 = 32
01 + 22 = 23
00 + 22 = 22
00 + 22 = 22
00 + 22 = 22
00 + 22 = 22
AC / DC
—
—
00 + 22 = 22
00 + 22 = 22
00 + 22 = 22
00 + 22 = 22
AC / DC
10 + 22 = 32
—
—
—
—
—
AC / DC
10 + 31 = 41
01 + 31 = 32
00 + 31 = 31
00 + 31 = 31
00 + 31 = 31
00 + 31 = 31
AC / DC
10 + 40 = 50
01 + 40 = 41
00 + 40 = 40
00 + 40 = 40
00 + 40 = 40
00 + 40 = 40
➋ AC / DC
10 + 22 = 32
01 + 22 = 23
00 + 22 = 22
00 + 22 = 22
00 + 22 = 22
00 + 22 = 22
AC / DC
10 + 01 = 11
01 + 01 = 02 ➌
00 + 01 = 01
00 + 01 = 01
00 + 01 = 01
00 + 01 = 01
AC / DC
10 + 10 = 20 ➌
01 + 10 = 11
00 + 10 = 10
00 + 10 = 10
00 + 10 = 10
00 + 10 = 10
AC / DC
10 + 02 = 12 ➌
—
00 + 02 = 02
00 + 02 = 02
00 + 02 = 02
00 + 02 = 02
AC / DC
10 + 11 = 21 ➌
01 + 11 = 12 ➌
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
AC / DC
10 + 20 = 30 ➌
01 + 20 = 21 ➌
00 + 20 = 20
00 + 20 = 20
00 + 20 = 20
00 + 20 = 20
➋ AC / DC
10 + 11 = 21 ➌
01 + 11 = 12 ➌
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
00 + 11 = 11
52 62
53 61
100-FA11
54 62
13 21
100-FB11
14 22
23 31
100-FC11
24 32
53 63
100-FA20
54 64
17 25
➋ AC / DC
100-FBL11
18 26
53 61 71 83
100-FA22
54 62 72 84
13 21 31 43
100-FB22
14 22 32 44
21 31 43 53
100-FC22
22 32 44 54
53 61 73 83
100-FA31
54 62 74 84
53 63 73 83
100-FA40
54 64 74 84
53 61 75 87
100-FAL22
54 62 76 88
Side-mounted ➊
21
32
100-SB01
22
31
13
44
100-SB10
14
43
11 21
32 42
100-SB02
12 22
31 41
13 21
32 44
100-SB11
14 22
31 43
13 23
34 44
100-SB20
14 24
33 43
17 25
36 48
100-SBL11
18 26
35 47
4
100-C09⊕⊗01
100-C12⊕⊗01
100-C16⊕⊗01
100-C23⊕⊗01
Product Selection - Page 4-10
4-22
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Assignment of Contacts
Device Combinations in Accordance with EN Standards
Auxiliary Contact Block
Circuit Diagram
Control
Miniature Contactor 100-M (AC / DC Control)
100-M05N⊗31
100-M09N⊗4
100-M09N⊗31
100-M12N⊗31
100-M05N⊗3
100-M09N⊗3
100-M12N⊗3
A1
1
3
5
13
A2
2
4
6
14
K1
A1
1
3
5
7
K1
A1
1
3
5
21
A2
2
4
6
22
K1
A2
2
4
6
8
Front-mounted
21 31
195-MB02
AC / DC
10 + 02 = 12
40 + 02 = 42
—
AC / DC
10 + 11 = 21
40 + 11 = 51
—
AC / DC
10 + 20 = 30
40 + 20 = 60
01 + 20 = 21
AC / DC
10 + 22 = 32
40 + 22 = 62
—
AC / DC
10 + 40 = 50
40 + 40 = 80
01 + 40 = 41
4
22 32
21 33
195-MB11
22 34
53 63
195-MA20
54 64
43 53 21 31
195-MB22
44 54 22 32
53 63 73 83
195-MA40
54 64 74 84
Auxiliary Contact Block
Circuit
Diagram
Contactors CAB6 (AC / DC Control)
Control
CAB6-85-00⊗
CAB6-105-00⊗
CAB6-140-00⊗
A1
1
3
5
A2
2
4
6
K1
CAB6-85-11⊗
CAB6-105-11⊗
CAB6-140-11⊗
A1
1
3
5
13 21
A2
2
4
6
14 22
CAB6-85-L11⊗
CAB6-105-L11⊗
CAB6-140-L11⊗
A1
B1 1
3
5
43 35
4
6
44 36
K1
K1
CAB6-85-L22⊗
CAB6-105-L22⊗
CAB6-140-L22⊗
A1
B1 1
3
5
13 21
43 35
4
6
14 22
44 36
K1
A2
2
CAB6-140-EI-00⊗
CAB6-170-EI-00⊗
CAB6-210-EI-00⊗
CAB6-250-EI-00⊗
CAB6-300-EI-00⊗
CAB6-420-EI-00⊗
A1
1
3
5
A2
2
4
6
K1
A2
2
CAB6-140-EI-11⊗
CAB6-170-EI-11⊗
CAB6-210-EI-11⊗
CAB6-250-EI-11⊗
CAB6-300-EI-11⊗
CAB6-420-EI-11⊗
A1
1
3
5
13 21
A2
2
4
6
14 22
K1
Right-side mounted
43 31
CAB6-P2-11
44 32
83 71
CAB6-P4-11
84 72
43 35
CAB6-P2-L11
44 36
31
CAB6-P2-B11
32 34
AC
DC
AC / DC
AC
DC
AC / DC
AC
➋
DC
AC / DC
AC
➍
DC
AC / DC
00 + 11 = 11
—
—
00 + 11 = 11
—
—
00+ 11 = 11
—
—
00+ 11 =11
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
—
11+ 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
22 + 11 = 33
—
—
22 + 11 = 33
—
—
22 + 11 = 33
—
—
22 + 11 = 33
—
—
—
00 + 11 = 11
—
—
00 + 11 = 11
—
—
00 + 11 = 11
—
—
00 + 11 = 11
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = L22
—
—
11 + 11 = 22
AC
DC
AC / DC
AC
DC
AC / DC
AC
➍
DC
AC / DC
00 + 11 = 11
—
—
00 + 11 = 11
—
—
00 + 11 = 11
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
22 + 11 = 33
—
—
22 + 11 = 33
—
—
22 + 11 = 33
—
—
—
00 + 11 = 11
—
—
00 + 11 = 11
—
—
00+ 11 = 11
—
—
11 + 11 = 22
—
—
11 + 11 = 22
—
—
11 + 11 = 22
Left-side mounted
13 21
CAB6-P1-11
14 22
53 61
CAB6-P3-11
54 62
61
CAB6-P3-B11
62 64
➊ Up to 8 auxiliary contacts possible: Contactor + Front-mounted (AC max. 4 N.C:/DC max. 4 N.C.), Side-mounted
(AC max. 2 N.O./DC max. 2 N.O. and max. 2 N.C.)
➋ Early make and/or late break
➌ Double numbering: Because of double numbering only left-side mounting is recommended
➍ Electronically suited auxiliary contact block
Product Selection - Page 4-10
Rockwell Automation
4-23
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules: Auxiliary Contact Blocks
Description
Circuit Diagram
For Use with
Cat. No.
PQ
100-M…3
195-MB02
100-M
195-MB11
100-M
195-MA20
100-M…3,
100-M…4
195-MB22
100-M
195-MA40
100-C
100-FA02
✫
100-C
100-FA11
✫
C30⊗00…C85⊗00
100-FB11
✫
C09⊗10…C23⊗10
100-FC11
✫
100-C
100-FA20
✫
C30⊗00…C85⊗00
100-FBL11
✫
100-C
100-FA22
✫
C09⊗10…C23⊗10
100-FC22
✫
C30⊗00…C85⊗00
100-FB22
✫
100-C
100-FA31
✫
100-C
100-FA40
✫
100-C
100-FAL22
✫
21 31
22 32
21 33
Auxiliary Contact Blocks for Front Mounting
• 2- and 4-pole
• Simple and quick attachment - no tools needed
• Electronically compatible H-contacts
• Contacts themselves in auxiliary contact block
positively guided
• Types with the same functions with several connection
numbering variants
4
22 34
53 63
10
54 64
43 53 21 31
44 54 22 32
53 63 73 83
54 64 74 84
51 61
52 62
53 61
54 62
13 21
14 22
23 31
24 32
53 63
Auxiliary Contact Blocks for Front Mounting ➊
• 2- and 4-pole
• Simple and quick attachment - no tools needed
• Electronically compatible contacts
• Positive guidance in auxiliary and with main contactor
poles (excluding type L)
• Types with the same functions with several connection
numbering variants
L = Early Make/Late Break
54 64
17 25
18 26
53 61 71 83
54 62 72 84
21 31 43 53
22 32 44 54
13 21 31 43
14 22 32 44
53 61 73 83
54 62 74 84
53 63 73 83
54 64 74 84
53 61 75 87
54 62 76 88
PQ = Package Quantity
Product Selection - Page 4-10
4-24
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules: Auxiliary Contact Blocks
Circuit
Diagram
Description
For Use with
Cat. No.
PQ
100-C
100-SB01
✫
100-C,
100S-C ➋
100-SB10
✫
100-C ➋
100-SB02
✫
100-C ➋
100-SB11
✫
100-C,
100S-C ➋
100-SB20
✫
100-C ➋
100-SBL11
✫
CAB6
Left-side
mounting
CAB6-P1-11
CAB6
Right-side
mounting
CAB6-P2-11
CAB6
Left-side
mounting
CAB6-P3-11
CAB6
Right-side
mounting
CAB6-P4-11
CAB6
Right-side
mounting
CAB6-P2-L11
CAB6
Right-side
mounting
CAB6-P2-B11
CAB6
Left-side
mounting
CAB6-P3-B11
21
32
22
31
13
44
14
4
43
11 21
32 42
12 22
31 41
13 21
32 44
14 22
31 43
Auxiliary Contact Blocks for Side Mounting ➊
• 1- and 2-pole
• Dual numbering for left- or right-side mounting on contactor
• Simple and quick attachment - no tools needed
• Electronically compatible contacts
• Positive guidance in auxiliary and with main contactor poles
(excluding type L)
L = Early Make/Late Break
13 23
34 44
14 24
33 43
17 25
36 48
18 26
35 47
13 21
14 22
43 31
Auxiliary Contact Blocks
• Up to 4 auxiliary contact blocks per contactor: P1 and P3
left, P2 and P4 right
• With mechanical interlock — 2 auxiliary contact blocks per
contactor, 1 left and 1 right
• No change of base dimensions with 1 auxiliary contact
block on each side
44 32
53 61
54 62
83 71
84 72
43 35
44 36
•
Electronically compatible auxiliary contacts
AC-1
250 V
0.1 A
31
32 34
61
AC-15, DC-13
Options
✫ Package quantity
Cat. No. Suffix
No Entry
M
3 … 125 V
1 … 100 mA
62 64
Description
10
Ordering Example
Single pack (1 piece, standard quantity)
100-SB10.
Multi-pack (10 pieces)
100-SB10M
➊ Up to 8 auxiliary contacts possible: Contactor + Front-mounted (AC max. 4 N.C:/DC max. 4 N.C.), Side-mounted
(AC max. 2 N.O./DC max. 2 N.O. and max. 2 N.C.)
➋ Double numbering: Because of double numbering 100-C09 … 100-C23 only left-side mounting is recommended
PQ = Package Quantity
Product Selection - Page 4-10
Rockwell Automation
4-25
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules: Timer
Description
Electronic Star-Delta Timing Relay
Output Y picks up when the supply voltage is applied and resets again after time t.
After a fixed changeover time tu output relay ∆ picks up and remains energised until
the supply voltage is interrupted.
Circuit Diagram ✪ Single Selectable Timing Range
Use the catalogue
• 22.5 mm width
number with the appropriate code.
Supply Voltage (A1/A2)
Timing range ✪
U23
24…48 VDC
C
0.5…10 s
24…240 VAC, 50/60 Hz
A1/A2 D
U
1.5…30 s
A40
346…440 VAC, 50/60 Hz
0.05…1 min
t
17/18 E
F
0.15…3 min
17/28
tu=50...65 ms
G
0.5…10 min
4
For Use with
Cat. No.
PQ
100-M, 100-C,
CAB6
700-FSY2✪U23
on request:
700-FSY2✪A40
1
100-M, 100-C,
CAB6
700-FEY2QU23
1
100-M with
110…250 V
50/60 Hz /
110…250 VDC
196-MT3S
196-MT30S
100-M with
110…120 V
50/60 Hz
196-MTSDA1
LED
L
•
A1
17
A2
18
17.5 mm width
Supply Voltage (A1/A2)
U23
24…48 VDC
24…240 VAC, 50/60 Hz
N
28
Multiple Adjustable Timing Ranges
0.15 s…10 min
(3s)
0.15…3 s
(10s) 0.5…10 s
(1mn) 0.05…1 min
(10mn) 0.5…10 min
~
S1
O/I
1
Timer
After the set time has elapsed, the timer
operates and the contactor in series is
energised.
Pick-up Delay
1…3 s
1…30 s
2
10
K1
N
Setting Time
Y Contactor
1…30 s
~
Timer for Y-∆ Switching
After the set time has elapsed, the K3
contactor (Y) is de-energised and then
after a time of 90 ± 30 ms the K2 contactor (∆) is energised.
S1
O/I
1
K2
∆
2
Y
K3
Y
K1
N
K2
∆
K2
∆
K3
Y
67 55
Pneumatic Timer
Pneumatic timing contacts switch after
the set time; the contacts on the main
contactor operate without delay.
• Continuous adjustment range
1…30 s
∆
68 56
1…30 s
Pick-up Delay
0.3…30 s
1.8…180 s
100-M with
220…250 V
50/60 Hz
100-M with
48 V
50/60 Hz
100-C with
AC control
196-MTSDA2
10
196-MTSDA3
100-FPTA30
100-FPTA180
1
65
57
66
58
Drop-out Delay
0.3…30 s
1.8…180 s
All 100-C
100-FPTB30
100-FPTB180
PQ = Package Quantity
Product Selection - Page 4-10
4-26
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules: Timer
Description
Circuit Diagram
L
S
Electronic Timing Modules
Delay of the contactor magnetic coil
• Continuous adjustment range
• High repeat accuracy
A1
For Use with
Cat. No.
100-C with
110…240 V 50/60 Hz
110…250 VDC
100-ETA3
100-ETA30
100-ETA180
PQ
100-C with
24…48 VDC
100-ETAZJ3
100-ETAZJ30
100-ETAZJ180
Pick-up Delay
0.1…3 s
1…30 s
10…180 s
A1
K1M
A2
N
100-ETA
The contact closes after the delay time
elapses.
L
A1
1
4
t
A1 (K1M)
L
S
A1
100-ETB
After interruption of the control signal, the
contactor is switched off after the delay time
elapses.
B2
Drop-out
Delay
A1
K1M
A2
0.3…3 s
1…30 s
10…180 s
N
L
B2
t
100-C09…C37 with
24 V 50/60 Hz
100-ETBKJ3
100-ETBKJ30
100-ETBKJ180
100-C with
110…240 V 50/60 Hz
100-ETB3
100-ETB30
100-ETB180
100-C with
110…240 V 50/60 Hz
100-ETY30
1
A1 (K1M)
L
S
100-ETY
After the set Y time elapses the K3 contact
(Y) switches off and the K2 Contactor (∆)
switches on (Switching delay ∆t 90 ms).
D1
Y1
D
Y
A1
H
A2
N
L
H A1
Y A1
D
A1
Y
A2
A1
Setting Time
Y Contactor
A2
1
1…30 s
∆t
t
D A1
PQ = Package Quantity
Product Selection - Page 4-10
Rockwell Automation
4-27
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules: Mechanical Interlocks
Description
Circuit Diagram
Mechanical Interlock
• For interlocking of two adjacent contactors
• Without additional space requirement attachable
from rear and recessed in top hat rail
Mechanical Interlock
• For interlocking of two adjacent contactors
• Mechanical and electrical interlock in one module
possible by means of integrated auxiliary contacts
• Contactors with AC control: 100-C09…100-C85 and •
Contactors with DC control: 100-C60…100-C85 can
be interlocked any way desired
Attention:
Contactors with DC-control: 100-C09…100-C43 can
only be interlocked with contactors of the same type!
4
•
•
9 mm connection piece included
✫ Package quantity
Cat. No. Suffix
No Entry
M
Cat. No.
PQ
100-M with
AC control
199-MXM1
10
100-C
100-MCA00
✫
100-C
100-MCA02
✫
CAB6
CMB6
10
without auxiliary
contacts
21
21
22
22
with 2 N.C. auxiliary
contacts
Mechanical Interlock
• For interlocking of two adjacent contactors
• One component for the interlock of all Bulletin CAB6
contactors
• For mounting between two contactors; no additional
space required
Options
For Use with
Description
Ordering Example
Single pack (1 piece, standard)
100-MCA00
Multi-pack (10 pieces)
100-MCA00M
PQ = Package Quantity
Product Selection - Page 4-10
4-28
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules
Description
Circuit Diagram
For Use with
Cat. No.
PQ
100-C with
AC control
100-FL11⊗
1
L1~/L+
0
Mechanical Latch
In latching contactors, the contactor coil
is immediately switched off after the
contact on the latch closes (65-66); consequently, no holding current flows. Can
be used for both AC and DC operation
• Auxiliary contacts 1 N.O. + 1 N.C.
I
57 65
K1M
58 66
14
A1
E1
K1M
N~/L-
Interface (electronic)
Interface between the DC control signal
(PLC) and the contactor AC operating
mechanism.
• Control voltage 18…30 VDC
(10…15 mA)
• For coil voltages of 110…240 VAC
• Suitable for all Bulletin 100-C
contactors
• Switching capacity 200 VA
• Requires no overvoltage protection
for the coils
Cat. No. Suffix
⊗ Voltage suffix code
✫ Package quantity
A2
K1R
4
E2
Input
L
Output
A1 E2 E1
100-JE
✫
100-JE12
✫
100-JE48
✫
24 VDC
A1
110 …
12 VDC
240 VAC
K1M
A2
N
100-C,
100S-C
with
AC control
48 VDC
L
E1
A1 (K1M)
120 V AC, 2 inputs
1 relay output
24 V DC, 2 inputs
1 relay output
24 V DC, 2 inputs
1 transistor output
120 V AC, 4 inputs
2 relay outputs
24 V DC, 4 inputs
2 relay outputs
DeviceNet System Accessory Module
• Includes complete terminal connector
set
• Screw- or snap-on mounting to 35
mm DIN Rail EN 50 022
• For product information, see chapter
15 (description, specifications and
dimensions)
Options
13
K1R
100-DNY21R
100-DNY22R
100-DNY22S
1
100-DNY41R
100-DNY42R
24 V DC, 4 inputs
2 transistor outputs
100-DNY42S
Description
Ordering Example
e.g. KJ
No Entry
Voltage suffix code from table below
Single pack (1 piece, standard)
100-FL11KJ
100-JE
M
Multi-pack (10 pieces)
100-JEM
⊗ Voltage Suffix Code for AC Control
[V]
100-FL11
50 Hz
60 Hz
50/60 Hz
[V]
50 Hz
60 Hz
50/60 Hz
Price Adder for:
Special control voltages
12
24
32
36
42
48
100
100110
110
120
127
200
200220
200230
208240
(R)
(Q)
—
(K)
(J)
KJ
(V)
—
—
(W)
(V)
—
(X)
—
—
(Y)
(X)
KY
(KP)
—
(KP)
—
(KP)
—
(D)
—
KD
(P)
(D)
—
(S)
—
—
(KG)
—
(KG)
—
(KG)
—
—
—
(KL)
—
(L)
—
220230
230
230240
240
277
347
380
380400
400
400415
440
480
500
550
600
(F)
—
—
—
—
KF
(VA)
—
—
(T)
(A)
(KA)
—
(T)
—
—
(I)
—
—
(E)
—
(N)
—
—
—
—
KN
(G)
—
—
(B)
(N)
(KB)
—
(B)
—
(M)
—
—
(C)
—
—
—
(C)
—
Type
Available Control Voltages
No Surcharge
100-FL11
12…500 V 50 Hz / 12…600 V 60 Hz
> 20 pieces
( ) Control voltages in parentheses: No inventory
PQ = Package Quantity
Product Selection - Page 4-10
Rockwell Automation
4-29
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Modules: Suppressor Modules
Description
Suppressor Module for 100-M05
/ M09/M12 Contactors
For limiting surge voltage when
coil circuits are interrupted.
4
Circuit
Diagram
For Use with
RC Module
AC control
24…48 VAC
110…240 VAC
24…48 VAC
110…280 VAC
380…480 VAC
Diode Circuit
DC control
12…250 VDC
Varistor Circuit
AC/DC control
12…55 VAC / 12…77 VDC
56…136 VAC / 78…178 VDC
137…277 VAC / 181…350 VDC
RC Module
RC 24…48 VAC
RC 110…280 VAC
RC 380…480 VAC
24…48 V 50/60 Hz
110…280 V 50/60 Hz
380…480 V 50/60 Hz
Diode Circuit
Suppressor Module
for 100-C Contactors
For limiting switching overvoltage
of the solenoids.
• Can be plugged into coil terminals of all 100-C contactors
12…250 VDC
Varistor Circuit
12…55 VAC / 12…77 VDC
56…136 VAC / 78…180 VDC
137…277 VAC / 181…350 VDC
278…575 VAC
12…55 VAC / 12…77 VDC
56…136 VAC / 78…180 VDC
137…277 VAC / 181…350 VDC
278…575 VAC
Contact Safety Control
24…250 VDC
Suppressor Module
for CAB6 Contactors
For limiting surge voltage when
coil circuits are interrupted.
• Can be plugged into all CAB6
contactors
• Integrated EI- and DC control
in the protective circuit, or
delivered with separate suppressor module
➊ For overvoltage category IV (IEC
947 for CAB6...-EI) e.g., lightning
protection requirements
Options
✫ Package quantity
Cat. No. Suffix
No Entry
M
PQ
199-MSMA48
10
199-MSMA1
199-MSMNA48
100-M
199-MSMNA280
199-MSMNA480
199-MSMD1
2-wire version
2-wire version
10
100-M
199-MSMD2
199-MSMV4
199-MSMV5
199-MSMV6
10
100-M
100-FSC48W
100-FSC280W
100-FSC480W
100-FSC48
100-FSC280
100-FSC480
100-FSD250W
✫
✫
✫
✫
✫
✫
✫
100-FSD250
✫
100-FSV55W
100-FSV136W
100-FSV277W
100-FSV575W
100-FSV55
100-FSV136
100-FSV277
100-FSV575
✫
✫
✫
✫
✫
✫
✫
✫
100-FCC250W
✫
2-wire version
100-C,
100S-C with
AC control
2-wire version
100-C,100S-C
with
DC control
2-wire version
100-C,
100S-C with
AC / DC
control
All
100-C
RC Module (AC control)
21…48 V 50 Hz / 24…55 V 60 Hz
95…110 V 50 Hz / 110…127 V 60 Hz
CAB6-85…
CAB6-140
190…240 V 50 Hz / 220…277 V 60 Hz
380…550 V 50 Hz / 440…575 V 60 Hz
Varistor-Modul
for contactors with conventional
control
≤ 55 VAC
CAB6-85…
56…136 VAC
CAB6-140
137…277 VAC
278…575 VAC
for contactors with electronic control CAB6-105-EI…
24…28 VAC
CAB6-250-EI
CAB6-105-EI…
24…28 VDC
CAB6-300-EI
48…72 VDC
43…65 VAC
CAB6-105-EI…
208…277 VAC ➊
CAB6-420-EI
380…400 VAC
Description
Cat. No.
CRCB6-48
CRCB6-110
CRCB6-240
CRCB6-550
10
CRVB6-55
CRVB6-136
CRVB6-277
CRVB6-575
10
CRVB6-40
CRVB6-55
CRVB6-75
CRVB6-550
CRVB6-460
Ordering Example
Single pack (1 piece, standard)
100-FSC48
Multi-pack (10 pieces)
100-FSC48M
Product Selection - Page 4-10
4-30
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Mounting Materials
Description
Adapter
• For easy, toolless mounting of timers on to DIN Rails EN 50 022-35 and G Rails
Cat. No.
PQ
196-MTM
10
100-S0
100-S9
10
CAB6-HB1
CAB6-HB2
CAB6-HB3
1
CAB6-105-HU
CAB6-170-HU
825-ML630
1
Connection Pieces
• To link contactors (100-C) into combinations
Single wedge
0 mm
Wedge-type connector9 mm
Terminal Blocks
• Set of 2
• Protection class IP20 per IEC 529 and
DIN 40 050
For CAB6-85 / CAB6-105
For CAB6-105-EI / CAB6-170-EI
For CAB6-210-EI…CAB6-420-EI
Terminal Blocks UL / CSA
• Set of 3
For CAB6-85, CAB6-105
For CAB6-140, CAB6-105-EI…CAB6-170-EI
For CAB6-210-EI, CAB6-250-EI,
CAB6-300-EI, CAB6-420-EI
Control Circuit Terminal
• 2 x 2.5 mm2
For connecting to CAB6-85…170-EI
For connecting to CAB6-210-EI…420-EI
CAB6-AT
CAB6-AT2
10
Single Covers
• Set of 2
• Protection class IP10 per IEC 529 and
DIN 40 050
For CAB6-85, CAB6-105
For CAB6-140, CAB6-105-EI…CAB6-170-EI
For CAB6-210-EI…CAB6-420-EI
CAB6-HA1
CAB6-HA2
CAB6-HA3
1
Mounting Plate
• Galvanised passivated steel plate for
combination
Cover to Protect against Manual Operation
• Protection against unintended manual
operation
• For contactors and auxiliary contacts in safety
circuits
For CAB6-85…CAB6-170-EI
For direct-on-line starter
For reversing or two-speed starters
For Y-∆ or Dahlander starters
CAB6-105-PS
CAB6-105-PU
CAB6-105-PY
1
For CAB6-210-EI…CAB6-420-EI
For direct-on-line starter
For reversing or two-speed starters
For Y-∆ or Dahlander starters
CAB6-250-PS
CAB6-250-PU
CAB6-250-PY
For 100-C09..100-C85
For 100-FA, 100-FB, 100-FC, 100-FP, 100-FL
100-SCC
100-SCF
✫
PQ = Package Quantity
Product Selection - Page 4-10
Rockwell Automation
4-31
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Mounting Materials
Description
Connection Modules
• The connection module allows a safe and
easy electrical and
mechanical connection of contactor and
circuit breaker
• For DOL, reversing,
and star-delta starters
4
Enclosures
For Bulletin 100-C
contactors with Bulletin
overload relays 193-E
• For DOL starters
• Protection Class IP66
• Prestampings for two
pilot lights
For Use with
Connects:
Bulletin 140-M-C circuit breakers with Bulletin
100-M miniature contactors
Connects:
Bulletin 140-MN circuit breakers with Bulletin
100-M miniature contactors
140-KCD4
10
Connects:
Bulletin 140-MN circuit breakers with Bulletin
100-C contactors
140-NW23
✫
Without buttons
100-C09…C23
With blue RESET button
With green and red buttons: START / STOP, RESET
With green and extended red buttons: START / STOP, RESET
100-C09…C23
With blue RESET button
With green and red buttons: START / STOP, RESET
With green and extended red buttons: START / STOP, RESET
100-C30…C37
With white and black buttons: START / STOP, RESET
100-C09…C23
With white and extended black buttons: START / STOP, RESET
red
Pilot Light
• Mounting with plug-in coupling in upper enclosure part
• Connection cable length 180 mm
• Incl. glow lamp
green
white
120 V
240 V
400 V
120 V
240 V 198E-AY
400 V
120 V
240 V
400 V
Auxiliary Contact (START)
• For use with Cat. No. 198E-AY... enclosure
✫ Package quantity
✪ Package quantity
Cat. No. Suffix
No Entry
M
No Entry
M
PQ
140M-C-PEM12 ✫
With white and black buttons: START / STOP, RESET
100-C30…C37
With white and extended black buttons: START / STOP, RESET
Options
Cat. No.
Description
Single pack (1 piece, standard quantity)
100-C
198E-AYMN2
198E-AYMU1
198E-AYMU2
198E-AYMU4
198E-AYNU1
198E-AYNU2
198E-AYNU4
198E-AYMU3
198E-AYMU5
198E-AYNU3
198E-AYNU5
140-LR120
140-LR240
140-LR400
140-LG120
140-LG240
140-LG400
140-LW120
140-LW240
140-LW400
100-SD10
1
10
✪
Ordering Example
140M-C-PEM12
Multi-pack (20 pieces)
140M-C-PEM12M
Single pack (1 piece, standard quantity)
100-SD10
Multi-pack (10 pieces)
100-SD10M
PQ = Package Quantity
Product Selection - Page 4-10
4-32
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Mounting Materials
Description
Cat. No.
PQ
Connection Kits
Connection kits ease the wiring of reversing and star-delta starters, help to prevent wiring errors and therefore considerably contribute to cost minimizing.
Connection Kits
• For reversing switching
• For star-delta switching
Reversing switching
100-M
140-KCR4
Star-Delta switching
100-M
140-KCSD4
10
Reversing switching
100-C09…100-C23
100-C30…100-C37
100-C43
100-C60…100-C85
Star-Delta switching
100-C09…100-C23
100-C30…100-C37
100-C43
100-C60…100-C72
100-C85
For Bulletin CAB6-85 … CAB6-170-EI Contactors
45 mm2 input connections (for CAB6-..HU)
50 mm2 input connections (for CAB6-..HB)
45 mm2 output connections (for CAB6-..HU)
50 mm2 output connections (for CAB6-..HB)
«Neutral bridge» for CAB6-85…CAB6-170-EI
For Bulletin CAB6-210-EI … CAB6-420-EI Contactors
120 mm2 input connections (for CAB6-..HB3 and CAB6-..HU)
120 mm2 output connections (for CAB6-..HU)
120 mm2 output connections (for CAB6-..HB)
For Y-contactor CAB6-140-EI…CAB6-170-EI; 80 mm2
For Y-contactor CAB6-210-EI…CAB6-250-EI; 120 mm2
For Y-contactor
CAB6-210-EI…CAB6-250-EI; 120 mm2 (for CAB6-..HB)
«Neutral bridge» for CAB6-210-EI…CAB6-420-EI
Connection Kits
• For reversing switching
• For star-delta switching
Connecting Sets
4
105-PW23
105-PW37
105-PW43
105-PW85
170-PW23
170-PW37
170-PW43
170-PW72
170-PW85
1
CAB6-105-VLHU
CAB6-105-VLHB
CAB6-105-VT
CAB6-105-VTHB
CAB6-105-VYU
CAB6-250-VL
CAB6-250-VT
CAB6-250-VTHB
CAB6-250-VY
CAB6-250-VT
1
CAB6-250-VTHB
CAB6-250-VYU
Labelling Material
• Uniform labelling materials for contactors, motor protection devices, timing relays, and circuit breakers
Product information and ordering statements see chapter 3
Renewal Parts
Description
Arc Chambers for Contactors
• For 3-Pole CAB6 contactors
Main Contacts for Contactors
• Set for 3-Pole CAB6 contactors
For Use with
CAB6-85
CAB6-105
CAB6-105-EI
CAB6-140-EI
CAB6-170-EI
CAB6-210-EI
CAB6-250-EI
CAB6-300-EI
CAB6-420-EI
CAB6-85
CAB6-105
CAB6-105-EI
CAB6-140
CAB6-140-EI
CAB6-170-EI
CAB6-210-EI
CAB6-250-EI
CAB6-300-EI
CAB6-420-EI
Cat. No.
PQ
CAB6-85-ARC
CAB6-105-ARC
CAB6-105-EI-ARC
CAB6-140-EI-ARC
CAB6-170-EI-ARC
1
CAB6-210-EI-ARC
CAB6-250-EI-ARC
CAB6-300-EI-ARC
CAB6-420-EI-ARC
CAB6-85-CONT-1
CAB6-105-CONT-2
CAB6-105-EI-CONT-22
CAB6-140-CONT-33
CAB6-140-EI-CONT-3
1
CAB6-170-EI-CONT-4
CAB6-210-EI-CONT-5
CAB6-250-EI-CONT-6
CAB6-300-EI-CONT-7
CAB6-420-EI-CONT-8
Product Selection - Page 4-10
Rockwell Automation
4-33
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Renewal Parts: Coils for Bulletin 100-C, 100S-C Contactors
4
AC 100-C09… 100-C23… 100-C43 100-C60…
100-C16 100-C37
100-C85 DC Control Voltage
Coil
Code
PQ = 10
PQ = 1
AC Control
Voltage
50 Hz
60 Hz
50/60 Hz
12 V
12 V
24 V
24 V
24 V
32 V
36 V
42 V
48 V
36 V
48 V
48 V
100 V
110 V
100…110V
120 V
110 V
120 V
127 V
200 V
200…220V
200…230 V
220 V
220…230 V
208…240 V
240 V
230 V
230…240 V
240 V
277 V
240 V
380…400 V
347 V
380 V
440 V
400 V
400…415 V
440 V
480 V
440 V
500 V
550 V
600 V
Cat. No.
Cat. No.
Cat. No.
Cat. No.
Q
R
J
K
KJ
V
W
X
Y
KY
KP
D
KD
P
S
KG
KL
L
A
F
KF
VA
T
KA
I
E
N
TA006
TA404
TA013
TA407
TA855
TA481
TA410
TA482
TA414
TA860
TA861
TA473
TA856
TA425
TA428
TA862
TA864
TA296
TA474
TA441
TA851
TA440
TA480
TA858
TA065
TA067
TA071
TC006
TC404
TC013
TC407
TC855
TC481
TC410
TC482
TC414
TC860
TC861
TC473
TC856
TC425
TC428
TC862
TC864
TC296
TC474
TC441
TC851
TC440
TC480
TC858
TC065
TC067
TC071
TD006
TD404
TD013
TD407
TD855
TD481
TD410
TD482
TD414
TD860
TD861
TD473
TD856
TD425
TD428
TD862
TD864
TD296
TD474
TD441
TD851
TD440
TD480
TD858
TD065
TD067
TD071
TE006
TE404
TE013
TE407
TE855
TE481
TE410
TE482
TE414
TE860
TE861
TE473
TE856
TE425
TE428
TE862
TE864
TE296
TE474
TE441
TE851
TE440
TE480
TE858
TE065
TE067
TE071
KN
TA863
TC863
TD863
TE863
G
TA457
TC457
TD457
TE457
B
TA475
TC475
TD475
TE475
KB
M
C
TA859
TA479
TA476
TC859
TC479
TC476
TD859
TD479
TD476
TE859
TE479
TE476
DC 100-C09… 100-C23… 100-C43 100-C60…
100-C85
Coil 100-C16 100-C37
Code
PQ = 10
PQ = 1
VDC
9V➊
12 V
24 V ➋
36 V
48 V
60 V
64 V
72 V
80 V
110 V
115 V
125 V
220 V
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
integr. diode
230 V
diode circuit
included
250 V
diode circuit
included
Price Adder for:
Type
Special control voltages
100-C09 … 100-C85
For special voltages, please contact sales office
Cat. No.
Cat. No.
Cat. No.
Cat. No.
ZR
DR
ZQ
DQ
ZJ
DJ
ZW
DW
ZY
DY
ZZ
DZ
ZB
DB
ZG
DG
ZE
DE
ZD
DD
ZP
DP
ZS
DS
ZA
DA
ZF
TA766
—
TA708
—
TA714
TA714M
TA719
—
TA724
—
TA774
—
TA727
—
TA728
—
TA729
—
TA733
—
TA734
—
TA737
—
TA747
—
TA749
TC766—
TC708
—
TC714
TC714M
TC719
—
TC724
—
TC774
—
TC727
—
TC728
—
TC729
—
TC733
—
TC734
—
TC737
—
TC747
—
TC749
TD766—
TD708
—
TD714
TD714M
TD719
—
TD724
—
TD774
—
TD727
—
TD728
—
TD729
—
TD733
—
TD734
—
TD737
—
TD747
—
TD749
—
TE766M
—
TE708M
—
TE714M
—
TE719M
—
TE724M
—
TE774M
—
TE727M
—
TE728M
—
TE729M
—
TE733M
—
TE734M
—
TE737M
—
TE747M
—
DF
—
—
—
TE749F
ZD
TA751
TC751
TD751
—
DT
—
—
—
TE751F
Available Control Voltages
No Surcharge
12…500 V 50 Hz, 12…600 V 60 Hz,
12 … 250 VDC
> 20 pieces
➊ Extended operating limits 0.65…1.3 x Us
➋ Extended operating limits 0.7…1.25 x Us
PQ = Package Quantity
Product Selection - Page 4-10
4-34
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Accessories
Renewal Parts: Coils and Supply Modules for Bulletin CAB6 Contactors
Description
Variations
For Use with
Cat. No.
PQ
AC control
CAB6-105-COIL-⊗
CAB6-85…CAB6-140
Conventional
CAB6-105-EI…CAB6-250-EI (24…28 V 50/60 Hz) CAB6-250-EI-COIL-05
CAB6-300-EI-COIL-⊗
Electronic ➋ CAB6-105-EI…CAB6-300-EI
CAB6-420-EI-COIL-⊗
CAB6-420-EI
DC control
CAB6-105-COIL-⊗
CAB6-85…CAB6-140
Conventional
4
Set:
Coils and Supply Modules
for CAB6 Contactors
For replacement only
CAB6-105-EI…CAB6-300-EI
CAB6-300-EI-COIL-⊗
CAB6-420-EI
CAB6-420-EI-COIL-⊗
1
Electronic ➋
Options
Cat. No. Suffix
⊗ Voltage suffix code
e.g. 54
Description
Ordering Example
Voltage suffix code from table below
CAB6-105-COIL-54
⊗ Voltage Suffix Codes for AC Control
[V]
CAB6-85…CAB6-140 ➊
24
28
48
55
110
127
220230
230
240
260
277
380400
415
440460
480
50 Hz
05
—
08
—
10
—
13
—
(15)
—
—
16
(17)
—
—
60 Hz
—
05
—
08
—
10
—
—
—
13
(15)
—
—
16
(17)
—
—
54
(55)
—
—
—
—
—
—
50/60 Hz
—
—
—
—
(48)
2428
4365
110130
208277
380400
50/60 Hz
05
08
10
—
08
10
14
14
16
CAB6-300-EI…CAB6-420-EI 50/60 Hz
24
48
110
220
CAB6-105-EI…CAB6-250-EI
16
⊗ Voltage Suffix Codes for DC Control
[V]
CAB6-85…CAB6-140
DC
66
(70)
76
(86)
2428
4872
90135
110135
170255
DC
66
(70)
76
—
(86)
—
DC
—
(70)
—
76
—
(86)
CAB6-105-EI…CAB6-300-EI
CAB6-420-EI
Price Adder for:
Special control voltages
Type
CAB6-85…CAB6-140 ➊
190255
Available Control Voltages
No Surcharge
21…550 V 50 Hz, 24…575 V 60 Hz,
110…240 V 50/60 Hz, 24 … 240 VDC
> 25 pieces
( ) Control voltages in parentheses: No inventory
➊ 50/60 Hz coil only available for CAB6-85 and 105
➋ Will be delivered only as set coil and supply module
PQ = Package Quantity
Product Selection - Page 4-10
Rockwell Automation
4-35
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
IEC Specifications
100-M
4
AC-1 Active Power Load, Switching of 3-phase
Motors
Ambient temperature 40 °C
Ie
≤ 500 V
[A]
690 V
[A]
1000 V
[A]
230 V
[kW]
240 V
[kW]
400 V
[kW]
415 V
[kW]
500 V
[kW]
690 V
[kW]
1000 V
[kW]
Ambient temperature 60 °C
Ie
≤ 500 V
[A]
690 V
[A]
1000 V
[A]
230 V
[kW]
240 V
[kW]
400 V
[kW]
415 V
[kW]
500 V
[kW]
690 V
[kW]
1000 V
[kW]
Switching of 3-phase Motors
Ambient temperature 60 °C
AC-2, AC-3, AC-4
230 V
[A]
240 V
[A]
400 V
[A]
415 V
[A]
500 V
[A]
690 V
[A]
1000 V
[A]
230 V ➌
[kW]
240 V ➌
[kW]
400 V ➌
[kW]
415 V ➌
[kW]
500 V ➌
[kW]
690 V ➌
[kW]
1000 V ➌
[kW]
AC-4 at approximately 200 000 operations
230 V
[A]
240 V
[A]
400 / 415V
[A]
500 V
[A]
690 V
[A]
1000 V
[A]
230 V ➌
[kW]
240 V ➌
[kW]
400 V ➌
[kW]
415 V ➌
[kW]
500 V ➌
[kW]
690 V ➌
[kW]
1000 V ➌
[kW]
Max. switching frequency
Sch/h
100-C, 100S-C
05
09
12
09
12
16
23
30
37
20
—
—
8
8.3
14
14
17
—
—
20
—
—
8
8.3
14
14
17
—
—
20
—
—
8
8.3
14
14
17
—
—
32
32
—
13
13
22
23
28
38
—
32
32
—
13
13
22
23
28
38
—
32
32
—
13
13
22
23
28
38
—
32 (40) ➊
32 (40) ➊
—
13
13
22
23
28
38
—
50
50
—
20
21
35
36
43
60
—
50
50
—
20
21
35
36
43
60
—
16
—
—
6.4
6.7
11
12
14
—
—
16
—
—
6.4
6.7
11
12
14
—
—
16
—
—
6.4
6.7
11
12
14
—
—
32
32
—
13
13
22
23
28
38
—
32
32
—
13
13
22
23
28
38
—
32
32
—
13
13
22
23
28
38
—
32
32
—
13
13
22
23
28
38
—
45
45
—
18
19
31
32
39
54
—
45
45
—
18
19
31
32
39
54
—
6.5
6.5
5.3
5.3
4
—
—
1.5
1.5
2.2
2.2
2.2
—
—
12
12
9
9
7
—
—
3
3
4
4
4
—
—
12
12
12 ➋
12 ➋
7
—
—
3
3
5.5 ➋
5.5 ➋
4
—
—
12
12
9
9
7
5
—
3
3
4
4
4
4
—
15
15
12
12
10
7
—
4
4
5.5
5.5
5.5
5.5
—
20
20
16
16
14
9
—
5.5
5.5
7.5
7.5
7.5
7.5
—
26.5
26.5
23
23
20
12
—
7.5
7.5
11
11
13
10
—
35
35
30
30
25
18
—
10
10
15
15
15
15
—
38
38
37
37
30
21
—
11
11
18.5
20
20
18.5
—
2.3
2.3
2
1.9
—
—
0.37
0.37
0.75
0.75
0.75
—
—
250
3.9
3.9
3.3
3.2
—
—
0.75
0.75
1.1
1.1
1.5
—
—
250
3.9
3.9
3.3
3.2
—
—
0.75
0.75
1.1
1.1
1.5
—
—
250
4.3
4.3
4.3
4.3
4.3
—
0.75
0.75
1.8
1.8
2.2
3
—
250
6.6
6.6
6.6
6.6
6.6
—
1.5
1.5
3
3
3.7
5.5
—
250
9
9
9
9
9
—
2.2
2.2
4
4
5.5
7.5
—
220
10
10
10
10
10
—
2.2
2.2
4
4
5.5
7.5
—
200
12
12
12
12
12
—
3
3
5.5
5.5
7.5
10
—
200
14
14
14
14
14
—
3.7
4
6.3
6.3
7.5
11
—
200
➊ Values in ( ) with increased cross-section and cable lug
➋ Max. switching frequency
➌ Power ratings: Preferred values according to IEC 60072-1
Product Selection - Page 4-10
4-36
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-C, 100S-C
CAB6
43
60
72
85
-85
-105(-EI)
-140
-140-EI
-170-EI
-210-EI
-250-EI
-300-EI
-420-EI
85
85
—
34
35
59
61
74
102
—
100
100
—
40
42
69
72
87
120
—
100
100
—
40
42
69
72
87
120
—
100
100
—
40
42
69
72
87
120
—
160
160
160
64
67
111
115
139
191
277
160
160
160
64
67
111
115
139
191
277
250
250
250
100
104
173
180
217
299
433
250
250
250
100
104
173
180
217
299
433
250
250
250
100
104
173
180
217
299
433
350
350
350
139
145
242
252
303
418
606
350
350
350
139
145
242
252
303
418
606
450
450
450
179
187
312
323
390
538
779
500
500
500
199
208
346
359
433
598
866
63
63
—
25
26
44
45
55
75
—
100
100
—
40
42
69
72
87
120
—
100
100
—
40
42
69
72
87
120
—
100
100
—
40
42
69
72
87
120
—
135
.135
135
54
56
94
97
117
161
234
135
135
135
54
56
94
97
117
161
234
210
210
210
84
87
145
151
182
251
364
210
210
210
84
87
145
151
182
251
364
210
210
210
84
87
145
151
182
251
364
300
300
300
120
125
208
216
260
359
520
300
300
300
120
125
208
216
260
359
520
380
380
380
151
158
263
273
329
454
658
425
425
425
169
177
294
305
368
508
736
44
44
43
43
38
25
—
13
13
22
22
25
22
—
62
62
60
60
55
34
—
18.5
18.5
32
32
37
32
—
72
72
72
72
67
42
—
22
22
40
40
45
40
—
85
85
85
85
80
49
—
25
25
45
45
55
45
—
85
85
85
85 (95)➍
85
85
33
25
25
45
45 (55)➍
55
80
45
16.5
16.5
16.5
16.5
16.5
—
4
4
7.5
7.5
10
15
—
200
25.5
25.5
25.5
25.5
25.5
—
6.3
7.5
13
13
15
22
—
120
31
31
31
31
31
—
7.5
7.5
15
17
20
25
—
120
38
38
38
38
38
—
11
11
20
20
25
32
—
120
43
43
43
43
43
19
13
13
22
22
25
40
22
100
105
140
140
105
140
140
105
140
140
105 (130)➍ 140 (155)➍ 140 (155)➍
105
115
140
105
115
140
40
55
55
32
45
45
32
45
45
55
75
75
55 (75)➍
80 (90)➍
80 (90)➍
63
80
90
100
110
132
55
75
75
50
50
50
50
50
23
15
15
25
25
32
45
30
100
60
60
60
60
60
37
17
18.5
32
32
40
55
50
100
60
60
60
60
60
37
17
18.5
32
32
40
55
50
100
170
170
170
170
170
170
65
55
55
90
100
110
160
90
67
67
67
67
67
43
20
22
37
37
45
63
55
100
210
250
300
420
210
250
300
420
210
250
300
420
210 (227)➍ 250 (258)➍ 300 (315)➍ 420 (425)➍
210
250
300
420➋
210
250
300
420➋
80
95
115
160
63
80
90
132
63
80
100
132
110
132
160
220
125 (132)➍
150
160 (185)➍
250
150
160
200
300 ➎
200
250
300
425 ➎
110
132
160
220
85
85
85
85
85
60
25
25
45
50
55
80
80
50
105
105
105
105
105
72
32
32
55
55
75
100
100
50
140
140
140
140
140
85
45
45
75
80
100
132
110
50
170
170
170
170
170
105
55
55
90
100
110
160
150
50
➍ 415 V: values in ( ) AC-3 and AC-4 lifespan -25 %
➎ Value applies only to AC-2 and AC-3; AC-4: 360 A
Product Selection - Page 4-10
Rockwell Automation
4-37
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
IEC Specifications
100-M
100-C, 100S-C
05
09
12
09
12
16
23
30
37
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
11
11
9.2
9.2
6.9
—
—
3
3
4
4
4
—
—
21
21
16
16
12
—
—
5.5
5.5
7.5
7.5
7.5
—
—
21
21
21
21
12
—
—
5.5
5.5
10
11
7.5
—
—
21
21
16
16
12
8.6
—
5.5
5.5
7.5
7.5
7.5
7.5
—
26
26
21
21
17
12
—
7.5
7.5
10
11
11
10
—
35
35
28
28
24
16
—
10
10
13
15
15
13
—
46
46
40
40
35
21
—
13
13
20
22
22
18.5
—
61
61
52
52
43
31
—
17
18.5
25
25
25
25
—
66
66
64
64
52
36
—
20
20
32
37
32
32
—
max. [A]
max. [A]
max. [A]
25
16
—
25
16
—
25
16
—
50
25
25
50
35
35
50
35
35
80
40
40
125
80
80
125
80
80
Star-Delta Starting
4
≤ 230 V
≤ 240 V
400 V
415 V
500 V
690 V
1 000 V
230 V ➊
240 V ➊
400 V ➊
415 V ➊
500 V ➊
690 V ➊
1 000 V ➊
Short-circuit Protection of Contactors
without Motor Protection Relays
Max. fuse gG per IEC 947-4-1
Type «1» Coordination
Type «2» Coordination
400 V
Type «2» Coordination
690 V
➊ Power ratings: Preferred values according to IEC 60072-1
Product Selection - Page 4-10
4-38
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-C, 100S-C
CAB6
43
60
72
85
76
76
74
74
66
43
—
22
22
40
40
45
40
—
107
107
104
104
95
59
—
32
32
55
55
63
55
—
125
125
125
125
116
73
—
37
40
63
63
80
63
—
147
147
147
147
139
85
—
45
50
80
80
90
80
—
160
100
100
250
160
160
250
160
160
250
160
160
-85
-105(-EI)
-140
-140-EI
147
182
242
242
147
182
242
242
147
182
242
242
147 (164)➊ 182 (225)➊ 242 (268)➊ 242 (268)➊
147
182
199
242
147
182
199
242
55
65
96
96
45
55
75
75
50
63
80
80
80
100
132
132
80 (90)➊ 100 (132)➊ 132 (160)➊ 132 (160)➊
100
132
132
160
132
160
200
220
75
90
132
132
250
200
200
250
200
200
315
250
250
315
250
250
-170-EI
294
294
294
294
294
294
112
90
100
160
160
200
300
160
355
315
315
-210-EI
-250-EI
-300-EI
-420-EI
364
433
520
727
364
433
520
727
364
433
520
727
364 (393)➊ 433 (447)➊ 520 (546)➊ 727 (736)➊
364
433
520
727
364
433
520
727
139
165
200
277
110
132
160
220
125
150
160
250
200
250
300
425
220
250
315 (335)➊ 425 (450)➊
250
315
375
530
355
425
530
750
200
220
280
400
500
400
400
500
400
400
630
500
500
630
500
500
➊ 415V: Values in ( ) AC-3 lifespan -25 %
Product Selection - Page 4-10
Rockwell Automation
4-39
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
IEC Specifications
100-M
100-C, 100S-C
05
09
12
09
12
16
23
30
37
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[kVA]
[kVA]
[kVA]
[kVA]
[kVA]
[kVA]
[kVA]
[A]
[A]
2.9
2.9
2.4
2.4
1.8
—
—
1.2
1.2
1.7
1.7
1.6
—
—
—
—
5.4
5.4
4.1
4.1
3.2
—
—
2.2
2.2
2.8
2.9
2.7
—
—
—
—
5.4
5.4
5.4
5.4
3.2
—
—
2.2
2.2
3.7
3.9
2.7
—
—
—
—
10.9
10.9
10.9
10.9
10.9
10.9
—
4.3
4.5
7.5
7.8
9.4
13
—
16.3
22
10.9
10.9
10.9
10.9
10.9
10.9
—
4.3
4.5
7.5
7.8
9.4
13
—
16.3
22
10.9
10.9
10.9
10.9
10.9
10.9
—
4.3
4.5
7.5
7.8
9.4
13
—
16.3
22
10.9
10.9
10.9
10.9
10.9
10.9
—
4.3
4.5
7.5
7.8
9.4
13
—
16.3
22
20
20
20
20
20
20
—
8
8.3
14
14
17
24
—
30
40
20
20
20
20
20
20
—
8
8.3
14
14
17
24
—
30
40
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
[kVar]
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
8
8
8
8
8
8
8
8
8
8
8
8
8.5
8.5
10
10
10
10
9
9
12.5
12.5
12.5
12.5
14
14
20
20
20
20
14
14
24
25
25
25
—
—
—
—
—
—
8
8
8
8
8
8
8
8
8
8
8
8
8.5
8.5
10
10
10
10
9
9
12.5
12.5
12.5
12.5
12.5
12.5
20
20
20
20
12.5
12.5
21.5
22
25
25
—
—
—
—
—
—
5
5
5
5
5
5
5
5
5
5
5
5
8
8
8
8
8
8
9
9
10
10
10
10
12.5
12.5
15
15
15
15
14
14
20
20
20
20
—
—
—
—
—
—
5
5
5
5
5
5
5
5
5
5
5
5
8
8
8
8
8
8
9
9
10
10
10
10
12.5
12.5
15
15
15
15
12.5
12.5
20
20
20
20
—
—
—
—
—
—
Switching of Power Transformers, AC-6a
Inrush current
Rated transformer
=n
≤ 230 V
≤ 240 V
≤ 400 V
415 V
≤ 500 V
≤ 690 V
≤ 1000 V
230 V
240 V
400 V
415 V
500 V
690 V
1000 V
n = 20
≤ 690 V
n = 15
≤ 690 V
Switching of 3-phase Capacitors, AC-6b
Inductance of leads between capacitors
in parallel: min. 6 µH
(100-C09...-C30 contactors: min. 30 µH)
Single capacitors 40 °C
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
60 °C
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
Group capacitors 40 °C
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
60 °C
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
n = 30
4
Product Selection - Page 4-10
4-40
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-C, 100S-C
CAB6
43
60
72
85
-85
-105(-EI)
-140(-EI)
-170-EI
-210-EI
-250-EI
-300-EI
-420-EI
23
23
23
23
23
23
—
9.2
10
16
17
20
27
—
34.5
46
40.8
40.8
40.8
40.8
40.8
40.8
—
16
17
28
29
35
49
—
61.3
82
40.8
40.8
40.8
40.8
40.8
40.8
—
16
17
28
29
35
49
—
61.3
82
40.8
40.8
40.8
40.8
40.8
40.8
—
16
17
28
29
35
49
—
61.3
82
53
53
53
53
53
53
53
21
22
37
38
46
64
92
80
107
60
60
60
60
60
60
60
24
25
42
43
52
72
104
90
120
70
70
70
70
70
70
70
28
29
48
50
61
84
121
105
140
85
85
85
85
85
85
85
34
35
59
61
74
102
147
128
170
105
105
105
105
105
105
105
42
44
73
75
91
125
182
158
210
125
125
125
125
125
125
125
50
52
87
90
108
149
217
188
250
150
150
150
150
150
150
150
60
62
104
108
130
179
260
225
300
210
210
210
210
210
210
210
84
87
145
151
182
251
364
315
420
24
25
35
35
35
35
28
29
48
50
50
50
28
29
48
50
55
55
28
29
48
50
60
60
45
48
78
80
98
133
193
33
35
58
60
73
100
145
45
47
58
60
60
60
60
33
35
58
60
60
60
60
45
48
78
80
98
133
193
33
35
58
60
73
100
145
40
45
75
78
78
78
80
35
38
58
60
73
78
80
70
73
120
125
150
208
300
60
63
100
105
128
175
253
70
73
98
98
100
100
100
58
60
98
98
100
100
100
70
73
120
125
150
208
300
60
63
100
105
128
175
253
70
73
120
123
123
123
125
58
60
100
105
123
123
125
98
102
170
176
212
293
424
84
87
145
151
182
251
364
98
102
170
170
172
174
177
84
87
145
151
172
174
177
98
102
170
176
212
293
424
84
87
145
151
182
251
364
98
102
170
176
212
247
251
84
87
145
151
182
247
251
125
131
218
226
273
376
546
106
111
184
191
230
318
461
125
131
218
226
273
356
361
106
111
184
191
230
318
361
139
145
242
252
303
418
606
119
124
206
214
258
356
515
139
145
242
252
303
418
606
119
124
206
214
258
356
515
—
—
—
—
18
18
30
30
30
30
28
29
42
42
42
42
28
29
48
50
50
50
28
29
48
50
55
55
—
—
—
—
20
20
25
25
25
25
28
29
40
40
40
40
28
29
48
50
50
50
28
29
48
50
50
50
—
—
—
—
18
18
25
25
25
25
—
28
29
40
40
40
40
—
28
29
48
50
50
50
—
28
29
48
50
50
50
—
Product Selection - Page 4-10
Rockwell Automation
4-41
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
IEC Specifications
100-M
09
12
09
12
16
23
30
37
[A]
[A]
18
14.5
18
14.5
18
14.5
22.5
22.5
25
25
28
28
29
29
40.5
37
45
41
10 kA
[µF]
20 kA
[µF]
50 kA
[µF]
Filament AC-5b
230/240 V
[A]
Switching of Low Inductive Loads in Home Appliances and
Similar Applications
AC-7a
230 V
[A]
400 V
[A]
440 V
[A]
Switching of Motor Load for Home Appliances
AC-7b
230 V
[A]
400 V
[A]
440 V
[A]
Switching of Hermetically Sealed Cooling Compressor Motors
- manual reset of overload release
AC-8a
400 V
[A]
500 V
[A]
690 V
[A]
- automatic reset of overload release
AC-8b
400 V
[A]
500 V
[A]
690 V
[A]
Switching of DC Loads
non-inductive or slightly inductive loads or resistance
furnaces DC-1 at 60 °C
1 pole
24 V
[A]
48/60 V
[A]
110 V
[A]
220 V
[A]
440 V
[A]
2 poles in series
24 V
[A]
48/60 V
[A]
110 V
[A]
220 V
[A]
440 V
[A]
3 poles in series
24 V
[A]
48/60 V
[A]
110 V
[A]
220 V
[A]
440 V
[A]
Shunt-wound Motors
Starting, reverse current braking, reversing
stepping DC-3, 60 °C
3 poles in series
24 V
[A]
48/60 V
[A]
110 V
[A]
220 V
[A]
440 V
[A]
Series-wound Motors
Starting, reverse current braking, reversing
stepping DC-5, 60 °C
3 poles in series
24 V
[A]
48/60 V
[A]
110 V
[A]
220 V
[A]
440 V
[A]
Short Time Withstand ICW, 60 °C
10 s
[A]
750
400
—
9.3
750
400
—
9.3
750
400
—
9.3
1 000
500
200
12
1 000
500
200
16
1 000
500
200
18
1 000
500
200
22
2 700
1 350
540
30
2 700
1 350
540
37
—
—
—
—
—
—
—
—
—
32
32
32
32
32
32
32
32
32
32
32
32
45
45
45
45
45
45
—
—
—
—
—
—
—
—
—
10.5
9
7.5
14
12
10
19
16
13.5
23
20
18
30
30
27
—
—
—
—
—
—
—
—
—
—
—
—
12
12
8
16
16
10
22
22
14
32
32
20
38
38
28
45
45
35
—
—
—
—
—
—
—
—
—
5.5
5.5
5.5
7
7
7
9.3
9.3
9.3
12
12
12
13
13
13
14
14
14
6
4/1
0.6
0.2
0.08
6
6
4
0.8
0.2
6
6
6
3
0.4
9
6/1.5
1
0.3
0.1
9
8
6
1.2
0.3
9
9
9
4
0.6
9
6/1.5
1
0.3
0.1
9
8
6
1.2
0.3
9
9
9
4
0.6
25
20
6
1.5
0.4
25
25
25
8
1
25
25
25
25
3
25
20
6
1.5
0.4
25
25
25
8
1
25
25
25
25
3
32
20
6
1.5
0.4
32
32
32
8
1
32
32
32
32
3
32
20
6
1.5
0.4
32
32
32
10
1
32
32
32
32
3
45
25
8
1.5
0.4
45
45
45
10
1
45
45
45
45
3.5
45
25
8
1.5
0.4
45
45
45
10
1
45
45
45
45
3.5
5
4
2
0.8
0.15
9
6
3
1.2
0.2
9
6
3
1.2
0.2
25
25
20
6
0.6
25
25
20
6
0.6
32
32
25
6
0.6
32
32
25
10
0.6
45
45
30
15
0.6
45
45
30
15
0.6
5
2
0.6
0.1
—
9
3
1
0.1
—
9
3
1
0.1
—
25
25
20
6
0.6
25
25
20
6
0.6
32
32
25
6
0.6
32
32
25
10
0.6
45
45
30
15
0.6
45
45
30
15
0.6
60
96
96
170
170
170
215
300
304
Switching of Lamps
Gas discharge lamps AC-5a
Individually compensated:
Max. capacitance at expected
Short-circuit current of
4
100-C, 100S-C
05
open
closed
Product Selection - Page 4-10
4-42
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-C, 100S-C
CAB6
43
60
72
85
-85
-105(-EI)
-140(-EI)
-170-EI
-210-EI
-250-EI
-300-EI
-420-EI
77
57
81
77
85
81
90
90
144
121.5
144
121.5
225
189
225
189
315
270
315
270
405
342
420
382.5
3 200
1 600
640
43
4 000
2 000
800
60
4 000
2 000
800
70
4 700
2 350
940
76
—
—
—
107
—
—
—
120
—
—
—
140
—
—
—
170
—
—
—
273
—
—
—
273
—
—
—
300
—
—
—
420
63
63
63
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
63
63
42
72
72
56
85
85
67
100
100
80
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
16
16
16
24
24
24
30
30
30
35
35
35
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
50
30
9
1.5
0.5
50
50
50
10
1
63
63
63
50
4
70
40
11
2
0.5
70
70
70
15
1.5
90
90
90
70
5
80
40
11
2
0.5
80
80
80
15
1.5
90
90
90
80
5
80
40
11
2
0.5
80
80
80
15
1.5
100
100
100
80
5
120
120
120
3
0.6
120
120
120
120
3
120
120
120
120
11
120
120
120
3
0.6
120
120
120
120
3
120
120
120
120
11
210
210
210
4
1
210
210
210
210
4
210
210
210
210
11
210
210
210
4
1
210
210
210
210
4
210
210
210
210
11
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
63
50
35
20
0.6
90
70
70
25
0.6
90
70
70
25
0.6
100
80
80
30
0.6
120
120
120
120
3
120
120
120
120
3
210
210
210
210
4
210
210
210
210
4
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
63
50
35
20
0.6
90
70
70
25
0.6
90
70
70
25
0.6
100
80
80
30
0.6
80
80
80
80
1.2
80
80
80
80
1.2
120
120
120
120
2
120
120
120
120
2
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
375
700
700
700
1060
1060
1 390
1 390
2 300
2 570
2 800
4 290
Product Selection - Page 4-10
Rockwell Automation
4-43
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Specifications
100-M
4
Resistance and Power Dissipation
Main current circuit resistance
[mΩ]
Power dissipation by all circuits
[W]
at Ie AC-3/400 V
Total power dissipation
AC control
[W]
at Ie AC-3/400 V
DC control
[W]
Load Carrying Capacity per UL/CSA
Lloyd’s Register of Shipping
Continuous current
(open)
[A]
(enclosed)
[A]
Rated power
3-phase motors, 60 Hz, enclosed
(Direct-on-line) 1-phase
115 V
[HP]
230 V
[HP]
3-phase
200 V
[HP]
230 V
[HP]
460 V
[HP]
575 V
[HP]
(Reversing combinations) 3-phase 200 V
[HP]
230 V
[HP]
460 V
[HP]
575 V
[HP]
Lifespan
Mechanical
AC control
[Mio. operations.
DC control
[Mio. operations]
Electrical
AC-3 (400 V)
[Mio. operations]
Weight
AC control
[kg]
DC control
[kg]
100-C, 100S-C
05
09
12
09
12
16
23
30
37
5.5
5.5
5.5
2.7
2.7
2.7
2
2
2
0.46
1.3
2.4
0.66
1.2
2.1
3.2
5.4
8.2
1.9
3.0
2.7
3.8
3.8
4.9
3.3
6.7
3.8
7.2
4.7
8.1
6.2
12.4
8.4
14.6
11.2
17.4
12
12
12
12
12
12
25
25
25
25
30
30
30
30
45
45
50
50
0.5
1
1.5
1.5
3
3
1.5
1.5
3
3
0.5
1.5
2
2
5
5
2
2
5
5
0.5
2
3
3
7.5
10
3
3
7.5
10
0.5
1.5
2
2
5
7.5
2
2
5
7.5
0.5
2
3
3
7.5
10
3
3
7.5
10
1
3
5
5
10
15
5
5
10
15
2
3
5
7.5
15
15
5
7.5
15
15
2
5
7.5
10
20
25
7.5
10
20
25
3
5
10
10
25
30
10
10
25
30
10
20
0.7
10
20
0.7
10
20
0.7
13
13
1.3
13
13
1.3
13
13
1.3
13
13
1.3
13
13
1.3
13
13
1.3
0.16
0.16
0.16
0.16
0.16
0.16
0.39
0.6
0.39
0.6
0.39
0.61
0.39
0.73
0.48
0.85
0.49
0.85
Product Selection - Page 4-10
4-44
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-C, 100S-C
CAB6
43
60
72
85
-85
-105(-EI)
-140(-EI)
-170-EI
-210-EI
-250-EI
-300-EI
-420-EI
1.5
0.9
0.9
0.9
0.4
0.4
0.42
0.42
0.22
0.22
0.18
0.15
8.3
9.7
14
19.5
8.7
13.2 (13.8)
24.6
36.3
29.4
41.7
48.6
79.5
11.5
18.4
11
11
13.8
13.8
17.5
17.5
18.2
16.7
22.7
20.9
34.5
32.5
46.5
44.5
39.4
37.4
51.7
49.7
58.6
56.6
89.5
87.5
63
63
90
90
90
90
100
100
178
160
178
160
250
220
250
220
350
300
350
300
420
340
500
420
3
7.5
10
15
30
30
10
15
30
30
5
10
15
20
40
50
15
20
40
50
5
15
20
25
50
60
20
25
50
60
7.5
15
25
30
60
60
25
30
60
60
7.5
15
25
30
60
75
25
30
60
75
10
25
40
40
75
100
40
40
75
100
15
30
40
50
100
125
40
50
100
125
—
40
50
60
150
150
50
60
150
150
—
50
60
75
150
200
60
75
150
200
—
—
75
100
200
250
75
100
200
250
—
—
100
125
250
300
100
125
250
300
—
—
150
175
350
400
117
135
278
350
12
13
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
10
10
1
0.51
1.0
1.45
1.47
1.45
1.47
1.45
1.47
3.3
3.3
3.3 (3.8)
3.3 (3.8)
3.3 (3.8)
3.3 (3.8)
3.8
3.8
7.5
7.5
7.5
7.5
7.5
7.5
7.5
7.5
Product Selection - Page 4-10
Rockwell Automation
4-45
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-M
05
4
c
c
s
s
b
b
c
s
b max.
c max.
s max.
o min.
s
Recommended torque[Nm]
Cross section per UL/CSA
23
30
37
➋
➊
2.5 … 10
2.5 … 10
0.75 … 2.5
0.75 … 2.5
1.5 … 6
1.5 … 6
2.5 … 16
2.5 … 16
[mm]
[mm]
[mm]
[mm]
—
—
—
—
—
—
—
—
—
[lb-in]
1. conductor
2. conductors
b max.
s top
s bottom
[mm2]
[mm2]
[mm]
[mm]
[mm]
top
bottom
[AWG]
[AWG]
[lb-in]
Recommended torque
16
1…4
1…4
[Nm]
[AWG]
s
b
12
0.75 … 2.5
0.75 … 2.5
1. conductor [mm2]
2. conductors [mm2]
b
09
[mm2]
[mm2]
[mm2]
[mm2]
b
Recommended torque
Cross section per UL/CSA
With terminal lug kit
Recommended torque
With Frame Terminal Block
12
➊
Terminal Cross Sections - Main Contacts
Terminal type
1. conductor
2. conductors
1. conductor[
2. conductors
100-C, 100S-C
09
—
—
—
1 … 1.5
18 … 14
—
7 … 15
1 … 2.5
16 … 10
—
8.9 … 22
1.5 … 3.5
14 … 6
—
13 … 31
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Control Circuits
100-M
05
Operating limits
50 Hz, 60 Hz, 50/60 Hz
09
100-C, 100S-C
12
09
12
16
23
30
37
pick-up
dropout
pick-up
dropout
[x Us]
[x Us]
[x Us]
[x Us]
0.85…1.1
0.35…0.65
0.85…1.1
0.1…0.25
pick-up
holding
pick-up
holding
[VA/W]
[VA/W]
[W]
[W]
22/20
4/1.4
2.5
2.5
70/50
8/2.6
6.5
6.5
70/50
9/3
9.2
9.2
80/60
9/3
9.2
9.2
closing delay
opening delay
With RC module
opening delay
DC
closing delay
opening delay
Integrated protection circuitopening delay
With diode
opening delay
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
[ms]
15…40
15…25
15…25
18…40
6…12
8…12
35…50
15…30
10…60
10…60
40…70
7…15
14…20
70…95
15…30
10…60
10…60
40…70
7…15
17…23
80…125
15…30
10…60
10…60
50…80
7…15
17…23
80…125
DC control
Pick-up and Holding Power
50 Hz, 60 Hz, 50/60 Hz
DC control
Switching Delay
AC
➊
➋
➌
➍
0.85…1.1
0.3…0.6
0.8…1.1
0.1…0.6
Pozidriv No. 2 / Blade No. 3 screw
Pozidriv No. 2 / Blade No. 4 screw
Hexagonal socket screw
Hexagonal screw
Product Selection - Page 4-10
4-46
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
100-C, 100S-C
43
60
CAB6
72
➋
85
-85
-105
➌
-105-EI
-140(-EI)
➍
-170-EI
-210-EI
-250-EI
-300-EI
➍
➍
2.5 … 16
2.5 … 10
2.5 … 35
2.5 … 25
—
—
—
—
—
—
2.5 … 25
2.5 … 15
2.5 … 50
2.5 … 35
—
—
—
—
—
—
—
20
25
30
—
—
10
12.5
15
—
—
2x5
2x5
2x6
4
—
—
6.1
8.3
10.5
1.5 … 3.5
14 … 6
—
13 … 31
2…6
14 … 2
—
18 … 52
8…10
6…2/0
CAB6-105-HU ➌
70…90
CAB6-HB1 ➌
10…12
6…250 MCM
CAB6-170-HU ➌
90…110
CAB6-HB2 ➌
16
8…600 MCM
825-ML630 / CA 6-420-HU ➌
130…150
➏ CAB6-HB3 ➌
—
—
16 … 35
16 … 70
➎ 16 … 35
➎ 16 … 95
25 … 240 ➐
25 … 240
—
—
16 … 50
16 … 95
➎ 16 … 50
➎ 16 … 120
25 … 300
25 … 300
—
—
16
3…9
3 … 12
20
3…9
3 … 14
25
4 … 20
4 … 20
—
—
—
—
—
—
—
—
8 … 10
No. 6 … 1 / 0 AWG
No. 6 … 3 / 0 AWG
70 … 90
10 … 12
No. 6 … 1 / 0 AWG
No. 6 AWG … 250 MCM
90 … 110
20 … 25
No. 4 AWG … 600 MCM
No. 4 AWG … 600 MCM
180 … 220
100-C, 100S-C
43
60
72
0.85 ….1.1
0.3 …0.6
0.8 …1.1
0.1 …0.6
➎
➏
➐
➑
-420-EI
CAB6
85
-85
-105/-140
0.85 …1.1
0.3 …0.6
0.85 …1.1
0.3 …0.6
-105-EI
-140-EI
-170-EI
-210-EI
-250-EI
-300-EI
-420-EI
0.85 …1.1
0.3 …0.5
0.85 …1.1
0.3 …0.5
130/90
10/3.2
10.1
10.1
200/110
16/4.5
200
4.5
650/310
50/10
540
8
370/243 ➑
12/6
190 ➑
6
590/355 ➑
15/7
375 ➑
7
15…30
10…60
10…60
50…80
7…15
17…23
80…125
20…40
10…60
10…60
20…40
—
≤ 220 V 20…35
> 220 V 80…125
20…47
6…12
9…18
27…47
12…20
12…20
—
75…90
30…60
—
75…90
30…60
—
—
75…90
30…60
—
75…90
30…60
—
—
With CT(A)B6-150 / 200 min. 25 mm2
CAB6-HB3 not for use with CEFB1-41 / 42 and 825-MCM630 in preparation
25 … 95 mm2 with sleeve per DIN 46228
Electronic coil drives are controlled for minimizing performance, but this control may shortly require (< 1ms) peak load when attracting.This must
be taken into account for the dimensioning of supply devices, all-or-nothing relays and cross-sections of coil supply lines. Please contact your
nearest Rockwell Automation sales office for detailed information
Product Selection - Page 4-10
Rockwell Automation
4-47
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Auxiliary Contacts and Auxiliary Contact Blocks
Auxiliary contact for 100-M
Switching of AC Loads
AC-12 Ith
Auxiliary contact for 100-C, 100S-C
Internal
Blocks
Internal
Front-mounted Side-mounted
Auxiliary contact for CAB6
Conventional
Electronically
compatible
0.1
at 250 V
at 40 °C
at 60 °C
[A]
[A]
16
12
10
6
25
20
10
6
10
6
16
12
24 V
42 / 48 V
110 V
230 V
240 V
400 V
415 V
500 V
690 V
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[A]
—
—
—
6
5
2.5
2
1.25
—
—
—
—
2
2
1
1
0.6
—
10
10
10
10
10
6
5
2.5
1
6
6
6
5.5
5
3
2.5
1.6
1
3
3
3
3
3
2
2
1.6
0.75
—
—
—
5.5
5
3
2.5
1.6
1
6
4
0.6
0.2
0.08
6
2
0.6
0.2
0.08
12
9
3.5
0.55
0.2
12
9
3.5
0.55
0.2
6
3.2
0.45
0.18
0.1
16
9
3.5
0.55
0.2
—
—
—
—
—
4
2.5
0.4
0.12
0.05
4
1.2
0.4
0.12
0.05
9
5
2
0.4
0.16
9
5
2
0.4
0.16
2
1.6
.3
0.12
0.05
9
5
2
0.4
0.16
—
—
—
—
—
5
0.6
0.45
0.25
0.04
2
0.6
0.45
0.1
0.04
5
2
0.7
0.25
0.12
5
2
0.7
0.25
0.12
3
1.5
0.6
0.3
0.2
5
2
0.7
0.25
0.12
AC-15 at rated voltage of
4
Switching of DC Loads
DC-12 L/R< 1 ms resistive loads at
24 VDC
[A]
48 VDC
[A]
110 VDC
[A]
220 VDC
[A]
440 VDC
[A]
DC-14 L/R< 15 ms inductive loads with economy
resistor in series at
24 VDC
[A]
48 VDC
[A]
110 VDC
[A]
220 VDC
[A]
440 VDC
[A]
DC-13 switching electromagnets at
24 VDC
[A]
48 VDC
[A]
110 VDC
[A]
220 VDC
[A]
440 VDC
[A]
Fuse gG
Short-circuit protection with no
Welding of contacts per IEC 947-5
[A]
[A]
16
10
10
10
10
16
—
10
10
10
10
16
—
5
1➊
max. 600
10 General
purpose
Heavy pilot duty
(A 600)
max. 600
Standard pilot
duty (P 600)
max. 250
between load
and auxiliary
circuit 250 V
5
5
5
max. 600
between load and auxiliary
circuit 500 V
5
[A]
10 General purpose
Switching capacity
AC
[A]
Heavy pilot duty (A 600)
A 600
Rated voltage
DC
[V]
max. 600
max. 600
[A]
Light pilot duty (Q 600)
Switching capacity
5
max. 600
40 °C
Continuous rating
(1 … 100 mA)
at
3 … 125 V
16
Safe isolation
Min. Short-circuit switching capacity 17 V DIN 19240
Auxiliary contacts
[mA]
Load Carrying Capacity per UL/CSA
Rated voltage
AC
[V]
(1 … 100 mA)
at
3 … 125 V
10
P 600
10
10
Q 600
0.1
0.1
max. 250
0.1
➊ Only with CAB6-P2-B11 and CAB6-P3-B11
Product Selection - Page 4-10
4-48
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
General
100-M
100-C, 100S-C
CAB6
09 … 85
-85 … 420-EI
500
600
690
600
1000
600
8
8
12
230, 240, 400, 415, 500
24, 48, 110, 220, 440
Class «B» per IEC 85
115, 230, 400, 500, 690
24, 48, 110, 220, 440
Class «F» per IEC 85
AC 50/60 Hz, DC
AC 50/60 Hz, DC
230, 240, 400, 415, 500, 690, 1000
24, 48, 110, 220, 440
Class «B» per VDE 0660,
Table 22
AC 50 Hz, 50/60 Hz, DC
05 … 09
12
Rated Isolation Voltage Ui
IEC, AS, BS, SEV, VDE 0660
per UL, NEMA, CSA, EEMAC
Rated Impulse Voltage Withstand Uimp
Rated Voltage Ue
AC
50/60 Hz
DC
Insulation Class of the Coil
Rated coil frequency
Ambient Temperature
Storage
Operation at rated voltage
at 70 °C
Climatic Withstand
Max. Altitude of Installation Site
Protection Class
Single contactor cover
Contactor with frame terminal block
Auxiliary contact
Protection against Accidental Contact
Resistance to Shock
Resistance to Vibration
Positively Guided Contacts per SUVA
Standards
Approvals
[V]
[V]
[kV]
[V]
[V]
[°C]
[°C]
[m]
-55 … +80
-25 … +60
-55 …+80
-25 …+60
15 % current reduction against 60 °C values
IEC 68-2
2000 NN, per IEC 947-4
IP2X (in connected state)
IEC 68-2
2000 NN, per IEC 947-4
IP2X
—
—
—
Finger and back-of-hand proof
per VDE 0106, part 100
IEC 68-2
IEC 68-2
Contactor contacts among each other.
Auxiliary contact block contacts next to
each other.
But not between contactor and auxiliary
contact block.
IEC 60947; EN 60947; UL 508;
CSA 22.2. No. 14
CE, UL Listed, CSA,
Germanischer Lloyd, Bureau
CE,
Veritas, Lloyd’s Register of
UL Listed,
Shipping,
CSA,
Maritime Register of
Shipping
-40 …+80
-25 …+60
Finger and back-of-hand proof
per VDE 0106, part 100
IEC 68-2
IEC 68-2
Restricted guidance guarantees without
restrictions from contactor to auxiliary
contact and auxiliary contact to
contactor.
No restricted guidance 100-FL, 100-FPT
IEC 60947; EN 60947; UL 508;
CSA 22.2. No. 14
CE, UL Listed, CSA, RINA,
Bureau Veritas, Maritime Register of
Shipping, American Bureau of Shipping,
Germanischer Lloyd, Lloyd’s Register of
Shipping,
Wershe Veritas in preparation
IEC 68-2
2000 NN, per IEC 947-4
IP00 IEC 529 / DIN 40 050
IP10 IEC 529 / DIN 40 050
IP20 IEC 529 / DIN 40 050
IP20 IEC 529 / DIN 40 050
Finger and back-of-hand proof
per VDE 0106, part 100
IEC 68-2
IEC 68-2
—
IEC 60947; EN 60947; UL 508;
CSA 22.2. No. 14
CE, UL Listed, CSA
Product Selection - Page 4-10
Rockwell Automation
4-49
4
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
CAB6-85
CAB6-105(-EI)
CAB6-140(-EI)
CAB6-170-EI
CAB6-210-EI
CAB6-250-EI
CAB6-300-EI
CAB6-420-EI
100-C60/72/85
100-C30/37
100-C43
Bulletin 100-C, CAB6 Contactors
100-C09/12/16
100-C23
Heavy Duty Starting and Regular Short-time Operation
max. Starting time / Loading time [s]
100
4
10
1
10
100
1000
10000
Starting current / Short-time current [A]
Electrical Life
Bulletin 100-M, 100-C, 100S-C, CAB6 Contactors
L1
L1
L2
L3
N
PE
UC
L1
US
US
UC
21
S0
22
0
A1
1 2
3
13
13
13
S1
A2
2 4
6
14
S1
14
14
A2
A2
M1 3 AC
K1
N (L2)
14
1
0/1
T1 T2 T3
13
K1
K1
K1
K1
H1
A1
H1
A1
N (L2)
Impulse contact control
Continuous contact control
Utilisation categories
Switching conditions for verifying electrical life (number of operations under load) per IEC 947-4; -5.
Making
Test conditions
AC-1
AC-2
AC-3
AC-4
AC-15
Resistance furnaces:
Non-inductive or slightly inductive loads
Slip-ring motors:
Starting and reversing
Squirrel-cage motors:
Starting and stopping of running motors
Squirrel-cage motors:
Starting, reversing, stepping
Solenoids:
for contactors, valves, and lifting magnets
Ie Rated operating current
Ue Rated operating voltage
Ie ≤17 A
Ie > 17 A
Ie ≤ 17 A
Ie > 17 A
Breaking
I/Ie
U/Ue
cosϕ
Ic/Ie
Ur/Ue
cosϕ
1
1
0.95
1
1
0.95
2.5
1
0.65
2.5
1
0.65
6
6
6
6
1
1
1
1
0.65
0.35
0.65
0.35
1
1
6
6
0.17
0.17
1
1
0.65
0.35
0.65
0.35
10
1
0.7
1
1
0.4
Ur Recovery voltage
I Making current
Ic
U
Breaking current
Off-load voltage
The following values are valid for the operating conditions defined in IEC 947-4 and utilisation categories AC-1...AC-4 at 400V, 50/60 Hz.
Product Selection - Page 4-10
4-50
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Electrical Life
100-M
Electrical Life; Ue = 400 / 415 VAC
AC-3 Switching of squirrel-cage motors while starting
AC-1 Non- or slightly inductive loads, resistance furnaces
10
Contact life [millions of operations]
4
1
100-M12
100-M09
0.1
100-M05
(AC-1)
0.01
1
10
100
Rated operating current Ie AC-2 [A]
(Dashed curves - - - - AC-1 only, open)
100-M
Electrical Life; Ue = 400 / 415 VAC
AC-4 Stepping of squirrel-cage motors
10
100-M09; 100-M12
Contact life [millions of operations]
100-M05
1
0.1
0.01
0.1
1
10
Rated operating current Ie [A]
Product Selection - Page 4-10
Rockwell Automation
4-51
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Electrical Life
100-C
C85
C72
C60
C43
C37
C30
1
0.1
1
10
100
Rated operating current Ie AC-1 [A]
100-C
C85
C72
C60
C30
C37
C43
C23
C16
AC-2 Stepping of slip-ring motors; Ue = 230…400…460 V
10
C12
Contact life [millions of operations]
4
Contact life [millions of operations]
10
C23
C16
C12
C09
AC-1 40° C Non- or slightly inductive loads, resistance furnaces; Ue = 230…690 V
C09
1
0.1
1
10
100
Rated operating current Ie AC-2 [A]
Product Selection - Page 4-10
4-52
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Electrical Life
100-C
C85
C72
C60
C43
C37
C30
C23
C16
C12
C09
AC-3 Switching of squirrel-cage motors while starting; Ue = 230…400…460 V
10
Contact life [millions of operations]
4
1
0.1
1
10
100
Rated operating current Ie AC-3 [A]
100-C
Contact life [millions of operations]
C85
C72
C60
C43
C37
C30
C23
C16
10
C12
C09
AC-3 Switching of squirrel-cage motors while starting; Ue = 500…575 V
1
0.1
1
10
100
Rated operating current Ie AC-3 [A]
Product Selection - Page 4-10
Rockwell Automation
4-53
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Electrical Life
100-C
C85
C72
C60
C43
C37
C30
C23
C16
C12
C09
AC-3 Switching of squirrel-cage motors while starting; Ue = 690 V
10
Contact life [millions of operations]
4
1
0.1
1
10
100
Rated operating current Ie AC-3 [A]
100-C
AC-4 Stepping of squirrel-cage motors; Ue = 230…690 V
Contact life [millions of operations]
10
C85
C72
C60
C43
C37
C30
C23
C16
C12
C09
1
0.1
1
10
100
Rated operating current Ie AC-4 [A]
Product Selection - Page 4-10
4-54
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Electrical Life
100-C
C85
C72
C60
C43
C37
C30
C23
C16
C12
AC-3 90 % & AC-4 10 % Mixed operation of squirrel-cage motors; Ue = 230…400…460 V
10
4
Contact life [millions of operations]
C09
1
0.1
1
10
100
Rated operating current Ie AC-3 / AC-4 [A]
CAB6
Contact life [millions of operations]
-420-EI
-300-EI
-250-EI
-210-EI
-170-EI
-140-(EI)
10
-105-(EI)
-85
AC-3 Switching of squirrel-cage motors while starting
AC-1 Non- or slightly inductive loads, resistance furnaces; Ue = 400 V
1
(AC-1)
0.1
10
100
1000
Rated operating current Ie AC-3 [A]
(Dashed curves ------ AC-1 only, open)
Product Selection - Page 4-10
Rockwell Automation
4-55
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Electrical Life
CAB6
-420-EI
-300-EI
-210-EI
-250-EI
-140-(EI)
-170-EI
-85
-105-(EI)
AC-4 Stepping of squirrel-cage motors; Ue = 400 V
10
Contact life [millions of operations]
4
1
0.1
0.01
1
100
10
1000
Rated operating current Ie AC-4 [A]
CAB6
Contact life [millions of operations]
-420-EI
-300-EI
-250-EI
-210-EI
-170-EI
-140-(EI)
-105-(EI)
10
-85
AC-3 90 % & AC-4 10 % Mixed operation of squirrel-cage motors; Ue = 400 V
1
0.1
10
100
1000
Rated operating current Ie AC-3 / AC-4 [A]
Product Selection - Page 4-10
4-56
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Permissible Switching Rate
100-C
AC-1 40° C Non- or slightly inductive loads, resistance furnaces; Ue = 230…690 V
3000
C09/C12/C16/C23
Permissible switching rate [ops/h]
2500
4
C30/C37
2000
C43
1500
C60/C72/C85
1000
500
0
0
10
20
30
40
50
60
70
80
90
100
P/Pn [%]
100-C
AC-2 Stepping of slip-ring motors; Ue = 230…460 V
Permissible switching rate [ops/h]
10000
1000
C09/C12/C16
C23/C30/C37/C43
C60
C72
C85
100
0
10
20
30
40
50
60
70
80
90
100
P/Pn [%]
Product Selection - Page 4-10
Rockwell Automation
4-57
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Permissible Switching Rate
100-C
AC-3 Switching of squirrel-cage motors while starting; Ue = 230…460 V
Relative operating time 40 %, Starting time tA = 0.25 s
10000
Permissible switching rate [ops/h]
4
1000
C09/C12/C16
C23/C30/C37/C43
C60/C72/C85
100
0
10
20
30
40
50
60
70
80
90
100
P/Pn [%]
100-C
AC-4 Stepping of squirrel-cage motors; Ue = 230…460 V
Starting time tA = 0.25 s
Permissible switching rate [ops/h]
1000
C09
C12
C16
100
C23/C30
C37/C43/C60
C72
C85
10
0
10
20
30
40
50
60
70
80
90
100
P/Pn [%]
Product Selection - Page 4-10
4-58
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Permissible Switching Rate
CAB6
AC-3 Switching of squirrel-cage motors while starting
Relative operating time 40 %, Starting time tA = 0.25 s
10000
10
10
-170-EI
-140(-EI)
100
-105(-EI)
1000
-85
Permissible switching rate [ops/h]
4
100
1000
Rated operating current Ie [A]
CAB6
AC-3 Switching of squirrel-cage motors while starting
Relative operating time 40 %, Starting time tA = 1 s
-140-(EI)
-170-EI
-85
-105-(EI)
Permissible switching rate [ops/h]
10000
1000
100
10
10
100
1000
Rated operating current Ie [A]
Product Selection - Page 4-10
Rockwell Automation
4-59
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Specifications
Permissible Switching Rate
CAB6
AC-2, AC-4 Stepping of motors
Starting time tA = 0.25 s
10000
4
Permissible switching rate [ops/h]
short time
CAB6-140(-EI), CAB6-170(-EI)
CAB6-85, CAB6-105(-EI)
1000
100
10
10
100
Starting current IA [A]
1000
10000
CAB6
AC-2, AC-4 Stepping of motors
Starting time tA = 1 s
Permissible switching rate [ops/h]
10000
1000
CAB6-85, CAB6-105(-EI)
100
CAB6-140(-EI), CAB6-170(-EI)
short time
10
10
100
Starting current IA [A]
1000
10000
Product Selection - Page 4-10
4-60
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Dimensions
Bulletin 100-M
Dimensions in millimetres
Mounting Position
c2
c1
d2
23˚
c
23˚
˚
90
4
b1
b
d1
90
˚
ød
➊
a
a1
Type
a
a1
b
b1
c
c1
c2
ød
d1
d2
100-M
45
67
56
47
48
74
77
4
50
40
Contactor with …
[mm]
Mechanical interlock
Auxiliary contact block
Timer
a+a
c1
c2
a1
a+20
c2
c..+5
front-mounted
side-mounted
side-mounted
Neutral terminal
Suppressor module
Label holder
➊
➊ Mountable on 35 mm DIN Rail EN50 022
(Combined DIN/C Rail mounting not possible when
using mechanical latch or mechanical interlock)
Bulletin 100-C
4.6 (3/16)
➊
ø 4,6 (3/16)
66
48
(1-57/64)
132
(5-13/64)
50
4
(5/32)
(1-31/32)
➊ Prestamping for pilot lamp
ø 20.5
(13/16)
ø 25.5
(1)
23 (29/32)
187 (7-23/64)
175 (6-57/64)
➊
(2-19/32)
175 (6-57/64)
73.5
(2-57/64)
45
(1-25/32)
42
(1-21/32)
45
(1-25/32)
ø 25 (63/64)
90
(3-35/64)
Product Selection - Page 4-10
Rockwell Automation
4-61
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Dimensions
Bulletin 100-C
Dimensions are shown in millimetres and (inches)
Mounting Position
+...
c2
AC Control
25˚
11
d1
b
5˚
11
11
5˚
5˚
ød
4
Ë
DC Control
11
d2
a
c1
c
c3
+...
25˚
5˚
+...
25˚
11
5˚
Ê
+...
AC Control
Type
100-C09 … 100-C23
100-C30 … 100-C37
100-C43
100-C60 … 100-C85
a
b
c
c1
c2
c3
ød
d1
d2
45
(1- 25/32)
45
(1- 25/32)
54
(2- 1/8)
72
(2- 53/64)
81
(3- 3/16)
81
(3- 3/16)
81
(3- 3/16)
122
(4- 51/64)
80.5
(3- 11/64)
97.5
(4)
100.5
(4- 7/64)
117
(4- 49/64)
75.5
(3- 3/32)
92.6
(3- 49/64)
95.6
(3- 7/8)
111.5
(4- 35/64)
6
(1/4)
6.5
(17/64)
6.5
(17/64)
8.5
(21/64)
4.5
(3/16)
4.5
(3/16)
5
(13/64)
5.5
(7/32)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
4 pcs each 5.4
(4 pcs each 7/32)
60
(2- 23/64)
60
(2- 23/64)
60
(2- 23/64)
100
(3- 15/16)
35
(1- 25/64)
35
(1- 25/64)
45
(1- 25/32)
55
(2- 11/64)
➊
➊
➊
➊
DC Control
Type
100-C09Z … 100-C16Z
100-C23Z
100-C30Z … 100-C37Z
100-C43Z
100-C60Z … 100-C85Z
a
b
c
c1
c2
c3
ød
d1
d2
45
(1- 25/32)
45
(1- 25/32)
45
(1- 25/32)
54
(2- 1/8)
72
(2- 53/64)
81
(3- 3/16)
81
(3- 3/16)
81
(3- 3/16)
81
(3- 3/16)
122
(4- 51/64)
106.5
(4- 3/16)
123.5
(4- 55/64)
141.5
(5- 37/64)
144.5
(5- 11/16)
117
(4- 49/64)
101.5
(4)
119
(4- 43/64)
136.5
(5- 3/8)
140
(5- 33/64)
111.5
(4- 35/64)
6
(1/4)
6
(1/4)
6.5
(17/64)
6.5
(17/64)
8.5
(21/64)
4.5
(3/16)
4.5
(3/16)
4.5
(3/16)
5
(13/64)
5.5
(7/32)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
4 pcs each 5.4
(4 pcs each 7/32)
60
(2- 23/64)
60
(2- 23/64)
60
(2- 23/64)
60
(2- 23/64)
100
(3- 15/16)
35
(1- 25/64)
35
(1- 25/64)
35
(1- 25/64)
45
(1- 25/32)
55
(2- 11/64)
➊
➊
➊
➊
➊
Accessories
AC Control
DC Control
Contactor with …
[mm]
Auxiliary contact block, front-mounted
Auxiliary contact block, side-mounted
Pneumatic timing module
Solid-State timing module (100-ETA)
Solid-State timing module (100-ETB / 100-ETY)
Mechanical interlock
Mechanical latch
Interface
Suppressor module
➋ Marking with
2- or 4-pole
1- or 2-pole
on coil connection side
on coil connection side
side-mounted
on coil connection side
on coil connection side
sheets of labels
marking sheets with cover
label holder for System V4/V5
label holder for System Bul. 1492W
[inches]
[mm]
c/c1 + 39 c/c1 + 1- 37/64
a+9
a + 23/64
c/c1 + 58 c/c1 + 2- 23/64
b + 24
b + 15/16
b + 24
b + 15/16
a+9
a + 23/64
c/c1 + 61 c/c1 + 2- 31/64
b+9
b + 23/64
b+3
b + 1/8
+0
+0
+0
+0
+ 5.5
+ 7/32
+ 5.5
+ 7/32
[inches]
c/c1 + 39 c/c1 + 1- 37/64
a+9
a + 23/64
—
—
b + 24
b + 15/16
—
—
a+9
a + 23/64
—
—
—
—
b+3
b + 1/8
+0
+0
+0
+0
+ 5.5
+ 7/32
+ 5.5
+ 7/32
➊ Mountable on 35 mm DIN Rail EN 50 022
Product Selection - Page 4-10
4-62
Rockwell Automation
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Dimensions
Bulletin 100S-C
Dimensions are shown in millimetres and (inches)
Mounting Position
+...
c2
AC Control
ød
25˚
d1
b
11
5˚
5˚ 5˚
4
Ë
Ê
DC Control
25˚
25˚
5˚ 5˚
+...
d2
a
c3
c1
c
+...
AC Control
Type
100S-C09…100S-C23
100S-C30…100S-C37
100S-C43
100S-C60…100S-C85
a
b
c
c1
c2
c3
ød
d1
d2
45
(1- 25/32)
45
(1- 25/32)
54
(2- 1/8)
72
(2- 53/64)
81
(3- 3/16)
81
(3- 3/16)
81
(3- 3/16)
122
(4- 51/64)
119.5
(4-3/4)
136.5
(5-37/64)
139.5
(5-11/16)
156
(6-11/32)
114.5
(4-43/64)
131.6
(5-11/32)
134.6
(5-29/64)
150.5
(6-1/8)
6
(1/4)
6.5
(17/64)
6.5
(17/64)
8.5
(21/64)
4.5
(3/16)
4.5
(3/16)
5
(13/64)
5.5
(7/32)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
4 pcs each 5.4
(4 pcs each 7/32)
60
(2- 23/64)
60
(2- 23/64)
60
(2- 23/64)
100
(3- 15/16)
35
(1- 25/64)
35
(1- 25/64)
45
(1- 25/32)
55
(2- 11/64)
➊
➊
➊
➊
DC Control
Type
100S-C09Z…100S-C16Z
100S-C23Z
100S-C30Z…100S-C37Z
100S-C43Z
100S-C60D…100S-C85D
a
b
c
c1
c2
c3
ød
d1
d2
45
(1- 25/32)
45
(1- 25/32)
45
(1- 25/32)
54
(2- 1/8)
72
(2- 53/64)
81
(3- 3/16)
81
(3- 3/16)
81
(3- 3/16)
81
(3- 3/16)
122
(4- 51/64)
145.5
(5-49/64)
162.5
(6-7/16)
180.5
(7-5/32)
183.5
(7-17/64)
156
(6-11/32)
140.5
(5-37/64)
158
(6-1/4)
175.5
(6-61/64)
179
(7-3/32)
150.5
(6-1/8)
6
(1/4)
6
(1/4)
6.5
(17/64)
6.5
(17/64)
8.5
(21/64)
4.5
(3/16)
4.5
(3/16)
4.5
(3/16)
5
(13/64)
5.5
(7/32)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
2 pcs each 4.5
(2 pcs each 3/16)
4 pcs each 5.4
(4 pcs each 7/32)
60
(2- 23/64)
60
(2- 23/64)
60
(2- 23/64)
60
(2- 23/64)
100
(3- 15/16)
35
(1- 25/64)
35
(1- 25/64)
35
(1- 25/64)
45
(1- 25/32)
55
(2- 11/64)
➊
➊
➊
➊
➊
Accessories
AC C control
DC Control
Contactor with …
[mm]
Auxiliary contact block, side-mounted
Solid-state timing module (100-ETA)
Solid-state timing module (100-ETB / 100-ETY)
Mechanical interlock
Interface
Suppressor Module
➋ Marking with
1- or 2-pole
on coil connection side
on coil connection side
side-mounted
on coil connection side
on coil connection side
sheets of labels
marking sheets with cover
label holder for System V4/V5
label holder for System Bul. 1492W
a+9
b + 24
b + 24
a+9
b+9
b+3
+0
+0
+ 5.5
+ 5.5
[inches]
a + 23/64
b + 15/16
b + 15/16
a + 23/64
b + 23/64
b + 1/8
+0
+0
+ 7/32
+ 7/32
[mm]
a+9
b + 24
—
a+9
—
b+3
+0
+0
+ 5.5
+ 5.5
[inches]
a + 23/64
b + 15/16
—
a + 23/64
—
b + 1/8
+0
+0
+ 7/32
+ 7/32
➊ Mountable on 35 mm DIN Rail EN 50 022
Product Selection - Page 4-10
Rockwell Automation
4-63
Bulletin 100-M, 100-C, 104-C, 100S-C, 104S-C, CAB6
Contactors
Dimensions
Bulletin CAB6
Dimensions in millimetres
Mounting Position
e2
c1
e4
e1
øe
➊
11
5˚
11
5˚
e3
b
4
5˚
11
d1
25˚
ød
d2
c
a
Type
a
b
c
c1
ød
d1
d2
øe
e1
e2
e3
e4
CAB6-85, CAB6-105
120
170
156
110.5
5.2
145
100
M6
16
38.5
147
8
CAB6-105-EI…CAB6-170-EI,
CAB6-140
120
170
156
110.5
5.2
145
100
M8
20
39
160
10
CAB6-210-EI …CAB6-420-EI
155
205
180
110.5
6.5
180
130
M10
25
48
193
12.5
Contactor with …
[mm]
Auxiliary contact block
P1 + P2
+ P3, or + P4
a
a + each 13.5
Mechanical interlock
a+a
Terminal block
HB 1
HB 2
HB 3
HA 1
HA 2
HA 3
Suppressor module
b + each 7
b + each 7
b + each 8.5
b + each 20…40
b + each 15…40
b + each 11…50
Label holder
➊ No change of base dimensions with 1 or 2 auxiliary contact
blocks (P1, P2).
With 3 or 4 auxiliary contact blocks (P3, P4), add 13.5 mm each.
c.. + 5
Bulletin CAB6 Mounting Plates
50
M6
ød
d2
b
50
d1
Type
a
b
c
ød
d1
d2
[kg]
CAB6-105-PS
150
340
6
6.5
315
135
1
CAB6-105-PU
270
340
6
6.5
315
255
1.8
CAB6-105-PY
390
340
6
6.5
315
275
2.5
CAB6-250-PS
188
380
6
6.5
315
173
1.4
CAB6-250-PU
344
380
6
6.5
315
328.5
2.6
CAB6-250-PY
499
380
6
6.5
315
484
3.75
C
a
Product Selection - Page 4-10
4-64
Rockwell Automation
Bulletin 100-G
Contactors
4
Bulletin 100-G
Contactors
• 315 … 710 kW
(550 … 1200 A)
Table of Contents
Description
Page
Description
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
Specifications
Page
Performance Data / Characteristics . . . . . . . . . . . . . . . . . . . . 4-69
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-66
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-72
Standards and Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-74
Accessories
Electrical Life. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-75
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-67
Permissible Switching Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . 4-76
Renewal Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-68
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-78
Rockwell Automation
4-65
Bulletin 100-G
Contactors
Product Selection
4
AC, DC Control
AC-1
Switching of 3-phase Motors AC-2, AC-3
[kW] ➊
[A]
EN Basic Number
[A]
40 °C
230 V
400 V
500 V
690 V
230 V
400 V
500 V
690 V
N.O.
N.C.
760
1000
1100
1200
1350
160
220
280
335
400
315
400
500
600
710
400
500
630
750
850
500
630
710
900
1000
550
700
860
1000
1200
550
700
860
1000
1200
550
700
860
1000
1200
500
630
700
860
1000
2
2
2
2➋
2➋
2
2
2
2
2
Cat. No.
PQ
100-G550⊗22
100-G700⊗22
100-G860⊗22
100-G1000⊗12
100-G1200⊗12
1
➋ 1 auxiliary contact (1 N.O. contact used in control circuit)
⊗ Voltage Suffix Code
For Use with
100-G550…100-G860
100-110 V 110-120 V 200-220 V 220-240 V 345-380 V 380-415 V 400-440 V 440-480 V
50/60 Hz
DC
For Use with
100-G1000…100-G1200
Price Adder for:
Special control voltages
50/60 Hz
DC
—
KD
KD
—
—
KF
KF
—
—
KN
KN
—
—
KB
KB
—
110-115 V
110 V
200-230 V
220 V
240 V
380-400 V
440 V
KD
—
—
ZD
KF
—
—
ZA
KA
—
KN
—
KB
—
Type
Available Control Voltages
No Surcharge
100-G550…100-G860
100-G1000, 100-G1200
24…600 V 50/60 Hz, 24…440 VDC
48…600 V 50/60 Hz, 48…440 VDC
> 25 pieces
➊ Power ratings: Preferred values according to IEC 60072-1
PQ = Package Quantity
Accessories - Page 4-67
Specifications - Page 4-69
Dimensions - Page 4-78
4-66
Rockwell Automation
Bulletin 100-G
Contactors
Accessories
Modules
Description
For Use with
Cat. No.
PQ
Auxiliary Contact Blocks
Up to 2 auxiliary contact blocks per contactor.
With the EF22 auxiliary switch block, the switching point of
the normally closed contact in relation to the main contacts
can be altered. See instructions included with the auxiliary
contact block.
mounted between
T1 and T2
mounted between
T2 and T3
13 21 31 43
53 61 71 83
14 22 32 44
54 62 72 84
1
100-EF22
100-G550…100-G860
Up to 4 auxiliary contact blocks per contactor.
1 make + 1 break
100-G1000, 100-G1200
1 make + 1 late break
Fourth Main Contact Pole
Left- or right-side mountable
100-G550
Ith AC-1 500 A
100-G700, 100-G860
100-NP500-5
100-NP500-6
100-G700, 100-G860
Ith AC-1 900 A
100-G1000, 100-G1200
100-NP1000-6
100-NP1000-7
4
100-EB11
100-EB11DC
1
Mechanical Latch
Mechanical life: 0.5 million operations
Direct and impulse contact control 100-G550
Direct and impulse contact control 100-G700, 100-G860
100-FLAM5⊗
100-FLAM6⊗
1
100-MC00-5H
100-G550 / 100-G550
100-G550 / 100-G700,
100-G860
Mechanical Interlock
The interlocks are delivered factory-mounted
100-G700, 100-G860 /
100-G700, 100-G860
100-G700, 100-G860 /
for 2 contactors mounted side by side 100-G1000, 100-G1200
100-MC00-56H
100-MC00-6H
1
100-MC00-67H
100-G1000, 100-G1200 /
100-G1000, 100-G1200
100-MC00-7H
100-G550 / 100-G550
100-G550 / 100-G700,
100-G860
100-G700, 100-G860 /
for 2 contactors stacked vertically 100-G700, 100-G860
100-G700, 100-G860 /
100-G1000, 100-G1200
100-MC00-5V
100-MC00-56V
100-MC00-6V
1
100-MC00-67V
100-G1000, 100-G1200 / 100G1000, 100-G1200
100-MC00-7V
⊗ Voltage Suffix Code
For Use with
100-G550…100-G1200
Price Adder for:
Special control voltages
50/60 Hz
110-120 V
220-240 V
380-415 V
440-480 V
KD
KF
KN
KB
Type
Available Control Voltages
No Surcharge
100-FLAM
12…550 V 50/60 Hz upon request
> 25 pieces
PQ = Package Quantity
Product Selection - Page 4-66
Rockwell Automation
4-67
Bulletin 100-G
Contactors
Accessories
Renewal Parts
Description
For Use with
Cat. No.
PQ
100-AC550
100-G550
Arc Chambers for Contactors
For 3 poles
1
4
100-G700, 100-G860
100-AC860
100-G1000
100-AC1000
For 1 pole
1
Main Contacts for Contactors
Set for 1 pole
100-G1200
100-AC1200
100-G550
100-CP550
100-G700
100-CP700
100-G860
100-CP860
100-G1000
100-CP1000
100-G1200
100-CP1200
1
Coils and Supply Modules for Contactors
Only available as renewal part
100-G550
100-G700…100-G860
100-G1000…100-G1200
Coils ➌
AC/DC control
see Table
below
1
Supply Module
AC/DC control
100-G550
100-G700…100-G860
100-G1000…100-G1200
see Table
below
Voltage Suffix Codes
100-G
AC
Standard
Control
Voltages
50/60 Hz
110…120 V
220…240 V
380…415 V
440…480 V
100-G550
DC
Standard
Control
Voltages
AC / DC
Coil
Code
100…110 V
200…220 V
345…380 V
400…440 V
KD
KF
KN
KB
Coil
➌
Cat. No.
TX734
TX747
TX779
TX780
Supply
module
Cat. No.
TXS734
TXS747
TXS779
TXS780
100-G700…
100-G860
Coil
➌
Cat. No.
TY734
TY747
TY779
TY780
Supply
module
Cat. No.
TYS734
TYS747
TYS779
TYS780
PQ
1
AC
Standard
Control
Voltages
50/60 Hz
110…115 V
220…230 V
380…400 V
440 V
AC /
DC
Coil
Code
KD
KF
KN
KB
100-G1000… 100G1200
Coil
➌
Cat. No.
TZ734
TZ747
TZ779
TZ780
Supply
module
Cat. No.
TZS734
TZS747
TZS779
TZS780
PQ
1
➌ Coils sold in pairs
Price Adder for:
Special control voltages
Type
Available Control Voltages
No Surcharge
100-G550…100-G860
100-G1000, 100-G1200
24…600 V 50/60 Hz, 24…440 VDC
48…600 V 50/60 Hz, 48…440 VDC
>25 pieces
PQ = Package Quantity
Product Selection - Page 4-66
4-68
Rockwell Automation
Bulletin 100-G
Contactors
Specifications
IEC Performance Data
100-G550
100-G700
100-G860
100-G1000
100-G1200
AC-1, Three-phase Switching
Ambient temperature 40 °C
Ie
Ambient temperature 60 °C
Ie
≤ 690 V
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
[A]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
760
303
316
527
546
658
908
1 316
1 000
398
416
693
719
866
1 195
1 732
1 100
438
457
762
791
953
1 315
1 905
1 200
478
499
831
863
1 039
1 434
—
1 350
538
561
935
970
1 169
1 613
—
≤ 690 V
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
[A]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
605
241
251
419
435
524
723
1 048
800
319
333
554
575
693
956
1 386
870
347
362
603
625
753
1 040
1 507
960
382
399
665
690
831
1 147
—
1 085
432
451
752
780
940
1 297
—
[A]
520
700
810
—
1 215
[A]
[A]
[A]
[A]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
550
550
550
500
160
185
315
315
400
500
700
700
700
630
220
220
400
425
500
630
860
860
860
700
280
300
500
530
630
710
1 000
1 000
1 000
860
335
335
600
630
750
900
1 200
1 200
1 200
1 000
400
400
710
750
850
1 000
[A]
[A]
[kW]
[kW]
[kW]
[kW]
140
140
45
47
78
81
180
180
57
60
101
105
210
210
67
70
118
122
260
260
83
87
146
151
300
300
97
101
170
176
[A]
[A]
[kW]
[kW]
[kW]
[kW]
360
350
116
111
198
206
430
420
139
151
238
247
520
520
170
177
295
300
(630)
(630)
(205)
(214)
(357)
(359)
(700)
(700)
(228)
(245)
(414)
(424)
[A]
[A]
[A]
[A]
[HP]
[HP]
[HP]
[HP]
414
360
414
336
150
150
350
350
552
602
590
472
200
250
500
500
692
722
708
576
250
300
600
600
—
—
—
—
—
—
—
—
1 185
1 130
1 062
864
450
450
900
900
Constant Current - UL/CSA
General Purpose Rating 40 °C
Switching of 3-phase Motors
AC-2, AC-3, AC-4
230/240 V
400/415 V
500 V
690 V
230 V ➋
240 V ➋
400 V ➋
415 V ➋
500 V ➋
690 V ➋
AC-4 at 200 000 operations
230/240 V
400/415 V
230 V
240 V
400 V
415 V
AC-4, Squirrel-cage motors with reversing
and jogging at 20 000 (25 000), operations
230/240 V
400/415 V ➊
230 V
240 V
400 V
415 V
Switching of 3-phase Motors - UL/CSA
60 Hz/60 °C
200 V
230 V
460 V
575 V
200 V
230 V
460 V
575 V
4
➊ At rated voltage 415V and rated current: Life span -25 %
➋ Power ratings: Preferred values according to IEC 60072-1
Product Selection - Page 4-66
Rockwell Automation
4-69
Bulletin 100-G
Contactors
Specifications
IEC Performance Data
Rated making capacity
AC-4
Ie
100-G550
100-G700
100-G860
100-G1000
100-G1200
≤ 415 V
500 V
690 V
[A]
[A]
[A]
5 500
5 500
5 000
7 000
7 000
6 300
8 600
8 600
7 000
10 000
10 000
8 600
12 000
12 000
10 300
≤ 240 V
400 V
415 V
500 V
690 V
[A]
[A]
[A]
[A]
[A]
5 500
4 500
4 500
4 500
4 500
7 000
5 600
5 600
5 600
5 600
8 000
6 900
6 900
6 900
6 000
8 000
8 000
8 000
8 000
6 900
9 600
9 600
9 600
9 600
8 000
≤ 500 V
690 V
230 V
240 V
400 V
415 V
500 V
690 V
1 000 V
[A]
[A]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
[kW]
953
831
310
324
540
561
705
883
615
1 212
1 091
395
412
717
745
897
1 138
866
1 490
1 195
485
507
882
915
1 102
1 247
970
1 732
1 490
565
589
1 025
1 088
1 309
1 554
—
2 078
1 732
677
707
1 250
1 278
1 538
2 078
—
230 V
[A]
460 V
[A]
575 V
[A]
Short-circuit Protection of Contactors
without Overload Relay
Fuse gG (aM) Type «1» coordination
per IEC 947-4-1
500 V
[A]
690 V
[A]
Switching of Three-phase Capacitor Motors
Inductivity of dispatching between parallel
switched capacitors: min. 6 µH
Single capacitors 40 °C
230 V
[kVar]
240 V
[kVar]
400 V
[kVar]
415 V
[kVar]
500 V
[kVar]
690 V
[kVar]
55 °C
230 V
[kVar]
240 V
[kVar]
400 V
[kVar]
415 V
[kVar]
500 V
[kVar]
690 V
[kVar]
Control capacitors 40 °C
230 V
[kVar]
240 V
[kVar]
400 V
[kVar]
415 V
[kVar]
500 V
[kVar]
690 V
[kVar]
55 °C
230 V
[kVar]
240 V
[kVar]
400 V
[kVar]
415 V
[kVar]
500 V
[kVar]
690 V
[kVar]
250
600
600
450
800
800
500
1 000
1 000
650
1 300
1 500
750
1 500
1 500
(630)
800
1 000
1 000
1 250
(630)
800
1 000
1 000
1 000
180
200
320
350
450
580
150
170
280
300
360
500
180
200
320
350
450
580
150
170
280
300
360
500
220
250
400
430
520
700
180
200
330
360
420
580
220
250
400
430
520
700
180
200
330
360
420
580
250
300
450
500
600
800
220
260
400
450
540
720
250
300
450
500
600
800
220
260
400
450
540
720
290
325
500
550
660
875
275
300
460
500
600
800
290
325
500
550
660
875
275
300
460
500
600
800
330
360
575
630
750
1 000
325
350
550
600
720
950
330
360
575
630
750
1 000
325
350
550
600
720
950
Rated breaking capacity
AC-4
Ie
4
Star-Delta Starting
50 Hz
Star-Delta Starting
60 Hz
Product Selection - Page 4-66
4-70
Rockwell Automation
Bulletin 100-G
Contactors
Specifications
IEC Performance Data
Switching of DC Loads
Switching of non- or slightly inductive loads,
resistance furnaces DC-1 at 60 °C
1-pole
24/48 V
2 Poles in series
24/48 V
3 Poles in series
24/48 V
110 V
220 V
Shunt Motors
Starting, regenartive brake, reverse,
Jogging DC-3, 60 °C
3 Pole in Serie
24/48 V
Series-characteristic Motors
Starting, regenartive brake, reverse,
Jogging DC-5, 60 °C
3 Pole in Serie
24/48 V
Switching of Lamps
Electric discharge lamps AC-5a
Single compensated:
open
close
Incandescent lamps AC-5b
Electrical Lifespan
~ 100 000 operations
Switching of Transformers AC-6a
Switch-on peak load
Rated transformer current
100-G550
100-G700
100-G860
100-G1000
100-G1200
[A]
[A]
[A]
[A]
[A]
645
645
645
480
315
760
760
760
560
400
930
930
930
630
450
1 020
1 020
1 020
800
500
1 150
1 150
1 150
900
600
[A]
605
800
870
960
1 085
[A]
605
800
870
960
1 085
[A]
[A]
450
570
700
850
1 000
360
460
550
660
800
[A]
315
440
500
560
630
[A]
[kVA]
[kVA]
[kVA]
[kVA]
[kVA]]
259
248
248
225
389
517
330
315
315
284
495
660
405
390
390
315
608
810
470
450
450
450
700
945
570
540
540
540
850
1 130
[A]
[A]
[A]
[A]
[A]
[A]
[A]
[Min.]
5 500
5 500
4 400
3 800
2 300
1 300
850
60
7 000
7 000
5 600
5 000
2 800
1 800
1 150
60
8 000
8 000
6 900
6 000
3 400
2 000
1 350
60
10 000
10 000
8 000
7 400
4 000
2 300
1 600
60
12 000
12 000
9 600
8 500
4 800
2 700
1 900
60
[mΩ]
[W]
0.11
99
0.1
147
0.08
177
0.06
300
0.05
318
[W]
[W]
110
109
172
169
202
199
370
360
388
378
4
=n
Rated transformer current
n = 30
400 VAC
500 VAC
690 VAC
n = 20
n = 15
Short-time Withstand ICW, 60 °C
1s
4s
10 s
15 s
60 s
240 s
900 s
Minimum Cooling Time at Zero Current
Resistance and Power Dissipation
Main current circuit resistance
Power dissipation of all at Ie AC-3
Total power dissipation
AC control
at Ie AC-3
DC control
Product Selection - Page 4-66
Rockwell Automation
4-71
Bulletin 100-G
Contactors
Specifications
IEC Performance Data
100-G550
Lifespan
mechanical
AC control
DC control
AC-3 (400 V)
AC control
DC control
Weight
4
[Mio. operations]
[Mio. operations]
[Mio. operations]
[kg]
[kg]
100-G700
100-G860
100-G1000
100-G1200
5
5
1
1
0.6
13.8
26.4
28.4
50.3
5x50
8x50
(1) x ø15
10x50
53.4
Connections Main Contacts
Terminal type
Connections Contactor
Hole diameter
c
c
s
b
c
s
s
b
b max.
c max.
s max.
Ø max.
[mm2]
[mm]
6x40
[mm]
[mm]
[mm]
[mm]
50
60
60
60
60
25
25
25
25
25
2x5
2x5
2x6
2x6
2x8
12.5
13
15
2 x 13
2 x 13
b
Recommended torque
With terminal lug
Wire cross-section acc. to EC 60947-1
Wire cross-section acc. to UL/CSA
Auxiliary contact
Coils
Nm]
(1) x ø13
10x60
(2) x ø17
50
60
75
90
100-LG5
100-LG6
100-LG6
100-LG7
(2) x 35…300
(3) x 35…300
(3) x 35…300
(4) x 35…300
[mm2]
[AWG] (2) x No. 2…600 MCM (3) x No. 2…600 MCM (3) x No. 2…600 MCM (4) x No. 2…600 MCM
(2) x 4
[mm2]
(2) x 4
[mm2]
90
100-LG7
(4) x 35…300
(4) x No. 2…600 MCM
Product Selection - Page 4-66
4-72
Rockwell Automation
Bulletin 100-G
Contactors
Specifications
Control Circuits
100-G550
Operating Limits
AC- 50 Hz
pick-up
dropout
pick-up
dropout
pick-up
dropout
[x Us]
[x Us]
[x Us]
[x Us]
[x Us]
[x Us]
pick-up
holding
pick-up
holding
pick-up
holding
[VA]
[VA/W]
[VA/W]
[VA/W]
[W]
[W]
closing delay
opening delay
closing delay
opening delay
[ms]
[ms]
[ms]
[ms]
AC- 60 Hz
DC control
Pick-up and Holding Power
AC- 50 Hz
AC- 60 Hz
DC control
Switching Delay
AC
DC
100-G700
100-G860
100-G1000
100-G1200
0.85…1.1
0.2…0.5
0.15…0.5
0.3…0.6
0.85…1.1
0.2…0.5
0.15…0.5
0.3…0.6
0.85…1.1
0.2…0.5
0.15…0.5
0.3…0.6
800…950
9…11
800…950
9…11
700…850
8…10
1 350…1600
21…25
1 350…1 600
21…25
1 300…1 550
18…22
2400
70
2400
70
2100
60
50…100
20…50 ➊ / 150…200 / 500…1 000 ➋
50…100
20…50 ➊ / 150…200 / 500…1 000 ➋
4
50…100
25…50
50…100
25…50
➊ accelerated
➋ delayed
Product Selection - Page 4-66
Rockwell Automation
4-73
Bulletin 100-G
Contactors
Specifications
Auxiliary Contact Blocks
100-G550
Switching of AC Loads
AC-1
Ith
100-G700
100-G860
100-G1000
100-G1200
at 40 °C
at 60 °C
[A]
[A]
16
12
16
12
120 V
230 V
240 V
400 V
415 V
500 V
690 V
[A]
[A]
[A]
[A]
[A]
[A]
[A]
6
3
3
2
2
1.5
1
6
3
3
2
2
1.5
1
6
3
1
0.5
6
3
1
0.5
10
16
AC-15 at rated voltage of
4
Switching of DC Loads
DC-13 Switching of electromagnets at
24 VDC
[A]
48 VDC
[A]
110 VDC
[A]
220 VDC
[A]
Fuse
Short-circuit protection with no welding of contacts
according to IEC 947-5
Fuse gG
[A]
General
100-G550
Rated Isolation Voltage Ui
IEC, AS, BS, SEV, VDE 0660
UL/CSA
Testing Voltage
1 minute according to IEC 947-4
Rated Voltage Ue
AC 50/60 Hz
DC
Insulation Class of the Coil
Rated Coil Frequency
Ambient Temperature
Storage
Operation at rated current
Climatic Withstand
Site Altitude
Protection Class
Shock Protection
Certifications
Approvals
100-G700
100-G860
100-G1000
100-G1200
[V]
[V]
1 000
600
690
600
[V]
3 500
2 500
[V]
[V]
230, 240, 400, 415, 500, 690
[°C]
[°C]
[m]
230, 240, 400, 415, 500, 690
24, 48, 110, 220, 440
Class «B» according to VDE 0660, table 22
AC 50/60 Hz, DC
-40 …+80
-25 …+60
Damp alternating conditions cyclical, according to DIN 50 016 and 40 046, Part 38, IEC 68
2000 NN, according to IEC 947-1
IP00 IEC 529 / DIN 40 050
Finger- and back of hand proof according to VDE 0106, Part 100
IEC 947, CEI 17-2, 17-3; UTE NF C 63-110; BS 5424; VDE 0660-1; NEMA; ICS
CE, UL Listed,
CE, UL Listed, Lloyd’s Register of Shipping
CE, Lloyd’s Register of Shipping
Lloyd’s Register of Shipping
Product Selection - Page 4-66
4-74
Rockwell Automation
Bulletin 100-G
Contactors
Specifications
Electrical Life
100-G
AC-3 Switching of running three-phase motors
AC-1 Non or slightly inductive loads, resistance furnaces
10
Contact life [millions of operations]
4
0.1
100
100-G-1200
100-G-860
100-G-1000
100-G-700
100-G-550
1
(AC-1)
1000
10000
Rated operating current Ie AC-1 / AC-3 [A]
(Dashed curves - - - for AC-1 only, open)
1
100-G
AC-4 Stepping of squirrel-cage motors
10
0.1
0.001
10
100
1000
100-G-1200
100-G-860
100-G-1000
100-G-700
0.01
100-G-550
Contact life [millions of operations]
1
10000
Rated operating current Ie AC-4 [A]
Product Selection - Page 4-66
Rockwell Automation
4-75
Bulletin 100-G
Contactors
Specifications
Electrical Life
100-G
AC-3 90 % Switching of running motor
AC-4 Stepping
10
Contact life [millions of operations]
4
1
0.01
100
100-G-1200
100-G-860
100-G-1000
100-G-700
100-G-550
0.1
1000
10000
Rated operating current Ie AC-3 / AC-4 [A]
Permissible Switching Rate
100-G
Switching of running squirrel-cage motors (AC-3)
Relative running time 40 %, starting time tA = 0.25 s
1000
100-G-700
Permissible switching rate [operations/hour]
100-G-860
100-G-550
100-G-1000, 100G -1200
100-G-1000 short time
100
10
100
1000
10000
Rated operating current Ie [A]
Product Selection - Page 4-66
4-76
Rockwell Automation
Bulletin 100-G
Contactors
Specifications
Permissible Switching Rate
100-G
Switching of running squirrel-cage motors (AC-3)
Relative running time 40 %, starting time tA = 1 s
100-G-1000, 100G -1200
100-G-860
100-G-700
100-G-550
Permissible switching rate [operations/hour]
1000
4
100
100-G-1000 short time
10
100
1000
10000
Rated operating current Ie [A]
100-G
100-G-700, -860
100-G-1000, -1200
Permissible switching rate [operations/hour]
1000
100-G-550
Switching of starting motors (AC-2 and AC-4)
Starting time tED = 1 s (< tA)
100
100-G-1000
short time
10
100
1000
100-G-860
short time
10000
Starting current Ie [A]
Product Selection - Page 4-66
Rockwell Automation
4-77
Bulletin 100-G
Contactors
Dimensions
100-G
Dimensions [millimetres]
Mounting Position
25˚
25˚
25˚
25˚
c1
e2
➊
e1
øe
e3
ød
b1
b
e3
d1
4
d2
a
Type
100-G550
100-G700
100-G860
100-G1000
100-G1200
c
a
b
b1
c
c1
ød
d1
d2
øe
e1
e2
e3
220
280
280
334
334
258
307
361
490
490
228
277
325
434
434
225
291
291
345
345
164
203
203
231
231
9
11
11
13
13
220
280
280
380
380
110
175
175
120
120
12.5
13
15
2x13
2x13
40
50
50
50
60
79
101
101
100
100
—
—
—
40
40
Contactors with:
100-G
[mm]
Auxiliary contact block
mechanical interlock
a
side-by-side
stacked vertically
4th main pole
mechanical latch
100-G550/100-G550
100-G700, G860/100-G700, G860
100-G1000, G1200/100-G1000, G1200
100-G550/100-G700, G860
100-G700, G860/100-G1000, G1200
100-G550/100-G550
100-G700, G860/100-G700, G860
100-G1000, G1200/100-G000, G1200
100-G550/100-G700, G860
100-G700, G860/100-G1000, G1200
100-G550
100-G700, G860
100-G1000, G1200
100-G550
100-G700
100-G860
100-G1000, G1200
a+42+a
a+32+a
a+46+a
a+37+a
a+73+a
b+56 + b
b+100…200+b
b+230…280+b
b+100…200+b
b+230…280+b
a+74
a+68
a+76
b+59
b+64
b+37
a+30
➊ Insulation partition plate 100-G1200 (UL regulation)
Product Selection - Page 4-66
4-78
Rockwell Automation